Samba Preclin Samba 200. Product Presentation

Size: px
Start display at page:

Download "Samba Preclin Samba 200. Product Presentation"

Transcription

1 Samba Preclin Samba 200 Product Presentation

2 Samba Preclin 420/360 Transducer Ultra-miniature fiber optic pressure sensor no bigger than a grain of salt on a hair! Highly sophisticated, accurate, fast and sensitive instrument designed to measure pressure in gas or liquid. Constructed with patented state-of-the-art micro mechanic and fiber optic technology. A first-class tool for building knowledge and solving problems in numerous application areas. Samba Preclin moves science into new territories! 2

3 3 Samba Sensors Technology

4 The Sensor Sensor Low pressure 0.42mm High pressure 0.36mm Optical fiber 0.25mm 4

5 Measuring Hydrostatic Pressure Space filled with GAS or LIQUID Hydrostatic pressure 5

6 6 The Sensor on a Finger Tip

7 X-ray Visibility Radiopaque coating 0.40mm 7

8 Samba Products

9 Main Products Ultra-miniature optical pressure transducers in different versions. For preclinical and industrial use. Control units with analog and serial ports. Samba Data Collection software for PC. For research use. Not FDA approved 9

10 Preclinical Transducers Samba Preclin 420 LP Miniature optical pressure transducers for research in vitro and in vivo. Low pressure range (-50 to +350 mbar). Also with radiopaque coating. 4m long. Samba Preclin 420/360 MR Miniature optical pressure transducers for research in vitro and in vivo. Extra long for use in MRI facilities. Low and high pressure ranges. 10m long. Samba Preclin 360 HP Miniature optical pressure transducers for research in vitro and in vivo. Three high pressure ranges (-0.1 to 5 bar, to 10 bar, -0.1 to 17 bar). Also with radiopaque coating. 4m long. Protective sensor covers are available for special applications 10

11 Samba Preclin Transducer Pressure can be measured in very small cavities or directly in the tissue of small (or large) animals. The ultra-miniature size minimizes insertion trauma. Insensitive to EM radiation and RF fields (MRI scanner, microwaves etc). Direct measurements with very high precision are made at the sensor location. The transducer does not affect the measuring environment itself. Low risk no electricity or bio-hazardous material. Long transducer possible (up to 10m). 11

12 Samba 201 Control Unit One fiber-optic port Battery operation Internal memory Absolute or relative measurement Internal barometer 3.2 inch display USB 2.0, analog and RS-232 ports Analogue output: 0-5V Sampling frequency: 1 Hz 40 khz Resolution: 0.1 mbar (~1mm H 2 O) Numerical resolution: 15 bit Numerical res.: 0.1 mbar Operating temp.: C Size: 215x110x45mm (8.5x4.3x1.8 in) Weight 950g (2.1 lbs) 12

13 Samba 202 Control Unit Two fiber-optic ports Battery operation Internal memory Absolute or relative measurement Internal barometer 3.2 inch display USB 2.0, analog and RS-232 ports Analogue output: 0-5V Sampling frequency: 1 Hz 40 khz Resolution: 0.1 mbar (~1mm H2O) Numerical resolution: 15 bit Numerical res.: 0.1 mbar Operating temp.: C Size: 215x110x45mm (8.5x4.3x1.8 in) Weight 950g (2.1 lbs) 13

14 Fast and Simple Start-Up Procedure 1. Insert the Samba transducer The transducer is factory calibrated - No further calibration is needed! 2. Turn on your Samba 200 Control Unit Allow internal circuitry temperature to stabilize (1-2 minutes) 3. Set the zero baseline against ambient air pressure The transducer is factory calibrated - No further calibration is needed! Simply follow instructions on the screen ( ZERO or PREVIOUS ) 4. If needed set measurement rate, Absolute/Relative mode, pressure unit etc. or load pre-defined Profile 5. Connect to PC or Data Acquisition System (DAS) When connected calibrate DAS by pressing ANALOG CALIB. 6. Remove protective cover, apply sensor in object and start measuring! 14

15 Samba vs. Competition The Samba system 1. has a simple and fast start-up procedure (~3 min) just Plug n Play! 2. is factory calibrated and doesn t need further calibration, only an automatic zero baseline set against the atmospheric pressure. 3. is extremely fast (up to 40 khz data sampling rate) and can record high-speed trauma events, for example ICP events caused by collisions. 4. is fully MRI compatible and completely insensitive to any electromagnetic waves radio waves or electrical noise. Real-time measurements and simultaneous recording of both visual and physiological effects of for example a drug is possible. Gating (MRI scanner triggering) for improved MR image quality and movie sequences is also feasible. 5. can measure pressure both in gas and liquid, which allows a very broad use. 15

16 Examples of Applications

17 17 Inserting Transducer into a Mouse Heart

18 Monitoring Pressure in a Mouse Heart Right Ventricular Pressure also possible! Transducer insertion Am J Physiol Heart Circ Physiol, Vol. 285, pp. H2233-H2239,

19 19

20 20

21 21

22 Pulse Wave Analysis (PWA) PWA, i.e. the analysis of the pulse pressure wave, is a method for studying vascular stiffness PWA provides valuable information for the characterization of cardiovascular disease, atherosclerosis and endothelial function The analysis is preferably made on a number of pulse wave cycles selected from a specific time period 22

23 Parameters in Samba PWA Software Pdiast = end-diastolic pressure Psyst = inflection point in systole Paug = max pressure during entire cycle RRint = heart cycle length Tsyst = time between pdiast and psyst PP = paug pdiast Taix = time from pdiast to paug Aug = Paug Psyst AIx (augmentation index) = Aug/(Paug-Pdiast) Further parameters related to the Dicrotic Notch will be available in future software version 23

24 24 Transducer Introduction into Rat Tail Artery

25 Triggering the MR Scanner (Gating) Respiration Triggering point: Exhalation & min. diastolic blood pressure Pressure [mmhg] Sharper MR images 0.00 & movie sequences! Time [s] B. Bjelke, MD, PhD, Karolinska Institute, Sweden

26 Gating on Samba Signal (IBP) Image of rat heart MRI scanner triggered on rat tail IBP signal Advantages Improved image quality (less artifacts than ECG) Real-time IBP monitoring Volume & CO Movie sequences 26

27 27 MRI Movie Sequence

28 Intracranial Monitoring on a Rat Samba transducer 28

29 ICP in Fluid Percussion Model Intracranial Pressure Pressure [mbar] Water Pressure ,00 0,10 0,20 Time [s] Acta Neurochir Vol. 147, No. 7, pp ,

30 Rabbit CNS Trauma Model Eur J Neurosci. Vol. 21, No. 10, pp ,

31 Rabbit CNS Trauma Model Pressure [bar] Rot. acc.(rad/s^2) Time (s) Occipital lobe pressure transducer Parietotemporal lobe pressure transducer Rotational acceleration Eur J Neurosci. Vol. 21, No. 10, pp ,

32 Spinal Disc Measurements Proceedings SPIE 3570, 1998 Samba transducer inserted into disc via a cannula 32

33 33 Proceedings SPIE 3570, 1998

34 34 Urodynamic Investigation Transurethral introduction of transducer into bladder

35 Urodynamic Investigation Transurethral introduction of transducer into bladder Courtesy of Prof. Ulla Sillén, Dept. of Pediatrics Sahlgrenska University Hospital, Sweden 35

36 Airway Pressure Monitoring Endotracheal tube Samba sensor Ventilator pressure sensor 36

37 Pressure Measurement in Pediatric ETT Transducer inserted through tube into lower trachea Relative pressure [cmh2o] Samba Respiratory Samples [25 Hz] 37

38 Intra-folliclular Pressure (during open surgery) Time [sec] P Dahm-Kähler et al. Poster Läkarstämman,

39 Clinical Samba Projects 1. Urodynamic investigations 2. Respiratory pressures 3. Intracranial pressures 4. Intervertebral disc pressure (spinal surgery) 5. Cardiovascular blood pressures 6. Gastro-intestinal pressures 7. Intra-follicle pressure (gynecology) 39

40 Samba s unique offering High-precision pressure measurements can be performed where never before possible. New science and knowledge can be revealed leading to more publications. APPLICATION AREAS: - Heart and Circulation - Brain and Nervous System - Lungs and Breathing - Gastro-intestinal System - Kidney and Urinary System - Reproduction System - Muscles - Diseases like Cancers, Stroke, Spinal Disorders and more 40

41 Contact Harvard Apparatus, Ltd Fircroft Way, Edenbridge Kent TN8 6HE England United Kingdom Phone: (44) Fax: (44) Internet: 41

Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH

Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at Building a Simulink model for real-time

More information

SUMMARY. Additional Digital/Software filters are included in Chart and filter the data after it has been sampled and recorded by the PowerLab.

SUMMARY. Additional Digital/Software filters are included in Chart and filter the data after it has been sampled and recorded by the PowerLab. This technique note was compiled by ADInstruments Pty Ltd. It includes figures and tables from S.S. Young (2001): Computerized data acquisition and analysis for the life sciences. For further information

More information

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Introduction Direct measurement of arterial blood pressure is obtained via a peripheral

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

PRODUCT SHEET OUT1 SPECIFICATIONS

PRODUCT SHEET OUT1 SPECIFICATIONS OUT SERIES Headphones OUT2 BNC Output Adapter OUT1 High Fidelity Headphones OUT1A Ultra-Wide Frequency Response Headphones OUT3 see Stimulators OUT100 Monaural Headphone 40HP Monaural Headphones OUT101

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Michigan Adult Cardiac Protocols CARDIAC ARREST GENERAL. Date: May 31, 2012 Page 1 of 5

Michigan Adult Cardiac Protocols CARDIAC ARREST GENERAL. Date: May 31, 2012 Page 1 of 5 Date: May 31, 2012 Page 1 of 5 Cardiac Arrest General This protocol should be followed for all adult cardiac arrests. Medical cardiac arrest patients undergoing attempted resuscitation should not be transported

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

State-of-the-Art Technology in Cardiac CT

State-of-the-Art Technology in Cardiac CT 1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80

More information

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs Vital Signs: Assessment and Interpretation Elma I. LeDoux, MD, FACP, FACC Associate Professor of Medicine Vtial sign #1: PULSE Reflects heart rate (resting 60-90/min) Should be strong and regular Use 2

More information

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Technique and Safety of performing EEG/fMRI measurements by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Contents of the presentation Why recording simultaneous EEG and fmri?

More information

Hemodynamic Pressure and Volume Signals

Hemodynamic Pressure and Volume Signals Hemodynamic Pressure and Volume Signals PowerLab Systems, LabChart Software and Millar Mikro-Tip and Ventri-Cath Catheters Features & Benefits n Excellent signal frequency response n No motion artifact

More information

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display MEDICAL INTERNATIONAL RESEARCH Spirodoc One Touch Laboratory for respiratory analysis two functional modes: doctor and patient Spirometer with Touch Screen display Pulse Oximeter intelligent with on screen

More information

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19 Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and

More information

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully. 1 INTRODUCTION The UltraTec

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

Our Human Body On-site student activities Years 5 6

Our Human Body On-site student activities Years 5 6 Our Human Body On-site student activities Years 5 6 Our Human Body On-site student activities: Years 5-6 Student activity (and record) sheets have been developed with alternative themes for students to

More information

Nardalert S3 Non-Ionizing Radiation Monitor

Nardalert S3 Non-Ionizing Radiation Monitor Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP Now Powered by LightField FEATURES BENEFITS Back Illuminated CCD (248B) For highest sensitivity Front illuminated CCD (248F) Affordable technology for moderate light level applications Ultra low noise

More information

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions

More information

Electrocardiogram (ECG) Monitoring System using Bluetooth technology

Electrocardiogram (ECG) Monitoring System using Bluetooth technology Electrocardiogram (ECG) Monitoring System using Bluetooth technology Zarina Md Amin, Suryani Ilias, Zunuwanas Mohamad Department of Electrical Engineering, Polytechnic of Sultan Abdul Salahuddin Abdul

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

4 Scientific Publications of the. ^American Heart Association

4 Scientific Publications of the. ^American Heart Association 4 Scientific Publications of the ^ Technology Assessment Forum on Coronary Artery Bypass Surgery: Economic, Ethical and Social Issues Guest Editors: Michael Eliastam, M.D., M.PP Barbara Gastel, M.D., M.PH.

More information

Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill

Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill Objectives: Analyze the operation of sequential logic circuits. Understand the operation of digital counters.

More information

Anatomi & Fysiologi 060301. The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;

Anatomi & Fysiologi 060301. The cardiovascular system (chapter 20) The circulation system transports; What the heart can do; The cardiovascular system consists of; The cardiovascular system (chapter 20) Principles of Anatomy & Physiology 2009 Blood 2 separate pumps (heart) Many blood vessels with varying diameter and elasticity

More information

Wireless bedside Vital Signs monitoring unit

Wireless bedside Vital Signs monitoring unit Wireless bedside Vital Signs monitoring unit A. Trigo 1, J.P. Cunha 1,2, M.B.Cunha 1,2, William Xavier 1 and Nuno Silva Ferreira 1 1 IEETA Instituto de Engenharia Electrónica e Telemática de Aveiro 2 Departamento

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Rackmount Intelligent Pressure Scanners

Rackmount Intelligent Pressure Scanners Rackmount Intelligent Pressure Scanners NetScanner System 9816/98RK-1 FEATURES ±0.05% Accuracy 100 Hz EU Throughput Autonegotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol Pressure Ranges up to

More information

Surgery Support System as a Surgeon s Advanced Hand and Eye

Surgery Support System as a Surgeon s Advanced Hand and Eye Surgery Support System as a Surgeon s Advanced Hand and Eye 8 Surgery Support System as a Surgeon s Advanced Hand and Eye Kazutoshi Kan Michio Oikawa Takashi Azuma Shio Miyamoto OVERVIEW: A surgery support

More information

Making Simulation Easier. SimPad System. Laerdal Simulation Solutions. laerdal.com. laerdal.com

Making Simulation Easier. SimPad System. Laerdal Simulation Solutions. laerdal.com. laerdal.com Making Simulation Easier SimPad System TM Laerdal Simulation Solutions laerdal.com laerdal.com When simulation tools are easy to use, teaching becomes more effective Why simulation? While simulation is

More information

Section Two: Arterial Pressure Monitoring

Section Two: Arterial Pressure Monitoring Section Two: Arterial Pressure Monitoring Indications An arterial line is indicated for blood pressure monitoring for the patient with any medical or surgical condition that compromises cardiac output,

More information

Physiologic Monitoring Systems for Life Science Research. Discover the possibilities with DSI.

Physiologic Monitoring Systems for Life Science Research. Discover the possibilities with DSI. Physiologic Monitoring Systems for Life Science Research Discover the possibilities with DSI. Flexible Solutions for Research CARDIOVASCULAR arterial and left ventricular pressures, ECG, activity, pressure

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

Type-D EEG System for Regular EEG Clinic

Type-D EEG System for Regular EEG Clinic Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal

More information

«The compact and mobile testing device for ventilators.»

«The compact and mobile testing device for ventilators.» «The compact and mobile testing device for ventilators.» Developed for mobile use simple. compact. reliable. Simple operation CITREX is simple and intuitive to operate. The colour screen offers excellent

More information

How to design an insulin pump

How to design an insulin pump How to design an insulin pump Learn about the purpose of an insulin pump, its overall workings, and the requirements needed for its design as well as implementation. By Asha Ganesan Applications Engineer

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Equipment / Procedure: Filename: Assessor s name & date: Reviewer s name & date: Cosmed K4 2012.1201SOP_cosmed_K4 Richard Metcalfe, December 2012 Tom Nightingale, December

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Fiber Optic Distributed Temperature Sensor (B-DTS)

Fiber Optic Distributed Temperature Sensor (B-DTS) Fiber Optic Distributed Temperature Sensor (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com

More information

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Various Technics of Liquids and Solids Level Measurements. (Part 3) (Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,

More information

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD www.arexx.com.cn. Six-servo Robot Arm

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD www.arexx.com.cn. Six-servo Robot Arm Six-servo Robot Arm 1 1, Introduction 1.1, Function Briefing Servo robot, as the name suggests, is the six servo motor-driven robot arm. Since the arm has a few joints, we can imagine, our human arm, in

More information

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard. CardioCard System Product Specification and Sample Reports CardioCard PC-Based ECG CardioCard PC-Based Stress CardioCard PC-Based Holter Table Lorem of Contents Ipsum iii 1 i Table of Contents 1 Advanced

More information

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to. Heart Rate Sensor Heart Rate Sensor (Product No PC-3147) Pulse rate Range: 0 to 200 bpm Resolution: 1 bpm Waveform Range: -2000 to 2000 mv Resolution: 1 mv Introduction The Smart Q Heart Rate Sensor monitors

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care Sensors / Modules / Monitors Breath Gas Sensing and Monitoring For life supporting systems in intensive, emergency and ambulant care Your competent partner for breath gas sensing and monitoring EnviteC

More information

2161-1 - Page 1. Name: 1) Choose the disease that is most closely related to the given phrase. Questions 10 and 11 refer to the following:

2161-1 - Page 1. Name: 1) Choose the disease that is most closely related to the given phrase. Questions 10 and 11 refer to the following: Name: 2161-1 - Page 1 1) Choose the disease that is most closely related to the given phrase. a disease of the bone marrow characterized by uncontrolled production of white blood cells A) meningitis B)

More information

OxySense Gen III Operations Manual

OxySense Gen III Operations Manual OxySense Gen III Operations Manual OxySense GEN III 300 Series OxySense GEN III 5000 Series COMPLIES WITH ASTM 2714-08 OxySense, Inc. 13111 North Central Expressway, Suite 440 Dallas, Texas 75243 Phone

More information

DATA SHEET DVI - HDCP Extension Cable

DATA SHEET DVI - HDCP Extension Cable DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications

More information

Design of an Insulin Pump. Purpose of an Insulin Pump:

Design of an Insulin Pump. Purpose of an Insulin Pump: Design of an Insulin Pump Purpose of an Insulin Pump: Insulin is a hormone central to regulating carbohydrate and fat metabolism in the body. It is secreted regularly within the body and aids in converting

More information

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES Low power consumption: typically 0.4mA@3V with 50 measurements per second Power up/down function available through I 2 C interface SET/RESET

More information

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM SUMMARY HEMODYNAMIC MONITORING: FROM PRINCIPLES TO PRACTICE Michael L. Cheatham, MD, FACS, FCCM Director, Surgical Intensive Care Units Orlando Regional Medical Center Orlando, Florida Fluid-filled catheters

More information

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH28CS-12kV Hi Pot Tester Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:

More information

MECHINICAL VENTILATION S. Kache, MD

MECHINICAL VENTILATION S. Kache, MD MECHINICAL VENTILATION S. Kache, MD Spontaneous respiration vs. Mechanical ventilation Natural spontaneous ventilation occurs when the respiratory muscles, diaphragm and intercostal muscles pull on the

More information

5/30/2014 OBJECTIVES THE ROLE OF A RESPIRATORY THERAPIST IN THE DELIVERY ROOM. Disclosure

5/30/2014 OBJECTIVES THE ROLE OF A RESPIRATORY THERAPIST IN THE DELIVERY ROOM. Disclosure THE ROLE OF A RESPIRATORY THERAPIST IN THE DELIVERY ROOM Ona Fofah, MD FAAP Assistant Professor of Pediatrics Director, Division of Neonatology Department of Pediatrics Rutgers- NJMS, Newark OBJECTIVES

More information

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7 focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V01.3-2014-7 Thank you for purchasing our product. Please read this manual carefully before operation your set and retain it for future reference. FT55-P10

More information

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning. GRADE 11F: Biology 3 Human gas exchange system and health UNIT 11FB.3 9 hours About this unit This unit is the third of six units on biology for Grade 11 foundation. The unit is designed to guide your

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Datalogger DL/N 70 Version: 28.03.2012

Datalogger DL/N 70 Version: 28.03.2012 Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

Measuring Laser Power and Energy Output

Measuring Laser Power and Energy Output Measuring Laser Power and Energy Output Introduction The most fundamental method of checking the performance of a laser is to measure its power or energy output. Laser output directly affects a laser s

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

5,000 lb Capacity. Wireless Communication Scale

5,000 lb Capacity. Wireless Communication Scale 5,000 lb Capacity Wireless Communication Scale Ready. Reliable. Right on the Money. Manufactured with superior quality and exceptional value, Mitsubishi forklift trucks are equipped with extensive dealer

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

High speed infrared camera for contactless temperature measurement on rotating tires

High speed infrared camera for contactless temperature measurement on rotating tires DIAS Infrared GmbH Publications No. 9 1 High speed infrared camera for contactless temperature measurement on rotating tires Helmut Budzier, Dresden University of Technology, Institute for Solid-State

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

Ultrasonic Wave Propagation Review

Ultrasonic Wave Propagation Review Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic

More information

VITALMONITOR SOFTWARE FOR PATIENT MONITORING

VITALMONITOR SOFTWARE FOR PATIENT MONITORING VITALMONITOR SOFTWARE FOR PATIENT MONITORING A USERS GUIDE Version 1.102 March 2009-1 - USING THE VITALMONITOR SOFTWARE Section 2: Using the VitalMonitor Software... 4 The VitalMonitor and VitalStore programs...

More information

Android based Alcohol detection system using Bluetooth technology

Android based Alcohol detection system using Bluetooth technology For more Project details visit: http://www.projectsof8051.com/android-based-alcohol-detection-system-usingbluetooth-technology/ Code 1435 Project Title Android based Alcohol detection system using Bluetooth

More information

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter

More information

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators Technical Note: 9 Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators 1- Introduction The VALIDATOR, model TN-ID-60, is a compact, and stand-alone dosimetry

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Impact Uni-Vent 754 Portable Ventilator

Impact Uni-Vent 754 Portable Ventilator Impact Uni-Vent 754 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 754 Portable Ventilator is a portable electronically controlled,

More information

Investigating the Human Body On-site student activities: Years 7-8 Investigating the Human Body On-site student activities Years 7 8

Investigating the Human Body On-site student activities: Years 7-8 Investigating the Human Body On-site student activities Years 7 8 Investigating the Human Body On-site student activities Years 7 8 Student activity (and record) sheets have been developed with alternative themes for students to use as guides and focus material during

More information

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor

More information

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available

More information

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

3 rd Russian-Bavarian Conference on Bio-Medical Engineering 3 rd Russian-Bavarian Conference on Bio-Medical Engineering Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position Dipl.-Inform. Med. Christian Douniama Dipl.-Ing.

More information

2.24. Pump Controller 704. Data Sheet

2.24. Pump Controller 704. Data Sheet Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with

More information

Clinical Research Software for Intensive Care Monitoring

Clinical Research Software for Intensive Care Monitoring The past, the present and the future Clinical Research Software for Intensive Care Monitoring Dr Peter Smielewski Dept of Clinical Neurosciences University of Cambridge Disclosure ICM+ software is licensed

More information

Normal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network

Normal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network Normal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform display

More information

NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: sales@a-tech.ca; www.a-tech.ca

NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: sales@a-tech.ca; www.a-tech.ca Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC

More information

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.

More information

K-Type Thermocouple Sensor User s Guide

K-Type Thermocouple Sensor User s Guide K-Type Thermocouple Sensor User s Guide 1 TABLE OF CONTENTS: 1 INTRODUCTION... 2 2 TYPICAL APPLICATION:... 2 3 INSTALLATION RULES:... 2 3.1 Connecting the sensor to M1/MD4 data logger:... 2 3.2 Connecting

More information

VE464 ASSURING HIGH PRODUCTIVITY AND QUALITY FOR VIBROSEIS OPERATIONS. Ahead of the Curve SM

VE464 ASSURING HIGH PRODUCTIVITY AND QUALITY FOR VIBROSEIS OPERATIONS. Ahead of the Curve SM VE464 ASSURING HIGH PRODUCTIVITY AND QUALITY FOR VIBROSEIS OPERATIONS Ahead of the Curve SM VE464 For decades the VE416, followed by the VE432, have been the most advanced Vibrator Digital Control Systems

More information

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System IR-PRO Operation Guide IR-PRO Professional Infrared Code Capture System Introduction The IR-PRO is an infrared code capture system that is specifically designed for system integration professionals. Unlike

More information

Cosmed K4b2 User Guide

Cosmed K4b2 User Guide Cosmed K4b2 User Guide Initial Mains Set Up Connect up 6V power cable to unit and plug in Initial Set Up Power on the main unit (F) and warm up for 15 minutes Set Up Battery Charging Charge batteries during

More information

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you

More information

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application Edwards FloTrac Sensor & Edwards Vigileo Monitor Understanding Stroke Volume Variation and Its Clinical Application 1 Topics System Configuration Pulsus Paradoxes Reversed Pulsus Paradoxus What is Stroke

More information

Digital vs. Analogue Control Systems

Digital vs. Analogue Control Systems Digital vs. Analogue Control Systems Presented at the 2011 Annual Meeting of the American College of Medical Physics, Chattanooga, TN, May 1, 2011 Ivan A. Brezovich, PhD, Dept. of Rad Onc, Univ of Alabama

More information

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous

More information

PATIENT MONITORING SYSTEM

PATIENT MONITORING SYSTEM PATIENT MONITORING SYSTEM - Siddhiq Vaaraahi Embedded Ref : TiDC 2007 Date: 30-11-2007 Venue: The Leela Palace, Bangalore 1. What is Patient Monitoring 2. Why is it required 3. Where it is required CONTENTS

More information

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE NeuLog heart rate and pulse logger sensor NUL-208 The NeuLog pulse sensor can be used for any science experiment which requires a human heart rate or pulse measurement such as in the fields of Biology,

More information

PicoScope 6000A/B Series

PicoScope 6000A/B Series PicoScope 6000A/B Series PC Oscilloscopes User's Guide -1 PicoScope 6000A/B Series User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warnings 4 FCC

More information

Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back

Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back to the left atria from the left ventricle, blood is pumped

More information

EVAL-UFDC-1/UFDC-1M-16

EVAL-UFDC-1/UFDC-1M-16 Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1

More information

Regards from the Team at Rheology Solutions.

Regards from the Team at Rheology Solutions. Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained

More information

Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network

Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network Normal & Abnormal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform

More information