Business Customer Demarcation Information

Size: px
Start display at page:

Download "Business Customer Demarcation Information"

Transcription

1 Building Industry Consulting Service (BICS) Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business data customers and services. 1. What is a Demarcation Point? a. A Demarcation Point (Demarc) is the mutually agreed upon location between TELUS Communications Inc. and the building owner, at the time of the building construction that provides for the interconnection of TELUS Communications Inc. and customer facilities. The Demarcation Point is also referred to as the "Customer Connection Point" in the TELUS Communications Inc. Tariff. TELUS Network Service Facilities include facilities that connect TELUS Communications Inc.'s Central Office to the Network Interface at a residence, building or property. Customer facilities or distribution facilities include inside wire, raceways and housing required to place in building wire from the Demarcation Point and the customer's station apparatus or terminal equipment. Inside wire is terminated on Connecting Blocks. b. Provides Electrical Protection The Demarc panel includes Protectors: A device placed at the customer's premise on incoming network lines to protect against lightning and power surges. c. The panel is connected to a customer/builder provided #6 ground wire at the time of building entrance being provisioned. d. The "Building Industry Consulting Service" (BICS) standards, outlines the responsibilities of the customer/developer, prior to TELUS Communications Inc. providing Network Service, i.e. on private property up to the Demarcation Point. e. The BICS requirements are conditions of service, according to Canadian Electrical Code and Tariffs. 2. What does a TELUS provided Demarc include? a. Copper 1. Outside Copper Communications Cable 2. Termination Panel (see section 4 for pictures) Electrical Protection (all outside TELUS owned cables connected to the TELUS network will always have electrical protection). Connectivity to TELUS facilities from the Area s Central Office through this Customer Connection point. Page 1 of

2 b. Fibre 1. Outside fibre communications cable 2. Termination Panel, which include connectivity to TELUS facilities (see Section 4 for pictures). 3. Where is a Demarc located within a given premise? a. For all new installation, the location for the Demarc is called the Main Telephone Room (MTR) (unless a grandfathered location was mutually agreed to in an existing building, with reference to the statement in Section 1a of this document). b. It is typically the first point of entry access into the building by the outside telephone cable. c. It is where the main outside telephone cable is terminated onto a protection panel. d. The room used as the cross-connecting point of incoming cables from TELUS Communications Inc.'s Central Office and the in-building cable system. e. Often can be found: i. near the building s main power panel ii. in the building s furnace or utility room iii. for multi-tenant building, can be in a separate utility room having an outside entry iv. on high-rise building, usually on a basement level or main floor f. Voice Service Demarc is always the termination panel in the Main Telephone Room (MTR). g. Data Demarc is always the termination panel in the Main Telephone Room (MTR). TELUS can extend the inside wiring (copper and fibre) as requested by the customer to an alternate location. Time and charges will apply depending on the service being applied for. 3.1 Copper Demarcation Tariff Within the City of Edmonton The source for this portion of this document is TELUS Communications Inc. Tariff CRTC Non-Multi Dwelling Units Tariff Item 26.1 Multi Dwelling Units Tariff Item 26-A.1 Tariff Item 26.9 Tariff Item Outside the City of Edmonton (Alberta Province) The source for this portion of this document is TELUS Communications Inc. Tariff CRTC Tariff Item 25.1 Tariff Item 25.2 Page 2 of

3 Tariff Item 25.3 Tariff Item 25.4 In the Province of British Columbia The source document for this portion of this document is TELUS Communications (BC) Inc. Tariff CRTC Non-Multi Dwelling Units Tariff Item 97, A (1) Multi Dwelling Units Tariff Item 97, A (2) Tariff Item 97, A (3) Tariff Item 97, A (4) For further clarification on BICS regulations, please visit our website located at vices. 3.2 Point of Service vs. Demarcation Point for Terminating Equipment Purpose The purpose of this section is to identify the difference between the point of demarcation and the point of need for the customer and processes to follow for the appropriate situation. Demarcation Point The demarcation point is defined as a specific location in telephone wire, cable, or other transmitting media on a property owner s premises that separate the facilities furnished and owned by the Company and any other facilities. It is the physical location where the wires and facilities on one side of the point are under the responsibility and control of the Company, and the wires and facilities on the other side of the point are under the responsibility and control of a different party (building owner or customer). Time and material is charged for all work beyond the demarcation point. Point of Service Where the service parameters require terminating equipment such as loopbacks, modems, line-drivers or other active devices, this equipment can be placed at the end of inside wire. Such equipment is not to be considered a demarcation location but as a Point-of-Service. The presence of this equipment is noted on the service order and should be removed when the service is canceled. The time taken to install, option and test the terminating equipment located at the point of service should be charged against the service order if provided as part of a bundled service and is TELUS owned. If the terminating equipment is CPE then extra billing is required (an ELR should be generated to bill the customer for the time to install option and test CPE equipment). Page 3 of

4 4. What does a Demarc look like? a. Copper based services Voice services up to T1 rate special circuits. i. Old style terminal Outside Cable Inside Cable / wire, with fire rated outer jacket Customer owned Tie cable to another building on the same premise Tie cable termination block Jumper wire Inside cable termination block Outside cable Demarcation Figure 4a-i Screw in Electrical surge protectors Page 4 of

5 ii. Newer style terminal for Small business (up to 25 lines) Outside cable Demarcation TELUS side For TELUS approved personnel Customer side Inside wire, with Fire rated outer jacket, connected directly to the customer termination strip Plug in Electrical surge protectors Grounding Outside Copper cable Outside Fibre cable Grounding Conduit to the property line Figure 4a-ii Page 5 of

6 iii. Newer style terminal for larger business (up to 100 lines) Jumper wire Figure 4a-iii Termination of Inside house cable / wire which comes with Fire rated outer jacket. b. Small business Fibre based service 10 meg., DS3, and OC rate (and above) special services Outside fibre Fibre Demarcation Patch Panel for fibre termination TELUS side TELUS approved personnel only Customer side Figure 4b Page 6 of

7 c. Large high rise multi tenant building supplying fibre based services Main Telephone Room MTR Building riser cable & termination panel See Section 5d & figure 5e TELUS fibre cable termination panel Figure 4c TELUS Passive Course Wave Fibre Multiplexer (CWDM) d. TELUS Passive Course Wave Fibre Multiplexer (CWDM) This unit provides E10 & E100 services using 2 fibre strands between the TELUS Central Office and the building termination unit. The in ports of the unit would be patched into the buildings TELUS demarcation patch panel. The out ports of the unit would patch to the customer s riser fibre or electronics within the main Telephone room. Mounting Bracket TELUS Passive Course Wave fiber multiplexer (CWDM) Figure 4d Page 7 of

8 5. What equipment could be beyond the Demarc? a. Copper based Data Service These electronic devices convert the digital signal into a useable format for the customer s end terminal equipment. i. HDSL (High bit-rate Digital Subscriber Line) T1 / DS1 service. (Provides up to 1.5 mbps) These units are use when customer locations are closer to our serving office and within powering range requirement for using this technology. Inside wire (with Fire rated jacket) from MTR to customer equipment is located Jumper wire to feed the HDSL unit HDSL electronic unit Figure 5a-i Page 8 of

9 ii. Smart Interface Jack (SIJ) for conventional powered T1 / DS1 service. (provides up to 1.5mbps) This technology is used when customer are located a greater distance from our serving office and powering of multiple repeaters are required using Pulse Code Modulation (PCM) technology. Figure 5a-ii b. Fibre based direct Optical connection Fibre Connectors - Only the connectors that are spliced on the TELUS side will have optical connectivity to the TELUS network. Fibre patch cords (always yellow) Fibre Patch Panel Opened Customer side Figure 5b Page 9 of

10 c. Fibre based service Media Converter The Media converter is used to convert the OPTICAL signals to ELECTRICAL signals. Below are two different types of converters used within our network. i. Fibre Optic Inter Repeater Link (FOIRL) Inside wire Ethernet copper cable (electrical) FOIRL Converts Optical to electrical Optical Fibre patch cords (always yellow) Figure 5c-i AC / DC electrical power cord (AC plug-in required in Main telephone Room ii. Remote Access Device (RAD) Below is a picture of a RAD device that would be used in the same manner as above. Figure 5c-ii Page 10 of

11 d. Inside Fibre Extension A Splice point is used in the MTR to extend the fibres to a customer s location choice, or when the distance between the MTR and the customer s premise is greater 45 meters and the service cannot be provided on the inside Cat 5 copper wire. The Media Converter would be placed at the end of the inside fibre run. Inside fibre cord splice point Fibre patch cords (always yellow) FOIRL or RAD device will be placed at the end of this patch cord. Inside Fibre patch cords to extend the optical signal to the customers requested Figure 5d DS-3 Optical Services DS-3 optical services would end at the TELUS fibre cable termination panel If the distance to the customer s suite exceeds the maximum distance, a riser fibre cable and equipment can be added (at the customer s expense), to move the optical signal closer to that customer. This is mostly used in high rise applications. Fibre risers and termination panels are use in larger high rise building to extend the fibre closer to the customer. This is not supplied by TELUS. Figure 5e Page 11 of

12 6. How does a customer connect to these devices? a. Copper based service 1. HDSL (High bit-rate Digital Subscriber Line) T1 / DS1 RJ45C Jack for Customer connection Figure 6a-i RJ45C Jack for Customer connection 2. Smart Interface Jack (SIJ) for conventional powered T1 / DS1 RJ45C Jack for Customer connection Figure 6a-ii b. Fibre based service i. FOIRL a. The unit has an Ethernet connection (RJ45 jack) on the face plate for connecting Category 5 (cat 5) inside wire for E10 and E100 services. Page 12 of

13 b. The Ethernet / DS3 unit has a coaxial connection (BNC connector) on the face plate for DS3 orders requiring coaxial inside wire. c. The Ethernet / OC3 unit has an optical connection (SC connector) on the face plate for extending an optical signal on inside fibre. Customer Ethernet connection RJ45 connector Customer coaxial connection location BNC connector Customer coaxial connection location BNC connector Customer optical Connector (SC type) Customer Ethernet connection RJ45 connector Figure 6b-i ii. Remote Access Device (RAD) d. The unit has an Ethernet connection (RJ45 jack) on the unit for connecting Category 5 (cat 5) inside wire for E10 and E100 services. e. The unit also has an optical fibre connection (SFP type) for extending the optical signal on inside fibre. f. It cannot be used to provide a DS3 service. Customer Ethernet connection RJ45 connector Figure 6b-ii SFP fibre connector Page 13 of Date Controlled Material Use Current Version ONLY at Web Site: telus.com/bics TELUS Privacy TELUS

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

Select Engineered Systems Field Bulletin: ATA and Evolving Terminology

Select Engineered Systems Field Bulletin: ATA and Evolving Terminology Select Engineered Systems Field Bulletin: ATA and Evolving Terminology December 2013 As the Cable industry (CATV) has evolved from Analog/RF to digital transmission methods, additional services such as

More information

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data

More information

ONT FIGURE 1 SHOWS THE MOST LIKLEY LOCATION FOR AN EXTERNAL ONT AND ASSOCIATED INTRFACES

ONT FIGURE 1 SHOWS THE MOST LIKLEY LOCATION FOR AN EXTERNAL ONT AND ASSOCIATED INTRFACES Connecting to the National Broadband Network One of the greatest challenges facing telecommunications carriers around the world has been what is known as the last mile, the bit of copper cable between

More information

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities 1 TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions within the Top 48 population

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

T1 Networking Made Easy

T1 Networking Made Easy T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD BICS I CABLING INSTALLATION PROGRAM ANSI/TIA/EIA-570 Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD Copyright BICSI, October 1999 -A Revisited 1.1 Purpose standardize

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

INTRODUCTION TO MEDIA CONVERSION

INTRODUCTION TO MEDIA CONVERSION WHITE PAPER INTRODUCTION TO MEDIA CONVERSION Table of Contents Introduction 1 What is a Media Converter? 1 Advantages of Media Conversion Technology 1 Benefits of Fiber Optic Cabling 2 Types of Media Converters

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

ARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services.

ARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services. ARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services. INTRODUCTION Installing the right wiring when building or renovating

More information

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network.

Public Network. 1. Relatively long physical distance 2. Requiring a service provider (carrier) Branch Office. Home. Private Network. Introduction to LAN TDC 363 Week 4 Connecting LAN to WAN Book: Chapter 7 1 Outline Wide Area Network (WAN): definition WAN Topologies Choices of WAN technologies Dial-up ISDN T1 Frame Relay DSL Remote

More information

How to check for Sync at the NID

How to check for Sync at the NID How to check for Sync at the NID In order for your DSL service to work properly, your DSL modem must receive a clear DSL signal from the phone company s central office (CO). When the DSL modem and the

More information

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property. AT&T Business in a Box Quick Start Guide Please ensure that you have set-up the equipment before the date scheduled with your AT&T Order Manager for Test and Turn Up of your service What s in the Box The

More information

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard. WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of

More information

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS Tech Notes from a Telephone Engineer FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS DDS Description: DDS Digital Data Service Long held industry acronym for transporting digital data at rates of: 2.4kbps,

More information

IP DSLAM IDL-2402. Quick Installation Guide

IP DSLAM IDL-2402. Quick Installation Guide IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...

More information

Chapter 4 Connecting to the Internet through an ISP

Chapter 4 Connecting to the Internet through an ISP Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No

More information

Co-location Arrangements for Interconnecting Canadian Carriers

Co-location Arrangements for Interconnecting Canadian Carriers COMPETITOR ACCESS TARI 2nd Revised Page 95 Cancels 1st Revised Page 95 Co-location Arrangements for Interconnecting Canadian Carriers 1. Service Description Co-location is an arrangement whereby Interconnecting

More information

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs) Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs) Greenfield/Brownfield Renovations Table of Contents Future-Proof your Building... 1 MTS Fibre Optics Installation Guidelines... 2 MTS Fibre Optics

More information

Implementing Fast Ethernet

Implementing Fast Ethernet Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast

More information

FRONTIER TELEPHONE COMPANIES TARIFF FCC NO. 6 Original Page 19-1 ACCESS SERVICE INTERCONNECTION BETWEEN COLLOCATED SPACES

FRONTIER TELEPHONE COMPANIES TARIFF FCC NO. 6 Original Page 19-1 ACCESS SERVICE INTERCONNECTION BETWEEN COLLOCATED SPACES Original Page 19-1 1 INTERCONNECTION BETWEEN COLLOCATED SPACES Dedicated Transit Service Unless otherwise specified herein, general regulations contained in other sections of this tariff apply in addition

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

Outside Plant DS3 Deployment Connectivity Hardware TROMPETER

Outside Plant DS3 Deployment Connectivity Hardware TROMPETER Outside Plant DS3 Deployment Connectivity Hardware TROMPETER E L E C T R O N I C S, I N C. 3G -WIRELESS PASS THRU JACK MODULE WITH NON-INTRUSIVE SIGNAL MONITORING PORTS One of the problems involved with

More information

Reverse Powering Its Benefits and Constraints Daniel Feldman VP Business Development, Microsemi. Power Matters

Reverse Powering Its Benefits and Constraints Daniel Feldman VP Business Development, Microsemi. Power Matters Reverse Powering Its Benefits and Constraints Daniel Feldman VP Business Development, Microsemi Agenda Why Fiber to the Distribution Point? MDU ONT Reverse Power Fed Benefits of Reverse Power Feeding (RPF)

More information

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3 Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

Open Access Fibre Networks

Open Access Fibre Networks Open Access Fibre Networks Contact: 087 470 0800 www.octotel.co.za hello@octotel.co.za 76 Regent Rd, Sea Point, Cape Town Open Access Fibre for Apartment Buildings Super fast Fibre internet for your residents,

More information

Interceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS

Interceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS Interceptor Optical Network Security System } Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS Copyright 2010 Network Integrity Systems, Inc. All rights reserved. The information

More information

Can Extending Ethernet, GigE, DS1 and DS3 Service Be This Easy? Yes. It can.

Can Extending Ethernet, GigE, DS1 and DS3 Service Be This Easy? Yes. It can. Can Extending Ethernet, GigE, DS1 and DS3 Service Be This Easy? Yes. It can. Enable Ethernet, Gigabit Ethernet, DS3, DS1 Services Each Pulsecom access module is self-contained and functionally optimized

More information

Digital Link Cross Connect (DLx ) System User Manual

Digital Link Cross Connect (DLx ) System User Manual Issue, April 998 Digital Link Cross Connect (DLx ) System User Manual Content Page TRODUCTION... Revision History... Trademark Information... Admonishments... Compliance Statement... Certification... Standards...

More information

System Wiring Design Guide

System Wiring Design Guide System Wiring Design Guide This guide will help demonstrate the various types of wiring solutions available when connecting video surveillance cameras to EZ Watch Pro and Armor Pro Digital Video Recorders.

More information

Network Neutrality Statement

Network Neutrality Statement Network Neutrality Statement CTC continues to comply with all applicable FCC requirements while providing the best possible customer experience for its Internet users. As such, CTC commits to the open

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

Objectives. Lecture 4. How do computers communicate? How do computers communicate? Local asynchronous communication. How do computers communicate?

Objectives. Lecture 4. How do computers communicate? How do computers communicate? Local asynchronous communication. How do computers communicate? Lecture 4 Continuation of transmission basics Chapter 3, pages 75-96 Dave Novak School of Business University of Vermont Objectives Line coding Modulation AM, FM, Phase Shift Multiplexing FDM, TDM, WDM

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3 Data Sheet Optimux-1551 STM-1 or OC-3 terminal multiplexer providing access to SDH and SONET networks Any Traffic over Fiber Multiplexes 21/42/63 E1 or 28/56/84 T1 data channels over a single link, providing

More information

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com

More information

Broadband 101: Installation and Testing

Broadband 101: Installation and Testing Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband

More information

Structured and Point to Point Network Cabling for Industrial Automation

Structured and Point to Point Network Cabling for Industrial Automation Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies

More information

APPENDIX A GENERAL DEFINITIONS & SERVICE FUNCTIONS

APPENDIX A GENERAL DEFINITIONS & SERVICE FUNCTIONS APPENDIX A GENERAL DEFINITIONS & SERVICE FUNCTIONS This Appendix provides the basic definitions and service functions of local communications services under the scope of this contract. The Government requires

More information

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration. DESCRIPTION This work shall consist of furnishing and installing 10/100 Ethernet over Twisted Pair (TWP) Copper Modems in accordance with the contract documents and as directed by the Engineer. MATERIALS

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop-O930 E or T Fiber Optical Mux Features Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35, X.2, RS9/V.36,

More information

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet Where to buy > See the product page > High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber Up to 24 Ethernet ports and up to 192 E1/T1 links over fiber and

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

T-Extender E-Extender

T-Extender E-Extender T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop- E or T Fiber Optical Mux Description Features CPU Version Non-CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps

More information

DDP-3 Engineering Guide

DDP-3 Engineering Guide Issue, May 998 DDP- Engineering Guide Content Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications... Admonishments.... GERAL... A. Overview of the

More information

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop-O930 E or T Fiber Optical Mux Features CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35,

More information

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide 8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

Vertical Phone System Upgrades 2014. Scope of Work

Vertical Phone System Upgrades 2014. Scope of Work Vertical Phone System Upgrades 2014 Scope of Work Project Overview Install new Vertical phone system and phones on site. Complete testing with API helpdesk. Remove old phone system, phones and box up for

More information

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches ComNet Fiber Optic and Ethernet Transmission Equipment is setting the standard for value and performance. ComNet is a major provider of video, audio and data transmission, and network communication solutions

More information

Fast Ethernet FX-TX Media Converter. User Manual RINGDALE

Fast Ethernet FX-TX Media Converter. User Manual RINGDALE Fast Ethernet FX-TX Media Converter User Manual RINGDALE Introduction The Fast Ethernet FX-TX Media Converter Provides an ideal solution for extending the cable length of your network, or a way of interconnecting

More information

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section

More information

Getting Broadband. FCC Consumer Facts. What Is Broadband?

Getting Broadband. FCC Consumer Facts. What Is Broadband? Getting Broadband FCC Consumer Facts What Is Broadband? Broadband or high-speed Internet access allows users to access the Internet and Internetrelated services at significantly higher speeds than those

More information

Installing a Physical Network. Chapter 8

Installing a Physical Network. Chapter 8 Installing a Physical Network Chapter 8 Contents Recognize and describe the function of basic components in a structured cabling system Explain the process of installing structured cable Install a network

More information

Gigabit Switching Ethernet Media Converters - Product User Guide

Gigabit Switching Ethernet Media Converters - Product User Guide Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic

More information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1 BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

DXC Family. Multiservice Access Node FEATURES

DXC Family. Multiservice Access Node FEATURES DXC Family Multiservice Access Node FEATURES Digital cross-connection for up to 30 n x 56/64 kbps or T1/E1 over copper or fiber The modular DXC family includes the following chassis types: DXC-30 with

More information

Charter Fiberlink - Nebraska, LLC CHARTER BUSINESS SERVICE PRICE AND TERMS GUIDE

Charter Fiberlink - Nebraska, LLC CHARTER BUSINESS SERVICE PRICE AND TERMS GUIDE Original Title Page Charter Fiberlink - Nebraska, LLC 12405 POWERSCOURT DRIVE ST. LOUIS, MISSOURI 63131 CHARTER BUSINESS SERVICE PRICE AND TERMS GUIDE (This document is not on file with the Nebraska Public

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING TELEPHONE CABLING TECHNOLOGY Main Types Outdoor Voice Grade Telephone Cable Heavy Duty Type, Weatherproof, Sun Protected, Mechanical protection from damage. Some types can be buried in the ground. Cable

More information

FTTH ARCHITECTURE WHITE PAPER SERIES

FTTH ARCHITECTURE WHITE PAPER SERIES Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The

More information

Obsolete Fiber Technology? Not in my Data Center!

Obsolete Fiber Technology? Not in my Data Center! Obsolete Fiber Technology? Not in my Data Center! White Paper October 2011 Author: James Young Technical Director, Asia Pacific www.commscope.com Do you remember when people used to say fiber optics are

More information

TereScope Management Options

TereScope Management Options Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network

More information

24-Port Channelized E1/T1 Line Card Overview

24-Port Channelized E1/T1 Line Card Overview CHAPTER -Port Channelized E/T Line Card Overview This chapter describes the Cisco series -port channelized E/T line card (referred to as the -port channelized E/T line card), and contains the following

More information

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks

Network+ Guide to Networks 6 th Edition. Chapter 7 Wide Area Networks Network+ Guide to Networks 6 th Edition Chapter 7 Wide Area Networks Objectives Identify a variety of uses for WANs Explain different WAN topologies, including their advantages and disadvantages Compare

More information

Fibre Channel Fiber Cabling

Fibre Channel Fiber Cabling OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug

More information

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service 1 Interpretation 1.1 The Direct Fibre Access Service described in this Service Description will be available

More information

Setting Up and Testing the MAX Hardware

Setting Up and Testing the MAX Hardware Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting

More information

Data Center Cabling Design Trends

Data Center Cabling Design Trends Data Center Cabling Design Trends BICSI Regional Meeting Maurice Zetena Fiber Connect Infrastructure Trends Infrastructure Trends Any to All Trunk Cabling Trends: Data Center Infrastructure Media Choice:

More information

Cabling and Building Infrastructure for Technology

Cabling and Building Infrastructure for Technology Cabling and Building Infrastructure for Technology by: Ernest J. Schirmer, Director Information Technology Infrastructure Design CUH2A Architecture Engineering Planning 211 Carnegie Center Princeton, NJ

More information

DEPARTMENTAL REGULATION

DEPARTMENTAL REGULATION U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies

More information

Lumos Networks of West Virginia Inc. d/b/a Lumos Networks Telephone - PA PUC Tariff No. 1 Section 2 Original Page No. 1

Lumos Networks of West Virginia Inc. d/b/a Lumos Networks Telephone - PA PUC Tariff No. 1 Section 2 Original Page No. 1 Original Page No. 1 AGENCY SECTION 2 EXPLANATION OF TERMS For 911 or E911 service, the government agency(s) designated as having responsibility for the control and staffing of the emergency report center.

More information

Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial

Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial Telecommunications Infrastructure Standard for Data Centers 802.3 Tutorial Prepared by: Jonathan Jew - J&M Consultants and Chris DiMinico - MC Communications - Co-chairs TR42.1.1 TR42: Data Center Standard

More information

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Copyright 2007, American Fibertek, Inc. 0411JD Table of Contents Functional Description...3

More information

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for: Broadband Groomer F-330 Series Falco is the industry first Access Unit designed to offer access to SDH/SONET/PDH backbones by different. extends the usefulness of WAN/LAN to and GbE backbones. Falco combines

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

Increase your network s security by making the right premise cabling decisions

Increase your network s security by making the right premise cabling decisions Increase your network s security by making the right premise cabling decisions André Mouton, Product Line Manager Benoit Chevarie, Product Line Manager August 2006 Revision 2 Increase your network s security

More information

Telecommunications systems (Part 2)

Telecommunications systems (Part 2) School of Business Eastern Illinois University Telecommunications systems (Part 2) Abdou Illia, Spring 2007 (Week 12, Thursday 3/29/2007) T-1 Digital Subscriber Line (DSL) Cellular Telephone System Integrated

More information

Loop-IP6700 TDMoEthernet

Loop-IP6700 TDMoEthernet Loop- Description Loop- is designed to transport /T1/DTE/E3/DS3 signal with timing plus Ethernet traffic over IP network, electrical or optical. This is a cost effective way of migrating to IP network

More information

c o m m u n i c a t i o n n e t w o r k s

c o m m u n i c a t i o n n e t w o r k s c o m m u n i c a t i o n n e t w o r k s Founded in 2007, by George Lichtblau Former founder and owner of IFS. Majority of ComNet employees came from IFS. Massive industry experience. Same faces. New

More information

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual Raisecom Technologies July, 2006 Content 1. Cautions... 1 2. Overview... 2 3. Ordering information... 3 4. Parameters... 4 5. Mechanical

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note Plug & Play Gigabit Ethernet Media Conversion Module Application Note The Plug & Play Universal Systems Media Converter Module offers the best of both worlds easy fiber optic scalability and future proofing

More information

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1 Data Sheet Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1 Copper or Fiber Optic Interface, Single/Dual E1/T1 Main Link Modules Connecting Megaplex-2100/2104 to various E1 and T1 services One or two

More information

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below: FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below: Title: Broadband Telecommunications Handbook Author: Regis J Bud Bates Publisher:

More information

Appendix A - Cost Estimate Spreadsheet

Appendix A - Cost Estimate Spreadsheet CCTV Camera, PTZ Per Each $18,500 $1,250 12 $33,500 Closed circuit television (CCTV) camera with pan, tilt, zoom (PTZ) functionality in a dome enclosure. CCTV Camera, Fixed Per Each $14,000 $1,250 12 $29,000

More information

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG High density Fiber Optic connections in the Data Center Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG How to make fast connections. Phill Ward Bicsi National 2 Conference India Projected

More information

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Chapter 9A. Network Definition. The Uses of a Network. Network Basics Chapter 9A Network Basics 1 Network Definition Set of technologies that connects computers Allows communication and collaboration between users 2 The Uses of a Network Simultaneous access to data Data

More information

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6)

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6) SECTION 16750 TELECOMMUNICATIONS SYSTEM (Cat 6) PART 1 - GENERAL 1.01 REQUIREMENTS A. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements, apply

More information