SenseLink TM. End-Point Controller. Addendum
|
|
|
- Phoebe Day
- 9 years ago
- Views:
Transcription
1 SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA Main: Fax: SenseLink Version / P004 Manual Revision A 10/04
2 Copyright This manual and the software described in it are copyrighted with all rights reserved. Under the copyright laws, this manual and software may not be copied, in whole or part, without the prior written consent of MKS Instruments. The same proprietary and copyright notices must be affixed to any permitted copies as were affixed to the original. This exception does not allow copies to be made for others whether or not sold, but all of the materials purchased may be sold, given, or loaned to another person. Under the law, copying includes translating into another language or format. MKS Instruments - CIT Products Group, Scott Blvd Bldg 4 Santa Clara, CA Preface About this addendum This addendum is designed to serve as a guideline to the installation, set up, operation and basic maintenance of the Remote Monitoring Unit with the SenseLink TM End-Point Control Interface features. The information contained within this manual, including product specifications, is subject to change without notice. Please observe all safety precautions and use appropriate procedures when handling the SenseLink TM RMU product and its related software. 2 of 2
3 Table of Contents 1 OVERVIEW AND INSTALLATION WIRING DIAGRAM QUICK-START FOR END-POINT CONTROL SENSELINK TM END-POINT OPERATION STATE MACHINE FUNCTIONALITY SENSELINK TM END-POINT CONFIGURATION CONTROL STATE MACHINE MONITOR STATE MACHINE CONTROL PROCESS PARAMETERS Process Sense Inputs Virtual Inputs Alarms DATA EXPORT TOOL CONTROLLER COMMUNICATION SERIAL COMMUNICATION PARAMETERS MESSAGE STRUCTURE MESSAGE FORMAT Reset Command Ready Command Ready Response Rezero Command Start Command End-Point Event End of Over Etch Event Manual Timed End-Point Event EPDI Error SYSTEM MAINTENANCE IMPORT / EXPORT A CONFIGURATION SET TIME NOTES of 3
4 1 Overview and Installation The Remote Monitoring Unit (RMU) with the SenseLink TM End-Point Control Interface is a data collection, monitoring and control device for managing End-Point of an MKS Process Sense sensor. The RMU provides self-contained logic control, communication and storage of End-Point sensor data. All configuration of the RMU can be done via the web based user interface. After the initial setup, these units collect, store and analyze your data. End-Point calls are communicated via a serial communication interface to the Tool Module Controller. The data is viewed and/or downloaded through a standard web browser. Serial - Endpoint 1 Status Process Sense AO1x - Sensor AO20x - Sensor 20x DO - Fault DI - Rezero Ethernet - Browser / Data Tool Interface +24V, 1.5A +/-15V, 100mA P/S 4 of 4
5 1.1 Wiring Diagram The following connections are required to run this End-Point system with RMU and Process Sense. Connection Points Cable Process Sense RMU Power Supply Ref Signal Signal Pin Signal Pin Signal 1 SENSOR 1X SIGNAL 1X 1 AI1+ IO1 2 SENSOR 20X SIGNAL 20X 2 AI2+ IO3 3 REZERO CAL RETURN 4 DO01 IO VDC -15VDC SUPPLY 6-15VDC 5 +15VDC +15VDC SUPPLY 7 +15VDC 6 +24VDC 24 VDC SUPPLY 8 +, 24V PW1 24VDC 7 SENSOR COM SIGNAL REF 9 AI1- / AI2- IO2,IO4 8 FAULT FAULT 10 DIN1+ IO VDC COM 15 VDC COMMON 13 15VDCCOM 10 24VDC COM 24 VDC COMMON 15 -, DO01C PW3, IO21 24VCOM 11 AI3 JUMPER AI3+, AI3- IO5, IO6 12 AI4 JUMPER AI4+, AI4- IO7, IO8 13 SHIELD HOOD Connectors Ref Connector Description Part Number Manufacturer Qty 1 Process Sense D-sub 15 Female 1 2 RMU PW Pluggable, clamp terminal, 3 pole Weidmuller 1 3 RMU - IO Pluggable, clamp terminal, 28 pole Weidmuller 1 4 Power Supply ferrule 5 5 of 5
6 RMU I/O Wiring The RMU has a 28-pin I/O Terminal Block. Each I/O configuration has unique pin assignments, which are shown in the following tables. The incoming power from the Power Terminal Block is available as a reference voltage on the I/O Terminal Block. I/O Terminal Block for (4) AI Differential, (4) DI - Active Low PIN LABEL DESCRIPTION PIN LABEL DESCRIPTION 28 O4 Digital Output 4 (relay contact N.O.) 27 04C Digital Output 4 (relay common) 26 O3 Digital Output 3 (relay contact N.O.) 25 O3C Digital Output 3 (relay common) 24 O2 Digital Output 2 (relay contact N.O.) 23 O2C Digital Output 2 (relay common) 22 O1 Digital Output 1 (relay contact N.O.) 21 O1C Digital Output 1 (relay common) 20 I4(-) +24VDC common 19 I4(+) Digital Input 4 (sinking, active low) 18 I3(-) +24VDC common 17 I3(+) Digital Input 3 (sinking, active low) 16 I2(-) +24VDC common 15 I2(+) Digital Input 2 (sinking, active low) 14 I1(-) +24VDC common 13 I1(+) Digital Input 1 (sinking, active low) 12 COM +24VDC common 11 24V +24VDC 10 COM +24VDC common 9 24V +24VDC 8 AI4(-) Analog Input 4 (negative input) 7 AI4(+) Analog Input 4 (positive input) 6 AI3(-) Analog Input 3 (negative input) 5 AI3(+) Analog Input 3 (positive input) 4 AI2(-) Analog Input 2 (negative input) 3 AI2(+) Analog Input 2 (positive input) 2 AI1(-) Analog Input 1 (negative input) 1 AI1(+) Analog Input 1 (positive input) 6 of 6
7 2 Quick-Start for End-Point Control 1. Power up RMU by attaching power connector with 24VDC source, 500mA. 2. Attach network crossover cable to RMU and your PC. 3. Modify your network TCP/IP settings to match the following: PC IP Address: PC Netmask: Start up a web browser and point it to You will see the main SenseLinkTM configuration page, showing all analog and digital inputs. There is slight delay as the unit transfers items to your local browser. 7 of 7
8 5. Click on the Control tab, to see the main settings for End-Point. 6. Click on State Machine Monitor, to see the running state of the End-Point logic. As you run a Clean, the state machine will cycle through each step, highlight in green, and show an elapsed time indicator bar. Last serial command received from controller is displayed on bottom toolbar. If you are not connected to the Tool, you can simulate these commands by using the State Machine Control panel. 8 of 8
9 7. Click on the Alarms tab to see the End-Point logic definitions. These can easily be changed by clicking on Edit. 8. Click on Traces tab to see the data collection plans. Go to the second data collection plan, labeled Monitor. Click on Open under the Chart icon 9 of 9
10 9. Next you should see the Trace Monitor Open revealing real time data. 10. To manipulate the chart, there are several useful icons. The most common are: Show names (provides the labels of each I/O) Crosshair cursor (crosshair with exact value and time) Show all (shows all data in the current collection, compresses time scale) Tuning Trajectory Graph Logarithmic Scale Toggle Events Round Full Scale Crosshair cursor Digital Readouts Advanced Options Offset Transparent Show all Use Scale of selected series Show names 10 of 10
11 11. Transport the collected data to your PC. After a Clean, data will be stored. Under the Traces tab, for the CleanData plan, in the Download Data column, select Download. A page will open to provide options on the timeframe of data you would like to access. 12. Click on Download and the data will be sent to your PC, for MS-Excel viewing. 11 of 11
12 3 SenseLink TM End-Point Operation On power-up, the RMU with SenseLink End-Point Control will automatically begin running its control state machine for end-point detection. The unit is monitoring all specified sensor signals and waiting for serial commands from the Tool Module Controller to begin detection. There are 4 processes running in the SenseLink environment, in a multi-tasked method: 1. End-Point control process state machine 2. Data acquisition 3. Data logging 4. Alarm logic Processes #2 - #4 are part of the standard SenseLink architecture, and are described in the SenseLink Users Manual. Process #1 is defined in this addendum, as this task is application specific. 3.1 State Machine Functionality The Process State Machine runs in parallel with the data acquisition, data logging, and alarm monitoring. The following Graph shows a typical process feedback and the interaction with the End-Point logic states: Start Process Process Delay Endpoint Level Endpoint Slope Process Variable Raw Sensor Data Averaged Sensor Data End Etch Time 12 of 12
13 3.2 SenseLink TM End-Point Configuration The end-point configuration uses the standard SenseLink TM application with the addition of an application specific Control tab. The control functionality used in conjunction with a properly configured SenseLink TM application performs End-Point control and tool communication. 3.3 Control The Following Screen shot is for Control Tab settings. It uses the Inputs from several analog, digital, and virtual inputs to create the logic for End-Point control. Film Type Allows the definition of End-Point Recipes or multiple setups that store all of the parameters for End-Point under a Film Type name, and utilize these when the Start command specifies this Film Type. Film Type Overview provides a comparison chart of all Film Type parameters 13 of 13
14 Endpoint Level is an alarm used to transition the state machine into the Monitor Slope State. Endpoint Slope - is an alarm used to transition the state machine into the Over-Etch State. Error Event is an alarm used to determine if a sensor error has occurred. This is a digital input from the Process Sense controller. An Active Low ON signal indicates the Process Sense is OK. Absence of this signal indicates a Fault condition. Collection Plan is used to determine which collection plan will be used in the Control Process. This is the data stored during the End-Point control process. Delay Time The Delay Time is used to delay the start of the Endpoint Monitor state of the state machine. This allows the process to stabilize before the End-Point algorithms are activated. Crossover Time a timeout parameter. Maximum time that can be spent waiting for an Endpoint Level event. If crossover time expires, control moves to the next state, Endpoint Slope. Min Overetch Time is the minimum over-etch time from the detection of Endpoint Slope. Actual overetch time is calculated as a % of total time elapsed from the Start command to beginning of Over-Etch state. The % is passed in the Start command, from the Tool controller. Manual Etch Time is used the set a manually timed Clean, if the state machine is bypassed. Baud Rate is used to set the baud rate for the RS232 port used for tool controller communication. Rezero - is used to set up the re-zero process for the input sensor. It can be set up for a software or a hardware process. Hardware re-zero of a Process Sense requires an Active Low signal for a 3 second duration. Rezero Limits If checked as active, these limits will be used to test the value of the sensor signal after a re-zero is complete. If the sensor signal does not fall within this range, an Error notification is sent to the Tool Controller. End-Point Controller is reset to the Idle state. 14 of 14
15 3.4 State Machine Monitor Provides visual indication of the state of the End-Point Controller Idle Process State Machine is waiting to begin. Actual Process Sense data can be viewed using the Monitor collection plan, but is not stored. ReZero Process State in which the analog sensor is calibrated to a new zero point. Ready Process State Machine has calibrated sensor and is waiting for a Start command from the Tool controller. Delay Process State that uses the Minimum Delay to allow the process to stabilize, before beginning End-Point control algorithms. Monitor Level Process State that monitors Endpoint Level. Monitor Slope - Process State that monitors Endpoint Slope. Overetch Timed state to allow additional Clean time. Actual over-etch time is calculated as a % of total time elapsed from the Start command to beginning of Over-Etch state. The % is passed in the Start command, from the Tool controller. Time Only Process State which can provide a manually timed Clean. Used when all End-Point algorithms are bypassed. 15 of 15
16 3.5 State Machine Control State Machine Control is a simulation aid, to run End-Point process through a direct user interface, rather than Tool Control via the Serial Communication port. This function runs in parallel to the Serial port commands from the Tool controller. To simulate a command, select the action and then click on Send. Details for each command are found in section 4, Tool Controller Communication. 3.6 Process Parameters All of the logic parameters are setup in the data acquisition and alarm sections of the SenseLink environment. Reference the SenseLink Manual for a complete description. The main parameters used for End-Point detection are summarized here Process Sense Inputs AI1X and AI20X are the main sensor inputs coming from the Process Sense. These are located under the Channels tab, and can be scaled here. Default units are Volts. 16 of 16
17 3.6.2 Virtual Inputs Virtual inputs are variables which result from functions. For End-Point control, Average and Derivative are the common functions which are traced and collected Alarms Alarms are the conditions used to create the End-Point logic. By default, one is used for level, the other for slope. The logic, however, is completely open to the User. A complete list of operations is located in the SenseLink Manual. 17 of 17
18 3.7 Data Export Data stored in the RMU is available for export in several formats. Most of these are described in the SenseLink Manual. An additional format is provided exclusively for End-Point Control. The data for each Clean cycle can be selected individually for download. From the Traces tab, go to the Clean Data collection plan, and Click on Download Data. Click on Get List, and All cleans available will be shown. Select those you want for download, and click Select. The Window will close, and you choose which destination (usually CSV - MS Excel), and Click on Download. 18 of 18
19 4 Tool Controller Communication The communication between each Tool controller and the RMU will carried over a dedicated serial communicating line (RS-232 line levels). The RMU will use its COM3 (/dev/ttys1) port (/dev/ttys0) for this purpose. Each connection will use a DB-9 type connector with RX, TX, and GND lines. 4.1 Serial Communication Parameters The following defaults communication parameters will be set at the RMU. Parameter Value Baud Rate 1200 Data Bits 8 Parity None Stop Bits 1 Flow Control None 4.2 Message Structure The message content will comprise of ASCII byte streams of variable length, based upon the message type. The following special characters will have special meaning. Character ASCII Code Description SPACE 0x20 Separates several parameters in a message : 0x3a Indicates a value assigned to a parameter <CR> 0x0d Indicates the end of a message 4.3 Message Format The following table summaries the different messages between the Tool Controller and RMU (EPDI). Message details will be described in details in the following paragraphs. Message From To Description RESET Tool RMU Reset command READY? Tool RMU Ready command READY RMU Tool Ready response REZERO Tool RMU Rezero command 19 of 19
20 Message From To Description START Tool RMU Start monitoring command ENDP <C> RMU Tool End Point Event EPOE RMU Tool End of Over Etch event EPERR RMU Tool EPDI Error message The following describes in details the message format for each request and command. The flowing notation will be used: <D> Indicates a single alphanumeric character (0-9). <DD> Indicates two alphanumeric characters (example: 123) <FF.FF> Indicates a floating point number (for example 3.62, -0.45) <SSSSSS> Indicates a variable length character string. <C> Indicates one Character <CR> Indicates end of message (carriage return) Reset Command Purpose Message Format Response Example Force the EPDI into the IDLE state RESET<CR> None RESET<CR> Ready Command Purpose Message Format Response Example Check for presence of the EPDI system; prepare the EPDI (perform re-zero operation from an Idle State). READY?<CR> Ready Response if re-zero was finished OK, Error Response if sensor s fault bit was set during operation. READY?<CR> 20 of 20
21 4.3.3 Ready Response Purpose Message Format Response Example EPDI response to Ready Command (when no error detected) READY<CR> None READY<CR> Rezero Command Purpose Message Format Response Example IF in Ready or Idle State, triggers a Re-zero function. The method of Re-zero is defined by the parameters from the Control tab, and will be either a s/w or h/w rezero. If Re-zero Limits are enabled, these will be checked at the end of the Rezero function. REZERO<CR> Error Response if limit test failed or Sensors fault bit was set. REZERO<CR> Start Command Purpose Message Format Response Example This command sends all required configuration parameters to the EPDI and instructs it to start monitoring. The message will provide the EPDI with the following 6 configuration data (all of them are mandatory): N: Parameter count. Always 6 ftyp : Film type (string) dpos : Film thickness (angstroms, integer) echt : Estimated Etch time (seconds, integer). ovet : Over-Etch time (% of echt, integer). batch : Batch size (integer). mode or EPD : Endpoint mode (0 = timed, 1 = Use EPD algorithm) START N param1:data1 param2:data2 paramn:datan<cr> None START 6 ftyp:xxx dpos:100 echt:40 ovet:7 batch:10 EPD:1<CR> The following describes the possible values to the mode/epd parameter: Algorithm Type Value Description Timed 0 Use the time value in the configuration d b d i d i N 21 of 21
22 database to determine end-point. No Over Etch will be calculated Algorithm 1 Perform detection according to more (Level, Slope, Conditional). Also, performs Over Etch detection per ovet parameter End-Point Event Purpose Message Format Response Example EPDI has detected the End Point event. Several types of Endpoint events can be reported: - ENDP L: Level Endpoint event (for Level and first step of Conditional detection) - ENDP S: Slope Endpoint event (for Slope and second step of Conditional detection) - ENDP F: For Conditional detection, when Crossover Timer expires before a Level Endpoint event detected. ENDP <C><CR> None ENDP L<CR> End of Over Etch Event Purpose Message Format Response Example EPDI has detected that the over-etch time has expired EPOE<CR> None EPOE<CR> Manual Timed End-Point Event Purpose Message Format Response Example EPDI is running in Manual Timed mode. Time has expired. ENDP<CR> None ENDP<CR> 22 of 21
23 4.3.9 EPDI Error Purpose Message Format Response Example EPDI has detected errors during its operation (in any of its states, per the state diagram) EPERR<CR> None EPERR<CR> 23 of 23
24 5 System Maintenance 5.1 Import / Export a Configuration Once an End-Point configuration is complete, save the configuration by clicking on the Export Config function. This will allow you to name a file and save it on your local machine. To duplicate this configuration on another RMU, simply import this same file using the System Update function. 5.2 Set Time Change the base time using the Set Date and Time function under the Maintenance tab (above). There is also the capability to synchronize to a network based time server. This function resides under the Network tab. 24 of 24
25 6 Notes 25 of 25
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos
Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos HMS Industrial Networks AB Page 1 (37) History Revision Date Description Responsible 1.11 2012-09-26 Typos SDA
Modbus RTU (RS-485) TCP/IP (Ethernet)
Eaton Innovative Technology PEM PC Software Installation and Operation Instruction Manual: IM01005006E Rev. 2 March 2007 Modbus RTU (RS-485) TCP/IP (Ethernet) Effective Date 3/2007 For more information
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
TruePort Windows 2000/Server 2003/XP User Guide Chapter
TruePort Windows 2000/Server 2003/XP User Guide Chapter 0 This document provides the procedure for installing and using TruePort on Windows 2000/Server 2003/XP. Table of Contents What is TruePort?...3
Part Number 129777-01 Revision A, January 1996. 3500 Monitoring System Rack Configuration and Utilities Guide
Part Number 129777-01 Revision A, January 1996 3500 Monitoring System Rack Configuration and Utilities Guide Copyright 1995 Bently Nevada Corporation All Rights Reserved. No part of this publication may
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Innovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos
Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos (Remote monitoring of data in the Millenium 3 using SL-In/SL-Out function blocks) Your partner for industrial
32 Transferring Projects and Data
32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
MS830 / MS833 Barcode Reader v1.0 9-December-2014
MS830 / MS833 Barcode Reader v1.0 9-December-2014 Publication Information 2014 Imagine Communications Corp. Proprietary and Confidential. Imagine Communications considers this document and its contents
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
Work with Arduino Hardware
1 Work with Arduino Hardware Install Support for Arduino Hardware on page 1-2 Open Block Libraries for Arduino Hardware on page 1-9 Run Model on Arduino Hardware on page 1-12 Tune and Monitor Models Running
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet
Ovation Operator Workstation for Microsoft Windows Operating System Features Delivers full multi-tasking operation Accesses up to 200,000 dynamic points Secure standard operating desktop environment Intuitive
PPM Users Manual Signature Software 01-12-00
PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower
CONCEPT1 RS232 COMMUNICATION
Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection
Getting Started with IntelleView POS Administrator Software
Getting Started with IntelleView POS Administrator Software Administrator s Guide for Software Version 1.2 About this Guide This administrator s guide explains how to start using your IntelleView POS (IntelleView)
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
CRE Monitor Instructions Manual
CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
Serial Communications
April 2014 7 Serial Communications Objectives - To be familiar with the USART (RS-232) protocol. - To be able to transfer data from PIC-PC, PC-PIC and PIC-PIC. - To test serial communications with virtual
Operating Instruction MEW01652 Revision -
Operating Instruction MEW01652 Revision - OPC512 G3 V2.0.x for Web-server II, 1598 Author: Rutger Pålsson Date of issue: 2013-05-21 Date of rev: This page has deliberately been left blank. Table of contents
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version
USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
Using HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
DVR-4TL/8TL/16TL Setup Guide
Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration
LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration VERSION 1.00.00 USER MANUAL Updated 09/13/2002 Table of Contents Hardware/Software Requirements...2 Computer Requirements...2 Instrument
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
Introduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL
WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : [email protected]
Config software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F
Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature
UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction
User manual Central Unit for Alarm System (CUAS) Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end
Getting Started Guide with WIZ550web
1/21 WIZ550web is an embedded Web server module based on WIZnet s W5500 hardwired TCP/IP chip, Users can control & monitor the 16-configurable digital I/O and 4-ADC inputs on module via web pages. WIZ550web
Signature Center Getting Started Guide
Signature Center Getting Started Guide 1113710 PRODUCED IN IRELAND Copyright 2010 McKesson Corporation and/or one of its subsidiaries. All Rights Reserved. This documentation is an unpublished work of
for Windows Media Center User's Guide
for Windows Media Center User's Guide Table of Contents Introduction System Requirements Installation Running HAI Home Control Using HAI Home Control Product Support Introduction Thank you for purchasing
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
How to Program a Commander or Scout to Connect to Pilot Software
How to Program a Commander or Scout to Connect to Pilot Software Commander and Scout are monitoring and control products that can transfer physical environmental conditions and alarm sensor electrical
SYMETRIX SOLUTIONS: TECH TIP August 2015
String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different
Float Current Monitor FS3. User Manual
Float Current Monitor FS3 User Manual Version 4.2.1 Copyright Polytronics Engineering Ltd. 2009-2013 All Rights Reserved Table of Contents 2.1 Installing the Core... 9 2.1.1 Installing as Ground Fault
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
Vicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0
3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)
with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021) Alex Chen, Senior Engineer, Moxa Technical Support Dept. In this Technical Note, we cover the following topics: 1. How to export
Condition Based Monitoring Dashboard User Manual. User Manual
Condition Based Monitoring Dashboard User Manual User Manual USA Advantech B+B SmartWorx 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.advantech-bb.com
Using IDENT M System T with Modbus/TCP
Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC-10000. http://wattsview.com. WattsVIEWTM. Models: DC-10000 Serial DC-1000 USB DC-25000
WattsVIEW Power Monitor Model: DC-10000 DC Power Monitoring Made Easy Models: DC-10000 Serial DC-1000 USB DC-25000 OWNERS MANUAL PAGE 1 of 23 Table of Contents WattsVIEW Power Monitor Model: DC-10000...1
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
DAQlink III System 24 bit Acquisition System
DAQlink III System 24 bit Acquisition System User s Manual DAQlink III System User s Manual Printed in U.S.A. 2008 Seismic Source Co. All rights reserved. This document may not be reproduced in any form
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control