#3 LV network monitoring in the Demo2

Size: px
Start display at page:

Download "#3 LV network monitoring in the Demo2"

Transcription

1 #3 LV network monitoring in the Demo2 Type of solution Equipment / Hardware / Firmware Information system Manufacturer(s) implied (for equipment or hardware) ABB emeter Siemens Schneider Electric LV Innovation Work Stream considered Location / Topology (with regards to distribution grid) MV/LV SS Meter Other Centralized system (calculations, information system) Thematic(s) Grid Monitoring / state estimation Use Case(s) Outage detection in the LV Network Key figures Demo2: ~ Smart Meters connected to the demo site area >100 secondary substations equipped with RTU supervision Secondary Substation sizes range between 2 and 17 outgoing feeders >600 outgoing LV feeders monitored Table- 6 Technical table of the LV network monitoring in the Demo2 Objective and technical requirements The objective for the project is to demonstrate a solution for improved outage and power quality management of the Low Voltage network. The solution is based on the already existing Smart Meters, which Vattenfall deployed at all customers several years ago. The deployment of Smart Meters could be seen as the first step of a Smart Grid solution. Introducing RTUs to the solution will be the second step of a Smart Grid solution, which we believe will support further business development in order to reach for the smart energy enabler platform. This technology will support the development towards more micro-scale production, smart homes electric vehicles, reduced CO2 emissions etc. Figure 3 - Demo2 principal technical solution for LV network monitoring The technical platform will have the possibility to provide better results compared to what data from a single component and system may provide. Both the RTUs and Smart Meters will add insight to the LV network current status and submit information in real time for operational management decisions in order to improve the quality of supply to the customers. The technical solution has the potential to be used in multiple ways and support different purposes. The monitoring platform will serve as a dynamic tool for fast and reliable power quality analysis as well as improved service to the customers. Requirements The orange areas on the map show where Vattenfall operate MV and LV network. About 83% of the secondary substations and approx. 57% of the customers are classified as part of the LV rural network. This is the reason why the number of customers on average per secondary substation for the Vattenfall LV rural network is relatively low, 14,4, compared to the average of 21,7 customers per secondary substation including both urban and semi-urban areas. 7 Context & Objective Demo2 is participating in GRID4EU with the main purpose to demonstrate a possible solution for LV network monitoring, by deploying intelligent equipment in secondary substations (RTUs) and use the Smart Meters at customer premises. Information from two different sources in the same LV network circuit, will be used and combined in an integrated back office system environment. The benefit of the solution is believed to support different user needs and operating functions such as network planning, optimization, power quality analysis, field service processes etc. Figure 4 - Vattenfall MV and LV network areas in Sweden

2 These pre-requisites are important to understand when designing a cost efficient technical solution for LV network monitoring, with the purpose to improve outage and power quality management. The network topology has impact on the result for the chosen Demo2 technical solution for monitoring of the 400 V line in the secondary substations. Typical Vattenfall rural network In general, rural LV network is characterized by: Overhead lines common, with a mix of isolated and noninsulated wires. However in certain regions underground cables are becoming increasingly common as well 1-1,5 km between secondary substation and customer Mainly small pole mounted secondary substations, with smaller transformer ratings Majority of customers connected to the SS without fuses in cabinet to end user line, although this practice is no longer common for new connections HV fuse Transformer kVA (400 V) L4 L3 L2 The system environment, the location to host the system hardware, was selected based on primarily IT and Information security regulations. The hardware is located outside Vattenfall ordinary network, on a test net operated by Vattenfall R&D department. Open network connections between the Vattenfall corporate network and the Demo2 environment was not allowed to be established. Data was also needed to be anonymous. Architecture and technical characteristics The technical solution comprises of 3 parts: RTUs connected to each outgoing LV line, all three phases are measured. RTU s are communicating with built in GPRS modem, using IEC protocol. Smart Meters at customer premises. Smart Meters are using PLC communication with the Data Concentrator in the secondary substation. DCs are communicating with built in GPRS modem, using OSGP protocol. Overlying system applications. ABB Micro SCADA Pro and DMS is collecting the RTU data and Schneider Electric AMI Platform Head End Titanium system is collecting the Smart Meter data. The AMI system is exporting the Smart Meter data, measurement values and events/alarms to emeter/siemens EnergyIP MDMS system. Pole mounted L1 Group fuse (Overhead line) Line fuse 35A to 63A (Earth cable) Street Cabinet Supply line fuse to all customer premises In normal case (>95%) = 35A (Overhead line) LV fuse, normally 63A-125A Ca meters Figure 5 - Typical Vattenfall (Swedish) rural LV network Given the situation for the LV network operations by Vattenfall, the Demo2 technical solution is designed primarily to identify LV group fuse faults in the secondary substation. This was a conscious choice, with respect to the network topology and the cost for the solution per secondary substation. In general the solution is not designed to detect faults due to loss of load on one phase. Situations with instantly decreasing load on one phase should not be interpreted as an outage. It may happen that a customer behaves in such a way. Those kind of situations would require a specific power quality meter, in order to better judge the situation by the operators. Identification of faults downstream street cabinets, e.g. broken fuse in cable cabinet, broken cables due to digging and trees on line 3, faults only affecting single premises may be supported by the Smart Meters event reporting, even though clear outages (power off) are not possible to detect in real time. As smart meters use PLC as the communication media with DC, it is not possible to use that media when there are power outage situations. However, the operator in the Control Center would be informed in near real-time that the communication was lost with smart meters (through Meter Down events). Then, if the operator started receiving Meter Down events for all the meters downstream a street cabinet, it would be very useful for identifying an LV fault in that street cabinet. Development and implementation The design of the RTU solution was made by ABB with input from Vattenfall on requirements and installation pre-requisites. All sites were visited and documented prior the deployment of the RTU cabinets. 3. Most 400 V lines are today changed from copper or iron core to Alu. The new lines are stronger and will not snap if a tree falls on a line. Figure 6 - Demo2 metering equipment in the LV network Lab tests ABB functionalities The use of a RTU solution in secondary substations allows the detection of outages and LV faults. The RTU detects an outage or a LV fault, e.g. a drop in current on one or more phase, and reports a warning to the SCADA system. This improves the fault awareness time. The SCADA generates an alarm, which is instantly processed by the DMS to red mark the line in questions to indicate the loss of power. This improves the fault location time. The isolation work is done manually by the operator who uses information mainly from the RTU to work more efficiently. This information will help to reduce the isolation time in field. DMS Within the Distribution management system (DMS600) ABB has implemented two functionalities. Both target operator awareness and in aim to shorten lead time in fault location and fault resolution times (SAIDI); AMR Meter Event visualization - A functionality which processes selected high priority events from the meters at customer premises and maps them to the right meter in the DMS. The DMS has a complete representation of all customer meters on the feeders monitored within the demo. This 8 8

3 functionality allows an operator to quickly spot where a specific customer event is located. In figure 7 below, each Number is a meter and the meter has been marked red due to a Device tampering event. The substation that the meter is connected to (XSS000109) is also marked red for ease of tracking. Figure 7 - ABB DMS Visualization of events from customer meters - In the report pictured below three lines are shown. Green shows consumption data based on aggregated data from customer meters. Orange shows supplied energy as measured in the secondary substation. Red shows the difference, which is unbilled energy. This report can help detect power theft. (Please note that the feeder producing data for the graph has been chosen for its irregular consumption pattern, to illustrate the functionality of the report). Graphs for power quality monitoring and analysis - The multimeters in the field provides a range of data for each phase per outgoing line. The values cover active power, reactive power, power factor, frequency, accumulated energy and harmonics. Out of these values the operators choose which data to view and to what granularity. - Historian supports resolution down to millisecond level and allows for combination of values within the same graph. To visualize this, the picture in figure 9 shows the total harmonic distortion as a percentage deviation from pure 50Hz. 9 Current or voltage drop visualization - As a way to signal a drop in current on a feeder or voltage drop in the busbar in the LV network. ABB has implemented a functionality that mimics the behaviour of the DMS in case of a breaker opening. When the SCADA gets a signal that a line drops to near zero current, the fictive breaker is set as open and the line in question is marked red to indicate the loss of power. The combination of these two functions gives an operator swift indication when a fault occurs. This enables quick action to be taken, either to monitor that power is restored or to initiate an investigation. SYS600 Historian The SYS600 Historian is a historical database. It is dynamically updated and presents live data along with historical data to give graphs of measured values. The operators choose content. Through discussions with Vattenfall operations staff ABB has created graphs that helps operator monitor, live or historically, the consumption, power quality and technical losses. Technical losses - The historian has access to data on energy supplied on each outgoing feeder in any substation. At the same time the system receives meter data on consumed energy from the individual meters connected to the feeders. Historian then produces a graph where supplied energy, consumed energy and the diff on a selected feeder or substation is shown. By setting this up per station, it is easy to identify troublesome stations and on those set up monitoring for the individual feeders to further pinpoint the source of the technical loss. Figure 8 - Graph of energy and losses. Red is the difference between energy supplied (orange) and energy billed (green) Figure 9 - THD as percentage deviation from pure 50 Hz All values stored in Historians database can be exported to spreadsheet format. The selection of data can be done from the graphical interface where the operator marks the timespan to be exported. This means that the historical database can be used both for at a glance monitoring and for analysis to provide input for proactive maintenance. emeter Functionalities EnergyIP MDMS platform provides a tool for in-depth analysis of customer and network behaviour. The high level functional configurations and integrations relevant to EnergyIP MDMS testing in order to run MDMS properly are: VPN environment The demonstration application is installed as a stand alone solution, separated from the operating Vattenfall system environment. Asset Synchronization Network assets and relationships was made in a one-time synch with Vattenfall Master systems and EnergyIP. The same with ABB DMS/RTU system data. Meter Read and Event processing Interfacing with the AMI system (measurement values and events/alarms) is done via VIP (Vattenfall Integration Platform). Data from the DMS_RTU is processed using a file format point to point connection. The reporting framework Analytics Foundation is designed to pull data out of EnergyIP s MDMS and create a purpose built database. From the wide range of reports, only Load Analysis and Device Event reports were used for Demo2 analysis. Data from MDMS db to Analytics Foundation db using ETL (Export/Transform/Load) Aggregation of data and report configuration

4 Field implementation ABB and Vattenfall field implementation ABB has created a series of metering cabinets for the GRID4EU. Uniformity and common components has been the key focus in the design process. All cabinets use the same RTU, multimeters, antennas and power supply. To cover all 100+ installations only four different cabinet sizes have been used. The adaptation of the cabinets is done by varying the number of multimeters, one per each outgoing group. Figure 12 - In bigger stations the solution can be taken out of the housings and be mounted on any available space in that substation Figure 10 - Snippet from a layout showing two of the larger cabinets and their suggested number of multimeters This approach allows for fast and efficient design and construction. That is a central factor in cost efficiency in the perspective of a bigger roll-out where the number of stations is significantly higher. It does however require the DSO to have good knowledge of the stations where the cabinets are to be installed. In many cases an inventory of the stations is needed in order to assert that the right number of multimeters are installed and that there is room to mount the equipment. The largest cabinet (LARGE) in the Demo2 is 600x800x200 mm (BxHxW) and houses up to 16 multimeters. The smallest cabinet (MICRO) is 300x600x200 and houses 1-3 multimeters. All cabinets contain power supply, heating and communication equipment (GPRS modem in the RTU). System implementation System implementation was made in the Vattenfall R&D location Älvkarleby and is connected to a test net, entirely separated from the ordinary Vattenfall corporate network. In order for the Demo2 environment to operate as intended it is depending on information from outside connections. There are three different kind of connections between TestNet and external sources; client VPN, system VPN and SFTP. Client VPN (orange lines) is used primarily to administrate the systems by the Demo2 partners. System VPN (green lines) is used by the communication service provider Sierra Wireless for RTU data collection. SFTP (blue lines) is used for transferring Smart Meter data from Vattenfall to Demo2 system environment. Figure 13 - Demo2 system set-up as a stand-alone solution Technical results Figure 11 - The smallest cabinet in the Demo2 family, model designation MICRO They are prepared to be mounted on poles or walls. All cables run through the back plate in order to minimize exposed parts. All equipment is DIN-rail mounted on a separate back plate. This allows installation to be done without the cabinet at indoor stations where the available space is an issue. ABB Technical results The results are divided between the performance of field equipment and the technical innovation of the DMS600 and Historian functionalities developed. RTU performance When RTU s are used for network monitoring, like they are in Demo2, the reliability of their communication becomes a key factor. One of the central KPI s of the projects measures the population of RTU s on just this. Out of 108 RTU the following performance results have been determined. Average RTU availability after field visits, fine tuning of RTU configuration and upgrade of firmware was recorded to approximately 95%. An increase in the availability from peak low 50% on average before improvement actions were undertaken. 10

5 The communication process has tested both GPRS/2G and 3G technology. Comparing the GPRS/2G with the 3G technology result in an advantage for the 3G technology when being used in a Smart Grid context. The 3G technology especially supports the RTU <-> SCADA process in the need for maintenance work, real-time monitoring and higher data traffic volumes. In order to reduce the data traffic volume between the RTU and the SCADA system, the RTUs are activated with deadband. The RTU is collecting and storing data, individual values, up to the defined limit for the deadband threshold, which is a change in the RMS value for more than 50 percent compared to the previous value. The RMS value can be changed by more than 50 percent immediately from one value to another and in this case the RTU will send the data to the SCADA system. Alternatively, the RTU will collect and store the change in RMS values until the accumulated sum of those changes is greater than 50 percent from the previous value. This will then trigger a sending of data to the SCADA. The longest interval between two data packages sent from the RTU to the SCADA system should not be more than 60 seconds. This configuration of the RTU will not impact the functionality of the solution. Large deviations in the values will be immediately reported as warnings and normal operation will be reported with less frequency Typical data usage per RTU depends on the size of the secondary substation and the power quality on the LV network. For the project period the volume range between approximately kb per day. AMR events The AMR events function uses a Graphical User Interface (GUI) within the DMS600. It sorts incoming events by type and reporting substation. Each event contains information on which meter has sent it, time stamp when it was sent from the MDMS system, type of event and which secondary substation that signaling meter is connected to. The info about the substation is given as extra information to help reduce the time needed for fault restoration. The operator chooses to locate or reset the alarm using buttons in the GUI. If the locate function is enabled, the map system of the DMS zooms to the LV network where the meter is located and high lights the specific meter. This function makes it possible for an operator to easily monitor large LV grids for specific event types or trends. The system uses the IEC interface to send real time events and alarms to the DMS. on feeder, station or LV grid level. For an example of graph, see figure 15 above. Figure 15 - Available data from RTUs The main part of the data available comes from the RTU s and is listed in figure 15. It should also be noted that the database provides functionality to import data from other devices in the Demo2 system such as meter data using CSV files. emeter Technical results Especially Load Analysis and Device Event reports will be studied for the Demo2 demonstration. Load Analysis Load analysis reports show load usage data, load curves, and load duration curves. These reports provide a way to drill into load usage, from a high-level overview showing load usage and load duration. The Load Curve for a Substation, illustrated below, is an example of the comparison of substation load compared to the nameplate and derived rating of the low voltage substation transformer. This can be useful to study season, or daily peaks or the impact of load switching. The loading below shows a trending loading decrease from the beginning of April. Figure 16 - Demo2 Load curve for a substation presented in EnergyIP 11 Figure 14 - The AMR event GUI. Active alarms are sorted based on event/alarm type and each even contains all information needed for operator analysis. Statistical data and PQ monitoring Within the results for PQ monitoring ABB s Historian suite provides a range of graphs based on any combination of the provided data. Consumption data from meters and secondary substations combined provides technical losses data or graphs Comparing the Load Curve to the DMS_RTU data can provide additional insights to the analysis. The individual meters may be graphed to illustrate the customer that has the highest contribution to the aggregate load of a substation or feeder. In the sample below Feeder- Multiple AMI Meters meter A contributes close to the entire feeder loading. Figure 17 - Demo2 Meter contribution to the entire feeder loading presented in EnergyIP

6 Device Events Device Event reports can be used to track outage issues, trends, and impacts. These reports provide a way to drill down into events from a high level substation view to individual customers or single delivery points (SDP). For the demo period events were received from March through August into the Analytics Database for study, refer to Device Events Summary below. Events are sorted into predetermined buckets for easier analysis and focusing on outages June 6 is a spike for the time period. The Device Event Summary Table shows that 192 SDPs experienced an outage at that time. Figure 18 - Demo2 Device event summary table presented in EnergyIP Elements of Cost & Benefits Analysis Even though the RTUs are installed on the outgoing LV lines, the RTUs can also support operation on the Medium Voltage side of the secondary substation. A broken fuse on the MV side (10 kv) can be detected by the RTU due to the fact that the load on the LV side then will become asymmetrical. Therefore the benefit analysis includes also MV side. The JRC (Joint Research Centre) report, Guidelines for conducting a cost benefit analysis of Smart Grid projects, has served GRID4EU with guidelines for calculating Smart Grid Cost Benefit Analysis (CBA). The JRC report is grouping these benefits into four categories Economic, Reliability, Environment and Security. These four JRC categories includes 23 possible benefits for Smart Grid projects. This analysis has focused only on reduced sustained outages defined as: Reduced outage time through early awareness of failure event by DSO. Potential outage time reduction due to shorter restoration time thanks to information that help in localization of outage and better management of maintenance personnel. The benefit was analysed in terms of reduction of SAIDI in minutes by using the deployed RTU solution in rural secondary substations. The work covered to analyse the outage management process with and without the support of RTUs and identified the type of faults as well as the number of registered MV and LV faults in 2014 that would have been possible for this solution to detect. An average on the number of affected customers per MV high voltage and LV low voltage fuse faults was also defined. The final calculation of the impact on SAIDI that this RTU solution may have on reduced sustained outages faults, according to JRC terminology, is estimated to be in the range of 5-12 percent, or approx minutes reduction of SAIDI for both MV and LV network. The analysis showed a result which was not anticipated from the beginning. Initially the scope for the BC was only to analyse what impact measurement in secondary substations could have on reduced sustained outages in the LV network. The results showed that the benefit would be greatest for the MV case that is where the RTU is anticipated to contribute with most value. This analysis has only focused on one of the 23 benefits in the JRC model. If other of those benefits were to be included as well, e.g. reduced sustained outages and others, it is most likely that the overall benefits would be higher. It is further anticipated that other network company processes may benefit from the introduction of LV network monitoring, such as for instance Power Quality issues and network planning procedures, that additionally may even further increase the overall benefit. Another perspective would be to also include how the Smart Meters together with the RTUs could contribute to the benefit, as described in chapter under technical losses. Such an analysis would perhaps identify a larger volume of faults that could be qualified to be included in the analysis, as well as support activities in the general process in a positive way. Furthermore investments in and deployment of Smart Grid technology are not solely made out of direct benefits to the network operation but to a large extent also for improving the network services to the customer and the society as a whole. Such benefits are often regarded as quite substantial and, in the case of customer benefits, it is of uttermost importance to a network company to keep their customers satisfied. If this can be achieved by reducing outage time, etc, Smart Grid investments may be regarded as immensely beneficial to the image of the network company and consequently quite valuable. Replication, next steps and up scaling Replication and up scaling (exploitation) of the solution for Vattenfall is dependent on a) choice of strategy for LV monitoring, b) funding for the investment, c) LV SCADA/DMS system implementation in production system environment and d) process re-engineering and organisational change of work in the control center. Exploitation in line with the Demo2 technical solution will require full deployment of IEDs in secondary substations combined with new system interfaces between the Enterprise system EnergyIP MDMS and the IEDs, e.g. by integrating the MDMS with a LV SCADA and DMS system. This type of system functionality may also be supported by other system applications used in network operations. The choice of solution depends on the cost for development, implementation, license fees and access to the application by the different user groups within the DSO. Intellectual property (IP) Any IP rights are not identified for the DSOs, such rights are more of interest for system vendors and manufacturers of equipment. IP rights will be applicable for system application functionality as well as equipment design and functionality. In the Demo2 case this will be applicable for the ABB SCADA and DMS solution and the design of the secondary substation measurement solution. It will also be applicable for the emeter solution and configuration of the EnergyIP MDMS functionality, including the Analytics Foundation. Regulatory challenges The roll out of Smart Meters in Sweden was driven by new regulations in Conclusion and key messages The project operation has demonstrated a successful design of the technical solution in the secondary substations, where defined fault cases are successfully identified by the RTUs. Warning messages from both RTUs and Smart meters are sent to the overlying SCADA system. These messages are processed by the SCADA system and announced in the SCADA alarm lists and displayed in the DMS. 12

7 From the alarm lists in SCADA, the system functionality takes the user directly to the alarmed LV line in DMS, which is clearly marked in the user interface of the network topology. The DMS system can visualize the LV network at different zoom levels, where the most detailed level is at a single measuring point (residential meters). In EnergyIP MDMS in-depth analysis can be made using data from both RTUs and Smart meters. A general comment to the Demo2 results is that a Smart Grid concept for the LV monitoring may be shaped and created differently depending on the actual network situation. It is assumed that the RTU solution has greatest benefit in rural network areas. The simplified Business Case analyses, performed by Demo2, showed a potential benefit of 5-12 percent reduction of SAIDI for both MV and LV rural networks. A more advanced solution, i.e. increased investment per LV line, may improve SAIDI even more, but the improvement of SAIDI may not be correlated with the investment cost. The average number of faults per MV or LV feeder per year are not that many and the basic average Smart Grid investment cost per secondary substation today is substantial. The evaluation has shown that it is reasonable to assume that a large scale roll-out of the solution would first carefully analyse the quality of supply in the MV and LV networks in order to find those network areas where the benefit would be greatest. Also the most suitable level of technical solution needed will most probably be evaluated, e.g. for very small pole mounted secondary substations only monitor voltage and current on the LV side of the transformer and not on the individual LV line(s) or just use the AMR infrastructure. As a first step, the chosen level of Smart Grid solution is assumed to differ between rural and urban areas, types of secondary substations (pole mounted, larger ground stations, smaller kiosks etc) and retrofit installations versus deployment of new secondary substations etc. The future LV monitoring solution will contain a combination of different technical solutions, from only using the Smart meters to use advanced equipment in secondary substations and perhaps also downstream individual LV lines. Demo2 Challenges Conclusion Key Messages LV monitoring also support MV monitoring. Data collection using RTUs. Data collection using RTUs / Communication technology Solution is tested and verified. The LV failures, (phase faults) are detected and reported within seconds to the overlying SCADA system. 2G and 3G communication technology both support a Smart Grid solution for LV network monitoring. The solution has no battery back-up power, (no last gasp functionality). This is a limitation in the way that it could be difficult for an operator to determine if a warning is an outage or if it is only loss of communication. For uses such as maintenance and service of the RTUs it is far more efficient to use a faster 3G connection. This is also a good preparation for later stages where DSO s might want to pick up larger files from the IEC network in the secondary substation. ABB MicroSCADA Pro, Historian and LV DMS emeter EnergyIP MDMS Demonstrated applications for display of data, visualization of LV network monitoring as well as creation of reports and graphs for in-depth analysis. There is a potentially enormous amount of data provided by the components. Processing and display of data from both Smart meters and RTUs to support dynamic in-depth LV network Smart Grid analysis. By integrating Smart Meter measurement values and events, the system platform provides a powerful tool for LV network monitoring both at each outgoing LV line from the secondary substations as well as in the end of the line, on individual meter level. Carefully select the only needed data for analysis and visualization in order not to overload the operator with unwanted information, which in the worst case may obscure the potential problems from the Dispatch Center. The EnergyIP MDMS is a powerful tool for network optimization and maintenance analysis, supporting with dynamic findings by combining the data received from both RTUs, (secondary substations), and individual meters. 13 Demos Business Case analysis The Demo2 BC analysis for JRC reduced sustainable outage benefit showed an overall potential reduction of SAIDI with 5-12% improvement for both MV and LV network outage management. Table 7 - Technical Spotlight Demo2-1 conclusions and key messages This analysis only focused on one of the JRC defined benefits. A broadened scope would perhaps increase the benefit potential for LV network monitoring. Such an analysis should include other company processes and customer/ societal factors.

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia From INTEGRIS a solution architecture for energy smart grids Jean Wild - Schneider Electric

More information

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic

More information

Utilization of Automatic Meter Management in Smart Grid Development

Utilization of Automatic Meter Management in Smart Grid Development Utilization of Automatic Meter Management in Smart Grid Development Elenia Verkko Oy Ville Sihvola Head of Marketing and Sales ville.sihvola@elenia.fi Content of the presentation 1. What is Elenia Verkko

More information

How To Develop A Smart Grid In Elenia

How To Develop A Smart Grid In Elenia GEODE Autumn Seminar in Brighton 12 th of November Utilization of Automatic Meter Management in Smart Grid Development Ville Sihvola Head of Marketing and Sales Elenia Oy Elenia Oy Turnover 220 M Employees

More information

ADMS(Advanced Distribution Management System ) in Smart Grid

ADMS(Advanced Distribution Management System ) in Smart Grid ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution

More information

Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. sergio.fujii@areva-td.com. ethan.boardman@areva-td.com

Agenda do Mini-Curso. Sérgio Yoshio Fujii. Ethan Boardman. sergio.fujii@areva-td.com. ethan.boardman@areva-td.com Agenda do Mini-Curso Sérgio Yoshio Fujii sergio.fujii@areva-td.com Ethan Boardman ethan.boardman@areva-td.com Agenda do Mini-Curso Sistemas de Distribuição (DMS) Characteristics of Distribution Network

More information

Monitoring Underground Power Networks

Monitoring Underground Power Networks Monitoring Underground Power Networks By Mark Stiles Merve Cankaya ABSTRACT Underground electric distribution systems are common in large cities throughout the United States. Power usage for the entire

More information

Network Digitalisation Enel Point of View

Network Digitalisation Enel Point of View Network Digitalisation Enel Point of View Alessio Montone Smart Meter Solutions, Global Infrastructure & Networks Brussels, November 24 th, 2015 Enel Global Infrastructure & Networks Colombia 2,8 M customers

More information

Power products and systems. Intelligent solutions for power distribution Zone concept

Power products and systems. Intelligent solutions for power distribution Zone concept Power products and systems Intelligent solutions for power distribution Zone concept Securing continuous power supply ABB is one of the world's leading power and automation technology companies whose products,

More information

ICT Architecture for an Integrated Distribution Network Monitoring

ICT Architecture for an Integrated Distribution Network Monitoring INTEGRIS:INTElligentINTElligent GRId Sensor communications ICT Architecture for an Integrated Distribution Network Monitoring D. Della Giustina #, S. Repo, S. Zanini and L. Cremaschini # A2A RetiElettricheSpA

More information

Big data revolution Case LV Monitoring

Big data revolution Case LV Monitoring Big data revolution Case LV Monitoring Placing data collection, management, analysis and action at the heart of the smart utility Vattenfall Peter Söderström, Asset Development Manager, Vattenfall Distribution

More information

Executive summary 2. 1 Introduction 4

Executive summary 2. 1 Introduction 4 Flexible Networks for a Low Carbon Future Future Network Monitoring Strategy September 2015 Contents Executive summary 2 Glossary 3 1 Introduction 4 2 Fundamental principles of monitoring 5 2.1 LCT monitoring

More information

Electrical Network Management System

Electrical Network Management System Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement

More information

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A Roberts, T Berry, W D Wilson Schneider Electric Ltd, UK SYNOPSIS This paper describes the features of a modern Distribution

More information

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy

More information

Future grid infrastructure Field tests of LVDC distribution

Future grid infrastructure Field tests of LVDC distribution Future grid infrastructure Field tests of LVDC distribution LUT LVDC Research Group: Andrey Lana, Pasi Nuutinen, Antti Pinomaa, Tero Kaipia, Pasi Peltoniemi, Aleksi Mattsson, Jarmo Partanen Introduction

More information

AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation

AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation September 2010 Prepared for: By Sierra Energy Group The Research & Analysis Division of Energy Central Table of Contents Executive

More information

The calm after the storm

The calm after the storm The calm after the storm Human decision support in storm outage recovery Rafael Ochoa, Amitava Sen It s a fact of life that interruptions in an electrical distribution utility happen. Although they can

More information

AFRICAN UTILITY WEEK March 2011 Challenges with electricity supply: The role of the City of Cape Town

AFRICAN UTILITY WEEK March 2011 Challenges with electricity supply: The role of the City of Cape Town AFRICAN UTILITY WEEK March 2011 Challenges with electricity supply: The role of the City of Cape Town Alderman Clive Justus, Executive Mayoral Committee Member: Utility Services, City of Cape Town Content

More information

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility

More information

Test & Data Management Software

Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

DMS - Breakthrough Technology for the Smart Grid

DMS - Breakthrough Technology for the Smart Grid DMS - Breakthrough Technology for the Smart Grid The emerging smart grid is expected to address many of the current challenges in the electrical power industry. It is expected to make the electric grid

More information

Table of Contents. TransformerIQ FAQs 1

Table of Contents. TransformerIQ FAQs 1 [12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is

More information

Vattenfall Eldistribution AB, Sweden Project AMR Automatic Meter Reading

Vattenfall Eldistribution AB, Sweden Project AMR Automatic Meter Reading Vattenfall Eldistribution AB, Sweden Project AMR Automatic Meter Reading Toveiskommunikasjon i Norge 2008 21. mai 2008, Gardemoen, Oslo Fra planleggning til ferdig installasjon och drift Erik Nordgren

More information

Enel s experience on smart grids

Enel s experience on smart grids Enel s experience on smart grids Projects and Strategy Shenzhen, September 2014 Agenda Enel profile Overview of smart grid technologies Smart Grids and Smart Cities projects in Italy and Europe 2 Enel:

More information

Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution

Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution 138 Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure

More information

the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes.

the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes. Before the Department of Energy Washington, D.C. 20585 In the Matter of Implementing the National Broadband Plan by Studying the Communications Requirements of Electric Utilities To Inform Federal Smart

More information

Low Voltage Products

Low Voltage Products Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient

More information

TDMS Test & Data Management Software

TDMS Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

Scroll. An MDM (Metering Data Management) platform

Scroll. An MDM (Metering Data Management) platform Scroll An MDM ( Data Management) platform Overview Meter Data Management (MDM) has been traditionally defined as a repository for meter data collected from diverse meter collection systems as well as providing

More information

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe NETWORKS ESB Networks Response to ERGEG Consultation on Voltage Quality Regulation in Europe Date: 22 February 2007 Distribution System Operator ESB Networks Page 1 of 12 Contents 1.0 INTRODUCTION...3

More information

Market Growth and New Regulations Demand Network Modernization

Market Growth and New Regulations Demand Network Modernization CASE ESB NETWORKS: POLE TOP COMMUNICATION INCREASES EFFICIENCY IN IRELAND Viola s solution for remotely operating pole-top reclosers and switches increases reliability, cuts operating costs and helps to

More information

WELCOME. Landis+Gyr Technical Training Catalog

WELCOME. Landis+Gyr Technical Training Catalog WELCOME Training is essential to ensure the customer s success in implementing the Smart Grid Solution. Our goal at Landis+Gyr is to provide a foundation of knowledge that will allow personnel to quickly

More information

Smart Metering Initiative ADWEA Program

Smart Metering Initiative ADWEA Program Smart Metering Initiative ADWEA Program Saeed Nassouri Technical Advisor Abu Dhabi Water & Electricity Authority (ADWEA) Dec 2010 Company Background SMART GRID Basics AMI Project Strategy Project Scope

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Preparing for the Future: How Asset Management Will Evolve in the Age of the Smart Grid

Preparing for the Future: How Asset Management Will Evolve in the Age of the Smart Grid Preparing for the Future: How Asset Management Will Evolve in the Age of the Smart Grid Executive summary Most utilities struggle to organize information about their distribution network assets. Operations,

More information

Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution

Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution Data Center Solutions for Data Centers provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility operations. Gain

More information

Basics in Energy Information (& Communication) Systems Summary Substation Automation

Basics in Energy Information (& Communication) Systems Summary Substation Automation Basics in Energy Information (& Communication) Systems Summary Substation Automation Dr. Johann Pohany, xxxx x xxx xxx xx Substation Integration and Automation Levels Integrated utility business operation

More information

Power & Environmental Monitoring

Power & Environmental Monitoring Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

David Payne, P.E. Associate Director February 18, 2014

David Payne, P.E. Associate Director February 18, 2014 David Payne, P.E. Associate Director February 18, 2014 Overview of Texas A&M University State's first public institution of higher education, was opened on Oct. 4, 1876 as the Agricultural and Mechanical

More information

Addendum #2 Contract UK-11-13

Addendum #2 Contract UK-11-13 Addendum #2 Contract UK-11-13 Utilities Kingston Purchase and Replacement of Switchgear at Kingston Hydro Substation MS11 March 25, 2011 Delivered to: All RFP recipients Total number of pages: Nine (9)

More information

How To Choose A Transformer

How To Choose A Transformer Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV

More information

CenterPoint Energy Robert B. Frazier Director of Electric Technology

CenterPoint Energy Robert B. Frazier Director of Electric Technology Smart Grid The Texas Experience CenterPoint Energy Robert B. Frazier Director of Electric Technology WHO IS CENTERPOINT ENERGY? Public company traded on the New York Stock Exchange (CNP) Headquartered

More information

Substation Automation and Smart Grid

Substation Automation and Smart Grid GE Energy Substation Automation and Smart Grid John D. McDonald, P.E. GM, T&D Marketing IEEE PES Past President IEEE Division VII Director IEEE Fellow The Smart Grid POWERING POTENTIA L Current Situation

More information

Acting on the Deluge of Newly Created Automation Data:

Acting on the Deluge of Newly Created Automation Data: Acting on the Deluge of Newly Created Automation Data: Using Big Data Technology and Analytics to Solve Real Problems By CJ Parisi, Dr. Siri Varadan, P.E., and Mark Wald, Utility Integration Solutions,

More information

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1

More information

EC 350 Simplifies Billing Data Integration in PowerSpring Software

EC 350 Simplifies Billing Data Integration in PowerSpring Software White Paper EC 350 Simplifies Billing Data Integration in PowerSpring Software Executive Summary In the current energy environment, gas-metering data must be collected more frequently and in smaller increments

More information

2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System

2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System 2012 Smart Grid R&D Program Peer Review Meeting Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System James Stoupis ABB Inc., US Corporate Research Center

More information

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.

More information

Smart Grid - Big Data visualized in GIS

Smart Grid - Big Data visualized in GIS Smart Grid - Big Data visualized in GIS Maximizing Data Value with GIS and CIM in a Smart Grid World ESRI UC, San Diego, July 15 th 2014 Presenters from DONG Energy Signe Bramming Andersen, sigba@dongenergy.dk

More information

RUGGEDCOM NMS. Monitor Availability Quick detection of network failures at the port and

RUGGEDCOM NMS. Monitor Availability Quick detection of network failures at the port and RUGGEDCOM NMS is fully-featured enterprise grade network management software based on the OpenNMS platform. Specifically for the rugged communications industry, RNMS provides a comprehensive platform for

More information

Active Smart Grid Analytics Maximizing Your Smart Grid Investment

Active Smart Grid Analytics Maximizing Your Smart Grid Investment Itron White Paper Itron Enterprise Edition Meter Data Management Active Smart Grid Analytics Maximizing Your Smart Grid Investment Sharelynn Moore Director, Product Marketing Itron Stephen Butler Managing

More information

LTE Solution and Requirements for Smart Grids

LTE Solution and Requirements for Smart Grids 2014 年 11 月 10 日 星 期 一 LTE Solution and Requirements for Smart Grids 11 th November 2014 Markus Dillinger Head of Wireless Internet Technologies Huawei European Research Centre Munich, Germany Outline

More information

Substation Automation Systems. We are exceptional grid stability PSGuard Wide Area Monitoring System

Substation Automation Systems. We are exceptional grid stability PSGuard Wide Area Monitoring System Substation Automation Systems We are exceptional grid stability PSGuard Wide Area Monitoring System We are exceptional grid stability PSGuard Wide Area Monitoring System 2 We are exceptional grid stability

More information

Demand Response Management System Smart systems for Consumer engagement By Vikram Gandotra Siemens Smart Grid

Demand Response Management System Smart systems for Consumer engagement By Vikram Gandotra Siemens Smart Grid Demand Response Demand Response Management System Smart systems for Consumer engagement By Vikram Gandotra Siemens Smart Grid siemens.com/answers The Siemens Smart Grid Suite DRMS part of Grid Application

More information

New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems

New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems International Conference on Computer and Communication Engineering (ICCCE 2010), 11-13 May 2010, Kuala Lumpur, Malaysia New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System

More information

Monitoring & Control of Small-scale Renewable Energy Sources

Monitoring & Control of Small-scale Renewable Energy Sources Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,

More information

Comprehensive Asset Performance Management. Power Transmission and Distribution

Comprehensive Asset Performance Management. Power Transmission and Distribution Comprehensive Asset Performance Management Power Transmission and Distribution Comprehensive Asset Performance Management Siemens Asset Performance Management System (APMS) enables utilities to get the

More information

The Three Pillars for an Efficient AMI Operation

The Three Pillars for an Efficient AMI Operation The Three Pillars for an Efficient AMI Operation by Antonio Tortolero Gordillo Executive summary Implementing automated metering infrastructure (AMI) is a complex undertaking involving multiple technologies.

More information

The Role of INTEGRIS in the A2A Reti Elettriche sroadmap Toward the Smart Grid

The Role of INTEGRIS in the A2A Reti Elettriche sroadmap Toward the Smart Grid INTEGRIS:INTElligentINTElligent GRId Sensor communications The Role of INTEGRIS in the A2A Reti Elettriche sroadmap Toward the Smart Grid D. Della Giustina #, S. Zanini, S. Pugliese and L. Cremaschini

More information

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories: Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission

More information

The NES Smart Metering System. The World s Most Advanced Metering System Solution for the Smart Grid

The NES Smart Metering System. The World s Most Advanced Metering System Solution for the Smart Grid The NES Smart Metering System The World s Most Advanced Metering System Solution for the Smart Grid Making the Grid Smarter At Echelon, we believe the smart grid is an energy network. It includes not only

More information

BC Hydro. Electric Distribution System Cost of Service Study

BC Hydro. Electric Distribution System Cost of Service Study BC Hydro Electric Distribution System Reimer Consulting Group Inc. Arnie Reimer May 7, 2010 Table of Contents 1. Executive Summary... 3 2. BC Hydro Electric Distribution System... 4 2.1. General Description...

More information

An Alternative Approach to Improving SAIDI and SAIFI Indicators

An Alternative Approach to Improving SAIDI and SAIFI Indicators An Alternative Approach to Improving SAIDI and SAIFI Indicators Philippe Deschamps - Schneider Electric Industries - France Jean-Christophe Orsini - Schneider Electric Industries - France Kaare Seest Rasmussen

More information

Scania Fleet Management. because details matter. Scania Fleet Management. Scania Services. Dedicated all the way.

Scania Fleet Management. because details matter. Scania Fleet Management. Scania Services. Dedicated all the way. Scania Services. Dedicated all the way. Scania Fleet Management Scania Singapore Pte Ltd 40, Senoko Road Singapore 758112 Tel: +65 6861 9181 www.scania.com.sg 10.1% SPEED 13.5% IDLING 27508 KM DISTANCE

More information

The Data Management Challenge: Making Extremely Large Amounts of Data Useful and Actionable

The Data Management Challenge: Making Extremely Large Amounts of Data Useful and Actionable The Data Management Challenge: Making Extremely Large Amounts of Data Useful and Actionable Todd Pistorese OSIsoft 777 Davis Street San Leandro, CA 94577 Summary The introduction of AMI has created a data

More information

How To Manage Assets In Utilities

How To Manage Assets In Utilities Preparing for the Future: How Asset Management Will Evolve in the Age of Smart Grid By: Jeff Meyers, Smart Grid Solutions Telvent Utilities Group Table of Contents Introduction 3 The State of Asset Management

More information

Content. Research highlights and demonstrations

Content. Research highlights and demonstrations Content SGEM Overview Cleen Ltd Smart Grids is changing the way we do business Consortium and key facts Connection to other SG activities and standardization Phased evolution approach build on the Finnish

More information

Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure

Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure Hitachi Review Vol. 63 (2014), No. 1 18 Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure Kazuaki Iwamura Hideki Tonooka Yoshihiro Mizuno Yuichi Mashita OVERVIEW:

More information

Low Voltage Asset Management (LVAM) The key to reliable and safe electricity

Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Archie Jaykaran Distribution Division Eskom SA Contents Change drivers Scope, Approach, Project status LV Planning and Design

More information

Testing Intelligent Device Communications in a Distributed System

Testing Intelligent Device Communications in a Distributed System Testing Intelligent Device Communications in a Distributed System David Goughnour (Triangle MicroWorks), Joe Stevens (Triangle MicroWorks) dgoughnour@trianglemicroworks.com United States Smart Grid systems

More information

Preparing for Distributed Energy Resources

Preparing for Distributed Energy Resources Preparing for Distributed Energy Resources Executive summary Many utilities are turning to Smart Grid solutions such as distributed energy resources (DERs) small-scale renewable energy sources and energy

More information

Utilities the way we see it

Utilities the way we see it Utilities the way we see it Advanced Distribution Management Systems How to choose the right solution to improve your utility s safety, reliability, asset protection and quality of service Photo provided

More information

Industrial IT for Substation Automation & Protection

Industrial IT for Substation Automation & Protection Industrial IT for Substation Automation & Protection Exploit the potential of ABB substation automation Improve your performance In view of the increasingly competitive arena where power providers are

More information

White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid

White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid White Paper Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid Contents Executive Summary... 3 Integration of IT and OT... 4 Smarter Grid using Integrated

More information

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver www.siemens.com/fusesaver Siemens Fusesaver Highest availability and cost savings for your MV distribution network Answers for infrastructure and cities. 2 In high demand: An intelligent solution Improving

More information

BL20A0501 Electricity distribution technology. Introduction Jarmo Partanen

BL20A0501 Electricity distribution technology. Introduction Jarmo Partanen BL20A0501 Electricity distribution technology Introduction Jarmo Partanen Introduction to ED Prof. Jarmo Partanen, D.Sc Jukka Lassila Topics of lectures Introduction to Electricity Distribution, 27.10

More information

R&D in Vattenfall Johan Söderbom

R&D in Vattenfall Johan Söderbom R&D in Vattenfall Johan Söderbom Agenda 1 2 3 Vattenfall in brief R&D portfolio Smart Grids Vattenfall in brief Net sales 2011: 181 billion SEK (20 billion ) Electricity Generation: 166,7 TWh 7.8 million

More information

Energy Management System (EMS)

Energy Management System (EMS) Energy Management System (EMS) Comprehensive Power Quality Analysis Customer Billing and Invoicing at a Glance ExpertPower software solution provides comprehensive energy management, billing, demand response,

More information

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Case Study - University at Buffalo State University of New York Lower Energy Usage Costs with Real Time Monitoring, Campus-wide Reduce Energy Consumption through Awareness of Energy Use Analyze Power Quality

More information

Field Force Operational Data Visualization What s So Smart About It?

Field Force Operational Data Visualization What s So Smart About It? Field Force Operational Data Visualization What s So Smart About It? John J. Simmins, Ph.D. Electric Power Research Institute Smart Grid Information Sharing Call November 27, 2012 The self healing grid

More information

NetVision. NetVision: Smart Energy Smart Grids and Smart Meters - Towards Smarter Energy Management. Solution Datasheet

NetVision. NetVision: Smart Energy Smart Grids and Smart Meters - Towards Smarter Energy Management. Solution Datasheet Version 2.0 - October 2014 NetVision Solution Datasheet NetVision: Smart Energy Smart Grids and Smart Meters - Towards Smarter Energy Management According to analyst firm Berg Insight, the installed base

More information

PSS SINCAL - Overview -

PSS SINCAL - Overview - PSS SINCAL - Overview - PTI Day Buenos Aires, October 19/20, 2010 Dr. Michael Schwan,, Siemens PTI (Germany) www.siemens.com/energy/power-technologies PSS SINCAL Overview Page 3 Network Calculation Software

More information

Chapter 1. Network Structures

Chapter 1. Network Structures Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V

More information

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850 Relion Power system protection and automation reference Extending substation life cycle with IEC 61850 Extending substation life cycle with IEC 61850 A step-by-step power system retrofit approach for optimizing

More information

2010 SMART GRID INVESTMENTS INFORMATION TECHNOLOGY

2010 SMART GRID INVESTMENTS INFORMATION TECHNOLOGY EB-00-0 Exhibit G Tab Schedule Page of 00 SMART GRID INVESTMENTS INFORMATION TECHNOLOGY CUSTOMER PORTALS PILOT Customer Display Integration: The implementation of a customer display in the future is identified

More information

Smart Metering for Automatic Demand Response

Smart Metering for Automatic Demand Response Smart Metering for Automatic Demand Response Sanjeev K Rana TATA Power Delhi Distribution Limited METERING BILLING/CRM BANGKOK 08-May-2012 Agenda Company Overview Challenges in Indian Power Sector Need

More information

Paralleling Switchgear

Paralleling Switchgear Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more

More information

Key Considerations for Selecting an Energy Management System

Key Considerations for Selecting an Energy Management System www.siemens.com/sitecontrols Key Considerations for Selecting an Energy Management System How the right partner can deliver a fast ROI through significant annual energy and equipment maintenance savings.

More information

Generic strategy for CIM based systems integration for European distribution system operators

Generic strategy for CIM based systems integration for European distribution system operators Generic strategy for CIM based systems integration for European distribution system operators Andrej Souvent, EIMV Nejc Petrovič, Elektro Gorenjska, d.d. Eric Lambert, EDF R&D Starting points IT systems

More information

How the distribution management system (DMS) is becoming a core function of the Smart Grid

How the distribution management system (DMS) is becoming a core function of the Smart Grid How the distribution management system (DMS) is becoming a core function of the Smart Grid Reducing risks and costs by optimizing distribution network operations Abstract As utilities identify their components

More information

Smarten up your last mile

Smarten up your last mile Smarten up your last mile Solutions for smart metering and distribution network automation Answers for energy. Information is what really makes a difference Heading into the age of smart, transparent,

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

AMSC s Superconductor Cable Technologies for Electric Utilities

AMSC s Superconductor Cable Technologies for Electric Utilities International Workshop 2014 AMSC s Superconductor Cable Technologies for Electric Utilities Michael Ross, P.E. Managing Director of Superconductor Power Systems AMSC Corporate Facts Headquartered in MA,

More information

Wide Area Monitoring Current Continental Europe TSOs Applications Overview

Wide Area Monitoring Current Continental Europe TSOs Applications Overview Wide Area Monitoring Current Continental Europe TSOs Applications Overview Version 5 System Protection & Dynamics Working Group 20th September 2015 1. Content 1. Content... 2 2. Introduction... 3 3. Main

More information

Executive summary. by Michel Clemence, Renzo Coccioni, and Alain Glatigny

Executive summary. by Michel Clemence, Renzo Coccioni, and Alain Glatigny 998-2095-11-25-13AR0 by Michel Clemence, Renzo Coccioni, and Alain Glatigny Executive summary Annual electricity distribution losses average 4% in the European Union. These losses represent 7 billion Euros

More information

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP

More information