SOFTUNE REALOS CONFIGURATOR MANUAL
|
|
|
- Piers Williams
- 9 years ago
- Views:
Transcription
1 FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM E FR FAMILY F²MC FAMILY IN CONFORMANCE WITH µitron SPECIFICATIONS SOFTUNE REALOS CONFIGURATOR MANUAL
2
3 FR FAMILY F²MC FAMILY IN CONFORMANCE WITH µitron 3.0 SPECIFICATIONS SOFTUNE REALOS CONFIGURATOR MANUAL FUJITSU LIMITED
4
5 PREFACE Objectives and Intended Readership Trademarks Softune REALOS (hereafter called REALOS/FR) is a real-time operating system that runs on Fujitsu FR/F 2 MC-16/F 2 MC-8L family controllers and microcontrollers. The Softune REALOS/FR kernel specifications comply with the µitron 3.0 specifications. The Softune REALOS/907/896 kernel specifications comply with the µitron 2.0 specifications. This manual is intended for engineers who develop products using Softune REALOS. The manual describes the functions and operation of the Softune REALOS configurator. Read this manual as a reference. TRON is an abbreviation for The Real-time Operating system Nucleus. ITRON is an abbreviation of Industrial TRON. µitron is an abbreviation of Micro Industrial TRON. Microsoft, Windows, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. Other system names and product names in this manual are the trademarks of their respective companies or organizations. The symbols TM and are sometimes omitted in the text. i
6 Configuration of This Manual This manual consists of 3 parts. PART I PART II PART III Related Manuals Configurator Chapter 1 Notes on Use This chapter contains notes concerning the creation of application systems using the Configurator. Chapter 2 Overview of the Configurator This chapter provides an overview of the configurator. Chapter 3 Configuration Definition Statements This chapter describes the structure of and lists the configuration definition statements and explains them in detail. Non-Windows Version Chapter 4 Non-Windows Version Operations This chapter explains the operation of non-windows versions. Softune Workbench Version of the Configurator Chapter 5 Information for Softune Workbench Users This chapter provides an overview of the Workbench version of the configurator and contains notes on its use. Chapter 6 Operation of the Workbench Version of the Configurator This chapter explains how to operate the Softune Workbench version of the configurator. Chapter 7 Definition Dialogs of the Workbench Version of the Configurator This chapter explains the settings procedure and configuration of the Workbench configurator in the definition dialog. Chapter 8 Limitations of the Workbench Version of the Configurator This chapter explains the limitations on the Softune Workbench version of the configurator. Softune Assembler Manual Softune Linkage Kit Manual ii
7 1. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. 2. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. 3. The contents of this document may not be reproduced or copied without the permission of FUJITSU LIMITED. 4. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipments, industrial, communications, and measurement equipments, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. 5. Any semiconductor devices have inherently a certain rate of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. 6. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Control Law of Japan, the prior authorization by Japanese government should be required for export of those products from Japan FUJITSU LIMITED Printed in Japan iii
8 Softune REALOS manual set The REALOS manual set consists of the three volumes listed below. A first-time user of REALOS should first read the FR Family Softune REALOS User's Guide. FR Family Softune REALOS/FR/907/896 User's Guide This manual contains the following items: product installation procedure, application system creation procedure, notes on the system, and debugging macro commands used to debug applications on REALOS with the debugger. FR Family Softune REALOS/FR/907/896 Kernel Manual This manual contains information required to create user programs. Softune REALOS Configurator Manual This manual explains the REALOS configurator functions and how to use them. Softune REALOS/FR/ 907 Analyzer Manual Please refer to Kernel Manual. iv
9 READING THIS MANUAL Page Layout In this manual, an entire section is presented on a single page or spread whenever possible. The reader can thus view a section without having to flip pages. The content of each section is summarized immediately below the title. You can obtain a rough overview of this product by reading through these summaries. Also, higher level section headings are given in lower sections so that you can know to which section the text you are currently reading belongs without referring to the table of contents or the cover of each chapter. Products names Product names in this manual are abbreviated as follows: Microsoft Windows 95 operating system: Windows 95 Microsoft Windows NT Workstation operating system Version 4.0: Windows NT 4.0 Notation Used in This Manual The following notation is used in this manual to represent definition statement description formats, etc. Symbol Meaning [ ] Indicates that the elements within the square brackets [ ] may be omitted. { } Indicates a choice of one of the elements within the brackets { }. Separates elements in the description. Indicates that the preceding item may be written repeatedly. Note: Indicates an item that requires special attention. Always read these notes carefully. v
10 MEMO vi
11 CONTENTS PART 1 CONFIGURATOR... 1 CHAPTER 1 NOTES ON USE Notes on the Creation of Configuration Data Notes on the Configuration Process Notes on the Softune Workbench Version of the Configurator... 7 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR What Is the Configurator? Positioning of the Configurator Configurator Functions Defining Configuration Data Executing the Configuration Process Creating Absolute Format Object Files with the Softune Workbench Version Configuration Data (FR Family) CPU Definition (FR) Linkage Definition (FR) System Definition (FR) Memory Definition (FR) System Call Definition (FR) Task Definition (FR) Common Stack Definition (FR) Semaphore Definition (FR) EventFlag Definition (FR) Mailbox Definition (FR) Variable-size MemoryPool Definition (FR) Fixed-size MemoryPool Definition (FR) Vector Definition (FR) Configuration Date (F²MC-16 Family) CPU Definition (F²MC-16) Linkage Definition (F²MC-16) System Definitions (F²MC-16) Memory Definitions (F²MC-16) Task Definitions (F²MC-16) Common Stack Definitions (F²MC-16) Semaphore Definitions (F²MC-16) Eventflag Definitions (F²MC-16) Mailbox Definitions (F²MC-16) Fixed-Size MemoryPool Definitions (F²MC-16) Vector Definitions (F²MC-16) vii
12 2.6 Configuration Data (F²MC-8L Family) CPU Definition (F²MC-8L) Linkage Definition (F²MC-8L) System Definitions (F²MC-8L) Memory Definitions (F²MC-8L) Task Definitions (F²MC-8L) Common Stack Definitions (F²MC-8L) Semaphore Definitions (F²MC-8L) Eventflag Definitions (F²MC-8L) Mailbox Definitions (F²MC-8L) Vector Definitions (F²MC-8L) CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Overview of the Configuration Definition Statements Definition Statement Explanation CPU RELOCATE_FILE LIBRARY_FILE ABSOLUTE_FILE MAP_FILE CYC_HDR_NUMBER ALM_HDR_NUMBER EXC_HDR_ENTRY CPU_EXTHDR_ENTRY SYS_EXTHDR_ENTRY SCAL_EXC_ENTRY PRIORITY_LEVEL INCLUDE ILM CODE SYS_CLOCK CONTEXT_REGISTER REGISTER_BANK wai_tsk SYS_STK_SIZE ROM RAM KNL_ROM KNL_RAM USR_SECTION SYSTEM_CALL TSK COM_STACK SEM_ICNT SEM viii
13 FLG_BIT FLG_PATTERN FLG MBX MPL MPF EIT_ENTRY INIT_HDR_ENTRY CALL_ENTRY RESET_ENTRY PART 2 NON-WINDOWS VERSION CHAPTER 4 OPERATION OF THE NON-WINDOWS VERSION Configurator Startup Command Option for the Monitor Debugger PART 3 SOFTUNE WORKBENCH VERSION OF THE CONFIGURATOR CHAPTER 5 INFORMATION FOR SOFTUNE WORKBENCH USERS Outline of the Workbench Version of the Configurator CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR Starting the Workbench Version of the Configurator Starting the Configurator with a New Configuration File Starting the Configurator by Using an Existing Configuration File Editing the Configuration File Making a Project CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Definition Dialog Organization Types of Dialog List of File Names File Selection Miscellaneous Lists System Definition Dialog Memory Definition Dialog System Call Definition Dialog Task Definition Dialog Task Detail Definition Dialog Common Stack Definition Semaphore Definition Dialog EventFlag Definition Dialog ix
14 7.8 Mailbox Definition Dialog Variable-Size MemoryPool Definition Dialog Fixed-Size MemoryPool Definition Dialog Vector Definition Dialog CPU Setup Dialog Debug Setting Dialog CHAPTER 8 LIMITATIONS ON THE WORKBENCH VERSION OF THE CONFIGURATOR Maximum Number of Definable Objects (FR) APPENDIX Appendix A Notes on Using the Configurator Appendix B Kernel Code and Kernel Data Allocation Appendix C Configurator Error Messages Appendix D Dialog List INDEX x
15 FIGURES Figure 2.2 Configurator Positioning...11 Figure Defining Configuration Data...13 Figure Executing the Configuration Process...14 Figure Creating Absolute Format Object Files (Softune Workbench Version)...16 Figure Vanable-size MemoryPool Total Size/Number of Blocks...32 Figure Vanable-size MemoryPool Total Size/Number of Blocks...34 Figure Total size of fixed-size memorypool/block size...53 Figure Status Transition of the System Clock Handler...98 Figure Example Where the Common Stack Cannot Function Properly Figure 4.1a Configuration Definition Statements Figure 4.1b Output Example of an Interrupt Vector Table Figure 4.1c Output Example of a Jump Table Figure 5.1a [Create New Project] dialog.(fr) Figure 5.1b Example of the System Definition Dialog (FR) Figure 5.1c Example of Displaying Help Information about a System Call with a Single Operation..160 Figure 5.1d Relationship of Softune Workbench and REALOS Figure 6.1.1a Example of the Softune Workbench Main Window (FR) Figure 6.1.1b Example of the [New] Dialog of Softune Workbench Figure 6.1.1c Example of the [Create New Project] Dialog of Softune Workbench Figure 6.1.1d Example of the [Create Configuration File] Dialog Figure 6.1.1e Example of the [System] Dialog (FR) Figure 6.1.1f Example of the Warning Message Figure 6.1.2a Example of the [Create Configuration File] Dialog Figure 6.1.2b Example of the [Set Configuration File] Dialog Figure 6.1.2c Example of the Warning Message Dialog Figure 6.2a Example of the Softune Workbench Project Window Figure 6.2b Example of the [Set Configuration File] Dialog Figure 6.3a Example of the [Add Member] Menu Item of Softune Workbench Figure 6.3b Example of the [Add Member] Dialog Figure 6.3c Example of the [Build] Menu Item of Softune Workbench Figure 6.3d Example of Compilation and Linkage Execution Results Figure 7.1a Example of the Wizard Dialogs Figure 7.1b Example of the Tabbed Dialogs Figure Example of a List of File Names Figure Example of a Miscellaneous List xi
16 Figure 7.2a Example of the System Definition Dialog (FR) Figure 7.2b Example of the System_1 Definition Dialog (16) Figure 7.2c Example of the System_2 Definition Dialog (16) Figure 7.2d Example of the Save and Restore Register Selection Dialog (16) Figure 7.2e Example of the System Definition Dialog (8L) Figure 7.3a Memory Definition Dialog (FR) Figure 7.3b Memory Definition Dialog (16) Figure 7.3c Memory Definition Dialog (8L) Figure 7.4a Example of the System Call Definition Dialog (FR) Figure 7.4b Example of the Task Management Function Definition Dialog (FR) Figure 7.5a Example of the Task Definition Dialog (FR) Figure 7.5b Example of the Task Definition Dialog (16) Figure 7.5c Example of the Task Definition Dialog (8L) Figure 7.5.1a Example of the Task Detail Definition Dialog (FR) Figure 7.5.1b Example of the Task Definition Dialog (16) Figure 7.5.1c Example of the Task Definition Dialog (8L) Figure Example of the Common Stack Definition Dialog (Common) Figure 7.6a Example of the Semaphore Definition Dialog (FR) Figure 7.6b Example of the Semaphore Definition Dialog (16) Figure 7.6c Example of the Semaphore Definition Dialog (8L) Figure 7.7a Example of the EventFlag Definition Dialog (FR) Figure 7.7b Example of the EventFlag Definition Dialog (16) Figure 7.7c Example of the EventFlag Definition Dialog (8L) Figure 7.8a Example of the Mailbox Definition Dialog (FR) Figure 7.8b Example of the Mailbox Definition Dialog (16) Figure 7.8c Example of the Mailbox Definition Dialog (8L) Figure 7.9a Example of the Variable-Size MemoryPool Definition Dialog (FR) Figure 7.10a Example of the Fixed-Size MemoryPool Definition Dialog (FR) Figure 7.10b Example of the Fixed-Size MemoryPool Definition Dialog (16) Figure 7.11a Example of the Vector Definition Dialog (FR) Figure 7.11b Example of the Vector Definition Dialog (16) Figure 7.11c Example of the Vector Definition Dialog (8L) Figure 7.12a Example of the CPU Setup Dialog (16) Figure 7.12b Example of the CPU Setup Dialog (8L) Figure 7.13a Example of the Debug Definition Dialog (FR ) Figure 7.13b Example of the Debug Setting Dialog (16) Figure D.a Example of the Warning Dialog Figure D.b Example of the Error Dialog xii
17 TABLES Table List of System Calls...22 Table 3.1a List of Configuration Definition Names...70 Table 3.1b List of Configuration Definition Names [16]...71 Table 3.1c List of Configuration Definition Names [8L]...73 Table a Generating the System Clock Handler Return [16]...98 Table b Generating the System Clock Handler Return [8L]...99 Table B.a FR Family Kernel Code Section and Kernel Data Section Table B.b F²MC-16 Family Kernel Code Section and Kernel Data Section Table B.c F²MC-8L Family Kernel Code Section and Kernel Data Section Table B.d Formulas for Calculating Kernel Management Areas for the FR Family Table B.e Formulas for Calculating Kernel Management Areas for the F²MC-16 Family Table B.f Formulas for Calculating Kernel Management Areas for the F²MC-8L Family Table B.g Kernel and Task Memory Size Calculation (FR Family) Table B.h Kernel and Task Memory Size Calculation (F²MC-16 Family) Table B.i Kernel and Task Memory Size Calculation (F²MC-8L Family) xiii
18 MEMO xiv
19 PART 1 CONFIGURATOR Part I provides an overview of the configurator and explains the configuration definition statements that are common to both the Windows/non-Windows versions. Chapter 1 Notes on Use Chapter 2 Overview of the Configurator Chapter 3 Configuration Definition Statements 1
20 MEMO 2
21 CHAPTER 1 NOTES ON USE This chapter contains notes concerning the creation of application systems using the configurator. 1.1 Notes on the Creation of Configuration Data 1.2 Notes on the Configuration Process 1.3 Notes on the Softune Workbench Version 3
22 CHAPTER 1 NOTES ON USE 1.1 Notes on the Creation of Configuration Data This section contains notes on the creation of configuration data. Notes on the Creation of Configuration Data Note: Exception handler It is necessary to define an exception handler in order to execute suitable exception processing and then continue normal processing if a CPU exception occurs in the target system. (->See the definition statement EXC_HDR_ENTRY.) If a CPU exception is generated without an exception handler having been defined, the user s system down processing may be executed and the target system may not be able to continue with its processing correctly. Interrupt handlers Interrupt handlers must be defined for all interrupts that are generated in the target system. (->See the definition statement EIT_ENTRY.) If an interrupt for which no interrupt handler is defined occurs, the target system cannot continue its processing correctly. System stack size The system stack is used by the kernel and by the interrupt handler. Define the system stack size with plenty of space. (->See the definition statement SYS_STK_SIZE.) If the system stack size is insufficient, the target system will not operate correctly. Task stack size Define the task stack size with plenty of space. (->See the definition statements TSK and COM_STACK.) If the task stack size is insufficient, the target system will not operate correctly. 4
23 1.1 Notes on the Creation of Configuration Data Common stack When two or more tasks that share the same common stack are simultaneously in the READY, WAIT, or other non-dormant state, the target system cannot operate normally. Simultaneously operating tasks must use different common stacks or refrain from using common stacks. (->See the definition statement COM_STACK.) Section arrangement If areas or addresses designated by the KNL_RAM, KNL_ROM, and USR_SECTION definition statements overlap, the sections may be arranged incorrectly. After configuring, verify the output map file or check whether the sections are arranged properly, which include standard in the linkage kit. 5
24 CHAPTER 1 NOTES ON USE 1.2 Notes on the Configuration Process This section contains notes on the configuration process. Notes on the Configuration Process Note: CTRL-C Do not forcibly terminate the configuration process by pressing CTRL-C (pressing the C key while holding down the CTRL key). If CTRL-C is pressed, the Configurator may not operate correctly. Configurator startup name To start the configurator from the DOS prompt in Windows 95/NT, execute frcfs.exe. ( -> See Appendix A, Notes on Using The configurator. ) Using file names and directory names Do not use 2-byte characters in a file name or directory name used by the configurator. If 2-byte characters are specified in a file name or directory name, the configurator may not operate correctly. When installing the configurator, do not use 2-byte characters in the installation directory name. If the configurator is installed using 2-byte characters in the directory name, it may not operate correctly. 6
25 1.3 Notes on the Softune Workbench Version of the Configurator 1.3 Notes on the Softune Workbench Version of the Configurator This section contains notes on the Softune Workbench version of the configurator. Notes on the Softune Workbench version of the configurator Note: REALOS configurator add-in module for Softune Workbench Softune REALOS Configurator is a REALOS function expansion module for Softune Workbench. The module is in the form of a dynamic link library (DLL) form, allowing it to be linked dynamically with Softune Workbench. Softune Workbench itself has no REALOS support function. If, however, Softune REALOS is installed, Softune Workbench is automatically expanded so that the REALOS support function can be used. Before using the Softune Workbench version of the configurator Before using the Softune Workbench version of the configurator, read Chapters 5 and 6 in Part III. Setting ROM and RAM If a new configuration file is created by the Workbench version of the configurator, set the ROM/RAM area with the link option setting from [Project]-[Tool Option Setting] in Softune Workbench. Setting the relocatable object file and library file If the configurator is activated and saved using an existing configuration file when a new project is created, the relocatable object file and library file in the existing configuration file are not registered in Softune Workbench. Register the source file or library file from [Project]-[Member Addition] in Softune Workbench. Comment lines in an existing configuration file If a configuration file containing comment lines is loaded and then saved, the comment lines do not remain in the configuration file. 7
26 MEMO 8
27 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR This chapter provides an overview of the configurator. 2.1 What Is the Configurator? 2.2 Positioning of the Configurator 2.3 Configurator Functions 2.4 Configuration Data (FR Family) 2.5 Configuration Data (F 2 MC-16 Family) 2.6 Configuration Data (F 2 MC-8L Family) 9
28 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR 2.1 What Is the Configurator? The configurator is a tool that is used to construct REALOS/FR systems. After assembling or compiling the tasks, handlers, etc., the user uses the configurator to define the REALOS/FR system configuration data. Using this system configuration data, the configurator allocates the initial data and work areas that are needed in order for the REALOS/FR system to run, and also conditionally assembles the kernel source code in order to create a kernel that is optimized for the user application system. What is the Configurator? The configurator creates an absolute format object file by linking together kernel objects, user relocatable objects defined by the user, and libraries. This data that is essential to system construction is called configuration data, the data format that is used to store configuration data in files is called the configuration definition statement, and a file in which configuration definition statements are written is called a configuration file. The configurator can read INCLUDE files. Just like configuration files, INCLUDE files contain configuration data that is necessary for system construction. Configuration file INCLUDE file1.rcf Configuration data INCLUDE file2.rcf Configuration data INCLUDE file file1.rcf Configuration data Configuration data file2.rcf Configuration data Configuration data Configuration data 10
29 2.2 Positioning of the Configurator 2.2 Positioning of the Configurator Executing the configurator creates an absolute format object file. Positioning the Configurator Executing the configurator creates an absolute format object file consisting of the kernel and a user program linked into one. (See Figure 2.2.) User source file User source file Language processor Language processor Relocatable object file Relocatable object file Librarian Kernel source/ object file User library file Configurator Configuration file Absolute object file Map file Target system Figure 2.2 Configurator Positioning 11
30 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR 2.3 Configurator Functions The configurator functions can be broadly divided into two types: Configuration data definition Configuration execution Configurator Functions Configuration data definition With the Softune Workbench version, it is easy to define the configuration data (from the Windows environment). The defined configuration data is saved as a text file, so it can be edited with a text editor, etc. For details, see Section Defining Configuration Data. Configuration execution The Configurator generates the optimum kernel for the user system and various required data in accordance with the user-defined configuration data. It also links the kernel to a user application file. Therefore, an absolute object file generated by the Configurator can be incorporated into the system. For details see Section Configuration Execution, Section Absolute Object File Generation with Softune Workbench Version. 12
31 2.3.1 Defining Configuration Data 2.3 Configurator Functions Configuration data can be easily defined by using the Softune Workbench version of the configurator. Defining Configuration Data When the Softune Workbench version is used, it is easy to define configuration data (from the Windows environment). The defined configuration data is saved as a text file, so it can be edited with a text editor, etc., (Figure 2.3.1). For the configuration data format, see Chapter 3 Configuration Definition Statements. For the Softune Workbench version, see Part III, Softune Workbench Version. Window-based environment Store Read Configuration file Store Read Read Configurator (Softune Workbench version) Non-window-based environment Text editor Configurator Figure Defining Configuration Data 13
32 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Executing the Configuration Process The configurator generates an absolute format object file on the basis of the configuration data. Executing the Configuration Process The configurator creates an absolute format object file by linking the kernel object, the user relocatable object, and the user library that were all created on the basis of data described in the configuration file. (See Figure ) The configurator starts up the assembler and the linker. Therefore, before starting up the configurator, it is necessary to define the directory where the tools are stored in the environment variable PATH. (User input file) User relocatable object User library Configuration file Configurator Internal processing Embedded version Evaluation version Kernel data file Kernel source file Kernel object file Assembler For F 2 MC-16/8L Kernel object file Librarian Kernel library file Linker Absolute object file Map file : The assembler and linker are started up by the configurator automatically. Figure Executing the Configuration Process 14
33 2.3 Configurator Functions The configurator has two operating modes. For details on the differences among the three modes and how to specify each of the modes, see Section 4.1, Configurator Startup Command. 15
34 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Creating Absolute Format Object Files with the Softune Workbench Version The configurator section is executed automatically when an absolute format object file is created by the Windows version of the configurator. Creating Absolute Format Object Files with the Softune Workbench Version The MS-DOS prompt version of the configurator (frcfs.exe) is automatically executed when an absolute format object file is generated by the Softune Workbench version of the configurator. Because the MS-DOS prompt version of the configurator starts the assembler, when an absolute format object file is generated, the directory where the various tools are stored must be defined in the PATH environment variable. For details on the Softune Workbench version of the configurator, see Part III, Softune Workbench Version of the Configurator. User relocatable object Configuration file Softune Workbench version Internal processing (Definition/changes) (User input file) Configuration file Internal processing Configurator Created when a definition/change is made in the Softune Workbench version. Started inside the Softune Workbench version. Data file Assembler For F 2 MC-16/8L Started inside the configurator. Object file Librarian Object file Linker Started inside the Softune Workbench version. Absolute object file Map file Figure Creating Absolute Format Object Files (Softune Workbench Version) 16
35 2.4 Configuration Data (FR Family) 2.4 Configuration Data (FR Family) The configurator constructs a system based on the configuration data that was input from the configuration file. This section describes the rules, notes, restrictions, etc., that apply to the definition of configuration data. Configuration Data There are 13 types of configuration data definitions in the FR: CPU definition Linkage definition System definition Memory definition System call definition Task definition Common stack definition Semaphore definition Eventflag definition Mailbox definition Variable-size memorypool definition Fixed-size memorypool definition Vector definition For details on each definition, see Sections 2.4.1, CPU Definition, to , Vector Definition. 17
36 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR CPU Definition (FR) The CPU definition specifies the target CPU using its MB number. CPU definition Specify the target CPU of the program that performs configuration using its MB number. An error occurs if a CPU that cannot be selected is specified. 18
37 2.4.2 Linkage Definition (FR) 2.4 Configuration Data (FR Family) The linkage definition defines the following four items: Relocatable object names Library names Absolute object name Map file output Linkage Definition Relocatable object names Specify the names of the user's relocatable objects for the relocatable object names. The file names can be specified either with an absolute path specification or a relative path specification. Library names For the library name specification, specify the names of the libraries that the user program uses. The file names can be specified either with an absolute path specification or a relative path specification. Absolute object name Specify the name of the absolute object that was output when the configuration process was executed. Map file output Specify whether or not a map file is to be output. The map file is output to the current directory under the file name created by adding the extension.mp1 to the absolute object name. For example, if the absolute object name is realos.abs, the map file name will be realos.mp1. The map file can be used to check the list of options that have been sent to the linker by the configurator and the list of sections that have been allocated. 19
38 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR System Definition (FR) The system definition defines the following four items: Number of cyclic activation handlers/number of alarm handlers Exception handler definition Priority level INCLUDE file names System Definition Number of cyclic activation handlers/number of alarm handlers Specify the number of cyclic activation handlers and alarm handlers to be used by the user. Because the amount of memory used increases as this number increases, specify the required number. (The amount of memory used for the cyclic activation handlers and alarm handlers is listed below.) The range of values that can be specified is from 0 to If this specification is omitted, 0 is assumed. Object name Amount of memory used Cyclic activation handler 28 x number of handlers Alarm handler 28 x number of handlers (Unit: Bytes) Exception handler definition Specify the system call and CPU exception handler entry by means of a label or address. If this specification is omitted, the exception handler is not embedded. Priority level Specify the minimum priority for tasks used by the user system. The priority level that can be specified ranges from 8 to 32. If this specification is omitted, 32 is assumed to have been specified when the configuration process is executed. If the priority level decreases, the amount of memory used increases. Use the setting that is appropriate for the system. INCLUDE file names Specify the names of the configuration files that are to be included. Use INCLUDE file names when splitting the configuration file into two or more files. INCLUDE files cannot be nested. 20
39 2.4.4 Memory Definition (FR) 2.4 Configuration Data (FR Family) The memory definition defines the following three items. System stack Memory type and range Section names/addresses Memory Definition System stack The system stack is used by the kernel and interrupt handlers. Specifiable sizes are multiples of four bytes,. The minimum is 256 bytes. If this specification is omitted, the default is 1024 bytes. Memory type and range Set the ROM and RAM areas that can be allocated for the target. Based on this setting, the linker allocates the area automatically. Kernel code (including data such as initial values) is located contiguously at the address defined as the kernel data address. Data managed by the system (such as OS data and memorypools) is located contiguously at the address defined as the kernel data address. If the kernel code address and kernel data address are omitted, location is done automatically based on the specified ROM and RAM areas. Specify an address that is a multiple of four as the start address. Section names/addresses Specify all of the section names used by the user program and the addresses where those sections are to be located. If the address specification is omitted, each section is located after the previously specified section. Therefore, the address specification cannot be omitted for the first section that is specified. It is essential to note that the linker returns an error when a nonexistent section is defined. For the kernel data addresses, see Appendix B. 21
40 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR System Call Definition (FR) The system call definition defines the system calls that are used by the user program. System Call Definition The system call definition defines the system calls that are used by the user program. Define all of the system calls that are to be used. Defining the system calls that are to be used makes it possible to optimize the kernel code size, since no unnecessary modules are embedded. Table lists the system calls that can be selected. Table List of System Calls Function name TSK TSYNC SEM FLG MBX INT MPL MPF TIM SYS System call name sta_tsk ext_tsk ter_tsk dis_dsp ena_dsp chg_pri rot_rdq rel_wai get_tid ref_tsk sus_tsk rsm_tsk frsm_tsk slp_tsk tslp_tsk wup_tsk can_wup sig_sem wai_sem preq_sem ref_sem set_flg clr_flg wai_flg pol_flg ref_flg snd_msg rcv_msg prcv_msg ref_mbx ret_int loc_cpu unl_cpu chg_ilm ref_ilm get_blk pget_blk rel_blk ref_mpl get_blf pget_blf tget_blf rel_blf ref_mpf set_tim get_tim dly_tsk def_cyc act_cyc ref_cyc def_alm ref_alm ret_tmr get_ver ref_sys 22
41 MEMO 23
42 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Task Definition (FR) The task definition defines the following eight items: Task name Task entry Task startup priority Task stack size Task attributes Task start code Task ID Extended information Object wait function with task time-out Task Definition Task name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here is as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When writing code that references an ID number, using this object name is recommended. Task entry Specify the task entry with a label or an address. Task startup priority Specify the priority of the task when it is started up. Specify a priority that is higher than the minimum priority specified by the priority level. If this specification is omitted, the minimum priority is assumed. Task priority 1 Task startup priority Minimum priority 32 High Priority Low Priorities within this range can be used. However: 8 Minimum priority 24
43 2.4 Configuration Data (FR Family) Task stack size Specify either the stack size used by the task, or a common stack name. Specify the size as a multiple of four bytes, with a minimum of 96 bytes. If this specification is omitted, a specification of 1024 bytes is assumed. The stack size for a user task written with C language functions can be roughly determined by using the Softune C analyzer. However, it may be necessary to increase the specified amount (96 bytes) used for the task context. For details on common tasks, see Section 2.4.7, Common Stack Definition. Task attributes Specify the state at system startup of the task being defined. If this specification is omitted, DORMANT is assumed. Task start code Specify the task start code. This value is passed to the task when the task is started up. If this specification is omitted, 0 is assumed. Task ID Object IDs are used to specify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage would generate an error since ID number 3 is not being used. Extended information 32 bits of data that the user can use in any manner desired can be specified, either by a numeric value or a label. This information can be referenced by system call ref_tsk. Object wait function with task time-out Specify whether the object wait function with a task time-out is allowed. If this specification is omitted, the object wait function with a task time-out cannot be used. The object wait system call with a time-out function (twai_sem, twai_flg, trcv_msg, and tget_blf) can be used only by a task for which the use of the object wait function with a task time-out is allowed. This rule, however, does not apply to the tslp_tsk and dly_tsk system calls. 25
44 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Common Stack Definition (FR) The common stack definition defines a stack that can be shared by multiple tasks. Common Stack Definition By specifying a common stack, it becomes possible for multiple tasks to use the same stack. A common stack is created by specifying a stack name and size. A task can use a common stack by specifying the name of the common stack in place of the stack size. Specify the size as a multiple of four bytes, with a minimum of 96 bytes. If this specification is omitted, a specification of 1024 bytes is assumed. Note: When multiple tasks that are sharing a stack (using the same common stack) are in a state other than the DORMANT state (READY, WAIT, etc.) simultaneously, the target system will not operate correctly. Tasks that operate simultaneously must either use different common stacks or else must not use common stacks. [Example where correct operation is possible] [Example where correct operation is not possible] Task A Task B Task A Task B READY DORMANT READY WAIT Using the common stack Not using the common stack Using the common stack Using the common stack Common stack I Common stack I 26
45 MEMO 27
46 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Semaphore Definition (FR) The semaphore definition defines the following five items: Semaphore name Semaphore initial count Semaphore count maximum Semaphore ID Extended information Semaphore Definition Semaphore name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here is as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When writing code that references an ID number, using this object name is recommended. Semaphore initial count Specify the semaphore count at system startup as a value in the range from 0 to Specify a value for the initial count that is equal to or less than the semaphore count maximum. If this specification is omitted, 1 is assumed. Semaphore count maximum Specify the maximum semaphore count that the system can use as a value in the range from 0 to An error results if a count value that is greater than the maximum specified here is used. If this specification is omitted, is assumed. Semaphore count 0 Initial count Maximum This is the range of semaphore counts that can be used. Semaphore ID Object IDs are used to specify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. 28
47 2.4 Configuration Data (FR Family) ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage would generate an error since ID number 3 is not being used. Extended information 32 bits of data that the user can use in any manner desired can be specified, either by a numeric value or a label. This information can be referenced by system call ref_sem. 29
48 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR EventFlag Definition (FR) The eventflag definition defines the following four items: Eventflag name Eventflag initial pattern Eventflag ID Extended information EventFlag Definition Eventflag name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here is as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When writing code that references an ID number, using this object name is recommended. Eventflag initial pattern Specify the eventflag bit pattern at system startup as a 32-bit value in the range from 0 to 0xFFFFFFFF. If this specification is omitted, 0 is assumed. Eventflag ID Object IDs are used to specify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage would generate an error since ID number 3 is not being used. Extended information 32 bits of data that the user can use in any manner desired can be specified, either by a numeric value or a label. This information can be referenced by system call ref_flg. 30
49 Mailbox Definition (FR) 2.4 Configuration Data (FR Family) The mailbox definition defines the following three items: Mailbox name Mailbox ID Extended information Mailbox Definition Mailbox name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here is as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When writing code that references an ID number, using this object name is recommended. Mailbox ID Object IDs are used to specify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage would generate an error since ID number 3 is not being used. Extended information 32 bits of data that the user can use in any manner desired can be specified, either by a numeric value or a label. This information can be referenced by system call ref_mbx. 31
50 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Variable-size MemoryPool Definition (FR) The Variable-size memorypool definition defines the following four items: Variable-size Memorypool name Variable-size Memorypool total size/number of blocks Variable-size Memorypool ID Extended information Variable-size MemoryPool Definition Variable-size Memorypool name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here is as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When writing code that references an ID number, using this object name is recommended. Variable-size Memorypool total size/number of blocks Assuming m as the size of one variable-size memorypool block, n as the number of blocks, and M as the total size of the variable-size memorypool, then n = M/m. (See Figure ) However, m must be a multiple of four bytes, with a minimum of 20 bytes. Overall memorypool Block 1 Area of m bytes Block 2 Area of M = m x n bytes Block n Example of variable-size memorypool with block size m and number of blocks n Figure Vanable-size MemoryPool Total Size/Number of Blocks In addition to the variable-size memorypool area, the memory block management area is required as an area used for variable-size memorypool management. The variable-size memorypool area and the memory block management area are automatically allocated from the area specified by the definition statement KNL_RAM. 32
51 2.4 Configuration Data (FR Family) Variable-size Memorypool ID Object IDs are used to specify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage would generate an error since ID number 3 is not being used. Extended information 32 bits of data that the user can use in any manner desired can be specified, either by a numeric value or a label. This information can be referenced by system call ref_mpl. 33
52 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Fixed-size MemoryPool Definition (FR) The fixed-size memorypool definition defines the following four items: Fixed-size memorypool name Number of fixed-size memorypool blocks and block size Fixed-size memorypool ID Extended information Fixed-size memorypool definition Fixed-size memorypool name An object ID number is assigned for an object name as a variable that can be referenced externally. By establishing the name defined here as an external reference variable and using it in a user program, it is possible to code programs without being aware of object ID numbers. When an ID number is referenced, the use of this object name is recommended in coding. Number of fixed-size memorypool blocks/block size Assuming m as the size of one block in the fixed-size memorypool, n as the number of blocks, and M as the total size of the fixed-size memorypool, then M = m x n. (See Figure ) However, m must be a multiple of four bytes. The minimum value is 20 bytes. Overall fixed-size memorypool Block 1 Area of m bytes Block 2 Area of M = m x n bytes Block n Example of fixed-size memorypool with block size m and number of blocks n Figure Vanable-size MemoryPool Total Size/Number of Blocks The fixed-size memorypool area is automatically allocated from the area specified by the KNL_RAM definition statement. 34
53 2.4 Configuration Data (FR Family) Fixed-size memorypool ID Object IDs are used to identify individual objects. Note that ID numbers must be consecutive. The range of numbers that can be specified for IDs is 1 to If this specification is omitted, an available ID is automatically assigned. ID number Example of correct usage: Example of incorrect usage: ID is being used ID is not being used The example of incorrect usage generates an error because ID number 3 is not being used. Extended information Any 32-bit information that the user can use can be specified by a numeric value or a label. This information can be referenced by system call ref_mpf. 35
54 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Vector Definition (FR) The vector definition defines the following three items: Vector number Entry Reset vector entry Vector Definition Vector number Specify the vector number of the EIT vector being defined. The selectable vector numbers range from 16 to 62 and from 65 to 255. Entry Specify the label or address for the EIT vector entry. Reset vector entry Specify the entry name of the reset vector. If this specification is omitted, the reset vector name is _sys_entry. 36
55 2.5 Configuration Date (F²MC-16 Family) 2.5 Configuration Date (F²MC-16 Family) The configurator configures systems based on configuration data input from configuration files. This section explains the rules for defining configuration data in the F 2 MC-16 family, along with precautionary information and restrictions. Configuration data There are eleven types of configuration data definitions in the F 2 MC-16 family: CPU definition Linkage definition System definition Memory definition Task definition Common stack definition Semaphore definition Eventflag definition Mailbox definition Fixed-size memorypool definition Vector definition For the details of each definition, see Sections 2.5.1, CPU Definition, to , Vector Definition. 37
56 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR CPU Definition (F²MC-16) The CPU definition specifies the target CPU using its MB number. CPU definition Specify the target CPU of the program that performs configuration using its MB number. An error occurs if a CPU that cannot be selected is specified. 38
57 2.5.2 Linkage Definition (F²MC-16) 2.5 Configuration Date (F²MC-16 Family) Linkage definitions define the following four items. Relocatable object names Library names Absolute object names Map file output designations Linkage Definition Relocatable object names Relocatable object names designate user-relocatable objects. When designating file names, either relative paths or absolute paths may be used. Programs that reserve areas for tasks, memorypools, semaphores, eventflags or vector tables are automatically generated and embedded into execute files, and therefore need not be created. Library names Library names designate libraries for use in user programs. When designating file names, either relative paths or absolute paths may be used. Absolute object names Absolute object names designate absolute objects output from Configurator. When designating file names, either relative paths or absolute paths may be used. Map file output designations Map file output designations refer to the output of map files, which are files in which the absolute object name extension has been changed to.mp1 For example, the map file name corresponding to the absolute object name realos.abs would be realos.mp1. The map file can be used to check the list of options that have been sent to the linker by the configurator and the list of sections that have been allocated. 39
58 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR System Definitions (F²MC-16) F 2 MC-16 system definitions include definitions of the following 12 items: Number of cyclic activation handlers Number of alarm handlers Priority level CPU exception handler entry definition System call exception handling definition Include file name Kernel operation interrupt level Number of register banks F 2 MC-16F dedicated code selection wai_tsk embedding System clock handler return method Context register System Definitions Number of cyclic activation handlers and number of alarm handlers Specify the number of cyclic activation handlers and alarm handlers to be used by the user. Because the amount of memory used increases as this number increases, specify only the required number. (The amount of memory used for the cyclic activation handlers and alarm handlers is listed below.) The allowable range is 0 to 127. If this specification is omitted, the default is 0. Because these definition statements involve the use of timers, extra memory is required for timer operation. Object name Required memory Timer 4 Cyclic activation handler ( bit) x number of handlers Priority level Specify the lowest priority level assigned to a task to be used in the user system. The allowable range is 1 to 16. If this specification is omitted, the default is 16. Since a smaller priority level number requires more memory, use a priority level that is appropriate for the system. CPU exception handler entry definition Specify the entry of the CPU exception handler. If this specification is omitted, an CPU exception handler definition is not embedded. System call exception handling definition Specify the entry of the system call exception handler. If this specification is omitted, the system call exception handler definition is not embedded. You can also specify whether to trigger a system call exception for every error. Include file name Alarm handler x number of handlers (unit: bytes) Specify the name of the configuration file to be included. Include file nesting is not allowed. 40
59 2.5 Configuration Date (F²MC-16 Family) Kernel operation interrupt level Specify the kernel operation interrupt enable level. Specify an interrupt level that is lower than that used in applications. The allowable range is 0 to 6. Normally, 6 is used. If this specification is omitted, the default is 6. Number of register banks Reserve a specified number of register banks, starting with bank 0. The allowable range is 0 to 31. If this specification is omitted, the default is 31. This setting specifies how much of the RAM area for register banks is actually used for register banks. Automatic allocation is not performed by the linker for the area reserved by this setting. 16 x (1 + specified number) bytes of memory is required. F 2 MC-16F dedicated code selection Specify output of F 2 MC-16F dedicated code when an F 2 MC-16F family CPU is used. wai_tsk embedding Specify whether to embed the wai_tsk system call function. When wai_tsk is to be embedded, the system clock handler return method must be defined. System clock handler return method Specify the interface for the user-specified interrupt handler for the system clock. If this specification is omitted, a system clock interrupt handler is not embedded. Context register Specify whether to perform context switching by register bank switching or by saving the context to and restoring it from the stack. For context switching by saving the context to and restoring it from the stack, specify the memory register handled as the context. (Select all memory registers if you select context switching by saving the context to and restoring it from the stack using the C compiler.) When switching from one task to another, the kernel saves the PS, PC, PCB, DTB, ADB, DPR, A, and T registers. Note that the memory register to be saved is only the one specified here. When context switching by register bank switching is selected, the kernel does not save any memory registers. However, register bank switching has the same effect as saving all memory registers (RW0 to RW7). Note that a single register bank cannot be shared by multiple tasks (excluding stack-sharing tasks). 41
60 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Memory Definitions (F²MC-16) Memory definitions include definitions of the following three items: System stack Memory type and range Section name/address Memory Definitions System stack The system stack is used by the kernel and interrupt handlers. As the size, specify an even number from 0x20 to 0xfffe. If this specification is omitted, the default size is 256 bytes. Memory type and range Specify the ROM and RAM areas that can be allocated by the target. Automatic allocation is performed by the linker according to this setting. Kernel code (including data such as initial values) is placed at consecutive addresses that have been defined as kernel code addresses. Data managed by the system (such as operating system data and memorypools) is placed at consecutive addresses that have been defined as kernel data addresses. If kernel code addresses and kernel data addresses are not defined, code and data are automatically placed according to the specification of the ROM and RAM areas. Use an even-numbered address as the start address. Section name/address Specify the names of all sections used in user programs, as well as the addresses where those sections are to be placed. If addresses are omitted, sections are placed after the previously specified sections. When you specify sections for the first time, however, their addresses must also be specified. Note that definition of nonexistent sections will result in a linker error. Reference: For an explanation of kernel data addresses, see Appendix B, Allocating Kernel Code and Kernel Data. 42
61 MEMO 43
62 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Task Definitions (F²MC-16) Task definitions include definitions of the following 10 items: Task name Task ID Task entry Task start priority level Task stack size RP register Data bank register Additional data bank register Direct page register Condition code register Task Definitions Task name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Task ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 255. If this specification is omitted, unused IDs are automatically assigned. ID number Proper use Improper use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. Task entry Specify the entry of a task using a label or address. 44
63 2.5 Configuration Date (F²MC-16 Family) Task start priority level Specify the priority level for starting a task. Specify a priority level that is higher than the lowest priority level. If this specification is omitted, the lowest priority level is assigned. Task priority Task 1 Start priority level Lowest priority level 16 High Priority level Low Values in this range may be used for priority level settings. Task stack size Specify the size of the stack area used for a target task. If this specification is omitted, the default is a size of 0x100 bytes. If labels are defined for stack sharing, any task name or entry name that duplicates a label will result in an error. If C language functions are used to describe a user stack, the approximate stack size can be calculated using Softune C Analyzer. Note that the specified stack size must include the task context size. For an explanation of common stacks, see Section 2.5.6, Common Stack Definitions. RP register Specify the RP register used for a task. The allowable range is 0 to 31. However, do not specify bank 1 since it is used by the kernel. If this specification is omitted, register bank 0 is used for the task. If register bank switching is specified for the context register setting in the system definition, set different values for individual tasks (excluding stack-sharing tasks). Data bank register Specify data bank registers. The allowable range is 0x00 to 0xff. The default is 0. Additional data bank register Specify additional data bank registers. The allowable range is 0x00 to 0xff. The default is 0. Direct page register Specify direct page registers. The allowable range is 0x00 to 0xff. The default is 0x00. Condition code register Specify condition code registers. The allowable range is 0x00 to 0xff. The default is 0x40. (This default value is used unless there is a special case.) 45
64 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Common Stack Definitions (F²MC-16) Common stack definitions define stacks shared by multiple tasks. Common Stack Definitions Specifying a common stack allows multiple tasks to use the same stack. To create a common stack, specify the name and size of the stack. To allow a task to use a common stack, specify the common stack name instead of a task stack size. Specify a size of 0x0E to 0xFFFE bytes. If this specification is omitted, the default is 256 bytes. If multiple tasks using the same common stack enter any mode other than DORMANT mode (such as READY or WAIT), the target system may not operate properly. Tasks that operate at the same time must use different common stacks, or must avoid using any common stacks. [Sample of proper operation] [Sample of improper operation] Task A READY Task B DORMANT Task A READY Task B WAIT In use Not in use In use In use Common stack I Common stack I 46
65 2.5 Configuration Date (F²MC-16 Family) Semaphore Definitions (F²MC-16) Semaphore definitions include definitions of the following four items: Semaphore initial count (general) Semaphore initial count (individual) Semaphore name Semaphore ID Semaphore Definitions Semaphore initial count (general) Define the fixed value of the semaphore initial count for all semaphore IDs. The allowable range for the initial count value is 0 to 255. Semaphore initial count (individual) Specify a semaphore count at system startup in the range from 0 to 255. If this specification is omitted, the default is 1. This setting is ignored when a fixed value has been defined for the semaphore initial count. Semaphore name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Semaphore ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Improper use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 47
66 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Eventflag Definitions (F²MC-16) Eventflag definitions include definitions of the following five items: Eventflag control method Eventflag initial pattern (fixed value) Eventflag initial pattern Eventflag name Eventflag ID Eventflag Definitions Eventflag control method Specify the eventflag control method. Either 1-bit or 16-bit control can be selected. Eventflag initial pattern (fixed value) Define the fixed value of the eventflag initial pattern in the bit width selected for the eventflag control method. Before this setting can be defined, the eventflag control method must have already been defined. When selecting 1-bit eventflag control, specify 0 or 1. When selecting 16-bit eventflag control, specify a value in the range from 0 to 0xffff. Eventflag initial pattern Define an eventflag initial pattern at system startup in the bit width selected for the eventflag control method. When selecting 1-bit eventflag control, specify 0 or 1. When selecting 16-bit eventflag control, specify a value in the range from 0 to 0xffff. The default is 0. Specifying an initial pattern in any bit width other than that of the selected eventflag control method will result in an error. This setting is ignored when a fixed value has been defined for the eventflag initial pattern. Eventflag name Assign each object name an object ID number as a variable to which an external reference can be made. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. For references to ID numbers in coding, using object names is recommended. Eventflag ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. 48
67 2.5 Configuration Date (F²MC-16 Family) ID number Correct use Improper use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 49
68 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Mailbox Definitions (F²MC-16) Mailbox definitions include definitions of the following two items: Mailbox name Mailbox ID Mailbox Definitions Mailbox name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Mailbox ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Improper use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 50
69 MEMO 51
70 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Fixed-size MemoryPool Definitions (F²MC-16) Fixed-size memorypool definitions include definitions of the following three items: Fixed-size memorypool name Fixed-size memorypool ID Fixed-size memorypool size/block size Fixed-size memorypool Definitions Fixed-size memorypool name Assign each object name an object ID number as a variable to which an external reference can be made. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. For references to ID numbers in coding, using object names is recommended. Fixed-size memorypool ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Improper use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 52
71 2.5 Configuration Date (F²MC-16 Family) Fixed-size memorypool size/block size If the size of each block in a Fixed-size memorypool is m, the block count is n, and the total memorypool size for each ID is M, then M = m x n (see Figure ). Define the total size (M) of a Fixed-size memorypool for each ID that does not exceed 64K bytes. Total memorypool Block 1 m-byte area Block 2 M-byte area (M = m x n) Block n Example of Fixed-size memorypool with block size m and block count n Figure Total size of Fixed-size memorypool/block size In addition to the Fixed-size memorypool area, a Fixed-size memory block management area is required. The Fixed-size memorypool area and fixed size memory block management area are automatically allocated to the areas specified by the KNL_RAM definition statement. 53
72 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Vector Definitions (F²MC-16) Vector definitions include definitions of the following three items: Initialization handler entry Interrupt handler entry Reset vector entry Vector Definitions Initialization handler entry Define the entry of the initialization handler called when the operating system starts. The default name for the initialization handler is _inihdr. Interrupt handler entry Specify a label name or address as the entry name of the interrupt handler. Specify the interrupt number as an IRQn number. Specify a value in the range from 11 to 41 as the interrupt number. Reset vector entry Specify the entry name of the reset vector. The default name of the reset vector is _sys_entry. 54
73 2.6 Configuration Data (F²MC-8L Family) 2.6 Configuration Data (F²MC-8L Family) The configurator configures systems based on configuration data, which is input from configuration files. This section describes the rules for defining configuration data for the F 2 MC-8L family as well as provides precautionary information and limitations. Definitions of Configuration Data There are ten types of configuration data definitions. CPU definition Linkage definition System definition Memory definition Task definition Common stack definition Semaphore definition Eventflag definition Mailbox definition Vector definition Section 2.6.1, CPU Definition, to Section , Vector Definition, describe each definition. 55
74 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR CPU Definition (F²MC-8L) The CPU definition specifies the target CPU using its MB number. CPU Definition Specify the target CPU of the program that performs configuration using an MB number. Specifying a CPU that cannot be selected causes an error. 56
75 2.6.2 Linkage Definition (F²MC-8L) 2.6 Configuration Data (F²MC-8L Family) The linkage definitions include definitions of the following four items: Relocatable object names Library names Absolute object names Map file output Linkage Definitions Relocatable object names Specify as a relocatable object name the name of a user-relocatable object. Either the absolute path or a relative path can be used to specify a file name. Library names Specify as a library name the name of a library to be used by the user program. Either the absolute path or a relative path can be used to specify a file name. Absolute object names Specify the names of absolute objects to be output when configuration is performed. Map file output Specify whether to output a map file. The map file, which is the absolute object name with its extension changed to.mp1, is output to the current directory. For example, the map file name corresponding to the absolute object name realos.abs would be realos.mp1. The map file can be used to check the list of options that have been sent to the linker by the configurator and the list of sections that have been allocated. 57
76 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR System Definitions (F²MC-8L) F 2 MC-8L system definitions include definitions of the following seven items: Number of cyclic activation handlers Exception processing embedding Priority level Include file Method for returning from system clock handler Number of register banks wai_tsk embedding System Definitions Number of cyclic activation handlers Specify the number of cyclic activation handlers to be used by the user. Because the amount of memory used increases as this number increases, specify only the required number. The amount of memory used for the cyclic activation handlers is listed below. Because these definition statements involves the use of timers, also take into consideration the extra memory required for the timers. The allowable range is 0 to 127. If this specification is omitted, the default is 0. Object name Amount of memory used Exception processing embedding Specify whether to embed exception processing in the kernel. If a name for exception processing is specified, the exception handler is called when a system call execution error occurs. Otherwise, an exception handler is not called. If an exception handler is embedded, the following error handing routines are installed: Reserved function error Parameter error Illegal object definition Context error Run-time error Forcible wait state cancellation Results of processing Priority level Timer 4 Cyclic activation handler (8 bytes + 1 bit) x number of handlers (unit: bytes) Seven and fewer bits are rounded up. Specify the lowest priority level to be used by the user system. The allowable range is 1 to 4. If this specification is omitted, the default is 4. Since a smaller priority level number requires more memory, use a priority level that is appropriate for the system. 58
77 2.6 Configuration Data (F²MC-8L Family) Include file Specify the names of the configuration files that are to be included. Include files cannot be nested. System clock handler return method Specify the interface for the system clock interrupt handler specified by the user. If this definition is omitted, interrupt handling is terminated by the ret instruction. Number of register banks Reserve a specified number of register banks, starting with bank 0. The allowable range is 0 to 31. If this specification is omitted, the default is 31. Since this definition specifies the size of the RAM area to be used for register banks, automatic allocation is not performed by the linker for the area reserved by this setting. The amount of memory required is 8 x (1 + specified number) (unit: bytes). wai_tsk embedding Specify whether to embed the wai_tsk system call function. If embedding of wai_tsk is specified, also define the system clock handler return method. 59
78 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Memory Definitions (F²MC-8L) Memory definitions include definitions of the following three items: System stack Memory type and area Section name/address Memory Definitions System stack The system stack is used by the kernel and interrupt handlers. The allowable range is 0x20 to 0x2000. If this specification is omitted, the default is 40 bytes. Memory type and area Specify ROM and RAM areas that can be allocated by the target. Automatic allocation is performed by the linker according to this setting. Kernel code (including data such as initial values) is placed at consecutive addresses that have been defined as kernel code addresses. Data managed by the system, such as operating system data and memorypools, is placed at consecutive addresses that have been defined as kernel data addresses. If kernel code addresses or kernel data addresses are not defined, code and data are automatically placed according to the specification of the ROM and RAM areas. Specify an even-numbered address as the start address. Section name/address Specify as section names the names of all sections used by the user program. Specify as addresses the addresses at which those sections are to be placed. If the address corresponding to a section is not specified, the section is placed immediately after the section specified last. Accordingly, the address for the first specified section must be specified. Note that definition of nonexistent sections will result in a linker error. Reference: For an explanation of kernel data addresses, see Appendix B, Allocating Kernel Code and Kernel Data. 60
79 MEMO 61
80 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Task Definitions (F²MC-8L) Task definitions include definitions of the following six items: Task name Task ID Task entry Task start priority level Task stack size RP registers Task Definitions Task name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Task ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 255. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Incorrect use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. Task entry Specify the entry of a task using a label or address. 62
81 2.6 Configuration Data (F²MC-8L Family) Task start priority level Specify the priority level for starting a task. Specify a priority level that is higher than the lowest priority level in the system definition. If this specification is omitted, the lowest priority level is assigned. Task Task priority level 1 Start priority level Lowest priority level Values in this range may be used for priority level settings. High Priority level Low Task stack size Specify the size of the stack or the name of the common stack used by a task. The allowable range is 0x000E to 0x2000. If this specification is omitted, the default is 40 bytes. If C language functions are used to describe a user stack, the approximate stack size can be calculated using Softune C Analyzer. If this is done, take into consideration the stack to be used as the task context. For an explanation of common stacks, see Section 2.6.6, Common Stack Definition. RP register Specify the registers to be used by a task. The allowable range is 1 to 31. However, do not specify bank 0 since it is used by the kernel. If this specification is omitted, the default is 1. 63
82 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Common Stack Definitions (F²MC-8L) Common stack definitions define stacks used shared by multiple tasks. Common Stack Definitions Specifying a common stack allows multiple tasks to use the same stack. To create a common stack, specify the name and size of the stack. To allow a task to use a common stack, specify the common stack name instead of a task stack size. Specify a value between 0x0E and 0x2000 bytes for the common stack size. If this specification is omitted, the default is 40 bytes. If multiple tasks using the same common stack enter any mode other than DORMANT mode (such as READY or WAIT mode), the target system may not operate properly. Tasks that operate at the same time must use different common stacks, or must avoid using any common stacks. [Example of proper operation] [Example of improper operation] Task A READY Task B DORMANT Task A READY Task B WAIT Using Not using Using Using Common stack I Common stack I 64
83 2.6 Configuration Data (F²MC-8L Family) Semaphore Definitions (F²MC-8L) The Semaphore definitions include definitions of the following four items: Semaphore initial count (general) Semaphore initial count (individual) Semaphore name Semaphore ID Semaphore Definitions Semaphore initial count (general) Specify the semaphore initial count value only when the same fixed value is specified for all semaphore IDs. The allowable range is 0 to 255. Semaphore initial count (individual) Specify a value between 0 and 255 for the semaphore count value at system startup. If this specification is omitted, the default is 1. This setting is ignored when a semaphore initial count value has been specified. Semaphore name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Semaphore ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Incorrect use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 65
84 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Eventflag Definitions (F²MC-8L) Eventflag definitions include definitions of the following two items: Eventflag name Eventflag ID Eventflag Definitions Eventflag name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Eventflag ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Incorrect use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 66
85 2.6 Configuration Data (F²MC-8L Family) Mailbox Definitions (F²MC-8L) The mailbox definitions include definitions of the following two items: Mailbox name Mailbox ID Mailbox Definitions Mailbox name Assign each object name an object ID number so that it can be handled as an external reference variable. In user programs, the use of defined names as external reference variables enables programs to be coded without having to consider object ID numbers. Fujitsu recommends using these object names when referencing ID numbers. Mailbox ID Object IDs are used to identify individual objects. Note that ID numbers must be assigned sequentially. Assign IDs in the range from 1 to 127. If this specification is omitted, unused IDs are automatically assigned. ID number Correct use Incorrect use : ID number used : ID number not used In the incorrect use example, an error will result because ID number 3 is not used. 67
86 CHAPTER 2 OVERVIEW OF THE CONFIGURATOR Vector Definitions (F²MC-8L) Vector definitions include definitions of the following four items: Initialization handler entry Call vector entry Interrupt handler entry Reset vector entry Vector Definitions Initialization handler entry Define the entry name of the initialization handler called when the operating system starts. The default name for the initialization handler is _inihdr. Call vector entry Specify the entry name and vector number of the call vector. Specify a value in the range from 2 to 7. Interrupt handler entry Specify a label name or address as the entry name of the interrupt handler. Specify the interrupt number as an IRQn number. Specify a value in the range from 0 to 11 as the interrupt number. Reset vector entry Specify the entry name of the reset vector. The default name of the reset vector is _sys_entry. 68
87 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS This chapter describes the structure of and lists the configuration definition statements and explains them in detail. 3.1 Overview of the Configuration Definition Statements 3.2 Definition Statement Explanation 69
88 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS 3.1 Overview of the Configuration Definition Statements Configuration definition statements are the data formats used when the configurator stores configuration data in configuration files. Overview of the Configuration Definition Statements Configuration definition statements consist of the configuration definition name and parameters. Tables 3.1a, 3.1b and 3.1c list the configuration definition names. Table 3.1a List of Configuration Definition Names [FR] Configuration data name Definition name Description of definition CPU definition CPU CPU type Linkage definition RELOCATE_FILE Relocatable object name LIBRARY_FILE ABSOLUTE_FILE MAP_FILE Library file name Absolute object name Map file output specification System definition CYC_HDR_NUMBER Number of cyclic activation handlers ALM_HDR_NUMBER EXC_HDR_ENTRY PRIORITY_LEVEL INCLUDE Number of alarm handlers Exception handler entry Priority level INCLUDE file name Memory definition SYS_STK_SIZE System stack size ROM RAM KNL_ROM KNL_RAM USR_SECTION Code address range area name Data address range area name Kernel code allocation address Kernel data allocation address Section name and section location System call definition SYSTEM_CALL Embedded system call Task definition TSK Task definition COM_STACK Task common stack definition Semaphore definition SEM Semaphore definition Eventflag definition FLG Eventflag definition Mailbox definition MBX Mailbox definition Memorypool definition MPL Variable-size memorypool definition MPF Fixed-size memorypool definition Vector definition EIT_ENTRY Vector definition MPF Fixed-size memorypool definition 70
89 3.1 Overview of the Configuration Definition Statements Table 3.6b List of Configuration Definition Names [16] Configuration data name Definition name Description of definition Vector definition EIT_ENTRY Vector definition RESET_ENTRY Reset vector entry CPU definition CPU CPU type Linkage definition RELOCATE_FILE Relocatable object name LIBRARY_FILE ABSOLUTE_FILE MAP_FILE Library file name Absolute object name Map file output specification System definition CYC_HDR_NUMBER Number of cyclic activation handlers ALM_HDR_NUMBER CPU_EXTHDR_ENTRY SYS_EXTHDR_ENTRY PRIORITY_LEVEL INCLUDE ILM CODE SYS_CLOCK CONTEXT_REGISTER REGISTER_BANK wai_tsk Number of alarm handlers CPU exception handler entry System call exception handler entry Priority level INCLUDE file Interrupt level at kernel operation F 2 MC-16F code output selection System clock handler return method Context register Number of register banks wai_tsk installation Memory definition SYS_STK_SIZE System stack size ROM RAM KNL_ROM KNL_RAM USR_SECTION Code address range Data address range Kernel code location address Kernel data location address Section name and section location address Task definition TSK Task definition COM_STACK Task common stack specification Semaphore definition SEM_ICNT Semaphore initial count value definition SEM Semaphore definition 71
90 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Table 3.6b List of Configuration Definition Names [16] (Continued) Configuration data name Definition name Description of definition Eventflag definition FLG_BIT Selection of eventflag management method FLG_PATTERN FLG Setting of eventflag initial pattern value Eventflag definition Mailbox definition MBX Mailbox definition Memorypool definition MPL Memorypool definition Vector definition EIT_ENTRY Interrupt handler entry INIT_HDR_ENTRY RESET_ENTRY Initialization handler entry Reset vector entry 72
91 3.1 Overview of the Configuration Definition Statements Table 3.1c List of Configuration Definition Names [8L] Configuration data name Definition name Description of definition CPU definition CPU CPU type Linkage definition RELOCATE_FILE Relocatable object name LIBRARY_FILE ABSOLUTE_FILE MAP_FILE Library file name Absolute object name Map file output specification System definition CYC_HDR_NUMBER Number of cyclic activation handlers SCAL_EXC_ENTRY PRIORITY_LEVEL INCLUDE SYS_CLOCK REGIGTER_BANK wai_tsk System call optimization/exception handler name Priority level INCLUDE file System clock handler return method Number of register banks wai_tsk installation Memory definition SYS_STK_SIZE System stack size ROM RAM KNL_ROM KNL_RAM USR_SECTION Code address size area name Data address size area name Kernel code allocation address Kernel data allocation address Section name and section location address Task definition TSK Task definition COM_STACK Task common stack specification Semaphore definition SEM_ICNT Semaphore initial count value definition SEM Semaphore definition Eventflag definition FLG Eventflag definition Mailbox definition MBX Mailbox definition Vector definition EIT_ENTRY Interrupt handler entry CALL_ENTRY INIT_HDR_ENTRY RESET_ENTRY Call vector entry Initialization handler entry Reset vector entry 73
92 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS 3.2 Definition Statement Explanation This section provides details on the definition statement formats. Definition Statement Formats Definition Name [FR] definition-name parameter-1, parameter-2,..., parameter-n [Optional: ] [16] definition-name parameter-1, parameter-2,..., parameter-n [Optional: ] [8L] definition-name parameter-1, parameter-2,..., parameter-n [Optional: ] Definition Name [Explanation] This section provides a description of the definition statement, including how to specify the parameters, the ranges of values that can be specified, and the keywords that can be selected. [Example] This section provides examples of how the definition statement is described in a file. Refer to these examples when describing the definition statement in a configuration file. Configuration file definition-name parameter-list Reading the Definition Statements 74 If a given definition statement is Nonomissible, that definition statement must always be specified at least once. If a definition statement is Omissible, the default value for that statement is assumed to have been specified. The definition name can be described in either upper-case or lower-case letters. Only one definition statement can be specified on one line, and lines cannot be continued.
93 3.2 Definition Statement Explanation Any characters that follow a # symbol in a definition statement are regarded as comments. The definition name and the parameters can be separated by any number of spaces or tab characters. (The symbol represents any number of spaces or tab characters.) Parameters are delimited by commas (, ). Spaces or tab characters before and after these commas are ignored. [Example] TSK tsk_1, tsk_1_entry,,0x1000,ready,3,,0xffffffff Parameters that are enclosed in square brackets ( [ and ] ) may be omitted. [Example] When defining a common stack, the following three specifications have the same meaning: COM_STACK name COM_STACK name, COM_STACK name,1024 Parameters that are enclosed in rounded brackets ( { and } ) indicate that one of the elements enclosed in the brackets is to be selected. The vertical bar ( ) is used to delimit the elements in the list of choices. (The selected element can be described in either upper- or lower-case letters.) [Example] MAP_FILE {LIST NOLIST} Parameters that begin with 0x are regarded to be values specified in hexadecimal notation. Parameters that begin with 0 are regarded to be values specified in octal notation. Parameters that begin with other values are regarded to be specified in decimal notation. (For example, 0400, 256, and 0x100 all represent the decimal value 256.) If an address, value, etc., that exceeds 32 bits is specified, only the least significant 32 bits are valid. (For example, the value 0x is regarded as 0x1234.) If an external reference symbol, such as an entry, contains a character that cannot be used with the assembler/linker, an error is generated by the assembler/linker. The following types of characters can be used in external reference symbols: - Letters - Numbers - Underscores ( _ ) Note:However, the first character cannot be a number. 75
94 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS CPU [FR] CPU cpu [Optional: ] [16] CPU cpu [, [mode] [, [bus] [, [multi] [, [exec_ram]]]]] [Optional: ] [8L] CPU cpu [, [mode]] [Optional: ] CPU [Explanation] Specify the target CPU by inputting an MB number. An error occurs if an unavailable parameter is designated or if this definition statement is used to define a duplicate target CPU. [Example] Specifying MB91V100 as the target CPU: Configuration file CPU MB91V100 CPU [16] [Explanation] This definition statement defines the mode register at CPU address 0xFFFFDF. cpu: mode: bus: multi: exec_ram: This parameter specifies the target CPU series name as an MB number (MB90700/MB90750H/MB90220/MB ). This parameter selects the microcomputer chip mode from single, internal ROM, and external ROM (SINGLE/IN_ROM/OUT_ROM). This parameter selects the bus mode from 8-bit and 16-bit (8 bit/16 bit/no setting). This parameter selects whether the bus is a multiplex bus (MULTI/NOMULTI/ no setting). This parameter selects whether the built-in RAM program is used (EXEC_RAM/RAM/no setting). Omit parameters that are not related to the target CPU. An error occurs if any parameter that cannot be selected is specified or a target CPU is defined twice. No definition statement can be omitted. 76
95 3.2 Definition Statement Explanation [Example] Setting an MB90550 CPU: CPU series name : MB90550 Chip mode : External ROM Bus mode : 16 bits Multiplex bus : Omitted Built-in RAM : Omitted Configuration file CPU MB90550,OUT_ROM Setting an MB90753H CPU: CPU series name : MB90750H Chip mode : Internal ROM Bus mode : 8 bits Multiplex bus : NOMULTI Built-in RAM : Omitted Configuration file CPU MB90750H,IN_ROM,8BIT,NOMULTI 77
96 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Setting an MB90223 CPU: CPU series name : MB90220 Chip mode : External ROM Bus mode : 16 bits Multiplex bus : Omitted Built-in RAM : Usable Configuration file CPU MB90220,OUT_ROM,16BIT,,EXEC_RAM Setting an MB90678 CPU: CPU series name : MB90675 Chip mode : Single Bus mode : 8 bits Multiplex bus : Omitted Built-in RAM : Omitted Configuration file CPU MB90675,SINGLE,8BIT In addition to the above settings, settings for each series are possible. CPU [8L] [Explanation] This definition statement defines the reset mode at CPU address 0xFFFD. cpu: mode: This parameter specifies the target CPU series name using an MB number (MB89120/MB89620/MB89820/MB ). This parameter selects the microcomputer chip mode from single chip mode and external bus allowable mode (SINGLE/BUS/no setting). An error occurs if any parameter that cannot be selected is specified or a target CPU is defined twice. 78
97 3.2 Definition Statement Explanation [Example] Setting an MB89144 CPU: CPU series name : MB89140 Chip mode : Single Configuration file CPU MB89140,SINGLE Setting an MB89629R CPU: CPU series name : MB89620R Chip mode : External bus allowable mode Configuration file CPU MB89620R,BUS Setting an MB89875 CPU: CPU series name : MB89870 Chip mode : Omitted (single) Configuration file CPU MB
98 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS RELOCATE_FILE [FR] RELOCATE_FILE filename [Optional: ] [16] RELOCATE_FILE filename [Optional: ] [8L] RELOCATE_FILE filename [Optional: ] RELOCATE_FILE [Explanation] This definition statement specifies the name of a user relocatable object to be linked to the system during the linking process. The specified file name cannot include a comma (, ), however. This definition statement can be defined as many times as necessary. [Example] Linking the relocatable objects test1.obj and test2.obj : Configuration file RELOCATE_FILE test1.obj RELOCATE_FILE test2.obj 80
99 3.2.3 LIBRARY_FILE 3.2 Definition Statement Explanation [FR] LIBRARY_FILE filename [Optional: ] [16] LIBRARY_FILE filename [Optional: ] [8L] LIBRARY_FILE filename [Optional: ] LIBRARY_FILE [Explanation] This definition statement specifies the name of a user library to be linked to the system during the linking process. The specified file name cannot include a comma (, ), however. This definition statement can be defined as many times as necessary. If this definition statement is omitted, no libraries are linked. [Example] Linking the libraries realos.lib and userlib.lib : Configuration file LIBRARY_FILE realos.lib 81
100 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS ABSOLUTE_FILE [FR] ABSOLUTE_FILE filename [Optional: ] [16] ABSOLUTE_FILE filename [Optional: ] [8L] ABSOLUTE_FILE filename [Optional: ] ABSOLUTE_FILE [Explanation] This definition statement specifies the name of the absolute object to be output during the linking process. If this definition statement is used twice to define an absolute object name, the definition that appears last is valid. If this definition statement is omitted, realos.abs is used for the name of the absolute object that is output. [Example] Specifying realos01.abs as the name of the absolute object to be output during the linking process: Configuration file ABSOLUTE_FILE realos01.abs 82
101 3.2.5 MAP_FILE 3.2 Definition Statement Explanation [FR] MAP_FILE {LIST I NOLIST} [Optional: ] [16] MAP_FILE {LIST I NOLIST} [Optional: ] [8L] MAP_FILE {LIST I NOLIST} [Optional: ] MAP_FILE [Explanation] This definition statement specifies whether the Linker should output a map file. LIST: The Linker outputs a map file. NOLIST: The Linker does not output a map file. If LIST is specified, the name of the map file that is output by the linker is the name of the absolute object with the extension changed to.mp1. If this definition statement is used twice to specify whether the linker should output a map file, the definition that appears last is valid. If this definition statement is omitted, a map file is output. The map file can be used to check the list of options that have been sent to the linker by the configurator and the list of sections that have been allocated. [Example] Outputting a map file: Configuration file MAP_FILE LIST Not outputting a map file: Configuration file MAP_FILE NOLIST 83
102 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS CYC_HDR_NUMBER [FR] CYC_HDR_NUMBER number [Optional: ] [16] CYC_HDR_NUMBER number [Optional: ] [8L] CYC_HDR_NUMBER number [Optional: ] CYC_HDR_NUMBER [Explanation] This statement defines the number of cyclic activation handlers used by the system. The number of cyclic activation handlers can be specified within the following ranges: [FR] 0 to [16] 0 to 127 [8L] 0 to 127 If this definition statement is used twice to define the number of cyclic handlers, the definition that appears last is valid. If this definition statement is omitted, the number of cyclic activation handlers is 0. When installing cyclic activation handlers for the FMC-16 and FMC-8L, define the system clock handler return method. For the amount of memory used in this definition, see Sections 2.4.3, 2.5.3, and 2.6.3, System Definition. [Example] Defining the number of cyclic activation handlers as 5 : Configuration file CYC_HDR_NUMBER 5 84
103 3.2.7 ALM_HDR_NUMBER 3.2 Definition Statement Explanation [FR] ALM_HDR_NUMBER number [Optional: ] [16] ALM_HDR_NUMBER number [Optional: ] [8L] [Optional: - ] ALM_HDR_NUMBER [Explanation] This definition statement defines the number of alarm handlers used by the system. The number of alarm handlers can be specified within the following ranges: [FR] 0 to [16] 0 to 127 If this definition statement is used twice to define the number of alarm handlers, the definition that appears last is valid. If this definition statement is omitted, the number of alarm handlers is 0. [Example] Defining the number of alarm handlers as 5 : Configuration file ALM_HDR_NUMBER 5 When installing alarm handlers, define the system clock handler return method. For the amount of memory used in this definition, see Sections 2.4.3, 2.5.3, and 2.6.3, System Definition. 85
104 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS EXC_HDR_ENTRY [FR] EXC_HDR_ENTRY entry [Optional: ] [16] [Optional: - ] [8L] [Optional: - ] EXC_HDR_ENTRY [Explanation] This definition statement defines, by means of a label or address, the entry for the exception handler that is called when a CPU exception or a system call exception (an error that occurs during execution of a system call) occurs. If this definition statement is used twice to define the exception handler, the definition that appears last is valid. If this definition statement is omitted, no exception handler is embedded. [Example] Defining the entry exc_entry for an exception handler: Configuration file EXC_HDR_ENTRY exc_entry Note: Exception handler It is necessary to define an exception handler in order to execute suitable exception processing and then continue normal processing if a CPU exception occurs in the target system. If a CPU exception is generated without an exception handler having been defined, the user s system down processing may be executed and the target system may not be able to continue with its processing correctly. 86
105 3.2.9 CPU_EXTHDR_ENTRY 3.2 Definition Statement Explanation [FR] [Optional: - ] [16] CPU_EXTHDR_ENTRY entry [Optional: ] [8L] [Optional: - ] CPU_EXTHDR_ENTRY [Explanation] Defines the name of the exception handler to be called when a CPU exception occurs. If more than one exception handler is defined using this definition statement, the last definition will be valid. If this definition statement is omitted, no CPU exception handler will be installed. [Example] To define the entry _cpu_exception as the CPU exception handler: Configuration file CPU_EXTHDR_ENTRY _cpu_exception 87
106 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SYS_EXTHDR_ENTRY [FR] [Optional: - ] [16] SYS_EXTHDR_ENTRY entry[, [ {1 I 2} ]] [Optional: ] [8L] [Optional: - ] SYS_EXTHDR_ENTRY [Explanation] Defines the name of the exception handler to be called when a system call exception occurs (when an error occurs during execution of a system call). Either the number 1 or 2 should be selected (if this statement is omitted, the default value 1 is designated). 1 Perform exception handling for all errors 2 Perform exception handling for all errors except for time-outs (E_TMOUT) and polling failures (E_PLFAIL). If more than one exception handler is defined using this definition statement, the last definition will be valid. If this definition statement is omitted, no exception handler will be installed. [Example] To define the entry _scall_exception as the system exception handler, with exception processing for all errors: Configuration file SYS_EXTHDR_ENTRY _scall_exception,1 To define the entry _scall_exception as the system exception handler, with exception processing for all errors except for time-outs (E_TMOUT) and polling failures (E_PLFAIL): Configuration file SYS_EXTHDR_ENTRY _scall_exception,2 88
107 MEMO 89
108 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SCAL_EXC_ENTRY [FR] [Optional: - ] [16] [Optional: - ] [8L] SCAL_EXC_ENTRY {NORMALIZE_2 I NORMALIZE_A [, [entry] ] I OPTIMIZE} [Optional: ] SCAL_EXC_ENTRY [Explanation] This definition statement defines the entry name of the exception handler that will be called if optimization processing and exception processing (for an error at system clock execution) for the ret_int system call occurs. NORMALIZE_2 : This parameter selects two-error processing. NORMALIZE_A: This parameter selects all-error processing. OPTIMIZE : This parameter selects optimization processing. Processing of the system call (ret_int) to be returned from the interrupt handler is optimized. Alternatively, whether to install kernel error processing is selected and whether to install exception processing is set. If optimization is specified, no error handling is performed. If NORMALIZE_A is selected, the all-error processing listed below is performed. If NORMALIZE_2 is selected, the two-error processing listed below is performed. If an entry name is set, it is used as the entry name of the exception handler that is called when exception processing occurs. NORMALIZE_A - Reserved function error class processing - Parameter error class processing - Context error processing - Incorrect object error class processing - Execution-time error class processing NORMALIZE_2 - Wait status forcible release error class processing - Processing execution result error class processing If this definition statement is used twice to define the exception handler name, the definition that appears last is valid. If this definition statement is omitted, NORMALIZE_2 error processing is performed. The system call exception handler will not be installed. 90
109 3.2 Definition Statement Explanation [Example] For optimization Configuration file SCAL_EXC_ENTRY OPTIMIZE Selecting all-error processing and defining entry name scall_exception for the system exception handler: Configuration file SCAL_EXC_ENTRY NORMALIZE_A, scall_exception Selecting all-error processing: Configuration file SCAL_EXC_ENTRY NORMALIZE_A Selecting two-error processing and defining entry name scall_exception for the system exception handler: Configuration file SCAL_EXC_ENTRY NORMALIZE_2, scall_exception Selecting two-error processing: Configuration file SCAL_EXC_ENTRY NORMALIZE_2 91
110 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS PRIORITY_LEVEL [FR] PRIORITY_LEVEL level [Optional: ] [16] PRIORITY_LEVEL level [Optional: ] [8L] PRIORITY_LEVEL level [Optional: ] PRIORITY_LEVEL [Explanation] This definition statement defines the task priority level. The task priority level can be specified within the following ranges: [FR] 8 to 32 [16] 1 to 16 [8L] 1 to 4 If this definition statement is used twice to define the task priority level, the definition that appears last is valid. If this definition statement is omitted, the priority level is as follows: [FR] 32 [16] 16 [8L] 4 Before task definition, set PRIORITY_LEVEL. [FR] 8 x task priority level [16] 2 x task priority level [8L] 4 x task priority level If the priority level decreases, the amount of memory used increases. Set an appropriate level. 92
111 3.2 Definition Statement Explanation [Example] Defining the priority level as 8 [example for FR] Configuration file PRIORITY_LEVEL 8 In this example, task priorities lower than task priority 8 (9 to 32) cannot be used. Therefore, a priority within the range specified by this priority level (1 to 8) must be specified when task startup priority in a task definition and the task priority in a program are changed. 93
112 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS INCLUDE [FR] INCLUDE filename [Optional: ] [16] INCLUDE filename [Optional: ] [8L] INCLUDE filename [Optional: ] INCLUDE [Explanation] This definition statement specifies an INCLUDE file in which data for a user module is defined. INCLUDE files cannot be nested. This definition statement can be defined as many times as necessary. If this definition statement is omitted, no INCLUDE files are loaded. [Example] Specifying that the INCLUDE file usrdef.rcf is to be loaded: Configuration file INCLUDE usrdef.rcf 94
113 ILM 3.2 Definition Statement Explanation [FR] [Optional: - ] [16] ILM number [Optional: ] [8L] [Optional: - ] ILM [Explanation] Defines allowable interrupt levels during kernel execution. This statement is used to define the scope of interrupts that are allowed during system calls issued by tasks. Handler interrupts levels for system calls issued by handlers remain unchanged, and are not affected by interrupt levels set using this statement. The allowable range of interrupt levels is 0 to 6. If more than one kernel operation interrupt level is defined using this definition statement, the last definition will be valid. If this definition statement is omitted, the interrupt level will be level 6. For most normal uses, interrupt level 6 is used. [Example] To set the kernel operation interrupt level to level 5 Configuration file ILM 6 95
114 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS CODE [FR] [Optional: - ] [16] CODE { 16F I 16L } [Optional: ] [8L] [Optional: - ] CODE [Explanation] Performs output definitions for F²MC-16F dedicated code This statement selects output file codes for the use of a 16F microcontroller core. 16F 16F dedicated code output 16L 16L/16LX/16/16H code output This setting has no significance unless a 16F microcontroller is used. If more than one definition is made using this definition statement, the last definition will be valid. If this definition statement is omitted, 16F code output will be selected. [Example] To designate 16L/16LX/16/16H microcontroller dedicated output code Configuration file CODE 16L 96
115 MEMO 97
116 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SYS_CLOCK [FR] [Optional: - ] [16] SYS_CLOCK {RET I RETP I ret_int} [Optional: ] [8L] SYS_CLOCK {RET I ret_int} [Optional: ] SYS_CLOCK [Explanation] This definition statement defines the system clock handler return method. RET RETP (16 only) ret_int If this definition statement is used twice to define the system clock handler, the definition that appears last is valid. If this definition statement is omitted, no system clock is installed for an FMC-16. For an FMC-8L, processing terminates with the ret instruction. Specify this setting according to the method of creating the system clock handler. For details, see the Softune REALOS Kernel Manual. Task User-generated processing Preprocessing a Postprocessing c Using REALOS System clock handler b Figure Status Transition of the System Clock Handler Table a Generating the System Clock Handler Return [16] System clock handler generation method Part a Part b Part c Preprocessing Postprocessing C language or assembly language Call ret Ret_int Yes Yes Callp retp Ret_int Yes Yes Assembly language jmp[p] ret_int Yes No 98
117 3.2 Definition Statement Explanation Table b Generating the System Clock Handler Return [8L] System clock handler generation method Part a Part b Part c Preprocessing Postprocessing Assembly language call Ret Ret_int Yes Yes jmp Retp_int Yes No C language Function call Ret Ret_int Yes Yes [Example] Designating RET as the system clock handler return method Configuration file SYS_CLOCK RET 99
118 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS CONTEXT_REGISTER [FR] [Optional: - ] [16] CONTEXT_REGISTER number [Optional: ] [8L] [Optional: - ] CONTEXT_REGISTER [Explanation] This definition statement defines from bit information the memory register used as the context. The context register can be specified within the range from 0 to 0xff => 0xff RW7 RW6 RW5 RW4 RW3 RW2 RW1 RW0 If 0 is defined, register bank switching is used for context switching. If any value other than 0 is specified, stack switching (context switching for general stack saving and recovery) is used for the specified register. If this statement is used twice to define the number of context registers, the definition that appears last is valid. If this definition statement is omitted, register bank switching is used. For the context register, see Sections 2.5.3, System Definition. [Example] Using memory register RW7 as the context Configuration file CONTEXT_REGISTER 0x80 Note:To describe a task using the C compiler, specify 0 or 0xff. 100
119 REGISTER_BANK 3.2 Definition Statement Explanation [FR] [Optional: - ] [16] REGISTER_BANK number [Optional: ] [8L] REGISTER_BANK number [Optional: ] REGISTER_BANK [Explanation] This definition statement defines the register bank to be used. Specify this definition statement so that it includes the entire register bank area specified in the task definition. An error occurs if the defined value is lower than the specified register bank. Specify the register bank as 0 to 31. For an F 2 MC-16, register bank 1 is used by the kernel and the register bank 1 area is automatically reserved during linking. Note that even if register bank 1 is specified in the configuration file, a user can use only register bank 0. For an F 2 MC-8L, register bank 0 is used by the kernel and the register bank 0 area is automatically reserved during linking. Specifying register bank 0 has the same effect as specifying register bank 1. Since this definition statement specifies 0 to n, banks cannot be specified individually. If this definition statement is omitted, register bank 31 is assumed. If this statement is used twice to define the register bank, the definition that appears last is valid. Amount of memory used [16] Amount of memory used [8L] 16 x (1 + number) bytes 8 x (1 + number) bytes [Example] Defining register banks Register banks 0 to 5 are used. (Used memory: 96 bytes for an F 2 MC-16, 48 bytes for an F 2 MC-8L) Configuration file REGISTER_BANK 5 101
120 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS wai_tsk [FR] [Optional: - ] [16] wai_tsk {ON I OFF} [Optional: ] [8L] wai_tsk {ON I OFF} [Optional: ] wai_tsk [Explanation] [Example] This definition statement defines a wai_tsk system call function. ON This parameter installs the wai_tsk system call function. OFF This parameter does not install the wai_tsk system call function. If this definition statement is used twice to define wai_tsk, the definition that appears last is valid. If this definition statement is omitted, the system call function is installed. To install wai_tsk, define the system clock handler return method. Installing wai_tsk Configuration file wai_tsk ON 102
121 SYS_STK_SIZE 3.2 Definition Statement Explanation [FR] SYS_STK_SIZE size [Optional: ] [16] SYS_STK_SIZE size [Optional: ] [8L] SYS_STK_SIZE size [Optional: ] SYS_STK_SIZE [Explanation] This definition statement defines the system stack size. The system stack size can be specified as a byte count in the following ranges: [FR] Multiple of four bytes. The minimum is 256 bytes. [16] Even value from 0x020 to 0xfffe [8L] Value from 0x0020 to 0x2000 If this definition statement is used twice to specify the system stack size, the definition that appears last is valid. If this definition statement is omitted, the byte counts are as follows: [FR] 1024 bytes [16] 256 bytes [8L] 40 bytes See Appendix B for the system stack calculation method. [Example] Defining the system stack size as 0x1000 bytes: Configuration file SYS_STK_SIZE 0x1000 Note: System stack size The system stack is used by the kernel and by the interrupt handler. Define the system stack size with plenty of space. If the system stack size is insufficient, the target system will not operate correctly. 103
122 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS ROM [FR] ROM top_address, bottom_address, territory_name [Optional: ] [16] ROM top_address, bottom_address, territory_name [Optional: ] [8L] ROM top_address, bottom_address, territory_name [Optional: ] ROM [Explanation] [Example] This definition statement defines the area that can be allocated by the target microcontroller. [FR] top_address : 0x to 0xfffffffc Address that is a multiple of four bottom_address : 0x to 0xffffffff + 1 Address that is a multiple of four [16] top_address : 0x to 0xfffffe Even number address bottom_address : 0x to 0xffffff + 1 Even number address [8L] top_address : 0x0000 to 0xfffc Even number address bottom_address : 0x0001 to 0xffff + 1 Even number address territory_name : Area name This definition statement can be specified two or more times. It cannot be omitted. Locating the ROM area at addresses 0x to 0x10faff and naming the area ROMarea Configuration file ROM 0x100000,0x10faff,ROMarea Locating the ROM area at addresses 0x to 0x107fff and at addresses 0xff3000 to 0xffffff Configuration file ROM ROM 0x100000,0x107fff,test 0xff3000,0xffffff,rom_test 104
123 RAM 3.2 Definition Statement Explanation [FR] RAM top_address, bottom_address,territory_name [Optional: ] [16] RAM top_address, bottom_address,territory_name [Optional: ] [8L] RAM top_address, bottom_address,territory_name [Optional: ] RAM [Explanation] [Example] This definition statement defines the area that can be located by the target microcontroller. [FR] top_address : 0x to 0xfffffffc Address that is a multiple of four bottom_address : 0x to 0xffffffff + 1 Address that is a multiple of four [16] top_address : 0x to 0xfffffe Even number address bottom_address : 0x to 0xffffff + 1 Even number address [8L] top_address : 0x0000 to 0xfffc Even number address bottom_address : 0x0001 to 0xffff + 1 Even number address territory_name : Area name This definition statement can be used two or more times. It cannot be omitted. Locating the RAM area at addresses 0x to 0x003fff and naming the area name RAMarea Configuration file RAM 0x000000,0x003fff,RAMarea Locating the RAM area at addresses 0x to 0x000fff and at addresses 0x to 0x02ffff Configuration file RAM RAM 0x000000,0x000fff,test 0x020000,0x02ffff,ram_test 105
124 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS KNL_ROM [FR] KNL_ROM address [Optional: ] [16] KNL_ROM address [Optional: ] [8L] KNL_ROM address [Optional: ] KNL_ROM [Explanation] This definition statement defines the address at which the kernel code is located. [FR] address: 0x to 0xfffffffc Address that is a multiple of four [16] address: 0x to 0xfffffe Even number address [8L] address: 0x0000 to 0xfffe Even number address If this definition statement is used twice to define the address where the kernel code is located, the definition that appears last is valid. This definition statement cannot be omitted. [Example] Locating the kernel code in addresses 0x000c0000 Configuration file KNL_ROM 0x000c
125 KNL_RAM 3.2 Definition Statement Explanation [FR] KNL_RAM address [Optional: ] [16] KNL_RAM address [Optional: ] [8L] KNL_RAM address [Optional: ] KNL_RAM [Explanation] This definition statement defines the address at which the kernel data is located. [FR] address: 0x to 0xfffffffc Address that is a multiple of four [16] address: 0x to 0xfffffe Even number address [8L] address: 0x0000 to 0xfffe Even number address If this definition statement is used twice to define the address where the kernel data is located, the definition that appears last is valid. This definition statement cannot be omitted. [Example] Locating the kernel code in addresses 0x Configuration file KNL_RAM 0x
126 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS USR_SECTION [FR] USR_SECTION section_name [, [address I territory_name]] [Optional: ] [16] USR_SECTION section_name [, [address I territory_name]] [Optional: ] [8L] USR_SECTION section_name [, [address I territory_name]] [Optional: ] USR_SECTION [Explanation] This definition statement defines the address at which a section used by the user program is located. If the address is omitted, the section is located immediately after the previously defined section. However, if no sections have been defined, the location address cannot be omitted. This definition statement can be specified as many times as necessary. If this definition statement is omitted, all sections are located automatically. Although the EIT table is automatically generated by the configurator, it can be located anywhere by using this definition statement. If the R_eit section is not specified, it is automatically located by the linker function at an available address. [Example] Locating the segments named code1 and code2 from the area CODE Configuration file ROM 0x20000,0x2ffff,CODE USR_SECTION code1+code2,code Locating the sections named code3 and code4 starting at address 0x1000 Configuration file USR_SECTION code3,0x1000 USR_SECTION code4, 108
127 MEMO 109
128 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SYSTEM_CALL [FR] SYSTEM_CALL {TSK I TSYNC I SEM I FLG I MBX I INT I MPL I MPF I TIM I SYS} [Optional: ] SYSTEM_CALL systemcall_name [16] [Optional: - ] [8L] [Optional: - ] SYSTEM_CALL [Explanation] This definition statement defines the system calls used by the system. System calls can be specified either by their function names or by their system call names. When a function name is specified, all system calls belonging to that function are regarded as having been specified. When a system call name is specified, only that system call is defined. TSK: Defines all of the system calls in the task management functions so that they can be used. The system calls sta_tsk, ext_tsk, ter_tsk, dis_dsp, ena_dsp, chg_pri, rot_rdq, rel_wai, get_tid, and ref_tsk can be used. (The effect is the same as if all of the listed system calls had been defined individually.) TSYNC: Defines all of the system calls in the task association synchronization functions so that they can be used. SEM: FLG: MBX: INT: The system calls sus_tsk, rsm_tsk, frsm_tsk, slp_tsk, tslp_tsk, wup_tsk, and can_wup can be used. (The effect is the same as if all of the listed system calls had been defined individually.) Defines all of the semaphore-related system calls so that they can be used. The system calls sig_sem, wai_sem, twai_sem, preq_sem, and ref_sem can be used. (The effect is the same as if all of the listed system calls had been defined individually.) Defines all of the eventflag-related system calls so that they can be used. The system calls set_flg, clr_flg, wai_flg, twai_flg, pol_flg and ref_flg can be used. (The effect is the same as if all of the listed system calls had been defined individually.) Defines all of the mailbox-related system calls so that they can be used. The system calls snd_msg, rcv_msg, trcv_msg, prcv_msg, trcu_msg and ref_mbx can be used. (The effect is the same as if all of the listed system calls had been defined individually.) Defines all of the system calls in the interrupt management functions so that they can be used. The system calls ret_int, loc_cpu, unl_cpu, chg_ilm, and ref_ilm can be used. (The effect is the same as if all of the listed system calls had been defined individually.) 110
129 3.2 Definition Statement Explanation MPL: MPF: TIM: SYS: This parameter defines all system calls to the fixed-size memorypool so that they can be used. The system calls "get_blf", "pget_blf", "tget_blf", "rel_blf", and "ref_mpf" can be used. (The effect is the same as if all of the listed system calls had been defined.) This parameter defines all system calls to the fixed-size memorypool so that they can be used. The system calls "get_blf", "pget_blf", "tget_blf", "rel_blf", and "ref_mpf" can be used. (The effect is the same as if all of the listed system calls had been defined.) Defines all of the system calls in the time management functions so that they can be used. The system calls set_tim, get_tim, dly_tsk, def_cyc, act_cyc, ref_cyc, def_alm ref_alm, and ret_tmr can be used. (The effect is the same as if all of the listed system calls had been defined individually.) Defines all of the system calls in the system management functions so that they can be used. The system calls get_ver and ref_sys can be used. (The effect is the same as if all of the listed system calls had been defined individually.) This definition statement can be defined as many times as necessary. If this definition statement is omitted, all system calls are selected in the target system. [Example] Defining all of the system calls in the task management functions and the system calls snd_msg and rcv_msg for use: Configuration file SYSTEM_CALL TSK SYSTEM_CALL snd_msg SYSTEM_CALL rcv_msg 111
130 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS TSK [FR] TSK name, entry [, [itskpri] [, [stack] [, [tskstat] [Optional: ] [, [stacd] [, [ID] [, [exinf] [, [tmo]]]]]]] [16] TSK name, [tskid], entry [, [itskpri] [, [stksz] [Optional: ] [, [RP_reg] [, [DTB] [, [ADB] [, [DPR] [, [CCR]]]]]]]] [8L] TSK name, [tskid], entry [, [itskpri] [, [stksz] [Optional: ] [, [RP_reg]]]] TSK [Explanation] This definition statement defines tasks. name: entry: itskpri: stack: tskstat: stacd: This parameter specifies the label under which the task ID is to be stored. (This parameter must not be omitted.) This parameter specifies the task entry by means of either a label name or an address. (This parameter must not be omitted.) This parameter specifies the numeric value for the task startup priority (the priority level when the task is started up). If this parameter is omitted, the priority level (the minimum priority) specified in the system definition is assumed. The task startup priority must be equal to or higher than the priority level. This parameter specifies either the size of the stack area used by the task, or else the name of the common stack. (See the description of the definition statement in Section , COM_STACK. ) If this parameter is omitted, the stack size is assumed to be 1024 bytes. When specifying a stack size, specify a size that is a multiple of four. The stack size can be roughly determined by using the Maximum stack usage calculation tool (musc), which is a standard tool provided with the FR C compiler. However, it is necessary to increase the portion (96 bytes) used for the task context information. This parameter specifies the status of the task at system startup. - DORMANT: The initial status of the task is DORMANT. - READY: The initial status of the task is READY. If this parameter is omitted, the initial status of the task is DORMANT. This parameter specifies as a numeric value the start code that is passed to the task when it is executed. This code is valid only when the initial status is READY ; this code is ignored if the initial status is DORMANT. If this parameter is omitted, 0 is assumed. 112
131 3.2 Definition Statement Explanation ID: exinf: tmo: This parameter specifies the task ID number as a numeric value. (ID: 1 to 32767) If the task ID is omitted, an available number is assigned automatically. Note that ID numbers must be specified consecutively. This parameter specifies extended information, by means of either a numeric value or a label name. If this parameter is omitted, 0 is assumed. This parameter specifies whether use of the object wait system call with a task time-out is to be allowed. NOTMO: Use of the object wait system call with a time-out is not allowed. TMO: Use of the object wait system call with a time-out is allowed. If this specification is omitted, "NOTMO" is assumed. When TMO is specified, the usable system calls are twai_sem, twai_flg, trcv_msg, and tget_blf. This definition places no restrictions on tslp_tsk and dly_tsk. [Example] Defining a task with the following parameters: Task name: Entry: Startup priority: Stack size: Initial status: Start code: Task ID: Extended information: Time-out function: tsk_1 tsk_1_entry Default value Default value Default value Default value Automatic assignment Default value Default value Configuration file TSK tsk_1,tsk_1_entry 113
132 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Defining a task with the following parameters: Task name: tsk_2 Entry: tsk_2_entry Startup priority: 3 Stack size: 0x1000 Initial status: READY Start code: 3 Task ID: Automatic assignment Extended information: 0xFFFFFFFF Time-out function: Allowed Configuration file TSK tsk_2,tsk_2_entry,3,0x1000,ready,3,,0xffffffff,tmo Note: Task stack size Define the task stack size with plenty of space. If the task stack size is insufficient, the target system will not operate correctly. TSK [16] [Explanation] This definition statement defines a task. This definition statement cannot be omitted. Set the priority level before defining the task. name: This parameter specifies the label indicating where the task ID is stored. (Required) tskid: This parameter specifies the task ID number (ID = 1 to 255). If the task ID is omitted, an available number is automatically assigned. Specify ID numbers consecutively. entry: This parameter specifies the task entry with the label name. (Required) itskpri: This parameter specifies the task activation priority (priority at task activation) with a numeric value. If the task activation priority is omitted, the lowest priority level (PRIORITY_LEVEL) specified by the system definition is used. The task activation priority must be higher than the priority level. stksz: This parameter specifies the size of the stack area to be used by the task as 0x000e to 0xfffe, or specifies the common stack name and stack name. If the stack size is omitted, 0x100 bytes are used. RP_reg: This parameter specifies RP registers 0 to 31. Do not specify register bank 1 114
133 3.2 Definition Statement Explanation because it is used by the kernel. If RP_reg is omitted, 0 is assumed. DTB: This parameter specifies data bank registers 0x00 to 0xff. If DTB is omitted, 0 is assumed. ADB: This parameter specifies additional data bank registers 0x00 to 0xff. If ADB is omitted, 0 is assumed. DPR: This parameter specifies direct page registers 0x00 to 0xff. If DPR is omitted, 0 is assumed. CCR: This parameter specifies condition code registers 0x00 to 0xff. If CCR is omitted, 0x40 (interrupt allowable, user stack usable) is assumed. [Example] Defining a task with the following parameters: Task name: tsk_1 Task ID: 3 Entry: tsk_1_entry Initial priority: 5 Stack size: 0x1000 RP register: 0 Data bank register: 0x10 Additional data bank register: 0x50 Direct page register: 0x80 Condition code register: 0x40 Configuration file TSK tsk_1,3,tsk_1_entry,5,0x1000,0,0x10,0x50,0x80,0x40 115
134 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Defining a task with the following parameters: Task name: Task ID: Entry: Initial priority: Stack size: RP register: Data bank register: Additional data bank register: Direct page register: Condition code register: tsk_2 Automatic tsk_2_entry Omitted tsk_1 Omitted Omitted Omitted Omitted Omitted Configuration file TSK tsk_2,,tsk_2_entry,,tsk_1 Defining a task with the following parameters: Task name: Task ID: Entry: Initial priority: Stack size: RP register: Data bank register: Additional data bank register: Direct page register: Condition code register: tsk_3 Automatic tsk_3_entry Omitted Omitted Omitted Omitted Omitted Omitted 0x44 Configuration file TSK tsk_3,,tsk_3_entry,,,,,,,0x44 116
135 3.2 Definition Statement Explanation TSK [8L] [Explanation] This definition statement defines a task. This definition statement cannot be omitted. Set the priority level before defining the task. name: This parameter specifies the label indicating where the task ID is stored. (Required) tskid: This parameter specifies the task ID number (ID = 1 to 127). If the task ID is omitted, an available number is automatically assigned. Specify ID numbers consecutively. entry: This parameter specifies the task entry with the label name. (Required) itskpri: This parameter specifies the task activation priority (priority at task activation) with a numeric value. If the task activation priority is omitted, the lowest priority level (PRIORITY_LEVEL) specified by the system definition is used. The task activation priority must be higher than the priority level. stksz: This parameter specifies the sizes of the stack area to be used by the task as 0x000e to 0x2000, or specifies the common stack name and stack name. If the stack size is omitted, 40 bytes are used. RP_reg: This parameter specifies RP registers 1 to 31. Do not specify register bank 0 because it is used by the kernel. If RP_reg is omitted, 1 is assumed. [Example] Defining a task with the following parameters: Task name: tsk_1 Task ID: 1 Entry: tsk_1_entry Initial priority: 4 Stack size: 0x40 RP register: 1 Configuration file TSK tsk_1,1,tsk_1_entry,4,0x40,1 117
136 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Defining a task with the following parameters: Task name: tsk_2 Task ID: Automatic Entry: tsk_2_entry Initial priority: Omitted Stack size: Omitted (40) RP register: Omitted (1) Configuration file TSK tsk_2,,tsk_2_entry Defining a task with the following parameters: Task name: tsk_3 Task ID: Automatic Entry: tsk_3_entry Initial priority: Omitted Stack size: Omitted (40) RP register: 6 Configuration file TSK tsk_3,,tsk_3_entry,,,6 118
137 MEMO 119
138 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS COM_STACK [FR] COM_STACK name [,[size]] [Optional: ] [16] COM_STACK name [,[size]] [Optional: ] [8L] COM_STACK name [,[size]] [Optional: ] COM_STACK [Explanation] This definition statement defines task common stacks. name: size: This parameter specifies the name of the common stack. (This parameter must not be omitted.) This parameter specifies the size of the common stack. For F 2 MC-16, the common stack size can be specified from 14 to 0xfffe. For F 2 MC-8L, the common stack size can be specified from 0x000e to 0x2000. If this parameter is omitted, the following sizes are assumed: [FR] 0x400 bytes [16] 0x100 bytes [8L] 40 bytes When a common stack is used, one stack can be shared by more than one task. An error is generated if the same common stack name is specified twice. Note: When multiple tasks that are sharing a stack (using the same common stack) are in a state other than the DORMANT state (READY, WAIT, etc.) simultaneously, the target system will not operate correctly. Tasks that operate simultaneously must either use different common stacks or else must not use 120
139 3.2 Definition Statement Explanation common stacks. (See Figure ) Task A READY Using the common stack Using the common stack Common stack I Task B READY Figure Example Where the Common Stack Cannot Function Properly In this example, task A and task B are both in the READY state, and are both using common stack I. As a result, the two tasks destroy each other s stack, with the result that the system will not operate properly. [Example] Setting up the common stack com_stack for use by the tasks tsk_1 and tsk_2 : Configuration file COM_STACK com_stack,0x2000 TSK tsk_1,tsk_1_entry,5,com_stack,ready TSK tsk_2,tsk_2_entry,5,com_stack,dormant 121
140 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SEM_ICNT [FR] [Optional: - ] [16] SEM_ICNT icnt [Optional: ] [8L] SEM_ICNT icnt [Optional: ] SEM_ICNT [Explanation] This definition statement is defined when the same initial count value, which is fixed, is set for each semaphore ID. The initial count value can be 0 to 255. If this definition statement is omitted, specify an initial count for each ID. [Example] Defining a semaphore initial count value as the fixed value 128 Configuration file SEM_ICNT
141 MEMO 123
142 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SEM [FR] SEM name [, [isemcnt] [, [maxcnt] [, [ID] [Optional: ] [, [exinf]]]]] [16] SEM name [, [semid] [, [isemcnt]]] [Optional: ] [8L] SEM name [, [semid] [, [isemcnt]]] [Optional: ] SEM [FR] [Explanation] This definition statement defines semaphores. name: This parameter specifies the label under which the semaphore ID is to be stored. (This parameter must not be omitted.) isemcnt: This parameter specifies the count (number of resources) at system startup as a numeric value ranging from 0 to If this parameter is omitted, 1 is assumed. maxcnt: This parameter specifies the maximum value for the semaphore count as a numeric value. ID: exinf: If this parameter is omitted, is assumed. This parameter specifies as a numeric value the semaphore ID number. (ID: 1 to 32767) If this parameter is omitted, an available number is assigned automatically. Note that ID numbers must be specified consecutively. This parameter specifies extended information, by means of either a numeric value or a label name. If this parameter is omitted, 0 is assumed. [Example] Defining a semaphore with the following parameters: Semaphore name: sem_1 Initial count: 10 Maximum count: 20 Semaphore ID: 3 Extended information: 0xFFFF Configuration file SEM sem_1,10,20,3,0xffff 124
143 3.2 Definition Statement Explanation Defining a semaphore with the following parameters: Semaphore name: Initial count: Maximum count: Semaphore ID: Extended information: sem_2 Default value Default value Automatic assignment Default value Configuration file SEM sem_2 Defining a semaphore with the following parameters: Semaphore name: sem_3 Initial count: 10 Maximum count: 20 Semaphore ID: Extended information: Automatic assignment 0xFFFFFFFF Configuration file SEM sem_3,10,20,,0xffffffff 125
144 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS SEM [16][8L] [Explanation] This definition statement defines a semaphore. name: This parameter specifies the label indicating where the semaphore ID is stored. (Required) semid: This parameter specifies the semaphore ID number as a numeric value (ID = 1 to 127). If the semaphore ID is omitted, an available number is automatically assigned. Specify ID numbers consecutively. isemcnt: This parameter specifies the count value as a numeric from value 0 to 255 at system activation. If this parameter is omitted, 1 is assumed for the FMC-16 and 0 is assumed for the FMC-8L. If the SEM_ICNT definition statement is specified, count values at system activation are ignored. [Example] Defining a semaphore with the following parameters: Semaphore name: sem_1 Semaphore ID: 3 Initial count: 10 Configuration file SEM sem_1,3,10 Defining a semaphore with the following parameters: Semaphore name: sem_2 Semaphore ID: Automatic Initial count: Omitted (0) Configuration file SEM sem_2 126
145 3.2 Definition Statement Explanation Defining a semaphore with the following parameters: Semaphore name: Semaphore ID: Initial count: sem_3 Automatic 2 (fixed) Configuration file SEM_ICNT 2 SEM sem_2 127
146 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS FLG_BIT [FR] [Optional: - ] [16] FLG_BIT { 16BIT I 1BIT} [Optional: ] [8L] [Optional: - ] FLG_BIT [Explanation] Defines an eventflag type. 16BIT 1BIT This definition should be made before eventflags are defined. Eventflag type definition should not be changed during the course of eventflag definition. If this definition statement is omitted, the value will be 1BIT. [Example] To designate 16-bit control pattern Configuration file FLG_BIT 16BIT FLG flg_1,1,0xffff To designate 1-bit control pattern Configuration file FLG_BIT 1BIT FLG flg_1,1,1 128
147 FLG_PATTERN 3.2 Definition Statement Explanation [FR] [Optional: - ] [16] FLG_PATTERN pattern [Optional: ] [8L] [Optional: - ] FLG_PATTERN [Explanation] Defines whether an initial pattern value is to be fixed or variable by ID for the eventflag definition statement (FLG). Be sure to define the eventflag type (FLG_BIT) before making this definition. If the FLG_BIT statement designates the 1-BIT type, the allowable range is 0 to 1. If the FLG_BIT statement designates the 16-BIT type, the allowable range is 0 to 0xffff. Values outside the allowable range will result in an error. If this definition statement is omitted, the initial pattern should be designated with the eventflag definition statement (FLG). [Example] To set the eventflag initial pattern value to 1 Configuration file FLG_BIT 1BIT FLG_PATTERN 1 To set the eventflag initial pattern value to 0x8000 Configuration file FLG_BIT FLG_PATTERN 16BIT 0x
148 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS FLG [FR] FLG name [, [iflgptn] [, [flgid][, [exinf]]]] [Optional: ] [16] FLG name [, [flgid] [, [iflgptn]]] [Optional: ] [8L] FLG name [, flgid] [Optional: ] FLG [Explanation] This definition statement defines eventflags. name: iflgptn: This parameter specifies the label under which the eventflag ID is to be stored. (This parameter must not be omitted.) This parameter specifies the initial pattern of the eventflag as a numeric value. For the FR, the initial pattern value can be 0 to 0xffffffff. For the F 2 MC-16, the initial pattern value is specified as 0 or 1 when the FLG_BIT definition is 1 bit. If The FLG_BIT definition is 16 bits, the initial pattern value can be 0 to 0xffff. If any value other than these values is specified, an error occurs. If a fixed initial pattern (FLG_PATTERN) is defined, a defined initial pattern value is ignored. If this parameter is omitted, 0 is assumed. flgid: This parameter specifies the ID number of the eventflag as a numeric value. (1 to for the FR, 1 to 127 for the F 2 MC-16 and F 2 MC-8L) exinf: [Example for FR] If this parameter is omitted, an available number is automatically assigned. Specify ID numbers consecutively. This parameter specifies extended information, by means of either a numeric value or a label name. If this parameter is omitted, 0 is assumed. Defining an eventflag with the following parameters: Eventflag name: Initial pattern: 5 Eventflag ID: 3 flg_1 Extended information: 0xFFFF Configuration file FLG flg_1,5,3,0xffff 130
149 3.2 Definition Statement Explanation Defining an eventflag with the following parameters: Eventflag name: Initial pattern: Eventflag ID: Extended information: flg_2 Default value Automatic assignment Default value Configuration file FLG flg_2 Defining an eventflag with the following parameters: Eventflag name: Initial pattern: Eventflag ID: Extended information: flg_3 0x0E0E Automatic assignment 0xFFFFFFFF Configuration file FLG flg_3,0x0e0e,,0xffffffff [Example for F 2 MC-16] Defining an eventflag with the following parameters: Eventflag management method: 16 bits Eventflag name: flg_1 Eventflag ID: 3 Initial pattern: 5 Configuration file FLG_BIT 16BIT FLG flg_1,3,0x
150 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS Defining an eventflag with the following parameters: Eventflag management method: 1 bits Eventflag name: flg_2 Eventflag ID: Automatic Initial pattern: Default value (0) Configuration file FLG_BIT 1BIT FLG flg_2 [Example for F 2 MC-8L] Defining an eventflag with the following parameters: Eventflag name: flg_1 Eventflag ID: 3 Configuration file FLG flg_1,3 Defining the eventflag with the following parameters: Eventflag name: flg_2 Eventflag ID: Automatic Configuration file FLG flg_2 132
151 MEMO 133
152 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS MBX [FR] MBX name [, [mbxid] [, [exinf]]] [Optional: ] [16] MBX name [, mbxid] [Optional: ] [8L] MBX name [, mbxid] [Optional: ] MBX [Explanation] This definition statement defines mailboxes. name: This parameter specifies the label under which the mailbox ID is to be stored. (This parameter must not be omitted.) mbxid: This parameter specifies the mailbox ID number as a numeric value. (1 to for the FR, 1 to 127 for the FMC-16 and FMC-8L) exinf: If this parameter is omitted, an available number is automatically assigned. Specify ID numbers consecutively. This parameter specifies extended information, by means of either a numeric value or a label name. If this parameter is omitted, 0 is assumed. [Example] Defining a mailbox with the following parameters: Mailbox name: mbx_1 Mailbox ID: 3 Extended information: 0xFFFF Configuration file MBX mbx_1,3,0xffff 134
153 3.2 Definition Statement Explanation Defining a mailbox with the following parameters: Mailbox name: Mailbox ID: Extended information: mbx_2 Automatic assignment Default value Configuration file MBX mbx_2 Defining a mailbox with the following parameters: Mailbox name: Mailbox ID: Extended information: mbx_3 Automatic assignment 0xFFFFFFFF Configuration file MBX mbx_3,,0xffffffff 135
154 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS MPL [FR] MPL name, mplsiz, blksiz [, [ID] [, [exinf]]] [Optional: ] [16] MPL name, [mplid], mplsiz, blk [Optional: ] [8L] [Optional: - ] MPL [FR] [Explanation] This definition statement defines memorypools. name: mplsiz: This parameter specifies the label under which the memorypool ID is to be stored. (This parameter must not be omitted.) This parameter specifies the size of the entire memorypool as a number of bytes. (This parameter must not be omitted.) Specify the memorypool size so that it is a multiple of four bytes. blksiz: This parameter specifies the block size as a numeric value. (This parameter must not be omitted.) Specify the block size so that it is a multiple of four bytes, with a minimum of 20 bytes. If a block size that is greater than the size of the entire memorypool (mplsiz) is specified, an error results. ID: This parameter specifies as a numeric value the memorypool ID number. (ID: 1 to 32767) If this parameter is omitted, an available number is assigned automatically. Note that ID numbers must be specified consecutively. exinf: This parameter specifies extended information, by means of either a numeric value or a label name. If this parameter is omitted, 0 is assumed. [Example] Defining a memorypool with the following parameters: Memorypool name: mpl_1 Memorypool size: 2048 Block size: 256 Memorypool ID: 3 Extended information: 0xFFFF Configuration file MPL mpl_1,2048,256,3,0xffff 136
155 3.2 Definition Statement Explanation Defining a memorypool with the following parameters: Memorypool name: mpl_2 Memorypool size: 2048 Block size: 256 Memorypool ID: Automatic assignment Extended information: Default value Configuration file MPL mpl_2,2048,256 Defining a memorypool with the following parameters: Memorypool name: mpl_3 Memorypool size: 2048 Block size: 256 Memorypool ID: Automatic assignment Extended information: 0xFFFFFFFF Configuration file MPL mpl_3,2048,256,,0xffffffff MPL [16] [Explanation] This definition statement defines a fixed-size memorypool. name: This parameter specifies the label indicating where the fixed-size memorypool ID is stored. (Required) mplid: This parameter specifies the fixed-size memorypool ID as a numeric value (1 to 127). If the fixed-size memorypool ID is omitted, an available number is automatically assigned. Specify ID numbers consecutively. (Optional) mplsiz: This parameter specifies the size of a single fixed-size memorypool as a byte count. Specify the size of a single fixed-size memorypool as an even number byte value in the range from 0x0004 to 0xfffe. (Required) blk: This parameter specifies the number of blocks in the range from 0x0001 to 0x3fff. Define this parameter so that the entire size of the fixed-size memorypool for each ID is within 64K bytes. (Required) 137
156 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS [Example] Defining a fixed-size memorypool with the following parameters: Fixed-size memorypool name: mpl_1 Fixed-size memorypool ID: 3 Fixed-size memorypool size: 2048 Number of blocks: 10 Configuration file MPL mpl_1,3,2048,10 Defining a fixed-size memorypool with the following parameters: Fixed-size memorypool name: mpl_1 Fixed-size memorypool ID: Automatic Fixed-size memorypool size: 1024 Number of blocks: 20 Configuration file MPL mpl_1,,1024,20 138
157 MEMO 139
158 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS MPF [FR] MPF name, mpfcnt, blksiz [, [ID] [, [exinf]]] [Optional: ] [16] [Optional: - ] [8L] [Optional: - ] MPF [FR] [Explanation] This definition statement defines a fixed-size memorypool. name: This parameter specifies the label indicating where the fixed-size memorypool ID is stored. (Required) mpfcnt: This parameter specifies the number of blocks in the entire fixed-size memorypool. (Required) blksiz: This parameter specifies the block size as a numeric value. (Required) Specify the block size as a byte count that is a multiple of four. The minimum is 20 bytes. The size of the entire fixed-size memorypool is blksiz x mpfcnt. ID: This parameter specifies the ID number of the fixed-size memorypool as a numeric value (ID = 1 to 32767). If this parameter is omitted, an available number is automatically assigned. Specify ID numbers consecutively. exinf: This parameter specifies the extended information as a numeric value or label. If this parameter is omitted, 0 is assumed. [Example] Defining a memorypool with the following parameters: Fixed-size memorypool name: mpf_1 Number of blocks in the entire fixed-size memorypool: 10 Block size: 256 Fixed-size memorypool ID: 3 Extended information: 0xFFFF Configuration file MPL mpf_1,10,256,3,0xffff 140
159 3.2 Definition Statement Explanation Defining a fixed-size memorypool with the following parameters: Fixed-size memorypool name: mpl_2 Number of blocks in the entire fixed-size memorypool: 10 Block size: 256 Fixed-size memorypool ID: Automatic Extended information: Default value Configuration file MPF mpf_2,10,256 Defining a fixed-size memorypool with the following parameters: Fixed-size memorypool name: mpl_3 Number of blocks in the entire fixed-size memorypool: 10 Block size: 256 Fixed-size memorypool ID: Automatic Extended information: 0xFFFFFFFF Configuration file MPF mpf_3,10,256,,0xffffffff 141
160 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS EIT_ENTRY [FR] EIT_ENTRY eit_no, entry [Optional: ] [16] EIT_ENTRY eit_no, entry [Optional: ] [8L] EIT_ENTRY eit_no, entry [Optional: ] EIT_ENTRY [Explanation] This definition statement defines EIT vectors. [FR] eit_no: entry: [16] [8L] eit_no: entry: This parameter specifies the vector number. (This parameter must not be omitted.) Excluding those reserved for the system, the following vector numbers may be specified: 16 to 62, and 65 to 255. Vector numbers 0 to 15, 63 and 64 are reserved by the system and cannot be defined by users. This parameter specifies the EIT vector entry by means of either a label name or an address. (This parameter must not be omitted.) This parameter defines the IRQ n number. This parameter specifies the interrupt vector entry with a label or an address value. Define the timer handler for the kernel system clock here. For the F 2 MC-16, 11 to 41, excluding system-reserved values, can be assigned as interrupt numbers. Since interrupt numbers 8, 9, and 10 are reserved by the system, a user cannot define them. For the F 2 MC-8L, interrupt numbers can be assigned 0 to 11. [Example] Defining an EIT vector with the following parameters: Vector number: 28 Entry: int_28_entry Configuration file EIT_ENTRY 28,int_28_entry 142
161 3.2 Definition Statement Explanation Defining an interrupt handler with the following parameters: Interrupt number: 7 Entry: _sci0_tx_hdr Configuration file EIT_ENTRY 7,_sci0_tx_hdr Note: Interrupt handlers Interrupt handlers must be defined for all interrupts (vector numbers 16 to 62) that are generated in the target system. If an interrupt for which no interrupt handler is defined is generated, the user s system down processing may be executed and the target system may not be able to continue with its processing correctly. 143
162 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS INIT_HDR_ENTRY [FR] [Optional: - ] [16] INIT_HDR_ENTRY entry [Optional: ] [8L] INIT_HDR_ENTRY entry [Optional: ] INIT_HDR_ENTRY [Explanation] Defines the entry for the initialization handler called at operating system startup. If more than one initialization handler definition is made using this definition statement, the last definition will be valid. If this definition statement is omitted, the initialization handler name will be _inihdr. Note that initialization handlers must be created by the user. The initialization handler performs operations including startup of initialization tasks. [Example] To define an initialization handler with the entry _inithdr Configuration file INIT_HDR_ENTRY _inithdr 144
163 CALL_ENTRY 3.2 Definition Statement Explanation [FR] [Optional: - ] [16] [Optional: - ] [8L] CALL_ENTRY entry, call_no [Optional: ] CALL_ENTRY [Explanation] This definition statement defines a call vector. entry: This parameter specifies the label of the call vector. (Required) call_no: This parameter specifies the call vector number. (Required) Call vector numbers can be from 2 to 7. If this definition statement is omitted, a user does not define the call vector. [Example] Defining a call vector with the following parameters: Vector number: 7 Entry: cycle_set Configuration file CALL_ENTRY cycle_set,7 Defining a call vector with the following parameters: Vector number: 2 Entry: sta_tsk Configuration file CALL_ENTRY sta_tsk,2 145
164 CHAPTER 3 CONFIGURATION DEFINITION STATEMENTS RESET_ENTRY [FR] RESET_ENTRY entry [Optional: ] [16] RESET_ENTRY entry [Optional: ] [8L] RESET_ENTRY entry [Optional: ] RESET_ENTRY [Explanation] This definition statement defines a reset vector. If this statement is used twice to define a reset vector, the definition that appears last is valid. If this definition statement is omitted, the reset vector name is _sys_entry. [Example] Defining the entry name of a reset vector as _sys_entry Configuration file RESET_ENTRY _sys_entry 146
165 PART 2 NON-WINDOWS VERSION Part 2 describes how to operate the non-windows version of the configurator. Chapter 4 Operation of the Non-Windows Version 147
166 MEMO 148
167 CHAPTER 4 OPERATION OF THE NON-WINDOWS VERSION This chapter explains the operation of the non-windows version of the configurator. This chapter explains the startup method and options. The non-windows version of the configurator is the configurator used under the DOS prompt. 4.1 Configurator Startup Command 4.2 Option for the Monitor Debugger 149
168 CHAPTER 4 OPERATION OF THE NON-WINDOWS VERSION 4.1 Configurator Startup Command The following is the startup statement for the configurator: [FR] frcfs[-v] [-XV] [-help] [-a] [-f configuration-file-name] [16] frcfs[-v] [-XV] [-help] [-a] [-jmp] [-f configuration-file-name] [8L] frcfs[-v] [-XV] [-help] [-a] [-f configuration-file-name] Configurator Startup Command Description The configurator startup command starts the REALOS configurator. One of the two operating modes may be specified for the configurator as follows: When the -a option is specified: After assembling a kernel source file, the resulting kernel object file is linked with user relocatable object files. When the FR is used, the kernel object file is generated under $RTOS\rtos\911\obj, where it also remains after execution. When the FMC-16 or FMC-8L is used, a library file is generated. When the configuration file is modified, the kernel object file must be generated again. When the -a option is not specified: A kernel object file under $RTOS\rtos\911\obj is linked with user object files. Since this method does not assemble the kernel source file, a system can be built quickly. When the embedded version is used, the -a option must be specified to generate a kernel object file in advance. Reference: $RTOS indicates a directory defined by the RTOS environment variable. Options -V -XV -help -a -jmp [16] Displays the version of the configurator. Does not display the version of the configurator. Displays help. Assembles a kernel source file, and links the generated kernel object file and user object files. See Section 4.2, Option for the Monitor Debugger. 150
169 4.1 Configurator Startup Command -f Specifies a configuration file. Whenever this option is specified, a configuration file must be specified. The suffix of the configuration file name cannot be omitted. -GHS [FR] Specify this option when using a tool supplied by GHS. Startup examples % frcfs The configurator displays the version and help, then terminates. % frcfs -V -f realos.rcf After displaying the version, the configurator reads configuration file realos.rcf, and performs configuration. Note: Since the configurator activates the assembler and linker during internal processing, the directory holding each of these tools must be defined in the PATH environment variable in advance. Before the configurator can start, the RTOS environment variable must have been defined on the host machine. When executing configuration, the configurator reads files under the directory defined by the RTOS environment variable. Therefore, before starting the configurator, be sure to define the directory in which REALOS is installed. The configurator uses an intermediate file that is created under the directory defined by the TMP environment variable. If the configurator is executed when this environment variable is not defined, the intermediate file is created under the current directory. 151
170 CHAPTER 4 OPERATION OF THE NON-WINDOWS VERSION 4.2 Option for the Monitor Debugger The -jmp option outputs an interrupt vector table as a jump table. This function is available only for the F 2 MC-16 family. Option for the Monitor Debugger The configurator usually creates a vector table for vector addresses specified with the EIT_ENTRY and RESET_ENTRY configuration definition statements. When the -jmp option is specified, this vector table is created as a jump table. The vector addresses specified with the configuration definition statements shown in Figure 4.2a are usually output as the vector table shown in Figure 4.2b. EIT_ENTRY EIT_ENTRY RESET_ENTRY uarttxint,13 uartrxint,11 reset_entry Figure 4.2a Configuration Definition Statements.SECTION INTVEC, CODE, ALIGN=1.DATA.L r97_dispatch ; (IRQ42/ICR15).DATA.L 0 ; (IRQ41/ICR15) : :.DATA.L 0 ; (IRQ14/ICR 1).DATA.L uarttxint ; (IRQ13/ICR 1).DATA.L 0 ; (IRQ12/ICR 0).DATA.L uartrxint ; (IRQ11/ICR 0).DATA.L r97_cpu_expt ; (IRQ10/-----).DATA.L 0 ; (IRQ9 /-----).DATA.E _sys_entry ; (IRQ8 /-----).DATA.B 0 x 88.END Note:The vector address in IRQ42 is always registered by the configurator. The vector address in IRQ10 is registered only when the CPU exception function has been included. Figure 4.2b Output Example of an Interrupt Vector Table 152
171 4.2 Option for the Monitor Debugger.SECTION INTVEC, CODE, ALIGN=1 jmpp r97_dispatch ; (IRQ42/ICR15) jmpp 0 ; (IRQ41/ICR15) : : jmpp 0 ; (IRQ14/ICR 1) jmpp uarttxint ; (IRQ13/ICR 1) jmpp 0 ; (IRQ12/ICR 0) jmpp uartrxint ; (IRQ11/ICR 0) jmpp r97_cpu_expt ; (IRQ10/-----) jmpp 0 ; (IRQ9 /-----) jmpp _sys_entry ; (IRQ8 /-----).END Note:The vector address in IRQ42 is always registered by the configurator. The vector address in IRQ10 is registered only when the CPU exception function has been included. Figure 4.2c Output Example of a Jump Table 153
172 MEMO 154
173 PART 3 SOFTUNE WORKBENCH VERSION OF THE CONFIGURATOR Part 3 describes how to operate the Softune Workbench version (hereafter Workbench version) of the configurator, and also explains the definition dialogs for creating configuration files. Chapter 5 Information for Softune Workbench Users Chapter 6 Operation of the Workbench Version of the Configurator Chapter 7 Definition Dialogs in the Workbench Version of the Configurator Chapter 8 Limitations of the Workbench Version of the Configurator 155
174 MEMO 156
175 CHAPTER 5 INFORMATION FOR SOFTUNE WORKBENCH USERS This chapter provides information you need to know before using the Workbench version of the configurator as well as outlines the Workbench version of the configurator. 5.1 Outline of the Workbench Version of the Configurator 157
176 CHAPTER 5 INFORMATION FOR SOFTUNE WORKBENCH USERS 5.1 Outline of the Workbench Version of the Configurator This section outlines and provides notes on the Workbench version of the configurator. Outline of the Workbench Version of the Configurator REALOS configurator add-in module for Softune Workbench The REALOS configurator add-in module is a REALOS function expansion module for Softune Workbench. The module is in the form of a dynamic link library (DLL) form, allowing it to be linked dynamically with Softune Workbench. Softune Workbench itself does has no REALOS support function. If, however, the REALOS configurator add-in is installed, Softune Workbench is automatically expanded so that the REALOS support function can be used. Added functions The following functions are added: A choice of whether to include the REALOS kernel (REALOS(ABS) is added to [Project Type] of [Create New Project]. Figure 5.1a shows an example of the [Create New Project] dialog. Figure 5.1a [Create New Project] dialog.(fr) 158
177 5.1 Outline of the Workbench Version of the Configurator REALOS configuration setting screens are added. (System, memory, system call, task, semaphore, event flag, mailbox, memory pool, vector, and CPU setting dialogs are added.) Figure 5.1b shows an example of the system definition dialog. Figure 5.1b Example of the System Definition Dialog (FR) Linkage with the make function is enabled. When the REALOS configuration is modified, the system can be rebuilt automatically just by pressing the make button. 159
178 CHAPTER 5 INFORMATION FOR SOFTUNE WORKBENCH USERS Help information about the REALOS configurator is added to Softune Workbench help. - Pressing the F1 key with a system call name selected on the edit screen displays help information about the REALOS system call. Figure 5.1c shows an example of displaying help information about a system call (ext_tsk) with a single operation. Figure 5.1c Example of Displaying Help Information about a System Call with a Single Operation Note:The REALOS configurator add-in module (SiRcf.DLL file) is supplied with the REALOS product. If just Softune Workbench itself is installed, the REALOS support function cannot be used. When the Softune REALOS product is purchased, Softune Workbench functions are expanded automatically just by installing Softune REALOS. This means that when REALOS is revised in the future by adding or modifying configuration functions or by modifying the contents of help files, only the REALOS product needs to be revised. In this way, Softune Workbench functions will be modified automatically. Figure 5.1d shows the relationships between Softune Workbench and REALOS. 160
179 5.1 Outline of the Workbench Version of the Configurator Softune Workbench product package REALOS product package REALOS product set Softune Workbench program REALOS configurator add-in module Basic installation Additional installation Softune Workbench REALOS function expansion DLL Figure 5.1d Relationship of Softune Workbench and REALOS External reference symbol file Based on the object file names defined in the configuration file (tasks, semaphores, event flags, mailboxes, and variable-size and fixed-size memory pools), the configurator creates an external reference symbol file. The external reference symbol file is created under the name R_project-file-name.h in the current directory in which a project has been created with Softune Workbench. When the external reference symbol file name (for example, R_project-file-name.h) is included in a user program, symbols can be referenced. Note: An external reference symbol file is created each time [Project]-[Make or Build] is performed with Softune Workbench. 161
180 MEMO 162
181 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR This chapter explains how to operate the Workbench version of the configurator. In the Workbench version of the configurator, editing configuration data is simple because related configuration data is grouped into several dialogs, making the data visually easy to understand. The subsections entitled Related Definition Names that appear in the explanations indicate definition statements that set and change the configuration file. 6.1 Starting the Workbench Version of the Configurator 6.2 Editing the Configuration File 6.3 Making a Project 163
182 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR 6.1 Starting the Workbench Version of the Configurator There are two methods for starting the Workbench version of the configurator. Starting the Workbench Version of the Configurator The method for starting the configurator to create a new project depends on whether anew configuration file or an existing configuration file will be used. 164
183 6.1 Starting the Workbench Version of the Configurator Starting the Configurator with a New Configuration File This section explains the startup procedure used when a new configuration file is created. When Starting the Configurator with a New Configuration File First, select [New] from the file menu of the Softune Workbench main window. Figure 6.1.1a shows an example of the Softune Workbench main window. Figure 6.1.1a Example of the Softune Workbench Main Window (FR) 165
184 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR Next, from the [New] dialog, select [Project file]. Figure 6.1.1b shows an example of the [New] dialog of Softune Workbench. Figure 6.1.1b Example of the [New] Dialog of Softune Workbench Select [REALOS(ABS)] in [Project Type], and specify a project name in the [Project Name] field. Figure 6.1.1c shows an example of the [Create New Project] dialog of Softune Workbench. Figure 6.1.1c Example of the [Create New Project] Dialog of Softune Workbench Clicking the [OK] button opens the [Create Configuration File] dialog. Figure 6.1.1d shows an example of the [Create Configuration File] dialog. 166
185 6.1 Starting the Workbench Version of the Configurator Figure 6.1.1d Example of the [Create Configuration File] Dialog Select [New making], then click the [OK] button. The [System] dialog opens. (When [New making] is selected, a wizard dialog is opened.) Figure 6.1.1e shows an example of the [System] dialog. Figure 6.1.1e Example of the [System] Dialog (FR) Enter information in the fields in the dialog, and click the [Next] button to continue making settings for the configurator. When the settings are complete, click the [Finish] button. A configuration file is created. 167
186 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR Note: When the [Finish] button is clicked after configuration data has been set under [New making], the warning message shown in Figure 6.1.1f appears. Select the linker tab from the [Setup Tool Option] dialog in the project menu of Softune Workbench, select [Placement/Connection] from the category, and set the ROM and RAM areas. Figure 6.1.1f Example of the Warning Message 168
187 MEMO 169
188 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR Starting the Configurator by Using an Existing Configuration File This section explains the startup procedure used when an existing configuration file is read. When Starting the Configurator by Using an Existing Configuration File Open the [Create Configuration File] dialog shown in Figure 6.1.1d by following the same steps used to create a new configuration file. From the [Create Configuration File] dialog, select [An existing Configuration file]. Figure 6.1.2a shows an example of the [Create Configuration File] dialog. Figure 6.1.2a Example of the [Create Configuration File] Dialog After entering a file name, click the [OK] button. The [Set Configuration File] dialog (system definition) opens. (When [An existing Configuration file] is selected, a tabbed dialog opens.) Figure 6.1.2b shows an example of the [Set Configuration File] dialog. 170
189 6.1 Starting the Workbench Version of the Configurator Figure 6.1.2b Example of the [Set Configuration File] Dialog Open a dialog that you want to modify. (Clicking a tab changes the display to an associated setting screen.) Edit the settings. After editing is complete, click the [OK] button. The configuration file is edited. Note: When editing is performed with [An existing Configuration file] selected, the message shown in Figure 6.1.2c appears, since the relocatable object file (user object file) and library file defined in the configuration file are not reflected in Softune Workbench. Select [Add Member] from the Softune Workbench project menu, and add the user object file or library file. Figure 6.1.2c Example of the Warning Message Dialog 171
190 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR 6.2 Editing the Configuration File This section explains how to edit the configuration file after opening an existing project file. Editing the Configuration File When an existing project file is opened, the configuration file (sample.rcf) is added to the project window, as shown in Figure 6.2a. Figure 6.2a shows an example of the Softune Workbench project window. Figure 6.2a Example of the Softune Workbench Project Window 172
191 6.2 Editing the Configuration File To edit the configuration file, double-click its name. The [Set Configuration File] dialog opens. Use this dialog for configurator editing. Figure 6.2b shows an example of the [Set Configuration File] dialog. Figure 6.2b Example of the [Set Configuration File] Dialog Open the dialog you want to modify. After editing is complete, click the [OK] button. The configuration file is edited. 173
192 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR 6.3 Making a Project This section explains the procedure for assembling a kernel source file, then compiling and linking it with user source files to create an absolute object file. Making a Project After specifying configuration data, select [Add Member] from the project menu of Softune Workbench. Figure 6.3a shows an example of the [Add Member] menu item of Softune Workbench. Figure 6.3a Example of the [Add Member] Menu Item of Softune Workbench 174
193 6.3 Making a Project The [Add Member] dialog opens. Select and register user source files or library files you want to link with the kernel source. Figure 6.3b shows an example of the [Add Member] dialog. Figure 6.3b Example of the [Add Member] Dialog 175
194 CHAPTER 6 OPERATION OF THE WORKBENCH VERSION OF THE CONFIGURATOR After completing registration, select [Make] or [Build] from the project menu of Softune Workbench. Compilation, assembling, and linkage are performed. Figure 6.3c shows an example of the [Build] menu item of Softune Workbench. Figure 6.3c Example of the [Build] Menu Item of Softune Workbench Softune Workbench assembles the kernel and compiles and links user source files. Figure 6.3d shows the execution results. 176
195 6.3 Making a Project Figure 6.3d Example of Compilation and Linkage Execution Results 177
196 MEMO 178
197 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR This chapter explains how to set definition dialogs in the Workbench version of the configurator and also explains the organization of these dialogs. 7.1 Definition Dialog Organization 7.2 System Definition Dialog 7.3 Memory Definition Dialog 7.4 System Call Definition Dialog 7.5 Task Definition Dialog 7.6 Semaphore Definition Dialog 7.7 EventFlag Definition Dialog 7.8 Mail Box Definition Dialog 7.9 Variable-size MemoryPool Definition Dialog 7.10 Fixed-size MemoryPool Definition Dialog 7.11 Vector Definition Dialog 7.12 CPU Setup Dialog 7.13 Debug Setup Dialog 179
198 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.1 Definition Dialog Organization This section explains the operations and functions of the following five buttons that are common to all definition dialogs: [Next] button [Back] button [Finish] button [OK] button [Cancel] button Common buttons The dialogs that appear when a new configuration file is created (called wizard dialogs) have the four buttons shown below. Figure 7.1a shows an example of the wizard dialogs. Figure 7.1a Example of the Wizard Dialogs [Back] button : Opens the previous dialog. The data specified in the current dialog is discarded. [Next] button : Opens the next dialog. The data specified in the current dialog is saved. [Finish] button : The data set in all dialogs is reflected in the configuration file. [Cancel] button: Any specified data is discarded. The dialogs that appear when an existing configuration file is loaded or when the configurator is opened from the project window (called tabbed dialogs) have the two buttons shown below. Figure 7.1b shows an example of the tabbed dialogs. Figure 7.1b Example of the Tabbed Dialogs [OK] button : The current settings as edited with the definition dialogs are reflected in the configuration data. [Cancel] button: Clicking the [Cancel] button discards the changes. 180
199 MEMO 181
200 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Types of Dialog There are 13 types of dialog: System definition dialog System_1 definition dialog System_2 definition dialog Memory definition dialog System call definition dialog Task definition dialog Semaphore definition dialog Eventflag definition dialog Mailbox definition dialog Variable-size memorypool definition dialog Fixed-size memorypool definition dialog Vector definition dialog CPU setup dialog Types of Dialog System definition dialog (FR, 8L) Defines information related to the overall system. System_1 definition dialog (16) Defines system information. The information includes the number of cyclic activation handlers, number of alarm handlers, the CPU exception handler entry, the number of priority levels, whether to include the debugger, system call exception processing, and include names. System_2 definition dialog (16) Defines system information. The information includes kernel operation interrupt levels, the number of register banks, F 2 MC-16F-dedicated code output, wai_tsk function embedding, system clock handler settings, and the context switching method. Memory definition dialog (FR, 16, 8L) Defines information related to memory. System call definition dialog (FR) Selects system calls used. Task definition dialog (FR, 16, 8L) Defines information related to specific tasks. Semaphore definition dialog (FR, 16, 8L) Defines information related to specific semaphores. Eventflag definition dialog (FR, 16, 8L) Defines information related to specific eventflags. Mailbox definition dialog (FR, 16, 8L) Defines information related to specific mailboxes. Variable-size memorypool definition dialog (FR) Defines information related to specific variable-size memorypools. 182
201 7.1 Definition Dialog Organization Fixed-size memorypool definition dialog (FR, 16) Defines information related to specific fixed-size memorypools. Vector definition dialog (FR, 16, 8L) Defines interrupt handler and vector information. CPU setup dialog (16, 8L) Defines CPU information. 183
202 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR List of File Names A list of file names is used to edit file names. List of File Names If configuration data uses multiple file names, a list of file names, buttons for manipulating the list, and an edit box for inputting a file name are displayed. Figure shows an example of a list of file names in the system definition dialog. Figure Example of a List of File Names 184
203 7.1.3 File Selection 7.1 Definition Dialog Organization Input files are selected with a file selection dialog box. File Selection In the definition windows, the file selection dialog box is used to specify input or output files. When the [Browse] button of [Setting of include file] field in the system definition dialog box is clicked, the file selection dialog box opens. Figure shows an example of file selection dialog box. Once a file name is input in the [File name] field and the [OK] button is clicked, the file name that was input is regarded as having been specified. Only those files that match the wildcard specification in the [File list] field are displayed in the file list. When a file is selected from the file list by using the mouse, the name of that file is reflected in the [File name] field. Double-clicking a file in the file list causes that file to be regarded as having been specified immediately without the OK button being pressed. To change the wildcard specification in the [File list] field, select a new file type from the dropdown list box. Figure File selection dialog box display example 185
204 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Miscellaneous Lists An information list is used to edit multiple items of information. Miscellaneous Lists A list of multiple information items, buttons for manipulating the list, and edit boxes for entering the individual items are displayed. Figure shows an example of the mailbox definition dialog. Figure Example of a Miscellaneous List If the list is too long to fit vertically in the list box, a scroll bar is displayed. When a line is selected, the contents of the line are reflected in the edit boxes of the associated items. The [Add] button is used to add information specified for each item to the list box. The [Upd] button updates the selection in the list box the with information specified for each item. The [Del] button deletes the selection from the list box. When the last line in the list box is deleted, the preceding line is selected automatically. 186
205 MEMO 187
206 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.2 System Definition Dialog The system definition dialog defines the system-related information items listed below. Two types of system definition dialog are provided for the F 2 MC-16. Number of cyclic activation handlers (common) Number of alarm handlers (FR, 16) Exception handler entry name (FR) CPU exception handler entry name (16) Priority level (common) System call exception process (16) Kernel operation interrupt level (16) Number of register banks to be reserved (8L) F 2 MC-16F dedicated code output (16) Embedding of the wai_tsk function (16, 8L) System clock handler setting (8L) Context switching method (16) INCLUDE file (common) Specification of ret_int system call optimization (8L) System Definition Dialog Figures 7.2a, 7.2b, 7.2c, 7.2d, and 7.2e show examples of system definition dialogs. Figure 7.2a Example of the System Definition Dialog (FR) 188
207 7.2 System Definition Dialog Figure 7.2b Example of the System_1 Definition Dialog (16) 189
208 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Figure 7.2c Example of the System_2 Definition Dialog (16) Figure 7.2d Example of the Save and Restore Register Selection Dialog (16) 190
209 7.2 System Definition Dialog Figure 7.2e Example of the System Definition Dialog (8L) Setting items [common] [Cyclic Handler Counts] is specified with a numeric value. [Priority Level] is specified with a numeric value. [Include file Setting] specifies an include file name. For details on the operation of this list box, see Section 7.1.2, "List of File Names." For details of the definitions, see Sections 2.4.3, 2.5.3, and 2.6.3, "System Definitions." Setting items [8L] [Register Bank Secure Count] is specified with a numeric value. The specified value is passed to the linker. For [System Clock Handler Setting] and [wai_tsk embedding], make a selection as necessary. For [ret_int System Call Optimizing], make a selection as necessary. In the [Exception Handler] field, enter a label. When [OPTIMIZE] is selected, no entry in [Exception Handler] is allowed. (The default is NORMALIZE_2.) Setting items [16] [F 2 MC-16F Dedicated Code Output] is valid only when a 16F family device is selected as the CPU. [CPU Exception Handler Entry] specifies a label with a character string. [Entry] of [System Call Exception Process] specifies a label with a character string. For [Exception Execution Method] of [System Call Exception Process], select a method from 191
210 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR the drop-down list box as necessary. Select [WAI_TSK Embedding] as necessary. [Alarm Handler Count] is specified with a numeric value. When the check box of [System Clock Handler Embedding] of [System Clock Handler Setting] is checked, the [Return Method] button is displayed. Specify a desired return method from the drop-down list box as necessary. If [Escape and Return in Stack] is selected in [Context Switching Method], the [Register Selection] button is enabled. Clicking this button opens the [Escaped and Returned Register Selection] dialog. In this dialog, select the registers to be used, then click the [Close] button. The selected registers are set. [Kernel Operation Interrupt Level] is specified with a numeric value. Normally, 6 is specified. [Register Bank Secure Count] is specified with a numeric value. The specified value is passed to the linker. Setting items [FR] [Alarm Handler Count] is specified with a numeric value. [Exception Handler Entry] specifies a label with a character string, or specifies an address with a numeric value. Note: Exception handler If a CPU exception is generated without an exception handler having been defined, processing cannot continue properly. Definition Names Related to the System Definition Dialog [Common] [8L] CYC_HDR_NUMBER, PRIORITY_LEVEL, INCLUDE SCAL_EXC_ENTRY, SYS_CLOCK, REGISTER_BANK, WAI_TSK [16] ALM_HDR_NUMBER, CPU_EXTHDR_ENTRY, SYS_EXTHDR_ENTRY, ILM, CODE, SYS_CLOCK, CONTEXT_REGISTER, REGISTER_BANK, WAI_TSK [FR] ALM_HDR_NUMBER, EXC_HDR_ENTRY 192
211 MEMO 193
212 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.3 Memory Definition Dialog The memory definition dialog defines the following information items concerning memory: System stack size (common) Kernel code address (common) Kernel data address (common) Memory Definition Dialog Figures 7.3a, 7.3b, and 7.3c show examples of the memory definition dialogs. Figure 7.3a Memory Definition Dialog (FR) 194
213 7.3 Memory Definition Dialog Figure 7.3b Memory Definition Dialog (16) Figure 7.3c Memory Definition Dialog (8L) 195
214 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting item [common] [System Stack Size] is specified with a numeric value. The specification of [System stack] may be omitted. The default size is 0x40 for the 8L, 0x40 for the 16, and 0x400 for the FR. [Kernel Code Address] is specified with a numeric value. [Kernel Data Address] is specified with a numeric value. [OS Data Size] indicates the data area used by the operating system. [Variable Memorypool Size] (for the FR) indicates the total size of the memory pool management area and memory pool. [Fixed Memorypool Size] (for the FR,16 only) indicates the total size: the block size multiplied by the number of blocks. [Task Stack Size] indicates the total size of the task stack and common stack. The following four information items are also calculated and displayed according to the settings: OS data size Variable memory pool size (for the FR) Fixed memory pool size (for the FR,16 only) Task stack size For details, see Appendix B, "Kernel Code and Kernel Data." For details of the definitions, see Sections 2.4.4, 2.5.4, and 2.6.4, "Memory Definitions." Note: System stack size The system stack is used by the kernel and interrupt handler. Define the system stack size with a sufficient margin. If a system stack shortage occurs, the target system will not operate normally. Definition Names Related to the Memory Definition Dialog [Common] SYS_STK_SIZE [8L] KNL_ROM, KNL_RAM [16] KNL_ROM, KNL_RAM, MPL [FR] KNL_ROM, KNL_RAM, MPL 196
215 MEMO 197
216 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.4 System Call Definition Dialog The system call definition dialog is used to select system calls that are to be embedded in an absolute format object. By embedding only the necessary system calls, the size of the kernel code can be reduced. System Call Definition Dialog Figure 7.4a shows an example of the system call definition dialog. Figure 7.4b shows an example of the task management function dialog. Figure 7.4a Example of the System Call Definition Dialog (FR) Specifies a desired system call names displayed by selecting system call types from the dropdown list box. Click system call names to select whether or not to embed these system calls in the object." Figure 7.4b Example of the Task Management Function Definition Dialog (FR) 198 Clicking each button opens the system call dialog of the corresponding function. Click system call names to select whether or not to embed these system calls in the object.
217 7.4 System Call Definition Dialog Note: ret_int in the interrupt management function dialog and ret_tmr of the time management function are always selected. Note that in the evaluation version, regardless of the settings in this dialog, all system calls are always embedded in the object. For details about definition, see Section 2.4.5, System Call Definitions. Definition Name Related to the System Call Definition Dialog [FR] SYSTEM_CALL 199
218 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.5 Task Definition Dialog The task definition dialog defines the information items below. Task Definition Dialog Figures 7.5a, 7.5b, and 7.5c show examples of the task definition dialog. Figure 7.5a Example of the Task Definition Dialog (FR) 200
219 7.5 Task Definition Dialog Figure 7.5b Example of the Task Definition Dialog (16) 201
220 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Figure 7.5c Example of the Task Definition Dialog (8L) To make a task information addition or modification, first click the respective button. When the task detail definition dialog opens, the dialog can be used to make a definition or modification. If defines a common stack, clicking the [Common StackÅc] button of the dialog opens the common stack definition dialog. If the task is created by C source, can use to aim at the almost stack size with the bellow list displaying automatically analyzed stack size. This displaying stack size is including task context area. Note: Priority Level Ensure that each tasks activation priority level specify a higher value than a number of setting on [Priority Level]. Definition Names Related to the Task Definition Dialog [Common] TSK, COM_STACK 202
221 MEMO 203
222 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Task Detail Definition Dialog The task detail definition dialog defines the following task-related information items: Name (common) ID number (common) Entry (common) Activation priority (common) Stack (common) RP register (16/8L) DTB (16) ADB (16) DPR (16) CCR (16) Initial state (FR) Start code (FR) Extended information (FR) Time-out (FR) Task Detail Definition Dialog Figures 7.5.1a, 7.5.1b, and 7.5.1c show examples of the task detail definition dialog. Figure 7.5.1a Example of the Task Detail Definition Dialog (FR) 204
223 7.5 Task Definition Dialog Figure 7.5.1b Example of the Task Definition Dialog (16) Figure 7.5.1c Example of the Task Definition Dialog (8L) Setting items [common] [Name] specifies a character string for the task name. [Id Number] () specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. [Entry] specifies a character string for the label name. [Task Priority] (activation priority) specifies a numeric value. If this item is omitted, the priority level specified in the system definition dialog (system_1 definition for 16) is used as the minimum priority, and that value is displayed in the list box. [Stack] specifies a numeric value for the stack size, or specifies a common stack name with a character string or from the drop-down list box. Setting items [8L] [RP Register] specifies a numeric value. The default is 1. For details, see Section 2.6.5, "Task Definition." 205
224 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting items [16] [RP Register] specifies a numeric value. The default is 0. [DTB] specifies a numeric value. The default is 0. [ADB] specified a numeric value. The default is 0. [DPR] specifies a numeric value. The default is 0. [CCR] specifies a numeric value. The default is 0x40. (Set the I flag to 1, and the S flag to 0). For details, see Section 2.5.5, "Task Definition." Setting items [FR] [Task Status] (initial state) specifies a task state at system activation. [Start Code] specifies a numeric value. The default is 0. [Ex-Info] (extended information) specifies a numeric value or a character string that serves as a label name. The default is 0. [Time Out] specifies whether to use a system call with a time-out function. For details, see Section 2.4.6, "Task Definition." Note: Task stack size Define a task stack size with a sufficient margin. If an insufficient stack size is specified, the target system may malfunction. Definition Names Related to the Task Detail Definition Dialog [Common] TSK, COM_STACK 206
225 7.5.2 Common Stack Definition 7.5 Task Definition Dialog The common stack definition dialog defines a common stack. The size of memory can be suppressed by sharing the common stack among tasks without using the common stack at the same time. Common Stack Definition Figure shows an example of the common stack definition dialog. Figure Example of the Common Stack Definition Dialog (Common) Setting items [common] Clicking the [Common stack] button of the task definition dialog opens the common stack definition dialog. [Name] specifies a character string for the label name. [Size] specifies a numeric value for the stack size. For details of definition, see Section 2.4.7, Common Stack Definition, Section 2.5.6, Common Stack Definition, and Section 2.6.6, Common Stack Definition. Note: Common stack If multiple tasks sharing the same common stack are placed in a state (such as the ready and wait states) other than the dormant state, the target system malfunctions. Ensure that tasks operating simultaneously use a separate common stack or do not use a common stack. Definition Names Related to the Common Stack Definition Dialog [Common] TSK, COM_STACK 207
226 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.6 Semaphore Definition Dialog The semaphore definition dialog defines the following semaphore information items used in user programs: Name (common) Initial count (common) Extended information (FR) ID number (common) Maximum count value (FR) Semaphore Definition Dialog Figures 7.6a, 7.6b, and 7.6c show examples of the semaphore definition dialog. Figure 7.6a Example of the Semaphore Definition Dialog (FR) 208
227 7.6 Semaphore Definition Dialog Figure 7.6b Example of the Semaphore Definition Dialog (16) Figure 7.6c Example of the Semaphore Definition Dialog (8L) 209
228 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting items [common] [Name] specifies a character string for the semaphore name. [Id Number] specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. [Initial Count] specifies a numeric value for the system activation count value. The default is 1. Setting items [FR] [Max Count] (maximum count value) specifies a numeric value. The default is [Ex-Info] (extended information) specifies a numeric value or a character string that serves as a label name. The default is 0. For details of definition, see Section 2.4.8, Semaphore Definition, Section 2.5.7, Semaphore Definition, and Section 2.6.7, Semaphore Definition. Definition Names Related to the Semaphore Definition Dialog [Common] SEM 210
229 MEMO 211
230 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.7 EventFlag Definition Dialog The eventflag definition dialog defines the following eventflag information items used in user programs: Name (common) Initial pattern (16, FR) ID number (common) Extended information (FR) EventFlag Definition Dialog Figures 7.7a, 7.7b, and 7.7c show examples of the eventflag definition dialog. Figure 7.7a Example of the EventFlag Definition Dialog (FR) 212
231 7.7 EventFlag Definition Dialog Figure 7.7b Example of the EventFlag Definition Dialog (16) Figure 7.7c Example of the EventFlag Definition Dialog (8L) 213
232 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting items [common] [Name] specifies a character string for the event flag name. [Id Number] specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. Setting items [16] [Initial Pattern] specifies a numeric value. The default is 0. [Eventflag Type Definition] (bit length specification) specifies whether to use the 1-bit event flag function or the 16-bit event flag function. Setting items [FR] [Initial Pattern] specifies a numeric value. The default is 0. [Ex-Info] specifies a numeric value or a character string that servers as a label name. The default is 0. For details of definition, see Section 2.4.9, EventFlag Definition, Section 2.5.8, EventFlag Definition, and Section 2.6.8, EventFlag Definition. Definition Names Related to the EventFlag Definition Dialog [Common] FLG 214
233 MEMO 215
234 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.8 Mailbox Definition Dialog The mailbox definition dialog defines the following mailbox information items used in user programs: Name (common) Extended information (FR) ID number (common) Mailbox Definition Dialog Figures 7.8a, 7.8b, and 7.8c show examples of the mailbox definition dialog. Figure 7.8a Example of the Mailbox Definition Dialog (FR) 216
235 7.8 Mailbox Definition Dialog Figure 7.8b Example of the Mailbox Definition Dialog (16) Figure 7.8c Example of the Mailbox Definition Dialog (8L) 217
236 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting items [common] [Name] specifies a character string for the mailbox name. [Id Number] specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. Setting items [FR] [Ex-Info] (extended information) specifies a numeric value or character string that serves as a label name. The default is 0. For details of definition, see Section , Mailbox Definition, Section 2.5.9, Mailbox Definition, and Section 2.6.9, Mailbox Definition. Definition Names Related to the Mailbox Definition Dialog [Common] MBX 218
237 MEMO 219
238 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.9 Variable-Size MemoryPool Definition Dialog The variable-size memorypool definition dialog defines the following variable-size memorypool information items used in user programs: Name (FR) Memorypool size (FR) Extended information (FR) ID number (FR) Block size (FR) Variable-Size MemoryPool Definition Dialog Figure 7.9 shows an example of the variable-size memorypool definition dialog. Figure 7.9 Example of the Variable-Size MemoryPool Definition Dialog (FR) Setting items [FR] [Name] specifies a character string for the variable-size memory pool name. [Memorypool Size] specifies a numeric value. [Block Size] specifies a numeric value. [Id Number] specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. [Ex-Info] (extended information) specifies a numeric value or character string that serves as a label name. The default is 0. For details of definition, see Section , Variable-Size MemoryPool Definition. Definition Names Related to the Variable-Size MemoryPool Definition Dialog 220 [FR] MPL
239 MEMO 221
240 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.10 Fixed-Size MemoryPool Definition Dialog The fixed-size memorypool definition dialog defines the following fixed-size memorypool information items used in user programs: Name (FR, 16) ID number (FR, 16) Memorypool size (FR, 16) Number of blocks (FR, 16) Fixed-Size MemoryPool Definition Dialog Figures 7.10a and 7.10b show examples of the fixed-size memorypool definition dialog. Figure 7.10a Example of the Fixed-Size MemoryPool Definition Dialog (FR) 222
241 7.10 Fixed-Size MemoryPool Definition Dialog Figure 7.10b Example of the Fixed-Size MemoryPool Definition Dialog (16) Setting items [FR] [Name] specifies a character string for the fixed-size memory pool name. [Id Number] specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. [Block Count] (number of blocks) specifies a numeric value. [Block Size] specifies a numeric value. [Ex-Info] (extended information) specifies a numeric value or character string that serves as a label name. The default is 0. Setting items (16) [name] specifies a character string for the fixed-size memory pool name. [Id Number] (ID number) specifies a numeric value. If this item is omitted, an available number is assigned, and AUTO is displayed in the list box. [Block Size] specifies a numeric value. [Block Count] (number of blocks) specifies a numeric value. For details of definition, see Section , MemoryPool Definition, and Section , MemoryPool Definition. Definition Names Related to the Variable-Size MemoryPool Definition Dialog [16] MPL [FR] MPL 223
242 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.11 Vector Definition Dialog The vector definition dialog defines the following interrupt handler and vector information items used in user programs: Reset vector name (common) Initialization handler (16, 8L) Call vector setting (8L) Vector number (common) Entry (common) The system clock timer handler of the kernel is also defined using this dialog. Vector Definition Dialog Figures 7.11a, 7.11b, and 7.11c show examples of the vector definition dialog. Figure 7.11a Example of the Vector Definition Dialog (FR) 224
243 7.11 Vector Definition Dialog Figure 7.11b Example of the Vector Definition Dialog (16) Figure 7.11c Example of the Vector Definition Dialog (8L) 225
244 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR Setting items [common] [Number] specifies a numeric val/ue for the vector number. [Entry] specifies a character string for the label name. [Reset Vector Entry] specifies a character string for the reset vector entry name. Setting items [8L] [Initialization Handler Entry] specifies a character string for the initialization handler entry name. [Definition Name] specifies a desired number and entry name displayed by selecting call vector definition or interrupt handler definition from the drop-down list box. The list box displays vector numbers and their corresponding entry names. When a line is selected in the list box, the contents of the line are reflected as number and entry data in the edit box. Setting items [16] [Initialization Handler Entry] specifies a character string for the initialization handler entry name. For details of definition, see Section , Vector Definition, Section , Vector Definition, and Section , Vector Definition. Note: Interrupt handler (FR only) Interrupt handlers need to be defined for all interrupts generated on the target system. If an interrupt is generated, and no interrupt handler is defined for the interrupt, the usercreated system shutdown processing may be executed, and the target system may not continue processing normally. Definition Names Related to the Vector Definition Dialog [Common] EIT_ENTRY, RESET_ENTRY [8L] CALL_ENTRY, INIT_HDR_ENTRY [16] INIT_HDR_ENTRY 226
245 MEMO 227
246 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.12 CPU Setup Dialog The CPU setup dialog defines the following CPU information items used in user programs: Chip mode (16, 8L) Bus mode (16) Multiplex bus (16) Built-in RAM (16) CPU Setup Dialog Figures 7.12a and 7.12b show examples of the CPU setup dialog. Figure 7.12a Example of the CPU Setup Dialog (16) 228
247 7.12 CPU Setup Dialog Figure 7.12b Example of the CPU Setup Dialog (8L) [CPU Mode Setting] is used to make a desired selection for each of [Chip Mode], [Bus Mode], [Multiplex Bus], and [Inner RAM]. Depending on the CPU, some items may not be selectable, in which case those items are dimmed. Definition Names Related to the CPU Setup Dialog [8L] CPU [16] CPU 229
248 CHAPTER 7 DEFINITION DIALOGS IN THE WORKBENCH VERSION OF THE CONFIGURATOR 7.13 Debug Setting Dialog The Debug Seeing Dialog defines the following debug modules information items used in user programs: Kernel debug type (FR,16) Trace buffer size (FR,16) Debug module (FR,16) Debug Setting Dialog Figures 7.13a and 7.13b show examples of the debug setting dialog. Figure 7.13a Example of the Debug Definition Dialog (FR ) 230
249 7.13 Debug Setting Dialog Figure 7.13b Example of the Debug Setting Dialog (16) Setting items [FR, 16] [Kernel Debug Type] specifies a kernel debugging types of depending on debugging software. Standard Use the empty debugging hock module. Break Function Task dispatching break and system call break functions are allowed. Break & Trace (FR) Task dispatching break, system call break, and task trace without time stamp functions are allowed. REALOS Analyzer Ensure to select this If use the REALOS Analyzer. Other If use the other debugging software excepting Softune Workbench and REALOS Analyzer. In this case, select debugging module files by [Add] button. [Debug Module] specifies debugging module files that displays default file names of the place of installed Softune Workbench or REALOS. Click file names to select whether or not to embed these files int the system. If use the other placed files or another debugging software, add files and delete default displaying debugging module files. For details of the debugging module files, see "REALOS Analyzer Manual" 231
250 [Trace Buffer Size] specifies trace buffer size that is defined in assemble file as the symbol of "TRC_DATA_NUM". Note: If don t embed debugging module files in the system, select "Standard" of [Kernel Debug Type], or select "Other" and delete all selected files that entirely take debugging codes off. 232
251 CHAPTER 8 LIMITATIONS ON THE WORKBENCH VERSION OF THE CONFIGURATOR This chapter describes the limitations on the workbench version of the configurator. 8.1 Maximum Number of Definable Objects (FR) 233
252 CHAPTER 8 LIMITATIONS ON THE WORKBENCH VERSION OF THE CONFIGURATOR 8.1 Maximum Number of Definable Objects (FR) With FR, the number of objects that can be defined with the Workbench version of the configurator is limited. Maximum Number of Definable Objects (FR) The maximum number of definable entries of each type of object (task, semaphore, event flag, mailbox, and memory pool) is (More than 1024 entries can be set using the terminal version of the configurator.) 234
253 APPENDIX The appendixes contain notes on using the Softune REALOS configurator, information on kernel data allocation, configurator error messages, and a dialog list. Appendix A Notes on Using the Configurator Appendix B Kernel Code and Kernel Data Allocation Appendix C Configurator Error Messages Appendix D Dialog List 235
254 APPENDIX Appendix A Notes on Using the Configurator This appendix contains notes on using the configurator. Notes on Using the Embedded Version If the configurator file is modified, a kernel object file needs to be generated by specifying the -a option again. Notes on Using the Evaluation Version The definition statement SYSTEM_CALL cannot be used. If the definition statement is used, a warning message is displayed. Note: With the evaluation version, a kernel is generated so that all system calls can be used. Notes on Using the Configurator on Windows 95 or Windows NT The following statement is used to activate the configurator for the MS-DOS prompt on Windows 95 or Windows NT: frcfs [-V] [-XV] [-help] [-a] [-f configuration-file-name] When the configurator is used on the MS-DOS prompt screen, all options described in Section 4.1, Configurator Activation Commands, can be specified. Since the internal process activates the assembler and linker when the configurator is used on the MS-DOS prompt screen, define in the PATH environment variable the directory that contains the tools before using the configurator. 236
255 Appendix B Appendix B Kernel Code and Kernel Data Allocation Kernel Code and Kernel Data Allocation This appendix describes kernel codes and kernel data, and also describes the method of calculating the sizes of memory areas defined in KNL_ROM and KNL_RAM. Kernel Code and Kernel Data Usually, the kernel code section and kernel data section are automatically allocated in contiguous areas by specifying the KNL_ROM or KNL_RAM definition statement. The tables below list the kernel code sections and kernel data sections. Table B.a FR Family Kernel Code Section and Kernel Data Section Kernel code section Kernel data section inidata, oscode knldatal, sstack, knldata2, R_stk*, mplmem, mplctl, mpfmem Table B.b F 2 MC-16 Family Kernel Code Section and Kernel Data Section Kernel code section Kernel data section R97_TBL, T97_ILV, R97_CODE* R97_SSTK, T97_DATA, R97_STK*, R97_POOL* Table B.c F 2 MC-8L Family Kernel Code Section and Kernel Data Section Kernel code section Kernel data section R97_CODE, R97_ITB_SEG, R97_IST_SEG R97_SSTK, R97_*_DATA, R97_STK* Note: When KNL_ROM is not specified, all kernel code sections need to be allocated with USR_SECTION. When KNL_RAM is not specified, all kernel data sections need to be allocated with USR_SECTION. 237
256 APPENDIX Kernel code allocation In the memory area defined with the KNL_ROM definition statement, the configurator allocate code and initialized data items required for REALOS operation. Kernel code allocation on each CPU when a KNL_ROM definition is made is indicated below. FR kernel code allocation 0x KNL_ROM inidata oscode Kernel initialization data(*1) Operating system code size(*2) 0xFFFFFFFF *1: Kernel initialization data estimation inidata = (Number of tasks) + 16 (Number of semaphores) + 16 (Number of eventflags) + 12 (Number of mailboxes) + 28 (number of variable-size memorypools) + 24 (number of fixed-size memorypools) + 8 (Number of alarm handlers) + 8 (Number of cyclic activation handlers) *2: The operating system code size is about 3 K bytes to 9 K bytes. F 2 MC-16 kernel code allocation 0x R97_TBL KNL_ROM R97_ILV R97_CODE* 0xFFFFFF 238
257 F 2 MC-8L kernel code allocation Appendix B Kernel Code and Kernel Data Allocation 0x0000 KNL_ROM R97_CODE R97_ITB_SEG R97_IST_SEG 0xFFFF 239
258 APPENDIX Kernel code allocation In the memory area defined with the definition statement KNL_RAM, the configurator allocates various data items required for REALOS operation. Kernel data allocation in each CPU when a KNL_RAM definition is made is indicated below. FR kernel data allocation 0x KNL_RAM 0xFFFFFFFF knldata1 sstack knldata2 R_stknnnn mplmem mplctl empty Kernel management area(*1) Size defined for the system stack(*2) Fixed at 0x60 bytes Task stack(*3) Variable-size memorypool area(*4) Variable-size memorypool management area(*5) nnnn:task ID *1: Kernel management area (FR family) Table B.d indicates the formulas for calculating kernel management areas for the FR family. Table B.d Formulas for Calculating Kernel Management Areas for the FR Family (Unit: Bytes) Management area name Memory size used Task Semaphore Eventflag Mailbox Variable-size memorypool Fixed-size memorypool Alarm handler Cyclic activation handler x (priority level) + 44 x (number of tasks) 16 x (number of semaphores) 16 x (number of eventflags) 20 x (number of mailboxes) 20 x (number of variable-size memorypools) 24 x (number of fixed-size memorypools) 28 (number of alarm handlers) 28 x (number of cyclic activation handlers) *2: Finding a system stack size The system stack size depends heavily on the user system status (methods of using interrupts and programming interrupt handlers). The user should therefore set a system stack size that matches the user's system, ignoring the default. 240
259 Appendix B Kernel Code and Kernel Data Allocation The system stack area is used for user interrupt handler processing, kernel system call processing, and system clock processing. The size used by each type of processing is as follows: (a) Kernel system call processing: Approx. 100 bytes (b) User interrupt handler processing: Size used by the user interrupt handlers Note:Add (a) when a handler issues a system call. (c) System clock processing: Approx. 80 bytes + Size used by the user timer handler Note:Add (a) when a handler issues a system call. However, the greatest value among (a), (b), and (c) should not be simply selected as a system stack size. Since these types of processing may be nested, consider this before determining a system stack size. For example, suppose that a task issues a system call, and that an interrupt is generated while the kernel is executing system call processing. Further, suppose that the user interrupt handler is activated, then issues another system call. In such a case, the required size is (a) + (b). Consequently, a system stack size can be found as follows: System stack = (a) + ((b) x (maximum level of interrupt nesting)) + (c) *3 Formula for calculating task stack sizes The total of task stack sizes is sum of the stack sizes of tasks not using common stacks + sum of the sizes of common stacks defined. (Common stacks not in use are not included.) *4 Variable-size memorypool area, fixed-size memorypool area Total of variable-size memorypool sizes or fixed-size memorypool sizes *5 Variable-size memorypool management area Memorypool name Memorypool size Block size Number of blocks mpl_1 M1 m1 k1 mpl_2 M2 m2 k2 : : :: mpl_n Mn mn kn (However, kx = Mx mx) When there are n variable-size memorypools as indicated above, the size (T) of a variable-size memorypool management area is T = ((K1 + 1) + (K2 + 1) (Kn + 1))
260 APPENDIX F 2 MC-16 kernel data allocation 0x KNL_RAM R97_SSTK R97_DATA R97_STK* R97_POOL*... Kernel management area 0xFFFFFF Table B-e indicates the formulas for calculating kernel management areas for the F 2 MC-16 family. Table B.e Formulas for Calculating Kernel Management Areas for the F 2 MC-16 Family (Unit: Bytes) Management area name Memory size used Task (number of tasks) + 4 x (priority level) Evenflag(*1) 1 bit ((4 + 1) bits) x (number of eventflags) 16 bits 6 x (number of eventflags) Semaphore Mailbox Variable-size memorypool When wai_tsk or 16-bit eventflag is incorporated 5 x (number of semaphores) 6 x (number of mailboxes) 8 x (number of memory pools) 2 x (number of tasks) Time management Common 2 (when system clock or timer handler is incorporated) System clock 6 (when system clock is incorporated) Timer(*2) 4 Cyclic activation handler Alarm handler ((12 + 1) bits) x (number of handlers) x (number of handlers) *1: Select 1 bit or 16 bits according to the eventflag management method. *2: To be added when a cyclic activation handler or wai_tsk is incorporated Note: If the number of bits is less than a byte, the value is rounded upward to a byte. When the number of objects of each type is 0, or when the number of handlers is 0, 0 bytes should be used, regardless of the formula. 242
261 F 2 MC-8L kernel data allocation Appendix B Kernel Code and Kernel Data Allocation 0x0000 KNL_RAM R97_SSTK R97_*_DATA R97_STK*... Kernel management area 0xFFFF Table B-f indicates the formulas for calculating kernel management areas for the F 2 MC-8L family. Table B.f Formulas for Calculating Kernel Management Areas for the F 2 MC-8L Family (Unit: Bytes) Management area name Memory size used Task 14 + (9 to 11)(*1) x (number of tasks) + 4 x (priority level) Evenflag Semaphore Mailbox System clock Cyclic activation handler When wai_tsk is incorporated ((4 + 1) bits) x (number of eventflags) 5 x (number of semaphores) 4 x (number of mailboxes) 4 (when system clock is incorporated) 4 + ((8 + 1) bits) x (number of cyclic activation handlers) 4 (0 bytes when cyclic activation handler is incorporated) *1: Usually, 9 bytes are used. When wai_tsk is incorporated, 11 bytes are used. Note: If the number of bits is less than a byte, the value is rounded upward to a byte. When the number of objects of each type is 0, or when the number of handlers is 0, 0 bytes should be used, regardless of the formula. 243
262 APPENDIX Examples of Memory Size Calculations Example of memory size calculation (FR family) Table B.g shows an example of kernel and task memory size calculation for the FR family. Table B.g Kernel and Task Memory Size Calculation (FR Family) Example of kernel memory size calculation Subtotal Setting condition Fixed value 204 bytes 1224 bytes Priority level 8 x 8 64 bytes Number of tasks 16 pcs. x bytes Number of eventflags 8 pcs. x bytes Number of mailboxes 2 pcs. x bytes Number of cyclic activation handlers 3 pcs. x bytes When system clock is used When system call is issued within handler System stack Kernel system call processing (fixed value) 100 bytes 380 bytes Size used by user interrupt handlers When system call is issued within handler (fixed value) When system clock processing is incorporated into system 100 bytes 100 bytes 80 bytes System stack = User stack Operating system area (fixed) 96 bytes 3136 bytes Stack used by user 100 bytes User stack = ( ) x 16 (number of tasks) Total 4740 bytes 244
263 Appendix B Kernel Code and Kernel Data Allocation Example of memory size calculation (F 2 MC-16 family) Table B.h shows an example of kernel and task memory size calculation for the F 2 MC-16 family. Table B.h Kernel and Task Memory Size Calculation (F 2 MC-16 Family) Example of kernel memory size calculation Subtotal Setting condition Number of cyclic activation handlers 4 each 358 bytes Priority level 6 levels System clock Number of tasks 16 Number of eventflags 8 Number of mailboxes 2 System stack Register bank area Suppose that an area of 14 bytes is used for one multilevel interrupt, and that a system call can be issued from the area. Then, 14 bytes are required. An additional area is required when a user stack is used within a handler. Stack used within a handler: 8 bytes System stack area = 14 used when system calls are issued) x 4 levels + (14 used within stack handler at handler activation) x 4 levels One bank is used for the kernel. One bank is used for the handler. One bank is used for each task. Register bank area = (1 kernel + 1 handler + number of tasks) x bytes 288 bytes User stack area Operating system control area bytes User stack 32 (Operating system control area + user stack) x 16 stacks Total 1558 bytes 245
264 APPENDIX Example of memory size calculation (F 2 MC-8L family) Table B.i shows an example of kernel and task memory size calculation for the F 2 MC-8L family. Table B.i Kernel and Task Memory Size Calculation (F 2 MC-8L Family) Example of kernel memory size calculation Subtotal Setting condition Number of cyclic activation handlers bytes Number of eventflags 3 Number of mailboxes 3 Number of cyclic activation handlers 3 Priority level 4 levels System stack Register bank area System clock Suppose that an area of 12 bytes (PC, PS, A, T, IX, and EP) is used for one multilevel interrupt, and that a system call can be issued from the areas. Then, 14 bytes are required. Because there are two levels, a system stack area of 52 bytes is required in total. An additional area is required when a user stack is used within a handler. Stack used within a handler: 8 bytes Interrupt: 2 levels System stack area = ((handler activation stack (12) + stack used for system calls (14)) x 2 levels + stack used within handler (8) One bank is used for kernel. One bank is used for handler. One bank is used for each task (4 banks). Register bank area = (1 kernel + 1 handler + number of tasks) x 8 60 bytes 48 bytes User stack area User stack bytes When multilevel interrupts are accepted (One task must not be interrupted.) 60 (User stack + interrupt stack) x 3 tasks + user stack Total 480 bytes 246
265 Task Stack [Task stack session] Appendix B Kernel Code and Kernel Data Allocation The configurator creates task stack sessions in the temporary file for each task ID using the following rules: [FR] Task stack section name: R_stkXXXX Symbol name: R_XXXXstk [16, 8L] XXXX indicates a four-digit hexadecimal character string. Task stack section name: R97_STKXX Symbol name: r97_xxstk XX indicates a two-digit hexadecimal character string. These names can be used to initialize task stack regions. Task stack sections are output to R_wdata.asm for the FR and to R97_data.asm for the F 2 MC_16. [Example of output for the FR] The following is output when the task ID is decimal 10 and the size of stack region is 0x400: R_wdata.asm DATA_SECTION R_000Astk SECTION_END R_stk000A,4.export R_000Astk.res.b 0x
266 APPENDIX [Task stack size] The task stack size is defined using rules similar to those for the task stack section name. [FR] Task stack size: R_TSKSKXXXX XXXX indicates a four-digit hexadecimal character string. [16, 8L] Task stack size: R97_STKXX XX indicates a two-hexadecimal character string. Task stack sections are output to R_id.asm for the FR and R97_id.asm for the F 2 MC_16. [Example of output for the FR] The following is output when the task ID is 1 and the size of stack region is 0x500: R_id.asm.export R_TSKSK0001 R_TSKSK0001.equ 0x
267 Appendix C Configurator Error Messages Appendix C Configurator Error Messages This appendix describes the levels and display format of messages that are output during configuration. Configurator Error Message Levels The error messages output by the configurator when configuration is executed are classified into three levels on the basis of severity. Warning This type of message is less serious than an error, and the results of output can be used with almost no problem being caused. In some cases, however, processing not intended by the user may be performed. After checking a warning message, determine whether the results of output are usable. Error This type of message allows processing to be continued, but configuration is not executed. The cause of an error must be corrected, then configuration must be reexecuted. Usually, errors occur when a file is read. Fatal error This type of message indicates an error that prevents processing from continuing. A fatal error may be caused by an incorrect specification by the user or by execution environment problem. In addition, error messages are output by the assembler and linker executed within the configurator. For these messages, see the Softune Assembler Manual and the Softune Linkage Kit Manual. 249
268 APPENDIX Display Format of Configurator Error Messages Error messages are output in the following format. *** file name (line number) XnnnT: message text (auxiliary-message) Field file-name (line-number) X nnnn T message-text auxiliarymessage Description Configuration file name and line number that encountered the error. This information is output if an error occurs when a configuration file is read. An error level is indicated using one of the following three characters: W: Warning message E: Error F: Fatal error Error number. Error numbers and error levels are related as follows: 1000 to 1999: W 4000 to 4999: E 9000 to 9999: F The tool ID is represented by the following letter: M: Configurator Error message text (The user can choose between Japanese and English.) More detailed information about the error. Information such as the symbol name that caused the error is displayed. This information may be included in the error message text. Note: An error may occur when the assembler or linker has been activated by the configurator. In this case, a tool ID of A or L may be output. For details of this type of error, see the Softune Assembler Manual and the Softune Linkage Kit Manual. 250
269 Warning Message Appendix C Configurator Error Messages W1001M Can not use definition name on evaluation version The definition name identified by definition-name cannot be used with the evaluation version. This error occurs only when the evaluation version is used. 251
270 APPENDIX Error Messages E4024M Illegal character (parameter name) The parameter identified by parameter-name includes an unusable character. This error occurs when, for example, a nonnumeric character is specified in a parameter where a numeric value must be specified, or a numeric value is specified in a parameter where a label must be specified. E4026M Specified value is out of range (value) A value within the value range indicated by value is specifiable. This error occurs when, for example, a value greater than is specified as an object ID. E4100M Nest level exceeds limit (MAX nesting level) The INCLUDE file nesting level exceeded the level indicated by nesting-level. E4110M Unknown define name (definition name) The definition name indicated by definition-name cannot be used. This error occurs when, for example, an unsupported definition name is used. 252
271 Appendix C Configurator Error Messages E4111M Too long line (MAX value char) A line must not be longer than the value indicated by value. Correct the line so that it is not longer than the value indicated by value. E4120M parameter name is too long The parameter identified by parameter-name is too long. E4121M Too many definition name (MAX value) The number of definitions identified by definition-name must not exceed value. This error occurs when, for example, an attempt is made to define more than tasks. E4123M Too many Parameters (parameter) The parameter identified by parameter and subsequent parameters are not required. 253
272 APPENDIX E4130M Multiple definition (definition name) A definition statement that must not specified more than once was specified more than once. This error occurs when, for example, a CPU definition is made more than once, or the same common stack name, or task, semaphore, eventflag, mailbox, or memorypool ID is specified more than once. E4131M Parameter not defined (parameter name) A parameter that must always be specified is was not specified. The parameter identified by parameter-name must not be omitted. E4132M Illegal parameter (parameter) A parameter that cannot be specified was specified. This error mainly occurs when, for example, a character string that cannot be selected is specified in a selection item. E4133M Symbol is already defined (symbol name) A symbol that is already defined was defined again. This error occurs when, for example, an attempt is made to define a duplicate task, semaphore, eventflag, mailbox, or memorypool name. 254
273 Appendix C Configurator Error Messages E4136M Illegal size or address (value) The size or address indicated by value is incorrect. When specifying a size or address, specify a multiple of 4 (or, for the last address, a multiple of 4 less 1). E4140M Isemcnt is bigger than maxcnt (MAX value) A value greater than the maximum allowable value was specified for the initial semaphore count. Decrease the initial count, or increase the maximum allowable value. E4141M Blksiz is bigger than mplsiz (MAX size) A value greater than the memorypool size was specified for the memorypool block size. Decrease the block size, or increase the memorypool size. 255
274 APPENDIX Fatal Error Messages F9000M Environment variable not found (environment variable name) The environmental variable identified by environmental-variable-name is not defined. F9001M Insufficient memory Memory for executing a program is insufficient. The program may be made executable by the following: Decrease the number of tasks, the number of semaphores, the number of eventflags, the number of mailboxes, and the number of memory pools. Shorten task names, semaphore names, eventflag names, mailbox names, memorypool names, and task entry symbol names. Specify no task extension information, semaphore extension information, eventflag extension information, mailbox extension information, and memorypool extension information. If memory is still insufficient, increase the amount of memory installed on the personal computer when using the personal computer version, or use the workstation version. When using the workstation version, contact the system administrator and increase the system memory space. F9002M Not configurated Configuration was not executed. This error mainly occurs when configuration fails due to a configuration file read error. 256
275 Appendix C Configurator Error Messages F9003M Kernel source file not found The kernel source file is not stored under the predetermined directory ($RTOS\knl). This error occurs when the evaluation version is used and configuration is executed with specifying the -a option. F9011M Input file is not found (file name) The specified input file cannot be found. F9016M File read error (file name) Read permission has not been granted for the file identified by file-name, or there is a hardware problem. F9017M File write error (file name) The disk where the file identified by file-name is was to be written is full. Create a free space on the disk, then reexecute configuration. This error also occurs when there is a file or directory that has the same name and write permission has not been granted. 257
276 APPENDIX F9022M Unknown option name (option) A nonexistent option was specified. F9023M Illegal option parameter (parameter) The specification of the parameter identified by parameter is incorrect. F9030M Missing input file name No file name was specified for the -f option. F9801M definition name is not defined The definition identified by definition-name was not made. This error occurs when a definition statement that must not be omitted is not specified. F9802M definition name (name) is not defined name is not defined in the definition identified by definition-name. This error occurs mainly when a common stack is specified in a task definition without a task common stack being defined. 258
277 Appendix C Configurator Error Messages F9803M definition name (ID: number) is not defined The definition data corresponding to definition-name(id: number) is not defined. This error occurs mainly when successive ID numbers are not used in task, semaphore, eventflag, mailbox, or memorypool definitions. F9804M PRIORITY_LEVEL is higher than tsk_priority (more than priority level) A priority lower than the priority level specified in the definition statement PRIORITY_LEVEL was specified as a task activation priority. For a task activation priority, specify a priority not lower than the priority level specified in the definition statement PRIORITY_LEVEL. F9805M EIT vector No. vector number is system reserve The EIT vector identified by vector-number is reserved for the system. This error occurs when a CPU definition statement is omitted. This error also occurs when an MB91V100 or MB91103 is specified, and an EIT vector other than vector numbers 16 to 62 and 65 to 255 is defined. F9897M Error in assembler (file name) An error occurred with the assembler. This error occurs mainly when a character that is not allowed is specified in a task entry or extended information. 259
278 APPENDIX F9898M Error in linker An error occurred with the linker. Correct the cause of the error according to the map file. F9899M tool name is not found The directory where the assembler and linker are stored cannot be found using the PATH environmental variable. Define in the PATH environmental variable the directory where the assembler and linker are stored. F9990M File I/O error (file name, identification information) An error occurred during file input-output. F9993M Can not create directory (directory name) The directory identified by directory-name cannot be created. The disk may have no free space, or there may be a file or directory that has the same name and write permission has not been granted. 260
279 Appendix C Configurator Error Messages F9994M Can not create file (file name) The file identified by file-name cannot be created. The disk may have no free space, or there may be a file or directory that has the same name and write permission has not been granted. F9995M Can not close file (file name) The file identified by file-name cannot be closed. The disk may have no free space. F9996M Can not open file (file name) The file identified by file-name cannot be opened. The disk may have no free space, or there may be a file or directory that has the same name and write permission has not been granted. F9997M Error message not found The message file (frcfs.msg) used by the configurator may have been destroyed. Reinstall Softune REALOS. If this error still occurs after reinstallation, contact your Fujitsu representative immediately. 261
280 APPENDIX F9998M Can not open message file (file name) The message file used by the configurator cannot be opened. Store frcfs.msg under the directory ($RTOS\syslib). F9999M Internal error (identification information) When this error occurs, contact your Fujitsu representative immediately. 262
281 Appendix D Dialog List Appendix D Dialog List This appendix describes the following dialogs output when a dangerous operation or incorrect operation is perfor med: Warning dialog Error dialog Warning Dialog The warning dialog is output when setting data may be lost. Figure D.a shows an example of warning dialog output. Figure D.a Example of the Warning Dialog W1100M: Target MCU is different. New project: MB91101 Configuration file:mb91107 Target MCU set by a new project is made effective. The target MCU differs from the MCU (CPU) set in the configuration file. Target MCU set by a new project becomes effective. W1101M The relocatable object file and library file in the loaded configuration file are not registered. Register the members. When an existing configuration file is read, the relocatable object file and library file set in the configuration file are not registered. Open a dialog by first selecting [Project] and then [Member Setting] in Softune Workbench, then setting the members. 263
282 APPENDIX W1102M: Enter a file name. When an existing configuration file is read, this message is output if you click the [OK] button without setting the file name in the file input edit box. Set the configuration file. W1103M: Section allocation has changed. Okay to proceed with initialization? This message is output if, after a kernel code address or kernel data address has been set, another kernel code address or kernel data address is set. When you click the [OK] button, the new setting is reflected in Softune Workbench. W1104M: Set a ROM or RAM area by setting the link option after selecting [Project] then [Tool Option Setting]. This message is output when you click [Complete] in the configurator setting dialog after creating a new configuration file. From the tool option setting dialog of the project menu in Sotfune Workbench, select the linker tab. Then, select [Allocation or Linkage] from the category, and set a ROM or RAM area. 264
283 Error Dialog The error dialog is output, for example, for an incorrect specification. Figure D.b shows an example of error dialog output. Appendix D Dialog List Figure D.b Example of the Error Dialog E4200M: The stack name is registered in the task definition. When a stack name is set in the task definition dialog, this message is output if an attempt is made to delete or change the stack name in the common stack definition dialog. E4201M: Execution is disabled because memory is insufficient. Close unnecessary Windows applications, then reexecute. This message is output if a settings attempt is made when memory is insufficient. Close unnecessary Windows applications, then retry. E4202M: A set MB number is invalid. The target MCU set in the new project is made effective. This message is output when the MCU (CPU) set in the existing configuration file is not registered as a target MCU. 265
284 INDEX INDEX A absolute object name ABSOLUTE_FILE ALM_HDR_NUMBER B button C CALL_ENTRY CODE common stack definition... 26, 46, 64, 207 common stack definition dialog COM_STACK configuration...6, 14 configuration data... 4, 13, 17, 37 configuration definition statement configuration file configurator... 7, 10, 11, 12, 158, 164, 165, 170 configurator startup command CONTEXT_REGISTER CPU... 76, 78 CPU definition... 18, 38, 56 CPU setup dialog , 229 CPU_EXTHDR_ENTRY CYC_HDR_NUMBER D Debug Setting Dialog definition name related to the CPU setup dialog. 229 definition name related to the evenflag definition dialog 214 definition name related to the mailbox definition dialog definition name related to the memory definition dialog definition name related to the semaphore definition dialog definition name related to the system call definition dialog 199 definition name related to the system definition dialog definition name related to the task definition dialog 202 definition name related to the variable-size memorypool definition dialog...220, 223 definition name related to the vector definition dialog definition names related to the common stack definition dialog definition names related to the task detail definition dialog 206 definition of configuration data definition statement definition statement format dialog E EIT_ENTRY entry eventflag... 48, 66 eventflag definition... 30, 48, 66, 129 eventflag definition dialog , 214 eventflag type exception handler name EXC_HDR_ENTRY F F2MC-16F dedicated code file name file selection fixed-size memorypool definition... 34, 52 fixed-size memorypool definition dialog FLG...129, 130 FLG_BIT FLG_PATTERN I ILM...95 INCLUDE...94 INIT_HDR_ENTRY initial pattern initialization handler interrupt level, allowable K kernel KNL_RAM
285 KNL_ROM L library name... 39, 57 LIBRARY_FILE linkage definition... 19, 39, 57 List M mailbox definition... 31, 50, 67 mailbox definition dialog , 218 map file output... 39, 57 MAP_FILE MBX memory... 42, 60 memory definition... 21, 42, 60 memory definition dialog , 196 monitor debugger MPF MPL , 137 O object object file P PRIORITY_LEVEL project SYS_EXTHDR_ENTRY SYS_STK_SIZE system call definition system call definition dialog , 199 system call exception system definition... 20, 40, 58 system definition dialog , 192 SYSTEM_CALL T task definition... 24, 44, 62 task definition dialog , 202 task detail definition dialog , 206 TSK , 114, 117 U USR_SECTION V variable-size memorypool definition variable-size memorypool definition dialog. 220, 223 variable-sizememorypool definition dialog vector definition... 36, 54, 68 vector definition dialog , 226 W wai_tsk R RAM REGISTER_BANK relocatable object name RELOCATE_FILE RESET_ENTRY ROM S SCAL_EXC_ENTRY SEM , 126 semaphore semaphore definition... 28, 47, 65 semaphore definition dialog , 210 SEM_ICNT SYS_CLOCK
286
287 CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL FR FAMILY F²MC FAMILY IN CONFORMANCE WITH µitron SPECIFICATIONS SOFTUNE REALOS CONFIGURATOR MANUAL October 1999 the second edition Published FUJITSU LIMITED Electronic Devices Edited Technical Communication Dept.
288
289
290 FUJITSU SEMICONDUCTOR FR FAMILY F²MC FAMILY IN CONFORMANCE WITH µitron 3.0SPECIFICATIONS SOFTUNE REALOS CONFIGURATOR MANUAL
Quick Start Tutorial. Using the TASKING* Software Development Tools with the Intel 8x930 Family Evaluation Board
Quick Start Tutorial Using the TASKING* Software Development Tools with the Intel 8x930 Family Evaluation Board This explains how to use the TASKING Microsoft* Windows*-based software development tools
SKP16C62P Tutorial 1 Software Development Process using HEW. Renesas Technology America Inc.
SKP16C62P Tutorial 1 Software Development Process using HEW Renesas Technology America Inc. 1 Overview The following tutorial is a brief introduction on how to develop and debug programs using HEW (Highperformance
Remote Access Server - Dial-Out User s Guide
Remote Access Server - Dial-Out User s Guide 95-2345-05 Copyrights IBM is the registered trademark of International Business Machines Corporation. Microsoft, MS-DOS and Windows are registered trademarks
Chapter 12. Development Tools for Microcontroller Applications
Chapter 12 Development Tools for Microcontroller Applications Lesson 01 Software Development Process and Development Tools Step 1: Development Phases Analysis Design Implementation Phase 1 Phase 2 Phase
Software License Registration Guide
Software License Registration Guide When you have purchased new software Chapter 2 Authenticating a License When you would like to use the software on a different PC Chapter 3 Transferring a License to
Mitsubishi Electric Q Series PLC Ladder Monitor. Operation Manual
Mitsubishi Electric Q Series PLC Ladder Monitor Operation Manual Preface Thank you for purchasing Pro-face's PLC Ladder Monitor Add-on Kit for the Mitsubishi Electric Q Series PLC. This manual ("Mitsubishi
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This
The following document contains information on Cypress products.
The following document contains information on Cypress products. 32-BIT MICROCONTROLLER MB9B100A/MB9B300A/MB9B400A/MB9B500A Series FM3 family inverter solution GUI User Manual TM ARM and Cortex-M3 are
Manuals for This Product
Installation Guide Manuals for This Product Manuals for this product have the following structure. Read the manual according to your purpose for using this product. Disc Guides with this symbol are PDF
PRIMEQUEST Integration
C122-E062-01EN PRIMEQUEST Integration for Microsoft Operations Manager FUJITSU LIMITED Preface Purpose This manual explains the MOM management pack (PRIMEQUEST Server Agent MOM Connector), a function
The following document contains information on Cypress products.
The following document contains information on Cypress products. Colophon The products described in this document are designed, developed and manufactured as contemplated for general use, including without
Job Management Partner 1/File Transmission Server/FTP Description, Reference and Operator's Guide
For Windows Systems Job Management Partner 1 Version 10 Job Management Partner 1/File Transmission Server/FTP Description, Reference and Operator's Guide 3021-3-334-10(E) Notices Relevant program products
Business Intelligence Tutorial
IBM DB2 Universal Database Business Intelligence Tutorial Version 7 IBM DB2 Universal Database Business Intelligence Tutorial Version 7 Before using this information and the product it supports, be sure
TIBCO Hawk SNMP Adapter Installation
TIBCO Hawk SNMP Adapter Installation Software Release 4.9.0 November 2012 Two-Second Advantage Important Information SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR
Pro-Watch Software Suite Installation Guide. 2013 Honeywell Release 4.1
Pro-Watch Software Suite Release 4.1 Installation Guide Document 7-901073V2 Pro-Watch Software Suite Installation Guide 2013 Honeywell Release 4.1 Copyright 2013 Honeywell. All rights reserved. Pro-Watch
Virtual CD v10. Network Management Server Manual. H+H Software GmbH
Virtual CD v10 Network Management Server Manual H+H Software GmbH Table of Contents Table of Contents Introduction 1 Legal Notices... 2 What Virtual CD NMS can do for you... 3 New Features in Virtual
Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks
Loading the block library 1 Deleting program block Main [OB1] 2 TIA Portal SIMATIC Getting Started Copying program blocks 3 Cyclic interrupt OB 4 Copying tag tables 5 Compiling a project 6 Load project
SCADAPack E ISaGRAF 3 User Manual
SCADAPack E ISaGRAF 3 User Manual 2 SCADAPack E ISaGRAF 3 User Manual Table of Contents Part I ISaGRAF 3 User Manual 3 1 Technical... Support 3 2 Safety... Information 4 3 Preface... 6 4 Overview... 8
GAUSS 9.0. Quick-Start Guide
GAUSS TM 9.0 Quick-Start Guide Information in this document is subject to change without notice and does not represent a commitment on the part of Aptech Systems, Inc. The software described in this document
Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management
Administration guide Host software WinCCU Installation Complete gas volume and energy data management Contents 1 Introduction... 1 Safety first... 1 Warning... 1 Typographic conventions... 1 Product versioning...
Software development and debugging for NXP ARM7 MCUs
THE MINISTRY of EDUCATION and SCIENCE of RUSSIAN FEDERATION SAMARA STATE AEROSPACE UNIVERSITY Software development and debugging for NXP ARM7 MCUs Learner s guide SAMARA 2011 2 Compilers: Kudryavtsev Ilya
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
DiskPulse DISK CHANGE MONITOR
DiskPulse DISK CHANGE MONITOR User Manual Version 7.9 Oct 2015 www.diskpulse.com [email protected] 1 1 DiskPulse Overview...3 2 DiskPulse Product Versions...5 3 Using Desktop Product Version...6 3.1 Product
Block 3 Size 0 KB 0 KB 16KB 32KB. Start Address N/A N/A F4000H F0000H. Start Address FA000H F8000H F8000H F8000H. Block 2 Size 8KB 16KB 16KB 16KB
APPLICATION NOTE M16C/26 1.0 Abstract The following article describes using a synchronous serial port and the FoUSB (Flash-over-USB ) Programmer application to program the user flash memory of the M16C/26
CodeWarrior Development Studio for Freescale S12(X) Microcontrollers Quick Start
CodeWarrior Development Studio for Freescale S12(X) Microcontrollers Quick Start SYSTEM REQUIREMENTS Hardware Operating System Disk Space PC with 1 GHz Intel Pentum -compatible processor 512 MB of RAM
Embedded Software development Process and Tools:
Embedded Software development Process and Tools: Lesson-2 Integrated Development Environment (IDE) 1 1. IDE 2 Consists of Simulators editors, compilers, assemblers, etc., IDE 3 emulators logic analyzers
Adapting the PowerPC 403 ROM Monitor Software for a 512Kb Flash Device
Adapting the PowerPC 403 ROM Monitor Software for a 512Kb Flash Device IBM Microelectronics Dept D95/Bldg 060 3039 Cornwallis Road Research Triangle Park, NC 27709 Version: 1 December 15, 1997 Abstract
Hitachi Data Ingestor
Hitachi Data Ingestor Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-90HDI009-14 2010-2015 Hitachi, Ltd. All rights reserved. No part of this
How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment?
Author Janice Hong Version 1.0.0 Date Mar. 2014 Page 1/56 How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment? Application Note The 32-bit operating system
StruxureWare Power Monitoring 7.0.1
StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions
NETWRIX EVENT LOG MANAGER
NETWRIX EVENT LOG MANAGER QUICK-START GUIDE FOR THE ENTERPRISE EDITION Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not
(Cat. No. 6008-SI) Product Data
(Cat. No. 6008-SI) Product Data 1 Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying
Expedite for Windows Software Development Kit Programming Guide
GXS EDI Services Expedite for Windows Software Development Kit Programming Guide Version 6 Release 2 GC34-3285-02 Fifth Edition (November 2005) This edition replaces the Version 6.1 edition. Copyright
Freescale Semiconductor, I
nc. Application Note 6/2002 8-Bit Software Development Kit By Jiri Ryba Introduction 8-Bit SDK Overview This application note describes the features and advantages of the 8-bit SDK (software development
Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis
Autodesk Ecotect Analysis 2011 Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis This document describes how to install and activate Autodesk Ecotect Analysis 2011 software
Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2
Introduction 1 Web application basics 2 SIMATIC Information Server V8.0 Update 1 System Manual Office add-ins basics 3 Time specifications 4 Report templates 5 Working with the Web application 6 Working
Microsoft Access 2010 Part 1: Introduction to Access
CALIFORNIA STATE UNIVERSITY, LOS ANGELES INFORMATION TECHNOLOGY SERVICES Microsoft Access 2010 Part 1: Introduction to Access Fall 2014, Version 1.2 Table of Contents Introduction...3 Starting Access...3
Avaya Network Configuration Manager User Guide
Avaya Network Configuration Manager User Guide May 2004 Avaya Network Configuration Manager User Guide Copyright Avaya Inc. 2004 ALL RIGHTS RESERVED The products, specifications, and other technical information
PC Transfer Tool Operation Manual
PC Transfer Tool Operation Manual Digital Electronics Corporation PREFACE Thank you for purchasing PC Transfer Tool. PC Transfer Tool allows you to perform maintenance operations easily, (uploading to
SQLBase. Starter Guide 20-2905-1004
SQLBase Starter Guide 20-2905-1004 Trademarks Centura, Centura net.db, Centura Ranger, the Centura logo, Centura Web Developer, Gupta, the Gupta logo, Gupta Powered, the Gupta Powered logo, Fast Facts,
Oracle Endeca Server. Cluster Guide. Version 7.5.1.1 May 2013
Oracle Endeca Server Cluster Guide Version 7.5.1.1 May 2013 Copyright and disclaimer Copyright 2003, 2013, Oracle and/or its affiliates. All rights reserved. Oracle and Java are registered trademarks of
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
Learn AX: A Beginner s Guide to Microsoft Dynamics AX. Managing Users and Role Based Security in Microsoft Dynamics AX 2012. Dynamics101 ACADEMY
Learn AX: A Beginner s Guide to Microsoft Dynamics AX Managing Users and Role Based Security in Microsoft Dynamics AX 2012 About.com is a Rand Group Knowledge Center intended to provide our clients, and
3. Programming the STM32F4-Discovery
1 3. Programming the STM32F4-Discovery The programming environment including the settings for compiling and programming are described. 3.1. Hardware - The programming interface A program for a microcontroller
AN1754 APPLICATION NOTE
AN1754 APPLICATION NOTE DATA LOGGING PROGRAM FOR TESTING ST7 APPLICATIONS VIA ICC by Microcontroller Division Application Team INTRODUCTION Data logging is the process of recording data. It is required
Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference
Job Management Partner 1 Version 10 Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference 3021-3-353(E) Relevant program products
An Introduction to MPLAB Integrated Development Environment
An Introduction to MPLAB Integrated Development Environment 2004 Microchip Technology Incorporated An introduction to MPLAB Integrated Development Environment Slide 1 This seminar is an introduction to
Netwrix Auditor for File Servers
Netwrix Auditor for File Servers Quick-Start Guide Version: 7.0 7/7/2015 Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment from
The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example. Select [Project] [New].
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Caution This symbol explains information you need
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,
Interstage Application Server V7.0 Single Sign-on Operator's Guide
Interstage Application Server V7.0 Single Sign-on Operator's Guide Single Sign-on Operator's Guide - Preface Trademarks Trademarks of other companies are used in this user guide only to identify particular
How To Write Tvalue Amortization Software
TimeValue Software Amortization Software Version 5 User s Guide s o f t w a r e User's Guide TimeValue Software Amortization Software Version 5 ii s o f t w a r e ii TValue Amortization Software, Version
Lepide Software. LepideAuditor for File Server [CONFIGURATION GUIDE] This guide informs How to configure settings for first time usage of the software
Lepide Software LepideAuditor for File Server [CONFIGURATION GUIDE] This guide informs How to configure settings for first time usage of the software Lepide Software Private Limited, All Rights Reserved
DsPIC HOW-TO GUIDE Creating & Debugging a Project in MPLAB
DsPIC HOW-TO GUIDE Creating & Debugging a Project in MPLAB Contents at a Glance 1. Introduction of MPLAB... 4 2. Development Tools... 5 3. Getting Started... 6 3.1. Create a Project... 8 3.2. Start MPLAB...
SkyRecon Cryptographic Module (SCM)
SkyRecon Cryptographic Module (SCM) FIPS 140-2 Documentation: Security Policy Abstract This document specifies the security policy for the SkyRecon Cryptographic Module (SCM) as described in FIPS PUB 140-2.
Rational Rational ClearQuest
Rational Rational ClearQuest Version 7.0 Windows Using Project Tracker GI11-6377-00 Rational Rational ClearQuest Version 7.0 Windows Using Project Tracker GI11-6377-00 Before using this information, be
VERITAS NetBackup Microsoft Windows User s Guide
VERITAS NetBackup Microsoft Windows User s Guide Release 3.2 Windows NT/95/98 May, 1999 P/N 100-001004 1994-1999 VERITAS Software Corporation. All rights reserved. Portions of this software are derived
Logix5000 Controllers Import/Export Project Components
Programming Manual Logix5000 Controllers Import/Export Project Components Catalog Numbers 1768-L43, 1768-L45 Important user information Read this document and the documents listed in the additional resources
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
SIMATIC. Programming with STEP 7 Lite V3.0. Preface, Contents Introducing the Product and Installing the Software. Basics of Designing a Program 2
s SIMATIC Programming with STEP 7 Lite V3.0 Manual Preface, Contents Introducing the Product and Installing the Software 1 Basics of Designing a Program 2 Startup and Operation 3 Setting Up and Editing
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
HP Service Manager. Software Version: 9.40 For the supported Windows and Linux operating systems. Application Setup help topics for printing
HP Service Manager Software Version: 9.40 For the supported Windows and Linux operating systems Application Setup help topics for printing Document Release Date: December 2014 Software Release Date: December
Hardware and Software Requirements
C Compiler Real-Time OS Simulator Training Evaluation Boards Installing and Using the Keil Monitor-51 Application Note 152 May 31, 2000, Munich, Germany by Keil Support, Keil Elektronik GmbH [email protected]
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
How To Backup A Database In Navision
Making Database Backups in Microsoft Business Solutions Navision MAKING DATABASE BACKUPS IN MICROSOFT BUSINESS SOLUTIONS NAVISION DISCLAIMER This material is for informational purposes only. Microsoft
8051 MICROCONTROLLER COURSE
8051 MICROCONTROLLER COURSE Objective: 1. Familiarization with different types of Microcontroller 2. To know 8051 microcontroller in detail 3. Programming and Interfacing 8051 microcontroller Prerequisites:
Installation Guide. Wyse S Class Conversion to ThinOS. Wyse Simple Imager TM Release 2.0.2. Issue: 092611 PN: 883887-04L Rev. C
Installation Guide Wyse S Class Conversion to ThinOS Wyse Simple Imager TM Release 2.0.2 Issue: 092611 PN: 883887-04L Rev. C Copyright Notices 2011, Wyse Technology Inc. All rights reserved. This manual
Industry White Paper. Ensuring system availability in RSView Supervisory Edition applications
Industry White Paper Ensuring system availability in RSView Supervisory Edition applications White Paper Ensuring system availability in RSView Supervisory Edition applications Rockwell Software, Visualization
TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer
i-stat TECHNICAL BULLETIN Configuring Wireless Settings in an i-stat 1 Wireless Analyzer Before configuring wireless settings, please enable the wireless functionality by referring to the Technical Bulletin
AN220 USB DRIVER CUSTOMIZATION
USB DRIVER CUSTOMIZATION Relevant Devices This application note applies to the following devices: CP2101/2/3/4/5/8, C8051F320/1/6/7, C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D, C8051F380/1/2/3/4/5/6/7, C8051T320/1/2/3/6/7,
Netwrix Auditor for Windows Server
Netwrix Auditor for Windows Server Quick-Start Guide Version: 7.0 7/7/2015 Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment from
Chapter 3: Operating-System Structures. Common System Components
Chapter 3: Operating-System Structures System Components Operating System Services System Calls System Programs System Structure Virtual Machines System Design and Implementation System Generation 3.1
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
JP1/IT Desktop Management 2 - Agent (For UNIX Systems)
JP1 Version 11 JP1/IT Desktop Management 2 - Agent (For UNIX Systems) 3021-3-B62(E) Notices Relevant program products JP1/IT Desktop Management 2 - Additional License for Linux P-8142-7GBL JP1/IT Desktop
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
Using HiTOP with the HOT16x Hands-On Training Materials
HOT16x-4 An Add-On to the HOT16x Hands-On Training Materials for the C166 Family using the HiTOP Debugger (from Hitex; plus DAvE, the kitcon-16x Starter Kit, the Keil or Tasking C-Compiler, and an oscilloscope)
NDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc.
NDA-30141 ISSUE 1 STOCK # 200893 CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications,
Netwrix Auditor for Active Directory
Netwrix Auditor for Active Directory Quick-Start Guide Version: 7.1 10/26/2015 Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
UTILITY INSTRUCTION MANUAL BNP-B2196 (ENG)
UTILITY INSTRUCTION MANUAL BNP-B2196 (ENG) MELDASMAGIC is a registered trademark of Mitsubishi Electric Corporation. Microsoft and Windows are registered trademark of Microsoft Corporation in the USA.
Nortel Networks Symposium Call Center Server
297-2183-922 Nortel Networks Symposium Call Center Server for M1/Succession 1000 Administrator s Guide Product release 5.0 Standard 1.0 April 2004 Nortel Networks Symposium Call Center Server for M1/Succession
ROM Monitor. Entering the ROM Monitor APPENDIX
APPENDIX B This appendix describes the Cisco router ROM monitor (also called the bootstrap program). The ROM monitor firmware runs when the router is powered up or reset. The firmware helps to initialize
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES TECHNICAL ARTICLE November/2011. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
JD Edwards World. Database Audit Manager Release A9.3 E21957-02
JD Edwards World Database Audit Manager Release A9.3 E21957-02 April 2013 JD Edwards World Database Audit Manager, Release A9.3 E21957-02 Copyright 2013, Oracle and/or its affiliates. All rights reserved.
BrightStor ARCserve Backup for Linux
BrightStor ARCserve Backup for Linux Agent for MySQL Guide r11.5 D01213-2E This documentation and related computer software program (hereinafter referred to as the "Documentation") is for the end user's
Cisco UCS Director Payment Gateway Integration Guide, Release 4.1
First Published: April 16, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883
Cybozu Garoon 3 Server Distributed System Installation Guide Edition 3.1 Cybozu, Inc.
Cybozu Garoon 3 Server Distributed System Installation Guide Edition 3.1 Cybozu, Inc. Preface Preface This guide describes the features and operations of Cybozu Garoon Version 3.1.0. Who Should Use This
NETWRIX CHANGE REPORTER SUITE
NETWRIX CHANGE REPORTER SUITE QUICK-START GUIDE Product Version: 2.0 November/2011. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
PL-SM900 Software Mirroring Utility User Manual
PL-SM900 Software Mirroring Utility User Manual Digital Electronics Corporation Preface Preface Thank you for purchasing Pro-face's PL-SM900 Software Mirroring Utility, hereafter referred to as the "PL-SM900".
IBM Gentran:Server for Microsoft Windows. HIPAA and NCPDP Compliance Guide
IBM Gentran:Server for Microsoft Windows HIPAA and NCPDP Compliance Guide Version 5.3 4232-520-USER29-0001 Copyright This edition applies to the 5.3 Version of IBM Sterling Gentran:Server for Microsoft
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Version 9.0 User Guide 302-001-755 REV 01 Copyright 2007-2015 EMC Corporation. All rights reserved. Published in USA. Published
Share Point Document Management For Sage 100 ERP
Share Point Document Management For Sage 100 ERP 457 Palm Drive Glendale, CA 91202 818-956-3744 818-956-3746 [email protected] www.iigservices.com Share Point Document Management 2 Information in this
TASKE Call Center Management Tools
TASKE Call Center Management Tools Version 7 Integrating and Configuring Blue Pumpkin PrimeTime and PrimeTime Skills TASKE Technology Inc. Copyright 2000, TASKE Technology Inc. All rights reserved. Printed