Digital Imaging and Communications in Medicine (DICOM)
|
|
|
- Ella Taylor
- 9 years ago
- Views:
Transcription
1 Digital Imaging and Communications in edicine (DICO) Supplement 91: Ophthalmic Photography Image SOP Classes Prepared by: DICO Standards Committee 1300 N. 17 th Street Suite 1847 Rosslyn, Virginia USA VERSION: Final Text, September 29, 2004.
2 Table of Contents Supplement 91 Ophthalmic Photography Image SOP Classes Page 2 Table of Contents... 2 Foreword... 4 Scope and Field of Application... 4 Part 3 Additions... 6 Part 3 Annex A Additions... 8 A.41 Ophthalmic Photography 8 Bit Image Information Object Definition... 9 A.41.1 Ophthalmic Photography 8 Bit Image IOD Description... 9 A.41.2 Ophthalmic Photography 8 Bit Image IOD Entity-Relationship odel... 9 A.41.3 Ophthalmic Photography 8 Bit Image IOD odules... 9 A.41.4 Ophthalmic Photography 8 Bit Image IOD Content Constraints A.42 Ophthalmic Photography 16 Bit Image Information Object Definition A.42.1 Ophthalmic Photography 16 Bit Image IOD Description A.42.2 Ophthalmic Photography 16 Bit Image IOD Entity-Relationship odel A.42.3 Ophthalmic Photography 16 Bit Image IOD odules A.42.4 Ophthalmic Photography 16 Bit Image IOD Content Constraints A.43 Stereometric Relationship Information Object Definition A.43.1 Stereometric Relationship IOD Entity-Relationship odel A.43.2 Stereometric Relationship IOD odules Part 3 Annex C Additions C.8.17 Ophthalmic Photography odules C.8.18 Stereometric odules Annex U Ophthalmology Use Cases (Informative) U.1 Use Cases U.1.1 Routine N-spot exam U.1.2 Routine N-spot exam with exceptions U.1.3 Routine Flourescein Exam U.1.4 External examination U.1.5 External examination with intention U.1.6 External examination with drug application U.1.7 Routine stereo camera examination U.2 Typical Sequence of Events Part 4 Additions B.5 Standard SOP Classes I.4 edia Standard Storage SOP Classes Part 6 Additions Part 16 Additions... 31
3 Supplement 91: Ophthalmic Photography Image SOP Classes Page 3 CID 4200 Ophthalmic Imaging Agent CID 4201 Patient Eye ovement Command CID 4202 Ophthalmic Photography Acquisition Device CID 4203 Ophthalmic Photography Illumination CID 4204 Ophthalmic Filter CID 4205 Ophthalmic Lens CID 4206 Ophthalmic Channel Description CID 4207 Ophthalmic Image Position CID 4208 ydriatic Agent CID 4209 Ophthalmic Anatomic Structure Imaged CID 7202 Source Image Purposes of Reference CID 29 Acquisition odaliy Annex D DICO Controlled Terminology Definitions (Normative)... 38
4 Supplement 91 Ophthalmic Photography Image SOP Classes Page 4 Foreword This Supplement to the DICO Standard introduces three new IODs and SOP Classes for ophthalmic photographic imaging techniques using visible and near-visible light. The first two IODs are for ophthalmic images, while the third is used to define image relationships for stereoscopic pairs of images. The new IODs will be used with several types of ophthalmic photographic imaging devices that use light and optics to produce images of external anatomy and the cornea, and also internal retinal structures. Images created may be single frame or multiframe, color or monochrome. Ophthalmic photographic imaging may incorporate magnification, dyes and color filters, and stereoscopic photography. Ophthalmic photographic imaging requires very specific and detailed identification of equipment used and related acquisition attributes for proper interpretation of the images. This supplement does not address optical coherence tomography (OCT) or ophthalmic endoscopy. For ophthalmic endoscopy, the existing single and multiframe VL or Video Endoscopic Image Storage SOP Classes shall be used. This Supplement proposes changes to the following Parts of the DICO Standard: PS PS PS PS3.16 Information Object Definitions Service Class Specifications Data Dictionary Content apping Resource Scope and Field of Application anufacturers of ophthalmic photographic imaging devices have transitioned from film to creating digital data directly, and have identified the need for a compatible DICO Image Object Definition for information exchange. Working Group 9 evaluated the Photographic Visible Light IOD and the new multiframe Secondary Capture IODs for adequate representation of fundus images. Some of the reasons these existing IODs are not adequate are: a. Equipment made for ophthalmic photographic imaging includes a wide variety of light sources, lens systems, and digital camera types. The viewer of ophthalmic images sometimes needs specific equipment descriptions for proper interpretation. The General Equipment and the SC Equipment odules specified in the VL and SC image object definitions are supplemented with an ophthalmic equipment module for adequate identification. b. Fundus photography and fluorescein angiography devices produce combinations of single images, multiple images, and cine datasets depending on the type of equipment and procedures performed. The proposed SOP classes will provide the flexibility to exchange all of these image formats by using a multiframe module. c. An important basic requirement for ophthalmic photographic imaging is to identify stereoscopic pairs, left and right eye image sets, and angiographic image sets. Stereoscopic pairs of images are kept together through the use of a new stereoscopic relationship entity. d. An important basic requirement for ophthalmic contrast agent based procedures (such as Fluorescein and ICG angiography) is to identify time stamping for angiographic image sets. Synchronization and time attributes are included in these modules to provide the necessary temporal relationships.
5 Supplement 91: Ophthalmic Photography Image SOP Classes Page 5 50 e. Because the proposed IODs encompass several photographic imaging techniques, an extended acquisition specification and corresponding code values will be required for complete descriptions. The expected use cases are described below in an informative annex that will become part of the standard.
6 Supplement 91 Ophthalmic Photography Image SOP Classes Page 6 Part 3 Additions 55 odify PS3.3 Table A.1-1 to add new IOD: Ophthalmic Photography Imaging IODs odules 8-bit Ophth 16-bit Ophth Patient Specimen Identification Clinical Trial Subject U U U U General Study Patient Study U U Clinical Trial Study U U General Series Ophthalmic Series Clinical Trial Series U U Synchronization General Equipment SC Equipment General Image Image Plane Image Pixel Enhanced Contrast/Bolus C C Cine C C ulti-frame Ophthalmic Photography Image Ocular Region
7 Supplement 91: Ophthalmic Photography Image SOP Classes Page 7 Imaged Ophthalmic Photography Acquisition Parameters Ophthalmic Photographic Parameters SOP Common 60 odify PS3.3 Table A.1-2 to add a new module: Stereometric Relationship Table A.1-2 COPOSITE INFORATION OBJECT ODULES OVERVIEW - NON-IAGES IODs odules Stereo metric Reltn Patient Patient Summary Specimen Identification C Clinical Trial Subject U General Study Patient Study U Clinical Trial Study U Study Content General Series Clinical Trial Series U Stereometric Series Presentation Series SR Document Series Key Object Document Series Frame Of Reference
8 Supplement 91 Ophthalmic Photography Image SOP Classes Page 8 Synchronization Cardiac Synchronization Respiratory Synchronization Bulk otion Synchronization General Equipment General Image Image Plane Image Pixel ulti-frame Stereometric Relationship SR Document General SR Document Content Key Object Document Softcopy VOI LUT Softcopy Presentation LUT Image Histogram Presentation State LUT Identification Acquisition Context 65 Common Instance Reference SOP Common Part 3 Annex A Additions 70
9 Supplement 91: Ophthalmic Photography Image SOP Classes Page 9 odify PS3.3 Annex A A.41 Ophthalmic Photography 8 Bit Image Information Object Definition This Section defines an Information Object to be used with several types of ophthalmic photographic imaging devices including fundus cameras, slit lamp cameras, scanning laser devices, stereoscopic cameras, video equipment and digital photographic equipment, with 8 bit resolution per pixel in each image plane. A.41.1 Ophthalmic Photography 8 Bit Image IOD Description The Ophthalmic Photography 8 Bit Image IOD specifies a single-frame or a multi-frame image acquired on a digital photographic DICO modality. This IOD can be used to encode single ophthalmic images and cine sequences. A.41.2 odel Ophthalmic Photography 8 Bit Image IOD Entity-Relationship The E-R odel in Section A.1.2 of this Part depicts those components of the DICO Information odel that directly reference the Ophthalmic Photography 8-Bit Image IOD, with exception of the Curve, VOI LUT, and odality LUT entities, which are not used. Table A.41-1 specifies the odules of the Ophthalmic Photography 8 Bit Image IOD. A.41.3 Ophthalmic Photography 8 Bit Image IOD odules Table A.41-1 OPHTHALIC PHOTOGRAPHY 8 BIT IAGE IOD ODULES IE odule Reference Usage Patient Patient C Specimen Identification C C - Required if the Imaging Subject is a Specimen Clinical Trial Subject C U Study General Study C Patient Study C U Clinical Trial Study C U Series General Series C Frame of Reference Ophthalmic Photography Series C Clinical Trial Series C U Synchronization C Equipment General Equipment C Image General Image C Image Pixel C Enhanced Contrast/Bolus C b C Required if contrast was administered, see A Cine C C - Required if there is a sequential temporal relationship between all frames ulti-frame C Ophthalmic C
10 Photography Image Ocular Region Imaged Ophthalmic Photography Acquisition Parameters Ophthalmic Photographic Parameters Supplement 91 Ophthalmic Photography Image SOP Classes Page 10 C C C SOP Common C A.41.4 Ophthalmic Photography 8 Bit Image IOD Content Constraints The following constraints on Series and Image attributes take precedence over the descriptions given in the odule Attribute Tables. A Bits Allocated, Bits Stored, and High Bit For Ophthalmic Photography 8 bit images, the Enumerated Value of Bits Allocated (0028,0100) (Image Pixel odule, C.7.6.3) shall be 8; the Enumerated Value of Bits Stored (0028,0101) shall be 8; and the Enumerated Value of High Bit (0028,0102) shall be 7. A Contrast/Bolus Agent Sequence For Contrast/Bolus Agent Sequence (0018,0012), the defined CID 4200 shall be used. A.42 Ophthalmic Photography 16 Bit Image Information Object Definition This Section defines an Information Object to be used with several types of ophthalmic photographic imaging devices including fundus cameras, slit lamp cameras, scanning laser devices, stereoscopic cameras, video equipment and digital photographic equipment, with16 bit resolution per pixel in each image plane. A.42.1 Ophthalmic Photography 16 Bit Image IOD Description The Ophthalmic Photography 16 Bit Image IOD specifies a single-frame or a multi-frame image acquired on a digital photographic DICO modality. This IOD can be used to encode single ophthalmic images and other combinations including cine sequences. A.42.2 odel Ophthalmic Photography 16 Bit Image IOD Entity-Relationship The E-R odel in Section A.1.2 of this Part depicts those components of the DICO Information odel that directly reference the Ophthalmic Photography 16-Bit Image IOD, with exception of the Curve, VOI LUT, Frame of Reference and odality LUT entities, which are not used. Table A.42-1 specifies the odules of the Ophthalmic Photography 16 Bit Image IOD. A.42.3 Ophthalmic Photography 16 Bit Image IOD odules Table A.42-1 OPHTHALIC PHOTOGRAPHY 16 BIT IAGE IOD ODULES IE odule Reference Usage Patient Patient C Specimen Identification C C - Required if the Imaging Subject is a Specimen
11 Supplement 91: Ophthalmic Photography Image SOP Classes Page 11 Clinical Trial Subject C U Study General Study C Patient Study C U Clinical Trial Study C U Series General Series C Frame of Reference Ophthalmic Photography Series C Clinical Trial Series C U Synchronization C Equipment General Equipment C Image General Image C Image Pixel C Enhanced Contrast/Bolus C b C Required if contrast was administered; see A Cine C C - Required if there is a sequential temporal relationship between all frames ulti-frame C Ophthalmic Photography Image Ocular Region Imaged Ophthalmic Photography Acquisition Parameters Ophthalmic Photographic Parameters C C C C SOP Common C A.42.4 Ophthalmic Photography 16 Bit Image IOD Content Constraints The following constraints on Series and Image attributes take precedence over the descriptions given in the odule Attribute Tables. A Bits Allocated, Bits Stored, and High Bit For Ophthalmic Photography 16 bit images, the Enumerated Value of Bits Allocated (0028,0100) (Image Pixel odule, C.7.6.3) shall be 16; the Enumerated Value of Bits Stored (0028,0101) shall be 16; and the Enumerated Value of High Bit (0028,0102) shall be 15. A Contrast/Bolus Agent Sequence For Contrast/Bolus Agent Sequence (0018,0012), the defined CID 4200 shall be used. 130 odify PS3.3 Annex A
12 Supplement 91 Ophthalmic Photography Image SOP Classes Page A.43 Stereometric Relationship Information Object Definition This Section defines an Information Object to be used for linking together images belonging to stereoscopic pairs. A Series IE will typically contain a single Stereometric Relationship IE that references one or more sets of stereoscopic images. Stereoscopic pairs for ophthalmic photographic imaging may include single images, multi-frame images, or cine images. A.43.1 Stereometric Relationship IOD Entity-Relationship odel Patient 1 is the subject of Study 1,n 1 contains 1,n Series creates 1,n 1 1 Equipment contains 0,n Stereometric Relationship 140 Figure A.43-1 STEREOETRIC RELATIONSHIP INFORATION OBJECT DEFINITION E-R ODEL 145 A.43.2 Stereometric Relationship IOD odules Table A.43-2 STEREOETRIC RELATIONSHIP IOD ODULES IE odule Reference Usage Patient Patient C Specimen Identification C C - Required if the Imaging Subject is a Specimen
13 Supplement 91: Ophthalmic Photography Image SOP Classes Page 13 Clinical Trial Subject C Study General Study C Series Patient Study C U Clinical Trial Study C U Clinical Trial Series C U Stereometric Series C Equipment General Equipment C Stereometric Relationship Stereometric Relationship odule Common Instance Reference odule C C.12.2 SOP Common C.12.1 U Part 3 Annex C Additions 150 odify PS3.3 Annex C Add to the list of odality (0008,0060) Defined Terms (C ) OP = Ophthalmic Photography SR = Stereometric Relationship 155 odify PS3.3 Annex C 160 C.8.17 Ophthalmic Photography odules C Ophthalmic Photography Series odule Table C specifies the attributes that describe an Ophthalmic Photography Series. Table C OPHTHALIC PHOTOGRAPHY SERIES ODULE ATTRIBUTES Attribute Name Tag Type Attribute Description odality (0008,0060) 1 Source equipment that produced the Ophthalmic Photography Series. Enumerated Value: OP 165 C Ophthalmic Photography Image odule Table C specifies the Attributes that describe an Ophthalmic Photography Image produced by Ophthalmic Photography equipment (OP) imaging odalities. Table C OPHTHALIC PHOTOGRAPHY IAGE ODULE ATTRIBUTES
14 Supplement 91 Ophthalmic Photography Image SOP Classes Page 14 Attribute Name Tag Type Attribute Description Image Type (0008,0008) 1 Image identification characteristics. See C for specialization. Instance Number (0020,0013) 1 A number that identifies this image. Samples per Pixel (0028,0002) 1 Number of samples (planes) in this image. Enumerated values: 1 or 3. See C for further explanation. Samples per Pixel Used Photometric Interpretation Pixel Representation Planar Configuration (0028,0003) 1C The number of samples (planes) containing information. Enumerated value: 2. Required if different from Samples per Pixel (0028,0002). See section C (0028,0004) 1 Specifies the intended interpretation of the pixel data. See section C (0028,0103) 1 Data representation of the pixel samples. Enumerated value: 0 (0028,0006) 1C Indicates whether the pixel data are sent color-by-plane or color-by-pixel. Required if Samples per Pixel (0028,0002) has a value greater than 1. Enumerated value shall be 0 (color-by-pixel). Pixel Spacing (0028,0030) 1C Nominal physical distance at the focal plane (in the retina) between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. Note: These values are specified as nominal because the physical distance may vary across the field of the images and the lens correction is likely to be imperfect. Required when Acquisition Device Type Code Sequence (0022,0015) contains an item with the value (SRT, R- 1021A, Fundus Camera ). ay be present otherwise. Content Time (0008,0033) 1 The time the image pixel data creation started. Content Date (0008,0023) 1 The date the image pixel data creation started. Acquisition Datetime Source Image Sequence (0008,002A) 1C The date and time that the acquisition of data started. Note: The synchronization of this time with an external clock is specified in the synchronization odule in Acquisition Time Synchronized (0018,1800). Required if Image Type (0008,0008) Value 1 is ORIGINAL. ay be present otherwise. (0008,2112) 2C A Sequence that identifies the set of Image SOP Class/Instance pairs of the Images that were used to derive this Image. Required if Image Type Value 1 is DERIVED. Zero or more items may be present in the sequence. See C for further explanation. >Include Image SOP Instance Reference acro, Table 10-3 >Purpose of Reference Code Sequence (0040,A170) 1C Describes the purpose for which the reference is made, that is what role the source image or frame(s) played in the derivation of this image.
15 Supplement 91: Ophthalmic Photography Image SOP Classes Page 15 >>Include Code Sequence acro Table Defined Context ID is Lossy Image Compression Lossy Image Compression Ratio Lossy Image Compression ethod Presentation LUT Shape (0028,2110) 1 Specifies whether an Image has undergone lossy compression. Enumerated Values: 00 = Image has NOT been subjected to lossy compression. 01 = Image has been subjected to lossy compression. See C (0028,2112) 1C Describes the approximate lossy compression ratio(s) that have been applied to this image. See C for further explanation. ay be multivalued if successive lossy compression steps have been applied. Notes: 1. For example, a compression ratio of 30:1 would be described in this Attribute with a single value of For historical reasons, the lossy compression ratio should also be described in Derivation Description (0008,2111) Required if Lossy Image Compression (0028,2110) has a value of 01. (0028,2114) 1C A label for the lossy compression method(s) that have been applied to this image. See C for further explanation. ay be multivalued if successive lossy compression steps have been applied; the value order shall correspond to the values of Lossy Image Compression Ratio (0028,2112). Required if Lossy Image Compression (0028,2110) has a value of 01. Note: For historical reasons, the lossy compression method should also be described in Derivation Description (0008,2111). (2050,0020) 1C Specifies an identity transformation for the Presentation LUT, such that the output of all grayscale transformations defined in the IOD containing this odule are defined to be P-Values. Enumerated Values: IDENTITY - output is in P-Values. Required if Photometric Interpretation (0028,0004) is ONOCHROE2 Calibration Image (0050,0004) 3 Indicates whether a reference object (phantom) of known size is present in the image and was used for calibration. Enumerated Values: YES Burned In Annotation NO (0028,0301) 1 Indicates whether or not image contains sufficient burned in annotation to identify the patient and date the image was acquired. Enumerated Value: YES
16 Supplement 91 Ophthalmic Photography Image SOP Classes Page 16 NO C C Ophthalmic Photography Image odule Attribute Descriptions Referenced Image Sequence The Referenced Image Sequence (0008,1140) in the General Image odule (Section C.7.6.1) shall not convey stereoscopic information, which instead shall be encoded using the Stereometric Relationship IOD. C Samples per Pixel and Samples per Pixel Used Samples per Pixel (0028,0002) shall be 1 or 3. Cameras producing 2-color images are required to use a value of 3 for Samples per Pixel (0028,0002) and a value of 2 for Samples per Pixel Used (0028,0003). For 2-color images with a RGB Photometric Interpretation, the R and G channel shall be used and the B channel shall have all values set to zero. Note: In the case of Photometric Interpretations typically used for compression such as YBR_FULL_422, the encoding will be as if the RGB values were transformed to YCbCr C Photometric Interpretation Specifies the intended interpretation of the pixel data. Enumerated Values shall be: ONOCHROE2 RGB YBR_FULL_422 YBR_PARTIAL_420 YBR_ICT YBR_RCT C Image Type The Image Type attribute (0008,0008) (General Image odule, C.7.6.1) identifies important image characteristics in a multiple valued data element. For the Ophthalmic Photography Image IOD, Image Type is specified as a Type 1 attribute and further specialized as follows: a. Value 1 shall identify the Pixel Data Characteristics in accordance with Section C ; Enumerated Values are: ORIGINAL and DERIVED; b. Value 2 shall identify the Patient Examination Characteristics in accordance with Section C ; Enumerated Value is: PRIARY c. Value 3 shall only be present if Value 1 is DERIVED; Defined Terms: ONTAGE. d. Value 4 (optionally present) shall identify the type of test performed for image acquisition. Defined terms: COLOR - a picture take at white light; no filters applied REDFREE - a picture take at green illumination light; or just the green channel of a color sensor RED - a picture take at red illumination light; or just the red channel of a color sensor BLUE - a picture take at blue illumination light; or just the blue channel of a color sensor FA- fluorescein injected; a picture taken at fluorescein exciting illumination light; a filter passing just the emitted wavelength to sensor applied
17 Supplement 91: Ophthalmic Photography Image SOP Classes Page 17 ICG - Indocyanine green injected; a picture taken at Indocyanine green exciting illumination light; a filter passing just the emitted wavelength to sensor applied 215 Note: A ontage Image is constructed out of several individual images, which also can be exchanged separately. The images used to create the montage image will be included in the source image sequence if those images are also exchanged. A ontage Image is identified as Image Type DERIVED\PRIARY\ONTAGE 220 C Ophthalmic Photographic Parameters odule This odule describes equipment used to create original images.
18 Supplement 91 Ophthalmic Photography Image SOP Classes Page 18 Table C OPHTHALIC PHOTOGRAPHIC PARAETERS ODULE ATTRIBUTES Attribute Name Tag Type Attribute Description Acquisition Device Type Code Sequence (0022,0015) 1 Describes the type of acquisition device. A single item shall be present in the sequence. >Include Code Sequence acro Table Baseline Context ID is 4202 Illumination Type Code Sequence (0022,0016) 2 Coded value for illumination. Zero or one item shall be present in the sequence. >Include Code Sequence acro Table Baseline Context ID is 4203 Light Path Filter Type Stack Code Sequence (0022,0017) 2 Filters used in the light source path. Zero or more items may be present in the sequence. >Include Code Sequence acro Table Baseline Context ID is 4204 Light Path Filter Pass-Through Wavelength (0022,0001) 3 Nominal pass-through wavelength of light path filter in nm Light Path Filter Pass Band (0022,0002) 3 Pass band of light path filter in nm. This Attribute has two Values. The first is the shorter and the second the longer wavelength relative to the peak. The values are for the 3dB nominal (1/2 of peak) pass through intensity. One of the two Values may be zero length, in which case it is a cutoff filter. Image Path Filter Type Stack Code Sequence (0022,0018) 2 Describes stack of filters used in image path. Zero or more items may be present in the sequence. >Include Code Sequence acro Table Baseline Context ID is 4204 Image Path Filter Pass-Through Wavelength (0022,0003) 3 Nominal pass-through wavelength of image path filter in nm Image Path Filter Pass Band (0022,0004) 3 Pass band of image path filter in nm. This Attribute has two Values. The first is the shorter and the second the longer wavelength relative to the peak. The values are for the 3dB nominal (1/2 of peak) pass through intensity. One of the two Values may be zero length, in which case it is a cutoff filter Lenses Code Sequence (0022,0019) 2 Lenses that were used during the image acquisition. Zero or more items may be present in the sequence. >Include Code Sequence acro Table Baseline Context ID is 4205 Detector Type (0018,7004) 2 Type of detector used for creating this image. Defined terms: CCD = Charge Coupled Devices COS = Complementary etal Oxide Semiconductor
19 Supplement 91: Ophthalmic Photography Image SOP Classes Page 19 Channel Description Code Sequence (0022,001A) 1C Describes the light color used for each channel to generate the image. Required if this differs from the natural interpretation. Note: Interpretation and representation of RGB images rely on the assumption that the red channel really contains the red wavelength range of illumination light, the blue channel the blue wavelength range, etc. Some modalities use the RGB Photometric Interpretation as a container representing 3 channels of any illumination wavelength. Shall have the same number of items as the Value of Samples per Pixel Used (0028,0003) if present, or otherwise the value of Samples per Pixel (0028,0002). The channels shall be described in the order in which the channels are encoded. >Include Code Sequence acro Table Baseline Context ID is C Ophthalmic Photography Acquisition Parameters odule This odule describes patient clinical conditions related to the image acquisition.
20 Supplement 91 Ophthalmic Photography Image SOP Classes Page 20 Table C OPHTHALIC PHOTOGRAPHY ACQUISITION PARAETERS ODULE ATTRIBUTES Attribute Name Tag Type Attribute Description Patient Eye ovement Commanded (0022,0005) 2 Enumerated Values: YES NO Patient Eye ovement Command Code Sequence (0022,0006) 1C Coded value for patient movement or orientation, which is the intent, and not necessarily the result, based on what the patient is capable of. Required if the value of Patient Eye ovement Commanded (0022,0005) is YES. A single item shall be present in this sequence. >Include Code Sequence acro Table Baseline Context ID is 4201 Refractive State Sequence (0022,001B) 2 The refractive state of the imaged eye at the time of acquisition. Zero or one Item shall be present. Absence of an item means the refractive state was not measured. > Spherical Lens Power (0022,0007) 1 Sphere value in diopters > Cylinder Lens Power (0022,0008) 1 Cylinder value in diopters > Cylinder Axis (0022,0009) 1 Axis value in degrees Emmetropic agnification (0022,000A) 2 Emmetropic agnification value (dimensionless). Zero length means the emmetropic magnification was not measured. Intra Ocular Pressure (0022,000B) 2 Value of pressure. Value in mmhg. Zero length means the pressure was not measured. Horizontal Field of View (0022,000C) 2 The horizontal field of view in degrees Pupil Dilated (0022,000D) 2 Enumerated Values: YES NO 230 ydriatic Agent Code Sequence (0022,001C) 2C The agent administered to dilate the pupil. Required if the value of Pupil Dilated (0022,000D) is YES. Zero or more items may be present. >Include Code Sequence acro Table Baseline Context ID is 4208 Degree of Dilation (0022,000E) 2C The degree of the dilation in mm Required if the value of Pupil Dilated (0022,000D) is YES.
21 235 Supplement 91: Ophthalmic Photography Image SOP Classes Page 21 C Ocular Region Imaged odule Table C contains IOD Attributes that describe the anatomy contained in an OP IOD. Table C OCULAR REGION IAGED ODULE ATTRIBUTES Attribute Name Tag Type Attribute Description Image Laterality (0020,0062) 1 Laterality of object imaged (as described in Anatomic Region Sequence (0008,2218)) examined. Enumerated Values: R = right eye L = left eye B = both left and right eye Shall be consistent with any laterality information contained in Primary Anatomic Structure odifier Sequence (0008,2230), Relative Image Position Code Sequence if present. Note: Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series. Since most Ophthalmic Photographic Image studies contain images of both eyes, the series level attribute will rarely be present. (0022,001D) 3 The position of this image on the retina (as defined by a specified nomenclature; the nomenclature is implicit in the code used). >Include Code Sequence acro Table Baseline Context ID 4207 Include 'General Anatomy andatory acro' Table 10-5 Defined Context ID 4209 for Anatomic Region Sequence odify PS3.3 Annex C 240 C.8.18 C Stereometric odules Stereometric Series odule Table C specifies the Attributes that describe a Stereometric Series produced by Ophthalmic Photography equipment (OP) imaging odalities. Table C STEREOETRIC SERIES ODULE ATTRIBUTES
22 Supplement 91 Ophthalmic Photography Image SOP Classes Page 22 Attribute Name Tag Type Attribute Description odality (0008,0060) 1 Source equipment that produced the Stereometric Series. Enumerated Value: SR C Stereometric Relationship odule The stereometric relationship module is used to identify pairs of images that may be viewed in stereo. It is possible that the same image or frame may be a member of multiple pairs. The images forming a pair shall be in different SOP Instances. The images forming a pair can be in different Series. All Instances referenced in this odule shall be in the same Study as the Instance in which the odule occurs. 255 Table C STEREOETRIC RELATIONSHIP ODULE ATTRIBUTES Attribute Name Tag Type Attribute Description Stereo Pairs Sequence (0022,0020) 1 Sequence of items identifying pairs of images. There shall be one or more items in this sequence. >Stereo Baseline Angle (0022,0010) 3 Stereo separation angle in degrees >Stereo Baseline Displacement (0022,0011) 3 Horizontal displacement of instrument between left and right image in mm >Stereo Horizontal Pixel Offset (0022,0012) 3 Horizontal displacement of right image relative to left image in pixels for optimal display. Offset of right image to right means positive value. >Stereo Vertical Pixel Offset (0022,0013) 3 Vertical displacement of right image relative to left image in pixels for optimal display. Offset of right image downwards means positive value. >Stereo Rotation (0022,0014) 3 Rotation of right image relative to left image in degrees for optimal display. The rotation of the right image against the left image counterclockwise is positive, rotation around the center is assumed. >Left Image Sequence (0022,0021) 1 Left Image of the Pair. Only one Item shall be present in this Sequence. >>Include Image SOP Instance Reference acro, Table 10-3 The Referenced SOP Instance UID (0008,1155) shall not be the same as the Referenced SOP Instance UID (0008,1155) of the Right Image Sequence (0022,0022). >Right Image Sequence (0022,0022) 1 Right Image of the Pair. Only one Item shall be present in this Sequence. >>Include Image SOP Instance Reference acro, Table 10-3 The Referenced SOP Instance UID (0008,1155) shall not be the same as the Referenced SOP Instance UID (0008,1155) of the Left Image Sequence (0022,0021).
23 Supplement 91: Ophthalmic Photography Image SOP Classes Page C C Stereometric Relationship odule Attribute Descriptions Left and Right Image Sequences The images referenced by the Left Image Sequence (0022,0021) and Right Image Sequence (0022,0022) in a single Stereo Pairs Sequence Item shall have the same values for Rows (0028,0010) and the same values for Columns (0028,0011). The reference may be to images with a single frame, all the frames of images with multiple frames, or one or more selected frames within an image with multiple frames. If multiple frames are selected, the same number of frames shall be referenced from both sequences.
24 Supplement 91 Ophthalmic Photography Image SOP Classes Page Add to PS3.17 Annex U Annex U Ophthalmology Use Cases (Informative) U.1 Use Cases The following use cases are examples of how the DICO Ophthalmology Photography objects may be used. These use cases utilize the term picture or pictures to avoid using the DICO terminology of frame, instance or image. In the use cases, the series means DICO Series. U.1.1 Routine N-spot exam An N-spot retinal photography exam means that N predefined locations on the retina are examined. A routine N-spot retinal photography exam is ordered for both eyes. There is nothing unusual observed during the exam, so N pictures are taken of each retina. This healthcare facility also specifies that in an N-spot exam a routine external picture is captured of both eyes, that the current intraocular pressure (IOP) is measured, and that the current refractive state is measured. The resulting study contains: N pictures of the retina and one external picture. Each retinal picture is labeled in the acquisition information to indicate its position in the local N-spot definition. The series is not labeled, each picture is labeled OS or OD as appropriate. Note: DICO uses L, R, and B in the Image Laterality Attribute (0020,0062). The actual encodings will be L, R, or B. Ophthalmic equipment can convert this to OS, OD, and OU before display. In the acquisition information of every picture, the IOP and refractive state information is replicated. Since there are no stereo pictures taken, there is no Stereometric Relationship IOD instance created. The pictures may or may not be in the same Series. U.1.2 Routine N-spot exam with exceptions A routine N-spot retinal photography exam is ordered for both eyes. During the exam a lesion is observed in the right eye. The lesion spans several spots, so an additional wide angle view is taken that captures the complete lesion. Additional narrow angle views of the lesion are captured in stereo. After completing the N-spot exam, several slit lamp pictures are taken to further detail the lesion outline. The resulting study contains: a. 2N pictures of the retina and one external picture, one additional wide angle picture of the abnormal retina, 2 additional pictures for the stereo detail of the abnormal retina, and several slit lamp pictures of the abnormal eye. The different lenses and lighting parameters are documented in the acquisition information for each picture. b. One instance of a Stereometric Relationship IOD, indicating which of the stereo detail pictures above should be used as stereo pairs. The pictures may or may not be in the same Series.
25 Supplement 91: Ophthalmic Photography Image SOP Classes Page 25 U.1.3 Routine Flourescein Exam A routine fluorescein exam is ordered for one eye. The procedure includes: a. Routine stereo N-spot pictures of both eyes, routine external picture, and current IOP. b. Reference stereo picture of each eye using filtered lighting c. Fluorescein injection d. Capture of 20 stereo pairs with about 0.7 seconds between pictures in a pair and 3-5 seconds between pairs. e. Stereo pair capture of each eye at increasing intervals for the next 10 minutes, taking a total of 8 pairs for each eye. The result is a study with: a. The usual 2N+1 pictures from the N-spot exam b. Four pictures taken with filtered lighting (documented in acquisition information) that constitute a stereo pair for each eye. c. 40 pictures (20 pairs) for one eye of near term fluorescein. These include the acquisition information, lighting context, and time stamp. d. 32 pictures (8 pairs for each eye) of long term fluorescein. These include acquisition information, lighting context, and time stamp. e. One Stereometric Relationship IOD, indicating which of the above OP instances should be used as stereo pairs. The pictures of a) through d) may or may not be in the same series. U.1.4 External examination The patient presents with a generic eye complaint. Visual examination reveals a possible abrasion. The general appearance of the eyes is documented with a wide angle shot, followed by several detailed pictures of the ocular surface. A topical stain is applied to reveal details of the surface lesion, followed by several additional pictures. Due to the nature of the examination, no basic ophthalmic measurements were taken. The result is a study with one or more series that contains: a. One overall external picture of both eyes b. Several close-up pictures of the injured eye c. Several close-up pictures of the injured eye after topical stain. These pictures have the additional stain information conveyed in the acquisition information for these pictures. U.1.5 External examination with intention The patient is suspected of a nervous system injury. A series of external pictures are taken with the patient given instructions to follow a light with his eyes. For each picture the location of the light is indicated by the patient intent information, (e.g. above, below, patient left, patient right). The result is a study with one or more series that contains: 345 a. Individual pictures with each picture using the patient intent field to indicate the intended direction.
26 Supplement 91 Ophthalmic Photography Image SOP Classes Page U.1.6 External examination with drug application Patient is suspected of myaesthenia gravis. Both eyes are imaged in normal situation. Then after Tensilon (edrophonium chloride) injection a series of pictures is taken. The time, amount, and method of Tensilon (edrophonium chloride) administration is captured in the acquisition information. The time stamps of the pictures are used in conjunction with the behavior of the eyelids to assess the state of the disease. Note: Tensilon is a registered trademark of Roche Laboratories The result is a study with one or more series that contains: a. ultiple reference pictures prior to test b. Pictures with acquisition information to document drug administration time U.1.7 Routine stereo camera examination A stereo optic disk examination is ordered for a patient with glaucoma. For this examination, the IOP does not need to be measured. The procedure includes: a. ydriasis using agent at time t b. N stereo pictures (camera pictures right and left stereo picture simultaneously) of the optic disk region at the time t+s The result is a study with: a. N right and N left stereo pictures. These include acquisition information, lighting context, agent and time stamps. b. One Stereometric Relationship SOP Instance, indicating that the above OP images should be used as stereo pairs. U.2 Typical Sequence of Events The following shows the proposed sequence of events using individual images that are captured for later stereo viewing, with the stereo viewing relationships captured in the stereometric relationship instance. 375
27 Supplement 91: Ophthalmic Photography Image SOP Classes Page 27 OP Sop Instances Stored for: B - Both eyes L - Left eye R - Right eye Establish Baseline B L R Acquisition Information A Change Illumination and Filter R L Acquisition Information B Drug Injection Short Term single Eye Angio Capture L L L L... L L R R Pairs of images that are intended for stereo viewing Acquisition Information C and drug Information Long Term Angio Capture L L L L Confirm Stereo Capture Stereometric Relationship SOP Instance The instances captured are all time stamped so that the fluorescein progress can be measured accurately. The acquisition and equipment information captures the different setups that are in use: 380 a. Acquisition information A is the ordinary illumination and planned lenses for the examination.
28 Supplement 91 Ophthalmic Photography Image SOP Classes Page b. Acquisition information B is the filtered illumination, filtered viewing, and lenses appropriate for the fluorescein examination. c. Acquisition information C indicates no change to the equipment settings, but once the injection is made, the subsequent images include the drug, method, dose, and time of delivery. Part 4 Additions 390 Add to PS3.4 Annex B.5. B.5 Standard SOP Classes Table B.5-1 STANDARD SOP CLASSES 395 SOP Class Name SOP Class UID IOD (See PS 3.3) Ophthalmic Photography 8 Bit Image Storage Ophthalmic Photography 16 Bit Image Storage Stereometric Relationship Storage Ophthalmic Photography 8 Bit Image Ophthalmic Photography 16 Bit Image Stereometric Relationship Add to PS3.4 Annex I I.4 edia Standard Storage SOP Classes Table I.4-1 edia Storage Standard SOP Classes SOP Class Name SOP Class UID IOD (See PS 3.3) Ophthalmic Photography 8 Bit Image Storage Ophthalmic Photography 16 Bit Image Storage Stereometric Relationship Storage Ophthalmic Photography 8 Bit Image Ophthalmic Photography 16 Bit Image Stereometric Relationship
29 Supplement 91: Ophthalmic Photography Image SOP Classes Page 29 Part 6 Additions 405 Add to PS3.6 Annex A UID Value UID NAE UID TYPE Part Ophthalmic 8 bit Photography Image Storage Ophthalmic 16 bit Photography Image Storage Stereometric Relationship Storage SOP Class PS 3.4 SOP Class PS 3.4 SOP Class PS Add to PS3.6 the following Data Elements to Section 6, Registry of DICO data elements: Tag Name VR V (0028,0003) Samples per Pixel Used US 1 (0022,0001) Light Path Filter Pass-Through Wavelength US 1 (0022,0002) Light Path Filter Pass Band US 2 (0022,0003) Image Path Filter Pass-Through Wavelength US 1 (0022,0004) Image Path Filter Pass Band US 2 (0022,0005) Patient Eye ovement Commanded CS 1 (0022,0006) Patient Eye ovement Command Code Sequence SQ 1 (0022,0007) Spherical Lens Power FL 1 (0022,0008) Cylinder Lens Power FL 1 (0022,0009) Cylinder Axis FL 1 (0022,000A) Emmetropic agnification FL 1 (0022,000B) Intra Ocular Pressure FL 1 (0022,000C) Horizontal Field of View FL 1 (0022,000D) Pupil Dilated CS 1 (0022,000E) Degree of Dilation FL 1
30 Supplement 91 Ophthalmic Photography Image SOP Classes Page 30 Tag Name VR V (0022,0010) Stereo Baseline Angle FL 1 (0022,0011) Stereo Baseline Displacement FL 1 (0022,0012) Stereo Horizontal Pixel Offset FL 1 (0022,0013) Stereo Vertical Pixel Offset FL 1 (0022,0014) Stereo Rotation FL 1 (0022,0015) Acquisition Device Type Code Sequence SQ 1 (0022,0016) Illumination Type Code Sequence SQ 1 (0022,0017) Light Path Filter Type Stack Code Sequence (0022,0018) Image Path Filter Type Stack Code Sequence SQ 1 SQ 1 (0022,0019) Lenses Code Sequence SQ 1 (0022,001A) Channel Description Code Sequence SQ 1 (0022,001B) Refractive State Sequence SQ 1 (0022,001C) ydriatic Agent Code Sequence SQ 1 (0022,001D) Relative Image Position Code Sequence SQ 1 (0022,0020) Stereo Pairs Sequence SQ 1 (0022,0021) Left Image Sequence SQ 1 (0022,0022) Right Image Sequence SQ 1
31 Supplement 91: Ophthalmic Photography Image SOP Classes Page 31 Part 16 Additions 415 CID 4200 Ophthalmic Imaging Agent Context ID 4200 Ophthalmic Imaging Agent Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT C-B02CC Fluorescein SRT C-B0156 Indocyanine green SRT C-B0295 Rose Bengal SRT C Trypan blue SRT C-B02C5 ethylene blue 420 CID 4201 Patient Eye ovement Command Context ID 4201 Patient Eye ovement Command Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT R-1022D Primary gaze SRT R-404BF Upward gaze SRT R-404B9 Left upgaze SRT R-404BC Left gaze SRT R-404B7 Left downgaze SRT R-404B6 Downgaze SRT R-404B8 Right downgaze SRT R-404BD Right gaze SRT R-404BA Right upgaze SRT R Convergent gaze 425
32 430 CID 4202 Supplement 91 Ophthalmic Photography Image SOP Classes Page 32 Ophthalmic Photography Acquisition Device Context ID 4202 Ophthalmic Photography Acquisition Device Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) SRT R-1021A Fundus Camera SRT A-2B201 Biomicroscope SRT R-1021B External Camera SRT R-1021C Specular icroscope SRT A-2B210 Operating icroscope Code eaning (0008,0104) SRT A-00E8A Scanning Laser Ophthalmoscope SRT R-1021D Indirect Ophthalmoscope SRT R-1021E Direct Ophthalmoscope SRT R-1021F Ophthalmic Endoscope SRT A-00FCA Keratoscope 435 CID 4203 Ophthalmic Photography Illumination Context ID 4203 Ophthalmic Photography Illumination Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT R-1020E Dual diffuse direct illumination SRT R-1020F Fine slit beam direct illumination SRT R Broad tangential direct illumination SRT R Indirect sclerotic scatter illumination SRT R Indirect retroillumination from the iris SRT R Indirect retroillumination from the retina SRT R Indirect iris transillumination Reference: From the OPS web site: 440
33 Supplement 91: Ophthalmic Photography Image SOP Classes Page CID 4204 Ophthalmic Filter Context ID 4204 Ophthalmic Filter Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) DC Green filter DC Red filter DC Blue filter DC Yellow-green filter DC Blue-green filter DC Infrared filter DC Polarizing filter DC No filter Code eaning (0008,0104) CID 4205 Ophthalmic Lens Context ID 4205 Ophthalmic Lens Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT R Indirect ophthalmoscopy lens SRT R Concave contact fundus lens SRT R-1023A Concave noncontact fundus lens SRT R-1023B Contact fundus lens SRT A-00FAD Goniolens SRT R-1023D Convex noncontact fundus lens SRT R-1023E Noncontact fundus lens SRT R-1023C Convex contact fundus len
34 Supplement 91 Ophthalmic Photography Image SOP Classes Page CID 4206 Ophthalmic Channel Description Context ID 4206 Ophthalmic Channel Description Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) SRT G-A12F Blue SRT R-102C0 Full Spectrum SRT G-A11E Green SRT R-102BE Infrared SRT G-A11A Red SRT G-A132 Red free SRT R-102BF Ultraviolet Code eaning (0008,0104) 460 CID 4207 Ophthalmic Image Position Context ID 4207 Ophthalmic Image Position Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT R Diabetic Retinopathy Study field 1 SRT R-1022A Diabetic Retinopathy Study field 2 SRT R-1022B Diabetic Retinopathy Study field 3 SRT R-1022C Diabetic Retinopathy Study field 4 SRT R-1022E Diabetic Retinopathy Study field 5 SRT R-1022F Diabetic Retinopathy Study field 6 SRT R Diabetic Retinopathy Study field 7 DC Field 1 for Joslin 3 field DC Field 2 for Joslin 3 field DC Field 3 for Joslin 3 field 465 CID 4208 ydriatic Agent Context ID 4208 ydriatic Agent Type: Extensible Version:
35 Supplement 91: Ophthalmic Photography Image SOP Classes Page 35 Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT C-677B9 Atropine SRT C-677C0 Homatropine SRT C Cyclopentolate SRT C Phenylephrine SRT C Tropicamide 470 CID 4209 Ophthalmic Anatomic Structure Imaged Context ID 4209 Ophthalmic Anatomic Structure Imaged Type: Extensible Version: Coding Scheme Designator (0008,0102) Code Value (0008,0100) Code eaning (0008,0104) SRT T-AA050 Anterior chamber of eye SRT T-AA180 Both eyes SRT T-AA310 Choroid of eye SRT T-AA400 Ciliary body SRT T-AA860 Conjunctiva SRT T-AA200 Cornea SRT T-AA000 Eye SRT T-AA810 Eyelid SRT T-AA621 Fovea centralis SRT T-AA500 Iris SRT T-AA862 Lacrimal caruncle SRT T-AA910 Lacrimal gland SRT T-AA940 Lacrimal sac SRT T-AA700 Lens SRT T-AA830 Lower Eyelid SRT T Ophthalmic artery SRT T-AA630 Optic nerve head SRT T-AA610 Retina SRT T-AA110 Sclera SRT T-AA820 Upper Eyelid
36 Supplement 91 Ophthalmic Photography Image SOP Classes Page CID 7202 Coding Scheme Designator (0008,0102) Source Image Purposes of Reference Context ID 7202 Source Image Purposes of Reference Type: Extensible Version: Code Value (0008,0100) Code eaning (0008,0104) DC Uncompressed predecessor DC ask image for image processing operation DC Source image for image processing operation DC Source image for montage 480 CID 29 Coding Scheme Designator Acquisition odality Context ID 29 Acquisition odality Type: Extensible Version: Code Value DC EPS Cardiac Electrophysiology DC CR Computed Radiography DC CT Computed Tomography DC DX Digital Radiography DC ECG Electrocardiography DC ES Endoscopy Code eaning DC XC External-camera Photography DC G General icroscopy DC HD Hemodynamic Waveform DC IO Intra-oral Radiography DC IVUS Intravascular Ultrasound DC R agnetic Resonance DC G ammography DC N Nuclear edicine DC OP Ophthalmic Photography DC PX Panoramic X-Ray DC PT Positron emission tomography DC RF Radiofluoroscopy DC RG Radiographic imaging
37 Supplement 91: Ophthalmic Photography Image SOP Classes Page 37 DC RTIAGE Radiotherapy Image DC S Slide icroscopy DC US Ultrasound DC XA X-Ray Angiography 485
38 Supplement 91 Ophthalmic Photography Image SOP Classes Page 38 Add the following definitions to Part 16 Annex D DICO Controlled Terminology Definitions (Normative) 490 Annex D DICO Controlled Terminology Definitions (Normative) Code Value Code eaning Definition Notes OP Ophthalmic photography Ophthalmic photography modality FA Fluorescein Angiography Fluorescein Angiography Retiredreplaced by OP FS Fundoscopy Fundoscopy Retiredreplaced by OP SR Stereometric Relationship Stereometric image pairing modality Source image for montage Image used as a source for a montage (stitched) image Green filter Filter that transmits one third of white light (green) while blocking the other two thirds Red filter Blue filter Yellow-green filter Blue-green filter Infrared filter Polarizing filter No filter No filter used Field 1 for Joslin 3 field Filter that transmits one third of white light (red) while blocking the other two thirds Filter that transmits one third of white light (blue) while blocking the other two thirds A filter of 560nm that is used for retinal imaging and can provide good contrast and good visibility of the retinal vasculature A filter of 490nm that is used for retinal imaging because of excessive scattering of some retinal structures at very short wavelengths Filter that transmits the infrared spectrum, which is light that lies outside of the visible spectrum, with wavelengths longer than those of red light, while blocking visible light A filter that reduces reflections from nonmetallic surfaces such as glass or water by blocking light waves that are vibrating at selected angles to the filter. Joslin N-1 is a 45 degree field focused centrally between the temporal margin of optic disc and the center of the macula: Center the camera on the papillomacular bundle midway between the temporal margin
39 Supplement 91: Ophthalmic Photography Image SOP Classes Page Field 2 for Joslin 3 field Field 3 for Joslin 3 field of the optic disc and the center of the macula. The horizontal centerline of the image should pass directly through the center of the disc Joslin N-2 is a 45 degree field focused superior temporal to the optic disc: Center the camera laterally approximately one-half disc diameter temporal to the center of the macula. The lower edge of the field is tangent to a horizontal line passing through the upper edge of the optic disc. The image is taken temporal to the macula but includes more retinal nasal and superior to the macula than standard field 2. Joslin N-3 is a 45 degree field focused nasal to the optic disc: This field is nasal to the optic disc and may include part of the optic disc. The horizontal centerline of the image should pass tangent to the lower edge of the optic disc.
DICOM Conformance Statement
Revision: 1.0 Date: Sep, 15th 2015 DICOM Conformance Statement VISUCAM 224 and VISUCAM 524 Version 6.0 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena Germany www.zeiss.com/med Document: DICOM_Conformance_Statement_VISUCAM_224_524_6.0.doc
Version 8 DICOM Conformance Statement. Version 3.04, September 2014
Version 8 DICOM Conformance Statement Version 3.04, September 2014 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of processes
DICOM Correction Item
Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes
Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes
Page 1 4 Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes 8 12 16 20 Status: Letter Ballot Text, 29 October, 1999 24 DICOM Standards Committee
DICOM 3.0 Conformance Statement
Version 2.7 DICOM 3.0 Conformance Statement 1 1. Conformance Statement Overview SOP Classes Query and Retrieve Study Root Query/Retrieve Information Model Find Study Root Query/Retrieve Information Model
Digital Imaging and Communications in Medicine (DICOM) Supplement 30: Waveform Interchange
Digital Imaging and Communications in Medicine (DICOM) Supplement 30: Waveform Interchange DICOM Standards Committee, Working Group 1 - Cardiac and Vascular Information 1300 N. 17 th Street, Suite 1847
Digital Imaging and Communications in Medicine (DICOM) Supplement 145: Whole Slide Microscopic Image IOD and SOP Classes
5 Digital Imaging and Communications in Medicine (DICOM) Supplement 145: Whole Slide Microscopic Image IOD and SOP Classes 10 15 20 Prepared by: DICOM Standards Committee, Working Group 26, Pathology 1300
Digital Imaging and Communications in Medicine (DICOM) Supplement 132: Surface Segmentation Storage SOP Class
5 10 Digital Imaging and Communications in Medicine (DICOM) Supplement 132: Surface Segmentation Storage SOP Class 15 20 Prepared by: DICOM Standards Committee, Working Group 17 (3D) and 24 (Surgery) 25
CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0. DICOM Conformance Statement
CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0 DICOM Conformance Statement Publication # 8G8913 22 April 2009 Table of Contents Table of Contents...2 1 Introduction...5 1.1 Abbreviations
Understanding Digital Modalities: System Integration and Use
Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI [email protected] Dicom Digital Imaging and Communications in Medicine Part 3: Information
DICOM Conformance Statement
DICO Conformance Statement IDS5 11.4; IDS7, Sectra Healthcare Server, WISE, ImageServer/s, ImageServer/xd Version 12.2.3, June 2010 About this document Sectra Imtec AB, Sweden, 2010 Disclaimer Sectra Imtec
DICOM Conformance Statement
DICOM Conformance Statement CARESTREAM Vue PACS v11.3.2.4 Lesion Management and Bookmark Applications Part # 6K4188 2012-07-02 PAGE 1 of 142 Table of Contents 1 INTRODUCTION... 4 1.1 ABBREVIATIONS AND
Fundus Photograph Reading Center
Modified 7-Standard Field Digital Color Fundus Photography (7M-D) 8010 Excelsior Drive, Suite 100, Madison WI 53717 Telephone: (608) 410-0560 Fax: (608) 410-0566 Table of Contents 1. 7M-D Overview... 2
MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved
All rights reserved medigration GmbH, Schuhstr. 30, 91052 Erlangen Tel: +49 (0) 9131/69087-40, Fax: +49 (0) 9131/69087-50 www.medigration.de Copyright. All rights reserved. Table of Contens 1 Introduction...
HDI 4000 Ultrasound System
HDI 4000 Ultrasound System DICOM Conformance Statement Rev 1.0 Philips Medical Systems HDI 4000 DICOM Conformance Rev. 1.0 12/17/2001 Philips Medical Systems Table of Contents 0. Introduction...3 0.1 DICOM
DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.
DICOM Conformance Statement DICOMscope 3.5 Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A. Thiel 1 Organizational support: J. Holstein 2, H. Oosterwijk 3 1) Kuratorium
MiPACS Storage Server Conformance Statement Version 1.02.0.000
MiPACS Storage Server Conformance Statement Version 1.02.0.000 December 2009 Version 1.00.4.001 Conformance Statement Document Information Issued by: Medicor Imaging 1927 S. Tryon St., Suite 200 Charlotte,
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
DICOM 3.0 Conformance Statement
Picture Archiving and Communication System DICOM 3.0 Conformance Statement CODE NO.1245 Manufacturer: 1 Sakura-machi, Hino-shi Tokyo 191-8511, Japan Important Notes Konica Minolta Medical & Graphic, Inc.
DICOM Conformance Statement. GDxPRO
Document Number: 2660021133317 Revision: D Date: 01/20/2010 Author: Vidya Kulkarni DICOM Conformance Statement GDxPRO GDxPRO Instrument Software Version 1.1 GDxPRO Review Software Version 1.0 Carl Zeiss
ClearCanvas ImageServer DICOM Conformance Statement
ClearCanvas ImageServer DICOM Conformance Statement Document Version: 2.2 Product Name(s): ClearCanvas ImageServer Release: 11.0 Date: January 12, 2014 ClearCanvas Inc. 1920 439 University Ave. Toronto,
Technical Publications
Technical Publications Direction DOC0708777 Revision 3 Centricity Enterprise Archive V4.0 DICOM CONFORMANCE STATEMENT Copyright 2011 by General Electric Company 1 CONFORMANCE STATEMENT OVERVIEW The Enterprise
Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO. 1118. Manufacturer:
PRINT MANAGEMENT SYSTEM Printlink5-ID_IV DICOM 3.0 Conformance Statement CODE NO. 1118 Manufacturer: 2970 Ishikawa-machi, Hachioji-shi Tokyo 192-8505 Japan DICOM Conformance Statement Important Notes Konica
CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.
CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras Designed for the highest possible image quality. See the smallest details, don t miss pathology. CR-2 AF Extremely compact and lightweight (just 15 kg) camera:
Fig.1. The DAWN spacecraft
Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics
Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, 2010. 2010 Copyright Brainlab AG
Technical Publication DICOM Conformance Statement Document Revision 3 October 20, 2010 2010 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software
HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T4434-96003
HP Medical Archive Solutions DICOM Conformance Statement January 2007 (Third Edition) Part Number Copyright 2007, 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license
Infinity Medical Image Server
Infinity Medical Image Server DICOM Server Conformance Statement Part Number: 900-420-002 Rev. 02 Document/Software Version: v1.3.0 Date: May 12, 2009 Copyright 2008-2009 Codonics, Inc. All Rights Reserved.
Digital Imaging and Communications in Medicine (DICOM) Part 6: Data Dictionary
PS 3.6-2004 Digital Imaging and Communications in Medicine (DICOM) Part 6: Data Dictionary Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright
DICOM Conformance Statement
This printed copy is not subject to any change control XXXXXXXXXXXXxxXXXXXXXXXXXXXXXXXXX MR 2013-03-14 Siemens AG 2013 All rights reserved Siemens AG Healthcare Sector, Henkestr. 127, D-91050 Erlangen,
MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION. Definitions of Eye Examinations. Federal Government Definition
MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION Craig Thomas, O.D. 3900 West Wheatland Road Dallas, Texas 75237 972-780-7199 [email protected] Definitions of Eye Examinations Optometry
The light. Light (normally spreads out straight... ... and into all directions. Refraction of light
The light Light (normally spreads out straight...... and into all directions. Refraction of light But when a light ray passes from air into glas or water (or another transparent medium), it gets refracted
Dx MM DICOM 3.0 Conformance Statement
Dx MM DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet
A PACS-Aware DICOM Image Object
Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors
Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors Diego Betancourt and Carlos del Río Antenna Group, Public University of Navarra, Campus
AGFA HEALTHCARE DICOM Conformance Statement
Page 1 of 79 AGFA HEALTHCARE DICOM Conformance Statement IMPAX 6.5 Solution Document No. 001310 Revision: 1.1 When printed, this is NOT a controlled document. Page 2 of 79 Document Information Service-related
Getting Ready for ICD-10. Dianna Hoskins, OCS Cincinnati Eye Institute
Dianna Hoskins, OCS Cincinnati Eye Institute Chart Documentation: Will your documentation stand up to ICD-10? Do you always mark which eye, severity or status of the disease (chronic or acute), site, etiology
DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546
DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546 SecurView DX DICOM Conformance Statement Part Number MAN-00546 Revision 001 For Software version 5-X Service
DICOM CONFORMANCE STATEMENT
Technical Publications Revision 3 Reporting Tool 2.7 DICOM CONFORMANCE STATEMENT Copyright 2005-2010 by General Electric Co. Do not duplicate Page 1 of 34 REVISION HISTORY Revision Date Reason for Change
The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan
The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan Margie V. Wilson, COMT Chief Clinical Supervisor UCSD Shiley Eye Center Thanks, Carol! Unfortunately. I have not financial
DICOM Conformance Statement
Philips Medical Systems DICOM Conformance Statement Integris Systems with High Speed DICOM Image Interface MCV 2974 MCV 3621 Cardiac DICOM XA MCV 3761 Vascular DICOM XA MCV 3031 DICOM RIS Interface and
Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda
Slit Skiascopic-guided Ablation Using the Nidek Laser Scott MacRae, MD; Masanao Fujieda ABSTRACT PURPOSE: To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with
Automatic and Objective Measurement of Residual Stress and Cord in Glass
Automatic and Objective Measurement of Residual Stress and Cord in Glass GlassTrend - ICG TC15/21 Seminar SENSORS AND PROCESS CONTROL 13-14 October 2015, Eindhoven Henning Katte, ilis gmbh copyright ilis
Trends in Ophthalmology a Market Perspective. Matthias Karl, Michael Kempe
Trends in Ophthalmology a Market Perspective Matthias Karl, Michael Kempe 30.04.2013 Agenda 1 2 3 4 Role of Optical Technologies in Ophthalmology Demands of the Market - Trends in the Application Implications
DICOM Conformance Statement FORUM
DICOM Conformance Statement FORUM Version 3.1 Carl Zeiss Meditec AG Goeschwitzerstraße 51-52 07745 Jena Germany www.meditec.zeiss.com Document: DICOM Conformance Statement_FORUM_3.1.doc Page 1 of 25 1
Digital Imaging and Communications in Medicine (DICOM) Supplement 66: Catheterization Lab Structured Reports
Digital Imaging and Communications in Medicine (DICOM) Supplement 66: Catheterization Lab Structured Reports Prepared by: DICOM Standards Committee, Working Group 1 Cardiovascular Information 1300 N. 17
CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH
CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology
LIST OF CONTENTS CHAPTER CONTENT PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK
vii LIST OF CONTENTS CHAPTER CONTENT PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK LIST OF CONTENTS LIST OF TABLES LIST OF FIGURES LIST OF NOTATIONS LIST OF ABBREVIATIONS LIST OF APPENDICES
NC DIVISION OF SERVICES FOR THE BLIND POLICIES AND PROCEDURES VOCATIONAL REHABILITATION
NC DIVISION OF SERVICES FOR THE BLIND POLICIES AND PROCEDURES VOCATIONAL REHABILITATION Section: E Revision History Revised 01/97; 05/03; 02/08; 04/08; 03/09; 05/09; 12/09; 01/11; 12/14 An individual is
LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes
LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West
DICOM CONFORMANCE STATEMENT
Technical Publications Revision 2 Reporting Tool DICOM CONFORMANCE STATEMENT Copyright 2005-2009 by General Electric Co. Do not duplicate Page 1 of 31 REVISION HISTORY Revision Date Reason for Change A
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Converting the DICOM Presentation State to AIM Version 3.0
Converting the DICOM Presentation State to AIM Version 3.0 Development Team(s) Development Technical Documentation Program Management Pattanasak Mongkolwat Pattanasak Mongkolwat Peter Yan Vladimir Kleper
DICOM CONFORMANCE STATEMENT
g GE Healthcare Technical Publications Direction 2067192-001 Revision 4 Universal Viewer* Web Client Version 5.0 SP5 * Trademark of General Electric Company Copyright 2014 by General Electric Co. Do not
Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes
Page i 5 Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes 10 15 20 Prepared by: Working Group 6 DICOM Standards Committee, Working Group 6 1300 N.
IHE Radiology Technical Framework Supplement. Web-based Image Capture (WIC) Draft for Public Comment
Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Web-based Image Capture (WIC) 15 Draft for Public Comment 20 Date: February 19, 2015 Author: IHE Radiology Technical
Grading staining: Oxford Schema The scheme is used to estimate surface damage in dry eye.
DEWS DRY EYE: DIAGNOSTIC TEST TEMPLATE RAPPORTEUR A.J.Bron 21 st Oct 2004 TEST TO DIAGNOSE VERSION of TEST DESCRIPTION NATURE of STUDY CONDUCT of TESTS Grading staining: Oxford Schema The scheme is used
Digital Image Fundamentals. Selim Aksoy Department of Computer Engineering Bilkent University [email protected]
Digital Image Fundamentals Selim Aksoy Department of Computer Engineering Bilkent University [email protected] Imaging process Light reaches surfaces in 3D. Surfaces reflect. Sensor element receives
Alexandria Fairfax Sterling Leesburg 703-931-9100 703-573-8080 703-430-4400 703-858-3170
DIABETIC RETINOPATHY www.theeyecenter.com This pamphlet has been written to help people with diabetic retinopathy and their families and friends better understand the disease. It describes the cause, symptoms,
DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0
DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0 DICOM Conformance Statement, Ziostation 2.0 1 Copyright 2006-2011, Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW... 5 0.2
Digital Imaging for Ophthalmology
ANKA Systems, Inc. Digital Imaging for Ophthalmology Contents 02 Company Overview 03 EyeRoute Products Overview 04 EyeRoute Application 08 EyeRoute Components Digital Imaging for Ophthalmology Who We Are
DICOM Conformance Statement
Date: 2014-12-18 DICOM Conformance Statement CIRRUS TM HD-OCT 5000 and 500 Instrument Version 7.5/8.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_CIRRUS_7.5_8.0.Docx
DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0
DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0 DICOM Conformance Statement, ZioCube 1.0 1 Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW...5 0.2 FUNCTIONAL DEFINITION OF
ICD-10 Codes for Optometry. Eric Botts, OD Macomb, IL [email protected]
ICD-10 Codes for Optometry Eric Botts, OD Macomb, IL [email protected] Disclosures I am a member of Speakers Bureau for Zeissmeditec and ALCON but have no financial interest in these companies.
DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT
DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT NOTICE The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release.
Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners
Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners Background The lateral response artifact (LRA) in radiochromic film images from flatbed scanners was first pointed
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
Color holographic 3D display unit with aperture field division
Color holographic 3D display unit with aperture field division Weronika Zaperty, Tomasz Kozacki, Malgorzata Kujawinska, Grzegorz Finke Photonics Engineering Division, Faculty of Mechatronics Warsaw University
Extracting, Storing And Viewing The Data From Dicom Files
Extracting, Storing And Viewing The Data From Dicom Files L. Stanescu, D.D Burdescu, A. Ion, A. Caldare, E. Georgescu University of Kraiova, Romania Faculty of Control Computers and Electronics www.software.ucv.ro/en.
INFORMATION ON DARC: THE DIGITAL ANGIOGRAPHY READING CENTER
INFORMATION ON DARC: THE DIGITAL ANGIOGRAPHY READING CENTER 1 DIGITAL ANGIOGRAPHY READING CENTER Chairman/Medical Director Jason S. Slakter, M.D. Clinical Professor of Ophthalmology NYU School of Medicine
ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement
ONIS 2.0 DICOM CLIENT DICOM 3 Conformance statement Table of Contents 0 Introduction...4 0.1 Scope...4 0.2 Standards...4 0.3 Intended Audience...4 0.4 Important Remarks...4 0.5 Definitions...4 1 Implementation
The Information Processing model
The Information Processing model A model for understanding human cognition. 1 from: Wickens, Lee, Liu, & Becker (2004) An Introduction to Human Factors Engineering. p. 122 Assumptions in the IP model Each
Understanding Network Video Security Systems
Understanding Network Video Security Systems Chris Adesanya Panasonic System Solutions Company [email protected] Introduction and Overview This session will provide vendor neutral introduction
INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING
INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING Helmut Jorke, Markus Fritz INFITEC GmbH, Lise-Meitner-Straße 9, 89081 Ulm [email protected] Phone +49 731 550299 56 Fax _
GE PACS Conformance Statement for DICOM v3.0
g GE Medical Systems Technical Publications IIS P/N 4361668 Revision 01 GE PACS Conformance Statement for DICOM v3.0 Copyright 1998 By General Electric Company g GE Medical Systems GE Medical Systems,
Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation
Roche Applied Science Technical Note No. LC 19/2004 Purpose of this Note Color The LightCycler System is able to simultaneously detect and analyze more than one color in each capillary. Due to overlap
~Contributing to Eye Health~
~Contributing to Eye Health~ 26 Eye Care Market Trends FY2007 Retinal Camera market forecasts by eye disease FY 2010 Auto Keratorefractometer Retina 160 Refraction Retina 200 Refraction Auto Lens Edger
How to Use a Smartphone Camera for Ocular Photography in the Horse
How to Use a Smartphone Camera for Ocular Photography in the Horse Dennis E. Brooks, DVM, PhD, DACVO Author s address: University of Florida, College of Veterinary Medicine, 2015 SW 16th Avenue, Gainesville,
CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
Experiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments
Lecture 17. Image formation Ray tracing Calculation Lenses Convex Concave Mirrors Convex Concave Optical instruments Image formation Laws of refraction and reflection can be used to explain how lenses
SafetyScan Lens. User Manual
SafetyScan Lens User Manual Contents Introduction 2 Lens selection 3 Beam quality parameter Using the tables Use with lasers whose M 2 is 1.2 4 Use with lasers whose M 2 is 3.0 5 Use with lasers whose
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
The HIPPA Act of 1996 BILLING & CODING THE MEDICAL EYE EXAMINATION. Federal Government Definition. Optometry School Definition 7/20/2011
BILLING & CODING THE MEDICAL EYE EXAMINATION Craig Thomas, O.D. 3900 West Wheatland Road Dallas, Texas 75237 972-780-7199 [email protected] The HIPPA Act of 1996 Result of law is to establish national standards
Optical Communications
Optical Communications Telecommunication Engineering School of Engineering University of Rome La Sapienza Rome, Italy 2005-2006 Lecture #2, May 2 2006 The Optical Communication System BLOCK DIAGRAM OF
Measure of Confidence. Glaucoma Module Premium Edition
Measure of Confidence Glaucoma Module Premium Edition The Changing Face of Glaucoma Practice Literature 1 Leske et al., Arch Ophthalmol 1997; 115:1051-1057 2 Doughty et al., Surv Ophthalmol 2000; 44:367-408
EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS MODULE 1: CAMERA SYSTEMS & LIGHT THEORY (37)
EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS The exam will cover evidence photography involving crime scenes, fire scenes, accident scenes, aircraft incident scenes, surveillances and hazardous materials scenes.
IMAGE ASSISTANT: OPHTHALMOLOGY
IMAGE ASSISTANT: OPHTHALMOLOGY Summary: The Image Assistant has been developed to provide medical doctors with a software tool to search, display, edit and use medical illustrations of their own specialty,
Digital Imaging and Communications in Medicine (DICOM) Part 6: Data Dictionary
Digital Imaging and Communications in Medicine (DICOM) Part 6: Data Dictionary Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright 2003
How To Connect Ifa Dicom To An Ophthalmology System
High Level Health IT (HIT) Standards for Ophthalmologists worldwide DICOM : the comprehensive ifa Solutions (Digital Imaging and Communication in Medicine) 1 1 2 3 4 5 6 7 8 Overview Introduction and DICOM
Hologic Physician s Viewer 7.0 DICOM Conformance Statement
Hologic Physician s Viewer 7.0 DICOM Conformance Statement MAN-02386 REV 001 Page 1 of 32 1. Conformance Statement Overview This document is the DICOM Conformance Statement for Hologic Physician s Viewer,
Top Medicare Audit problems. Retinal Imaging Technology. Optometric Medical Coding. Unilateral codes. Modifiers
Top Medicare Audit problems Evaluation, Diagnosis, Coding and Reimbursement Associated with Medical Vitreo-Retinal Conditions Kim Castleberry, OD Plano Eye Associates Patient/staff initiated billing complaints!
Do You STILL Need Technology? DO YOU STILL TECHNOLOGY? The Challenges in 2013. The Challenges in 2013. FEC s Production Reports 2012
DO YOU STILL TECHNOLOGY? Craig Thomas, O.D. 3900 West Wheatland Road Dallas, Texas 75237 (972) 780-7199 [email protected] NEED Do You STILL Need Technology? Why do we need to buy technology like a $10,000
Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm
Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and