SYNSPEC GC s ALPHA 115 and ALPHA 116

Size: px
Start display at page:

Download "SYNSPEC GC s ALPHA 115 and ALPHA 116"

Transcription

1 SYNSPEC GC s ALPHA 115 and ALPHA 116 Methane/TotalNonMethaneHydroCarbons Operator manual Version January 2010 Synspec b.v. De Deimten AV Groningen Nederland info@synspec.nl

2

3 CONTENTS CONTENTS... 1 Preface Introduction Safety notice General requirements What s in the box Synspec Alpha 115 at a glance Software Hardware Communication Data handling Alarm functions and password Operating Principle of the ALPHA Collecting the sample Analysing of methane Analysing of total non methane hydrocarbons For the operator Actual data Language and help Actual value Trend Status Recalibrate Calibration trend View alarm log Restart FID Chromatogram Datafile SELECT VIEW ITEMS SELECT SCREEN ELEMENTS ADJUST DETECTOR Y-AXIS OFFSET Attenuation : Chromatogram scale, date and cycle time : Load datafile : Directory structure Index

4 Preface The purpose of this manual is to guide the operator in operating the Alpha 115 and the Alpha 116. Read this manual first before you start to work with this instrument. Contact your service engineer or expert if you have questions about this instrument. Keep this manual to use it in daily practice. 2

5 1. Introduction Synspec Alpha is an on-line gas chromatograph for measuring hydrocarbons in ambient air on behalf of environment and industry. The measuring principle is true gas chromatography and the equipment is designed for field work. Synspec Alpha 115 and 116 are compact gas chromatographs for measuring Methane and sum of total non-methane hydrocarbons in ambient air. Standard analyses time is 3 min (180 sec). The difference between the Synspec Alpha 115 and the Synspec Alpha 116 is the size of the loop and thus the detection limit. With packed column and FID detector the Alpha 115 can detect from to 0,1 ppm to 1000 ppm Methane and from 0,05 ppm to 100 ppm total non methane hydrocarbons. The Alpha 116 has a minimum detection limit of 1 ppm for methane and 1 ppm for total non methane. The reproducibility of the results is 1% of F(ull) S(cale). Both types have an internal calibration switch for a fully automated calibration with zero air and span gas. All the connections to the GC are 1/8 inch Swagelock connectors. The GC has an internal Pentium computer with hard disk for storage of measurement results and 6 colour touch screen. The computer runs on Windows XPe and has the Synspec Alpha software pre-installed. The GC can be controlled by using the touch screen, via keyboard and mouse, or remotely via RS 232/ Ethernet/ modem. The GC Alpha software has three user levels : 1. Operator level. For the operator who looks at the results of the measurements and can start a standard calibration. 2. Service level. For the technician to adapt the machine for simple adaptations like changing the calibration gas bottle and the conditions for calibration. 3. Expert level. For the distributor or expert to install the machine, adapt all the settings, adapt the machine and software, do maintenance and trouble shooting. In this setting the principle and functioning of the system can really be altered. Which is not possible in levels 1 and 2. 3

6 1.1 Safety notice WARNING: The instrument is to be used by trained personnel ONLY. Always disconnect the gas and power supply before opening the instrument. Beware of electrostatic shocks to the internal computer. Do not drop metal parts in it. Use appropriate tools for maintenance. Please note that the following risks have to be considered when working with the instrument: Hydrogen and air at a pressure between 0.5 and 5 bar will be connected to the instrument. Personnel must be trained in safety issues of gasses in general and these gases specifically before working with these gases. The instrument works with a 230Vac or 110 Vac power supply. NOTICE: Inspect the instrument for transport damage upon receiving. If you see any damages please do not switch on the analyser. In case of damage contact your supplier within 8 days after receiving the instrument. Do not move an instrument when the internal computer is working to avoid damage of a hard disk. Copy data from hard disk on a regular base. Otherwise the data can be lost which is at your own risk. If you have questions about running the instrument, please contact your local supplier or Synspec BV. (Tel , fax , info@synspec.nl). If you modify the analyser the warranty is void and correct measuring is no longer guaranteed. 4

7 1.2 General requirements 1. The instrument has to be placed in an air-conditioned room for operating at a stable temperature. 2. A space of standard H(eight)U(nit) from the bottom and 1 standard HU from the top has to be kept free for ventilating the system. Do not forget to reserve a place for the keyboard and mouse, preferably a board on slides, which can be 10 to 50 cm below the GC. 3. Power demand : Standard 230 Vac, 200 VA. 4. Room temperature : Between 5 and 40 o C. 5. Relative humidity : Must be %. 6. Gases a. Zero air as carrier gas, for the FID and for a zero span check (See Fig. 1.1). The quality should be 5.0 (99,999% pure) dry and clean at a pressure of 2,5 bar (38 PSI) and if it is used as a zero span check it should also be free of methane. Because the GC normally use 150 ml/min a standard gas bottle of 10 liter at 200 bar will only last for around 5,5 days. Therefore we recommend a zeroair generator (Fig. 1.1a). b. Hydrogen as fuel for the FID. Quality 5 (99,999% pure) at a pressure of 2,5 bar (38 PSI) c. Span gas we normally use a bottle of 1-2 ppm methane and ppb Propane in air and set the pressure at 1 bar. Left on top of the GC, above the touch screen you find the pressure regulators (Fig. 1.1). Fig. 1.1 Pressure regulators in the GC Pressure settings for hydrogen, zero air for FID and zero air for carrier (left to right). All recommended settings are marked. 5

8 Fig. 1.1a Zero air and hydrogen generator 7. Gas couplings All couplings to the instrument must be made in 1/8 Swagelok-compatible, for the gas supply in bronze, for the sample in stainless steel. 8. Pressure regulators (See Fig. 1.2). These must be of gaschromatographical quality. That means that they must be dust free and may not absorb or emit hydrocarbons. For air this is at least a nickel-plated bronze regulator with steel membrane, for bottles with maximal pressure 200 bar, range of the regulator 0-4 or 0-10 bar. For calibrating gases a stainless steel regulator with high quality steel membrane is preferred. Fig. 1.2 Stainless steel regulator 9. Dust filter for sample lines : Material : Teflon filter membrane of 5 micron. Alternatively disposable nylon filters with glass frit or Teflon filters can be used. 10. Sample tubing :Clean inert tubing from PTFE (Teflon), FEP or stainless steel, even for short connecting pieces. Do not use the same tubing for taking ambient air samples and calibration samples. Use two tubing systems, that are only connected 5-15 cm before the sampling port. Approval : CE approval for EMC conformity : EN , EN and NEN The serial number of the Alpha is printed on a sticker in the middle of the rear side. 6

9 1.3 What s in the box Fig. 1.3 Synspec Alpha keyboard + mouse + extension cables + touch screen pen Power cable Memory stick (USB) UTP cross cable Toolset and connectors (green) Documents : manual, AED α-list. Restriction Software license (on a sticker in the GC) 7

10 1.4 Synspec Alpha 115 at a glance Visual appearance and connections Fig. 1.4 Front 1. LCD-touch screen 2. 2 USB ports 3. Error indication LED 4. Idle/Running indication LED 5. Power switch Fig. 1.5 Rear 1. Mains 230 Vac/ 50 Hz Fuse 2A 6. Carrier gas 2. Digital in/output inlet 11. Com VGA (monitor) 3. Analogue output 4. Analogue input 5. Pump out 7. Sample inlet 8. Spangas inlet 9. Zero Air inlet 10. Hydrogen inlet 13. LAN (local USB 2.0 area network) ports 15. Kb./MS (keyboard/mouse) 8

11 Fig. 1.6 Connector overview For adaption with a restriction, see extended calibration, description of the options. 1.5 Software The alpha software is pre-installed on the GC and runs under windows XP embedded ( XPe). All the program settings are already installed and checked in our laboratory. Therefore the normal time to install the GC is minimal when all the requirements as described on par. 1.2 are met. The software is user friendly and has three levels: operator level, service level and expert level. 1.6 Hardware Internal computer with all the required software to run this GC Hard disk to store the program, measurement data and all the chromatograms LCD touch screen to see the results of the measurements, the status of the equipment and to move through the programs 1.7 Communication With the GC Alpha there are several ways to communicate with the GC Digital out en inputs. The GC Alpha has seven digital output ports, and 4 digital inputs. These are freely programmable and can be used for the linking up of external equipment (external integrator or calibrator) or to react to external signals, like a remote start or a pressure switch. Analogue outputs and inputs. The GC Alpha has 4 analogue outputs to send a signal to an external datalogger. The Alpha also has 4 analogue inputs to use the computer of the GC alpha as a simple datalogger. USB. The GC Alpha has two USB connections at the front and two at the rear. These can be used for copying data or to attach external computer accessories. RS232. The GC Alpha has two comports that can be used for a RS232 connection. Over the RS232 data can be transmitted to a datalogger. 9

12 Ethernet connection. By using the Ethernet connection the software can be controlled from everywhere in the network, if the GC Alpha is attached to the internet the machine can even be controlled over the internet, by using programs like team viewer, PC-anywhere and gotomypc. Analogue outputs Analogue inputs Digital outputs RS-232- communication RS-232 modem, internet or ethernet (programs:pc Anywhere, VNC viewer and team viewer have been tested) USB connection Data transfer Status information Instrument control Concentration values will be transmitted Can be used to read in data from other instruments no Concentration values will be transmitted Yes, all data can be copied. Speed depends on modem and phone line, internet or Ethernet connection Can be used to copy data from the hard disk to zip drive, memory stick, CD-writeable etc. No no Yes, all set parameters in the digital communication protocol will be transmitted. Yes, all set parameters in the communication protocol will be transmitted. Yes, as the GC screen can be seen no no Limited: some actions, like runstart, or start calibration can be set. Limited: some actions, like runstart, or start calibration can be set. Full software control possible Relay. The GC alpha has one relay which can be used for example to switch on an alarm signal when a certain concentration is reached Data handling The result of each measurement is stored in an monthly overview file and can be sent to a datalogger by using the analogue or over RS232. All the raw data (original chromatograms) are stored on the hard disk. In this way measurements can be checked and if the settings were not correct you can change it and the raw data (chromatograms) can be reprocessed Alarm functions and password no no 10

13 The GC Alpha is adapted for use as early-warning system for toxic compounds. Levels for low and high alarm can be set. Alarms can be given over modem, or over digital outputs. The GC can also be provided with a buzzer or lamp for an alarm on site. The GC Alpha can be protected by password. 11

14 2. Operating Principle of the ALPHA 115 The measurements are based upon a TRUE GAS CHROMATOGRAPHIC SEPARATION. This is done to avoid problems with catalytic functioning as often occurs with systems without the GC column resulting in inaccurate measurements. Because it is a real gas chromatograph it contains a a loop ( to collect a sample), a compact oven ( to heat up the column), a column (to separate methane from total non-methane hydrocarbons) and an FID ( Flame Ionisation Detector). Fig. 2.1 FID Fig. 2.2 Drawing of FID principle Principle: In a flame, oxygen and hydrogen are burned. When in a hydrogen flame other molecules pass, these will burn also and increase the amount of ions. The ions generated by the flame are attracted to the positive side of an electrical field in the detector cell. The electrical current in the detector cell changes, this change is measured and has a direct correlation with the concentration. 12

15 For our way of measuring we use a 10-port valve to switch between the different phases of the cycle. The use of a 10-port valve is mandatory for the principle of our measurements. A single measurement can be split into three different phases: 2.1 Collecting the sample Fig. 2.3 Phase one, the sample loop is filled The sample is pulled by an internal sample pump from the sample in through the sample loop to the sample out collecting a volume of sample that is equal to the volume inside of the sample loop. Than 10-port valve switches to reach phase 2. 13

16 2.2 Analysing of methane Fig. 2.4 Phase two, detection and analysing of methane The carrier gas carries the volume of sample from the sample loop to the column and to the FID. The column retains the TNMHC and the methane is passing through the column. So in this phase only the methane is detected. For the burning of the FID the hydrogen and the zero air also flow to the detector. To go phase 3 the 10-port valve is again switched. 14

17 2.3 Analysing of total non methane hydrocarbons Fig. 2.5 Phase 3, detection and analysing of total non methane hydrocarbons (TNMHC) The flow of carrier gas over the column is now, in the opposite direction ( backflush) in comparison to phase 2, going to the FID. GC columns normally separate the different hydrocarbons, by using the backflush principle we regroup these different hydrocarbons resulting in only one peak for the TNMHC. If Phase 3 is compared with phase 1 it is clear that both phases can be run at the same time. Meaning that a sample can be collected while the TNMHC is being analysed. This saves time and results in shorter cycle times, thus more measurements per time unit. Fig port valve, 2. FID, 3. Column oven 15

18 3. For the operator When all connectors are connected the right way and the GC is started, then you will see the the actual data screen, see next picture (Fig. 3.1) : 3.1 Actual data Fig. 3.1 Actual data (operator level) For a better explanation in this manual numbers in red are placed on the screen picture Language and help Actual data item 1 (Fig. 3.1) ITEMS : Above this number you see the name of this screen thus you are now looking at the GCAlpha-Actual data screen. The items Language and Help are not activated yet. The language is English and for help after you have read this manual thoroughly, you can call your service engineer or expert Actual value Actual data item 2 (Fig. 3.1) ACTUAL VALUE : Here you see the Actual value for CH4 (methane) i.e v-ppb (volume-parts per billion) Below this you see the Actual value of TNMHC (TotalNonMethaneHydroCarbons) i.e v-ppb Trend 16

19 Actual data item 3 (Fig. 3.1) TREND : Below Trend you see a little picture of a graph made of measurement values from the last 50 measurements of CH4. By clicking on this little picture you get Fig. 3.2 i.e. : the last 50 measurement data of methane (CH4). Under Actual value you read the value v-ppb, this is the last measured value. On the trend list is this the value number 1 produced on 4/ The other values have older dates and so number 50 have the oldest measurement date. On this list you also see the average value of the 50 measurement values i.e v-ppb. With the same principle as for CH4, below the little picture of the CH4-graph you see of a graph made of measurement values from the last 50 measurements of TNMHC. By clicking on this little picture you get Fig. 3.3 i.e. the last 50 measurement data of TNMHC. The Actual value of v-ppb is the last measured value. On the trend list is this the value number 1 produced on the same date 4/ The average value of TNMHC is here v-ppb. Fig. 3.2 last 50 measurementsdata of CH4 Fig. 3.3 Last 50 measurementsdata of TNMHC So when after this you make again a measurement, the values of this measurement will be the last measured values and will be placed as the new number 1 on the trend list. The previous number 1 on the list with the values v-ppb for CH4 and v-ppb for TNMHC are then placed on number 2 on the trend list and so on. The former number 50 on the list disappears and former number 49 on the list is now the new number 50. Of course the Average values will change also. When you click on OK on both of the trend lists you get back to the Actual data screen Status Actual data item 4 (Fig. 3.1) STATUS : At the Status you can see what the GC is busy with at this moment. On the screen you read Running Analizing, this means that the GC now is busy with analyzing. Other possible Status messages on screen are : Running waiting to start (The waiting time between 2 runs), Running injecting (The GC is busy with sample injection), Power up check" (The GC is checking the power) and Error (Something wrong is happened before, during or after a run). 17

20 3.1.5 Recalibrate Actual data item 5 (Fig. 3.1) RECALIBRATE : After clicking on Recalibrate, you are going to start a (Re)calibration. The status message of calibration is changed in Waiting to start. If you do want to start a (re)calibration, please check first if the sample tubing is attached to the spangas inlet. There are 3 possibilities that you are going to see as status message of calibration : a. Waiting to start, b. Running and c. Idle. c. Idle, means out of specifications or either the deviation from the last one is too large, or that the values of the repetitions are too much different Calibration trend Actual data item 6 (Fig. 3.1) CALIBRATION TREND : By clicking on the surface with number 6, calibration trend,you get the calibration trend for methane (Fig. 3.4) and on this trend you see 2 radiobuttons, one for CH4 (methane) which is tapped and one for TNMHC and by tapping the TNMHC button you get the TNMHC trend (Fig.3.5). Fig. 3.4 calibration trend of CH4 Fig. 3.5 calibration trend of TNMHC Fig. 3.6 calibration trend of CH4 not yet done Fig. 3.7 calibration trend of TNMHC not yet done The trend learns us to see how stable the calibration is. The lesser the graph goes up and down the more stable the calibration is. But when you see one straight line in the middle, this means that there is no calibration yet (Figures 3.6 and 3.7). The graph is a good help to follow the calibration in sensitivity and or stability. By clicking on close you return to the Actual data screen View alarm log 18

21 Actual data item 7 (Fig. 3.1) VIEW ALARM LOG : By clicking on View alarm log, you get an overview of the history of all the alarms (Fig. 3.8) By scrolling with the mouse you will find the last given alarm at the end of the list. On the Actual data screen (Fig. 3.1) the status message of the system alarm shows No error, this means nothing is going wrong. Fig. 3.8 Dialog Restart FID Actual data item 8 (Fig. 3.1) RESTART FID : By clicking on this, The FID will start automatically. The FID detector in Actual data shows if the FID is running properly. The temperature normally should be between 80 and 150 o C. : On the Actual data screen (Fig. 3.1) the status message of the detector is OK, temperature 99. This means the flame is burning and detector temperature is 99 C and thus OK Chromatogram Actual data item 9 (Fig. 3.1) CHROMATOGRAM : By clicking on Chromatogram the Datafile screen appears, and then you click on Options and you see Fig On this screen you will see the chromatogram, the graph with the peaks of CH4 and TNMHC when you load a datafile. All datafiles, measurement, calibration - and validation files are saved in directories. These directories are joined in a structure, the GC Alpha directory structure (Fig. 3.18). 19

22 See datafile item 6 how to load a datafile after you have clicked on Load datafile. 3.2 Datafile Fig. 3.9 Datafile (operator level) Datafile item 1 (Fig. 3.9) : Here we have 3 items, Options, Language and Help. The Options are : SELECT VIEW ITEMS : When you click on Select view items, fig appears : Fig Options 20

23 The way of setting for additional info on the chromatogram happens by clicking in the empty square(s) next to the item concerns and then by clicking OK. Here you see that Oventemperature and pump are marked. By clicking on Chromatogram (See Fig. 3.1) again you will see Fig The green tube with a blue square in it shows the functioning of the pump and the red irregular running line presents the oventemperature. Other options are not applicable or activated. Click Cancel means you don t want to change anything and go back to the previous screen. OK and Cancel are not mentioned again in this manual. Fig red line is oventemperature, the blue square is the pump SELECT SCREEN ELEMENTS : Click on Select screen elements and you get Fig Fig Select screen elements Fig Datafile with all screen elements With select screen elements you can choose to see : On Fig all the screen elements are marked and these elements you can see on the chromatogram on Fig

24 1. Peak windows : This is a window set over the peak to make sure the whole chromatogram is integrated and also important for setting retention time lock. The setting method for this is for the expert. 2. Retention time : The time from injecting to showing a peak. This should be always (almost) the same. 3. Integration values : An integration value is the surface area of a peak, important for determining the concentration of the compound. 4. Calculated peakheights : Important for the integration of the chromatogram. 5. Horizontal axis seconds : With this you set the chromatogram scale in seconds ADJUST DETECTOR Y-AXIS OFFSET : Click on Adjust detector Y-axis offset, the next screen appears. Fig Y-axis offset adjust With Y-axis offset adjust you can set the axis higher in case the baseline disappears below the chromatogram scale. Sometimes you see a chromatogram disappears with baseline under zero. This you can correct by adjusting the Y-axis offset, choosing a fit value in the block next to FID Detector (Fig. 3.14) Attenuation : Datafile item 2 (Fig. 3.9) : In Figures 3.9 and 3.14a in close-up you see how the chromatogram can be attenuated. Click on Previous, you see the previous value, click on Next you see the next value. When the peak is very small you can make it bigger, but the rest of the peaks becomes also bigger. For example : To attenuate the chromatogram to 10x, click on 1 and then on 10 and so on. The attenuating of the chromatogram has totally no influence on the measurement results. Standard setting is 4x10 (See Fig. 3.15). Other setting is shown on Fig Fig. 3.14a detail from fig

25 Fig att. 4x10 Fig att. 4x Chromatogram scale, date and cycle time : Datafile item 3 (Fig. 3.9) : This is the chromatogram scale where above the chromatogram shows. Fig detail from fig. 3.9 Datafile item 4 (Fig. 3.9) : In Fig. 3.9 and Fig in detail the left you see a little box with the value 0, this is where you read the minutes and seconds of the scale. When you set the scale in 10% the total minutes/seconds is and so on. Next to this you see a little scale in blue/grey from 0 to more than 30. By clicking in this part you can look at the chromatogram further on the scale. When you click at the end of the scale the red vertical line moves to the end and the scale moves to the end to 60 at 100%. At the last part you can set the scale in 100%, 50%, 25% and 10% of the scale by clicking on the value you want. Datafile item 5 (Fig. 3.9) : Here you see the date, time and cycle time (Fig. 3.9) Load datafile : Datafile item 6 (Fig. 3.9) : Click on the datafile screen on Load datafile to load a datafile of a measurement, calibration or validation (Fig. 3.9). To choose the file you want, you have to follow the directory structure (See Fig. 3.18). 23

26 3.3 Directory structure 24

27 Fig Directory structure GCALPHA 115 Datafile is used to recall files, data files (D), calibration files (C) or validation files (V). Choose the directory for the correct month (for instance D_0903 for March 2009). The chromatograms are saved in month-directories, with day-subdirectories, with a filename derived from the measurement time in days, hours, minutes, prefixed by a m: m_ bin. The chromatogram appears if you double-click a file. The scale in the x and the y-axis is the same as in the chromatogram that is being measured. The rundat.txt file (RDyymm.TXT) down below Fig and Fig is a summary of all measurements per month with many information like date, time, concentration and integration value (Area). Fig rundat.txt file Explanation of the rundat.txt file (Fig. 3.19) : 1. Code N : Normal data or data from normal measurements. Code V : Validation data or data from validation measurements. Code C : Calibration data or data from calibration measurements. 2. Date : Date of measuring. 3. Time : Time of measuring. 4. Sample 1 5. Area-1 : Integration value of CH4. 25

28 6. Conc-1 : Concentration of methane (CH4) in v-ppb 7. Reti-1 : Retention time of CH4. 8. Conc-2 : Concentration of total non methane hydrocarbons (TNMHC) in v-ppb. 9. Area-2 : Integration value of TNMHC. 10. Reti-2 : Retention time of TNMHC. You can move freely between the modes actual data and load datafile. Actual data item 10 (Fig. 3.1) CLOSE : To close the program (Fig. 3.1). Actual data item 11 (Fig. 3.1) LOGIN : The Login for the service level and the expert level (only for the technician and distributor). 26

29 Index 1 10-port valve 13, 14, 15, 16 A Actual data 17, 18, 19, 20, 27 Actual value 17, 18 ADJUST DETECTOR Y-AXIS OFFSET 23 AED α-list 7 ambient air 3, 7 Analog inputs 10 Analog outputs 10 B bronze See gas couplings C Calculated peakheights 23 calibration 3, 7, 9, 10, 19, 20, 24, 26 CALIBRATION TREND 19 Carrier gas 9 Chromatogram 20, 22 D Datafile 20, 21, 22, 23, 24, 26 digital in- and/or output ports 10 Digital outputs 10 E early-warning system 11 F FEP 7 filter membrane 7 G Gas couplings 6 glass frit 7 H Help 17, 21 Horizontal axis seconds 23 I integration value 23, 26 Integration values 23 ITEMS 17, 21 L Language 17, 21 low and high alarm 11 M methane 3, 5, 13, 14, 15, 16, 17, 18, 19, 27 N nickel-plated bronze regulator 6 O Options 20, 21 Oventemperature 22 P Peak windows 23 Pressure regulators 6 Pressure regulators in the GC 6 PTFE (Teflon) 7 R RESTART FID 20 Retention time 23, 27 RS-232 modem and PC Anywhere 10 RS-232-communication 10 S sample 6, 7, 13, 14, 15, 16, 18, 19 Sample tubing 7 SELECT SCREEN ELEMENTS 22 software license 7 stainless steel 7, See gas couplings stainless steel regulator 6 status message 19, 20 Swagelok-compatible 6 27

30 T Teflon 7 toxic compounds 11 U USB connection 11 V VIEW ALARM LOG 20 W warranty 4 Z Zero air 5 28

On-line Dissolved Gas Analysis

On-line Dissolved Gas Analysis On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

This document is intended to make you familiar with the ServersCheck Monitoring Appliance ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other

More information

EnAlgae SOP: Biogas analysis

EnAlgae SOP: Biogas analysis Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 3.3. PREPARATION OF MEASUREMENT... 3 4. PROCEDURE... 4 4.1. SAMPLE MEASUREMENT...

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

Process Instrumentation

Process Instrumentation Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

QUICK INSTALLATION GUIDE. VEBAR Battman Monitoring Software

QUICK INSTALLATION GUIDE. VEBAR Battman Monitoring Software QUICK INSTALLATION GUIDE VEBAR Battman Monitoring Software For Microsoft operating systems XP, VISTA, WINDOWS 7 For Linux OS install, please contact customer service and refer to document: VEBAR Software

More information

CHROMOCTANE O N LINE ANALYZER

CHROMOCTANE O N LINE ANALYZER GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

Manual. Sealer Monitor Software. Version 0.10.7

Manual. Sealer Monitor Software. Version 0.10.7 Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3

More information

GX-2009 Data Logger Management Program Operator s Manual

GX-2009 Data Logger Management Program Operator s Manual GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: C Released: 3/19/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by

More information

Monitoring Network DMN

Monitoring Network DMN Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...

More information

CRE Monitor Instructions Manual

CRE Monitor Instructions Manual CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility

More information

Dyeing Programmer DP - 01

Dyeing Programmer DP - 01 Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:

More information

SPC-1. Single Point Controller. Operation Manual

SPC-1. Single Point Controller. Operation Manual SPC-1 Single Point Controller Operation Manual NOTICE: PPM Technology Limited shall not be liable for errors that may appear herein or for incidental or consequential damages in connection with or arising

More information

23 The Thermal Conductivity Detector

23 The Thermal Conductivity Detector 23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing

More information

TICO-EN. TiXML-Console TICO. User Manual V1.4.0.8

TICO-EN. TiXML-Console TICO. User Manual V1.4.0.8 TICO-EN TiXML-Console TICO User Manual V1.4.0.8 2008 Tixi.Com GmbH, Berlin Publication close: September 2008, v.1.4.0.8 This manual is protected by copyright. Any further sale is prohibited without the

More information

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

This document is intended to make you familiar with the ServersCheck Monitoring Appliance ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other

More information

Computer Lane Monitor for Windows

Computer Lane Monitor for Windows Computer Lane Monitor for Windows User Guide Supplement BRUNSWICK SERVICE PARTS & SUPPLIES MUSKEGON, MICHIGAN 1995, Brunswick Bowling and Billiards Corporation, 525 W. Laketon Avenue, P.O. Box 329, Muskegon,

More information

SCD Server. SCD Server Pro

SCD Server. SCD Server Pro SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c -

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c - Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c - User s Manual User s Manual Vigil Download Software Page 1 of 27 V2015.11 The Vigil is endorsed by: User s Manual Vigil Download

More information

Background Information

Background Information 1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software

More information

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature

More information

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone

More information

Chromatograph Maintenance and Troubleshooting Class # 5050

Chromatograph Maintenance and Troubleshooting Class # 5050 Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction

More information

User Manual V1.0. Remote Software

User Manual V1.0. Remote Software User Manual V1.0 Notice: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change

More information

HTO-1000 Thermal Oxidiser User Manual Version: 1.5 www.ecotech.com

HTO-1000 Thermal Oxidiser User Manual Version: 1.5 www.ecotech.com HTO-1000 Thermal Oxidiser User Manual Version: 1.5 www.ecotech.com HTO-1000 User Manual 1.5 This page is intentionally blank Page 2 Table of Contents Table of Contents... 3 List of Tables... 4 Manufacturer

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data

More information

PITE 3921 Battery Monitoring System User Manual P-140606-V1.0

PITE 3921 Battery Monitoring System User Manual P-140606-V1.0 User Manual P-140606-V1.0 4/F, Bldg A, Chiwan Industrial Park, Shaodi Rd., Chiwan, Shekou Area, Shenzhen, China TEL: +86-755-2680 5759 FAX: +86-755-2688 0310 www.pitetech.com 1 Catalog 1. INTRODUCTION...

More information

C n o t n e t n e t n s

C n o t n e t n e t n s Preface Thank you for choosing our product, for a better understanding of the product, we recommend you read the instruction and safety information before use. Notice: This user manual is an operation

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons

More information

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B MagIC 6100 Installation Manual Point of Sales Terminals TD06014B Contents Description 3 Introduction 3 Presentation of the MagIC 6100 terminal 3 Technical Data 4 Installation 5 Unpacking 5 Safety recommendations

More information

Quick Instructions for Setting up Swe-dish.

Quick Instructions for Setting up Swe-dish. Quick Instructions for Setting up Swe-dish. Physical Set-up. 1. Pick a location with a hard mainly level surface (feet on bottom of suitcase are adjustable if surface is uneven). 2. Align the Suitcase

More information

OxySense Gen III Operations Manual

OxySense Gen III Operations Manual OxySense Gen III Operations Manual OxySense GEN III 300 Series OxySense GEN III 5000 Series COMPLIES WITH ASTM 2714-08 OxySense, Inc. 13111 North Central Expressway, Suite 440 Dallas, Texas 75243 Phone

More information

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof

More information

ComTool Tool for managing parametric controllers

ComTool Tool for managing parametric controllers ComTool Tool for managing parametric controllers User manual 2 IMPORTANT WARNINGS BEFORE INSTALLING OR HANDLING THE DEVICE PLEASE CAREFULLY READ AND FOLLOW THE INSTRUCTIONS DESCRIBED IN THIS MANUAL. The

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer 450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry. IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The

More information

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200 Remote Access Gateway IGW/922 with DIL/NetPC ADNP/9200 First Steps SSV Embedded Systems Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ssv-embedded.de Document

More information

FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm

FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm 002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM

More information

STERILIZERS, LABORATORY DRYING OVENS

STERILIZERS, LABORATORY DRYING OVENS TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and

More information

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie

More information

Ultra-Portable Greenhouse Gas Analyzer User Manual

Ultra-Portable Greenhouse Gas Analyzer User Manual LOS GATOS RESEARCH Ultra-Portable Greenhouse Gas Analyzer User Manual Model 915-0011 Los Gatos Research 67 East Evelyn Avenue, Suite 3 Mountain View, CA 94041 Phone: 650-965-7772 Fax: 650-965-7074 www.lgrinc.com

More information

site monitoring Kit Site Monitoring Kit User Manual we prove it.

site monitoring Kit Site Monitoring Kit User Manual we prove it. site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of

More information

ibidi PumpControl Instruction Manual Version 1.5.2

ibidi PumpControl Instruction Manual Version 1.5.2 ibidi PumpControl Instruction Manual Version 1.5.2 ibidi PumpControl instructions II ibidi GmbH 2016, Version 1.5.2, 04 May 2016 Table of contents 1. General Information... 3 1.1 System Requirements...3

More information

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld device with Windows PC and suitable Software-applications

More information

Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...

Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display... Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5

More information

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

E&P HYDRAULICS Remote control EPRC-01 Level System Camper USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in

More information

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len. MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3

More information

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2 0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5

More information

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note. EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in

More information

Aeroqual Connect and Cloud

Aeroqual Connect and Cloud Aeroqual Connect and Cloud Page 1 Contents 1. Introduction to Aeroqual Connect and Cloud... 3 1.2. Aeroqual Connect... 3 1.3. Aeroqual Cloud... 3 2. How to Connect... 4 2.1. Aeroqual Connect... 4 2.1.1.

More information

Instruction Manual FL

Instruction Manual FL 3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front

More information

User manual DC Safelog. Edition 2014-01-20

User manual DC Safelog. Edition 2014-01-20 User manual DC Safelog Edition 2014-01-20 2 User manual DC Safelog 1. TABLE OF CONTENTS 2 1. Table of contents... 2 2. Presentation of the parts in DC Safelog... 3 3. Before using the alarm for the first

More information

SB9011D All-in-one Touch POS Terminal USER MANUAL

SB9011D All-in-one Touch POS Terminal USER MANUAL SB9011D All-in-one Touch POS Terminal USER MANUAL Table of Contents 1 Overview... 2 1.1 Safety Information... 2 1.2 Electromagnetic compatibility statement... 3 2 Installation Guide... 4 2.1 Appearances...

More information

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720 User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version

More information

Interface Level And Point Level Analyzers & Sensors

Interface Level And Point Level Analyzers & Sensors Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible

More information

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

1 Global Warranty Service Agent Guide. Service Agent Help Guide. Service Agent Starts the Claim

1 Global Warranty Service Agent Guide. Service Agent Help Guide. Service Agent Starts the Claim 1 Global Warranty Service Agent Guide Service Agent Help Guide Service Agent Starts the Claim 1 2 Global Warranty Service Agent Guide Table of Contents Warranty Guidelines... 3 Entering a Claim... 4 Log

More information

BTMPico Data Management Software

BTMPico Data Management Software BTMPico Data Management Software User Manual Version: 1.3 for S/W version 1.16F or higher 2013-04-26 Page 1 of 22 Table of Contents 1 Introduction 3 2 Summary 5 3 Installation 7 4 Program settings 8 5

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

PTPhoneManager II. User guide

PTPhoneManager II. User guide COMMUNICATION AT ITS BEST PTPhoneManager II User guide Communications A member of PEIKER group DOCUMENT PEI TEL Communications GmbH - PTPhoneManager II - 2 - T ABLE OF CONTENTS Table of contents Table

More information

LED Cube Direct Control 30 ORDERCODE 41131

LED Cube Direct Control 30 ORDERCODE 41131 LED Cube Direct Control 30 ORDERCODE 41131 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Cube Direct Control 30 brings excitement to any venue. Whether you

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

Watchdog Monitor user guide

Watchdog Monitor user guide General The Watchdog AW-4, in short AW-4, can be controlled and monitored by a centralized monitor server. This server is located in a large Dutch server centre with high speed connections, directly connected

More information

DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW...5 1.1 MINIMUM PC REQUIREMENTS...5 2. INSTALLING THE PROGRAM...

DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW...5 1.1 MINIMUM PC REQUIREMENTS...5 2. INSTALLING THE PROGRAM... DVR4x4RemoteViewer.book Page 3 Tuesday, February 15, 2005 9:19 AM DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW...5 1.1 MINIMUM PC REQUIREMENTS...5 2. INSTALLING THE PROGRAM...5

More information

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace

More information

ROM ACCESS CONTROL USER S MANUAL

ROM ACCESS CONTROL USER S MANUAL ROM ACCESS CONTROL USER S MANUAL Manual Software Pro-Access Page: 1 PRO-ACCESS SOFTWARE GUIDE PRO-ACCESS SOFTWARE GUIDE 1 0. INTRODUCTION 3 1. INSTALLIG THE SOFTWARE 4 2. SOFTWARE OPERATORS AND COMPETENCIES.

More information

for CS flow / dew point sensors

for CS flow / dew point sensors Operating Manual Service Software for CS flow / dew point sensors FA300/ VA300/ DP300/ FA4XX / VA4XX - 1 - V-3-03-2008 Service Software for flow / dew point sensors Introduction This service software can

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

Sentry Bulldog Shutdown Management Software (For UNIX Series)

Sentry Bulldog Shutdown Management Software (For UNIX Series) Sentry Bulldog Shutdown Management Software (For UNIX Series) User Manual Table of Contents Introduction...4 Sentry Bulldog Installation...5 Sentry Bulldog Services...6 Sentry Bulldog Monitor...7 Networking...8

More information

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

CNC-STEP. LaserProbe4500 3D laser scanning system Instruction manual LaserProbe4500 CNC-STEP "LaserProbe4500" 3D laser scanning system Instruction manual 2 Hylewicz CNC-Technik Siemensstrasse 13-15 D-47608 Geldern Fon.: +49 (0) 2831 133236 E-Mail: info@cnc-step.com Website:

More information

Fractional Distillation and Gas Chromatography

Fractional Distillation and Gas Chromatography Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7 KCU-02 Monitor Software Installation User Manual For Windows XP and Windows 7 Headquarters : No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775

More information

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual v1.0 August 23, 2007 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 9 ICON KEY 1 THE TAURUS RAID 1 AVAILABLE

More information

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Billion BiPAC 7800NL Wireless-N ADSL2+ Firewall Router PLEASE READ THE QUICK START GUIDE

More information

32 Transferring Projects and Data

32 Transferring Projects and Data 32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1

More information

Reference Manual. IQ System Database Manager Software

Reference Manual. IQ System Database Manager Software Reference Manual IQ System Database Manager Software Honeywell Analytics, Inc. 405 Barclay Blvd Lincolnshire, IL 60069 (800) 711-6776 (847) 955-8200 Fax (800) 995-4992 P/N 13-241 Version 6 27AUG2012 Note:

More information

GE Security. FHSD Monitor / Web Server user manual

GE Security. FHSD Monitor / Web Server user manual GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the

More information

Promethean Trouble Shooting Tips v 2.0. A quick guide for the most common problems

Promethean Trouble Shooting Tips v 2.0. A quick guide for the most common problems Promethean Trouble Shooting Tips v 2.0 A quick guide for the most common problems [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc. Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started

More information

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout

More information

User's Guide DylosLogger Software Version 1.6

User's Guide DylosLogger Software Version 1.6 User's Guide DylosLogger Software Version 1.6 The DylosLogger software allows users of Dylos Air Quality Monitors equipped with PC interface to easily record, download, and graph data. The COM port is

More information

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03 smart-house Web-Server Manual Version 1.03 CARLO GAVAZZI HANDEL A/S, Over Hadstenvej 42, DK-8370 Hadsten, Danmark Tlf. 89 60 61 00, Fax 86 98 15 30, Reg.nr. 65 206 Internet: http://www.carlogavazzi.com/ac/dk

More information