Georgia State University. Urban Life Building Roof Replacement
|
|
- Bertina Barton
- 8 years ago
- Views:
Transcription
1 ENGINEERING AND ENVIRONMENTAL 140 DECATUR STREET SE, ATLANTA, GA GEORGIA STATE UNIVERSITY - FACILITIES DESIGN & CONSTRUCTION 34 BROAD STREET, SUITE 100 ATLANTA, GA DRAWING INDEX A-0 PROJECT INFORMATION A-1 UPPER ROOF PLAN - 12-STORY TOWER A-2 LOWER ROOF PLAN - 5-STORY ROOF ROOF DETAILS ROOF DETAILS ROOF DETAILS PROJECT SITE GENERAL NOTES APPLICABLE CODES INTERNATIONAL BUILDING CODE WITH 2014, 2015 GEORGIA AMENDMENTS INTERNATIONAL PLUMBING CODE WITH 2014, 2015 GEORGIA AMENDMENTS APPROXIMATE ROOF AREAS APPROXIMATE 12-STORY TOWER ROOF AREA: PROJECT SITE: 140 DECATUR STREET, SE ATLANTA, GA EDITION 2012 EDITION 17,700 SQ.FT. SCOPE OF WORK ACTUAL DRAWING SIZE IS 24" X36" MAIN ROOFS: ROOF REPLACEMENT AND ROOF RELATED RENOVATIONS OF THE EXISTING FACILITY KNOWN AS THE URBAN LIFE BUILDING LOCATED AT 140 DECATUR STREET IN ATLANTA, GEORGIA. THE PROJECT REQUIREMENTS INCLUDE THE 12-STORY TOWER W/ PENTHOUSE AND THE ADJOINING 5-STORY STRUCTURE. WORK ON THE 12-STORY AND THE 5-STORY MAIN ROOFS INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. DEMOLITION OF THE EXISTING TAPERED ROOF MEMBRANE, INSULATIONS, DETERIORATED UNDERLAYMENTS, FLASHINGS AND SHEET METAL TRIM WHERE SPECIFIED. EXISTING VAPOR BARRIER TO REMAIN. CONTRACTOR IS TO SALVAGE REUSABLE MATERIALS AS REQUIRED BY THE SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR IS TO USE CARE TO AVOID DAMAGE TO THE EXISTING LIGHTNING PROTECTION SYSTEM. 2. COVER THE EXISTING PREPARED VAPOR BARRIER WITH A NEW SECONDARY SBS TORCH GRADE MODIFIED MEMBRANE THAT IS FULLY BONDED TO THE ROOF SURFACE. INSTALLATION OF SECONDARY FLASHINGS IS REQUIRED, THE FLASHING ARE TO BE 2-INCHES HIGHER THAN THE PROJECTED HEIGHT OF THE NEW LIGHTWEIGHT FILL. 3. INSTALLATION OF A NEW 1/4-INCH TAPERED LIGHTWEIGHT CONCRETE WITH ENCAPSULATED POLYSTYRENE FILLER BOARDS. THE FINISHED R-VALUE SYSTEM IS TO HAVE AN AVERAGE OF R INSTALL A NEW VENTED BASE SHEET THAT IS MECHANICALLY ATTACHED TO THE LIGHTWEIGHT FILL. THE FASTENING PATTERN SHALL MEET ASCE 7 REQUIREMENTS FOR BUILDINGS OF THIS HEIGHT AND EXPOSURE. INCREASE FASTENER DENSITIES AT CORNERS AND PERIMETERS. 5. INSTALL A NEW COVER BOARD IN AN APPROVED ADHESIVE. THE ADHESIVE IS TO BE AS APPROVED BY ROOF SYSTEM MANUFACTURER AND MEET WIND UP-LIFT REQUIREMENTS. 6. INSTALL A NEW 80 MIL PVC ROOF MEMBRANE THAT IS FULLY ADHERED TO THE COVER BOARD. A 30-YEAR ROOF MANUFACTURER'S GUARANTEE AND A 3-YEAR CONTRACTOR'S WARRANTY IS REQUIRED. 7. INSTALL MANUFACTURER APPROVED FLASHING MATERIALS AS SHOWN IN DESIGN DOCUMENTS. 8. INSTALL EXISTING SHEET METAL TRIMS AND FLASHINGS AS DESCRIBED IN THE BID DOCUMENTS. PROTECT AND REUSE THOSE COMPONENTS SHOWN TO BE REUSED. DAMAGE TO COMPONENTS, BECAUSE OF NEGLIGENCE OF THE CONTRACTOR, ARE TO BE REPLACED AT NO COST TO THE OWNER. 9. INSTALL HEAVY DUTY WALKPADS FROM ROOF TOP DOOR TO OBSERVATION DECK. PLACE ADDITIONAL WALKPADS AT DOORWAYS, LADDERS, AND AROUND SERVICEABLE EQUIPMENT. 10. DEMOLISH THE EXISTING WOOD PLANK ING FROM ROOF TOP OBSERVATION DECK AND DISPOSE. INSTALL NEW COMPOSITE WOOD PLANK DECK THAT IS SCREW FASTENED TO THE EXISTING STRUCTURE. 12. INSPECT AND REFURBISH THE EXISTING LIGHTNING PROTECTION SYSTEM. INCLUDE IN BID COST TO REPLACE BROKEN OR MISSING COMPONENTS. A LETTER OF FINDINGS IS TO BE SUBMITTED TO THE OWNER AT THE COMPLETION OF THE PROJECT. WORK ON THE PENTHOUSE ROOF INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: 1. DEMOLITION OF THE EXISTING ROOF MEMBRANE, INSULATIONS, DETERIORATED UNDERLAYMENTS, SHEET METAL TRIM WHERE SPECIFIED. CONTRACTOR IS TO SALVAGE REUSABLE MATERIALS AS REQUIRED BY THE SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR IS TO USE CARE TO AVOID DAMAGE TO THE EXISTING LIGHTNING PROTECTION SYSTEM. VERIFY SUFFICIENT SLOPE IN THE STRUCTURAL DECK. 2. INSTALL A LAYER OF 2.5-INCH THICK POLYISOCYANURATE INSULATION SET IN COLD ADHESIVE. SELECT ADHESIVE AND PATTERN MEET OR EXCEED EXISTING WIND REQUIREMENTS. 3. INSTALL A NEW COVER BOARD IN AN APPROVED ADHESIVE. THE ADHESIVE IS TO BE AS APPROVED BY ROOF SYSTEM MANUFACTURER AND MEET WIND UP-LIFT REQUIREMENTS. 4. INSTALL A NEW 80 MIL PVC ROOF MEMBRANE THAT IS FULLY ADHERED TO THE COVER BOARD. A 30-YEAR ROOF MANUFACTURER'S GUARANTEE AND A 3-YEAR CONTRACTOR'S WARRANTY IS REQUIRED. 5. INSTALL MANUFACTURER APPROVED FLASHING MATERIALS AS SHOWN IN DESIGN DOCUMENTS. 6. INSTALL EXISTING SHEET METAL TRIMS AND FLASHINGS AS DESCRIBED IN THE BID DOCUMENTS. PROTECT AND REUSE THOSE COMPONENTS SHOWN TO BE REUSED. DAMAGE TO COMPONENTS, BECAUSE OF NEGLIGENCE OF THE CONTRACTOR, ARE TO BE REPLACED AT NO COST TO THE OWNER. GENERAL NOTES DRAWINGS ARE FOR BID PURPOSE ONLY 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGN PROFESSIONAL VIA RFI OF ANY ERRORS, OMISSIONS, INCONSISTENCIES, DISCREPANCIES, AND CONFLICTS WITHIN THE DRAWINGS AND SPECIFICATIONS AND FIELD CONDITIONS NO LESS THAN 72 HOURS BEFORE THE BID IS DUE. 2. CONTRACTOR IS TO VERIFY ALL DIMENSIONS, CONDITIONS, AND QUANTITIES IN FIELD. QUANTITIES SHOWN ARE FOR ESTIMATING PURPOSES ONLY. 3. CONTRACTOR AND SUBCONTRACTORS SHALL BE REQUIRED TO VISIT THE PREMISES TO INSPECT EXISTING CONDITIONS, BECOME FAMILIAR WITH LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND CORRELATE OBSERVATIONS WITH REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. 4. CONTRACTOR SHALL COORDINATE REQUIREMENTS AND PROVIDE PROOF OF INSURANCE PRIOR TO THE START OF WORK. 5. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, LICENSES AND GOVERNMENT FEES AS REQUIRED. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT THE BUILDING OCCUPANTS, MATERIALS, EXISTING PROPERTY, AND FINISHES. EXISTING-TO-REMAIN CONSTRUCTION, MATERIALS, OR EQUIPMENT DAMAGED BY THE CONTRACTOR SHALL BE RESTORED TO ORIGINAL CONDITION. AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL DOCUMENT EXISTING CONDITIONS PRIOR TO THE START OF WORK AND SUBMIT RECORDS TO OWNER'S REPRESENTATIVE. THE CONTRACTOR IS TO NOTIFY THE DESIGN PROFESSIONAL OF ANY DAMAGE TO THE BUILDING STRUCTURE OR FACADE ELEMENTS DISCOVERED DURING REPAIR PROCEDURES. 7. CONTRACTOR SHALL VERIFY EXISTING PLUMBING AND ELECTRICAL LINES AND EQUIPMENT THAT WILL BE ACCESSED AS PART OF WORK PERFORMED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, LABOR, MATERIALS, AND COMPONENTS REQUIRED FOR THE TEMPORARY RELOCATIONS OF MECHANICAL/ELECRICAL EQUIPMENT AND PLUMBING LINES DURING THE REPAIR WORK. 8. THE CONTRACTOR SHALL PROVIDE SHORING, BRACING, AND SUPPORT AS REQUIRED TO MAINTAIN THE STRUCTURAL INTEGRITY OF THE EXISTING CONDITIONS DURING THE WORK. DO NOT STOCKPILE CONSTRUCTION MATERIAL IN A MANNER THAT WILL OVERLOAD OR EXCEED THE CAPACITY OF THE STRUCTURAL MEMBERS 9. THE CONTRACTOR MUST SUBMIT DEMOLITION AND CONSTRUCTION SCHEDULES TO THE OWNER AND DESIGN PROFESSIONAL FOR APPROVAL PRIOR TO BEGINNING DEMOLITION. 10. CONTRACTOR SHALL COORDINATE USE OF PREMISES UNDER THE DIRECTION OF THE OWNER. TEMPORARY DISRUPTIONS TO THE USE OF THE EXISTING BUILDING, INCLUDING NOISE, DUST AND DISRUPTION OF UTILITIES, SHALL BE COORDINATED A MINIMUM OF 48 HOURS IN ADVANCE AND APPROVED BY THE OWNER. CONTRACTOR WORK NOT COORDINATED IN ADVANCE WHICH CAUSES DISRUPTIONS TO THE USE OF THE BUILDING MAY BE STOPPED BY THE OWNER AND SHALL NOT BE COMMENCED AGAIN UNTIL PROPER COORDINATION IS ACHIEVED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM WORK STOPPAGES OR DELAYS CAUSED BY CONTRACTORS LACK OF COORDINATION WITH OWNER. 11. THE CONTRACTOR SHALL MAINTAIN PREMISES FREE FROM ACCUMULATION OF WASTE MATERIAL AND RUBBISH. CONSTRUCTION DEBRIS SHALL BE REMOVED IN A TIMELY MANNER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE WATER TIGHTNESS OF THE AREAS OF WORK. PROVIDE TEMPORARY PROTECTION OF THE EXISTING CONSTRUCTION FROM THE WEATHER UNTIL REMOVED PORTIONS ARE COMPLETELY REPLACED WITH NEW CONSTRUCTION. TEMPORARY WEATHER PROTECTION SHALL BE WATERTIGHT. 13. IN THE EVENT OF CONFLICT BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, CONTACT DESIGN PROFESSIONAL FOR CLARIFICATION. THE MORE STRINGENT REQUIREMENT SHALL GOVERN UNLESS WRITTEN NOTIFICATION IS PROVIDED BY THE DESIGN PROFESSIONAL. 14. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL JOB SAFETY DURING THE REPAIR WORK. 15. ALL DIMENSIONS AND PENETRATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR IS TO FIELD VERIFY ALL DIMENSIONS AND OTHER CONDITIONS THAT MAY AFFECT BIDS. APPROXIMATE 5-STORY ROOF AREA: APPROXIMATE PENTHOUSE ROOF AREA: 8,000 SQ.FT. 1,140 SQ.FT. BID ALTERNATES: BID ALTERNATE 1 1. The SCOPE IS REDUCED BY REMOVING THE 5-STORY STRUCTURE FROM THE SCOPE OF WORK. BID ALTERNATE 2: 16. DRAWINGS ARE INTENDED TO BE PRINTED AT 24X36.. A-0
2 B 1, A-1
3 2, , A-2
4 Urban Life Building Roof Replcement
5 GSU Urban Life Building
6 GSU Urban Life Building
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
More informationLarry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:
More informationSINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
More informationAPPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More information1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
More informationCITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES
CITY OF BELL 6330 PINE AVENUE BELL, CA 90201 PH: (323) 588-6211 FAX: (323) 771-9473 CITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES I. INTRODUCTION City of Bell
More informationSTANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
More informationLow-slope reroofing guidelines
Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August
More informationSECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING
SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationFireSmart IRS Insulating Roof Screed
Insulating Roof Screed CI/SfB January 2004 CI/SfB January 2004 M2 P M2 P Icopal Ltd Barton Dock Road Stretford, Manchester M32 0YL Telephone: 0161 865 4444 Fax: 0161 866 9859 Technical Fax: 0161 865 8433
More informationITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
More informationSeptember 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
More informationCommercial Roof Management
Disclaimer: This material is designed and intended for general informational purposes only, and is not intended, nor shall it be construed or relied upon, as specific legal advice. Roof damage is a leading
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationBuilding Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
More informationHartsfield-Jackson Atlanta International Airport s
Hartsfield-Jackson Atlanta International Airport s 2008-09 Closed Projects (Posted 1/6/2009) FC-3007000038C: MISCELLANEOUS BUILT-UP ROOF AND SINGLE PLY ROOF REPAIRS AT H-JAIA Furnish all labor, equipment,
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationREQUEST FOR PROPOSALS
Page 1 of 6 REQUEST FOR PROPOSALS Issue Date: 2/19/2013 RFP# WHS-2013-001 Title: Services for roofing improvements and annual roof assessments, Windsor School Complex, State Street, Windsor, Vermont Issuer
More informationINSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.
More informationDISTRICT OF BARRIERE REQUEST FOR PROPOSAL
DISTRICT OF BARRIERE REQUEST FOR PROPOSAL SUPPLY AND INSTALLATION OF FLAT ROOF SYSTEM AND RELATED REPAIRS RFP No. 2014-02 1. SUMMARY OF REQUIREMENT The District is planning on reroofing the existing flat
More informationSECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.
SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More informationRACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012
RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012 Commercial rooftops represent the most available, sustainable and secure real estate for new
More informationTARRANT COUNTY DETAIL STANDARDS
TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout
More informationCHICAGO ROOFING CONTRACTORS ASSOCIATION
CHICAGO ROOFING CONTRACTORS ASSOCIATION JANUARY 22, 2016 Roofing Claims & Lawsuits Stephen M. Phillips Hendrick, Phillips, Salzman & Flatt, P.C. 230 Peachtree Street, Suite 2500 Atlanta, GA 30303 (404)
More informationSECTION 07 54 23 PVC SINGLE PLY ROOFING
SECTION 07 54 23 PVC SINGLE PLY ROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Attached GENERAL CONDITIONS, GENERAL NOTES, INSTRUCTIONS TO BIDDERS, AND BID FORM are components of this section. B. Section
More informationThe existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
More informationSECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
More informationSECTION 02100 SITE PREPARATION
SECTION 02100 SITE PREPARATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General Conditions and Supplementary Conditions and Division 1 through Division
More informationAPPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT
APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT City of Swartz Creek 8083 Civic Drive Swartz Creek, MI 48473 810-635-4464 Fee Received: $ Date: / / Receipt No: Demolition Permit (including Right of
More informationTHERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS
OPTIONAL TITLE 24 CRITICAL POINTS POLYISO THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE DESCRIPTION TORCH OVER POLYISO (5,7,9 YR) TH/BS-TH/CS 2 No 0. SUBSTRATE. THERMOTEK USA PRO 2.0 FV
More information7. Do you perform any out of state work?... If yes, in what states and provide details of work performed
Applicant s Name* (*If more than one entity, attach separate sheet with description of each entity s operations, relationship to each other and ownership.) Contractors Application Agent Applicant Mailing
More informationBasement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
More informationA. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
More informationELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1
KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1
More informationFLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS
FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS Table of Contents Chapter 1: FLAT ROOF REPAIR - CUT COST WITHOUT CUTTING CORNERS Chapter 2: PVC RECOVER SYSTEM HOW IT WORKS Chapter 3: 8 STRATEGIES TO
More information!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
More informationAPPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE Table Application Type Description Page 1A-1 Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1A-2
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationCITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL 33034 305-247-8222 ROOFING PERMIT APPLICATION
IF SUBSIDIARY, PROVIDE MASTER PERMIT NUMBER HERE: CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL 33034 305-247-8222 ROOFING PERMIT APPLICATION Location of Improvements
More informationROOF CONSTRUCTION SCIENCE (METCT092)
ROOF CONSTRUCTION SCIENCE (METCT092) This training program is intended for applicators that are interested in gaining an understanding of the various technologies incorporated in roof systems, including
More informationRoof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00.
Report Fairbank Complex 40 Fairbank Road RBA Project No. 2014007.00 Prepared by: 33 Center Street, 2 nd Floor Burlington, MA Tel: 781-273-1537 Fax: 781-273-1695 TABLE OF CONTENTS Roof Repair Project Report...
More informationThe Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois
Wiss, Janney, Elstner Associates, Inc. 10 South LaSalle Street, Suite 2600 Chicago, Illinois 60603 312.372.0555 tel 312.372.0873 fax www.wje.com The Building Group First Tuesdays October 2, 2012 Jason
More information0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
More informationADDENDUM #2 November 4, 2015 IFB-15-881
ADDENDUM #2 November 4, 2015 IFB-15-881 Roof Replacement Housing Authority of Kansas City 920 Main Street, Suite 701 Kansas City, MO 64105 NOTICE TO ALL POTENTIAL RESPONDENTS The following addendum to
More informationCrescent Valley High School Roof Investigation
Crescent Valley High School Roof Investigation Project: Corvallis School District Crescent Valley High School Roof Date: July 26, 2011 Report By: Rowell Brokaw Architects: Mark Young, AIA, Chris Andrejko
More informationA. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's "The NRCA Roofing and Waterproofing Manual" apply to work of this Section.
SECTION 075419 POLYVINYL CHLORIDE (PVC) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationEstimated Cost of Repair
1 Applicant: Property: Home: Business: Assessor: Applicant Number: Type of Loss: Hurricane Date Contacted: 1/18/2014 Date of Loss: 10/29/2012 Date Received: 1/14/2014 Date Inspected: 2/4/2014 Date Entered:
More informationCHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS
TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes
More informationAvoiding the Landfill: The Recycling of Vinyl Roof Membranes
Avoiding the Landfill: The Recycling of Vinyl Roof Membranes With its European counterparts blazing the trail, the North American vinyl (PVC) roofing industry has entered a new phase in its commitment
More informationCONTRACTORS LIABILITY QUESTIONNAIRE
CONTRACTORS LIABILITY QUESTIONNAIRE Please answer all questions fully. Submit this Questionnaire with a completed ACORD Commercial Insurance Applicant Information Section and prior carrier loss runs. Named
More informationRESIDENTIAL ROOF PERMITTING - 101. A REFRESHER WORKSHOP September 11, 2014
RESIDENTIAL ROOF PERMITTING - 101 A REFRESHER WORKSHOP September 11, 2014 Agenda Basics of Permit Application Use of Charlotte County GIS system Florida Product Approvals Top Application Mistakes Standard
More informationAir-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
More informationReplacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
More informationCity of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR
Scott A. Smith Finance Director sasmith@somersworth.com (603) 692-9504 One Government Way Somersworth, New Hampshire 03878 (603) 692-4262 www.somersworth.com City of Somersworth, New Hampshire OFFICE OF
More informationNRLRC Annual Seminar
NRLRC Annual Seminar What Are the Greatest Risks of Major Liability Exposures for Roofing Contractors? Austin, Texas September 11, 2014 Stephen M. Phillips, Esq. Hendrick, Phillips, Salzman & Flatt, P.C.
More information07 5423-1 THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center
PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 5423 THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center A. Tear off existing roof system down to wood deck and install new Thermoplastic membrane roofing
More informationAsbestos Abatement Work Plan for the Carter Carburetor Superfund Site
for the Prepared for: ACF Industries LLC 101 Clark Street St. Charles, Missouri 63301 Prepared by: AMEC Environment & Infrastructure, Inc. 15933 Clayton Road, Suite 215 Ballwin, Missouri 63011 Project
More informationRoof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building
Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building Prepared For: Ms Marilyn Bittenbender Colliers International 805 New Hampshire St Lawrence Kansas, 66046 Prepared
More informationINSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
More informationSECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
More informationRecord of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER
Department of Advanced Education and Skills Apprenticeship and Trades Certification Division Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER Note to Apprenticeship Applicants
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationWarranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2
Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2 PROTECTING YOUR DURO-LAST ROOFING 3 Safety Measures 3 Inspection 3 Maintenance Program 4 Sealants 4 Drainage 4 Parapets Walls 4 Building
More informationC. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.
SCOPE OF WORK Project Title: Replace Deteriorated Roof Singles at Cape Lookout National Seashore Maintenance Shop PMIS # 159350 Prepared By: Mike Baker Cape Lookout National Seashore 131Charles St Harkers
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationCITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
More informationCSC-DIVISION 1-MASTER SECTIONS Description
CSC-DIVISION 1-MASTER SECTIONS Description 01 11 00 Summary of Work by Consultant 01 12 00 Multiple Contract Summary by Consultant 01 14 00 Work Restrictions see below 01 21 00 Allowances by Consultant
More information+1.877.497.3528 info@grscanadainc.com www.grscanadainc.com
WORK ORDER AGREEMENT I. Work Site Documentation Quotation / Bid # Core Samples / Infrared Purchase Order # Consultant Report Start Date: II. Work Site Address Building Name Street City Province Postal
More informationChapter 11: Demolition
City of Independence Chapter 11: Demolition In this chapter you will find: Demolition Mothballing Treatment Types of Demolition By Neglect and Recommended Corrective Measures DEMOLITION Photograph on cover
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationGet Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money
Get Rid of Roof Problems for Good How spray foam roofing can protect your building and make you money What is a Spray Foam Roofing System? 300 MILLION Board feet of roofing spray foam installed annually
More informationASBESTOS MANAGEMENT PROGRAM
ASBESTOS MANAGEMENT PROGRAM Prepared By: Triumvirate Environmental Program Approval Developed: August 2011 Updated: June 2015 Associate Vice President of Public Safety & Administrative Services Date Associate
More informationG VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered
More informationSECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
More informationAnalysis II Façade Redesign: Architectural Precast Panels
Analysis II Façade Redesign: Architectural Precast Panels Analysis II Façade Redesign: Architectural Precast Panels Overview: This analysis covers the comparison of the current EIFS façade and my proposed
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationHow To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
More informationRoof Inspection. Summary Report
Phone: (561) 866 9956 www.real-estate-inspections.com Roof Inspection Summary Report Subject Property File Number: 05-15-RF-002 Inspector: Craig Milliken, PE CPM Real Estate Inspections, Inc. Date of Inspection:
More informationPreventing Ice Dams on Roofs
Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the
More informationROOF REPLACEMENT SPECIFICATIONS
ROOF REPLACEMENT SPECIFICATIONS Prepared For: PLYMOUTH TOWNSHIP DPW 46555 PORT STREET PLYMOUTH, MICHIGAN Owner: Charter Township of Plymouth 9955 North Haggerty Road Plymouth, Michigan 48170 Roofing Consultant:
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationC3 Membrane Roofing System (C3 Illusions, C3 Evolution, C3, C3 Plus, and C3 Fleece Back) I. Cooley, mc. 50 Esten Avenue Pawtucket, RI 02860
1. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT Housing. Federal Housing Commissioner Series and Series Number: MATERIALS RELEASE NO: 1321 TO: DIRECTORS, SINGLE FAMIL!I HOCs DIRECTORS, MUL TIF AMIL vi HUBs
More informationIf you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
More information2011 Dodson Publications, Inc. Page 1 of 6 September 16, 2011 8:19 AM
Contractor Makes Quick Work of Colossal Recover Maintenance Contract Helps Land Contractor Huge Reroofing Job in Colorado by Andrew Romano, senior product manager, GAF It s the closest most crews get to
More informationBituminous Sheet Flat Roofs: Their repair and maintenance
Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and
More informationRoofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
More informationDIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
More informationWater Damage During Construction
Allianz Global Corporate & Specialty Americas Water Damage During Construction May 2012 A Contractor s Loss Prevention Guide Water damage losses are a major cause of loss during construction and represent
More informationWESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
More informationScope of works. Name Job# TBA -1. Project: Bathroom Renovation
Scope of works Name Job# TBA -1 Address Date Suburb P. code Phone H BH 0 Mobile E-mail Project: Bathroom Renovation.01 Demolition Strip out and remove from site: All existing fixtures, fittings and cabinets
More informationSolicitation DTFACN-11-R-00079 Attachment #9
These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation
More informationTABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
More informationROOFING CONTRACTORS QUESTIONNAIRE
ROOFING CONTRACTORS QUESTIONNAIRE ALL QUESTIONS MUST BE ANSWERED 1. Applicant Name: Website Address: Address: Years in business under the applicant name: Are you an NRCA (National Roofing Contractors Association)
More information