Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters
|
|
- Elizabeth Morrison
- 8 years ago
- Views:
Transcription
1 Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters A specifically designed programme for Da Afghanistan Breshna Sherkat (DABS) Afghanistan 11/10/2010 1
2 Technologies have evolved over a period of time and so have the meters 11/10/2010 2
3 Conventional meters Meters conventionally measured a single quantity kwh kvarh kvah Meters were used for commercial purpose, (record consumption and bill to consumer) 11/10/2010 3
4 MDI PSEB 28 11/10/2010 th January This was the meter in good old days
5 The modern meter has evolved over time Today s meter is different from yesterday s meter What is the difference? 11/10/2010 5
6 Today s meters are data loggers they churn out a lot of data They give much more than energy readings 11/10/2010 6
7 Each meter can log a lot of data Data is useful, only if it is purpose oriented 11/10/2010 7
8 Yesterday Single parameter (kwh) Single reading Manual reading Error prone Manual computation Error prone again! Multiple parameters Multiple readings (load survey) Electronic reading Less error prone Computers aid computations Less errors Today 11/10/2010 8
9 Advantages of electronic meters More accurate than electromechanical meters They are data loggers & log time stamped data They are read electronically & human errors eliminated Remote reading is possible (LPR, PSTN, GSM, GPRS) They can detect & log illogical events (tampers) Appropriate for consumer end meters only 11/10/2010 9
10 Yesterday, with electro mechanical meters Manual reading Consumption determined locally Today, with modern electronic meters Read electronically, not from display Complicated tariffs Consumption determined from computer, far away from meter Software (BCS) needed for data extraction This only extracts data from the meter 11/10/
11 Metering system software meter has a large amount of data, not practical to read using Software supplied by display, better to read meter manufacturers is Electronically not sufficient for Third party application deriving information software or services are from the data now needed We will deal with Meter Reading and system software for meter reading/ data extraction. 11/10/
12 Engineering plastic enclosure, better aesthetics LCD display with Backlight Over view of Electronic meter Calibration LED Inductively coupled PPU Rating plate Button for reverse scrolling Optical Port for electronic reading Front side sealing arrangement Button for display scrolling / scroll lock Extended terminal Block (Transparent) Terminal Block 11/10/
13 Information available in modern electronic meters 11/10/
14 Display & logged parameters Information in electronic meters can be classified as Display mode Auto display (for quick reference) Push button display (for detailed information) Scrolls automatically Displays Can be parameters accessed by for meter reader consumer viewing To see Can history be viewed data & tamper from information window when meter is Useful sealed to identify meters that need closer investigation Information is of consumer interest 11/10/
15 Display Parameters Information shown on the display of electronic meter TOU definition Self diagnostics LED Segment check Battery & NVM health RTC date & time Basic information Meter serial no. Instantaneous parameters V, I, PF, kw, kvar etc. Power On/Off hours Rising demand with elapsed time Billing information TOU wise MDs 6 or 12 history data Tamper information Missing potential Current reverse Short/Open circuit Load imbalance Date/time in RTC Cumulative Registers Cum count of events 11/10/
16 Logged Parameters 11/10/
17 Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions These are electrical parameters as seen by meter at the time of reading or can be read locally using MRI Can cover Voltage, Current, PF, kw, kvar, kva etc. They are interpreted & displayed in the BCS 11/10/
18 Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions These are based on tariff type programmed to meter These are packets of information on billing parameters like energy, MD etc. for each billing cycle They are also interpreted & displayed in the BCS 11/10/
19 Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions Logged Parameters They are periodic interval-wise information, intervals known as SIP SIP is typically ½ hour for consumer meters & ¼ hour for boundary meters Generally average values of kwh, kvarh, kvah, frequency, PF, Voltages, Currents, Power Down Time etc. 11/10/
20 Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions They are never a conclusive proof that a No consumer meter can has be tampered called tamper proof meter These are simply illogical electrical events as seen by meter The correct way is to refer to them as events and not tampers Modern meters have 3 types of tamper related features Tamper proof features Tamper deterrent features 11/10/ Tamper evident features
21 Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions They are interchange of information between meter & MRI They include change of tariff programme in meter, definition of kvarh & kvah, resetting MD, changing date/time etc. 11/10/
22 Meter Reading Instrument (MRI) 11/10/2010 PREPARED BY: Kailash Jain 22
23 What Is MRI? Hand Held Unit (HHU) for Meter Reading. Small, compact DOS or Windows Computer, PDA Capable to communicate with : Static Energy Meters /computer 11/10/
24 Uses of MRI Data collection from Meter Can read different make meters with Common MRI (CMRI) Instantaneous Parameters checked by installcheck S/w 11/10/
25 Features Of MRI Battery operated Instrument. Comprises of : A Keypad. LCD Display. Communication Ports. Charger Connector. Pre loaded Software. 11/10/
26 Analogic MRI LCD Screen Power/Resume Switch & Status LEDs 45 Key Membrane Keypad 4-6 MB for data storage 2 MB for program storage 16 line display ( 16 *24 ) 100% PC Compatibility in a Rugged Hand Held Runs MS-DOS and Virtually any PC Program PC Communications Software at up to 115K bps Optional second RJ-11 Port through built-in 11/10/
27 Communication Ports, Optical Cord & Charger RS 232 Port RJ-11 Port Charger Pin Battery Charger Common Optical cord 11/10/
28 MRI - Battery Environment friendly battery Line or battery powered Quick charging Light weight charger One can use the MRI even when charger is connected Battery self discharge rate is low. With survey reads 200 meters data & without survey reads 400 meters data for 8 MB. (Depends on memory size) 11/10/
29 MRI - Software Before meter reading battery healthy condition can be checked. Allows local reading of Electrical parameters and display of vector diagram Displays Energy values, used for meter testing on site. MRI is a computer, programmed as dumb terminal or DATA TRANSPORTER. 11/10/
30 Menu Visible on MRI Screen 1 SEMS 2 SEMS-CHK 3 L&T 4 PHASOR 5 DUKE 6 BATLEVEL Pressing Option-1 for Secure Meter 0. Quit 1.Read Meter Data 2.Dump Data 3.Read Energy 4.Calibration 5.Terminal 6.Space 7.Identification No 8.Load survey Days 11/10/
31 Electronic Meter Reading Methods Direct Reading through MRI. Reading by Low Power Radio. Reading by GSM/GPRS/PSTN. 11/10/
32 Electronic Meter Reading Methods Direct Reading by MRI Meter reader required to read meter at a particular location Communication Cable Electronic Meter MRI compatible with Meter Vendor software Power Pack unit used when Power is off to power up meter 11/10/ Meter data is stored in MRI
33 Meter Data Downloading After Reading the Meter its Data can be downloaded in respective BCS( Base Computer Software). This data contains all the data like Instantaneous, Billing, Load Survey, Event & Transaction data. File name extension of data is.mrd 11/10/
34 Base Computer Software (BCS) Meter make BCS 1. Secure Smart2k 2. L&T Vincom 3. PRI UK Integrator 11/10/
35 SMART 2000 Base Computer Software 11/10/
36 Overview Smart 2K Stands for Secure Meters Analysis & Reporting Tool. SMART 2000 is BCS (Base Computer Software) part of Integrated metering system Energy Meter BCS ( Base Computer Software) MRI ( Meter Reading Instrument) It records energy, electrical parameters, tamper and load survey data. It collects data from the meters using MRI or with modem & telephone line (RMR). These data may be used for analysis and monitoring with the help of Smart 2000 analysis and report tool. Smart 2000 works on Windows platform. Older version working on DOS was Sems Pack. 11/10/
37 Features Gives logical view of all the meter reading data according to various parameters like: Instantaneous parameter, Current energy & bill energy data, Time of day energy register data, MDs, Abnormal electrical condition data Perform various other operations called transactions on the meter like Authenticated MD reset, update Date & Time, Tariff, etc. Organized storage of meter reading data and consumer data. New user(s) with their level of access rights could be defined and / manage by supervisor based upon their usage. 11/10/
38 Features (Contd ) Exporting the meter data in the industry standard common formats (like ASCII, CSV) so data can be used by other software for billing or otherwise. Load survey information is displayed graphically whereby user has an option to see multiple parameters on the same graph or on a separate view. All the information displayed on the screen can be printed and permanent record can be maintained. Customer can choose what is to be printed. Selection on category such as Energy, Survey, Transaction, etc or on subcategory such as Main energy, Bill energy, TOD energy, history of energy registers etc. 11/10/
39 Smart 2000 Main Screen 11/10/
40 Main Menu Centre Window Right Hand Side Window Left Side Window Status Bar 11/10/
41 Main Menu - General 11/10/
42 Upload data in Smart2k 11/10/
43 Upload data in Smart2k 11/10/
44 Different Mode for Meter Selection 11/10/
45 Meter Selection Reading Date, Consumer Detail and MRD Path of Selected Meter 11/10/
46 Analysis Report To view the following parameters double click on the selected meter s MRD file: Instantaneous Parameter Energy Values Load Survey Events Report Transaction 11/10/
47 Instantaneous Parameters We can view Instantaneous Parameter in two different ways Tabular View Date & Time Frequency Voltage Line Current Active Current Reactive Current Power Factor Active Power, Apparent Power, Reactive Power Average Power Factor Phasor Diagram 11/10/
48 Instantaneous Parameters 11/10/
49 View - Energy Values Divided into three category - General, Energy & Demand General is divided into seven different view General, Bill Dates, Flags, Power ON/OFF, Power Factor, TOD PF, Tamper Count. Energy Main energy, TOD energy, Consumption, Mid-Night data, TOD consumption. Demand Max demand, TOD, CMD 11/10/
50 View - Energy Values 11/10/
51 View - Energy Values 11/10/
52 View - Energy Values 11/10/
53 View - Energy Values 11/10/
54 View - Energy Values 6 no. History s cumulative Energy is present 11/10/
55 View - Energy Values History 1 TOD Registers- 8 no. TOD Registers 11/10/
56 View - Energy Values Consumption between two Histories 11/10/
57 View - Energy Values Max Demand for History 1 with date and time 11/10/
58 View - Energy Values Daily Energy values at midnight 11/10/
59 View Load Survey With Mouse movement on the graph we could see particular IP value Keep the scaling fixed from page to page Select the color of your choice Select the graph of your choice Convert load survey data into text file Five different graphs Demand, Energy, Voltage, Current, Power Factor. 11/10/
60 View Load Survey No. of Parameter Depends on meter Clem and utility requirement 11/10/
61 View Load Survey Time Slot 11/10/
62 View Load Survey 11/10/
63 View Load Survey 11/10/
64 View Events Could see the following tamper of your interest: R-Ph, Y-Ph, B-Ph missing potential R-Ph, Y-Ph, B-Ph missing current Power Failed See tamper with snapshot & summary details such as tamper count & duration for which meter has remained under tamper Convert the tamper data into text file 11/10/
65 View Events 11/10/
66 View Events 11/10/
67 View Events Count of Tamper and cumulative time 11/10/
68 Convert Wizard (Multiple Meters Data Conversion) 11/10/
69 Why Convert Wizard is used Converted files of meter data can be opened in notepad or MS-Excel for further analysis. Multiple meters converted files are large in number which may further be imported in third party software to get metering information Report. 11/10/
70 Main Menu - Data Check parameter which is to be converted 11/10/
71 Converted Data file- Load Survey Each Half hour 8 no. Parameters are logged Each Half hour data is logged 11/10/
72 Converted Data file- Tamper Event B Phase voltage at occurrence and restoration of event B phase missing potential is easily seen with time stamped 11/10/
73 Converted Data file- Instantaneous Time Drift found All Parameters are instant parameters at time of reading 11/10/
74 Converted Data file- Energy History 1 parameter along with billing date and time, billing energy and billing MD may be found 11/10/
75 Converted Data file- Midnight Daily midnight energy data can be found 11/10/
76 Converted Data file- Transaction No transaction with meter is done after 6/8/ /10/
77 System Configuration Operating Systems: Window 98, Window 2000, Windows XP Minimum hardware configuration: Celeron 550 MHz / P-III based PC with 64 MB of RAM. 20 GB hard disk space for software and for storing meter reading data. A color monitor with 1024 X 768 resolution is required. CD drive (32X or higher) is required to install the software. An external modem is must in case you plan to use the remote meter reading feature. COM port 11/10/
78 Security SMART2K - Benefits Uses unique security keys to validate meter data for its authenticity. Create levels of user with different rights. It has its own database where consumer, metering information like meter no, CT PT ratio, address and EMF can be stored. Used for meter data analysis. Backward compatibility for all the meters made by SML Meter reading Direct meter reading without MRI can be done Manual / automatic reading at predefined time Modem sharing possible 11/10/
79 Export meter data SMART2K - Benefits Select what is to be exported Field width, Decimal digits, Order in which parameter should appear etc File format such as text file, spreadsheet file, database file etc Back up facility of Meter database and Meter data files On line data monitoring can be done. 11/10/
80 Questions Please 11/10/
Power Log PC Application Software
Power Log PC Application Software Users Manual May 2007 Rev. 1, 5/08 2007-2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationCart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationTechnical Notes TN 1 - ETG 3000. FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?
FactoryCast Gateway TSX ETG 3021 / 3022 modules How to Setup a GPRS Connection? 1 2 Table of Contents 1- GPRS Overview... 4 Introduction... 4 GPRS overview... 4 GPRS communications... 4 GPRS connections...
More informationPower Log PC Application Software
Power Log PC Application Software Users Manual May 2007 Rev. 3, 3/13 2007-2013 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Fluke Corporation
More informationT-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
More informationUser Guide Win7Zilla
User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main
More informationAlliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
More informationHyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
More informationUser s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
More informationUser s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationUser Manual WatchPower
User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...
More informationHydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
More informationThe software solution to complete your flow monitoring program
The software solution to complete your flow monitoring program Flowlink 5.1 software is the central point of your flow data management program. With this software you can: Configure Isco equipment on-site
More informationAPPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS
APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...
More informationRemote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos
Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos (Remote monitoring of data in the Millenium 3 using SL-In/SL-Out function blocks) Your partner for industrial
More informationModel 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
More informationQuick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationFrequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
More informationRemote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos
Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos HMS Industrial Networks AB Page 1 (37) History Revision Date Description Responsible 1.11 2012-09-26 Typos SDA
More informationEco-POWER METER Data Collection Software KW Monitor Operation Manual
Eco-POWER METER Data Collection Software KW Monitor Operation Manual Software version: KW Monitor V2.70 Issued on January 2014 Table of Contents Chapter 1 Introduction...1 Chapter 2 Main functions of KW
More informationPMS. Energy management and monitoring software. Installation and operation instructions
PMS Energy management and monitoring software Installation and operation instructions version 1.0 Czech Republic Czech Republic 1 Content 1. PMS introduction... 3 1.1. PMS structure... 3 1.2. System requirements...
More informationModel SL355 Noise Dosimeter/Datalogger
Model SL355 Noise Dosimeter/Datalogger Software Help Guide Software Introduction The SL355 Noise Dosimeter software allows for setup and retrieval of recorded data in the Noise Dosimeter. A total of 20
More informationSA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
More informationCRE Monitor Instructions Manual
CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility
More information3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
More informationKM Metering Inc. EKM Dash 1.8.3.0 User Manual. EKM Metering Inc. www.ekmmetering.com info@ekmmetering.com (831)425-7371
EKM Dash 1..3.0 User Manual The EKM Dash is our desktop software solution for your meter data management. It is intended to give you the tools to easily visualize, log, email, and export your data in a
More informationUser Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
More informationKorosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
More informationRogue RE-CONN Utility
Rogue RE-CONN Utility Rogue s RE-CONN software is a utility that enables remote communication with compatible Rogue devices, using a Windows-based PC and a DCV-0001 data converter. With this utility you
More informationINTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series
Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)
More informationLEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
More informationTime Attendance V1.4
Time Attendance V1.4 Installation Manual May 11, 2011 Page 1 TABLE OF CONTENTS 1. TIME ATTENDANCE...5 2. SOFTWARE INSTALLATION...6 3. SETTING UP THE TIME ATTENDANCE SYSTEM...7 3.1 Set Password...7 3.2
More informationOverview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationCMS Central Monitoring System
General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System
More information5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual
5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine
More informationUltra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
More informationWA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
More informationInstalling the IF-NMEASC & SC30 Windows XP Drivers & Software
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:
More informationApplication Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
More informationTemperature Datalogger Users Manual
Temperature Datalogger Users Manual Page 1 TABLE OF CONTENTS FEATURES & SPECIFICATIONS... 3 APPLICATIONS... 4 START UP AND GENERAL OPERATION... 5 LCD Display... 5 Turn On Temperature Data Logger... 6 Switch
More informationCounter for Energy. We make energy measurable and secure your future. www.g-mw.de
Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of
More informationDriver Pant 8 and antenna switcher Ant 8. User manual
Driver Pant 8 and antenna switcher Ant 8 User manual Table of contents Table of contents... 2 Introduction... 3 Shipping Contents... 3 Technical Data... 3 Control Panel... 4 Rear panel... 5 Controller
More informationLOVELINK III- Process Monitoring, Logging, Graphing, & Configuration
LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration VERSION 1.00.00 USER MANUAL Updated 09/13/2002 Table of Contents Hardware/Software Requirements...2 Computer Requirements...2 Instrument
More informationF453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
More informationFile Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
More informationPROMIS Tutorial ASCII Data Collection System
This Promis tutorial explains on a step by step base how to setup a basic data collection system capturing data from data acquisition sources outputting ASCII strings. For this tutorial we used a Ontrak
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationTitelgrau belassen! Leere Vorlage
Titelgrau belassen! Leere Vorlage MAVOWATT 20 Energy Platform Energy and Power Analyzer MAVOWATT 20 The new Energy and Power Analyzer 2 Klaus-Peter Richter Product Management 10.3.2010 Page 2 Applications
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationSentry4 NJEX Odorant System Software Operators Manual. Remote operation Documented audit trail Analyzing and reporting graphs
NJEX Odorant System Software Operators Manual Remote operation Documented audit trail Analyzing and reporting graphs Page 1 10/25/2007 Page 2 10/25/2007 Information contained in this document is subject
More informationDAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationMetering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
More informationDICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:
PR100/PR300/PR500 Pressure Logger Operation Contents: Product Applications and Useful Features Product Specifications Operating Instructions / Getting Started DicksonWare Software Specifications Product
More informationVehicle Tracking System,
Vehicle Tracking System, The Complete Solution What is GPS? Product Review. Complete system. Contact Us. What is GPS? GPS, which stands for Global Positioning System, is the only system today able to show
More informationGUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 info@guard1.com www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
More informationPROMIS Tutorial MODBUS Data Collection System
This Promis tutorial explains on a step by step base how to setup a basic MODBUS data collection system. For this tutorial we used a Novus DigiRail4C digital counter input module configured for energy
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationBack Office Recorder 4iP Installation Guide Intelligent Recording Limited
Back Office Recorder 4iP Installation Guide Intelligent Recording Limited Downloads Available at www.usbcallrecord.com UK Office +44 (0) 1909 512148 US Office +1 949.587.1226 Copyright Intelligent Recording
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More information5000V Graphical Megohmmeter Model 5070
5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated
More informationManual. Sealer Monitor Software. Version 0.10.7
Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3
More informationAdminToys Suite. Installation & Setup Guide
AdminToys Suite Installation & Setup Guide Copyright 2008-2009 Lovelysoft. All Rights Reserved. Information in this document is subject to change without prior notice. Certain names of program products
More informationAdditional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
More informationTR-3 Channel Editor. Software Manual
TR-3 Channel Editor Software Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed
More informationTable of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..
Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2
More informationUser's Guide DylosLogger Software Version 1.6
User's Guide DylosLogger Software Version 1.6 The DylosLogger software allows users of Dylos Air Quality Monitors equipped with PC interface to easily record, download, and graph data. The COM port is
More informationDME4 V1.23 (06-1999) V1.30 (06-2000) V1.31 (04-2001) V1.32 (09-2001) V1.33 (03-2002) V1.34 (06-2003) V1.35 (05-2004) V2.00 (12-2005) V2.
DME4 V1.23 (06-1999) - Correction of unfounded error message 'No measurements configured' when reading measurements from DME440 (MODBUS) if special measurands hadn't been selected to be calculated. - Correction
More informationEnsto Chago Master EVM300 and EVM500 Operational description
Pages: 1 (8) Ensto Chago Master EVM300 and EVM500 Operational Pages: 2 (8) Contents 1 What is Ensto EVM... 3 2 EVM versions... 3 2.1 EVM300... 4 2.2 EVM500... 5 3 Technical information... 7 Pages: 3 (8)
More informationACS CLIENT SOFTWARE USER MANUAL
ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB
More informationModbus RTU (RS-485) TCP/IP (Ethernet)
Eaton Innovative Technology PEM PC Software Installation and Operation Instruction Manual: IM01005006E Rev. 2 March 2007 Modbus RTU (RS-485) TCP/IP (Ethernet) Effective Date 3/2007 For more information
More informationRGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units
I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data
More informationHow to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
More informationSW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards
SW43W FlukeView Power Quality Analyzer Software Version 3.20 onwards Users Manual 4822 872 30778 December 2005, Rev.1, 04/06 2005 Fluke Corporation, All rights reserved. All product names are trademarks
More informationOWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
More informationHandheld LPC Utility Software for Windows. Operation Manual
Handheld LPC Utility Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual handy
More informationPMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán 17 77900 Olomouc Czech Republic
PMS Energy management and monitoring software Installation and operation instructions version 1.5 77900 Olomouc 1 Content 1. PMS introduction...3 1.1. PMS structure...3 1.2. System requirements...3 2.
More informationHoneywell Internet Connection Module
Honeywell Internet Connection Module Setup Guide Version 1.0 - Page 1 of 18 - ICM Setup Guide Technical Support Setup - Guide Table of Contents Introduction... 3 Network Setup and Configuration... 4 Setting
More informationRemote Backup Software User Manual V 2.0
Remote Backup Software User Manual V 2.0 Table of Contents Chapter 1 Welcome to Remote Backup Software... 2 1.1 Overview... 2 1.2 Computer Disposition Request... 2 1.3 Convention... 2 Chapter 2 Installing
More informationProduct Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
More informationHow To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
More informationDCS110 CATVisor COMMANDER
Broadband Cable Networks April 13, 2006 1(5) DCS110 CATVisor COMMANDER Introduction CATVisor Commander is the standalone software tool for configuring, adjusting and monitoring Teleste Headend and HFC
More informationDUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationEVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
More informationOlson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
More informationCX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00
CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard
More informationSiloPatrol. SiloTrack Inventory Management Software Version 3.5 BULLETIN 343B. Interface With Multiple Sensor Technologies
Setting The Standard For Supplier Excellence SiloPatrol SiloTrack Inventory Management Software Version 3.5 Interface With Multiple Sensor Technologies Simple Local And Remote User Access Vendor/Remote
More informationKACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data
KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production
More informationV2.0 Attendance System Hardware Suite Guide Instructions Manual
CONTENTS TA920 V2.0 Attendance System Hardware Suite Guide Instructions Manual Chapter One - Introduction 1.1 Communication Port 5 1.2 Power Source Control. 5 1.3 Attendance Users. 6 1.4 Registering Ways..
More informationTable Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
More informationEnergy meters For an efficient control of energy consumption
Energy meters Energy meters For an efficient control of energy consumption In a modern world in which energy must be monitored and controlled in the most efficient way possible, LOVATO Electric presents
More informationDAKTON µ BOX MANUAL µbox User Manual 1
µbo User Manual 1 DAKTON µ BO: compact data logger and sensor µ BO is a sensor and a data logger together. It records data processed by DAKTON DASHBOARD with the addition of lateral and longitudinal accelerations.
More informationGSM Interfacing Board
Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from
More information