1 T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: Version 1.0

2 Content 1. Purpose of this document T-BoxN12R overview First step Preparing your workshop to start quickly Powering up your T-Box Installing software Connecting T-Box to your PC Configuring security See how your T-Box works Example application Blinker Start and configure Hyper Terminal See how blinker switches outputs See how blinker reads inputs Manage Java IMlet applications User control mode How to start? User Control Mode configuration Reference... 16

3 1. Purpose of this document Purpose of this document is to help users and integrators to quickly start integrating and using the T- BOXN12R (hereafter T-Box). This document describes how to connect T-Box to external hardware, personal computer and how to set it up for testing and operation. The reader of this document should be familiar with the documents listed on reference page.

4 2. T-BoxN12R overview T-BOX/N12R is a terminal with GSM connectivity. T-BOX/N12R module is designed using most advanced solutions from Nokia. It has a built-in Nokia 12 modem for data transfer. So, various data transfer channels of GSM can be used. In this way, we can offer you most reliable connection for the best price. T-BOX/N12R operates in any GSM network: 900/1800 MHz or 850/1900 MHz. EDGE, GPRS, HSCSD, CSD and SMS could be used for data transfer*. T-BOX/N12R can be used as a remote control unit, data collection and transfer unit. Discrete outputs can be use to manage external loads like relays, lights etc. Discrete inputs can be used to monitor the status of external devices. The inputs are optically isolated. Analog inputs enable to mease the static signals like voltage, current, temperature, etc. T-BOX/N12R can be used as a small and very simple logical controller. T-BOX/N12R includes Java with remote IMlet downloading. It means that this controller can be programmed according consumer requirements with standard and easy available tools. Integrated TCP/IP stack enables to make an IP connection to remote servers or modules. It is a very easy to send and receive data. Integrated CORBA support allows creating distributed applications. Module also includes an interface for connecting a GPS receiver, which is necessary for location acquirement applications. This device can be used as a modem for PC as well. Also you can control the external devices connected via RS-232 interface. Wide range of power supply voltage and operating temperature range expands the possibilities. The T- Box case is suitable for fitting with electronic instruments that can hook to the DIN EN T- BOX/N12R is small in size, but big in its functionality, what lets you easily control your machines.

5 3. First step 3.1. Preparing your workshop to start quickly This chapter explains what you need to start working with T-Box. Most needed tools are on CD which is supplied with T-Box. To start and configure T-Box you need: 1. T-BoxN12 Sample 2. Cables (included with T-BoxN12R) Two cables are shipped with T-Box. The first one is called Port 1/2 and second one - Port 3. Cable labels match port names of Nokia 12 GSM module. 3. Power supply Power supply should be: 6 to 30 V DC, 1A. (500mA@12V). 4. PC with Microsoft Windows operating system Requirements: any IBM PC compatible machine which fits OS requirements. 5. Nokia 12 Configurator Software This software is shipped on the CD with T-Box. You can also check Nokia s web site for updates Powering up your T-Box Connect power supply to power connector of T-Box. See labelling on T-Box housing. Polarity is important be careful not to swap positive and negative terminals. T-Box has an integrated protection for wrong power connection Installing software In order to start working with T-Box, you must install Nokia 12 Configurator Software, which is found on the CD, at first. To start the installation process log in to your computer as a user with appropriate permissions. Start Nokia_12_Configurator_2.40.exe (version might be different) and follow the screen messages. You must agree with license and press button Next a few times.

6 3.4. Connecting T-Box to your PC Connect cable labelled Port1/2 to T-Box port labelled Port2/3 and to COM port of your PC. This will let you configure T-Box via M2M interface. Configure Nokia 12 Configurator to use COM port to which the T-Box is connected and set connection type to M2M System Interface. Figure 1 Nokia 12 Configurator software setup is shown Figure 1. After setting these parameters press OK and wait a while until Configurator connects to T-Box. When connection is successful you should see a dialog box asking to enter PIN code. This dialog box is shown below in Figure 2. Figure 2 PIN code should be provided by your GSM provider, it is a four digit code. PIN code depends on the SIM card you use. Note: Usually each SIM card has its own PIN code.

7 After you enter the PIN code you will see your GSM operator s name and a green/blue connector in the lower right corner of the Configurator window: Menu for configuration Operators name and signal strength Connection OK 3.5. Configuring security Nokia 12 module supports GSM security codes, AutoPIN and live checks with reset mechanisms, to enhance the reliability and security of the M2M application. You can configure T-Box security in GSM Security> PIN Code Settings menu: Figure 3 PIN Code Settings

8 Change the PIN code query in the PIN Code Settings dialog. The available settings are: On (PIN code query On): Every time the T-Box is started, the PIN code is queried. Off (PIN code query Off): The PIN code query is disabled. Auto (AutoPIN): The PIN code is stored into the memory of the Nokia 12 GSM Module during the first start-up. In later start-ups the T-Box automatically enters the PIN code for the current SIM card. AutoPIN enables device recovery after (occasional) power cuts without on-site intervention, and helps to prevent fraud. The PIN code is programmed into the memory of the Nokia 12 module where it is relayed in unusual situations. When AutoPIN is in use, the SIM card is useless to any outsider.

9 4. See how your T-Box works The T-Box samples are shipped with preloaded demo Java application. This application is called Blinker. This section describes the functionality of blinker application Example application Blinker Blinker application writes 1s and 0s every 0,5 s and you will see that on blinking LEDs. Then it logs the state of digital and analog inputs to Java port (Port 3 Nokia 12). To see how Blinker works you should connect PORT 3 of T-Box to some of the COM ports of your PC. You should use cable labelled PORT 3 connected to T-Box on port labelled PORT2/3. Note: PORT 2 and PORT 3 of Nokia 12 GSM Module are connected to one connector of T-Box labelled PORT 2/3. To use PORT 2, use cable labelled PORT1/2. To use PORT 3, use cable labelled PORT Start and configure Hyper Terminal Hyper Terminal is a standard Windows application, it can be found in Start> Programs> Accessories> Communication menu. When you start Hyper Terminal it will ask you for configuration: First enter connection name. Connection name is defined by user:

10 After you press OK you have to choose the COM port to which T-Box is connected. Then you have to set up COM port parameters as following:

11 After you press OK you should see something like this: Values can be different See how blinker switches outputs When Blinker application is running, LEDs on front panel of T-Box should blink in sequence. Also outputs are switched. You can see how outputs are switched in the following simple schematic: T-BOX 200Ω Output LED 1k 12V 4.4. See how blinker reads inputs When T-Box connected to a PC via PORT3 to COM port, you can see the state of inputs with Hyper Terminal. To change the state of the inputs you should apply for example 12V between input and input ground. Note: Inputs are optically isolated and have separate ground. Input ground has this sign:

12 Connection schematic should be the following: + 12V - IN x where x is the number of T-Box input. False. When voltage is applied, input state will change to True, when there is no voltage, the state will be 4.5. Manage Java IMlet applications T-Box (Nokia 12 GSM Module) has 1Mbyte memory for application and data storage. This memory can be used for storing IMlets or data files. One IMlet application can be up to 128Kb in size. But you can load as much IMlets as you want until you have enough memory. Only one IMlet can run at a time. One IMlet can start another IMlet. IMlets are managed with Nokia Configuration software. You can run IMlet loading application in Nokia Configurators menu IMlet Loading > Cable: You can stop and start an IMlet here. Delete or load new application Check how much memory left on module Figure 4 IMlet loading suite If you don t need demo application in your T-Box, you should simply delete it. Note: Before deleting an IMlet stop it with stop button!

13 5. User control mode 5.1. How to start? First you should stop or delete a demo application. Start Nokia Configurator as it is described in section 3.4. Start IMlet loading suite as it is described in section 4.5 an stop an IMlet if it is running. To see which IMlet is active simply click on each IMlet available in the list and look at the Stop and Start buttons. If Stop button is active, it means that current IMlet is running User Control Mode configuration In Nokia 12 Configurator Software select User Control Mode > Settings. You should see the following window: Figure 5 User Control Mode Setup window First step is to enter an identifier in identifier field. Click Change, enter identifier and click Accept.

14 Note: Remember to click Write Parameters button after every change of parameters! When identifier is entered General, Security and Aliasing tabs are enabled. Note: If identifier is already entered and dabs are still disabled, click Read Parameters button Purpose of tabs: General tab Here you can enable or disable acknowledgements. They are used to send confirmation to user about performed commands. Security tab - Configure security options: Enter password here Enter authorized numbers here. The firs number in the list is a special one. Owner of this number will receive all failed commands sent so Nokia 12.

15 Aliasing tab here you can enter an alias for each input and output. This helps better to remember the functionality of the command. For example So in this case instead of writing OUTPUT_SET 5 ON you should just write Heating ON. When all the parameters are entered click Write Parameters. Now test how it works. Suppose identifier is IDF and password is PSW, then send the following message to your T-Box: IDF PSW Heating ON Message format is: <identifier> <PSW> <Command> For more information about User Control Mode refer to #3.

16 6. Reference Recommended literature 1. T-BoxN12r Integrators Manual Available documents from 2. Nokia 12 Hardware Integration Manual 3. Nokia 12 Remote IO Control Guide 4. Nokia M2M Platform Nokia 12 GSM Module IMlet Programming Guide 5. Nokia M2M Platform Software Developer s Guide 6. Nokia 12 GSM Module Product Specification

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2] SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

MT-350 SMS. Operation Manual. PORTech Communications Inc.

MT-350 SMS. Operation Manual. PORTech Communications Inc. MT-350 SMS Operation Manual PORTech Communications Inc. Index 1.Hardware Setup...1 2.Software Setup...1 3.Operation Guide...2 4.How to send out a short message...3 5.Report File...6 6.Q & A...6 MT-350

More information

Quick Installation Guide DIR-620. Multifunction Wireless Router Supporting GSM, CDMA, WiMAX with Built-in 4-port Switch

Quick Installation Guide DIR-620. Multifunction Wireless Router Supporting GSM, CDMA, WiMAX with Built-in 4-port Switch DIR-620 Multifunction Wireless Router Supporting GSM, CDMA, WiMAX with Built-in 4-port Switch BEFORE YOU BEGIN Delivery Package Multifunction wireless router DIR-620 Power adapter DC 5V/2.5A Ethernet cable

More information

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Application Note: Connecting to a 2500 Series Processor using PLC Workshop Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The

More information

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03 smart-house Web-Server Manual Version 1.03 CARLO GAVAZZI HANDEL A/S, Over Hadstenvej 42, DK-8370 Hadsten, Danmark Tlf. 89 60 61 00, Fax 86 98 15 30, Reg.nr. 65 206 Internet: http://www.carlogavazzi.com/ac/dk

More information

Huawei E169 & E220 Status Lights

Huawei E169 & E220 Status Lights Huawei E169 & E220 Status Lights 3G Wireless Troubleshooting Connection Issues 1. Have you correctly inserted the SIM card into the USB Modem? Please ensure the SIM card is correctly inserted. The gold

More information

Premium Server Client Software

Premium Server Client Software Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management

More information

Inserting the SIM card in the MobiGater device. Connecting the MobiGater Device

Inserting the SIM card in the MobiGater device. Connecting the MobiGater Device WWW.MOBIGATER.COM 2 Inserting the SIM card in the MobiGater device There is a small cover on the bottom side of the MobiGater device Move the cover in the direction from? to. Move the SIM card holder in

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

ALARM MONITORING & CONTROL SYSTEM TWCT22 USER MANUAL 1.1

ALARM MONITORING & CONTROL SYSTEM TWCT22 USER MANUAL 1.1 ALARM MONITORING & CONTROL SYSTEM TWCT22 USER MANUAL 1.1 UAB TELTONIKA Saltoniskiu str. 10C, LT-08105, Vilnius, Lithuania Phone: +370 5 2127472 Fax: +370 5 2761380 info@teltonika.lt www.teltonika.eu Legal

More information

32 Transferring Projects and Data

32 Transferring Projects and Data 32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1

More information

GPS Vehicle and personal location tracker. User manual

GPS Vehicle and personal location tracker. User manual GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...

More information

USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0, 2014.8.1

USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0, 2014.8.1 USB GSM 3G modem RMS-U-GSM-3G Manual (PDF) Version 1.0, 2014.8.1 2014 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in

More information

Technical Notes TN 1 - ETG 3000. FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

Technical Notes TN 1 - ETG 3000. FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection? FactoryCast Gateway TSX ETG 3021 / 3022 modules How to Setup a GPRS Connection? 1 2 Table of Contents 1- GPRS Overview... 4 Introduction... 4 GPRS overview... 4 GPRS communications... 4 GPRS connections...

More information

GE Security. FHSD Monitor / Web Server user manual

GE Security. FHSD Monitor / Web Server user manual GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5 Technical Manual (TLT-2H GPS/GSM Vehicle Tracker) V1.5 Product main features Real-time SMS query coordinates time position, Phone Position active help feature speed alarm function historical data uploading

More information

DVG-2101SP VoIP Telephone Adapter

DVG-2101SP VoIP Telephone Adapter This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DVG-2101SP VoIP Telephone Adapter Before You Begin 1. If you purchased this VoIP Telephone

More information

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table

More information

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate

More information

Config software for D2 systems USER S MANUAL

Config software for D2 systems USER S MANUAL DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------

More information

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

This document is intended to make you familiar with the ServersCheck Monitoring Appliance ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other

More information

Kaseya 2. Quick Start Guide. for Network Monitor 4.1

Kaseya 2. Quick Start Guide. for Network Monitor 4.1 Kaseya 2 VMware Performance Monitor Quick Start Guide for Network Monitor 4.1 June 7, 2012 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private

More information

Teltonika FM41XX. Configurator v. 1.0

Teltonika FM41XX. Configurator v. 1.0 Teltonika FM41XX Configurator v. 1.0 1. First steps Connect Teltonika FM41XX (PIN1 for plus and PIN11 ground ) to the voltage supply 10-30 V as shown below and GPS, GSM antennas. (GSM is long and thin,

More information

Quick Installation Guide DSL-2750U. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Quick Installation Guide DSL-2750U. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch DSL-2750U 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch BEFORE YOU BEGIN Delivery Package Router DSL-2750U Power adapter DC 12V/1A RJ-11 telephone cable Ethernet cable (CAT 5E) Splitter (brochure).

More information

SMS Database System Quick Start. [Version 1.0.3]

SMS Database System Quick Start. [Version 1.0.3] SMS Database System Quick Start [Version 1.0.3] Warning ICP DAS Inc., LTD. assumes no liability for damages consequent to the use of this product. ICP DAS Inc., LTD. reserves the right to change this manual

More information

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch DSL-2750U/NRU 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch BEFORE YOU BEGIN Delivery Package Router DSL-2750U/NRU Power adapter RJ-11 telephone cable Straight-through Ethernet cable (CAT 5E)

More information

Supervisor 10 Remote Access Users Guide Last Update: 10/27/14

Supervisor 10 Remote Access Users Guide Last Update: 10/27/14 1996 Lundy Ave 95131 Tel: (408) 519 2062 Fax: (408) 519 2063 Supervisor 10 Remote Access Users Guide Last Update: 10/27/14 www.anacominc.com Remote Access describes a procedure by which a user running

More information

IntraVUE Plug Scanner/Recorder Installation and Start-Up

IntraVUE Plug Scanner/Recorder Installation and Start-Up IntraVUE Plug Scanner/Recorder Installation and Start-Up The IntraVUE Plug is a complete IntraVUE Hardware/Software solution that can plug directly into any network to continually scan and record details

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

SUPPORT GUIDE FOR. NOKIA MODEM DRIVER AND DIAL-UP for the Nokia 610. Copyright Nokia. All rights reserved Issue 0.4

SUPPORT GUIDE FOR. NOKIA MODEM DRIVER AND DIAL-UP for the Nokia 610. Copyright Nokia. All rights reserved Issue 0.4 SUPPORT GUIDE FOR NOKIA MODEM DRIVER AND DIAL-UP for the Nokia 610 Copyright Nokia. All rights reserved Issue 0.4 Contents 1. INTRODUCTION...1 2. SYSTEM REQUIREMENTS...1 3. INSTALLING THE NOKIA 610 MODEM

More information

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance

More information

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A)

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A) 2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A) Contents 1 Description... 3 1.1 SIM900... 5 1.2 Features... 6 1.3 Specifications for Fax... 6 1.4 Specifications for SMS via GSM/GPRS...

More information

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) Hardware Installation 1. Initial placement for programming and configuration purposes should be performed in an indoor environment.

More information

Amcrest 960H DVR Quick Start Guide

Amcrest 960H DVR Quick Start Guide Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and

More information

Ethernet Radio Configuration Guide

Ethernet Radio Configuration Guide Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

The service note describes the basic steps to install a ip camera for the DVR670

The service note describes the basic steps to install a ip camera for the DVR670 Tech note Description Adding IP camera to DVR670 General The service note describes the basic steps to install a ip camera for the DVR670 Steps involved: 1) Configuration Manager application 2) Camera

More information

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04. DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must

More information

Short Manual Intellect v.4.7.6 SP2 module Unipos Contents:

Short Manual Intellect v.4.7.6 SP2 module Unipos Contents: Short Manual Intellect v.4.7.6 SP2 module Unipos Contents: 1. Software Installation... 2 2. Hardware Configuration... 12 3. System Dispatching... 14 3.1. Create dispatching objects... 14 3.2. Graphical

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To

Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To Dial-up Networking (DUN) allows a computer or other device to use your AirLink modem to connect to the Internet or private

More information

TPG MOBILE BROADBAND QUICK SETUP GUIDE

TPG MOBILE BROADBAND QUICK SETUP GUIDE TPG MOBILE BROADBAND QUICK SETUP GUIDE TPG USB E1762 Modem Thank you for choosing TPG Mobile Broadband and USB E1762 modem. This User Guide provides step by step instructions that will take you through

More information

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW-50040. Quick Installation Guide

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW-50040. Quick Installation Guide 50-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-50040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4. Terminal

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

The irnetbox Manager User Guide

The irnetbox Manager User Guide The irnetbox Manager User Guide Chris Dodge RedRat Ltd April 2014 For irnetbox Manager 3.05 1 Contents 1. Introduction...3 2. Initial Network Configuration...3 3. Finding irnetboxes...3 3.1 Device Information

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

ScanWin Installation and Windows 7-64 bit operating system

ScanWin Installation and Windows 7-64 bit operating system ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

Quick Installation Guide DAP-1360. Wireless N 300 Access Point & Router

Quick Installation Guide DAP-1360. Wireless N 300 Access Point & Router DAP-1360 Wireless N 300 Access Point & Router BEFORE YOU BEGIN Delivery Package Access point DAP-1360 Power adapter DC 12V Ethernet cable (CAT 5E) (brochure). If any of the items are missing, please contact

More information

9236245 Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

9236245 Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation 9236245 Issue 2EN Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia 9300 Configuring connection settings Legal Notice Copyright Nokia 2005. All rights reserved. Reproduction,

More information

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15 Printer - Replacement The following is a guide on how to swap out a WIC printer with another. A scenario where this might happen is when getting a service replacement for faulty hardware from Source Technologies.

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

INTELLECT TM Software Package

INTELLECT TM Software Package AxxonSoft INTELLECT TM Software Package Quick Start Guide Version 1.0.0 Moscow 2010 1 Contents CONTENTS... 2 1 INTRODUCTION... 3 1.1 Document purpose... 3 1.2 Purpose of the Intellect software package...

More information

ON-GUARD. Guard Management System. Table of contents : Introduction Page 2. Programming Guide Page 5. Frequently asked questions Page 25 - 1 -

ON-GUARD. Guard Management System. Table of contents : Introduction Page 2. Programming Guide Page 5. Frequently asked questions Page 25 - 1 - ON-GUARD Guard Management System Table of contents : Introduction Page 2 Programming Guide Page 5 Frequently asked questions Page 25-1 - Introduction On Guard tm is designed to exceed all the requirements

More information

DSX-HSCS Hot Swap Comm Server

DSX-HSCS Hot Swap Comm Server DSX Access Systems, Inc. DSX-HSCS Hot Swap Comm Server WinDSX Hot Swap Redundancy Software Hot-Swap Redundant Communications Server provides continued availability of System Communications and Control

More information

Brady IP Printer Installation Instructions

Brady IP Printer Installation Instructions Brady IP Printer Installation Instructions Ensure the following are available before commencing installation: The IP Printer and accessories (Printer, power cable, Product CD including Windows printer

More information

Chapter 1 Installing the Gateway

Chapter 1 Installing the Gateway Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information

More information

English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list

English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list LW320/LW321 Sweex Wireless 300N Router Do not expose the Sweex Wireless 300N Router to extreme temperatures. Do not place the device in direct sunlight or in the direct vicinity of heating elements. Do

More information

X Series Application Note 43:

X Series Application Note 43: X Series Application Note 43: Using the Remote Viewing & Web Pages of the X - Series & GR Series Recorders The Remote Viewing function of the X-Series and GR Series Recorders provide the user with the

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

PowerShield SNMP Adaptor

PowerShield SNMP Adaptor PowerShield SNMP Adaptor This manual describes the setup and operation of the PowerShield SNMP adaptor for the Sentinel battery monitoring system 6300-079A SNMP User Manual Page 1 of 9 1. Connecting the

More information

User Guide HUAWEI UML397. Welcome to HUAWEI

User Guide HUAWEI UML397. Welcome to HUAWEI User Guide HUAWEI UML397 Welcome to HUAWEI 1 Huawei UML397 4G LTE Wireless Modem User Manual CHAPTER 1 BEFORE USING YOUR UML397 WIRELESS MODEM ABOUT THIS USER MANUAL...4 WHAT S INSIDE THE PRODUCT PACKAGE...4

More information

GSM-AUTO+ GSM Controller with Internal Power Supply User manual

GSM-AUTO+ GSM Controller with Internal Power Supply User manual GSM-AUTO+ GSM Controller with Internal Power Supply User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 6 Quick reference of

More information

EPSON Scan Server & EPSON TWAIN Pro Network

EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network SCANNER UTILITY PROGRAMS All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity SMS Alert Controller Version 7 [Windows XP/Vista/7] GSMS THR / GSMS THP Revision 110507 [Version 2.2.14A] ~ 1 ~ SMS Alarm Messenger Version 7 [Windows XP/Vista/7] SMS Pro series

More information

USER S MANUAL. Settop Cell-Xtrem

USER S MANUAL. Settop Cell-Xtrem USER S MANUAL Settop Cell-Xtrem Rev. March 2014 USER S MANUAL 2 Index USER S MANUAL... 1 Settop Cell-Xtrem... 3 Become familiar with the Settop Cell-Xtrem... 4 Become familiar with the Settop Cell-Xtrem

More information

8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010. Quick Installation Guide

8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010. Quick Installation Guide 8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010 Quick Installation Guide Table Of Contents Chapter 1 Introduction... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Technical Specifications... 4 Chapter

More information

VIVA 4G LTE Mini Router. Quick Start Guide

VIVA 4G LTE Mini Router. Quick Start Guide VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product

More information

Projetex 9 Workstation Setup Quick Start Guide 2012 Advanced International Translations

Projetex 9 Workstation Setup Quick Start Guide 2012 Advanced International Translations Projetex 9 Workstation Setup Quick Start Guide 1 Projetex 9 Help Table of Contents Disclaimer 2 System Requirements 2 Registration/Upgrade 3 Projetex Workstation Setup 5 User Login to Projetex Workstation

More information

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective: AG041410 SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective: Determine how to configure the RD500 and your PSTN or GSM modem APPLICATION

More information

EDGE FX Network configuration

EDGE FX Network configuration Page 1 of 16 TITLE: Category: EDGE FX Network configuration GERBER EDGE Document Number: 4280 Supplied by: Gerber Service Last Modified: April 14, 2011 Summary: In order to connect an EDGE FX to your PC

More information

802.11n Wireless Broadband Router WNRT-625

802.11n Wireless Broadband Router WNRT-625 802.11n Wireless Broadband Router WNRT-625 Quick Installation Guide Table of Contents Introduction... 3 Package Content... 4 Hardware Installation... 5 Web Configuration... 8 Further Configuration...11

More information

DIRECT INTERNET DATA. User s Guide

DIRECT INTERNET DATA. User s Guide DIRECT INTERNET DATA User s Guide Iridium Satellite LLC Rev. 2; June 15, 2001 DIRECT INTERNET DATA ------------------------------------------------------------------------------------- TABLE OF CONTENTS

More information

C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial

C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial C-more Remote Access, Data Log, FTP File Transfer, and Email Tutorial P a g e 2 Introduction: This script will walk you through the basic process of setting up the remote access, data logging, FTP file

More information

Quick Installation Guide. Live! Titanium

Quick Installation Guide. Live! Titanium Quick Installation Guide Live! Titanium Contents 1. Live! overview... 2. Installation... 3. Network setup... 4. Wireless setup... 5. Configuring your Live!... 6. Troubleshooting... 2 4 7 8 9 10 1 1. Live!

More information

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: http://192.168.1.1. Password: 1234

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: http://192.168.1.1. Password: 1234 P-3202H-Bb G-PON VoIP IAD Firmware v1.0 Edition 1, 09/2009 DEFAULT LOGIN DETAILS IP Address: http://192.168.1.1 User Name admin Password: 1234 Copyright 2009 Device Panels POWER PON ETHERNET 1~4 PHONE

More information

SIM808 V2.2.5 user manual V1.2. Electrodragon.com

SIM808 V2.2.5 user manual V1.2. Electrodragon.com SIM808 V2.2.5 user manual V1.2 Electrodragon.com time Descriptions version 2015/7/6 initial V1.2 Getting Started A little preparation goes a long way, so make sure you ve covered the following points:

More information

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

This document is intended to make you familiar with the ServersCheck Monitoring Appliance ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other

More information

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual

More information

DATA PROJECTOR XJ-A147/XJ-A247/XJ-A257 XJ-M146/XJ-M156 XJ-M246/XJ-M256. XJ-A Series. XJ-M Series. Network Function Guide

DATA PROJECTOR XJ-A147/XJ-A247/XJ-A257 XJ-M146/XJ-M156 XJ-M246/XJ-M256. XJ-A Series. XJ-M Series. Network Function Guide DATA PROJECTOR EN XJ-A Series XJ-A147/XJ-A247/XJ-A257 XJ-M Series XJ-M146/XJ-M156 XJ-M246/XJ-M256 Network Function Guide In this manual, XJ-A Series and XJ-M Series refer only to the specific models listed

More information

Poseidon2 3268 MANUAL

Poseidon2 3268 MANUAL Poseidon2 3268 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied

More information

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide BiPAC 7404V series VoIP/(802.11g) ADSL2+ (VPN) Firewall Router Quick Start Guide VoIP/(802.11g) ADSL2+ (VPN) Firewall Router For more detailed instructions on configuring and using the Billion VoIP/(802.11g)

More information

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied. AG082411 Objective: How to set up a 3G connection using Static and Dynamic IP addressing Equipment: SITRANS RD500 Multitech rcell MTCBAH4EN2 modem PC with Ethernet card Internet explorer 6.0 or higher

More information

Point of View ProTab 3XXL IPS - Android 4.0 Tablet PC. Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents...

Point of View ProTab 3XXL IPS - Android 4.0 Tablet PC. Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... Point of View ProTab 3XXL IPS - Android 4.0 Tablet PC English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1.0 Product basics... 3 1.1 Buttons and connections...

More information

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1 Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...

More information

BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE

BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE 12/11/2012 Index 1 INTRODUCTION... 1-1 2 FACTORY DEFAULT SETTINGS... 2-1 3 CPE BASIC OPERATIONS... 3-1 3.1 PASSWORD MODIFICATION...

More information

Software for Agilent Technologies Vector Series Network Analyzers

Software for Agilent Technologies Vector Series Network Analyzers Using the Software Software for Agilent Technologies Vector Series Network Analyzers Software Overview The IntuiLink Vector Series Network Analyzer (VNA) software offers a set of connectivity tools that

More information

P-870HN-51b. 802.11n VDSL2 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.00 Edition 1, 9/2009. IP Address: http://192.168.1.1.

P-870HN-51b. 802.11n VDSL2 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.00 Edition 1, 9/2009. IP Address: http://192.168.1.1. P-870HN-51b 802.11n VDSL2 4-port Gateway Firmware v1.00 Edition 1, 9/2009 DEFAULT LOGIN DETAILS IP Address: http://192.168.1.1 Username: admin Password: 1234 www.zyxel.com Copyright 2009 ZyXEL Communications

More information

GV-Data Capture V3 Series User's Manual

GV-Data Capture V3 Series User's Manual GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights

More information

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia E70 Configuring connection settings Nokia E70 Configuring connection settings Legal Notice Copyright Nokia 2006. All

More information