KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS-020000, identification se table of results.



Similar documents
How to Test a Combi Control Unit

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

Info 15:2 TRAINING 2015/2016. Info 13:19

ISO and SANAS guidelines for use of reference materials and PT scheme participation Shadrack Phophi

Case study Realistic and best uncertainties with humidity instruments

The Radon Calibration Laboratory at the Federal Office for Radiation Protection (BfS)

EffiValidation 3.0 software basic training module

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

European cooperation for EAL-G23 THE EXPRESSION OF UNCERTAINTY IN QUANTITATIVE TESTING. The Expression of Uncertainty in Quantitative Testing

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES

Calibration Certificate

CALIBRATION OF A THERMISTOR THERMOMETER (version = fall 2001)

Experiences with novel developed secondary conductivity sensors within the German Calibration Service (DKD)

Temperature Calibration; Depths of Immersion

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS

Microbiological Laboratory Quality Assurance

EQUIPMENT CALIBRATION/MAINTENANCE

Calibration method for conductivity cells

EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa

Hand-held thermometer Model CTH7000

Quality Management System Policy Manual

Gravimetric determination of pipette errors


How To Test A Titrette And Digital Burette

Core Fittings C-Core and CD-Core Fittings

Check-list for auditors. Audit visit at candidate registered laboratories

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

To purchase a full bound copy of this document contact

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

Experience with taximeters with a look at the corresponding tables

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

General and statistical principles for certification of RM ISO Guide 35 and Guide 34

Measuring equipment in a laboratory.

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

American Association for Laboratory Accreditation

EXPRESSION DE L INCERTITUDE DANS LE CAS D ESSAIS QUANTITATIFS

ISO/IEC ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES

Test equipment for temperature and its reduction

Wireless Data Logger Monitoring Systems

Certificate of Calibration No

Calibration of Electronic Test Equipment: An Introduction to ISO & Accreditation

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Procedure for Equipment Calibration and Maintenance

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1

Figure 1. A typical Laboratory Thermometer graduated in C.

Measuring instruments in industry.

we prove it. Designed to Meet Your Expectations Service Offer ELPRO Off-Site Service - Check-up - Repair - Calibration - Replacement

Maintenance in instrumentation Maintenance with concept and technology focusing on results

Laboratory Exercise: Calibration of a Thermometer

R&S ZCxxx Millimeter-Wave Converters Specifications

Guidelines on the Calibration of Static Torque Measuring Devices

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

Definition of classes and info material to manufacturers related to EN ISO 9806

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås

How to calibrate an RTD or Platinum Resistance Thermometer (PRT)

b a n e d we t S bol y a S

Conductivity Sensor Calibrations to Meet Water Industry Requirements

CALIBRATION DATA MANAGEMENT: MEETING THE REPORTING REQUIREMENTS OF ISO/IEC FDIS

Of all the physical properties, it is temperature, which is being measured most often.

INTERNATIONAL STANDARD

ISO17025 INTERPRETATION DOCUMENT FOR CEC TEST METHODS

How To Determine Uncertainty In A Source Stream

(Uncertainty) 2. How uncertain is your uncertainty budget?

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

THERMAL INSULATION MATERIALS

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Metrology and Calibration of Mechatronic Systems. Metrology and Calibration of Mechatronic Systems overview ( ) Adrian M.

Procedure for Procurement and Receipt

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

American Association for Laboratory Accreditation

CALIBRATION PRINCIPLES

RUSKA PRODUCTS - PRICE LIST

Uncertainty of Force Measurements

3M CORPORATE METROLOGY SERVICES St. Paul, MN

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

NIST Standard Reference Materials: Supporting Metrology and Traceability for the Forensic Science Community

CMMs and PROFICIENCY TESTING

Developments in Low Temperature Testing of Rubber Materials

Guidelines on the Reporting of Compliance with Specification

PROCEDURE FOR FRESH APPLE AND PEAR EXPORTS FROM SOUTH AFRICA TO MEXICO. Responsibility: Service Manager: Special Shipments Name: Initial:

Quality Assurance (QA) & Quality Control (QC)

Experiment 6 ~ Joule Heating of a Resistor

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Infrared Thermometer Calibration A Complete Guide

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

utfärdat av riksmätplats 01 issued by a Swedish National Laboratory Contact person Lars-Erik Josefson 2014-03-27 1 (3) MTv4F006969-K01 Measurement Technology +46 10 516 54 56 larserik.josefson@sp.se EcoGuard AB Hammarbacken 4A 191 49 SOLLENTUNA Calibration of temperature logger Identification Object 25 temperature loggers Ecoguard model TS-020000, identification se table of results. Object state Upon arrival the objects had no visual damages. Calibration location The National Laboratory for Temperature, SP, Borås, Sweden Calibration date March 25, 2014 Measurement methods and procedures Comparison in liquid baths with one of the resistance thermometers of SP according to SP- Method 2876. The loggers were protected from contact with the fluid of the bath during the calibration. The temperature loggers registered the temperature in the bath for at least 4 hours at each temperature. The measurement results are presented in the form of mean values in the table. A central Unit CE-015110 and web interface Sensor Reading Report Generator was used for reading the loggers. The temperature loggers were not adjusted before the calibration. According to data from the customer are the calibrated temperature loggers manufactured in year 2014, week 10. Also according to customer the loggers are collected randomly from production without any kind of selection Measurement conditions Temperature scale Results ITS-90 Results and expanded uncertainty of the calibration are presented in the form of a table on page 2. Postal address Office location Phone / Fax / E-mail National Laboratories are designated by the Swedish Government SP Box 857 SE-501 15 BORÅS Sweden Västeråsen Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se according to the Act (2011:791) and the Decree (2011:811) concerning testing and metrology. SP operates under ISO 17025, supervised by SWEDAC. This document may not be reproduced other than in full, except with the prior written approval of SP.

2014-03-27 2 (3) MTv4F006969-K01 Table of results EcoGuard model TS-020000 Serial no. Correction Correction Correction Expanded at 16 C at 21 C at 26 C Uncertainty C C C C 131670 0.1 0.1 0.1 ±0.15 131675 0.1 0.1 0.0 ±0.15 131676 0.1 0.0 0.0 ±0.15 131881 0.1 0.0 0.1 ±0.15 131882 0.1 0.1 0.1 ±0.15 131883 0.1 0.0 0.0 ±0.15 131884 0.1 0.0 0.1 ±0.15 131885 0.1 0.0 0.0 ±0.15 131886 0.0 0.0 0.0 ±0.15 131887 0.1 0.0 0.1 ±0.15 131888 0.0 0.0 0.0 ±0.15 131889 0.1 0.1 0.0 ±0.15 131902 0.1 0.1 0.1 ±0.15 131904 0.0 0.0 0.0 ±0.15 131906 0.1 0.0 0.0 ±0.15 131907 0.0 0.0 0.0 ±0.15 131909 0.1 0.0 0.0 ±0.15 131971 0.1 0.1 0.1 ±0.15 131975 0.1 0.1 0.1 ±0.15 131976 0.1 0.0 0.0 ±0.15 131977 0.1 0.1 0.0 ±0.15 131978 0.1 0.1 0.0 ±0.15 131979 0.1 0.1 0.0 ±0.15 131980 0.1 0.1 0.1 ±0.15 131988 0.0 0.1 0.0 ±0.15 True temperature = instrument reading + correction Uncertainty The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for a normal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty has been determined in accordance with EA Publication EA-4/02 (formerly EAL-R2). The long term stability of the calibrated object is not included in the reported expanded uncertainty of measurement.

2014-03-27 3 (3) MTv4F006969-K01 Traceability The measurement results are by regular calibrations of the laboratory s standards traceable to the Swedish National Laboratories for electrical quantities and temperature at SP in Borås. The National Laboratory for Temperature realizes ITS-90 from -189.3442 C to 2600 C. To ensure international equivalence and acceptance of the established traceability, interlaboratory comparisons are made between national laboratories. Equipment Resistance thermometer, Pt100 ohm, serial no. 68254 DTM, Hart 1502A, serial no. A13412 Water bath, Heto KB 24, serial no. 7612 Measurement Technology - Volume, Flow and Temperature Performed by Examined by Signature_1 Lars-Erik Josefson Signature_2 Magnus Holmsten

utfärdat av riksmätplats 01 issued by a Swedish National Laboratory Contact person Lars-Erik Josefson 2014-03-27 1 (3) MTv4F006969-K02 Measurement Technology +46 10 516 54 56 larserik.josefson@sp.se EcoGuard AB Hammarbacken 4A 191 49 SOLLENTUNA Calibration of temperature logger Identification Object 22 temperature loggers Ecoguard model TS-020000, identification se table of results. Object state Upon arrival the objects had no visual damages. Calibration location The National Laboratory for Temperature, SP, Borås, Sweden Calibration date March 25, 2014 Measurement methods and procedures Comparison in liquid baths with one of the resistance thermometers of SP according to SP- Method 2876. The loggers were protected from contact with the fluid of the bath during the calibration. The temperature loggers registered the temperature in the bath for at least 4 hours at each temperature. The measurement results are presented in the form of mean values in the table. A central Unit CE-015110 and web interface Sensor Reading Report Generator was used for reading the loggers. The temperature loggers were not adjusted before the calibration. According to data from the customer are the calibrated temperature loggers manufactured between 2008 and 2010. Also according to customer all the loggers have been mounted and used in different apartments. Measurement conditions Temperature scale Results ITS-90 Results and expanded uncertainty of the calibration are presented in the form of a table on page 2. Postal address Office location Phone / Fax / E-mail National Laboratories are designated by the Swedish Government SP Box 857 SE-501 15 BORÅS Sweden Västeråsen Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se according to the Act (2011:791) and the Decree (2011:811) concerning testing and metrology. SP operates under ISO 17025, supervised by SWEDAC. This document may not be reproduced other than in full, except with the prior written approval of SP.

2014-03-27 2 (3) MTv4F006969-K02 Table of results EcoGuard model TS-020000 Serial no. Correction Expanded at 21 C Uncertainty C C 6461 0.1 ±0.15 7634 0.0 ±0.15 7930 0.0 ±0.15 8002 0.0 ±0.15 8017 0.0 ±0.15 8064 0.0 ±0.15 8347 0.0 ±0.15 8464 0.1 ±0.15 8530 0.1 ±0.15 8547 0.0 ±0.15 13599 0.0 ±0.15 13640 0.1 ±0.15 13662 0.0 ±0.15 13759 0.1 ±0.15 14642 0.0 ±0.15 15898 0.0 ±0.15 16035 0.0 ±0.15 17844 0.0 ±0.15 18006-0.1 ±0.15 18626 0.0 ±0.15 34792 0.1 ±0.15 110576 0.1 ±0.15 True temperature = instrument reading + correction Uncertainty The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for a normal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty has been determined in accordance with EA Publication EA-4/02 (formerly EAL-R2). The long term stability of the calibrated object is not included in the reported expanded uncertainty of measurement.

2014-03-27 3 (3) MTv4F006969-K02 Traceability The measurement results are by regular calibrations of the laboratory s standards traceable to the Swedish National Laboratories for electrical quantities and temperature at SP in Borås. The National Laboratory for Temperature realizes ITS-90 from -189.3442 C to 2600 C. To ensure international equivalence and acceptance of the established traceability, interlaboratory comparisons are made between national laboratories. Equipment Resistance thermometer, Pt100 ohm, serial no. 68254 DTM, Hart 1502A, serial no. A13412 Water bath, Heto KB 24, serial no. 7612 Measurement Technology - Volume, Flow and Temperature Performed by Examined by Signature_1 Lars-Erik Josefson Signature_2 Magnus Holmsten