Reference Design. conference rooms



Similar documents
C-Bus Solutions. Complete commercial control. Make the most of your energy SM

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

MechoNet TM Network Interface (MNI) Specification Submittal

The Consumer Electronics Association TechHome Rating System Guidelines

Lighting Management solutions

High Bay Occupancy Sensor Selection Guide

Commercial Solutions

How To Use A Lutron Power Supply

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

A1.5 Classroom Standards

Climate Ready Control Systems Technical Specifications

Controller board and power supply for vivimat III systems

SECTION LOW VOLTAGE LIGHTING CONTROLS

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

SECTION DETECTION AND ALARM

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

Temperature Control from Lutron

overview DyNet over RS485

HDCATS-100. Installation Guide

The Fully Integrated Home

INSTALLATION INSTRUCTIONS

How To Set Up A Minipatch System For A Small Office Or Home Use

LIGHTING CONTROL SYSTEM

Color Mark Sensor with Red or Green LED E3S-VS

Electronic Control Devices The European Product Catalogue 2007

8 Channel Status Input Panel model SIP-8

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

User manual Rev 1.3 Contents

Matrix Fitness 7xi Setup and Network Connection guide

Passion for Innovation

Niko Home Control. Installation Manual

Blue Conference Room

Middleborough Police Electronic Security Narrative

WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Special software can be created for you specific requirements: Lutron Light system, Conson Light System and more

Application/Connection Examples

APPLICATION GUIDE MINI PRODUCT GUIDE

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! RadioRA2 Inclusive Software v5.0.8 or newer

Remote Monitoring and REC 501 Control Unit Product Guide

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

HomeWorks QS Processor

HERZ-Thermal Actuators

EVOline Multimedia Modules

ICANN Remote Participation Hub Technical Documentation

BACnet Automation Interface Module (Network Version)

Electronic Control Devices The European Product Catalogue 2007

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Smart home solutions

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

Passion for KNX innovation

NYC Department of Education Building Condition Assessment Survey P.S. 64 (OLD 71) - MANHATTAN, 600 EAST 6 STREET, MANHATTAN, NY, 10009

One Room One Cable Architectural Specification

Appendix 3H A/V and Video Conferencing Standard

CEDIA Electronic Lifestyles Awards Program Home Technology Professional Categories Technical Criteria for Judging

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Contact Center CC-165 INSTALLATION & USER'S GUIDE

VOIP-500 Series Phone Quick Installation Guide

GRX-PWM Pulse Width Modulation Interface

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

GOVERNMENT HEALTHCARE RETAIL

Local supplier shall be ISO 9001 & OHSAS Certified Company.

Examples of installations

Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart

SMART SENSOR COLLECTION

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Broadway 3D Security System

Trinchero Family Estates Building: Operation User s Guide

Optimize your simple machines... Modicon M218 Selection Guide

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

Future proof lighting management

FX07 Field Controller

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Production analogue video fed to Granicus encoder currently place Phase 3 will provide digital audio video to Granicus encoder

Waveguide Access Point WGA631. Product Guide

Introduction. Page 2 / 9

Imagine, a sound system that fills every room with crystal clear music & offers unequalled performance, flexibility & simplicity.

T7560A,B,C Digital Wall Module

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

HMI display Installation Guide

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

A smart home is a brilliant idea

Climate Ready Shade Operating Systems for residential applications.

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG SL) HPX-1200BL, Black Anodized (FG BL)

TrueAlarm Fire Alarm Systems

Product Specifications Dialog System

A/V and Video Conference Standards for Teaching and Learning Rooms.

Understand VLANs, Wired LANs, and Wireless LANs

ZIPAMINI. Smart Home Controller. make your home smart. Control your home from anywhere in the world

Inverter / Charger Installation General Operations and AC and DC Connections

FX07 Field Controller

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

QSE-CI-NWK-E Control Interface

Transcription:

Reference Design conference rooms

Tomaro Design Group conference rooms The modern commercial conference room embraces communication and multi-media technology from projectors and video conferencing, to automated shades and screens and even interactive whiteboards. In addition, the conference room may be the only room guests or customers are exposed to within the company. For these reasons the lighting and control systems in these spaces need to be well designed and intuitively controlled. Lighting scenes need to be pre-configured but adjustable so multiple users can easily change the settings for their particular meetings. The system should be powerful enough to control all the electronics in the space with just the press of a button on a touchscreen. The right system should take the complexity of the conference room and control it using only a few well configured scenes.

APPLICATION DESCRIPTION SPACE USE ACTIVITIES DIMENSIONS CEILING HEIGHT WINDOWS LIGHTING LIGHTING APPS Conference Room 20 x 30 10 Along One Side of Room Direct and Indirect Fluorescent, Cans, Cove, 0-10V and Forward Phase Dimming Full On, Presentation Mode, Daylighting CONTROL NEEDS & SOLUTIONS LIGHTING INTERFACE SENSORS AUDIO/VIDEO SHADES INFRASTRUCTURE Dimming, presentation mode, daylighting, occupancy sensor. (n.1) Equinox 40 control station at entry, single load control and lighting scenes. (n.2) Light sensor for daylighting, occupancy sensor for energy management. (n.3) Tie in for controlling projection screen (low-voltage relay), IRX II for control of projector and audio/video switching. (n.4) Low Voltage Relay or RS-485 for shade control. (n.5) InFusion Controller in a surface mounted enclosure or a DIN controller. Remote located LVOS Station for 0-10 control or Power Boosters/ScenePoints for forward phase control with an LVOS station and an Equinox station, the entire system can be wired via Cat6/ Ethernet. (n.6)

<SERIALNUM.> CONFERENCE ROOM FLOOR PLAN 2 1 4 3 MOTORIZED SCREEN 6 PROJECTOR 5 MOTORIZED SHADES

Crowne Plaza Hotel DESIGN CONSIDERATIONS The Vantage System allows for complete control over the conference room environment. Preset scenes for presentations and meetings can incorporate the control of lighting, motorized shades, motorized screens, projectors and A/V systems, sensors and temperature. With the press of one button on the Vantage Equinox 40 keypad, you can lower the shades, dim the lights, drop the screen and power up the projector in preparation for a presentation or meeting. Occupancy sensors allow for energy savings as lights can turn off and comfort settings can be set back based on the room being empty. Light sensors can help control and maintain the level of light in the room to take full advantage of natural light during meetings.

IR1 IR2 IR3 IR4 STATUS/ON ETHERNET PORT 1 PORT 2 <SERIALNUM.> LVRS8-DIN 1 2 3 4 5 6 7 8 MAX RATINGS 1AMP 48VAC 30VDC RE RE RE STATION BUS CLASS 2 LOW VOLTAGE RELAY STATION 8 - DIN OPEN ENERGY MANAGEMENT EQUIPMENT 51XT RE RE RE RE RE SERIAL NUMBER STATUS WIRING DIAGRAM AUDIO/VIDEO RACK ELECTRICAL ROOM WIRE LEGEND Unswitched Power Switched Power Station Bus Ethernet Speaker Wire Balanced A/V Misc. (as labeled) CONFERENCE ROOM USER SOURCE USER SOURCE USER SOURCE USER SOURCE ETHERNET TO PREMISES LAN LIGHTING LOADS SENSORS ETHERNET TO PREMISES LAN Each InFusion Controller to have separate dedicated circuit breaker Main feed to circuit breaker panels furnished and installed by electrical contractor 1 2 3 4 5 6 7 8 All lighting circuits shall be fed by 20A line feeds and load wires shall be wired with 12AWG wire SHADES / PROJECTION SCREEN

BILL OF MATERIALS CATEGORY PART NUMBER DESCRIPTION QTY Enclosures ISME-24 InFusion Surface Mount Enclosure 24V 1 Controller IC-24-1 InFusion Controller - 24V Station Bus 1 Load Control LVOS-0-10-PWM Low-voltage 1-10 PWM Station (with Enclosure) 1 Sensors EM-LIGHTSENSOR Ambient Light Level Sensor 1 FL-MS-MINI-360-16 PIR Motion Sensor - 16 ft Radius 1 VDA-0015 Auxiliary Pigtail Cable Assemblies Each 1 Equinox Control Stations EQUINOX40 Equinox 40 Control Station 1 Integration/Misc LVRS8-DIN Low-voltage Relay Station 8 - DIN 1 Distributed Audio/Integration 850D-DA 12x8 Digital Distributed Audio Amplifier 1 IRX II Infrared Emitter Station with RS32 1

INSTALLATION NOTES Install the InFusion Controller remote from the conference room in a temperature conditioned electrical closet. Vantage two conductor station bus cabling is run from the controller to keypads and thermostats. Topology is completely open but total bus length limitations and maximum distance limitations exist (2000 maximum per bus, 1000 maximum distance). Occupancy sensors wire either to low-voltage keypads or Equinox 40s via 22AWG cable, with a minimum of three conductors. Thermostats are located remotely with local flush wall-mount temperature sensor (maximum run 160 ft, 18AWG 2C). A variety of window shade motor control options exist. Whether line voltage or lowvoltage, direct drive or serial port controlled, the hardware to affect the solution will vary accordingly. Vantage 850D-DA and IRX II connected to Premises LAN via Cat6, on the same network as the InFusion Controller. IRX II is used for control of audio sources (provided by integrator) such as satellite radio, ipod docks, music library devices, tuners, CD players. Speaker placement and zones to be specified by the integrator based on the requirements of the management. An Ethernet port to the InFusion Controller allows for centralized and remote system access as well as enabling interface apps on fixed location and portable devices. LVOS Station for lighting can be remotely located with the InFusion Controller, or centrally located in a ceiling or crawl space in the conference room. LVOS station connected to Vantage controller via 16/2 station bus, or Cat6. Alternatively, Power Boosters or ScenePoints can be used for lighting load control and are located centrally in the room, or remotely.

1061 South 800 East Orem, Utah 84097 800.555.9891 801.229.2800 801.224.0355 fax The content in Vantage reference designs for conference rooms is intended to provide a starting point for designers anticipating a project including conference rooms with lighting control and integrated automation. The photos included, unless labeled, are not exact project replicas but are representative of this type of project. www.vantagecontrols.com 2013 by Vantage. All Rights Reserved. Part# 1000000 Rev_A DM/DC 6/13