BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date



Similar documents
Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Declaration of Conformity.

Declaration of Conformity.

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Test Report #: Date: April 8, 2005

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

Electromagnetic Compatibility Test Report Test results of Floww equipment

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

EMC Test for Compliance with EU EMC Directive 2004/108/EU

RAPPORTO DI PROVA / TEST REPORT

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

Telephone- and leased line modem for industrial applications TD-36

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Application Note AN001

Energy Management Energy Meter Type EM23 DIN

Report No R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Waveguide Access Point WGA631. Product Guide

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Rules for Classification and Construction Additional Rules and Guidelines

TEST REPORT FROM RFI GLOBAL SERVICES LTD

RX-AM4SF Receiver. Pin-out. Connections

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Design and Certification of ASH Radio Systems for Japan

15 Series - Electronic step relay and dimmer. Features SERIE

Rack mounted telephone- and leased line modem for industrial applications

30 In Compliance October

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

STRATO LED Drivers 70W, Single output

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Dual Chamber Temporary External Pacemaker

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

EMC Expert System for Architecture Design

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Declaration of Conformity.

ETSI EN V2.1.1 ( ) Harmonized European Standard (Telecommunications series)

Cond-IS RF Conducted Immunity System

The EMI-Receiver according to CISPR

Report No R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010

EMC-conform development of a Tablet-PC

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

IEC and CISPR Standards

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Draft ETSI EN V1.2.1 ( )

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

WIRELESS MAGNETIC CONTACT

Agilent E5100A Network Analyzer

Report No R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

Analysis of Immunity by RF Wireless Communication Signals

R&S ZNC Vector Network Analyzer Specifications

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Fibre Optic Solutions for your Test and Instrumentation needs

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

T200, PTP/IEEE 1588 Grandmaster Clock and

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

FM Radio Transmitter & Receiver Modules

Espotel Test Laboratory Services. November 20, 2014

DATA SHEET DVI - HDCP Extension Cable

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Transcription:

Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT SYSTEM Product Model No. BioStation Mifare OC(BSM-OC) Manufacturer Suprema Inc. Serial No. NONE Country of origin KOREA Other Testing Location Test Result Standard Receipt Date 21-Feb-08 Receipt Number Issued Date 18-Mar-08 Tested Date ESTECH. Co., Ltd 58-1, Osan-Ri, GaNam-Myon, YeoJoo-Gun, KyungKi-Do, Korea 97-1, Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea ETSI EN 301 489-1 V1.6.1(09/2005) ETSI EN 301 489-3 V1.4.1(08/2002) EN 55022:2006 Class B EN 50130-4:1995 + A1:1998 +A2:2003 EN 61000-3-2:2006 EN 61000-3-3:1995+A1:2001 PASS EMC Standard ESTC-08-00314 2008-2-24 ~ 2008-3-5 Tested by J.H.Kim / Senior Engineer (Signature) Approved by * Note J.M. Yang / Engineering Manager (Signature) ESTECH CO., LTD. Rm. 1015 World Venture Center, 426-5 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea. Tel:82-2-867-3201, Fax:82-2-867-3204 o This is certified that the above mentioned products have been tested for the sample provided by client. o No part of this document may not be duplicated or reproduced by any means without the express written permission of Estech Co., Ltd. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 1 of 60

Contents 1. Laboratory Information --------------------------------------------------------- 2. The Essential Requirements and Summary of Test Results----------------- 3. Reference Standards -------------------------------------------------------------- 4. General EUT Description ------------------------------------------------------- 5. Performance criteria--------------------------------------------------------------- 6. Measurement Condition --------------------------------------------------------- 6.1 General. 6.2 EUT Operation and Performance assessment. 6.3 Cable Connecting 6.4 EUT Configurations 6.5 Test Setup for RF Field immunity 7. Electromagnetic Interference Test -------------------------------------------- 7.1 Radiated Emission test 7.2 Conducted Emission test 7.3 Limits concerning harmonic current test 7.4 Limits Concerning Voltage Fluctuations & Flicker test 8. Electromagnetic Susceptibility Test ------------------------------------------ 8.1 Electrostatic Discharge test 8.2 Radiated Electromagnetic Fields test 8.3 Electrical Fast Transients/Burst test 8.4 Surge test 8.5 Conducted Disturbance test 8.6 Voltage Dips and Interruptions test 8.7 Mains Supply Voltage Varations 3 4 5 6 6 8 12 39 9. EUT Photograph ----------------------------------------------------------------- 58 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 2 of 60

1. Laboratory Information 1.1 Laboratory Information. 1.1.1 Laboratory Name : Estech Co., Ltd. 1.1.2 Location Head Office Rm. 1015, World Venture Center II, 426-5 Gasan-dong Geumcheon-gu, Seoul, 153-803. Korea. EMC Lab(Ichon) 58-1, Osan-Ri, GaNam-Myon, YeoJoo-Gun, KyungKi-Do, Korea EMC Lab(Yanggi) 97-1, Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea 1.1.3 Quality System Accredited by KOLAS(ISO/IEC 17025) 1.1.4 Major Accredited Mark Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 3 of 60

2. The Essential Requirements and Summary of Test Results EN Reference No. Reference EN-Requirements EN 301 489-1 & EN 55022 & EN 50130-4 EN 61000-3-2 & EN 61000-3-3 Fixed Mobile Portable Comments 1 8.2 2 8.3 3 8.4 Radiated Emission DC power Conducted Emission AC mains Conducted Emission Pass NA Pass 4 8.5 Harmonic Current Emission Pass 5 8.6 Voltage Fluctuations and Flicker Pass 6 8.7 Telecommunication Port Pass 7 9.2 8 9.3 9 9.4 10 9.5 11 9.6 12 9.7 RF Field immunity test ESD immunity test Fast Transient and Burst RF common mode DC power Transient and Surge Voltage dips and interruptions Pass Pass Pass Pass NA Pass 13 9.8 Surge immunity Pass NOTE: These EN-Requirements are justified under the R&TTE Directive and EMC Directive Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 4 of 60

3. Reference Standards EN 55022:2006 Class B "Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement". EN 61000-3-2:2006:"Electromagnetic compatibility (EMC) - Part 3-2:Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)" EN 61000-3-3:1995+A1:2001:"Electromagnetic compatibility (EMC) - Part3-3: Limits-Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current below than 16 A per phase and not subject to conditional connection". EN 61000-4-2:1995+A1:1998+A2:2001:"Electromagnetic compatibility (EMC) - Part 4-2:Testing and measurement techniques - Electrostatic discharge immunity test". EN 61000-4-3:2006:"Electromagnetic compatibility (EMC) -Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test". EN 61000-4-4:2004:"Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques- Electrical fast transient/burst immunity test". EN 61000-4-5:2006:"Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test". EN 61000-4-6:1996+A1:2001:"Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields". EN 61000-4-11:2004:"Electromagnetic compatibility (EMC) - Part4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests". Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 5 of 60

4. General EUT Description 4.1 Summary of Equipment Under Test EUT Name Model Number Serial Number Manufacturer Country of origin : FINGERPRINT SYSTEM : BioStation Mifare OC(BSM-OC) : NONE : Suprema Inc. : Korea Power Rating : AC input100 ~240 VAC,1.0A, 50/60Hz : DC output 12V---2.5A 4.1.1 RF specification Frequency Range (KHz) Modulation Operating channel Antenna type 13.56MHz ASK 1CH PCB Pattern Ant. 5. Performance criteria for immunity test 5.1 Classification of SRD equipments Class 1 Class 2 Class 3 Remark : Class 2 SRD is applied to this equipment, as declared by the manufacturer. Referenced by the Annex B. Performance classification of SRDs, this device is classified as class 2 SRD according to the equipment application as Telemetry applications - product identification 5.1.1 Performance criteria CT(Continuous Phenomena for Trasmitter immunity) : Performance criteria A TT(Transient Phonomena for Transmitter immunity) : Performance criteria B CR(Continuous phenomena for Receiver immunity) : Performance criteria A TR(Transient Phonomena for Receiver immunity) : Performance criteria B Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 6 of 60

5.1.2 Performance table Class 1 SRD Equipment Applcable Criteria During Test After Test Not Applcable A Operate as intended No loss of function For equipment type II the minimum performance shall be 12dB SINAD No unintentional responses Operate as intended For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions B May show loss of function (one or more) No unintentional responses Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions Class 2 SRD Equipment Applcable Criteria During Test After Test Not Applcable A B Operate as intended No loss of function For equipment type II the minimum performance shall be 6dB SINAD No unintentional responses May show loss of function (one or more) No unintentional responses Operate as intended For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions Class 3 SRD Equipment Applcable Criteria During Test After Test A and B May show loss of function (one or more) No unintentional responses Not Applcable Operate as intended, for equipment type II the communication link may be lost, but shall be recoverable by user Lost function(s) shall be self-recoverable No degradation of performance Lost functions shall be self-recoverable Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 7 of 60

6. Measurement Condition 6.1 General Equipment Type Type 1 : Transfer of messages (digital or analogue signals) Type 2 : Transfer of audio (speech or music) Type 3 : Others EUT antenna condition : The antenna is permanently incorporated in the PCB and test has been performed with the antenna fitted in a manner typical of normal intended use. 6.2 EUT Operation and Performance assessment The EUT was in the following operation mode during all testing - Continuous RF output was transmitted when the power supply is on-state. Performance Assessment for Immunity test for Wireless 1. Connect EUT to NOTE PC and Test Board 2. Checked spectrum of 13.56MHz frequency with spectrum analyzer Performance Assessment for Immunity test for Alarm device 1. Connect fingerprint system to Note PC,Local Lan and relay board. 2. Put hand to pingerprint system and check action availability from Note PC. 3. Check fingerprint system under continuous sending and receiving packet data between external network. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 8 of 60

6.3 Cable Connecting Test mode:wireless Start Equipment End Equipment Cable Name I/O port Name I/O port Length Shielded Remark FINGERPRINT SYSTEM Power Adapter - 2.0 UnShielded Test mode:alarm device portion Start Equipment End Equipment Cable Remark Name I/O port Name I/O port Length Shielded FINGERPRINT SYSTEM USB Notebook Computer USB 2.0 Shielded FINGERPRINT SYSTEM LAN External Network LAN 20.0 UnShielded FINGERPRINT SYSTEM LINE INTERCOM LINE 3.0 Shielded FINGERPRINT SYSTEM RS232 Notebook Computer RS232 2.0 Shielded FINGERPRINT SYSTEM LINE (RS485,Wiegand) - - 3.0 Shielded FINGERPRINT SYSTEM Power Adapter - 2.0 UnShielded Notebook Computer Power Adapter - 2.0 UnShielded Intercom Power Adapter - 0.5 UnShielded Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 9 of 60

6.4 EUT Configurations Test mode:alarm device portion Remark Equipment Name Model Name S/N Manufacturer (CE ID) FINGERPRINT SYSTEM BioStation Mifare OC(BSM-OC) NONE Suprema Inc. E.U.T Notebook Computer D400 NONE Dell Asia Pacific Sdn. INTERCOM TP-nAc NONE COMMAX RS232 to RS485 TCC-80 azwhc1900053 Moxa Technologies Co.,Ltd. Adapter PW127 KA1202N57 AULT KOREA CORP. Adapter JPW128 NONE AULT KOREA CORP. Adapter DA-1650-05D NONE Equipment Name Model Name S/N Lite-ON ELECTRONICS INC. Test mode:wireless Manufacturer Remark (CE ID) FINGERPRINT SYSTEM BioStation Mifare OC(BSM-OC) NONE Suprema Inc. E.U.T Adapter JPW128 NONE AULT KOREA CORP. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 10 of 60

6.5 Test Setup for RF Field immunity Test Setup:Alarm device portion Test Setup:Wireless mode Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 11 of 60

7. Electromagnetic Interference Test 7.1 Measurement of radiated emission In the range of 30 MHz to 1 GHz the Electric Field strength was measured in accordance with EN 301 489-1 & EN 301 489-3. This standard for emission requirements applies to electrical and electronic apparatus intended for use in the residential, commercial and light-industrial environment. The test setup was made according to EN 55022:2006 Class B on an open test site, which allows a 10 m distance measurement. The height of this table was 0.8m. The measurement was conducted with both horizontal and vertical antenna polarization. The turntable has fully rotated. For further description of the configuration refer to the picture of the test set-up. 7.1.1 Measurement equipments Equipment Name Receiver Spectrum Analyzer Amplifier 2070-01 8447F Manufacturer Rohde & Schwarz EMCO Serial No. 838562/002 ADVANTEST 61720116 LogBicon Antenna VULB 9160 S/B 3142 Turn Table Antenna Mast Multi Device Controller Type ESVS10 R3261C 2087 2090 EMCO 2129 9702-203 EMCO 1535 - HP 2805A02972 Next Calibration date 26-Jan-09 20-Apr-08 7-May-08 - - 26-Jun-08 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 12 of 60

7.1.2 Environmental conditions Section Temperature ( C) Humidity (%) Radiated Test Place 10 Open site : 10m 35 7.1.3 Test data sheet Test Date : Frequency [MHz] 24-Feb-08 Reading [dbuv] Position [V/H] Height [m] 216.78 8.20 V 1.0 250.00 15.10 H 3.8 283.36 14.70 H 3.2 316.80 14.20 H 3.0 750.76 4.80 V 1.0 Correction Factor Antenna [db/m] Cable etc. [db] 21.88 5.85 Test mode:wireless Limit 44.05 6.90 H 4.0 12.09 0.38 30.0 19.37 10.63 50.43 8.50 V 1.0 12.51 0.71 30.0 Result Value [dbuv/m] Result 53.98 12.00 V 1.0 12.16 0.78 30.0 24.94 112.54 10.50 V 1.0 10.49 1.33 30.0 22.31 7.69 10.25 2.27 30.0 20.72 225.02 12.00 H 4.0 10.57 2.35 30.0 24.92 5.08 11.52 2.50 37.0 29.12 12.58 2.83 37.0 30.11 13.49 3.08 37.0 30.77 Margin [db] 21.72 8.28 5.06 9.28 7.88 6.89 6.23 37.0 32.53 4.47 Remark *Result Value=Reading+Correction Factor *Correction Factor=Antenna factor+cable loss Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 13 of 60

Test Date : Frequency [MHz] 1-Mar-08 Reading [dbuv] Position [V/H] Height [m] Correction Factor Antenna [db/m] Cable etc. [db] Test mode:alarm device portion Result Value [dbuv/m] Limit Result Margin [db] 44.03 6.70 H 4.0 12.09 0.38 30.0 19.17 10.83 50.42 8.20 V 1.0 12.51 0.71 30.0 21.42 8.58 54.00 11.90 V 1.0 12.15 0.78 30.0 24.83 5.17 66.00 10.70 H 4.0 10.54 0.90 30.0 22.14 7.86 73.72 12.40 H 4.0 9.16 0.83 30.0 22.39 7.61 112.54 10.50 V 1.0 10.49 1.33 30.0 22.31 7.69 137.66 9.40 H 4.0 12.55 1.48 30.0 23.42 6.58 200.02 10.10 V 1.0 9.61 2.20 30.0 21.91 8.09 216.71 9.50 V 1.0 10.25 2.27 30.0 22.02 7.98 225.02 11.90 H 4.0 10.57 2.35 30.0 24.82 5.18 244.13 10.20 H 3.2 11.30 2.56 37.0 24.05 12.95 250.01 16.90 H 3.8 11.52 2.50 37.0 30.92 6.08 283.36 18.00 H 3.2 12.58 2.83 37.0 33.41 3.59 316.69 15.70 H 3.0 416.67 9.10 H 2.6 466.69 7.80 H 2.4 550.07 6.30 V 1.0 13.48 3.08 37.0 32.27 4.73 15.77 3.78 37.0 28.65 8.35 16.85 4.10 37.0 28.75 8.25 18.30 4.75 37.0 29.36 7.64 600.00 4.30 H 2.0 19.69 5.00 37.0 28.99 8.01 750.76 5.00 V 1.0 21.88 5.85 37.0 32.73 4.27 Remark *Result Value=Reading+Correction Factor *Correction Factor=Antenna factor+cable loss Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 14 of 60

Setup for Radiated Test : 30 ~ 1000 MHz [ Front ] Test mode:wireless [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 15 of 60

Setup for Radiated Test : 30 ~ 1000 MHz [ Front ] Test mode:alarm device portion [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 16 of 60

7.2 Conducted emission test The continuous disturbance voltage of AC Mains in the frequency from 0.15 to 30 MHz was measured in accordance to EN 301 489-1 & EN 301 489-3. The test setup was made according to EN 2006 Class B in a shielded Room. The EUT was placed on a non-conductive table at least 80 above the ground plane. A grounded vertical reference plane was positioned in a distance of 40cm from the EUT. The distance from the EUT to other metal surfaces was at least 0.8m. The EUT was only earthen by its power cord through the line impedance stabilizing network. The power cord has been bundled to a length of 1.0m. The test receiver with Quasi peak detector. Setup Mothodfor Telecom port Conducted common mode (asymmetric mode) disturbance at telecommunication ports Measurements were made on a ground plane that extends 1-meter minimum beyond all sides of the system under test. All power was connected to the system through Artificial Mains Network (AMN). All tested telecommunications lines were connected to an Impedance Stabilization Network (ISN) and conducted voltage measurements on telecommunications lines were made at the output of the ISN. Where an ISN was not appropriate or available measurements were made using a Capacitive Voltage Probe and Current probe. The test setup was made in accordance with EN55022:2006 7.2.1 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date LISN NNLA 8120A Schwarzbeck 8120161 2009-2-29 LISN ESH3-Z5 Schwarzbeck 838979/010 2009-2-29 TEST Receiver ESPI7 Rohde & Schwarz 100185 27-Aug-08 Pulse Limiter ESH3Z2 Rohde & Schwarz NONE - LCL Adapter AD T444 SCHAFFNER 18881.01 N/A Connecting Adapter AD T444R SCHAFFNER 18881.03 N/A Impedance Stabilization Network ISN T400 Schwarzbeck 16846 18-Sep-08 7.2.2 Environmental conditions Section Temperature ( C) Humidity (%) Conducted Test Place 19 36 Shield Room Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 17 of 60

7.2.3 Test data sheet Test Date : Frequency (MHz) 24-Feb-08 Test mode:wireless Correction Factor Quasi-peak Value Average Value (db) Line (dbuv) (dbuv) (H/N) LISN Cable etc. Limit Reading Result Limit Reading Result 0.19 0.16 0.10 N 63.9 34.02 34.23 53.9 0.20 0.18 0.10 H 63.5 44.21 44.45 53.5 0.27 0.13 0.10 N 51.2 41.44 41.65 51.2 0.33 0.12 0.10 N 59.4 40.78 40.97 49.4 0.34 0.20 0.10 H 59.3 40.68 40.94 49.3 0.40 0.14 0.10 N 57.8 42.21 42.44 47.8 0.54 0.15 0.10 N 56.0 34.56 34.80 46.0 0.61 0.15 0.10 N 56.0 39.88 40.13 46.0 0.37 0.16 0.10 N 56.0 30.79 31.04 46.0 0.74 0.16 0.10 N 56.0 29.62 29.88 46.0 1.21 0.26 0.20 N 56.0 26.08 26.53 46.0 1.47 0.20 0.20 H 56.0 24.81 25.24 46.0 6.76 0.41 0.60 H 60.0 26.30 27.29 50.0 8.63 0.45 0.60 H 60.0 27.52 28.61 50.0 8.64 0.56 0.60 N 60.0 26.97 28.18 50.0 10.37 0.66 0.80 N 60.0 30.92 32.34 50.0 10.57 0.50 0.80 H 60.0 30.16 31.43 50.0 25.00 0.93 1.30 H 60.0 29.17 31.40 50.0 25.21 25.42 30.38 30.62 31.68 31.89 32.30 32.49 31.54 31.80 33.82 34.05 27.03 27.27 31.66 31.91 23.79 24.04 23.18 23.44 20.18 20.63 19.07 19.50 18.82 19.81 20.17 21.26 19.05 20.26 20.62 22.04 16.68 17.95 29.01 31.24 Remark H : Hot Line, N : Neutral Line *Result Value=Reading+Correction Factor *Correction Factor=LISN factor+cable loss *According to 4.3.2 Clause,ETSI EN301 489-3,the exclusion band is three times the maximum occupied bandwith allowed for that service,centred around the operating frequecy(13.56mhz). Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 18 of 60

Test Date : Frequency (MHz) 1-Mar-08 Correction Factor (db) Line (H/N) LISN Cable etc. Test mode:alarm device portion Quasi-peak Value Average Value (dbuv) (dbuv) Limit Reading Result Limit Reading Result 0.19 0.15 0.79 H 63.9 37.73 38.67 53.9 35.09 36.03 0.20 0.17 0.79 N 63.6 43.88 44.84 53.6 36.08 37.04 0.26 0.20 0.85 N 61.3 38.19 39.23 51.3 33.86 0.33 0.21 0.86 N 59.4 37.33 38.40 49.4 26.16 0.40 0.13 0.83 H 57.9 33.32 34.28 47.9 28.15 0.46 0.20 0.80 N 56.6 32.89 33.89 46.6 30.00 0.60 0.20 0.79 N 56.0 34.63 35.62 46.0 34.75 2.11 0.23 0.84 N 56.0 31.75 32.83 46.0 39.08 2.12 0.31 0.84 H 56.0 31.45 32.61 46.0 32.04 2.23 0.32 0.85 H 56.0 34.72 35.89 46.0 33.37 2.97 0.34 0.88 H 56.0 30.97 32.19 46.0 35.03 34.90 27.23 29.11 31.00 35.74 40.16 33.20 34.54 36.25 3.83 0.36 0.91 H 56.0 30.90 32.18 46.0 7.80 0.49 1.17 N 60.0 39.92 41.57 50.0 35.73 40.46 37.01 42.11 8.66 0.49 1.25 N 60.0 41.24 42.98 50.0 39.47 41.21 8.72 0.55 1.26 H 60.0 40.74 42.55 50.0 40.16 41.97 9.39 0.50 1.32 N 60.0 40.24 42.06 50.0 38.06 39.88 9.51 0.62 1.33 H 60.0 41.38 43.34 50.0 51.67 53.63 10.44 0.52 1.37 N 60.0 41.19 43.08 50.0 44.03 45.92 Remark H : Hot Line, N : Neutral Line *Result Value=Reading+Correction Factor *Correction Factor=LISN factor+cable loss Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 19 of 60

dbµv 1 PK CLRWR 2 AV CLRWR 7.2.4 Spectral Diagram Hot Line 90 80 70 EN55022Q 60 EN55022A 50 Att 10 db AUTO RBW 9 khz MT 1 s PREAMP OFF 1 MHz 10 MHz LIMIT CHECK PASS Test mode:wireless SGL TDF PRN 40 6DB 30 20 10 0 150 khz 30 MHz Comment: BSM-OC_HOT Date: 24.FEB.2008 23:21:31 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 20 of 60

dbµv 90 NEUTRAL Line Att 10 db AUTO RBW 9 khz MT 1 s PREAMP OFF 1 MHz 10 MHz LIMIT CHECK PASS 1 PK CLRWR 2 AV CLRWR 80 70 EN55022Q 60 EN55022A 50 SGL TDF PRN 40 6DB 30 20 10 0 150 khz 30 MHz Comment: BSM-OC_NEUTRAL Date: 24.FEB.2008 23:15:00 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 21 of 60

Hot Line Test mode:alarm device portion dbµv 90 Att 10 db AUTO RBW 9 khz MT 1 s PREAMP OFF 1 MHz 10 MHz LIMIT CHECK PASS 1 PK CLRWR 2 AV CLRWR 80 70 EN55022Q 60 EN55022A 50 SGL TDF PRN 40 6DB 30 20 10 0 150 khz 30 MHz Comment: BioStation BSM-OC_HOT Date: 1.MAR.2008 06:06:18 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 22 of 60

dbµv 90 NEUTRAL Line Att 10 db AUTO RBW 9 khz MT 1 s PREAMP OFF 1 MHz 10 MHz LIMIT CHECK PASS 1 PK CLRWR 2 AV CLRWR 80 70 EN55022Q 60 EN55022A 50 SGL TDF PRN 40 6DB 30 20 10 0 150 khz 30 MHz Comment: BioStation BSM-OC_NEUTRAL Date: 1.MAR.2008 06:01:26 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 23 of 60

Setup for Conducted Test : 0.15 ~ 30 MHz [ Front ] Test mode:wireless [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 24 of 60

Setup for Conducted Test : 0.15 ~ 30 MHz [ Front ] Test mode:alarm device portion [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 25 of 60

7.2.5 Test data sheet (Telecommunication Port ) Test Date 1-Mar-08 Frequency (MHz) Correction Factor (db) Line (H/N) LISN Cable etc. Quasi-peak Value (dbuv) Limit Reading Result Limit Average Value (dbuv) Reading Result 0.20 9.25 0.79-81.6 49.59 59.63 71.6 31.80 41.84 0.33 9.31 0.86-77.4 46.43 56.60 67.4 37.22 47.39 0.40 9.37 0.83-75.9 46.92 57.12 65.9 0.67 9.82 0.80-74.0 47.22 57.84 64.0 1.42 9.64 0.81-74.0 48.48 58.93 64.0 1.43 9.64 0.81-74.0 51.58 62.03 64.0 4.28 9.96 0.93-74.0 53.73 64.62 64.0 7.14 9.96 1.10-74.0 53.12 64.18 64.0 39.88 50.08 39.96 50.58 44.85 55.30 50.88 61.33 47.01 57.91 46.28 57.34 Remark *Result Value=Reading+Correction Factor *Correction Factor=LISN factor+cable loss Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 26 of 60

7.2.6 Spectral Diagram dbµv 110 Att 10 db AUTO RBW 9 khz MT 1 s PREAMP OFF 1 MHz 10 MHz 1 PK CLRWR 2 AV CLRWR 100 90 COM22Q-B 80 COM22A-B 70 SGL TDF 60 PRN 50 6DB 40 30 20 10 0 150 khz 30 MHz Comment: Biostation_BSM-OC_TEL Date: 1.MAR.2008 18:33:45 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 27 of 60

7.3 Limits concerning harmonic current test The harmonics on AC Mains in the frequency from 0 to 2 khz were measured in accordance to EN 61000-3-2:2006 The objective of this standard is to set limits for harmonic emissions of equipment within its scope, so that, with due allowance for the emissions from other equipment, compliance with the limits ensures that harmonic disturbance do not exceed the compatibility levels defined in IEC 61000-3-2. For the purpose of harmonic current limitation, equipment is classified as follows. Class A : - Balanced three-phase equipment; - Household appliances excluding equipment identified as Class D; - Tools excluding portable tools; - Dimmers for incandescent lamps; - Audio equipment. Equipment not specified in one of the three other classes shall be considered as Class A equipment. Class B : - Portable tools; - Arc welding equipment which is not professional equipment. Class C : - Lighting equipment. Class D : Equipment having a specified power less than or equal to 600 W, of the following types: - Personal computers and personal computer monitors; - Television receivers. 7.3.1 Measurement equipments Equipment Name Type Manufacturer Serial No. Test System PHF555 HAEFELY 08419-11 Next Calibration date 7-Dec-08 Upgrade test system PHF X HAEFELY 151336-7.3.2 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 20 35 101.7 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 28 of 60

Setup Figure Test mode:wireless N/A Test mode:alarm device portion N/A Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 29 of 60

7.3.3 Test data sheet Test Date : 27-Feb-08 Test mode:wireless *It does not need to test this requirement, because the input power of the EUT is supplied from Note PC Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 30 of 60

Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 31 of 60

Test Date : 4-Mar-08 Test mode:alarm device portion *It does not need to test this requirement, because the input power of the EUT is supplied from Note PC Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 32 of 60

Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 33 of 60

7.4 Limits Concerning Voltage Fluctuations & Flicker test The voltage fluctuations on AC mains in the frequency range from 0 to 2 khz were measured in accordance to EN 61000-3-3:1995 +A1:2001 7.4.1 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date Test System PHF555 HAEFELY 08419-11 7-Dec-08 Upgrade test system PHF X HAEFELY 151336 7.4.2 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 21 37 101.7 - Setup Figure Test mode:wireless N/A Test mode:alarm device portion N/A Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 34 of 60

7.4.3 Test data sheet Test Date : 27-Feb-08 Test mode:wireless *It does not need to test this requirement, because the input power of the EUT is supplied from Note PC Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 35 of 60

Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 36 of 60

Test Date : 5-Mar-08 Test mode:alarm device portion *It does not need to test this requirement, because the input power of the EUT is supplied from Note PC Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 37 of 60

Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 38 of 60

8. Electromagnetic Susceptibility Test 8.1 Electrostatic Discharge test 8.1.1 Test Standard - Standard :EN 61000-4-2:1995 +A1:1998 +A2:2001 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria for wireless : TT/TR (Criterion B) - Performance criteria for alarm device : Criterion B - Energy storage capacitance : 150pF (±10%) - Discharge resistance : 330 ohm (±10%) - Charging resistance : 50 Mohm (50 ~100Mohm) - Tolerance of the output voltage indication : ± 5% - Polarity of the output voltage : Positive(+) and Negative(-) - Holding time : at least 5s - Discharge, Mode of operation : Single discharge - Interval discharge time : At least 1s - Repetition time : At least 200 discharges. 100 each at negative and positive polarity of four test points (a minimum of 50 discharges of each point) At least 50 indirect discharge(contact) to the center of the front edge of the horizontal coupling plane At least 200 indirect discharges shall be applied in the indirect mode use of the vertical conducting plane. 8.1.2 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date ESD Simulater NSG438 Schaffner 601 23-Jun-08 8.1.3 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 20 38 101.8 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 39 of 60

8.1.4 Test data Test Date : 1-Mar-08 Test mode:wireless Point Test Method Test Voltage (+/-) Criterion Result Remark HCP Horzontal Coupling 2 Air discharge 3 Air discharge 2,4kV VCP Vertical Coupling 2,4kV B A 1 Air discharge 2,4,8kV B 2,4,8kV 2,4,8kV 4 Air discharge 2,4,8kV B 5 Air discharge 2,4,8kV B 6 Air discharge 2,4,8kV B 7 Air discharge 2,4,8kV 8 Air discharge 2,4,8kV B 9 Air discharge 2,4,8kV B B B B B A A A A A A A A A A Remark VCP Vertical Coupling 2,4,6kV Test mode:alarm device portion Point Test Method Test Voltage (+/-) Result Remark HCP Normal operation Normal operation 1 Air discharge 2,4,8kV Normal operation 2 Air discharge 2,4,8kV 3 Horizontal Coupling Air discharge 2,4,6kV 2,4,8kV Normal operation Normal operation 4 Air discharge 2,4,8kV Normal operation 5 Air discharge 2,4,8kV Normal operation 6 Air discharge 2,4,8kV Normal operation 7 Air discharge 2,4,8kV Normal operation 8 Air discharge 2,4,8kV Normal operation 9 Air discharge 2,4,8kV Normal operation Remark Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 40 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 41 of 60

Test Point 1 2 3 4 5 6 7 8 9 1 The LCD left top part of the front side 2 The front button part 3 The USB port part 4 The LCD right bottom part of the front side 5 The finger scanner part of the front side 6 The top button part 7 The center cover part of the rear side 8 The center cover part of the left side 9 The center cover part of the right side HCP: Indirect Discharge VCP : Indirect Discharge Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 42 of 60

8.2 Radiated Electromagnetic Fields test 8.2.1 Test Standard - Standard :EN 61000-4-3:2006 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria for wireless : CT/CR (Criterion A) - Performance criteria for alarm device : Criterion A - Frequency Range for alarm device: 80 MHz ~ 2000MHz - Frequency Range for wireless : 80 MHz ~ 1000MHz, 1.4GHz ~ 2.0 GHz - Test Angle : 0, 90, 180, 270 - Sweep Capability : 1.5 10-3 decade/s - Step Size : 1% of Fundamental - Antenna Polarity : Horizontally/Vertically - Measurement Distance : 3m - Modulation : AM 80% with 1kHz sine wave, Pulse 1Hz (0.5s On: 0.5s OFF) - Dwell time : 3 seconds - Field Strength:(1,3,10)V/m 8.2.2 Measurement equipments Equipment Name Hybrid Log Periodic Antenna Type LPDA-0803 Manufacturer TDK Serial No. Next Calibration date 130243 N/A Amplifier 250W1000AM1 Amplifier Research 311841 4-Jun-08 Amplifier 60S1G3M1 Amplifier Research 311684 4-Jun-08 Signal Genertor 8648C HP 3623A03549 11-Jun-08 Power Sensor URV5-Z2 Rohde&Schwarz 100592 19-Oct-08 Power Meter NRVD Rohde&Schwarz DE25524 19-Oct-08 System Interface SI-300-2 TDK 41610 NONE Arbitray Waveform Generator 33220A Agilent MY44009149 15-Jun-08 8.2.3 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 19 36 102 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 43 of 60

8.2.4 Test data Test Date : 1 3 10 Reference 1-Mar-08 Range of Frequency (MHz) 80 MHz ~ 1 GHz 1.4 GHz ~ 2 GHz Reference Electromagnetic Intensity (V/m) Position Front side Right side Left side Rear side Position Front side Right side Left side Rear side Top side Bottom side Front side Right side Left side Rear side Top side Bottom side Front side Right side Left side Rear side Top side Bottom side Polarity Polarity H V H V H V H V H V H V H V H V H V H V H V H V H v H V H V H V H V H V H : Horizontality, V : Verticality *Frequecy range:80mhz to 2GHz Electromagnetic Intensity (V/m) AM Mod. Test mode:wireless H 3 A A V 3 A A H 3 A A V 3 A A H 3 A A V 3 A A H 3 A A V 3 A A H : Horizontality, V : Verticality Test mode:alarm device portion Result Criterion Normal operation Normal operation Normal operation Pulse Mod. Result Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 44 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 45 of 60

8.3 Electrical Fast Transients/Burst test 8.3.1 Test Standard - Standard :EN 61000-4-4:2004 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria for wireless : TT/TR (Criterion B) - Performance criteria for alarm device : Criterion B - Test voltage : a.c. mains supply lines : ±0.5,1,2kV, other supply/signal lines : 0.25,0.5,1kV - Polarity : Positive(+), Negative(-) - Repetition Frequency : 5kHz - Duration Time : 60s 8.3.2 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date Burst Generator BEST EMC V2.7 SCHAFFNER 200220-006SC 22-May-08 Coupling Clamp IP4A Haefely 153419 N/A Decoupling Clamp F-2031-32MM-DCN FCC 343-8.3.3 Environmental Conditions Temperature ( C) 20 Humidity (%) 35 Pressure (kpa) 101.9 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 46 of 60

8.3.4 Test data Test Date : 3-Mar-08 Test mode:wireless Tested Point Test Voltage Duration Time (s) Criterion Result Remark L1 ±1kV 60s B A Input AC L2 ±1kV 60s B A L1 to L2 ±1kV 60s B A Reference Tested Point Test Voltage L1: Line, L2: Neutral, PE: Protective earth (Ground) Duration Time (s) Test mode:alarm device portion Result Remark L1 ±0.5,1,2kV 60s Normal operation Input AC L2 ±0.5,1,2kV 60s Normal operation L1 to L2 ±0.5,1,2kV 60s Normal operation I/O Port LAN ±0.25,0.5,1kV 60s Line(Intercom) ±0.25,0.5,1kV 60s Normal operation Normal operation Reference L1: Line, L2: Neutral, PE: Protective earth (Ground) Test after extend signal cable to 3m length. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 47 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 48 of 60

8.4 Surge Test 8.4.1 Test Standard - Standard :2006 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria for wireless : TT/TR (Criterion B) - Performance criteria for alarm device : Criterion B - Test voltage AC : line-earth : ±2kV, line-line : ±1kV, Telecom. & signal : Line-earth : ±1kV, DC port :±0.5kV - Test voltage : a.c. mains supply lines - line-to-line: ±0.5,1kV -line-to-ground:±0.5,1,2kv other supply/signal lines -line-to-ground:±0.5,1 - Polarity : Positive(+), Negative(-) - Repetition rate:max 1/min. - Number of tests:at least five positive and five negative at the selected points. - Phase shifting:in a range between 0 to 360 versus the a.c. line phase angle. 8.4.2 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date Surge Generator BEST EMC V2.7 SHAFFNER 200220-006SC 22-May-08 8.4.3 Environmental Conditions 8.4.4 Test data Temperature ( C) 21 Humidity (%) 34 Pressure (kpa) 101.8 Test Date : 3-Mar-08 Tested Point Test Voltage Test mode:wireless Criterion Result Remark Input AC L1 to L2 ±1kV B A Reference L1: Line, L2: Neutral, PE: Protective earth (Ground) Note1 : Test angle-0, 90, 180, 270 Note2 : The ac adapter used for testing is class II type without GND connection. The surge application to Line - GND was not performed. Tested Point Test Voltage Result Test mode:alarm device portion Remark Input AC L1 to L2 ±0.5,1kV Normal operation Reference L1: Line, L2: Neutral, PE: Protective earth (Ground) Note1 : Test angle-0, 90, 180, 270 Note2 : The ac adapter used for testing is class II type without GND connection. The surge application to Line - GND was not performed. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 49 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 50 of 60

8.5 Conducted Disturbance test 8.5.1 Test Standard - Standard :EN 61000-4-6:1996+A1:2001 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria for wireless : CT/CR (Criterion A) - Performance criteria for alarm device : Criterion A - Frequency Range for wireless : 0.15~80 MHz - Frequency Range for alarm device: 0.15~100MHz - Modulation : AM 80% with 1kHz sine wave, Pulse 1Hz (0.5s On: 0.5s OFF) - Dwell time : 3 seconds - Sweep Capability : 1.5 10-3 decade/s - Step Size : 1% of Fundamental - Field Strength:1V,3V,10V 8.5.2 Measurement equipments Equipment Name Type Manufacturer Amplifier 75A250AM1 Amplifier Research Serial No. Next Calibration date 312197 4-Jun-08 Signal Generator 8648C HP 3623A03549 11-Jul-08 Power Sensor URV5-Z2 R&S 100592 19-Oct-08 Power Meter NRVD R&S DE25524 19-Oct-08 ATTENUATOR 50FH-006-300-2 Amplifier Research NONE - Arbitray Waveform Generator 33220A Agilent MY4400914 15-Jun-08 CDN FCC-801-M2-16A FCC 5028 2-Jul-08 CDN FCC-801-T4 FCC 9955 6-Apr-08 EM CLAMP EM101 EM TEST AG 35806 - Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 51 of 60

8.5.3 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 18 36 101.9 8.5.4 Test data Test Date : 3-Mar-08 Test mode:wireless Freq [MHz] Level [V] Tested point Criterion Result Remark 0.15~80 3 Mains A A Reference Test mode:alarm device portion Tested point Level [V] AM Mod. Result Pulse Mod. Remark Mains LAN Port EM CLAMP(Intercom, RS-485) 1 Normal operation 3 Normal operation 10 Normal operation(b) 1 Normal operation 3 Normal operation 10 Normal operation(b) 1 Normal operation 3 Normal operation 10 Normal operation(b) Note:1 Note:1 Note:1 Reference Test after extend signal cable to 3m length Frequency range:0.15 to 100MHz Note 1:Regarding the compliance criteria, the following acceptance criteria has been considered. The acceptance criteria for normal function is that there is no change in the functioning of equipment and no significant change key function measures within the manufacturer specification. In 10Vrms conditioning, the beep sound occurrence was permissible because the there was no residual change in the EUT and any change in output to associated equipment connected. Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 52 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 53 of 60

8.6 Voltage Dips and Interruptions test 8.6.1 Test Standard - EN 61000-4-11:2004 & EN 50130-4:1995 + A1:1998 +A2:2003 - Performance criteria : A special condition set out in the EN 301 489-3 Clause 7.2.2 30% 10ms : CT (Criteria A) 60% 100ms : TT (Criteria B for Class 2 and 3) >95% 5000ms : TT (Criteria B) - Number of pulses : 3 at each level - Recovery time between interval : 10 seconds - Test angle : Zero crossings - Additional angles : 45,90,135, 180,225,270,315 - We tested both lower voltage ( 100V ) and higher voltage ( 240V ). - Performance appraisal standard and test level for alarm device 30% - 0.5, 1, 5, 10 cycles,60% - 0.5, 1, 5, 10 cycles, 100% - 0.5, 1, 5 cycles 8.6.2 Measurement equipments Equipment Name Type Manufacturer Serial No. Next Calibration date Dip Generator BEST EMC V2.7 SCHAFFNER 200220-006SC Test System PHF555 HAEFELY 08419-11 Upgrade test system PHF X HAEFELY 151336 22-May-08 7-Dec-08-8.6.3 Environmental Conditions Temperature ( C) Humidity (%) 20 34 Pressure (kpa) 102 Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 54 of 60

8.6.4 Test data Test Date : 3-Mar-08 Test mode:wireless Test level Duration Period of the rated frequency Required Criterion Result Remark 30% 10ms A A 60% 100ms B A >95% 5000ms B B Reference Note1:During the Interruptions (95%.5000ms) a power of EUT was loss of communicable function for Lan port. But the EUT was returned to normal when the interference was removed. Test mode:alarm device portion Test level Duration Cycles Result Remark 30% 60% 100% Reference 0.5 Normal operation 1 Normal operation 5 Normal operation 10 Normal operation 0.5 Normal operation 1 Normal operation 5 Normal operation 10 Normal operation 0.5 Normal operation 1 Normal operation 5 Normal operation *Tested both voltage 100V and 240V Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 55 of 60

Setup Figure Test mode:wireless Setup Figure Test mode:alarm device portion Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 56 of 60

8.7 Mains Supply Voltage Varations 8.7.1 Measurement equipments Equipment Name Type Manufacturer Serial No. Simulator BEST EMC V2.7 SCHAFFNER 200220-006SC Next Calibration date 22-May-08 8.7.2 Environmental Conditions Temperature ( C) Humidity (%) Pressure (kpa) 8.7.3 Test data 20 34 102 Test Date : 3-Mar-08 Supply Voltage Max %UT Unom(V) Supply Voltage Result Umax 253 Unom+10% Normal operation Umin 195.5 Unom-15% Normal operation Reference Measurememt condition : For temperature stability conditioning, The manufacturer's specification was applied instead of measuring the time lapse. Warm up condition to normal operation is 10 min. The measurement has been made time until time lapse up to 10 min. Setup Figure Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 57 of 60

9. EUT Photographs [ Front ] EUT A [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 58 of 60

[ Front ] EUT B [ Rear ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 59 of 60

[ Inside ] Report Number : ESTCE0803-003 Web : www. estech. co. kr Page 60 of 60