Revised: Previously Issued As: P/BC 2011-095 PLUMBING FIXTURES



Similar documents
PLUMBING FIXTURES GUIDELINES

BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION

CHAPTER 29 PLUMBING SYSTEMS

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

How To Calculate Fixture Counts For A Building

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR No. 110

City of Riverside Building & Safety Division Phone: (951)

Chapter 3: Use and Occupancy Classification

Chapter PLUMBING CODE

(1) (a) through (1) (e) (iv) Remain the same.

DRAFT ONLY ORDINANCE NO.

2016 BUILDING PERMIT FEES*

Georgia Smokefree Air Act O.C.G.A A-1 through 31-12A-13

Plumbing Code Sections For Commercial Food Facilities

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION CODE

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

CHAPTER Facilities for types of occupancies not shown on this table will be determined by the Administrative Authority.

VENTILATION CHAPTER 4

Fire Alarm Systems Permit Packet. City of Greer Fire Department

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

New York City Department of Buildings

Rehling and NicholasJ. i3artilucci

ADA Scoping: New Construction

VENTILATION CHAPTER 4

ACCESSIBILITY CHAPTER 11

CONSTRUCTION PERMIT APPLICATION AND INSTRUCTIONS (Permit Application follows instructions)

Water Use Reduction Additional Guidance

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

148 Unit Apartment / YMCA Investment Sale

Requested Increase SF. Current SF

DEEMED-TO-BE-APPROVED (PAD) OR PLAN APPROVAL (PA) CONDITIONAL USE SCHOOLS, CHURCHES, SENIOR HOUSING, ANIMALS

Applicable to Private Establishments. Smoking Rooms Minneapolis, MN

APPLICATION FOR NEW CONSTRUCTION

City Code of ANN ARBOR, MICHIGAN Chapter 55 Zoning

APPLICATION FOR PLAN REVIEW

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

PLUMBING FIXTURES. Current with material published in Conn.L.J. through 6/10/08

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Schedule B to By-law

Schedule B to By-law Part A Fees Payable for Permits

BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC

CHAPTER 4 VENTILATION

2010 ADA Standards for Accessible Design. Department of Justice

University Alcohol Policy

NO: R063. The Planning & Development Department recommends that Council:

SECTION XI OPINION OF PROBABLE COST

FAIRFIELD INN & SUITES GEN 4 Proto-Model Design ARCHITECTURE AND CONSTRUCTION

SQUARE FOOTAGE REQUIREMENTS FOR USE IN DEVELOPING THE LOCAL FACILITIES PLANS AND STATE CAPITAL OUTLAY APPLICATIONS FOR FUNDING

Schneps, Leila; Colmez, Coralie. Math on Trial : How Numbers Get Used and Abused in the Courtroom. New York, NY, USA: Basic Books, p i.

Final - Adopted February 6, 2012 AN ORDINANCE

City of Clayton Event Guidelines

The intent of this chapter in establishing the R-G Residential General District is as follows:

VENTILATION CHAPTER 4

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Guideline for Square Footage Requirements for Educational Facilities (a) 4. Educational Facility Site, Construction, and Reimbursement

Uniform With Exceptions

Pennsylvania Uniform Construction Code Homeowner s Guide

CHAPTER 2: The Plumbing System

2006 IBC BUILDING CODE CHECKLIST FOR COMMERCIAL PROJECTS

Utility Service Application

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

HAMILTON SCHOOL Brentwood Parkway, N.E., Washington, DC INITIAL YEAR BUILT 1968 BUILDING AREA

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

IOWA ADMINISTRATIVE CODE PUBLIC HEALTH [641] CHAPTER 153 SMOKEFREE AIR

HOW TO START A COFFEE SHOP IN PHILADELPHIA

Plumbing Code Statutes and Regulations February 2011 Labor Standards and Safety Division Mechanical Inspection

PATTERSON ELEMENTARY SCHOOL

Meeting Facilities. Building: Alumni Hall Room #: 312 Seating Capacity: 28

NEW YORK. Downloaded Title: Section Nutrition and dining services Nutrition and dining services.

Special Use Commercial Properties

Planning Commission Meeting September 4, 2008

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012

RELOCATION OF BUILDINGS

WHEN IS A PERMIT REQUIRED?

Sec Adoption of Texas Department of Health Standards for Public Swimming Pool and Spa.

CA Title Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

How To Improve A School In Ancient Ginghamshire

New York City Department of Buildings


Spouse #1: Spouse #2: Who is the primary contact, and what is the best time and way to reach that individual?

Fan Applications & System Guide

CFAO SANITARY CONTROL OF INDOOR AND OUTDOOR POOLS AND SWIMMING AREAS

BUSINESS USE PERMIT APPLICATION

INSTALLATION OF WATER-CONSERVING PLUMBING FIXTURES SB 407 California Civil Code Section Green Building Standards Code

3. Tile used in the toilets is generally in good shape, though somewhat dated looking. The floor tile is slippery when wet.

Division S-37. PD Subdistrict 37.

Supplemental Plan Check Corrections Sheet for Bicycle Parking Ordinance (Effective 3/13/2013)

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

CITY OF BAY CITY ORDINANCE NO. 628

The Alameda/Rose Garden Neighborhood

General Lighting Recommendations

PUBLIC BUILDING COMMISSION OF CHICAGO. Alexander Graham Bell Elementary School Addition and Renovation

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Transcription:

INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec. 2901 Effective: 01-01-2014 DOCUMENT NO. P/BC 2014-095 Revised: Previously Issued As: P/BC 2011-095 PLUMBING FIXTURES Section 2901 of the Los Angeles Building Code (LABC) refers to the Los Angeles Plumbing Code (LAPC) to determine the minimum number of the plumbing fixtures required for each type of building occupancies. In accordance to LAPC, the minimum number of plumbing fixtures are shown in Table 422.1, except that Table 4-2 shall be used for medical clinics licensed by the state, as required by LAPC Section 422.0. (See LABC Section 304.2 and 202 for definition of Clinics ). The categories not shown in Table 422.1 of the LAPC are addressed by section VIII of this Information Bulletin. The minimum number of plumbing fixtures are assumed to be based on 50 percent male and 50 percent female users. The occupant load shall be determined using the Table A Occupant Load Factor of Table 422.1 of the LAPC. I. GUIDELINE TO DETERMINE MINIMUM REQUIRED FIXTURES A. New Buildings 1. Determine the occupant load based on the proposed floor area for each occupancy 2. Determine the required number of plumbing fixtures for each occupancy 3. Determine the total number of plumbing fixtures by adding the required number of the plumbing fixtures for each occupancy B. Existing Buildings For the following cases, either options I or II may be used: 1. Change of occupancy classification or change of use for an existing tenant space or building. 2. Addition or alteration that increases the occupant load of the existing buildings may use any of the following options; however, alterations without an increase in occupant load, other than case 1 above, may maintain their existing non-conforming toilet facilities without complying with current plumbing fixture requirements. Option I. a. Calculate the number of occupants within the addition or altered area. b. Determine the required number of fixtures from the applicable table in the plumbing code or this Information Bulletin. Page 1 of 6

c. Provide the required number of fixtures based on item b above within the addition or altered area, or in a common area of the existing building accessible from the addition or altered area per Section II of this Information Bulletin. Option II. a. Calculate the occupant load for the existing building prior to the addition or alteration. b. Determine the required number of fixtures for the existing building from the applicable table in the plumbing code or this Information Bulletin. c. Calculate the occupant load for the existing building with the addition or alteration. d. Determine the required number of fixtures, based on the occupant load from item c above, from the applicable table. e. Subtract the number of fixtures determined from item b from those determined from item d above. The difference will be the number of additional fixtures required, unless the number of the existing fixtures equal or exceed those determined from item d above. In this case no additional fixtures will be required. f. Provide the required number of additional fixtures within the addition or altered area, or in a common area of the existing building accessible from the addition or altered area per Section II of this Information Bulletin. Example for an Addition: An existing 100,000 square feet warehouse with a 20,000 square feet addition. The existing occupant load per Table A is 20 with the addition adding 4 more occupants. There are existing toilet rooms for men and women. The men s room has one water closets, two urinals, and two lavatories. The women s room contains two water closets and one lavatories. Option I. The applicable table is Table 422.1. The addition would require one new water closet and one new lavatory for each gender. Option II. The applicable table is Table 422.1. The existing warehouse building with 20 occupants may be credited with one water closet and one lavatory in each of the men s and women s rooms. For 24 occupants after the addition, a total of two water closets and two lavatories would be required for each gender. By applying the credit, one new water closet but no new lavatory would need to be added to the men s room. Similarly, no new water closet but one new lavatory would need to be added to the women s room. Clearly there is an advantage to use option II for this example. Page 2 of 6

Example for an alteration that increases the occupant load: An existing 100,000 square feet warehouse with an alteration to convert 10,000 square feet into a wholesale accessory use. The existing occupant load per Table A is 20. The new occupant load with the alteration will be the total of 18 for warehouse and 50 for wholesale use. There are existing mens and women s toilet rooms. The men s room has one water closets, two urinals, and two lavatories. The women s room has two water closets and one lavatories. Option I. The applicable table is Table 422.1. The alteration converting 10000 sf to wholesales would create 25 occupants for each gender. This alteration would require one new water closet, no new urinal, and one new lavatory for the men s room. Similarly one new water closet and one new lavatory will be required for the women s room. Option II. The applicable table is Table 422.1. The existing warehouse building with 20 occupants may be credited with one water closet and one lavatory in each of the men s and women s rooms. With the alteration, the men s room(s) would require for wholesales use one water closet and one lavatory, and for warehouse use one water closet and one lavatory. Thus a total of 2 water closet and 2 lavatories are required for the men s room. Similarly a total of 2 water closet and 2 lavatories are required for the women s room. By applying the credit, one new water closet needs to be added to the men s room and the existing water closet must be maintained. Since there are 2 existing lavatories in the men s room, no new lavatory is needed. For the women s room, since there are 2 existing water closets, no new water closet is needed. However, one new lavatory needs to be added to the women s room after applying the credit and the one existing lavatory must be maintained. Clearly there is an advantage to use option II for this example. II. NUMBER OF FIXTURES PER FLOOR Section 422.4.1 of the LAPC requires, in multi-story buildings, the availability of the required plumbing fixtures shall not exceed one vertical story. Fixtures shall be provided on each floor based on the number of occupants on each floor or provided for each group of floors based on the number of occupants for that group of floors. III. FLOORS SERVING CUSTOMERS AND EMPLOYEES Section 422.4 of the LAPC allows a single set of restrooms accessible to both customers and employees for facilities in mercantile and business occupancies. This section will apply to a Page 3 of 6

restaurant which is considered as a business that sells food to be consumed on the premises according to Footnote 2 of Table 422.1 in the LAPC. The required number of fixtures shall be the greater of the required number for employees or the required number for customers. (See footnotes of Table 422.1 in the LAPC for additional requirements) IV LOCATION OF FIXTURES Access to public facilities (for the customer) shall not be through areas designated for employee use only such as kitchens, storage rooms, closets or similar spaces. V. ACCESSIBILITY REQUIREMENTS FOR PERSONS WITH DISABILITIES New Facilities. When new facilities are provided, they must comply with the accessibility requirements. Existing Facilities. When existing facilities are to be used as the required sanitary facilities for an addition or alteration, the existing facilities must comply with disabled access regulations (unreasonable hardship may be granted as applicable per disable access regulations). VI. CONFLICTS BETWEEN CODES Whenever there is a conflict between codes or different provisions of the same code, the most restrictive provision shall be applied. VII. FOOD SERVICE ESTABLISHMENTS A food establishment such as a restaurant with an area of 1500 sf or less may be considered as a business according to Footnote 2 on Table 422.1 in the LAPC, and may provide one toilet facility to be used by no more than one person at a time to serve customers and employees of both sexes per LAPC section 422.2. However, any establishment serving alcoholic beverage or having four or more employees shall provide separate toilet rooms for each sex per LABC Section 6302.4. VIII. TYPES OF BUILDINGS OR OCCUPANCIES NOT SHOWN IN TABLE 422.1 AND TABLE 4-2 Section 422.3 and Table 422.1 of the LAPC allows for building occupancies and categories not shown in the adopted tables to be considered separately as deemed appropriate by the Authority Having Jurisdiction. The following Table VIII-1may be used for such building occupancies or categories: Page 4 of 6

TABLE VIII -1 MINIMUM PLUMBING IN COMMUNITY FACILITY TYPE OF USE OCC. LOAD (per SF unless noted) PLUMBING FIXTURES (unit per person unless noted) WATER CLOSETS 1 MALE FEMALE URINALS LAVATORIES (per water closet) DRINKING FOUNTAIN A. COMMUNITY FACILITY. A facility containing a multi-purpose use of which the primary purpose is to provide non-profit assistance and services to the general Such multi-purpose use shall be related to social services, child care, job assistance, business assistance, educations, adult day care, cultural services, gyms or recreation, community meetings, auditoriums as an incidental service, and administrative offices. The following factors may be used for such a community facility. A1. Gymnasiums and Multipurpose Rooms Gymnasiums and Multipurpose rooms that do not function as an Auditorium 1:30 Stage Only 1:30 1:75 1:40 1:75 1:2 1:75 Storage rooms 1:5000 A2. Indoor or Outdoor Swimming Pool & Associated Bathhouse Pool Area 1:200 Pool Deck 1:30 Cashier / Check Room 1:200 1:75 1:40 1:75 1:2 1:75 Dressing Area 1:200 A3. Child Care Outdoor Play Area 0 0 0 0 0 Classrooms - up to Age 16 1:50 1:75 1:40 1:75 1:2 1:75 Parent/ Guest Waiting Area (Incidental to Main Use) 0 0 0 0 0 A4. Associated Community Room Uses Activity - Craft Rooms 1:30 Billiard or Game Room 1:30 6 Dressing Rooms 1:200 1:75 1:40 1:75 1:2 1:75 Office / Staff Area 1:200 Office for consultation and associated community service functions 1:200 1: 1-100 2: 101-200 3: 201-400 10 3: 1-50 4: 51-100 8: 101-200 11: 201-400 10 1: 1-100 2: 101-200 3: 201-400 4: 401-600 4 1: 1-200 2: 201-400 3: 401-750 2 1:75 Page 5 of 6

TYPE OF USE Dining Area Kitchen Area OCC. LOAD (per SF unless noted) 1:30 PLUMBING FIXTURES (unit per person unless noted) WATER CLOSETS 1 URINALS LAVATORIES (per water MALE FEMALE closet) 1:1-50 2:51-150 3:151-300 7 DRINKING FOUNTAIN 1: 1-50 8 1: 1-150 1:1-150 2: 51-150 2: 151-200 4: 151-300 7 3: 201-400 9 Lobby Accessory to Assembly Occupancy Mechanical Room General Storage and Custodial Room 0 0 0 0 0 Footnotes: 1. The total number of water closets for females shall be at least equal to the total number of water closets and urinals required for males. 2. Over 750 occupants, add one lavatory for each additional 500 persons. 3. Over 400 occupants, add one water closet for each additional 500 males and 1 for each additional 125 females. 4. Over 600 occupants, add 1 Urinal for each additional 300 males. 5. Over 750 occupants, add 1 Drinking Fountain for each additional 500 persons. 6. The occupant load shall be determined by dividing the superficial floor area (the area determined by deducting the area occupied by pool tables from the total floor area) by 15 sq. ft per occupant. 7. Over 300 occupants, add 1 Water Closet for each additional 200 persons. 8. Over 150 occupants, add 1 Urinal for each additional 150 males. 9. Over 400 occupants, add 1 Lavatory for each additional 400 persons. 10. Over 400 occupants, add one water closet for each additional 500 males and 1 for each additional 150 females. IX. Speculative Buildings A minimum of one men s and one women s toilet room shall be provided during the shell and core phase. Additional required fixtures based on the proposed use of the building shall be provided during tenant improvement. Page 6 of 6