Data Center Infrastructure & Managed Services Outline



Similar documents
DATA CENTRE DATA CENTRE MAY 2015

Level I - Public. Technical Portfolio. Revised: July 2015

Datacenter Hosting and Cloud Computing Services

Security Policy JUNE 1, SalesNOW. Security Policy v v

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Powering the Cloud Desktop: OS33 Data Centers

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

Network Router Monitoring & Management Services

Frankfurt Data Centre Overview

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering % uptime

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Server Monitoring & Management Services

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

DATA CENTRE DATA CENTRE

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

Security Whitepaper: ivvy Products

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Data Center Overview Document

CHICAGO S PREMIERE DATA CENTER

Experience Matters...

SWAP EXECUTION FACILITY OPERATIONAL CAPABILITY TECHNOLOGY QUESTIONNAIRE

StratusLIVE for Fundraisers Cloud Operations

Information Technology Security Procedures

data center - why choose a data center facility

DESIGNATED CONTRACT MARKET OPERATIONAL CAPABILITY TECHNOLOGY QUESTIONNAIRE

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

Data Center Presentation

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

OPERATIONAL CAPABILITY TECHNOLOGY QUESTIONNAIRE

The Anatomy of a. High-Availability Rack. November Online Tech, Inc. 220 E. Huron Ann Arbor, MI (734)

Data Center Commissioning: What you need to know

7QUESTIONSYOUNEEDTOASKBEFORE CHOOSINGACOLOCATIONFACILITY FORYOURBUSINESS

Private Clouds & Hosted IT Solutions

colocation vs. managed servers - the difference

Perceptive Software Platform Services

Sovereign. The made to measure data centre

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

Data Center Management

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

out of this world guide to: POWERFUL DEDICATED SERVERS

MEDIAROOM. Products Hosting Infrastructure Documentation. Introduction. Hosting Facility Overview

Oracle Maps Cloud Service Enterprise Hosting and Delivery Policies Effective Date: October 1, 2015 Version 1.0

HealthcareBookings.com Security Set Up

Data Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM

KNOCK ONE OUT OF THE PARK WITH IP PATHWAYS

Data Centre Barrie, Ontario

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

DATA CENTER FIRE PROTECTION

SITECATALYST SECURITY

melbourne//australia data center specifications internet + intellectual property + intelligence tel: fax:

Data Centre Services. JT Rue Des Pres Data Centre Facility Product Description

LDeX Group. Colocation Solutions for High Expectations

PHP/MySQL APPLicAtion HoSting

OPERATOR - FACILITY ADDRESS - DATE

colocation. perfected. Overview

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Powerful Dedicated Servers

NeuStar Ultra Services Physical Security Overview

DATACENTER COLOCATION. Flexible, Secure and Connected

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

North Street Global, LLC. Business Continuity Plan

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS

Data Center Security 100% UPTIME PUZZLE. Page 1

Colocation Hosting Primer Making the Business and IT Case for Colocation

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Seattle London

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

White paper. SAS Solutions OnDemand Hosting Overview

Hosted Testing and Grading

GTS Software Remote Desktop Services

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Secure, Scalable and Reliable Cloud Analytics from FusionOps

colocation. perfected.

GOVERNANCE AND SECURITY BEST PRACTICES FOR PAYMENT PROCESSORS

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Our Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security.

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Server Room, Data Centre Management and Monitoring Solutions

112 Linton House Union Street London SE1 0LH T: F:

SYSTRUST CERTIFICATION REPORT FOR COLLOCATION AND DATA CENTER HOSTING SERVICES FOR THE PERIOD FROM JANUARY 1, 2013 TO DECEMBER 31, 2013

HOST COLOR LLC INFRASTRUCTURE, NETWORK & OPERATIONS

DISASTER RECOVERY. Omniture Disaster Plan. June 2, 2008 Version 2.0

Transcription:

Data Center Infrastructure & Managed Services Outline The 360 Technology Center Solutions Data Center is located in Lombard, IL, USA. We are 20 minutes outside of downtown Chicago. The 360TCS staff consists of a group of handpicked data center professional possessing over 50 years combined experience in data center and managed service solutions. security and reliability. The brief outline below should answer most of your questions regarding any design, provisioning, network redundancy and security issues. In the event of you require any additional information, please feel free to contact our Director of Sales / Account Relations: Don Welbourn 888-313- 1306 dwelbourn@360tcs.com Provisioning & Design Electrical Grid The 360TCS Data Center is powered by two separate Utility (ComEd) feeds with an automated transfer configuration at the Utility level making the loss of primary power an extremely unlikely event. Each of our custom made, 42U, extra wide / extra deep cabinets feature 4 individual power circuits on two separate feeds (A/B). Each circuit can deliver 30A/208V on separate breakers providing full redundancy. All circuits are protected by automated UPS (Uninterruptible Power Supply) and power generator fail- over. UPS & Generator The UPS farm is designed to provide an N+1 redundancy level and has maintenance management switching permitting maintenance on the unit without disruption to the internal power grid. The UPS also has automated fail over sensors to detect variations in power supply from the power source, it will automatically send a signal to the power generator, which will switch on and gradually regulate the power to the circuit. If brownouts occur, the UPS will regulate power itself automatically as well. The UPS was designed to remain active for approximately 18 minutes, assuming the Data Center is occupied at maximum capacity. Currently the UPS has sufficient power to remain active for 30 minutes. It typically takes the power generator less than 16 seconds minutes to become fully active and act as primary power source. This provides a large

margin for the switch over, avoiding any unplanned outages. This process is completely automated. With three battery strings per unit, the UPS comes with redundancy built in. The system undergoes scheduled maintenance and testing including annual testing to ensure operation during actual interruption. Our 2.5MW, Caterpillar 16 cylinder diesel generator is housed in its own enclosure ensuring an optimum environment for operations and nullifying any concerns posed due to its 2500 gallon liquid fuel source. The generator can run continuously for up to 24 hours at full capacity without re- fuelling. The generator undergoes weekly testing, monthly maintenance ensure its continued operation. Multiple suppliers of diesel fuel have been secured in the event that an outage exceeds operational standards and a re- fuelling of the generator is required. HVAC & Environment Control 360TCS maintains a median temperature of 67-72 degrees Fahrenheit in the Data Center irrespective of the occupation level of the cabinets. The cabinet layouts are designed according to a Hot/Cold aisle system raised floor. Our environmentally efficient, closed loop chilled water HVAC system design allows us the ability to effectively cool over 40kW of power consumption per cabinet. The AEAS (Automated Environment Alert System) notifies staff of any temperature variations above 72 degrees. The entire HVAC system has dual components providing redundancy in the event of a failure. The entire system undergoes a monthly maintenance and review cycle to verify optimal operation. Fire Suppression The 360TCS Data Center has redundant fire suppression systems. Our primary system is a Novec 1230 Pre- Engineered Clean Agent Extinguishing System. Novec 1230 Fire Protection Fluid is a colorless, non- toxic fluid. It is stored as a pressurized liquid and injected into the Data Center which has the structural integrity to retain the agent that has been discharged. Novec 1230 Fire Protection Fluid is dispensed as an odorless, electrically non- conductive vapor. It leaves no residue. Novec 1230 Fire Protection Fluid is a clean, efficient fire- extinguishing agent that can be used on types A, B, or C fires. It is a very stable, inert and electrically non- conductive gas. Our secondary system is a zoned, multi- stage, interlocking Pre- Action Fire Suppression System that employs the basic concept of a dry pipe system. Water is held from piping by an electrically operated valve, known as a pre- action valve. Valve operation is controlled by independent flame, heat, or smoke detection. Two separate events must happen to initiate sprinkler discharge. First, the detection system must identify a developing fire and then open the pre- action valve. This allows water to flow into system piping, which effectively creates a wet pipe sprinkler system. Second, individual sprinkler heads must release to permit water flow onto the fire.

Both systems are designed to: 1. Prevent accidental tripping of the system by requiring multiple fire causing inputs. 2. Automate notification of any danger permitting an orderly shutdown of systems prior to initiation of fire suppression preventing permanent system damage. Security & Access Controls Our own on- site security staff patrols the 360TCS Data Center 24x7x365. The facility has 34 closed circuit cameras covering all aisles, entry & exit points, as well as the entire external perimeter. Images are recorded securely and stored for 30 days. Authorized access is available 24x7x365 and is controlled through key card reader in combination with a biometrically controlled fingerprint scan. Standardized Tier System Comparison Chart The Uptime Institute and several other sources maintain a standard description of various levels of Data Center redundancy. Below is a comparison of some of the most commonly used indicators and position within this tiered system Tier 1 Tier 2 Tier 3 Tier 4 360TCS Power 1 1 2 2 2 Delivery Paths Redundant Yes Yes Yes Yes Yes HVAC Raised Floor No Yes Yes Yes Yes UPS + Power Maybe Yes Yes Yes Yes Generator Redundancy N N+1 N+1 2(N) N+1 Electrical / 2N HVAC Concurrently No No Yes Yes Yes Maintainable Infrastructure Site 99.671% 99.749% 99.982% 99.995% 100% Availability Security Maybe Yes Yes Yes Yes Cameras Staffing 1 Shift 1 Shift 1 Shift+ 24/7 24/7

SSAE- 16 360TCS is currently involved in and SSAE 16 Type II audit. The audit process covers a six month period that began in November 2010 and will be complete in May 2011. SSAE 16 replaces the SAS 70 Type II standard, which will no longer be valid starting June 15, 2011. SSAE 16 assures customers that their data is protected by the most current industry standards. Network Design With multiple carrier feeds available, the 360 TCS private fiber ring includes nodes in the Midwest's primary Telco hubs providing a variety of options for reliable connectivity and accessibility. At 360 TCS, we understand the importance of 100% availability alongside low- latency and high bandwidth. As a carrier neutral facility, 360 TCS provides access to multiple providers for connectivity resources. Multi- Path OSPF switches to eliminate single point of failure Redundant switching equipment at every level. Pre- run and tested multi- structured cabling. As carrier neutral facility, Customers who wish to use an independent carrier either as their primary or secondary connection have that option as well. Management Services & Support Services Remote Hands We understand that you are trying to run a business and that you have a lot on your mind. We want you to succeed and as a result are happy to provide complimentary Remote Hands support to help reduce some stress. If you require a reboot or a read- out of your screen messages, we are happy to assist. For more assistance, such as hardware replacement, troubleshooting including patching and other services, please review our Managed Services below. Managed Services 360TCS offers a wide range of managed technology solutions. Our From can provide a custom solution specifically designed to meet our Customer Virtualization Solutions Hosted VMWare Virtual Private Servers Disaster Recovery and Business Continuity

Infrastructure Design and Optimization Network design, specification and requirements for LAN/WAN, routers, switches, hubs, gateways and firewalls Server Infrastructure Optimization Services Software Integration Web hosting Messaging / E- mail Data Integrity and Protection Data Architecture, Analysis and Design Database Administration Backup and Restore Threat Protection and Security Firewall and Intrusion Detection / Prevention Services Anti- Virus Data Backup Critical System Uptime and Monitoring Application Server Monitors Host Services Monitors Microsoft Windows Monitors Database Monitors Network Service Monitors Next Step Choosing a data center and an appropriate managed solution is a complicated procedure requiring the utmost care. 360TCS is ready to assist and we encourage you to communicate with us and ask any questions you may still have about our services including quotations. We hope to create a strong working relationship and wish you much success in your business endeavor. Telephone: 1 888 313 1306 E- mail: sales@360tcs.com Website: www.360tcs.com