1 Modular System Dual SCM MPIO Software Installation



Similar documents
1 MAXDATA Modular System Firmware Update

1 MAXDATA SR1202 Firmware Update

HP ProLiant DL380 G5 High Availability Storage Server

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

Update Firmware from GUI

WhatsUp Gold v16.3 Installation and Configuration Guide

Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server

What Is Ad-Aware Update Server?

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

Bosch Video Management System High availability with VMware

VMware for Bosch VMS. en Software Manual

Microsoft Windows Server 2008* (x86 & x64) Dual SCM (ALUA) Installation BKM. Intel Order Number: E

WhatsUp Gold v16.1 Installation and Configuration Guide

EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager

Polycom HDX Configuration Guide

Moving the TRITON Reporting Databases

Manual OS Installation

Virtual Appliance Setup Guide

QUANTIFY INSTALLATION GUIDE

istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

Reconfiguration of VMware vcenter Update Manager

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

WhatsUp Gold v16.2 Installation and Configuration Guide

RLM Server Guide. For Macintosh and Windows

Installing RMFT on an MS Cluster

Installing and Using the vnios Trial

Migrating MSDE to Microsoft SQL 2008 R2 Express

Chapter 3 Management. Remote Management

Enterprise Manager. Version 6.2. Installation Guide

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

Option Network Management Software for UPS UNMS II

GMS. 1 Create the virtual machine 2 Configure the virtual machine 3 Configure the virtual GMS server. Quick Start Guide. Microsoft Hyper-V Hypervisor

Configuring Sun StorageTek SL500 tape library for Amanda Enterprise backup software

Using Cisco UC320W with Windows Small Business Server

ITA Mail Archive Setup Guide

Also you need the C-MOR ISO file. This file you will find following this link:

Installing SQL Express. For CribMaster 9.2 and Later

Quick Start Guide. GV-Redundant Server GV-Failover Server. 1 Introduction. Packing List

AW-HE60 Firmware Upgrade Procedure

Availability Guide for Deploying SQL Server on VMware vsphere. August 2009

Reconfiguring VMware vsphere Update Manager

Pivotal CRM AvaTax Connector Installation

Administration Guide. . All right reserved. For more information about Specops Gpupdate and other Specops products, visit

DLA Storage Appliance Deployment in NAS/DAS Environment

Setup for Failover Clustering and Microsoft Cluster Service

Xerox Security Bulletin XRX13-006

IBM Security QRadar SIEM Version High Availability Guide IBM

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall

5 Dry Contact Cable User Manual

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

1. Do I need to upgrade my Broadband at Home modem firmware?

HP PolyServe Software upgrade guide

1. How do I access my VPS control panel?

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

CONSOLEWORKS WINDOWS EVENT FORWARDER START-UP GUIDE

Altor Virtual Network Security Analyzer v1.0 Installation Guide

Moving the Web Security Log Database

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Polycom CMA System Upgrade Guide

HP CloudSystem Enterprise

VMware vsphere 5 Quick Start Guide

How To Synchronize the easystore to the AD

IIS, FTP Server and Windows

Chapter 4 Management. Viewing the Activity Log

Specops Command. Installation Guide

SAS 9.3 Foundation for Microsoft Windows

Deploying Windows Streaming Media Servers NLB Cluster and metasan

External Storage 200 Series. User s Manual

P4000 SAN/iQ software upgrade user guide

Bosch Video Management System High Availability with Hyper-V

VCCC Appliance VMware Server Installation Guide

SevOne NMS Download Installation and Implementation Guide

Abila MIP. Installation Guide

Wavecrest Certificate

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

Xopero Backup Build your private cloud backup environment. Getting started

Quick Start - Virtual Server idataagent (VMware)

CommandCenter Secure Gateway

ACTIVE DIRECTORY DEPLOYMENT

1 Axis camera configuration IP configuration Setting up date and time Installing an IPS Analytics Application...

Infinity C Reference Guide

Sophos Anti-Virus for NetApp Storage Systems user guide. Product version: 3.0

GSatTrack. Fleet Broadband Tracker. User Manual April 2011 GSE. Global Satellite Engineering. : gsat.us

Colorfly Tablet Upgrade Guide

DOE VPN Client Installation and Setup Guide March 2011

PowerPanel Business Edition Installation Guide

Printer Performance and Troubleshooting Printers

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

Grandstream Networks, Inc.

3.5 Mobile LAN Disk. User Guide

Clustering VirtualCenter 2.5 Using Microsoft Cluster Services

Quick Start - Virtual Server idataagent (Microsoft/Hyper-V)

QNAP and Failover Technologies

SOA Software API Gateway Appliance 7.1.x Administration Guide

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide

Transcription:

1 Modular System Dual SCM MPIO Software Installation This document will help you to connect a MAXDATA dual controller SAS disk array with redundant dual connection to both storage controller modules (SCM) on the MAXDATA Modular System. A dual connection from the storage to the MAXDATA Modular System will prevent data loss or LUN unavailability, if a controller failure in the storage or the MAXDATA Modular System occurs. Also a failure of a SAS cable would not be have an effect to the LUN availability. With a redundant connection, the Administrator will have enough time to replace or repair the defective components without a system or a storage shutdown. Attention: Backup your data and your OS installation before you start a Firmware upgrade. Data loss or data unavailability during or after an update cannot be excluded. It is not recommended to update firmware or driver on productive systems, because some updates needs a system shutdown. 1.1 Connection The SAS storage controller modules in the Modular System have external SFF-8088 connectors. The external connector of the disk arrays depends on the disk array manufacturer. The MAXDATA RV SAS series have SFF-8088 connectors and the previous MAXFDATA SR1202 disk arrays have SFF- 8470 connectors. So be carefully if you purchase a cable. SFF-8470 SFF-8088 Storage Controller Module (SCM) 1.2 Required Driver / Software on the compute modules (MAXDATA PLATINUM 1000 IM M1) - Storport Patch KB932755 for Windows 2003 - Onboard LSI 1064e SAS controller driver v1.27.3.0 or higher - Storage controller module (SCM) MPIO driver v2.01.0140.16 or higher To download the MPIO and other Modular System driver use ftp://ftp.maxdata.de/maxdata Platinum Server/Drivers u. Utilities/MPL Modular System/ To download the Modular System Firmware use ftp://ftp.maxdata.de/maxdata%20platinum%20server/firmware_bios/mpl%20modular%20 System/ Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 1

1.3 Required Firmware Modular System To use dual controller modules in the MAXDATA Modular System, you have to use the Modular System Firmware Package v2.7 or higher. It is recommended to update the firmware before you install the second SCM and before you install the MPIO driver. You will find more information about MAXDATA Modular System firmware upgrade in the document MAXDATA Modular System Firmware Update. If you use an external SAS storage with dual connection, do not forget to install the storage MPIO driver on all compute modules which have access to the storage LUNs. More information can be found in the documents MAXDATA RV Series MPIO Software Installation or MAXDATA SR1202 MPIO Software Installation. Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 2

1.4 Assigning of external storage LUNs or devices 1. Open a Web browser (eg Firefox or Internet Explorer) and type in the IP address of the Modular Systems. The default IP address is 192.168.150.150 and the default user and password is admin 2. After login click on Switches in the left menu 3. Click on the first controller SCM1 4. On the right side of the window left-click Expansion Port 5. Choose all servers (compute modules) which should have access to the external device. Attention: An external Streamer can have only access from one system and one connection. Abb. 1 6. Left-click Apply to save the configuration 7. Left-click the second controller SCM2 and repeat point 4-6. Attention: If multiple compute modules should have access to different LUNs, you have to configure LUN Masking on the storage or you must use zoning. Otherwise all compute Modules would have access an all LUNs in the storage, which will cause data loss or LUN unavailability on standard Windows installations. Tipp: If you need a shared LUN e.g. for VMware or Microsoft Cluster you can purchase the optional Shared LUN Key article number 400714. The license can be activated with the Link Feature Activation. Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 3

1.5 Microsoft Windows 2003 SCM MPIO driver installation / upgrade 1. Check the dual connection of the volumes in the Windows disk management console. If the volumes are listed twice the dual SCM configuration is working. Attention: Do not use the initialize feature of the disk management console on the same twice listed volumes. Abb. 2 Abb. 3 2. Install Storport Patch KB932755 for Windows 2003. Attention: The language of the storport patch must be equal to your installed Windows language x86: http://www.microsoft.com/downloads/details.aspx?familyid=dead950b-da47-4dc2- ABCD-40F61BD4D1AA&displaylang=en x64: http://www.microsoft.com/downloads/details.aspx?familyid=5ff8c152-9114-458f-86f9-01c2b8cac450&displaylang=en 3. Do not restart system after the storport patch installation 4. Start Windows device manager 5. Expand SCSI- and RAID-Controllers with click on + 6. Right-click the LSI 1064E entry and choose properties 7. Change to the driver tab 8. If the driver version is older than v1.27.3.0, then left-click update driver. (If the driver is v1.27.3.0 or higher restart system to fulfill the storport patch installation requirement) Abb. 4 Abb. 5 Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 4

9. Choose Install from a list or specific location (advanced) and click on next. Next screen choose Include this location in the search and click on Browse. Now choose the path to the LSI driver. Abb. 6 Abb. 7 10. Restart system after the driver installation is completed 11. After restart, start Windows device manager and check if the driver version v1.27.3.0 is installed 12. Start MultiFlex 2.01.0140.16 or higher MPIO driver installation and follow instructions 13. Restart system after the driver installation is completed Abb. 8 Abb. 9 14. After restart, start Windows device manager and check if the MPIO drivers are installed. Abb. 10 Abb. 11 15. Check if the driver version match the version in the release notes Abb. 12 Abb. 13 Abb. 14 Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 5

16. Start the Windows disk management console and check if the volumes are not longer listed twice, otherwise maybe you have to reinstall the MPIO drivers Abb. 15 Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 6

1.6 Microsoft Windows 2008 SCM MPIO driver installation / upgrade 1. Check the dual connection of the volumes in the Windows disk management console. If the volumes are listed twice the dual SCM configuration is working. Attention: Do not use the initialize feature of the disk management console on the same twice listed volumes. Abb. 16 2. Start Windows device manager 3. Expand Storage controllers with click on + 4. Right-click on the LSI 1064E entry and choose properties 5. Change to the driver tab 6. If the driver version is older than v1.27.3.0, then click on update driver. Abb. 17 Abb. 18 7. Choose Browse my Computer for driver software and click on Browse. Now choose the path to the LSI driver. Abb. 19 Abb. 20 8. Restart system after the driver installation is completed 9. After restart, start Windows device manager and check if the driver version v1.27.3.0 or higer is installed Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 7

10. Start MultiFlex 2.01.0140.16 or higher MPIO driver installation and follow instructions 11. Restart system after the driver installation is completed Abb. 21 Abb. 22 12. After restart, start Windows device manager and check if the MPIO drivers are installed. Abb. 23 Abb. 24 17. Check if the driver version match the version in the release notes Abb. 25 Abb. 26 18. Start the Windows disk management console and check if the volumes are not longer listed twice, otherwise maybe you have to reinstall the MPIO drivers Abb. 27 Copyright MAXDATA GmbH Autor: Hasan Akkurt Datum: 26.08.2009 Seite 8