Cable Test Module ( HVT-25) Single-phase connection to object



Similar documents
Why Buy HVI VLF Products?

World Leader in HV Testing Technology

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Table of Contents. Fault Finding Solutions

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

5000V Graphical Megohmmeter Model 5070

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

O C M III. Open Channel Flow Monitor

Fluke Digital Multimeters Solutions for every need

HERZ-Thermal Actuators

Quick Connect. quick - simple - efficient.

RADIANT PLASMA 4700 Plasma Spark Generator

Dynatel 2273 Advanced Cable and Fault Locator

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

How To Sell A Talan

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

38 Series - Relay interface modules A

Current Probes. User Manual

Physical Specifications (Custom design available.)

AutoRanging Digital MultiMeter

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

MIT510/2, MIT520/2 and MIT1020/2

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Waveguide Access Point WGA631. Product Guide

38 Series - Relay interface modules A

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

SVPRIBOR ALFA DSL. Users Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Current Monitoring Kit QUICK START GUIDE

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Electrical Safety Tester Verification

Power Meter Series 700

Current Monitoring Kit

User's Guide. True RMS Industrial Multimeter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Fossil fuel heating equipment

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

15 Series - Electronic step relay and dimmer. Features SERIE

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Cable And Pipe Signal Receiver

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Electronic Control Devices The European Product Catalogue 2007

RigExpert AA-30 Antenna Analyzer (0.1 to 30 MHz) AA-54 Antenna Analyzer (0.1 to 54 MHz) User s manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

High Power Programmable DC Power Supplies PVS Series

A Practical Guide to Dielectric Testing

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Power Quality. Uninterruptible Power Supply

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

, User s Manual

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Single Channel Loop Detector

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

User s Manual AURORA 1.2K/2.2K

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Advanced Systems Tester 900AST

Multi-Function Ground

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Diesel Engine Driven Generators Page 1 of 6

Impedance 50 (75 connectors via adapters)

MasterINTERFACE 39 Series - Relay interface modules

MODEL 2202IQ (1991-MSRP $549.00)

i ChatterBox! Motorcycle Security

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

iva Cable & Antenna Analyzer

Operating Instructions

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Rack mounted telephone- and leased line modem for industrial applications

SMART SENSOR COLLECTION

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

GenTech Practice Questions

How To Use A Power Supply Unit (Upu)

SL Series AC and DC Electronic Loads

Duct Humidity Transmitter

Telephone- and leased line modem for industrial applications TD-36

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Insulation resistance testing. A complete solution for every person.

LOXONE 12 Channel Amplifier

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Transcription:

Number ФПА (VAT) 10132211L Holding company EMZ Head office and Factory: Free Trade Zone, Kalo Chorio, Larnaca, Cyprus RN HE 132211; IN 9.84 Cable Test Module ( HVT-25) Single-phase connection to object HVT-25 is intended for the following work performance: Tests of power cable lines with paper-oil insulation and operating voltage up to 25 kv; Tests of power cable lines from XLPE with operating voltage up to 25 kv; Fault locating in power cables with operating voltage up to 25 kv with the use of equipment and devices for preliminary and exact location. Laboratory performs the following functions: 1. Test of cables by the raised VLF voltage 0,1 0,02 Hz 2. Test of cables by the raised rectified voltage with the control of leakage current 3. Measurement of resistance of cables insulation 4. Burning of damages insulation of power cables 5. Measurement of distance to fault location in cable by pulse method and arc reflection method 6. Cable fault locating by acoustic method 7.. Cable fault locating by inductive method A. HIPOT TEST 1. MAIN EQUIPMENT. Laboratory equipment is provisionally subdivided into the main equipment (assembled) and additional equipment (completed). Such division allows planning buildup of laboratory functions, increasing its efficiency. A1. DC HIPOT TEST 1.1. Equipment DC Hipot / Megohmmeter PTS- 75F (USA) The PTS Series of Portable DC Test Sets are combination high voltage proof testers and high voltage Megohmmeters. Testing dielectric strength and insulation resistance is now served with one instrument that is designed and constructed with field use in mind. For letter: P.O. Box 41016 6308 Larnaсa, Cyprus Phone: + 357 24821788 secretary Fax: + 357 24821787 E-mail: vitald@cytanet.com.cy Internet: www.vitaldrive.net

Advantages of PTS Portable DC Test Sets: Five range current meter with a 0-1 ua low range for Leakage Current measurements 10 ma output current rating for fast charging Resistance measurements at any output voltage Regulated input for accurate, reliable results (ideal for field generator use) ± 1% stability with ± 10% line change Ripple less than 2.5% RMS Internal HV shorting solenoid with discharge resistor Continuous Duty Operation Automatic transit protected meters Rugged case with cushion grip handles and shorting stick included 1.2 Equipment AC Hipot VLF-4022CM(F) TECHNICAL SPECIFICATIONS A2. AC HIPOT TEST A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable. There is no better way to verify the AC integrity of a cable than to hipot it with AC voltage. VLF hipots are used to provide a go/no-go, or pass/fail, voltage withstand test. It can also be used as the voltage source for diagnostic cable testing. 2

FEATURES Portable and affordable/ Simple and easy operation True sine-wave output/ Highest load ratings available Waveform is independent of load capacitance between 0.01 mf and maximum load AC testing does not degrade good cable insulation Harmful space charges are not injected into the cable insulation No travelling waves are generated during testing Rugged and reliable design less prone to failure from transients Much easier to service compared to units with solid state design CONTROLLED ENERGY CAPACITOR DISCHARGE SYSTEMS SURGE GENERATOR/THUMPER 1.3. CDS-2010U With its 20kV output, the CDS-2010U is good for fault locating cables rated up to 35kv, having a line to ground voltage of 20kV. The high burn current of 400mA can be used to condition a fault to reduce its arc over voltage to permit thumping at a lower and less damaging voltage level, yet still at full energy. The CDS-2010U can thump a cable at just 5kV yet deliver 1000 joules. Find your fault without making more. There is no better thumper. The CDS-2010U offers the complete package: three full joule output voltages, three variable hipot outputs, the highest burn current, rapid discharge rate, tdr/radar ready, and its rugged design holds up to years of use. Another plus: all CDS Thumpers use EPR high voltage output cable rather than XLPE. EPR stays flexible in cold weather. FEATURES Single piece combination Hipot, Burner and Fault Locator Constant energy at each output voltage setting Variable discharge rate from 6 10 seconds Motorized output voltage tap switch Internal Arc Reflection Filter, standard on all units Simplified Controls for minimal operator training Highest burning capability, compared to other units of same size Single pulse or continuous discharge modes Side mounted storage reel to hold cables and accessories Output vise clamps for assured contact to test cable and ground Operation from either line, generator or inverter Manually operated internal heater to minimize excessive moisture buildup 3

VERY LOW FREQUENCY TESTING (VLF) B.1 Arc Reflection & Puls Reflection Methods 1.4.DIGITAL CABLE RADAR TDR-1669 The Digital Cable Radar is a multi-function cable fault locator and an excellent and highly accurate portable measuring instrument to check problem and distance to events on cable. The TDR-1669 shows the continuity of characteristic impedance along the cable under test applying electrical pulses, which is ideal for checking faults (such as complete open & short, partial open & short, loose connection, broken lines etc.) on any cables which consist of at least two metallic conductors. FEATURES Range up to 30km Adjustable pulse width from 50ns to 3µs TFT Enhanced color Liquid Crystal Display Two cursors for distance measurement Real time trace display Trace storage capability RS-232 interface for computer storage & printout / CD-ROM with software for downloading -reading measurements 4

TECHNICAL SPECIFICATIONS Measuring Range Continuously adjustable in 10% increments of displayed range Pulse Width Automatic with range selection Manual: 50ns, 100ns, 200ns, 1s, 2s, 5s, and 10s Exponential pulse shape for improved reflections on transformers and splices Sampling Rate 100 MHz Accuracy 1 Sample (crystal controlled) Screen High brightness color VGA TFT LCD, 8.4 (21 cm) diagonal Velocity of Predefined from cable menu Propagation Manual: 200 ft/s to 492 ft/s (61 m/s to 150m/s) Display Modes Real time mode (always visible) and stored trace Testing Modes TDR real time mode Distance Adjustable, with two vertical cursors Measurement Storage Over 100 traces may be stored and recalled Capability from internal disk User Setup Measurements in feet or meters (optional) Quick startup settings, APF and Easy Mode Power 90-230V, 50/60Hz input Requirements 12V DC External (Option) Operating -20 to 40 o C Temperature Dimensions 14 w x 10.5 d x 6.25 h, 12lbs and Weight 356mm w x 267mm d x 159mm h, 5.4 kg 1.4.1 CONNECTING DEVICE AR-20 (for stabilization of electric arc) It allows finding distance to the defect both by classic pulse, and by high voltage method with the use of pulses reflected from the arc in cable (method Arc Reflection). It gives the possibility to quickly find distance not only to the low resistance, but also to complicated high resistance faults in power cables without usage of burn down unit (in RF it got a name «nonburning method»). Connecting device is used for the application of this method (photo up right). 1.5. PORTABLE CABLE LOCATOR MEGGER L1070 B.2 Induction Method Capable of locating long or short ranges, inductive or conductive, active or passive, the L1070 delivers quick and accurate results with a user-friendly interface. A special design feature on the 5

L1070 allows the user to select and compare receiver information on two frequencies simultaneously, without having to return to the transmitter. The L1070 features push-button depth measurements up to 15 feet to quickly identify service depths prior to digging. A passive 60 Hz detection services as an excellent safety feature for identifying live underground primary and secondary utility cables. An optional ground return probe allows ground fault detection on unshielded electric services or sheath faults on telephone services through the technique of voltage gradient. FEATURES Multiple transmit/receive frequencies provide accurate long or short range locates. Push-button depth measurements up to 4.6 m quickly identify service depths prior to digging. Passive 60 Hz detection serves as an excellent safety feature for identifying live underground primary and secondary utility cables. Passive detection also allows convenient locating of energized electric services. High power at low frequency solves the difficult multipoint grounded utility locating problem. TECHNICAL SPECIFICATIONS TRANSMITTER Operating Frequency 82 khz, 8 khz, 815 Hz, and BOTH (815 Hz/82 khz) simultaneously Indicators AC Load Resistance Measurement, Low Bat Indicator, Low Bat warning modulated on output signal every 20 seconds Load Matching Automatic from 5 to 2000 Ohm Output Power Normal 0.6 W High 2.0 W 815 Hz and 8 khz Normal 0.2 W High 1.0 W 82 khz BOTH (815 Hz/82 khz) Normal 0.12 W +.06 W HIGH 1.33 W + 0.67 W Battery Type Disposable Eight 1.5 V D size alkaline Battery Life Disposable Continuous 8 to 15 hours depending on load, frequency and power setting Intermittent 40 to 60 hours depending on load, frequency and power setting. 25% duty cycle average Operating Temperature Range -4 to +133 F (-20 to +55 C) Dimensions 15.2 H x 12.7 W x 40.6 L cm Weight 3.6 kg with alkaline D cell Operating Frequency Antenna Mode RECEIVER 815 Hz, 8 khz, 82 khz, 50/60~(PASSIVE) Null-responding vertical coil Peak-responding horizontal coil 6

Current Measurement Operating and Storage Temperature Range Battery Type Battery Life Continuous Intermittent Signal Strength Gain Control Manual Note Dynamic Range Depth Measurement Automatic Dimensions Weight Display indicated relative current simultaneously between any two selected cables for target cable verification in a multi-conductor environment -20 to +55 C Six 1.5 V C size alkaline 40 hours 82 hours Auto power shutoff after 10 minutes of nonuse Analog LCD Bargraph. Absolute Digital Signal Strength readout from 0 to 999 Up/Down button for automatic centering and manual control Bubble-level triangulation for verification of automatic readout in congested environments Accuracy is dependent on site conditions, nonconcentric conductor shape, number of nearby conductors, and soil return currents 126 db Push-button 3 digit readout to 15 ft in feet/inches, (optional meter/centimeters to 4.6 m) 23.8 W x 9.3 W x 76.9 L cm 1.36 kg B.3 Acoustic Method 1.6.SUPER DIRECTIONAL ACOUSTIC DETECTOR AQUATRONICS S.D.A.D Ease and speed of fault finding with a thumper have been greatly enhanced with the addition of the S.D.A.D. The Super DAD conveys more information about the fault location, and faster, with the addition of new microprocessor controlled electronics that provide bright, easier-to-see-and-read signals - day or night. FEATURES Dual channel system designed to work with any brand thumper Ultra-high speed clock indicates direction to the fault Soft coil microphones (earth probes) with tri-pod bases for hard surface location Ballistic impulse detector visually confirms the presence of the thump 7

Three different modes of operation: Direction-to-fault, time-based distance to fault and fault depth indication 1.7.AUTOMATIC DATA LOGGER HVINC ADL The ADL-1 data logger is designed to monitor, record, and wirelessly download all test data from an HVI Very Low Frequency tester to a computer. Users now have the best of both worlds: economical and easy to use VLF testers along with full test data collection. Use a laptop on-site to watch and record the test or store all results in the ADL-1 for later downloading. Windows compatible only. C. Electrical Safety System 1.8. System providing electrical safety of laboratory s personnel: Module of grounding control Module of grounding control (further MGC) is intended for monitoring of connections quality in the circuits of protective and working grounding and prohibition of switching of functional modules in case of fault in grounding circuit. For additional control it is used a special grounding rod, which is put in the ground near the LVI. It is connected by insulated wire with terminal «AuE». Resistance of circuit between terminals of working and protective grounding of module MKZ (summarized resistance of wires of protective and working grounding and also places of their junctions), which must not exceed 10 Ohm. If the value is bigger than this it is actuated a blocking relay and on the control panel the indicator Grounding Control blinks off; Potential of terminal «Protective grounding» towards the potential of control grounding rod (actually potential of LVI body towards ground), which must not be more than 25 V. At the excess of this potential the blocking relay is also actuated, and on the control panel the indicator Ground Potential blinks off. D. High Voltage Connecting Device 1.9 MAIN SWITCH Carries out switching of CDS high-voltage outputs and Megohmmeter on high-voltage shielded cable. On the main switch there are switches automatically closing the high-voltage output to "ground" after the work is finished 1.10. BLOCKS OF CABLE DRUMS External connections of HVT-25 are provided with a feeding cable drum, grounding cable drum and a high voltage cable drum with a high voltage cable of 30 meters in length. At the requirement of a customer the length of cables can be increased. 8

Block of cable drums VD 4.137.001 - drum with feeding cable; - drum with grounding cable with a cross-section 25 mm 2, length of cable 30 m; - drum with high voltage shielded cable for rectified voltage testing up to 60 kv, the length of cable is 30 m; 1.11 POWER GENERATOR EISEMANN 7400 This modern petrol generator with electronic control unit is ideal for independent work on construction sites and for industrial, commercial or private operation. With a large fuel tank it guarantees up to 16 hours running time and offers excellent performance and at the same time it is very safe to use. Isolation control with cut-off in cases of emergency and a test button ensure that the safety requirements according to civil engineering standard GW 308 are met. It also complies with ecological standards. Reduced exhaust emission and low fuel consumption as well as its very silent operation make it a highly efficient generator. TECHNICAL SPECIFICATIONS Engine Honda GX 390 Super Silent Cylinder 1 Speed 3000 rpm Fuel Petrol Engine capacity 1.3 l Cooling (Engine/Generator) Air / Air Electr. capacity 3~ φ 1.0 6000VA Electr. capacity 1~ φ 1.0 5000VA Voltage 3~ 400V Voltage 1~ 230V Max. Current 3~ 9A Max. Current 1~ 22,5A Current 1~ (CEE) 22,5A Current 1~ (Schuko) 16A Max. starting current cos φ 0,6 16A Starting current with 20% 40A voltage drop Frequency 50hz Protection IP 54 Tank capacity 20 I Weight 108 kg Weight including battery 117 kg Dimensions (L x W x H) 740x500x350 mm Acoustic power L WA 98 db(a) Acoustic pressure (10m no load) 70 db(a) 9

E. VEHICLE 2. CHASSIS. Chassis of any car manufacturers are applied: Lay-out of equipment in the cable test module HVT-25 10

2.1 Vehicle body. The vehicle body is divided into two compartments: a high-voltage compartment and an operator compartment. High-voltage transformers, cable drums and other functional equipment are placed in the high-voltage compartment. There are also two tool cases for regular tools and accessories. Measuring and control devices, managing system for testing process are placed in the operator compartment. Here are also an operator table, chest for devices and tools necessary for the operator during working. In the operator compartment there are control panels for high-voltage testing, and also an armchair for the operator, devices and tools chests and shelves for the documentation. In the high-voltage compartment there are 3-phase main switching control panel HVS-60/3, the high-voltage block of cables CDS-2010, the cable drums and ets. Views to the high voltage compartment of the laboratory HVT-25 11

View to the operator compartment of the laboratory HVT-25 The laboratory has the following main distinctive features: The equipment is mounted in the noise and heat insulated vehicle body from plastic-glass sandwich panels with foam filler. This creates a comfort work conditions for the operator both in cold and hot climate. In the operator compartment it is mounted a working table of Eurodesk type which creates comfort conditions for measurements and their further processing and registration. In order not to touch the conducting parts the special partition separates the operator compartment from the high voltage compartment. The partition separates and working table of Eurodesk type from the high voltage compartment. Leading out of cables to the object is done through the special cable outlet hatch. 3. Technical documentation: 1. Operating Manual 2. Circuit Schematic Manual 3. Test calibration reports F. Documents G. Warranty & Service 4. Warranty: Warranty period 12 month. All spare parts will provide for 10 years. 5. Contacts: H. Contacts Please send your requests by e-mail: sales@vitaldrive.net; vitald@cytanet.com.cy ; vitald@vitaldrive.net or by phone/fax: +357 24 821788 / +357 24 821787 12