Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)



Similar documents
Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Individualized Quality Control Plan

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

IQCP GUIDELINES and TEMPLATE FOR GETTING STARTED

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Quality Requirements of a Point of Care Testing Service

XL-I 2011: Understanding and Explaining the CAP POCT Checklist: A Tool for Laboratorians to Use With POCT Staff

Clinical Laboratory Improvement Amendments (CLIA) How to Obtain a CLIA Certificate of Waiver

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

General. What is a laboratory test? What is a waived test?

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

CHAPTER 13. Quality Control/Quality Assurance

Individualized Quality Control Plan (IQCP) Frequently Asked Questions Date: May 5, 2015 (last updated 05/13/2016)

CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD

College of American Pathologists Accreditation for Public Health Laboratories

Standards for Laboratory Accreditation

TEST METHOD VERIFICATION AND VALIDATION

General Information. Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009

How to Verify Performance Specifications

LabGuide 71. Incident Management: Developing a Plan

Basic Lessons in Laboratory Quality Control

Mayo Central Laboratory for Clinical Trials A Division within Mayo Clinical Trial Services

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Best Practices for Maintaining Quality in Molecular Diagnostics Gyorgy Abel, MD, PhD

2009 LAP Audioconference Series. How to Prepare and Comply with Your Quality Management Plan

Flow Cytometry. CLIA Compliance Manual*

Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?

In vitro diagnostic reagent, calibrator and control material stability

Center for Clinical Standards and Quality/Survey & Certification Group

ASSURING THE QUALITY OF TEST RESULTS

Document and Record Control in a Hospital Clinical Laboratory

Blood Glucose Monitoring: The Facts about Accuracy

Incident Management: Developing a Plan

A Practical Guide to Internal Quality Control (IQC) for Quantitative Tests in Medical Laboratories

MEDICAL DEVICE GUIDANCE

Calibration Verification

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Managing POCT: Trying to Control Testing in an Out-of-Control Environment. William Clarke, PhD, MBA, DABCC Johns Hopkins School of Medicine 3/24/11

ADMINISTRATIVE MANUAL Policy and Procedure

2. Contact Person: Garo Mimaryan, MS., RAC 7 Technical Regulatory Affairs Specialist III 3. Phone Number: (914)

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

CLIA & Individualized Quality Control Plan (IQCP)

Quality Assurance for the Clinical Laboratory

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Onboard Quality Controls for the CoaguChek XS System

Transfusion Medicine: Checklists and Challenges

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Laboratory Director Responsibilities

Answers to Your Questions About Blood Bank Proficiency, Competency and QC Follow Up to April 28, 2016 Webinar

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

ILLINOIS DEPARTMENT OF CENTRAL MANAGEMENT SERVICES CLASS SPECIFICATION CLINICAL LABORATORY TECHNICIAN SERIES

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)

For In Vitro Diagnostic Use

Is Your Lab s Competency Assessment a Competent Assessment?

Simoa HD-1 Analyzer Troubleshooting Guide. USER Sep 2014 Software Version 1.3 Beta

GUIDELINES ON PREVENTING MEDICATION ERRORS IN PHARMACIES AND LONG-TERM CARE FACILITIES THROUGH REPORTING AND EVALUATION

Medical Laboratory Technician AAS Program

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

Everything you want to know about ISO 15189:2012 Medical Laboratories Requirements for Quality and Competence

Using and Maintaining Documents and Records. Finding the information when you need it

Content Sheet 5-1: Overview of Sample Management

SAMPLE. Verification of Comparability of Patient Results Within One Health Care System; Approved Guideline (Interim Revision)

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

SMF Awareness Seminar 2014

Automation is Here. Now How Do You Handle All the Data? Swedish Covenant Hospital Lab. Life IS Good

Point of Care Testing and Informatics: How to Prepare for the POCT Explosion

Vitamin B12. ADVIA Centaur System

State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist

Laboratory Quality Metrics

FMEA and FTA Analysis

ArtisanLink Staining System is an automated special stains slide

Validation of measurement procedures

Preparation "Clinical Laboratory Technologist and Technician Overview"

accreditation will it still be needed or will other schemes show up?

116 The Future Role of Laboratory Inspections and Accreditation. Sharon Ehrmeyer PhD, MT(ASCP)

Quality Assurance (QA) & Quality Control (QC)

DAIDS Guidelines for Good Clinical Laboratory Practice Standards

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

MEDICAL DIAGNOSTIC LABORATORIES, L.L.C Kuser Road * Hamilton, NJ Toll Free (877) * Fax (609)

Biochemistry Validation Form

Validation and Calibration. Definitions and Terminology

A Stability Program for the Distribution of Drug Products

James O. Westgard, PhD, 1,2 and Sten A. Westgard, MS 2. Abstract

What Does Having a FDA Cleared Pregnancy Test Mean?

Laboratory medicine as one of the pharmacists competencies

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

ST. VINCENT'S. MEDICAL CENTER St. Vincent's Healthcare

4/24/2015. Urgent, STAT, Super STAT, ASAP! Achieving timely lab testing for the Emergency Department. Learning Objectives.

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

CHAPTER 7 QUALITY ASSESSMENT

IMPACTS OF BLUE DROP CERTIFICATION ON WATER QUALITY TESTING LABORATORIES

Transcription:

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs) James H. Nichols, PhD, DABCC, FACB Professor of Pathology, Microbiology, and Immunology Medical Director, Clinical Chemistry Associate Medical Director of Clinical Operations Vanderbilt University School of Medicine Nashville, TN 37232 5310 james.h.nichols@vanderbilt.edu

Overview Define Quality Control Define risk management and its application to clinical laboratory testing Understand common sources of error in the laboratory and mechanisms to reduce risk. Use the CLSI EP23 document as a resource for developing a quality control plan 2

Audience Poll Physician calls questioning a positive ethanol result of 135 mg/dl in a patient on the liver transplant list. A positive result would remove the patient as a candidate. This was first occurrence and patient is an adamant teetotaler! Repeat analysis of the specimen was negative (<10 mg/dl). Further investigation revealed that the technologist calibrated the assay backwards by switching positive and negative calibrators (Hi cal labeled #1 and Low cal labeled #2). Controls did not pick up, as they were switched as well. What should you do? A. Chastise the technologist B. Contact manufacturer to determine how the assay calibrated without error C. Seek better quality control D. Run for cover under risk management umbrella 3

Quality in Laboratory Results Clinicians rely on laboratory results for medical decision making. Quality is an essential component of laboratory testing. Errors in laboratory results can lead to missed diagnosis, medical mismanagement and increased cost of care. 4

Definitions Quality assurance in pathology and laboratory medicine is the practice of assessing performance in all steps of the laboratory testing cycle including pre analytic, analytic, and post analytic phases to promote excellent outcomes in medical care. Quality control is an integral component of quality assurance and is the aggregate of processes and techniques to detect, reduce, and correct deficiencies in an analytical process. Quality improvement is the practice of continuously assessing and adjusting performance using statistically and scientifically accepted procedures. College of American Pathologists 5

Historical Quality Control Quality control historically used to document stability of an analytical system (environment, operator, and analyzer). Born from the 1950 s industrial model of quality in analytical process Quality control is a stabilized surrogate sample analyzed like a patient sample containing known amount of measured analyte. If the analytical system can achieve the desired result using the QC sample, then the system is stable and quality patient results are being produced. 6

ISO QC Recommendations ISO 15189 5.6.1 The laboratory shall design internal control systems that verify the attainment of the intended quality of results. Special attention should be paid to elimination of mistakes in the process of handling samples, requests, examinations, reports, etc. Documentation should include quality control procedures based on manufacturer instructions for use. Internal Quality Control (internal to the laboratory) is defined as a set of procedures undertaken by laboratory staff for the continuous monitoring of operation and the results of measurements in order to decide whether results are reliable enough to be released. The regular analysis of QC materials can serve as an essential component of a laboratory s internal control system. 7

Cape Clinic Laboratory L-J Chart for XYZ Chemistry Analyzer Analyte: Glucose Control Material: Level 1 Units: mmol/l Lot #: 3-123 Exp Date: 19/4/20XX assign 3.48 SD assign 0.05 From: June 1, 20XX Through: June 30, 20XX Target Value 3.39 TEa 6.90% 3.63 +3 SD C o n t r o l V a l u e 3.58 3.53 3.48 3.43 + 2 SD + 1 SD X - 1 SD 3.38-2 SD 3.33-3 SD Run 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Quality Control A stabilized surrogate sample of known concentration analyzed like a patient sample to determine assay recovery and result stability over time Advantages QC has target values, if assay recovers target, then everything is assumed stable (instrument, reagent, operator, sample) QC monitors the end product (result) of the entire test system Disadvantages Failure to analyze QC periodically or take action when QC fails Possible to release patient results before a problem is detected particularly with autoverification or continuous release automated tests With autoverification or continuous release of results When problem detected must go back and reanalyze patients since last good QC and possibly send out corrected results. Clinical action could be taken on erroneous results in the interim of correcting an unrecognized issue! 9

QC and Error Detection Systematic errors affect every test in a constant and predictable manner Can occur from one point forward or for a limited period of time QC samples do a good job at detecting systematic errors, like: Reagent deterioration or preparation Improper storage or shipment conditions Incorrect operator technique (dilution, pipette setting) Calibration errors wrong setpoint, factors Random errors can also be detected by increased QC variability, but QC does a poor job overall at detecting random errors! 10

Audience Poll Oncology clinic calls to question 6 patients from earlier this day. Patients showed low sodiums (118 128 mmol/l) when repeated later in day, sodiums were higher by at least 10 mmol/l (128 138 mmol/l) [reference range 135 145 mmol/l]. Quality control showed a low trend earlier that day after morning calibration, but QC was acceptable. Medical director review noted QC ranges (120 +/ 3 mmol/l) were wider than CAP PT acceptability limits of +/ 3 mmol/l. This allowed for a 4 SD shift of nearly 12 mmol/l and still be acceptable! Analyzer had been in use for past 6 months without issue, and had adopted QC ranges from previous analyzer. What should you do as laboratory director? A. Resign B. Contact risk management C. Rerun all patient samples from period of low QC trend and correct any results outside CAP limits of +/ 4 mmol/l D. Revise the QC ranges 11

Quality Control Laboratory QC has limitations: Range for QC must be established by laboratory Setting ranges too wide can allow imprecision or too much method variability Incorrect establishment of control means can allow test result biases Biases in a single laboratory would go undetected without inter laboratory comparison (PT or External Quality Assessment Schemes EQAS) 12

New CMS QC Recommendations Analyze at least 2 levels of QC (different concentrations) with each batch of patient samples Minimum of 2 levels of QC each day of testing Hold patient results and troubleshoot test performance when QC fails to recover expected range of results. OR Develop an Individualized QC Plan (IQCP) based on risk management (US Centers for Medicaid and Medicare Services recommendations starting in 2014) 13

History CLSI EP23 document introduces industrial and ISO risk management principles to the clinical laboratory CMS adopted key risk management concepts to develop the IQCP option for quality control IQCP allows laboratories to develop a plan that optimizes the use of engineered, internal control processes on a device and the performance of external liquid QC 14

Why Should Labs Care About CLSI EP23? New generation of laboratory devices contain a variety of internal control processes. Labs are challenged with deciding appropriate liquid QC interval given QC engineered into newer devices. Package inserts provide little help from the manufacturer.

Package Inserts Current Good Laboratory Practice includes the daily use and documentation of either liquid controls or electronic internal controls to assure that the calibration of the diagnostic device is maintained within acceptable limits. (ffn test) Good Laboratory Practice suggest that external controls should be tested with each new lot or shipment of test materials, and as otherwise required by your laboratory s standard quality control procedures. (hcg test)

Package Inserts For quality control use the control materials listed. Other suitable control material can also be used in addition. The control intervals and limits should be adapted to each laboratory s individual requirements. (CO2 reagent) For best results, performance of reagent strips should be confirmed by testing known negative and positive samples, or controls whenever a new bottle is opened. Each laboratory should establish its own goals for adequate standards of performance and should question handling and testing procedures if these standards are not met. (Urine dipsticks)

Definitions Risk management is a way for labs to develop an individualized QC plan for their tests. A Quality Control Plan from CLSI EP23 a document that describes the practices, resources, and sequences of specified activities to control the quality of a particular measuring system or test process to ensure requirements for its intended purpose are met. An Individualized Quality Control Plan (IQCP) from CMS CLIA Interpretive Guidelines anew quality control option based on risk management for CLIA laboratories performing nonwaived testing. 18

Risk Management Definition Systematic application of management policies, procedures, and practices to the tasks of analyzing, evaluating, controlling, and monitoring risk (ISO 14971) 19

Risk Definition Risk the chance of suffering or encountering harm or loss (Webster s Dictionary and Thesaurus, 1993 Landoll, Ashland, Ohio) Risk can be estimated through a combination of the probability of occurrence of harm and the severity of that harm (ISO/IEC Guide 51) Risk essentially is the potential for an error to occur 20

Quality There is no perfect device, otherwise we would all be using it! Any device can and will fail under the right conditions Any discussion of risk must start with what can go wrong with a test (errors) Lab tests are not fool proof!

What Could Go Wrong?

Sources of Laboratory Error Test System: Reagent contamination, deterioration, lot variation Reaction fluctuations Inadequate sampling Improper or loss of calibration Electronic or mechanical failure Power supply Environment: Temperature and airflow Humidity Light intensity Altitude Operator: Improper specimen prep, handling Incorrect test interpretation Failure to follow test system instructions CLIA Interpretive Guidelines for Laboratories. Appendix C, Subpart K. 493.1256 Standard: Control Procedures. Interpretive Guidelines 493.1256(a) (c). http://www.cms.gov/regulations-and- Guidance/Legislation/CLIA/Interpretive_Guid elines_for_laboratories.html

Fishbone Diagram from CLSI EP23 Refer to Appendix A in CLSI EP18 for more comprehensive list of error sources

Managing Risk with a Control Process Once we identify the risks, we need to detect and prevent those errors from harming the patient. Control processes reduce risk by enhancing detection of errors or limiting harm if errors go undetected. Control processes can take many forms from liquid quality control to engineered checks within a device

Types of Quality Control On Board or Analyzer QC built in device controls or system checks (IL GEM, Radiometer ABL80, i stat) Internal QC laboratory analyzed surrogate sample controls. (Manufacturer controls performed on kit) External QC blind proficiency survey, samples sent a few times a year to grade an individual laboratory s performance against other labs (CAP or Wisconsin State) Other types of QC Control processes either engineered by manufacturer or enacted by laboratory to ensure result reliability (reagent barcoding to prevent use of expired reagent) 26

27

Quality Control No single quality control procedure can cover all devices, since devices may differ in design, technology, function, and intended use. QC practices developed over the years have provided labs with some degree of assurance that results are valid. Newer devices have built in electronic controls, and onboard chemical and biological controls. Quality control information from the manufacturer increases the user s understanding of device overall quality assurance requirements so that informed decisions can be made regarding suitable control procedures. ISO 15198:2004 Clinical laboratory medicine: In vitro diagnostic medical devices Validation of user quality control procedures by the manufacturer. 28

CLSI Project: EP23 Laboratory Quality Control Based on Risk Management. James H. Nichols, Ph.D., Chairholder EP23 describes good laboratory practice for developing a quality control plan based on manufacturer s information, applicable regulatory and accreditation requirements, and the individual healthcare and laboratory setting 29

EP23 Laboratory QC Based on Risk Management Input Information Medical Requirements for Test Results Regulatory and Accreditation Requirements Test System Information: Provided by the manufacturer Obtained by the Laboratory Information about Health Care and Test-Site Setting Process Risk Assessment Continuous Improvement Output Laboratory Director s QC Plan Post Implementation Monitoring CLSI EP23 Table 30

Individualized Quality Control Plan Quality Control Plan Risk Assessment Quality Assessment Individualized Quality Control Plan 31 CLIA

Benefits of IQCP to Lab Single use cartridge based methods use engineered controls in lieu of 2 levels QC/day POCT analyzers perform QC by lot of cartridge (using subset of devices) rather than every lot and each device. Core lab analyzers higher complexity tests helps labs identify weaknesses and appropriate actions to reduce risk of error (may need >2 levels QC/day) 32

Audience Poll As laboratory director, you are reviewing monthly temperature logs and notice a problem. The 20 C freezer logs showed temperatures out of range for past several days (ranging 16 C to 19 C for expected temps of < 20 C), with no corrective actions. Lead signed off the monthly log. When approached, the lead tech looks baffled and indicates that 16 C is colder than 20 C so no corrective action. You explain this problem to the manager who approaches the other techs involved with similar amazement. What do you do? A. Fire the techs involved and hire more competent staff B. Retrain the techs on negative numbers, put a number line as reminder on the freezer door, and change < 20 C to a range. C. Discard all the controls and calibrators stored in the freezer and call for maintenance D. Move the controls and calibrators to a working freezer and continue to use them. If controls are in, they are still good. 33

Summary Anything can and will go wrong without robust control plans! A quality control plan simply summarizes the risk for potential errors with a device and how the lab intends to address those risks. A quality control plan can be high level or very detailed depending on the device, the laboratory, and clinical application of the test result and may vary from one lab to next. Risk management and developing QC plans are generally accepted by the industry and required for FDA test approval Once implemented, the quality control plan is monitored for effectiveness and modified as needed to maintain risk to an acceptable level. 34

Where s the Quality Control? 35

Review Questions Which device would best benefit from an individualized quality control plan? A A glucose meter where manufacturer recommends daily QC B A high volume chemistry analyzer requiring QC 3 times daily C A molecular test with 500 reactions occurring on a single use cartridge D A batch analyzer for infrequent therapeutic drug testing Which errors would most likely be detected by traditional liquid QC? A A mistake where the assay pipette is set to the incorrect volume B Drug interference in a patient s sample C Hemolysisin a neonatal specimen D A clot in a dialysis patient sample Staff approach the medical laboratory director with a problem. During maintenance on Monday morning, a brown precipitate was found in the acid wash buffer which cleans all the cuvettes. It appears sometime over the weekend, staff poured an assay reagent into the wash buffer. What is the best course of action? A Fire the weekend staff B Call the manufacturer to determine how to flush the analyzer C Verify the validity of the weekend quality controls and reanalyze all the samples, correcting results as necessary D Contact risk management 36