METABOLOMICS: LC-MS ANALYSIS DEVELOPMENT



Similar documents
Supplementary Materials and Methods (Metabolomics analysis)

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Chemical analysis service, Turner s Green Technology Group

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Introduction to mass spectrometry (MS) based proteomics and metabolomics

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Waters Core Chromatography Training (2 Days)

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

How To Test For Contamination In Large Volume Water

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Overview. Purpose. Methods. Results

A Streamlined Workflow for Untargeted Metabolomics

L. Yu et al. Correspondence to: Q. Zhang

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Plant Metabolomics. For BOT 6516

Introduction to Proteomics 1.0

Expectations for GC-MS Lab

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Pep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics

Mass Frontier 7.0 Quick Start Guide

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

LC-MS/MS for Chromatographers

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Mass Spectrometry Based Proteomics

WATERS QUANTITATIVE ANALYSIS solutions

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

High Resolution LC-MS Data Output and Analysis

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Analyzing Small Molecules by EI and GC-MS. July 2014

Electrospray Ion Trap Mass Spectrometry. Introduction

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Pesticide Analysis by Mass Spectrometry

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Thermo Scientific SIEVE Software for Differential Expression Analysis

AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE

for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry

Introduction to Proteomics

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

How To Develop A Recipe Card

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Chapter 14. Modeling Experimental Design for Proteomics. Jan Eriksson and David Fenyö. Abstract. 1. Introduction

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Quantitative proteomics background

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Structural Analysis of Labeled N-Glycans from Proteins by LC-MS/MS Separated Using a Novel Mixed-Mode Stationary Phase

Transcription:

METABLMICS: LC-MS ANALYSIS DEVELPMENT V.V. Tolstikov 1, N. Tanaka 2 and. Fiehn 1 1 - Max Planck Institute of Molecular Plant Physiology, Dept. Lothar Willmitzer, 14424 Potsdam, Germany 2 - Kyoto Institute of Technology, Department of Polymer Science and Engineering, Matsugasaki, Sakyo-ku, Kyoto 66-8585, Japan INTRDUCTIN Metabolomics, the comprehensive analysis of metabolites present in a biological sample, has emerged as the third major path of functional genomics besides transcriptomics (mrna profiling) and proteomics (Fiehn, 22; Sumner et al., 23; Jan van der Greef et al., 23). Combined with the information obtained on transcriptome and proteome, this would lead to a nearly complete molecular picture of the state of a particular biological system at a given time. Monitoring the biological system state as a function of time by above mentioned methods would allow the study of the temporal dynamics of the system homeostasis. The importance of metabolites in control, communication and as building blocks and energy transporters within the biological system provides metabolomics a unique opportunity for phenotypic and dynamic profiling. The analysis of metabolome is dramatically more complex than gene expression analysis. There is an enormous chemical diversity of an organism s metabolome as well as a large concentration range to be covered. This presents a considerable challenge for the development of an appropriate analytical technique. ver, metabolites are described in the plant kingdom, and it can be assumed, that the number of metabolites of an individual plant species may easily reach some 5, individual lowmolecular weight compounds. In plant biology and plant functional genomics, most academic and many industrial research groups use the small weed dicotyledonous plant Arabidopsis thaliana or the important monocotyledonous crop rice (ryza sativa) as models to tackle fundamental and applied research objectives. Both species are frequently used for plant functional genomics since complete genome sequences and functional gene annotations are publicly available. The most common and mature technique is GC-MS analysis. ver 3 metabolites were covered in a proof-of-concept study on functional genomics in Arabidopsis, using GC-MS technology. Although it has been shown that the number of detected peaks in typical GC-MS plant chromatogram can be multiplied by deconvolution algorithm, the de novo identification of GC-MS peaks remains cumbersome. Therefore, needs for development of the complementary technique allowing plant sample analysis without chemical modification and providing enhanced qualitative characterization of the components are clear. During the last decade, LC-MS techniques were developed employing soft ionization methods like electro spray (ESI) or photo ionization (APPI) and, simultaneously, mass spectrometers became both more sophisticated and more robust for daily use. More recently, achievements in separation sciences propose much better solutions for the separation of the complex mixtures than it was attainable before. Specifically, the advance of preparation of monolithic columns enabled the separation of the very complex mixture separations due to the high number of theoretical plates of these columns (Tanaka, 21). The objective of this study was to develop LC-MS methods of analysis suitable for the plant metabolomics studies, and to apply this for Arabidopsis and rice plants.

MATERIALS AND METHDS Samples Application examples for LC-MS analysis were cold methanol extracts of the grounded leaves of Arabidopsis thaliana Col- and rice (ryza sativa) grown in the green house. At this stage, no specific biological question was followed. LC-MS^n In our present studies, we have used the LC-MS system consisted of a Finnigan LCQ DECA mass spectrometer (ThermoFinnigan, San Jose, CA, USA), a Rheos 2 pump (Flux Instruments AB, Karlskoga, Sweden), and an HTS PAL auto sampler (CTC Analytics, Zwingen, Switzerland). The system was operated under the Xcalibur software (version 1.3, ThermoFinnigan, USA). Data acquisition has been done in positive and negative modes. Chromatography was performed using 6.5 mm ammonium acetate (ph 5.5, adjusted by acetic acid) (A) and highest grade acetonitrile available (Biotech grade solvent, 99,93+%, (SAF), Seelze, Germany) (B), as the mobile phases. Reverse-phased (RP) split chromatography was used for capillary monolithic column at the flow rates of 5-12 µl/min at ambient temperature. LC-MS analysis was performed on monolithic capillary silica based C18 column (6 x.2mm ID). With the pre-column split ratio 1:1 mentioned above flow rate provided 5-12 µl/min actual flow rate through the capillary column. Separation was accomplished by stepwise gradients from 5% B to % B at 75 min followed by isocratic elution. Hydrophilic interaction chromatography (termed HILIC, see Tolstikov, 22) was performed on PolyHYDRXYETHYL A (PolyLC, USA) columns (4,6x mm, A, 3 µm particles size and,2x mm, A, 3 µm particles size). RESULTS AND DISCUSSIN Reliable and reproducible GC-MS technique for metabolomics studies is suffering from certain limitations. Specifically, the upper mass limit of metabolites can hardly be increased over the range of trisaccharides due to volatility constraints, which is well below the mass of membrane lipids, or lots of secondary metabolites. Furthermore, metabolites usually require derivatization, which on the one hand may already adversely affect certain compound classes and on the other hand hampers de novo identification of unknown compounds tremendously. Complementary techniques are capillary electrophoresis or liquid chromatography coupled to mass spectrometry (LC-MS). A number of problems arise from current LC-MS protocols for metabolic profiling. Some of these problems are related to the LC separation itself, others are connected to the MS detectors used. In general, mass spectrometers are able to detect a large number of the compounds simultaneously, even if these are co-eluting. Selectivity is gained by identification and quantification of the compound s specific molecular masses and fragmentation pathways. However, mass spectrometers can only detect ions, with the result, that any quantification will adamantly demand that there is perfect ionization of all compounds throughout the chromatogram. Unfortunately, this is not the case. It is well known among mass spectrometrists, that one compound can hamper the ionization efficacy of another, even if these are chemically related and co-elute at the same time. Therefore, ultimate separation is needed to ensure robust quantification, especially for very complex mixtures consisting of hundreds of components to be analysed and quantified. Figure 1 shows analyses of 15 C cold methanol extracts of mg fresh weight of grounded leaves of Arabidopsis thaliana by monolithic C18 reversed phase LC-MS. Compared to other plant species such as rice (ryza sativa), lipophilic metabolic profiles varied largely in abundance and identity of detectable metabolites which is in accordance with background knowledge of comparative genomics between different species. For example, glucosinolates only occur in Brassicaceae like Arabidopsis, and are absent from all other species. In general, many important lipophilic compound classes can be observed such as glucosinolates, flavonoids,

phenolics, anthocyanines, major and minor components of membrane lipids, porphyrins, chlorophylls and their allomers, and miscellaneous and unidentified compounds. 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 22,2 2 4 6 8 39,8 41,35 45,38 38,2 49,5 55,47 432,9 H 3 C H 287, 413,9 2 4 6 8 m/z 8,26 H CH 3 15 1 5 95 9 85 8 75 7 65 56,99 36,14 59,6 75,19 68,82 35,65 22,25 65,14 21,1 33,92 3,8 29,69 87,53 5,34 16,57 9,94 1 2 3 4 5 6 7 8 9 24,29 54,74 6 499, H 55 548, 44,2 5 529, 45 1 2 3 4 5 6 7 8 9 457, 4 481, 49,1 445,1 469, 493,2 511,1 427,1 35 53,1 3 23,4 4 42 44 46 48 5 52 54 56 58 25 47,41 m/z 4,28 2 24,84 76,34 15 8,3 75,56 1 27,83 52,59 59,361,34 5 71,29 81,58 22,52 28,7 2,5 37,29 88,87 9,71 17,8 98,4 1 2 3 4 5 6 7 8 9 H H H 547, Figure 1. RP/LC-MS chromatograms. Column dimensions are.2mm ID x 6mm length. Upper panel: Arabidopsis leaf extract. Lower panel: Rice leaf extract. Examples for specific extracted ion chromatograms are located in the upper left corners. Compound identifications by MS^2 spectra and corresponding structures are situated in the upper right corners. In this respect, a good coverage of the plant lipophilic and secondary metabolome is achieved. Under the current electro spray conditions, carotenoids do not produce ions and were only detectable using LC post-column flow splitter and UV-VIS detection. The identification process has been described earlier (Tolstikov, 22) and is mainly based on the fragmentation study and off-line accurate mass measurements, off-line NMR studies, followed by a reconstruction of the molecular structure, in the case where there are no standards available to compare with. A further example of metabolic profiling with the use of currently developed LC-MS technique is shown on Figure 2, demonstrating the results of a cold acclimation experiment performed on Arabidopsis thaliana seedlings. Anticipated metabolic changes such as increase in raffinose family oligosaccharides were directly observable from visual

1,26 35,24 2,16 6,7 1,48 25,97 29,6332,78 4,9 23,2 14,33 43,75 15,39 39,74 48,85,68 1 2 3 4 5 6 31,32 38,53 19,5 52,43 3,28 55,43 65,7 41,21 28,31 18,61 6,6869,66 5,54 26,89 72,28 8,81 1 2 3 4 5 6 7 8 9 5,93 35,33 1,24 13,94 26,2 33, 31,41 19,3 38,73 1,45 4,78 43,85 53,96 23,3 17,3 39,86 52,6 56,34 1 2 3 4 5 6 17,37 3,39 43,19 55,54 56,32 28,4 1,74 16,87 57,79 69,6972,39 84,16 1 2 3 4 5 6 7 8 9 Figure 2. RP and HILIC -MS chromatograms. Upper panel: control plant. Lower panel: cold acclimated plant. Left column: HILIC capillary column. Right column: RP capillary monolithic column. inspection. A more detailed investigation revealed that more than 2 peaks/components were statistically significantly different between cold acclimated plants samples compare to controls. The relative quantification of the detected components has been done with the assistance of LCQuan software (ThermoFinnigan, USA, included in Xcalibur 1.3 package) by calculation of peak areas for each pre-defined target compound. External standards have been used for calibrations. Peak height/area of a number of components changed reflecting changes in the metabolite concentrations in the sample. Eventually, such changes can be interpreted in terms of alteration of biochemical processes. With respect to metabolome coverage, the total number of detectable peaks is particularly interesting. A careful manual and scan-wise inspection of peaks using the instrument s Xcalibur software revealed about 2 distinct components found on chromatogram for the Arabidopsis extract recorded for RP/LC-MS analysis with the use of monolithic column, positive/negative ionization switching and MS/MS triggering. By applying mass spectral deconvolution with Mass Frontier 3. software, 16 peaks were found in positive electro spray mode. Unfortunately, MS deconvolution on continuous positive/negative ionization switching is not possible with any software available to date. This would be highly advantageous since many components are much more efficiently ionized in negative mode than in positive that strictly depends on the chemical structure of the ionized compounds.

13,36 45,91 4,22 12,39 17,3 46,29 45,69 3,54 26,71 19,79 17,9 2,33 11,29 25,46 64,97 8,92 32,1635,35 7,27 79,15 37,4 5,49 59,44 1 2 3 4 5 6 7 8 58,76 11,44 14,32 65,32 7,77 79,1 28,23 4,51 36,4 49,14 1 2 3 4 5 6 7 8 RT: 46,12 RT: 45,85 51649614 166657452 RT: 58,76 41958186 66365458 RT: 58,76 3 35 4 45 5 55 6 65 7 35 4 45 5 55 6 65 7 Figure 3. HILIC-MS chromatograms. Upper panel: full chromatogram. Lower panel: sucrose (Rt 46 min) and raffinose (Rt 59 min) peak area on extracted chromatograms for positive ions. Left column: rice leaf extract. Right column: rice grain extract. Figure 3 illustrates HILIC -MS analyses of methanol extracts of rice (ryza sativa) leaf and rice grain. The analysis of compounds of specific interest is done either on extracted ion chromatograms or on MS^2 transitions. n the lower panel, the determination of a reduced amount of sucrose by extracted ion monitoring is demonstrated concomitant with an elevated amount of raffinose in grain compare to leaf extract. CNCLUSIN In conclusion, we have briefly described LC-MS methods for plant metabolomic studies based on RP and HILIC chromatography. This technique is complementary to established GC-MS metabolomic profiling and provides unique information on compound identity and mass ranges. We believe the reported data supports the successful integration of capillary silica based monolithic C18 columns into current reversed phase LC-MS protocols. ACKNWLEDGEMENTS This work was financially supported by Metanomics GmbH & Co. KGaA, Berlin, Germany, and by the project fund Development of micro HPLC for post-genomic analysis", provided by the Ministry of Economy, Trade and Industry, through Kansai Bureau of Economy, Trade and Industry, and saka Science and Technology Centre. REFERENCES Fiehn,. (22). Plant.Mol.Biol. 48: 155-171.

Jan van der Greef, Eugene Davidov, Elwin Verheij, Jack Vogels, Rob vander Heijden, Aram S. Adourian, Matej resic, Edward W. Marple and Stephen Naylor (23) The Role of Metabolomics in Systems Biology. George G. Harrigan & Royston Goodacre (eds.) Metabolic Profiling: Its Role in Biomarker Discovery and Gene Function Analysis. Boston/Dordrecht/London: Kluwer Academic Publishers 171-198. Sumner, L.W., Mendes, P. and Dixon, R.A. (23). Phytochemistry, 62: 817-836. Tanaka, N., Kobayashi, H., Nakanishi, K., Minakuchi, H., Ishizuka, N. (21) Anal. Chem. 73: 42A-429A. Tolstikov, V.V., Fiehn,. (22). Anal.Biochem. 31:298-37. Tolstikov, V., Costisella, B., Weckwerth, W., Zhang, B., Fiehn,. (22) Proceedings 5 th ASMS Conference on Mass Spectrometry and Allied Topics, Carbohydrates and Glycoconjugates, 146.