Reducing the Cost of Keeping Office Data Centers Cool



Similar documents
Using Portable Spot Air Conditioners in Industrial Applications

MovinCool Office Pro Series. The Portable Spot Cooling Solution

The Different Types of Air Conditioning Equipment for IT Environments

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

air conditioners how to choose a cooling system

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Commercial Portable Air Conditioners

Lesson 36 Selection Of Air Conditioning Systems

APC APPLICATION NOTE #112

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

SECTION MORTUARY REFRIGERATORS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION HEAT PUMPS

THREE. Heating and Cooling

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Energy Efficiency. Energy Efficient Home Cooling:

FOXAIR 60/50 ALL MODELS

USER S MANUAL HSC-24A

Ductless Heat Pumps. Gary Nordeen January

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Air-Conditioning Buying Guide

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Why Daikin? 2015 Houston, Texas USA

Single Zone LCD Thermostat Operating Instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Tech Byte 27: Small Computer Room and IT Closet Cooling

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Element D Services Heating, Ventilating, and Air Conditioning

Dehumidification Frequently Asked Questions

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Creating Efficient HVAC Systems

Chilled Water HVAC Systems

SECTION AIR CONDITIONING UNIT

Portable Air Conditioner

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Energy Efficiency in Industrial HVAC Systems

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

- White Paper - Data Centre Cooling. Best Practice

Basic Technology Series

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center

Glossary of Heating, Ventilation and Air Conditioning Terms

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Air Conditioning System

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Get the FACTS about SEER and Deliver Better Customer Value

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Selection Tips For Air-Conditioning Cooling Systems

Why Do I Need Precision Air Conditioning?

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Air Conditioner Water Heater Model ACWH18

Low Profile Unit Cooler

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

How To Improve Energy Efficiency In A Data Center

MAC-120HE-01 Air-Cooled Chiller

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

ECOCIAT. Domestic hot water heat recovery unit

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Air Conditioning Contractors of America

Choosing Close-Coupled IT Cooling Solutions

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Benefits of. Air Flow Management. Data Center

How To Understand Evaporator

Nirvana. Cycling Refrigerated Dryers

HEATING, VENTILATION & AIR CONDITIONING

HVAC Systems: Overview

LOBOY 16 AIR CONDITIONERS

Bring the fresh in. Dedicated Outside Air Systems

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Variable Refrigerant Flow Systems

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Poor Performing AC? High Electric Bills? High Humidity?

Evaluate, Clean, and Tune Guidance

10 tips for getting more reliability from your air-conditioning system [reliability]

COMPRESSOR REPLACEMENT PROCEDURE

WINDOW ROOM AIR CONDITIONER

Transcription:

Reducing the Cost of Keeping Office Data Centers Cool Portable Spot Air Conditioners as Permanent Cooling Solutions A Guide for Facility Managers, IT Managers and Mechanical Contractors Today s office data centers have specialized air-conditioning needs. As businesses increasingly rely on computers and telecom equipment to help run more and more aspects of their operations, they often find that the many pieces of IT equipment they have accumulated need to be housed in an office data center. Even for small to medium-size businesses, such data centers can easily contain four or more racks of equipment, which is both heat-sensitive as well as a source of considerable heat itself. This equipment must be kept cool in order to prevent it from malfunctioning or incurring expensive damage. Even more serious consequences can result when a heat-related IT equipment failure causes a business interruption. A building s central air-conditioning system can sometimes provide the necessary cooling for an office data center, but it is usually expensive and a wasteful use of energy. This is especially so since most data centers operate continuously, including times when the building is unoccupied and does not otherwise require cooling, such as after business hours, on weekends and holidays. Moreover, the temperature in the data center usually needs to be kept lower than the rest of the office space, and its higher heat-load requires more cooling power. Unless air conditioning Copyright 2009 MovinCool / DENSO Sales California, Inc. 1

Providing air conditioning for office data centers in leased office spaces presents new challenges. can be delivered separately to the data center, this can be uncomfortable for employees working in other parts of the office. In addition, during cool-weather months, if the central air conditioning system switches to heating mode, the data center and its equipment will be heated along with the rest of the building. For all these reasons, data centers usually require their own dedicated air-conditioning system. Yet the traditional choices precision-cooling or mini-split systems involve costly installation and have other drawbacks. Many office data centers are in leased space. Here, the lease agreement may prohibit a split precision-cooling or mini-split system. These usually require cutting openings in the roof or an outer wall, as well as interior walls, through which copper connecting pipes can be run. The pipes require sweating and brazing to connect them, and the units need to be charged with refrigerant, adding considerably to the installation cost. Self-contained precision-cooling systems are available that do not require external piping, but they are more expensive and require significant other installation work that a lease agreement may also prohibit. Another problem with split systems is that they require a suitable place outside the building where the condensing unit can be installed. Especially with mini-splits, the distance and height differential between the indoor evaporator and the outdoor condensing unit cannot be too great. Even in the absence of lease restrictions, this effectively rules out split systems in many situations, particularly in high-rise buildings. It can also rule out many split systems in low-rise buildings if the data center is located on one side of the building, but the condensing unit needs to be installed on the other, or where the refrigerant piping needs to go up over a wall. In these cases, the split system may not be powerful enough to pump the refrigerant the necessary distance or height. Fortunately, a class of industrial air conditioners, called portable spot air conditioners or spot coolers, can provide a simpler, more convenient and less costly solution. Even though these self-contained units are portable, some manufacturers specifically design their spot coolers for heavy-duty, 24/7 usage, with a mean time between failures (MTBF) that may actually be longer than that of a non-portable, fixed system. This paper will examine the benefits of using portable spot air conditioners as a less-expensive alternative to precision-cooling systems and mini-splits. Copyright 2009 MovinCool / DENSO Sales California, Inc. 2

Continued Growth in the Use of IT Equipment Computer and telecom equipment continue to become more and more essential for an ever-widening range of business functions, including general operations, accounting, Internet transactions, e-mail and telephone communications. The dynamic growth in the number of pieces of electronics equipment used by businesses to perform these functions means that dedicated office data centers are increasingly required to house such equipment, separate from general office space. The Dangers of IT Equipment Overheating System downtime due to equipment overheating can cause severe damage to a business. Electronics equipment can suffer both short-term and long-term effects from overheating. If an air-conditioning system does not keep the temperature low enough, the equipment in the data center may continue to function and show no signs of overheating, but its life cycle may be considerably shortened, adding to investment costs. In situations where the cooling capacity of the air-conditioning system is inadequate, severe overheating can quickly occur, especially if there are several or more racks of equipment, which can generate a large amount of heat. As the temperature rises to the danger level, servers, which contain a company s critical data, will usually shut themselves down to prevent possible damage or data loss. Network routers, which handle a company s internal and external data transmissions, such as e-mail and telephone communications, are even more heat-sensitive. Overheating can permanently damage them, requiring costly replacement. Potentially even more costly than equipment replacement, however, is system downtime. If a downtime occurs, all business activities and transactions supported by the electronics equipment come to a halt, sometimes with devastating results. Keeping Electronics Equipment Cool: A Historical Perspective Originally, mainframe computers, which produced very high amounts of heat, were housed in their own rooms the size of basketball courts. Huge air-conditioning systems kept the ambient temperature at a constant 55 ºF. Later, with the introduction of server technology, relatively large and sophisticated precision-cooling systems were specifically Copyright 2009 MovinCool / DENSO Sales California, Inc. 3

designed to accommodate the many dozens or even hundreds of racks of equipment contained in large, dedicated data centers. Today, the proliferation of smaller, office data centers within companies general-use, leased office space, presents new challenges for air conditioning. The Solution: Portable Spot Coolers as Permanent Air-Conditioning Systems Portable spot air conditioners are often built to be more durable than permanent units. A relatively new class of commercial portable air conditioners, called portable spot air conditioners or portable spot coolers, provides a convenient and cost-effective way of cooling office data centers. Portable spot air conditioners can be used in leased spaces, where installation of a precision-cooling system or mini-split may not be allowed. Because they are portable and are therefore designed to hold up under hard use, these units are often even more rugged than permanent systems. In fact, many portable units have been in operation for 20 years or more, with only minimal maintenance. There are two basic types of portable spot air conditioners: air-cooled and water-cooled. Although water-cooled air conditioners are more efficient than air-cooled ones, they use high-pressure water lines that can leak. Consequently, along with portable evaporative coolers, which can also leak, they are usually considered too risky to use with IT equipment. For the purposes of this paper, therefore, the terms portable air conditioner or portable spot cooler refer only to air-cooled systems. How Spot Air Conditioners Work Split air-conditioning systems consist of two separate units. One is the outdoor unit containing a compressor, condenser coil and hot-air exhaust fan. The other is the indoor unit, containing an evaporator coil and cool-air delivery fan. Spot air conditioners, on the other hand, are self-contained systems, combining a compressor, condenser coil and evaporator coil in a single unit. Within the unit, cold refrigerant flows through copper tubing from the compressor coil into the evaporator coil. A fan blows over the evaporator coil, pushing cool air out. A second fan pushes hot exhaust air out through flexible ducting, which is usually directed into the crawl space above a drop ceiling. Copyright 2009 MovinCool / DENSO Sales California, Inc. 4

Excess moisture removed from the air collects in a small condensation tank, which can be emptied manually or, with most models, automatically via a pump. Benefits of Portable Spot Air Conditioners Installation of portable spot air conditioners does not require construction, greatly reducing costs. The most important benefit of portable spot air conditioners is that they allow quick and easy installation that does not involve construction. This gives them a lower cost than other systems, and also means they do not violate most lease agreements. Installation, which does not normally require prior approval of the building owner, usually consists of no more than rolling a unit in, removing a drop-ceiling panel and positioning the exhaust duct in the space, which the panel previously occupied. Another important benefit of portable spot air conditioners is their flexibility. Whenever necessary, they can be quickly and easily moved to a different place in the data center and their airflow redirected. This is particularly helpful if any new hot spots develop, such as when equipment is added or racks are reconfigured. Also, if the business moves to a new location, unlike permanently installed air conditioners, the portable units can be taken along, eliminating the need to invest in new equipment. In addition, manufacturers offer portable spot air-conditioner models with the same type of convenience and safety features found on permanent units. These include the ability to communicate with the data center or building s monitoring and control systems, and to receive automatic safety shutoff commands from the building s fire-alarm control panel. What to Look for in a Portable Spot Air Conditioner When choosing a portable spot air conditioner, here are some important things to look for: Quality of manufacturing: Especially when critical electronics equipment is involved, an air conditioning system must be reliable. Look for equipment that is built to the highest quality standards. Specifically, check to see if the fan-motor case has ventilation holes in it. Higher-quality fan motors are made with temperature-resistant materials that eliminate the need for ventilation holes. Holes or other ventilation cutouts in the case Copyright 2009 MovinCool / DENSO Sales California, Inc. 5

Hermetically sealed refrigeration units eliminate the need to recharge the refrigerant, reducing costs. allow moisture-absorbing dust to accumulate on the motor, leading to corrosion or electrical shorts. Also, examine the casters for their durability. Are they securely attached to the frame by a mounting plate and heavy-duty bolts with welded nuts, or only by the caster stem? The stem is a weak point that can bend and cause the caster to malfunction if it goes over a rough or uneven surface. Next, look at the sheet-metal panels to see if they have stress-relief notches at the bends, to prevent possible cracks. Also, are the panels attached to the frame at load-bearing points by durable weld nuts and machine screws, or only by light sheet-metal screws, which can come loose or break? Is the weight of the fan housing supported by a sturdy, steel-frame interior panel, or only by a light cover panel, which can weaken and collapse? Another important area to pay attention to is the refrigeration unit. Is it hermetically sealed, or does it have leak-prone service valves, which make it periodically necessary to perform costly recharging? Finally, check the drain pan to see if it is fully insulated, not just powder-coated. This ensures that moisture will not come into contact with the metal surface of the pan, protecting it from corrosion and possible leaks. Such quality-oriented details are indicators of high-quality equipment that is designed and manufactured with long-term reliability in mind. Verified performance: When comparing performance specifications, check to see if the manufacturer has its equipment evaluated by a nationally recognized, independent testing laboratory such as ETL or UL, and carries a performance-verification mark. Unlike the ETL Listed or UL Listed marks, which are safety certifications, the ETL Verified mark and UL Verified marks are performance certifications. ETL Verified or UL Verified means that the equipment in question has been independently tested and found to perform at the levels the manufacturer says it will, using actual performance data, not calculated data. This type of performance verification is another indicator of high quality. Industry-standard measurements: Cooling capacity, measured in Btu/hr or tons (12,000 Btu/hr = 1 ton), is the most basic measure of an air conditioner s ability to cool a given space. Copyright 2009 MovinCool / DENSO Sales California, Inc. 6

To allow proper evaluation of cooling capacity, an industrystandard method of measuring must be used. When choosing a portable air conditioner, be sure that the manufacturer s claimed cooling capacity has been arrived at following an industry-accepted standard from the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), and not just an arbitrary one. Otherwise, the unit may provide inadequate cooling. For portable spot air conditioners, the relevant ASHRAE Standard 128-1989 specifies ambient conditions of 95 ºF at 60% RH. Unless this standard is used, the cooling capacity of the equipment in question may be much lower than what is claimed. Manufacturers of quality equipment, however, will adhere to this standard and clearly state that they have used these conditions when measuring cooling capacity. Total cost: When comparing different air-conditioning systems, as with any equipment acquisition, be sure to take into consideration the overall cost, including purchase price, installation costs, maintenance costs and estimated service life. Established manufacturer: Look for a company that has established itself for many years in the industry and stands out as a leading manufacturer of air-conditioning equipment. This is a good sign that the company will be around to support their equipment well into the future. Also, look for a company with a broad distribution base and a large number of dealers who will support and service their equipment throughout North America and globally. About MovinCool MovinCool, the world s largest manufacturer of commercial spot air conditioners, offers a complete line of portable units used in a variety of IT applications, including data centers, computer rooms and network closets. Models are available with cooling capacities as high as 60,000 Btu/h (5 tons) and in all voltage ranges. Within the air-conditioning industry, MovinCool enjoys a reputation for the highest quality and reliability. Dealers who specialize in portable spot air conditioners stand to lose considerably if they have to replace a unit once it is installed. Such dealers consistently say they prefer MovinCool spot air conditioners because of their superior reliability. MovinCool is a brand of DENSO, one of the world s largest manufacturers of automotive parts. As a principal supplier of Copyright 2009 MovinCool / DENSO Sales California, Inc. 7

advanced automotive technology, systems and components, including air conditioners, to all of the world s major car manufacturers, DENSO s commitment to quality is paramount. In the 1980s, DENSO pioneered the concept of workspace spot cooling to meet its own factory needs. Since then, MovinCool has developed a wide range of self-contained spot-cooling systems. For more information, visit MovinCool s Web site at http://www.movincool.com. Copyright 2009 MovinCool / DENSO Sales California, Inc. 8