HL7 and Meaningful Use

Similar documents
STANDARDS. MEANINGFUL USE 42 CFR 495.6(j)-(m) Stage 2 Objective Edition EHR CERTIFICATION CRITERIA 45 CFR

Eligible Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Eligible Professionals.

Stage 2 Eligible Professional Meaningful Use Core Measures Measure 15 of 17 Last Updated: August, 2015

Stage 1 vs. Stage 2 Comparison Table for Eligible Hospitals and CAHs Last Updated: August, 2012

Meaningful Use. Medicare and Medicaid EHR Incentive Programs

HL7 and Meaningful Use

Meaningful Use in 2015 and Beyond Changes for Stage 2

Stage 1 vs. Stage 2 Comparison Table for Eligible Professionals Last Updated: August, 2012

Stage 1 vs. Stage 2 Comparison for Eligible Professionals

Achieving Meaningful Use with Centricity EMR

TABLE B5: STAGE 2 OBJECTIVES AND MEASURES

EMR Name/ Model. meridianemr 4.2 CCHIT 2011 certified

TABLE 4: STAGE 2 MEANINGFUL USE OBJECTIVES AND ASSOCIATED MEASURES SORTED BY CORE AND MENU SET

EHR Incentive Programs: 2015 through 2017 (Modified Stage 2) Overview

Meaningful Use: Stage 1 and 2 Hospitals (EH) and Providers (EP) Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality

Enabling Patients Decision Making Power: A Meaningful Use Outcome. Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality

Meaningful Use Criteria for Eligible Hospitals and Eligible Professionals (EPs)

Agenda. What is Meaningful Use? Stage 2 - Meaningful Use Core Set. Stage 2 - Menu Set. Clinical Quality Measures (CQM) Clinical Considerations

Meaningful Use Updates. HIT Summit September 19, 2015

Reporting Period: For Stage 2, the reporting period must be the entire Federal Fiscal Year.

EMR Name/ Model. Cerner PowerChart Ambulatory (PowerWorks ASP)

Implementing Consolidated-Clinical Document Architecture (C-CDA) for Meaningful Use Stage 2. ONC Implementation and Testing Division April 5, 2013

MEANINGFUL USE STAGE FOR ELIGIBLE PROVIDERS USING CERTIFIED EMR TECHNOLOGY

EHR Incentive Program Stage 3 Objectives & Measures Crosswalk of Stage 3 Proposed Objectives, Measures & Corresponding Stage 2 Measures

Stage 2 Overview Tipsheet Last Updated: August, 2012

Overview of MU Stage 2 Joel White, Health IT Now

Of EHRs and Meaningful Use. Pat Wise, RN, MA, MS FHIMSS COL (USA ret d) VP, Healthcare Information Systems, HIMSS

Advancing Laboratory Interoperability in Health IT

Meaningful Use 2015 and beyond. Presented by: Anna Mrvelj EMR Training Specialist

HL7 & Meaningful Use. Charles Jaffe, MD, PhD CEO Health Level Seven International. HIMSS 11 Orlando February 23, 2011

HITECH MEANINGFUL USE

Meaningful Use Updates Stage 2 and 3. Julia Moore, Business Analyst SMC Partners, LLC July 8, 2015

Contact Information: West Texas Health Information Technology Regional Extension Center th Street MS 6232 Lubbock, Texas

HITPC Meaningful Use Stage 3 Final Recommendations

Stage 2 Meaningful Use What the Future Holds. Lindsey Wiley, MHA HIT Manager Oklahoma Foundation for Medical Quality

STAGE 2 MEANINGFUL USE CORE AND MENU MEASURES FOR ELIGIBLE PROFESSIONALS

EHR Incentive Programs for Eligible Professionals: What You Need to Know for 2015 Tipsheet

Incentives to Accelerate EHR Adoption

HIE Ready 2.0 SPECIFICATIONS MATRIX. Product Name: Version Number: Preferred Message and Trigger

APPENDIX A: OBJECTIVES AND MEASURES FOR 2015 THROUGH 2017 (MODIFIED STAGE 2) EP Objectives and Measures

Eligible Professional EHR Incentive Program Objectives and Measures for 2016 Objective 10 of 10 Date updated: February 4, 2016

Meaningful Use Objectives

Work Product of the HITPC Meaningful Use Workgroup Meaningful Use Stage 3 Recommendations

Summary of Public Health Related Aspects of Recent ONC and CMS Final Rules Version 1.0

Presented by. Terri Gonzalez Director of Practice Improvement North Carolina Medical Society

hospital s or CAH s inpatient or professional guidelines

Meaningful Use Stage 1:

Stage 2 Final Rule Overview: Updates to Stage 1 and New Stage 2 Requirements

STAGES 1 AND 2 REQUIREMENTS FOR MEETING MEANINGFUL USE OF EHRs 1

Meaningful Use Stage 2

Meaningful Use Final Rule Update. Patti Kritzberger, RHIT, CHPS Tracey Regimbal, RHIT HIT-Quality Improvement Specialists

MEANINGFUL USE. Community Center Readiness Guide Additional Resource #13 Meaningful Use Implementation Tracking Tool (Template) CONTENTS:

HIMSS Interoperability Showcase 2011

Work Product of the HITPC Meaningful Use Workgroup DRAFT Meaningful Use Stage 3 Recommendations

Stage 1 measures. The EP/eligible hospital has enabled this functionality

MEETING MEANINGFUL USE IN MICROMD -STAGE TWO- Presented by: Anna Mrvelj EMR Training Specialist

AAP Meaningful Use: Certified EHR Technology Criteria

MEANINGFUL USE STAGE 2 REQUIREMENTS FOR ELIGIBLE PROVIDERS USING CERTIFIED EMR TECHNOLOGY

The value MIE delivers can be summed up in two words:

Webinar #1 Meaningful Use: Stage 1 & 2 Comparison CPS 12 & UDS 2013

Meaningful Use Stage 2 Certification: A Guide for EHR Product Managers

Certification Guidance for EHR Technology Developers Serving Health Care Providers Ineligible for Medicare and Medicaid EHR Incentive Payments

Summary of the Proposed Rule for the Medicare and Medicaid Electronic Health Records (EHR) Incentive Program (Eligible Professionals only)

Meaningful Use Stage 2. Presenter: Linda Wise, EMR Training Specialist

Understanding Meaningful Use Stage 2

STAGE 2 of the EHR Incentive Programs

The Future of Meaningful Use

Meaningful Use of Certified EHR Technology with My Vision Express*

Meaningful Use Cheat Sheet CORE MEASURES: ALL REQUIRED # Measure Exclusions How to Meet in WEBeDoctor

THE STIMULUS AND STANDARDS. John D. Halamka MD

Meaningful Use Rules Proposed for Electronic Health Record Incentives Under HITECH Act By: Cherilyn G. Murer, JD, CRA

IMS Meaningful Use Webinar

REQUIREMENTS GUIDE: How to Qualify for EHR Stimulus Funds under ARRA

SUMMARY. Centers for Medicare and Medicaid Services Medicare and Medicaid Electronic Health Record Incentive Programs Stage 2 Final Rule CMS-0044-F

HIMSS Interoperability Showcase 2011

Medicaid EHR Incentive Program. Focus on Stage 2. Kim Davis-Allen, Outreach Coordinator

Core Set of Objectives and Measures Must Meet All 15 Measures Stage 1 Objectives Stage 1 Measures Reporting Method

Understanding Meaningful Use with a Focus on Testing the HL7 V2 Messaging Standards

Stage 2 of Meaningful Use: Ten Points of Interest

Navigating the Trends in Health Care Today. MEDITECH Solutions for Meaningful Use and Interoperability

Meaningful Use Stage 2 MU Audits

MDeverywhere, Inc. Presents 2014 CMS EHR Incentive Program Requirements: What Providers Need To Know

HealthFusion MediTouch EHR Stage 2 Proposed Rule Comments

Health Information Exchange. Scalable and Affordable

Adopting an EHR & Meaningful Use

Meaningful Use Stage 2: Important Implications for Pediatrics

Transcription:

HL7 and Meaningful Use Grant M. Wood HL7 Ambassador HIMSS14 2012 Health Level Seven International. All Rights Reserved. HL7 and Health Level Seven are registered trademarks of Health Level Seven International. Reg. U.S. TM Office.

Many Types of Healthcare Information Need to be Exchanged Pharmacy Medication Lists Government Agencies, Public Health, Research Lab Test Results Hospitalization Summaries Payers / Financial Systems Patient Home Health Monitoring Devices Medical Imaging Results Doctors Orders and Clinicians Notes

Need For Integrated Systems Doctors need to be connected with each other especially during transfer of care

Need For Integrated Systems Hospitals need to be connected with each other especially for medical record transfer

Need For Integrated Systems Laboratories need to be connected to the patient s electronic health record

Need For Integrated Systems Doctors need to be connected to the patient s personal health record

Healthcare IT Stakeholders Patients Consumers General Practitioners Specialists Outpatient Healthcare Providers Residential Care Providers Hospitals Healthcare Administration Pharmaceutical Payers, Insurance Employers Medical Equipment Review Boards Practice Guidelines Government Agencies Standards Enforcement Agencies

HL7 Mission - Interoperability Goals HL7's mission is to provide standards for interoperability that: optimize workflow reduce ambiguity enhance knowledge transfer improve care delivery

Healthcare Standards Improve Patient Care Empower patient to manage their own health Improve public health reporting Improve quality of care Benefits of Standards: Supports lifetime electronic health record Electronic documents provide value to clinicians increase efficiency, improve quality, lower cost, and reduce risk Eliminate duplicate medical tests Ensure clinicians have latest knowledge Improve patient safety/ Minimize preventable errors Lower cost of healthcare delivery Improve clinical workflow

Domains Covered in HL7 Standards Accounting & Billing Claims & Reimbursement Materials Management Patient Administration Personnel Management Scheduling Biorepositories Care Provision Clinical Decision Support Patient Documentation Clinical Genomics Diagnostic Imaging Nursing Immunization Laboratory Medical Records Medication Physician Order Entry Pharmacy Primary Care Public Health Regulated Products Regulated Studies Specialty Care Therapeutic Devices Mobile Health

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Interoperability Between Hospital-Based Outpatient Clinicians and External Laboratories Annual savings of $31.8 billion at highest level of interoperability. In addition to reducing duplicate tests, it would 1) reduce delays and costs associated with paper-based ordering and reporting of results, 2) provider-laboratory connectivity would give clinicians better access to patients longitudinal test results, 3) eliminate errors associated with reporting results orally, 4) optimize ordering patterns by making information on test costs readily available to clinicians, and 5) make testing more convenient for patients. Walker, et al. The Value Of Health Care Information Exchange And Interoperability Health Affairs Web Exclusive, January 19, 2005

Connectivity Between Office-Based Clinicians and External Radiology Centers Annual savings of $26.2 billion at highest level of interoperability. In addition to reducing duplicate tests, it would 1) save time and costs associated with paper- and film-based processes, 2) improve ordering by giving radiologists access to relevant clinical information, thereby enabling them to recommend optimal testing, 3) improve patient safety by alerting both the provider and the radiologist to test contraindications, 4) facilitate coordination of care and help prevent errors of omission by enabling automated reminders when follow-up studies are indicated, and 5) lessen adverse environmental impacts by reducing the use of chemicals and paper in film processing. Walker, et al. The Value Of Health Care Information Exchange And Interoperability Health Affairs Web Exclusive, January 19, 2005

Interoperability Between Outpatient Providers and Pharmacies Annual savings of $ 2.71 billion at highest level of interoperability. In addition to reducing the number of medication-related phone calls for both clinicians and pharmacists, it would 1) improve clinical care by facilitating the formation of complete medication lists, thereby reducing duplicate therapy, drug interactions and other adverse drug events, and medication abuse, 2) enable automated refill alerts, 3) offer clinicians easy access to information about whether patients fill prescriptions, 4) complete insurance forms required for some medications, 5) help identify affected patients in the event of drug recalls, uncover new side effects, and improve formulary management. Walker, et al. The Value Of Health Care Information Exchange And Interoperability Health Affairs Web Exclusive, January 19, 2005

Provider to Provider Connectivity Annual savings of $13.2 billion at highest level of interoperability. In addition to saving time associated with handling chart requests and referrals it would 1) would reduce fragmentation of care from scattered records and improve referral processes. Walker, et al. The Value Of Health Care Information Exchange And Interoperability Health Affairs Web Exclusive, January 19, 2005

Use Case Medium-Size Hospital The hospital (with 50 199 beds) would invest $2.7 million in clinical systems and interfaces to achieve the highest level of interoperability. After the first year, spending $250,000 per year to maintain those systems it would accrue benefits of $1.3 million annually, from 1) its transactions with other providers ($570,000), 2) laboratories ($200,000), 3) radiology centers ($170,000), 4) payers ($250,000), and 5) pharmacies ($70,000). Walker, et al. The Value Of Health Care Information Exchange And Interoperability Health Affairs Web Exclusive, January 19, 2005

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

CDA is the Basis For... Continuity of Care Document Consult Note Diagnostic Imaging Report Discharge Summary Healthcare-associated Infections, Public Health Case Reports History and Physical Operative Note Personal Health Monitoring Plan-2-Plan Personal Health Record Quality Reporting Document Unstructured Documents Emergency Care Summary Summary Documents Using HL7 CCD Patient Level Quality Data Document Using IHE Medical Summary (XDS-MS) Encounter Document constructs Consult and History & Physical Note Document Immunization Document Scanned document and many more

Clinical Document Architecture (CDA) Interoperability An approved standard way to exchange dictated, scanned, or electronic reports on a patient between various health information technology systems and platforms Human readable The paper world of clinical documents, forms, etc. Computer readable XML representation of document data EHR discrete data storage Clinical decision support

What is a Continuity of Care Document? A medical summary representing the continuity of care record core data set covering one or more healthcare encounters. A snapshot in time for a patient, in CDA form, containing the pertinent: clinical, demographic, and administrative data

CCD Required Sections Conditions (Problems) active resolved chief complaint reason for visit diagnoses admission discharge pre-operative post-operative Allergies and Intolerances pharmacy dietary general Medications history administered discharge current

CCD Optional Sections Advanced Directives Functional Status Procedures Encounters Family History Social History Immunizations Vital Signs Fetal Vital Signs Lab Results Plan of Care

Consolidated CDA The development of a single implementation guide that represents harmonization of Health Story guides, HITSP C32, part of the IHE Patient Care Coordination, and the original CCD by HL7 9 different types of commonly used CDA documents Continuity of Care Document Consultation Notes Discharge Summary Imaging Integration, and DICOM Diagnostic Imaging Reports History and Physical Operative Note Progress Note Procedure Note Unstructured Documents

Consolidated CDA Stage 2 Measure The EP, EH, or CAH that transitions or refers their patient to another setting of care or provider of care provides a summary of care record for more than 50% of transitions of care and referrals. More than 50% of all unique patients seen by the EP during the EHR reporting period are provided timely (within 4 business days after the information is available to the EP) online access to their health information subject to the EP's discretion to withhold certain information.

Consolidated CDA - Certification Criteria Display. EHR technology must be able to electronically display in human readable format the data included in transition of care/referral summaries received and formatted according to any of the following standards (and applicable implementation specifications) specified in: 170.205(a)(1), 170.205(a)(2), and 170.205(a)(3).

Consolidated CDA - Standards 170.205(a)(1) HL7 CDA Release 2, CCD. Implementation specifications: HITSP Summary Documents Using HL7 CCD Component HITSP/C32 170.205(a)(2) ASTM E2369 Standard Specification for Continuity of Care Record and Adjunct to ASTM E2369 170.205(a)(3) HL7 Implementation Guide for CDA Release 2: IHE Health Story Consolidation.

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Lab Result Interface - Stage 2 Measure More than 55 % of all clinical lab tests results ordered by the EP or by authorized providers of the EH or CAH for patients admitted to its inpatient or emergency department (POS 21 or 23) during the EHR reporting period whose results are either in a positive/negative affirmation or numerical format are incorporated in CEHRT as structured data. Hospital labs send structured electronic clinical lab results to the ordering provider for more than 20% of electronic lab orders received.

Lab Result Interface - Certification Criteria Incorporate laboratory tests and values/results. (i) Receive results. (A) Ambulatory setting only. (1) Electronically receive and incorporate clinical laboratory tests and values/results in accordance with the standard specified in 170.205(j) and, at a minimum, the version of the standard specified in 170.207(c)(2). Inpatient setting only transmission of electronic laboratory tests and values/results to ambulatory providers. EHR technology must be able to electronically create laboratory test reports for electronic transmission in accordance with the standard specified in 170.205(j) and with laboratory tests expressed in accordance with, at a minimum, the version of the standard specified in 170.207(c)(2)

Lab Result Interface - Standards 170.205(j) HL7 Version 2.5.1. Implementation Guide: S&I Framework Lab Results Interface 170.207(c)(2) LOINC version 2.40, June 2012, a universal code system for identifying laboratory and clinical observations produced by the Regenstrief Institute

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Immunization Stage 2 Measure The EP, EH, or CAH who transitions their patient to another setting of care or provider of care or refers their patient to another provider of care provides a summary care record for each transition of care or referral. Successful ongoing submission of electronic immunization data from CEHRT to an immunization registry or immunization information system for the entire reporting period.

Immunization Certification Criteria Transitions of care: (b)(2) create and transmit transition of care/referral summaries. (i) Create. Enable a user to electronically create a transition of care/referral summary formatted according to the standard adopted at 170.205(a)(3) that includes, at a minimum, the Common MU Data Set** and the following data expressed, where applicable, according to the specified standard(s): (B) Immunizations. The standard specified in 170.207(e)(2); Immunization information. Enable a user to electronically record, change, and access immunization information. Transmission to immunization registries. EHR technology must be able to electronically create immunization information for electronic transmission in accordance with: (i) The standard and applicable implementation specifications specified in 170.205(e)(3); and (ii) At a minimum, the version of the standard specified in 170.207(e)(2).

Immunization Messaging - Standards 170.207(e)(2) HL7 Standard Code Set CVX Vaccines Administered, updates through July 11, 2012 170.205(e)(3) HL7 2.5.1. Implementation specifications: Hl7 2.5.1 Implementation Guide for Immunization Messaging, Release 1.4

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Lab Reporting to Public Health Stage 2 Measure Successful ongoing submission of electronic syndromic surveillance data from CEHRT to a public health agency for the entire EHR reporting period.

Transmission to public health agencies syndromic surveillance. EHR technology must be able to electronically create syndrome-based public health surveillance information for electronic transmission in accordance with: (i) Ambulatory setting only. (A) The standard specified in 170.205(d)(2). (B) Optional. The standard (and applicable implementation specifications) specified in 170.205(d)(3). (ii) Inpatient setting only. The standard (and applicable implantation specifications) specified in 170.205(d)(3). Inpatient setting only transmission of reportable laboratory tests and values/results. EHR technology must be able to electronically create reportable laboratory tests and values/results for electronic transmission in accordance with: Lab Reporting to Public Health Certification Criteria (i) The standard (and applicable implementation specifications) specified in 170.205(g); and (ii) At a minimum, the versions of the standards specified in 170.207(a)(3) and (c)(2).

Lab Reporting to Public Health Standards 170.205(g) HL7 2.5.1. Implementation specifications: HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1 (US Realm) with Errata and Clarifications, and ELR 2.5.1 Clarification Document for EHR Technology Certification.

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Using Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Clinical Decision Support Stage 2 Measure Implement five clinical decision support interventions related to four or more clinical quality measures at a relevant point in patient care for the entire EHR reporting period.

Clinical Decision Support - Certification Criteria (ii) Linked referential clinical decision support. (A) EHR technology must be able to: (1) Electronically identify for a user diagnostic and therapeutic reference information; or (2) Electronically identify for a user diagnostic and therapeutic reference information in accordance with the standard specified at 170.204(b) and the implementation specifications at 170.204 (b)(1) or (2).

Clinical Decision Support - Standards 170.204(b) HL7 V3 Standard: Context-Aware Retrieval Application (Infobutton). Implementation specifications: 170.204(b)(1) HL7 V3 IG: URL-Based Implementations of Context-Aware Information Retrieval (Infobutton) Domain; or 170.204(b)(2) HL7 V3 IG: Context-Aware Knowledge Retrieval (Infobutton) Service-Oriented Architecture Implementation Guide.

HL7 Meaningful Use Standards Consolidated CDA S&I Framework Laboratory Result Interface Immunization Messaging Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Family Health History Quality Reporting Document Architecture

Family Health History Stage 2 Measure More than 20% of all unique patients seen by the EP or admitted to the EH s or CAH's inpatient or emergency department (POS 21 or 23) during the EHR reporting period have a structured data entry for one or more firstdegree relatives.

Family Health History - Certification Criteria Enable a user to electronically record, change, and access a patient s family health history according to: (i) At a minimum, the version of the standard specified in 170.207(a)(3); or (ii) The standard specified in 170.207(j)

Family Health History - Standards 170.207(j) HL7 Version 3 Standard: Clinical Genomics; Pedigree. HL7 Version 3 Implementation Guide: Family History/Pedigree Interoperability, Release 1 January 2013

HL7 Meaningful Use Standards Consolidated CDA Family Health History S&I Framework Laboratory Result Interface Immunization Messaging Using Electronic Laboratory Reporting to Public Health Infobuttons for Clinical Decision Support Quality Reporting Document Architecture

Quality Reporting Stage 2 Measure In the 2014 Edition EHR certification criteria final rule, we adopted the QRDA III, Release 1, standard at 45 CFR 170.205(k) and incorporated the standard by reference at 45 CFR 170.299(f)(14). The QRDA III is included in the certification criterion at 45 CFR 170.314(c)(3), which requires EHR technology presented for certification to be capable of electronically creating a data file for transmission of clinical quality measurement data in accordance with QRDA III and that can be electronically accepted by CMS.

Quality Reporting Certification Criteria EPs, EHs, and CAHs will electronically report their CQMs in the QRDA Category I format, which will be the basis for EHR-based reporting. They may also submit aggregate-level data in QRDA III format. EPs must report on 9 of the 64 approved CQMs Eligible Hospitals and CAHs must report on 16 of the 29 approved CQMs

Quality Reporting Standards HL7 Implementation Guide for CDA Release 2: Quality Reporting Document Architecture - Category III, DSTU Release 1 (US Realm) Draft Standard for Trial Use, November 2012

Global Topics Covered in Training 1. Need To Send/Receive Which Artifact Exactly when are EHRs supposed to send this information? 2. A Valid Example of What You Are Expected To Send Or Receive And Its Description Each section will walk-through an example artifact identifying its different parts and the content inside 3. How to Read and Understand the Meaningful Use Stage 2 Implementation Guides Go through the implementation guides that define the required artifacts and their major parts and constraints 4. The Vocabularies Needed Brief discussion will cover CVX, LOINC, SNOMED, etc. 5. Which HL7 Standards Do You Need To Know Brief discussion on the standards and how to learn more about them

HL7 High Level Goals Stimulate, encourage and facilitate domain experts from healthcare industry stakeholder organizations to participate in HL7 to develop healthcare information standards in their area of expertise Collaborate with healthcare information technology users to ensure that HL7 standards meet real-world requirements, and that appropriate standards development efforts are initiated by HL7 to meet emergent requirements

Standards Drive Increased Business for Healthcare IT Vendors and Service Providers Speed of development, faster time to market Lower development & installation costs, over customized interfaces Clients prefer the flexibility of products with standardized interfaces Enhanced interoperability of product Standards create best practices for the international community Bigger market beyond that for proprietary products More scalable solution

Working Group Meetings

Education Portal

New Member Benefits

HL7 and Meaningful Use QUESTIONS 2012 Health Level Seven International. All Rights Reserved. HL7 and Health Level Seven are registered trademarks of Health Level Seven International. Reg. U.S. TM Office.