Attaching the PA-A1-ATM Interface Cables



Similar documents
Cabling & Test Considerations for 10 Gigabit Ethernet LAN

HP ProCurve High-Speed Transceivers Installation Guide

The Conversion Technology Experts. Fiber Optics Basics

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

CISCO 10GBASE X2 MODULES

Designing Fiber Optic Systems David Strachan

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Cisco SFP Optics for Gigabit Ethernet Applications

Fibre Channel Fiber Cabling

SFP Transceiver Specifications

With the advent of Gigabit Ethernet

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

The following terms are defined within the context of the fiber optic industry

How To Get A Better Signal From A Fiber To A Coax Cable

Overcoming OM3 Performance Challenges

Measuring of optical output and attenuation

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

QuickSpecs. Models HP X131 10G X2 CX4 Transceiver. HP X131 10G X2 Transceivers (SR, LRM, LR, ER and CX4) Overview. HP X131 10G X2 SC LRM Transceiver

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

Wavelength Division Multiplexing

Simulation and Best Design of an Optical Single Channel in Optical Communication Network

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Optical Communications Analysis of transmission systems. Henrique Salgado Point-to-point system

QuickSpecs. Models HP X132 10G SFP+ LC ER Transceiver. HP SFP+ Transceivers (SR, LRM, LR and ER) Overview

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

FIBER OPTIC SYSTEM TEST PROCEDURES

Gigabit Switching Ethernet Media Converters - Product User Guide

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Fiber Distributed Data Interface

QuickSpecs. Models. ProCurve Mini-GBICs Overview. ProCurve Gigabit-LX-LC Mini-GBIC. ProCurve Gigabit-LH-LC Mini-GBIC

Laser-Optimized Fiber

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

Network Design. Yiannos Mylonas

Cisco 10GBASE SFP+ Modules

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Guide to Industrial Fiber Optics

Preparing Infrastructure for 10 Gigabit Ethernet Applications

Field Measurements of Deployed Fiber

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Installation Guide for GigaBit Fiber Media Converter

Module 13 : Measurements on Fiber Optic Systems

EECC694 - Shaaban. Transmission Channel

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Fiber Optics: Engineering from Global to Nanometer Dimensions

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

What are Fibre Optics?

INTRODUCTION TO MEDIA CONVERSION

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Create. Monitor. Reconfigure. Switching RF Over Fiber. Case Study. The Problem.

Network Topologies and Distances

Gigabit Ethernet: Architectural Design and Issues

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Dispersion penalty test 1550 Serial

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Cisco ONS Multiservice Transport Platform 7.0

Fiber Selection and Standards Guide for Premises Networks

FIBER OPTIC COMMUNICATIONS. Optical Fibers

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Basics of Fiber Optics Mark Curran/Brian Shirk

Fiber optic telecommunications technology and systems A Two-course sequence for a telecommunications engineering technology MS program

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Upgrading Path to High Speed Fiber Optic Networks

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Gigabit Ethernet Copper-to-Fiber Converters

1.264 Lecture 32. Telecom: Basic technology. Next class: Green chapter 4, 6, 7, 10. Exercise due before class

Security & Surveillance Cabling Systems

Fibre Channel Fiber-to-Fiber Media Converters

Your Network. Our Connection. 10 Gigabit Ethernet

WHITE PAPER. 50 versus 62.5 micron multimode fiber

Simulation of Gaussian Pulses Propagation Through Single Mode Optical Fiber Using MATLAB . MATLAB

Recession-Proof Consulting Services with CWDM Network Design

Tools for Building a Better Network

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Data Center Design for 40/100G

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

How To Use A Network Instrument Ntap

Transcription:

CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms. This chapter contains the following sections: Connecting an Interface Cable, page 4-1 SONET Distance Limitations, page 4-2 Determining the Power Budget, page 4-3 Approximating the PA-A1-ATM Power Margin, page 4-3 Connecting an Interface Cable PA-A1-ATM interfaces are full-duplex. You must use the appropriate ATM interface cable to connect the PA-A1-ATM with an external ATM network. The PA-A1-ATM, shown in Figure 4-1 and Figure 4-2, provides an interface to ATM switching fabrics for transmitting and receiving data at rates of up to 155 Mbps bidirectionally. The PA-A1-ATM connects to the SONET/SDH 155 Mbps multimode or single-mode optical fiber STS-3 or STM-1 physical layer. An OC-3 ATM interface cable, which is used to connect your router to an external DSU (an ATM network), is available for use with the PA-A1-ATM. Note The ATM port on the PA-A1-ATM is considered to be a DTE device. Cables can be obtained from the following cable vendors: AT&T Siecor Siemens Red-Hawk Anixter AMP For SONET/SDH multimode and SONET/STC-3 single-mode connections, use one duplex SC connector (see Figure 4-1) or two single SC connectors (see Figure 4-2). The SONET simplex and duplex SC connectors are shipped with removable dust covers on each connector. Attaching the PA-A1-ATM Interface Cables 4-1

SONET Distance Limitations Figure 4-1 Duplex SC Connector Figure 4-2 Simplex SC Connector H2399 H2214 Single-mode and multimode cables should perform to the following specifications: Standard Maximum Path Length Cabling ISO/IEC 9314-3 2 km (all cables in a 62.5-micron core with an optical loss of 0-9 db, or connection, end-to-end) 50-micron core with an optical loss of 7 db Note A single fiber link should not mix 62.5- and 50-micron cable. SONET Distance Limitations The SONET specification for fiber-optic transmission defines two types of fiber: single-mode and multimode. Modes can be thought of as bundles of light rays entering the fiber at a particular angle. Single-mode fiber allows only one mode of light to propagate through the fiber, while multimode fiber allows multiple modes of light to propagate through the fiber. Multiple modes of light propagating through the fiber travel different distances depending on the entry angles. The differing travel speeds cause the modes to arrive at the destination at different times. Single-mode fiber is capable of higher bandwidth and greater cable run distances than multimode fiber. The typical maximum distances for single-mode and multimode transmissions, as defined by SONET, are in Table 4-1. If the distance between two connected stations is greater than this maximum distance, significant signal loss can result, making transmission unreliable. 4-2 PA-A1 ATM Port Adapter Installation and Configuration

Determining the Power Budget Table 4-1 Maximum Fiber-Optic Power Budget and Transmission Distances Transceiver Type Single-mode 2 Power Budget Transmit Power Receive Power 13 db 15 to 8 dbm at 1261 to 1360 nm 3 Multimode 11 db 19 to 14 dbm at 1270 to 1380 nm Maximum Distance between Stations 1 28 to 8 dbm Up to 9.3 miles (15 km) 30 to 14 dbm Up to 1.2 miles (2 km) 1 Table 4-1 gives typical results. Use the power budget calculations described below to determine the actual distances. 2 Complies with Bellcore GR-253 Intermediate Reach Specification. 3 nm = nanometers Determining the Power Budget To design an efficient optical data link, evaluate the power budget. The power budget is the amount of light available to overcome attenuation in the optical link and to exceed the minimum power that the receiver requires to operate within its specifications. Proper operation of an optical data link depends on modulated light reaching the receiver with enough power to be correctly demodulated. Attenuation, caused by the passive media components (cables, cable splices, and connectors), is common to both multimode and single-mode transmission. The following variables reduce the power of the signal (light) transmitted to the receiver in multimode transmission: Chromatic dispersion (spreading of the signal in time because of the different speeds of light wavelengths) Modal dispersion (spreading of the signal in time because of the different propagation modes in the fiber) Attenuation is significantly lower for optical fiber than for other media. For multimode transmission, chromatic and modal dispersion reduce the available power of the system by the combined dispersion penalty (db). The power lost over the data link is the sum of the component, dispersion, and modal losses. Table 4-2 lists the factors of attenuation and dispersion for typical fiber-optic cable. Table 4-2 Typical Fiber-Optic Link Attenuation and Dispersion Limits Limits Single-mode Multimode Attenuation 0.5 db 1.0 db/km Dispersion No limit 500 MHz/km 1 1 The product of bandwidth and distance must be less than 500 MHz/km. Approximating the PA-A1-ATM Power Margin The LED used for a multimode transmission light source creates multiple propagation paths of light, each with a different path length and time requirement to cross the optical fiber, causing signal dispersion (smear). Higher order mode loss (HOL) results when light from the LED enters the fiber and radiates into the fiber cladding. A worst case estimate of power margin (PM) for multimode transmissions assumes minimum transmitter power (PT), maximum link loss (LL), and minimum receiver sensitivity (PR). The worst case analysis provides a margin of error; not all of the parts of an actual system will operate at the worst case levels. Attaching the PA-A1-ATM Interface Cables 4-3

Approximating the PA-A1-ATM Power Margin The power budget (PB) is the maximum possible amount of power transmitted. The following equation lists the calculation of the power budget: PB = PT PR PB = 20 decibels per meter (dbm) ( 30 dbm) PB = 10 db The power margin calculation is derived from the power budget and subtracts the link loss, as follows: PM = PB LL If the power margin is positive the link usually will work. Table 4-3 lists the factors that contribute to link loss and the estimate of the link loss value attributable to those factors. Table 4-3 Link Loss Factors and Values Link Loss Factor Higher order mode losses Clock recovery module Modal and chromatic dispersion Connector Splice Fiber attenuation Estimate of Link Loss Value 0.5 db 1 db Dependent on fiber and wavelength used 0.5 db 0.5 db 1 db/km for multimode (0 db/km for single-mode) After calculating the power budget minus the data link loss, the result should be greater than zero. Circuits whose results are less than zero may have insufficient power to operate the receiver. The SONET specification requires that the signal must meet the worst case parameters listed in Table 4-4. Table 4-4 ATM Port Adapter SONET Signal Requirements Single-mode Multimode PT 15 dbm 20 dbm PR 31 dbm 30 dbm PB 13 db 11 db Multimode Power Budget Example with Sufficient Power for Transmission The following is an example of multimode power budget calculated based on the following variables: Length of multimode link = 3 kilometers (km) 4 connectors 3 splices Higher order loss (HOL) Clock recovery module (CRM) 4-4 PA-A1 ATM Port Adapter Installation and Configuration

Multimode Power Budget Example of Dispersion Limit Estimate the power budget as follows: PB = 11 db 3 km (1.0 db/km) 4 (0.5 db) 3 (0.5 db) 0.5 db (HOL) 1 db (CRM) PB = 11 db 3 db 2 db 1.5 db 0.5 db 1 db PB = 3 db The positive value of 3 db indicates that this link would have sufficient power for transmission. Multimode Power Budget Example of Dispersion Limit The following example has the same parameters as the previous example, but with a multimode link distance of 4 km: PB = 11 db 4 km (1.0 db/km) 4 (0.5 db) 3 (0.5 db) 0.5 db (HOL) 1 db (CRM) PB = 11 db 4 db 2 db 1.5 db 0.5 db 1 db PB = 2 db The value of 2 db indicates that this link would have sufficient power for transmission. But, because of the dispersion limit on the link (4 km x 155.52 MHz > 500 MHz/km), this link would not work with multimode fiber. In this case, single-mode fiber would be the better choice. Single-Mode Transmission The single-mode signal source is an injection laser diode. Single-mode transmission is useful for longer distances, because there is a single transmission path within the fiber and smear does not occur. In addition, chromatic dispersion is also reduced because laser light is essentially monochromatic. The maximum overload specification on the single-mode receiver is 14 dbm. The single-mode receiver can be overloaded when using short lengths of fiber because the transmitter can transmit up to 8 db, but no damage to the receiver will result. To prevent overloading the receiver that is connecting short fiber links, insert a 5 to 10 db attenuator on the link between any single-mode SONET transmitter and the receiver. SONET Single-Mode Power Budget Example The following example of a single-mode power budget assumes two buildings, 8 kilometers apart, are connected through a patch panel in an intervening building with a total of 12 connectors. Length of single-mode link = 8 km 12 connectors Estimate the power budget as follows: PM = PB LL PM = 13 db 8 km (0.5 db/km) 12 (0.5 db) PM = 13 db 4 db 6 db PM = 3 db The value of 3 db indicates that this link would have sufficient power for transmission and is not in excess of the maximum receiver input power. Attaching the PA-A1-ATM Interface Cables 4-5

Approximating the PA-A1-ATM Power Margin Using Statistics to Estimate the Power Budget Statistical models more accurately determine the power budget than the worst case method. Determining the link loss with statistical methods requires accurate knowledge of variations in the data-link components. Statistical power budget analysis is beyond the scope of this document. For further information, refer to UNI Forum specifications, ITU-T standards, and your equipment specifications. 4-6 PA-A1 ATM Port Adapter Installation and Configuration

Using Statistics to Estimate the Power Budget Attaching the PA-A1-ATM Interface Cables 4-7