lnstallatlllil N~IOE lnstructions El



Similar documents
LED Indication of Zone Status, A.C. Power and Alarm Memory (indicates alarm has taken place and bel I has timed off).

SECTION DETECTION AND ALARM

Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: 1. _- ALARM DEVICE MANUFACTURING CO.

Control/Communicator Installation Manual

Using your LED Plus keypad

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Reference & Installation Manual

GE Concord 4 Quick User Guide

INSTALLATION MANUAL PC2525. Version 1.1

ACTIVE 5 ENGINEERING MANUAL

INSTRUCTION MANUAL PC255O

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

SECURITY SYSTEM NOTES

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

1R / 4-BUTTON SERIES

User's Manual 5120XM N8031 6/96

TABLE OF CONTENTS FEATURES

P/N Rev D

SECURITY SYSTEM NOTES

NetworX NX-6V2. LED Keypad User Manual

SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

500r+ Installation and User Guide

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

AM100 SECURITY SYSTEM INSTALLATION INSTRUCTIONS

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Users Guide to Keypad Functions

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

Contact ID Event Definition Codes

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

ACP10 10 Zone Intruder Alarm System

Simon XTi Installation Guide

National Security Systems Inc (800) Security System User's Guide

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

First Alert FA140C/142C Installer Notes M. Leuck

NESS D Zone Control Panel and Dialler OWNER S MANUAL

SECURITY SYSTEM NOTES. Security System Configuration

CONTENTS 4. HOW TO UNSET THE PANEL...7

SPECIFICATIONS. Remote Keypad Specifications (PC2550RK) Output Voltage Specification. Digital Communicator Specifications

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

DC-8706K Auto Dial Alarm System

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

TS510 & TS500. Installation & User Guide. Compatible Equipment

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power

9452/9453 Installation and User Guide

HM-W536 Install Guide

VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling

6HFXULW\6\VWHPV 8VHU V*XLGH K5309-1V1 8/01

D287/D288/D292/D293A/D293E

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM

PERS-2400B PERSONAL EMERGENCY REPORTING SYSTEM. Installation, and Operation Instructions

Expansion Modules & Accessories

Destiny Destiny Owners Manual

How To Compare An Xl1S To An Xli2

Contact ID as of 2/2/2015

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Fire Alarm Control Panel. Family. Operating Manual

IDS X-Series User Manual D Issued July 2012

Security Systems Intrusion Alarm

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

WIRELESS HOME ALARM SYSTEM (WHA1)

VISTA-100. Commercial Fire and Burglary 8VHU*XLGH. Partitioned Security System. N Rev B 4/99 FIRE FIRE PULL

8VHU V*XLGH 6HFXULW\6\VWHPV (QWUHSUHQHXU(1 6HFXULW\0DQDJHU(1. Meets ADT Security Services Triple Standards Requirements:

INTRODUCTION TO THE OMNI SECURITY SYSTEM THE HEART OF YOUR SECURITY SYSTEM IS THE OMNI 1000 CONTROL PANEL

SILENT KNIGHT MODEL 5207

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

ICP-CC488. Installation Guide ICP-CC488 Control Panel

GC2 Panel User Guide

Digital Keypad Use s Manual

Microprocessor Home Security System

NetworX Series. NX-148E LCD Keypad. User Manual

Security System. User's Guide. Keypad

User Guide for the DS7060 Control/Communicator

NetworX NX-8 Control/Communicator Installation Manual

616, 626, 636 & 646 Keypads

Business/ Home GSM Alarm System

Wireless Alarm system s manual

Section 1: About Your ORBIT-Pro

FIREDEX Conventional Fire Panels

User s Information Guide R1A

PLAN REVIEW GUIDE FOR FIRE ALARM

DESTINY 1/19/96 # A

MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40. Reference & Installation

D1260/D1260B. Keypad. National Security Systems Inc (800) Owner's Manual

Keys to understanding your alarm system

Transcription:

FADEMCO~ lnstallatlllil N~OE lnstructons El ALARM PROCESSNG CENTER :p _ GENERAL NFORMATON: The No. 1025 Alarm Processing Center is a local alarm panel with the following features: Basic Supervised Protection Zone for Normal and Fast Acting Perimeter and nterior Devices. Entry/Exit Zone with 45 (or 30) Second Entry and Exit Delay Times. Supervised. 24 Hour Audible Emergency (Panic) Circuit, LED ndication of Zone Status, A.C. Power and Alarm Memory (indicates alarm has taken place and bell has timed off). Outputs for Bell(s) or Electronic Siren(s), Closure of Dry Contacts, and (Optional) Early Warning Horn. Automatic Alarm Cut-off and Restore. Bell and Battery Test Switch. ncludes Low Voftage Plug-in Transformer and Built-in Rechargeable Power Supply. System Turned ON and OFF from a Keyswitch (e.g.: No. 4235). Remote Station(s) may be used instead (see ACCES- SORES at end of these instructions). The cabinet provides room for optional installation of a digital communicator (e.g.: No. WS669, WS670,678,679 680) or other accessories (see ACCESSORES herein). NSTALLATON AND WRNG: See Figure 1 Do not connect thebattery or plug-in transformer until all other wiring has been completed. Use of twisted wiring is recommended for all runs, for greater immunity to unwanted induced voltage. A WHTE jumper is provided at the top of the chassis. f this jumper is cut it will shorten the factory provided entry delay, exit delay and bell cut-off times as tabulated in Figure 1. Terminals Wiring nformation 123.4 Basic Protection Zone (Double Loop): Run a pair of wires from terminals 1 and 2 to all protection points in this zone and return to terminals 4 and 3 respectively. Connect protection devices into the two loops as follows: 2.3 Normal Response Loop (Basic Protection Zone): Connect closed circuit contacts of normal acting devices (such as magnetic contacts, foil, etc.) in series with this loop. Maximum permissible resistance: 300 ohms. 194 Fast Response Loop (Basic Protection Zone): Connect closed circuit contacts of fast acting devices [such as vibration contacts (e.g.: No. 1 1 ), glass protection devices (e.g.: No. 9) and photoelectric units without built-in delays] in series with this loop. 56 Maximum permissible resistance: 300 ohms. To lessen the chance of false alarms, the fast response loop should not contain exposed metallic contacts. Notes: An opening in either of those loops, or a short between loops will cause an immediate alarm when the system is ON. Devices with open circuit contacts (such as mats) may be connected between these loops (or into the fast response loop with an Ademco No. 602 Mat Coupler). Entry/Exit Zone: Connect closed circuit contacts on the entry/exit door as well as interior contacts or sensors located in the path between the exit door and the control in a series wiring loop across these terminals. Maximum.permissible loop resistance: 300 ohms. This zone provides entry and exit times of 45 seconds each (30 seconds if the WHTE jumper is cut per Fig. 1). For additional security (against shorts) the Basic Protection Zone s normal response loop may be routed along with the entry/exit loop as shown in Figure 1. A short between these loops when the system is ON, will result in an alarm after the entry delay. 506 497 or -

All interconnections must be made with. U.L. listed limited energy cable. LOOP STATUS SG1 AL POST OR ACCESSORY APPLCATONS) 6V.. 2SAH 4L=J CLOSE ON 1 ALARM (6v. DC TO 24 HR 110 v. AC OUTLET LSTED CLASS 3 XFMR (12V.. 6VA) CUT JUMPER GROUND CABNET TO COLD,WATER,PPE OR ELECTRCAL c BOX, TO AVOD POSSBLE STATC VOLTAGE DAMAGE. AS MAT) CABNET. - A MOUNTlNG *Max. total load permitted to bell plus acces- BASC SCREW sories (on alarm) is 2A. prtsm FGURE 1: Field Connections **f using remote station(s) in lieu of keyswitch control, follow instructions accompanying item(s) used (e.g.: Nos. 244,245.215/216,22?/228.815/816, 5241). * - - - - - - - Optional routing of normal loop (for additional entry/exit loop security). 7.6 9,W+),W-) Emergency (Panic) Switches: Connect locking type open circuit emergency switches (such as No. 264,266,268 or 269) in parallel across these terminals. Operation of an emergency switch at any time (system OFF or ON),will cause the alarm bell(s) to ring and the output contacts to close. Alarms activated from emergency switches do not cut off until the switches are reset. No. 706 Mini-Howler (Optional): Connect as shown in Figure 1. The mini-howler will sound: 1) During the entry delay period. 2) n case of accidental closing with the entry/exit zone open. 3) lf an alarm occurs in the entry/exit zone while the panel is ON. n this last case, the No. 706 will sound until the alarm bell cuts off or the entry/exit loop returns to normal (whichever occurs leer). When sounding, the No. 706 draws 50 ma. 507 498

O,11 12,13 14( + ),20( - ) W+),W-) 17,18 LOOP STATUS SGNAL POST GROUND BLACK, RED LEADS WTH CONNECTOR Keyswitch: Connect a keyswitch with key removable in make and break positions (such as No. 4235) across these terminals (OFF Position: Contacts CLOSED, ON Position: Contacts OPEN). A knockout is provided on the cover of the cabinet for mounting. f this keyswitch is located remotely it should be kept within the protected area. nstead, remote station(s) showing system status may be used, via an appropriate adapter. See ACCESSORES. N.O. Dry Contacts: These contacts may be used to trip a digital communicator, telephone dialer or as desired. The contacts close on alarm (burglary or emergency) and open upon bell cut-off (burglary) or when emergency (panic) switches are manually reset. (The contacts do not close during bell test.) Rating: 2A, 28V. DC/l 1OV. AC. See CAUTON at end of these instructions.. 6V. DC For Accessories: Up to 220 ma continuous load can be connected to these terminals for items such as those described in ACCESSORES. During alarm, up to 2 amperes total combined load may be supplied by these and the alarm bell terminals 15 and 16. 6V. DC Bells or Electronic Sirens having a combined total rating of 2 amperes (less any alarm load connected to term. 14 and 20) may be connected in parallel across these terminals. f electronic sirens are used, observe polarity. Note: Except during an emergency (panic) alarm, cut-off occurs after approximately 12.minutes (8 minutes if the WHTE jumper is cut per Fig. 1). The Alarm Memory LED remains lit until the panel is disarmed. f the protective circuits are then normal, the unit will report any subsequent alarm condition. Power nput, 12V. AC: Turn the keyswitch to its OFF position and connect these teninals to the output terminals of the No. 1320 Transformer. Do not plug in the transformer yet: Used with remote (arming/disarming) station accessories (minimum recommended load resistance: 50K ohms). Ground the cabinet to a cold water pipe or electrical box. Standby Battery: After all other wiring is completed, and with the keyswitch OFF (dosed), connect to the battery when ready to proceed with TESTNG AND CHECKOUT. ALARM PROCESNG CENTER 1025 ZONE STATUS Basic Protection (3ii5-1 Egy FGURE 2: lndica tors ALARM DEVCE MFG. CO. SYOSSET, N.Y. MPORTANT: - CONDUCT BELL TEST REGULARLY TESTNG AND CHECKOUT: Perform these tests after the wiring and connections described in the previous section have been completed. The keyswitch should still be Off and the standby battery must be connected. 1. Plug the transformer into a 1lOV. AC outlet that is ON 24 hours a day. The A.C. POWER LED should light. CAU- TON: DO NOT OPERATE ANY OTHER EQUPMENT SMULTANEOUSLY FROM THS TRANSFORMER. DAM- AGE TO THE TRANSFORMER AND/OR EQUPMENT OR MPROPER SYSTEM OPERATON COULD RESULT. 2. Observe the Zone Status LEDs. Neither will be lit if the protective loops are properly wired and all contacts are properly set. 508 499

4B 3. When both Zone Status LEDs are out, do the following,and observe the appropriate LED light in each case: a. Open the fast response loop momentarily. The Basic Zone LED should light while the loop is open. b. Open the normal response loop momentarily. The Basic Zone LED should lightagain. c. Open the entry/exit loop momentarily. The Entry/Exit Zone LED should light. d. Short the fast and nonal loops momentarily. The Basic Zone LED should light momentarily. e. Short the normal and entry/exit loops momentarily/the Entry/Exit LED should light momentarily. 4. fast the Bell(s) and Standby Battery by depressing the BELL TEST switch momentarily. The bell(s) should ring while the switch is depressed. Any devices connected to the dry contacts will not be activated. Note: The battery may not be fully charged. f this test is tried with a low battery, there will not be enough power to ring the bell. Let the unit charge (transformer plugged in) for at least one half hour if the battery is low. 5. Test the Emergency (Panic) Circuit by momentarily shorting terminals 7 and 8 or tripping an emergency switch. The bell(s) should ring only as long as the short remains and any devices connected to the dry contacts will be activated. 6. Turn the system ON and simulate leaving the premises by following the procedure given in the OPERATON section..note: f an alarm is tripped during testing, the bell(s) can be silenced by turning the keyswitch to OFF. 7. Simulate entering the premises and turn the system OFF by following the procedure given in the OPERATON section. OPERATON: Note: The Zone Status LEDs on the panel will go on and off as the protective loops open and close during normal operation of doors, windows, etc., while the system is OFF. When Turning System ON: 1. A.C. power LED should be lit at all times. f out, AC. failure to unit is indicated. 2. Zone Status LEDs should be off. f lit, protective loop is not set properly. CAUTON: f either Zone Status LED is lit, turning the keyswitch ON will cause an alarm immediately in the case of the Basic Protective Zone or after 90 seconds (exit plus entry delay time) for the Entry/Exit Zone (60 seconds if the WHfTE jumper has been cut). n the latter case, the No. 706 Mini-Howler (if installed) will sound a warning immediately that an alarm can be avoided if the keyswitch is returned to OFF before 90 (60) seconds have expired. 3. Depress BELL TEST Switch to test bell, standby battery and power supply. MPORTANT: For continual assurance that bell, battery and power supply are in proper working order, regular performance of BELL TEST is advised. This is particularly important when remote arm/disarm keyswitches without LEDs.are,used. 4. Turn Keyswitch ON to arm system. Leave via entry/exit door within 45 (30) seconds. When Turning System OFF: 1. Entar only through entry/exit door. f a No. 706 Mini-Howler has been installed, it will sound during the entry delay period. 2. Note if ALARM MEMORY LED on panel is lit (it will be if an alarm has taken place). 3. Turn keyswitch Off before end of entry delay period. ACCESSORES: MPORTANT: Accessories may be used, provided they do not result in a total 6V. DC continuous auxiliary load of more than 220 ma (except as noted below) being drawn from the panel. Total current on ALARM (including alarm sounding device) should not exceed 2 amperes. nstaad of using a keyswftch to control the panel, up to 4 remote stations (e.g.: No. 214.246,246R or 5248) may be used via a No. 244 Remote Station Adapter (each remote station shows system status via a single LED). Current Draw, No. 244 with 1 remote station: 11.5 ma (each add 1 remote station : 9.5 ma). Alternatively, the following are available for coded pushbutton control of the No. 1025: No. 2l6 Two Wire Digital Station with Panic Circuitry (up to 4 can be used via a No. 216 Adapter). Current Draw, No. 216 with 1 No. 215: 11.1 ma (each add 1 No. 215: 9.1 ma). No. 227 Single Button Digital Remote Station (up to 5 can be used, via a No. 228 Adapter). Current Draw, No. 226 with 1 No. 227: 14 ma (each add 1 No. 227: 6 ma). No. 5241 Self-contained Digital Remote Station with Panic Circuitry (single unit only can be used). Current Draw: 12 ma. 509 500

Other available accessories include: No. 245 Remote Station Adapter and Supervised Fire Circuit: Permits the addition of up to 4 remote keyswitch stations on a 2 wire circuit, momentary panic switches (e.g.: No. 219) and a supervised fire circuit to the control. Current Draw: 7 ma plus 9.5 ma per remote station plus Current for smoke or combustion detector power and No. 633 Supervisory Module. No. 262 Fire Module: Permits the addition of an unsupervised fire circuit to the control. Current Draw: 0 ma plus current for smoke or combustion detector power. No. 263 Supervised Fire Module: Permits the addition of a supervised fire circuit to the control with optional No. 706 Mini-Howler annunciation of fire trouble. Current Draw: 5 ma plus current for smoke or combustion detector power and No. 633 Supervisory Module. No. 688 Opening/Closing Switching Module: nterfaces between the control and a digital communicator to signal the communicator to send opening and closing messages as the control is disarmed and armed. Current Draw: 2 ma with high impedance constant load. No. 1034 Zone Expansion Center: Permits additional protection zones to be added to the control by expanding a single protection zone to 4 zones (including a day zone option on 2 of the zones). Current Draw: 20 ma. No. 1035 Day Zone Adapter: Permits the addition of a day or 24 hour zone to the control with day sounder annunciation of disturbances. Current Draw: 6 ma. Complete information accompanies the above accessories. - SPECFCATONS Physical:. Width: 6 (20.3 cm) Height: 15 (38.1 cm) Depth: 3 ( 7.6cm) to _<,.., Electrical: Voltage: 12V. AC (from No. 1320 Plug-in Transformer) Current (per loop): 4 ma Maximum Resistance (per loop): 300 ohms 6V. DC Bell Circuit Output: 2 A maximum (incl. accessories) (3 A Fuse, No. 90-l 2) 6V. DC Accessories Circuit Output: 220 ma max. continuous ;- 2 A max. on alarm (incl. bell circuit),! (3 A Fuse, No. 90-l 2) Output Relay Contacts: SPST, Rating: 2 A at 26V. DC, 11OV. AC r Standby: 6V Sealed Lead Acid Rechargeable Battery, 2.5 A.H. (Ademw No. 496) Up to 60 hrs. standby, dependent upon continuous -- load supplied to accessories. -.-- -~~ ~ ~~~-~~~ MAXMUM STANDBY TMES WfTH VAROUS 1 AUXLARY CRCUT CONTNUOUS LOADS ma: 0 50 100 150 200 220 Hrs: 60 26 14 9.5 7 6 *Loads in addition to control panel and loop currents. c Digital Communicators CAUTON (or Dialers) shall not be set or programmed to place a call to a police station number which has not been specifically assigned by that police station for such service. 510 50.1

511 502