COVER SYSTEMS FOR MINE CLOSURE AND REHABILITATION TWO CASE STUDIES



Similar documents
Updates on Pervious Pavement Design and Construction. Jason T. Peterein, P.E. June 19, 2012

AN AEM TOOL FOR THE EVALUATION OF UNDESIGNED WASTE STORAGE FACILITIES

WILLOCHRA BASIN GROUNDWATER STATUS REPORT

February 4, Report Recommendations and NIPSCO Responses. 4.3 Maintaining and Controlling Vegetation Growth

PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY

1.34 WASTE CONTAINMENT AND SITE REMEDIATION TECHNOLOGY TAKE-HOME FINAL EXAM DUE FRIDAY MAY 7, 2004 AT 9:30 AM

River Basin Management in Croatia

Ontario Mining Act Fact Sheet Mine Closure Plans Your Right to Know!

WORK BREAKDOWN STRUCTURE FOR A TYPICAL MINE

USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE

ANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY

Water remediation: Passive Treatment Technologies

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

WATER QUALITY MONITORING AND APPLICATION OF HYDROLOGICAL MODELING TOOLS AT A WASTEWATER IRRIGATION SITE IN NAM DINH, VIETNAM

Plan Requirement Guidance for Quartz Mining Projects

Abaya-Chamo Lakes Physical and Water Resources Characteristics, including Scenarios and Impacts

Use of Fly ash from KKAB, for sealing of landfills

Environmental risk managements of mine wastes (from planning to aftercare) Marja Liisa Räisänen ELY-centre for Kainuu

CHAPTER 13 LAND DISPOSAL

Ecosystems. The two main ecosystem processes: Energy flow and Chemical cycling

BLACK/HARMONY/FAREWELL CREEK WATERSHED EXISTING CONDITIONS REPORT CHAPTER 12 - STORMWATER MANAGEMENT

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

What are the subsystems of the Earth? The 4 spheres

What is Soil Survey?

4. Environmental Impacts Assessment and Remediation Targets

Soils, Foundations & Moisture Control

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

720 Contour Grading. General. References. Resources. Definitions

Create Your Own Soil Profile Ac5vity

City of London Climate Change Adaptation Strategy Dealing with Extreme Rainfall Events

Best Management Practices for Coal Ash Storage Facilities

Pervious Pavers: Where is the Perviousness?

Erosion Resistance Performance Comparison Of Natracil, Stabilizer And Envirobond s Organic-Lock

Self-Calibrating Remote Control Monitoring Systems

Guidance for Installation of Solar Renewable Energy Systems On Landfills in New Jersey (Updated January 8, 2013)

Environmental Science Science Curriculum Framework. Revised 2005

Managing North Carolina's MSE Wall Assets through Design, Construction and Performance

The Wismut Rehabilitation Project: Present State, Outlook and Lessons Learned

Environmental Remediation Examples and Remediation Strategic Planning

Case study from Ukraine

CIVL451. Soil Exploration and Characterization

Antamina Closure Plan: A Top Level Practice. Eng. Antonio Mendoza, M.Sc., MBA Environmental Manager 2010

2015 AVAGO 2D SEISMIC SURVEY ENVIRONMENTAL MANAGEMENT PLAN SUMMARY

In-pit Tailings Disposal at Langer Heinrich Tailings Storage Facilities in a Unique Hydrogeological Setting C Hore and D Luppnow

Neutralization of Acid Mine Drainage Using Stabilized Flue Gas Desulfurization Material

K. P. Catlett D. G. Adler U.S. Department of Energy, Oak Ridge, TN. P. D. Moss Science Applications International Corporation, Oak Ridge, TN

GoldSim: Engineering and Environmental Simulation Software for the Mining Industry

How To Assess The Vulnerability Of The Neman River To Climate Change

Research of landfill drainage layer clogging

ANIMAL MORTALITY FACILITY

SOAK UP YOUR STORMWATER

Expectations and Future Direction of MOP Guidelines Matthew Newton, Principal Officer Rehabilitation Standards Division of Resources & Energy

Flood risk assessment through a detailed 1D/2D coupled model

The following information is provided in this report or in the listed references;

2x800 MW Thermal Power Project Near Village Paraspani, Tehsil Pathargama, Godda- District By Adani Power (Jharkhand) Limited

Applying MIKE SHE to define the influence of rewetting on floods in Flanders

Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT

B.1 Bioreactor Landfills: Introduction. Conventional Sanitary Landfill (Dry-Tomb approach):

Development of a Technical Management Tool for Settlement and Stability Behaviour of Municipal Solid Waste Landfills

NICHOLS ENVIRONMENTAL (CANADA) LTD. EDMONTON, ALBERTA STATEMENT OF QUALIFICATIONS GEO-ENVIRONMENTAL CONSULTING AND REMEDIATION

Operations and Maintenance Guidelines for Coal Ash Landfills Coal Ash Landfills are NOT the Same as Subtitle D Solid Waste Landfills

The correct answers are given below. Some talking points have been added for the teachers use.

Landfill ER Revenues versus Landfill Costs

Sustainable Groundwater Management for Tomorrow s Livelihoods

SURFACE REMEDIATION AND MANAGEMENT OVERVIEW

Township of Enniskillen. Asset Management Plan

UltraTech International, Inc. Canadian Secondary Containment Requirements

LYNDE CREEK WATERSHED EXISTING CONDITIONS REPORT CHAPTER 12 - STORMWATER MANAGEMENT

Selected aspects of the Danish repository program

Expected Service Life and Performance Characteristics of HMA Pavements in LTPP

NRC INSPECTION MANUAL

Deep geological disposal of radioactive waste in Switzerland - overview and outlook

Current opportunities of sprayed waterproofing membrane. Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction

Alberta Research Council (ARC) Enhanced Coalbed Methane (ECBM) Recovery Project in Alberta, Canada

Anirudhan I.V. Geotechnical Solutions, Chennai

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

A. Describe the existing drainage patterns on-site as shown on Map I, including any potential flooding and erosion problems.

Vulnerability Assessment

Chapter 2 The hydrological cycle

INTERPRETATION ADDENDUM CANADIAN MINING COMPANY INC. SUITE WEST HASTINGS STREET VANCOUVER, BC V6E 3X2 3D INDUCED POLARIZATION

Rehabilitation and closure 23

GETTING TO THE CORE: THE LINK BETWEEN TEMPERATURE AND CARBON DIOXIDE

How fast water travels through soils?

DOÑA ANA COUNTY DESIGN STORM CRITERIA GUIDELINES FOR COMMERCIAL AND RESIDENTIAL SITES. Run-off Analysis Methods

WHAT YOU NEED TO KNOW ABOUT LIVING NEAR INDIANA COAL MINES

Microbiological and Geochemical Dynamics of the Subsurface: chemical oxidation and bioremediation of organic contaminants. Nora Barbour Sutton

Flood damage assessment and estimation of flood resilience indexes

MEMORANDUM. Further discussion regarding the Community s solid waste facility is described further in this memorandum.

EXPERIMENT 10 CONSTANT HEAD METHOD

Lars-Göran Gustafsson, DHI Water and Environment, Box 3287, S Växjö, Sweden

A Correlation of Environmental Science Your World, Your Turn 2011

Sewerage Management System for Reduction of River Pollution

Transcription:

COVER SYSTEMS FOR MINE CLOSURE AND REHABILITATION TWO CASE STUDIES Jason Song 1 and Mike O Kane 2 1 O Kane Consultants Inc., 200 1121 Centre Street N.W., Calgary, AB T2E 7K6, Canada Email: jsong@okc-sk.com 2 O Kane Consultants Inc., 200 1121 Centre Street N.W., Calgary, AB T2E 7K6, Canada Email: mokane@okc-sk.com INTRODUCTION The design of a cover system for mine waste must always depend on site-specific conditions. This paper presents two case studies, EI Sherana airstrip (ESA) cover, Northern Territory, Australia and Whistle Mine Backfilled Open Pit Cover System, Ontario, Canada, focusing on cover system design criteria, design methodology, and performance monitoring, in the context of the site-specific conditions at these two sites. CASE 1 ESA COVER SYSTEM IN SOUTH ALLIGATOR VALLEY, KAKADU NATIONAL PARK, NORTHERN TERRITORY, AUSTRALIA Uranium mining activities in the South Alligator River Valley area in the Northern Territory of Australia took place as far back as 1953. The overall production from the mines was approximately 1,000 t of U 3 O 8. The South Alligator Valley is semi-arid with an average annual rainfall of 1,382 mm/year and average annual potential evaporation (PE) 2,218 mm/year. Figure 1: Location of South Alligator Valley minesite. The overall objective of rehabilitation for this site is to design a containment facility to safely protect radiologically contaminated materials. The containment is to (1) limit ingress of net percolation into the waste from the surface as a primary containment system and (2) limit 1

egress of solutes from the base of the containment as a secondary containment system. The containment facility shall be constructed such that low permeability barriers have a design life of not less than 300 years, and a structural life of not less than 1,000 years. The cover system and landform stability are the key aspects of the primary containment system design, while solute transport through the containment is the main interest of the secondary containment design. The following tasks were completed: Material characterization Geotechnical, geochemical, and radiometric analyses. Landform stability Two scenarios were considered. Cover system - Four cover system alternatives were simulated. Containment - The waste is encapsulated by 0.5 m of compacted clay. Seepage Seepage was predicted for 30 years. Regional groundwater flow and mass transport - The mass transport model was simulated for 300 years. The designed cover system incorporated a 0.5 m thick compacted clay layer (CCL) overlain by minimum of two (2) meters growth medium. The base (and sides) of the containment wastes is underlain by another 0.5 m thick CCL (Figure 2). Figure 2: Visualization of a cross-section through the containment facility. Monitoring and instrumentation of the containment focused on several variables. These were erosion and landform stability, vegetation, cover system water balance monitoring, and leachate monitoring. Instrumentation consisted of three main sensor stations evenly spaced along the long axis of the containment (Figure 3). 2

Figure 3: Schematic of one containment sensor station. CASE 2 - Whistle Mine Backfilled Open Pit Cover System, Ontario, Canada The Whistle Mine site is located approximately 37 km north of Sudbury, Ontario, Canada (Figure 4). Mining of nickel ore occurred between 1988-1991 and 1994-1998. Approximately 7 million tonnes of waste rock was produced. Whistle Mine site is semihumid; and the mean annual precipitation and potential evaporation for the region is approximately 870 mm and 520 mm, respectively. Figure 4: Location of the Whistle Mine site and site plan (after MEND 1997). 3

The cover design objectives are: Reduce O2 ingress to acceptable levels as determined from geochemical modelling; Reduce net percolation to less than 5% of annual precipitation; and Provide a medium for sustainable vegetation and be resistant to erosion. The following tasks were completed: Determination of the preferred material for the barrier layer; Laboratory characterization of the barrier layer and growth medium materials; Soil-plant-atmosphere numerical modelling for determination of the minimum cover layer thicknesses; Slope stability analyses of the preferred pit cover system; Landform evolution and erosion numerical modelling; Design of a performance monitoring programme; and Consideration of the potential impacts of various physical, chemical and biological processes on sustainable performance. The designed final landform had three major components; namely, the cover system itself, the surface water management system, and the surface water collection system (Figure 5). The final cover system design consisted of 0.5 m of compacted silty clay overlain by a minimum of 1.2 m of non-compacted granular fill material (pit-run). Figure 5: Ultimate landform design implemented for the Whistle Mine backfilled pit cover system (from Ayres et al., 2005). Monitoring instruments were installed during construction of the cover system (Figure 6). Field data being collected included precipitation, oxygen and carbon dioxide pore-gas concentrations above and below the barrier layer, net percolation through the pit cover, runoff, and in situ volumetric water content, matric suction and temperature of the cover and upper waste rock materials. 4

Figure 6: Monitoring plan at Whistle Mine backfilled open pit cover system. SUMMARY The presented two cases are located in two different climatic areas. The following experiences were gained: Cover system design and performance monitoring should always be on the basis of site-specific conditions. The cover material characterization is a key aspect. Field test trials are one of the crucial steps. The landform design should be based on the long-term (over 100-year) sustainability and is coupled with cover system design. A robust thickness of growth medium is important to ensure longevity of cover performance. Numerical simulations increase fundamental mechanism understanding, design options, and cover performance predictions, and hence greatly improve the cover design practice. The cost of the cover system should be evaluated on the basis of the total life of the cover. 5

REFERENCES Ayres, B., Lanteigne, L.; and O'Kane, M., 2005, Design and construction of the backfilled pit cover system at Whistle Mine, Canada: a case study, Proceedings of Securing the Future 2005, International Conference on Mining and Environment. Skelleftea, Sweden, June 27-July 1, 2005. MEND, 1997, Whistle mine waste rock study, Mine Environment Neutral Drainage Program (MEND) by Golder Associates Limited in collaboration with SENES Consultants Limited. 6