/ Marley QuadraFlow Cooling Tower /



Similar documents
/ Marley NC Class Cooling Tower /

Sigma Steel CROSSFLOW COOLING TOWER

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

/ Marley Class 800 Mechanical Draft Cooling Tower /

Cooling and Heat Exchanger Solutions

800 class NATURAL DRAFT COUNTERFLOW COOLING TOWER

A Guide to Trouble-Free Cooling Towers

Lenntech. Tel Fax / Ceramic Unilite Cooling Tower /

MAC-120HE-01 Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Transformer oil cooler ALFA A02

Field Service and Replacement Parts for Air Cooled Heat Exchangers

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

RPV - RP - RA air handling units

EMERGENCY VAPOR SCRUBBER SYSTEMS

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

heat treatment equipment & accessories

Geareducer Solutions NEW, REBUILD AND REPAIR OPTIONS FOR EXTENDING THE LIFE OF YOUR COOLING TOWER

Quadraflow cooling tower

Mechanical Rooftop Custom Capabilities

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

NC 8400 steel. Lenntech. Lenntech bv. Tel Fax

Johnson Air-Rotation Systems

ASME Packaged Indirect Fired Water Heater

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

ENGINE COOLING SYSTEM

SIOUX HYBRID WATER HEATER

Medical Air Systems: Scroll

Fiberglass Cooling Towers

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

COOLING TOWERS. This section briefly describes the main features of cooling towers.

cooling tower inspection tips

building engineering services association specification for: Domestic Heating

Solar Hot Water Heaters

Commercial Gas Furnace Upflow

Factory owners must ensure the boiler is:

Element D Services Heating, Ventilating, and Air Conditioning

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Two-Stage Air Conditioner with Puron Refrigerant

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Action Plan Template HVAC Page 1

CE6500 Energy Recovery Ventilator

SECTION AIR COOLED WATER CHILLERS

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

A. Section includes air conditioning units, controls and control panels.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Light Duty Commercial Electric Water Heater

Oil and Coolant Circulating Heating System. Model - OCSM

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Nominal Life Expectancy for Building Components

SECTION HEAT PUMPS

Boiler and Burner Cleaning and Servicing Specifications

University of Houston Master Construction Specifications Insert Project Name

What you can expect from your Solar Hot Water System

SECTION PIPE HANGERS AND SUPPORTS

PLP - TERMS AND CONDITIONS

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

7. COOLING TOWER. 7.1 Introduction

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SECTION 1 GENERAL REQUIREMENTS

CEILING CASSETTE FAN COIL UNIT

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

All-Fiberglass Cooling Towers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Indirect fired heaters

Test Code: 8297 / Version 1

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Explosion-Proof Electric Unit Heaters

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Commercial Electric Water Heater

Removable Insulation Blankets from A to Z

300 Series PA Pump and Cooler Assemblies

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Data center upgrade proposal. (phase one)

ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003

KONRAD. Hybrid Fancoil Series

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

The Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call for more information

Cooking at the Speed of light!

Why Daikin? 2015 Houston, Texas USA

DESIGN STANDARDS SECTION

SECTION AIR CONDITIONING UNIT

Commercial Gas Water Heaters

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Installation Manual CLIFC Fan & Coil Variable Speed

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

TRAM LINE SWITCH POINT HEATING

Transcription:

/ Marley QuadraFlow Cooling Tower /

/ A Truly Unique Cooling Tower Design / The QuadraFlow is a unique cooling tower. Unique in its design unique in its appearance unique in its performance reliability in all seasons unique in its maintainability and unique in its use of inert, noncorroding construction materials. The FRP structure and basins PVC fill, louvers and eliminators and the stainless steel hardware and mechanical equipment support structure all combine to create a cooling tower capable of forgiving the kind of operation and treatment that would destroy lesser towers.

Long Life Construction The QuadraFlow is manufactured and assembled from corrosion-proof materials whose reliability is unquestioned even in very severe operating environments. Low Operating Costs Marley high-efficiency fill and fans, gravity-flow water distribution, and efficient Geareducer drive work together to offer maximum cooling with minimum power use. CTI Certified Although the QuadraFlow s thermal ratings are certified by CTI, SPX Cooling Technologies will not use certification as a means to avoid responsibility. The QuadraFlow is guaranteed to work as well in the real world as it does in the laboratory. SPX guarantees the thermal performance of each QuadraFlow as installed. 5-Year Warranty The QuadraFlow cooling tower is warranted for five full years! This includes fill, mechanical equipment, and structure. All Season Performance The QuadraFlow performs as specified in the heat of summer responds well to energy-management techniques in the spring and fall operates virtually ice-free in the dead of winter and offers simple maintenance all year long. Low Maintenance Induced-draft adjustable-pitch fan Marley System 5 Geareducer stainless steel free floating driveshaft TEFC, 1.15 service factor, horizontal-shaft motor and inert construction materials. Geareducer oil changes are not required for five full years the lowest maintenance requirements in the industry.

/ Features and Benefits /

Air Movement Package Removable fan guard welded heavy gauge rods. Hot dip galvanized after fabrication. Eased inlet fan cylinder assures full area, low turbulent airflow through the cylinder. Marley fan cast aluminum alloy or glass reinforced epoxy. Adjustable pitch blades. Marley System 5 Geareducer no oil changes for five full years. Offers significant savings in maintenance costs. External Geareducer Oil level Gauge and Fill-Drain connection user friendly maintenance. Marley Full-Floating Driveshaft stainless steel tube and non-lubricated neoprene flexible elements assure long, maintenance-free service. TEFC Fan Motor 1.15 service factor, variable torque, and specially insulated for cooling tower duty. Water Distribution System Gravity flow distribution system easy, nonrestrictive maintenance. Basin covers are standard. Marley Spiral Target polypropylene nozzles. Marley MX thermoformed PVC film fill suspended from structural stainless steel tubing. Integral eliminators and louvers keep circulating water confined to fill, even at low air rates. Structure Crossflow configuration easier and safer to maintain. FRP and series 300 stainless steel corrosion proof construction. Four air inlet faces minimizes recirculation. Supporting steel simplifies foundation requirements

/ On-Site Assembly / The QuadraFlow is factory-fabricated, and is designed to be assembled at the jobsite. This allows the design flexibility that results from the unique QuadraFlow configuration and permits a wide variety of orientations. Normally this assembly is included as part of the cooling tower contract, and is performed by erection subcontractors recognized and sanctioned by SPX. Their knowledge and expertise assures proper fit-up, alignment, and sealing of the various tower components and contributes significantly to the trouble-free long-term operation of the tower. It also enables SPX to guarantee the thermal performance of the assembled tower. Therefore, it is strongly recommended that either SPX supervision or complete tower erection be included as part of your order. Nevertheless, we recognize that circumstances may produce situations that require the tower to be assembled by inexperienced personnel without benefit of SPX erection labor or supervision. In support of that, a comprehensive, illustrated, assembly instruction manual is included with every shipment. This manual pictorially identifies the various tower components and provides step-by-step instructions designed to result in a properly assembled installation. Copies of this manual are also available to customers, on request, prior to the shipment of the tower to permit planning of the assembly process. However, we regret that thermal performance of a QuadraFlow cannot be certified or guaranteed without qualified SPX supervision during the assembly process.

TOWER MODELS TONS W H W 21120 129-183 12'-8" 7'-2" 21220 186-211 12'-8" 8'-5" 21320 204-256 12'-8" 9'-9" 22120 243-304 14'-1" 8'-6" W 22220 312-425 14'-1" 9'-11" 23120 390-475 16'-8" 9'-11" 23220 419-546 16'-8" 11'-3" 24120* 531-836 24'-6" 12'-9" H 24220* 796-1047 24'-6" 16'-1" *Models in this box size require a taller fan cylinder / Available Options / Inlet Water Bypass provision for total water bypass directly into the tower collection basin during cold weather operation. Hoistable Steel Grillage allows assembling tower at grade on temporary supports and hoisting into final location. Fire Retardant FRP flame spread rating of 25 or less per ASTM E-84. Control Systems ranging in sophistication from standard fan starters and disconnects to Programmable Logic Controllers that work in conjunction with your building or process system. Variable Speed Drive the ultimate in temperature control, energy management, and mechanical equipment longevity Electric Basin Heater Package maintains collection basin water temperatures between 40 F and 45 F during tower shutdown. Vibration Limit Switch shuts down the fan motor if excessive vibration occurs. Solid State Water Level Control Package monitor basin water level with solenoid-valve water makeup. Configurations include makeup along with high and low water level alarm and cutoff and electric basin heater cutoff. Magnetrol Electric Float Switch monitor basin water level with solenoid-valve water makeup.

The Quadraflow Engineering Data and Specifications Manual QF-TS provides engineering schematics, data, and information necessary for initial tower layout and details the tower in the form of specification language, providing technical as well as common-sense information on the importance of your specifications. Available on the web at spxcooling.com or see your Marley sales representative for a copy. The Marley UPDATE web-based application software provides model selections perfectly tuned to your cooling water system. Functions include model selection, specifications, model optimization, performance curves, engineering data, and free cooling applications. Available to both registered customers and guests at spxcooling.com. If we can help in any way, feel free to call. To find the Marley representative nearest you call 1 800 462 7539 or check the web at spxcooling.com. 7401 WEST 129 STREET OVERLAND PARK, KANSAS 66213 UNITED STATES 913 664 7400 spxcooling@spx.com spxcooling.com In the interest of technological progress, all products are subject to design and/or material change without notice. 2008 SPX Cooling Technologies, Inc. Printed in USA QF-07A