SECTION 273226 (16630) RESCUE ASSISTANCE TELEPHONE SYSTEM (Rev Jun 2011)



Similar documents
GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Walmart 4th Wall. Advertising and Lease Line Guidelines. June Customerexperience

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Scope: Communications and Electronic Systems addressed in this section include:

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

University of Northern Iowa Design Documents Standards. October 2014

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Workspace and storage furnishings

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

PUBLIC RESTROOMS, DESIGN INTENT

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Lucent.

Project Report. Structural Investigations Hotel del Sol Yuma, Arizona

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Ralls County Emergency Services Request for Proposal & Qualifications Emergency Communications Dispatch Consoles

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

BILL OF QUANTITIES Part No.: Part Description

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

UT Southwestern Medical Center Information Resources Cable Installation Standard

HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. Application Guidelines

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10

Vertical Phone System Upgrades Scope of Work

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Solar Panel Installations

6 Signage & Displays External Office Signage Internal Office Signage 6.2 Exhibition Displays 6.3 Slide Presentations

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Fire Alarm System Plans Review Checklist Property location Date of Review

T170 Interior Design Technology MTCU Code Program Learning Outcomes

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Architect/Contractor Information Package

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

Architectural Casework Description of Work

A1.5 Classroom Standards

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

How To Set Up A Minipatch System For A Small Office Or Home Use

Simplified Steel Stair Design for Commercial and Institutional Buildings

signsvisual i n d u s t r i e s servicing New York City since 1991.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

Middleborough Police Electronic Security Narrative

2. What building projects are exempted? (permit not required)

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

Information Technology Solutions

Electrical. This section applies to the design and installation of building power distribution systems.

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

15430 SAFETY SHOWERS AND EYEWASHES

Toll Free:

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Video conferencing. solutions. Communication was never that easy,

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

KONE EN81-71 CAtegory 1. Vandal Resistant Lift

SECTION 807 PUMP STATION REHABILITATION

COMPUTER LAB CLASSROOMS. A Planning Guide

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

Section Summary of Work Contract Security System, Network Infrastructure and UPS Power

Signs And Graphics. Professional Signage and Graphics Solutions

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

A/V and Video Conference Standards for Teaching and Learning Rooms.

SECTION COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

CERTIFICATE OF APPROPRIATENESS APPLICATION INSTRUCTIONS AND CHECK LIST

Building Permits Permit Counter

TCTC Cabling Specifications

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

SECTION GUARDA SECURITY WINDOW SCREENS

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

2. Division 05 Structural Steel Framing for steel framework requirements

Automatic Door Selection Guide

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

A. Shop Drawing submittals shall include, but not be limited to, the following:

Increase your network s security by making the right premise cabling decisions

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

We live in a time of changes. A sofa can be more than just a sofa, an art object can be multifunctional. Furniture can be a work of art.

CLEAR-DIVISIONS CENTERFOLD

Transcription:

SECTION 273226 (16630) RESCUE ASSISTANCE TELEPHONE SYSTEM (Rev Jun 2011) PART 1 - GENERAL 1.00 DESCRIPTION A. Furnish and install hands free communication devices at all areas of Rescue Assistance as indicated on the Construction Drawings. B. Furnish and install non-illuminated modular wall signs. 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplemental Conditions and other Division 1 Specification Sections, apply to this Section. 1.02 RELATED SECTIONS A. Refer to the following sections for additional requirements for the Communications Distribution System (CDS): 1. Standards Section 078413 (07841) Through-Penetration Fire Stop System 2. Standards Section 101000 (10019) Space Identification-Standard 3. Standards Section 260000 (16111) Raceway System 4. Standards Section 260000 (16130) Boxes (Sizes, Styles and Types) 5. Standards Section 260000 (16650) Electrical System-CDS 6. Standards Section 132100 (16652) Requirements for Communication Rooms 7. Standards Section 271000 (16651) Communications Distribution System 8. Standards Section 271000 (16651) APPENDIX-A CDS Approved Products 9. Standards Section 271000 (16651) APPENDIX-B CDS Glossary of Terms 10. Standards Section 271000 (16651) APPENDIX-C CDS Building Acronyms 11. Standards Section 271000 (16651) APPENDIX-D CDS Station Cable Record 12. Standards Section 271000 (16651) APPENDIX-E CDS Typical Rack Layout For Equipment 13. Standards Section 271000 (16651) APPENDIX-F CDS Typical Rack Layout For Data Patch Panels 14. Standards Section 273226 (16630) Rescue Assistance Telephone System 15. Standards Section 275316 (16680) Clock System 16. Standards Section 275319 Distributed Antenna System 17. Standards Section 274100 (16710) Audio-Video (Multi-Media) Systems 18. Standards Section 281300 Electronic Access Control and Intrusion Detection System 19. Standards Section 282300 (16710) Video Surveillance System B. Specification Section 01330 Submittals. Page 1 of 5

C. Specification Section 01600 Product Requirements 1.03 SIGNAGE SUBMITTALS A. Shop drawings under the provisions of Section 01330. B. Drawings: 1. Submit complete shop drawings indicating materials, sizes, configurations and applicable substrate mountings for each specified sign. 2. Submit sign typography sample for message strips and headers copy for each specified sign. 3. Submit signage schedule complete with location of each sign and the required copy; include floor plans as required. C. Product Data: 1. Submit manufacturer s product literature indicating specified devices, and sign units and design selected. D. Submit sign samples under the provisions of Section 01330 illustrating full size sample sign, of type, style and color specified including method of attachment for each sign type. E. Submit manufacturer s installation instructions under the provisions of Section 013300. F. Submit appropriate checklist for aiding in signage reordering after project Substantial completion. G. Submit signage maintenance data and cleaning requirements for all exterior surfaces. 1.04 QUALITY ASSURANCE A. Uniformity of Manufacturer: 1. For each device specified furnish product of a single manufacturer. 2.. For each sign form specified furnish product of a single manufacturer. 1.05 DELIVERY, STORAGE AND HANDLING A. Deliver products to the site under the provisions of Section 016000. B. Store and protect products under the provisions of Section 016000. PART 2 - PRODUCTS 2.01 EQUIPMENT A. Acceptable Manufacturers: 1. Communication Devices: Quality Elevator Products, Inc., NB 5210 Otto, Chicago, IL. 60656, Telephone: (800)222-3699. Page 2 of 5

2. Area Rescue Signage (Architect to verify) a. Innerface Architectural Signage, Inc. b. Andco Industries Corp. c. APCO Graphics, Inc. d. ASI Sign System, Inc. e. Vomer Products, Inc. f. American Arch. Signage Co. B. Communication Device: Hands free flush mounted Telephone with push button and stainless steel cover, embedded Braille instructions, Model ETP-150ETP equipped with back box. C. Wall Mounted Signage Products: 1. Surface Mounted Plastic Signs: As scheduled with one color border and logo. a. Color: As scheduled. 2. Standard Public Room ADA identification signs: For use as standard rescue assistance. PART 3 - EXECUTION 3.01 EXAMINATION A. Signage 3.02 INSTALLATION 1. Verify that signage surfaces are ready to receive work. 2. Beginning of installation means installer accepts existing substrate. A. Communication Devices 1. Install in accordance with manufacturer s instructions. 2. Install stations flush with wall surface at 42 inches to bottom, as per ADA requirements. 3. Provide One Telephone Cable to each station location in conduit, This is a Type 2 Information Outlet (One Telephone Cable, Terminated on a SYSTIMAX MGS400-246 Ivory Jack, and installed in a SYSTIMAX 101SMB-246). 4. All Special Tools that are included with the Communication Device shall be handed over to the owner. 5. Owner shall provide device programming, service connection and testing. B. Rescue Assistance Signage 1. Install in accordance with manufacturer s instructions. Page 3 of 5

3.03 SCHEDULES 2. Install signs after surfaces are finished, in the locations indicated. 3. Install signage holders in locations with mounting types in accord with approved shop drawings. Square, plumb and level units as requires. 4. Clean and polish all installed signage. A. Refer to the interior signage schedule at the end of this section. PART 4 - EXAMPLES 4.01 SAMPLES A. Current EWU standard rescue assistance signage samples to be provided by EWU Sign Shop.. Page 4 of 5

INTERIOR SIGNAGE SCHEDULE Door No. Size Color Mounting Room No. Field Image Height Location Method Text Text Notes END OF SECTION 273226 (16630) Page 5 of 5