EMC Engineering Guidelines For Automation Systems PS 4 PS 416 04/97 AWB 27-1287-GB



Similar documents
Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Structured Cabling, Earthing & Equipotential Bonding

Introduction to Data Centre Design

Good EMC Design Principles: cable routing

Chapter 9. Bonding and Grounding

BX7000 Multi-Access Gateway Getting Started Guide

Universal Vehicle Power Supply 9007AX01. Installation Instructions

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

TC Grounding and Bonding for Telecommunications Systems

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

1. Franklin Rod Performance 2. LEC/DAS Performance

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

About the BitStorm 6051 POTS Splitter

Product and functional description

I NTERFACE CABLE ADAPTER MODULE

Intersection Preassembled 19-inch Rack

Relay mounting systems

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Mounting instructions

5800 Temperature Sensor Cable Assembly

Distribution Boards & Consumer Units

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Cable management for rack-mounted systems

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

This presentation to be used in conjunction with:

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Linkeo 19" freestanding cabinets

What ensures easy and fast wiring?

No Phone Line II-48 System

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Knürr Smaract. Knürr Smaract. CompactRack

Technical Data. Dimensions

Modifying the Yaesu FT-847 External MHz Reference Input

LIEBERT VNSA Installation Sheet

HARTING mcon 3000 Introduction and features

Video Camera Installation Guide

Teleservice via RS232 interface XC100/XC200

HP UPS R1500 Generation 3

Andersen Electric Window Opener for Andersen Awning and Roof Windows

TX OPEN RS232/485 module

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Waveguide Access Point WGA631. Product Guide

P System Cubicles. Certified for more safety

Installation Guide Content for P250xV-240 microinverters

EMC OF INSTALLATIONS AND RECOMMENDED CABLE SEPARATIONS

LOXONE 12 Channel Amplifier

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

Section Grounding and Bonding for Communications

EMC Installation / Application Guidelines VECTORSTAR (VSA) Series Electronics MVS001H. EMC / CE Guidelines

Grounding Demystified

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Shunt lock function 3066

AIR CONDITIONING SYSTEMS

HERZ-Thermal Actuators

Cat7/Class F New Installation Concept New infrastructure. Handbook

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Voice Boxes, Cabinets & Accessories

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Generic - Hearing Loop - (AFILS) U.S. System Specification

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

AC and DC Drive System Installation Information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

800 Communications Circuits

Unified requirements for systems with voltages above 1 kv up to 15 kv

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

LocoNet, the Digitrax Difference

MLH REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL

Low Voltage Switchboards The Best Technical Solution for Your Ship

OPLC Installation Guide

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Minimum Standards for Data/Voice Infrastructure in New Building Construction

OPERATING INSTRUCTIONS

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

TABLE OF CONTENT

Consultants Handbook

5SV Residual Current Protective Devices

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Screened cable and data cable segregation

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Grounding & Bonding Why it is done And How to Install Properly

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

SIMATIC. Automation System S7-400 Hardware and Installation A B. Preface, Contents. Product Overview. Installing the S Addressing the S7-400

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

Transcription:

EMC Engineering Guidelines For Automation Systems PS 4 PS 416 1st edition 04/97 Moeller GmbH, Bonn Author: Werner Albrecht Editors: Klaus Krüger, Thomas Kracht Translator: Chris Baker, Terence Osborn

Contents 1 Fundamentals of Interference-Free Design 3 General comments 3 Low-impedance connection 4 2 Construction of Reference Potential Surfaces 5 Control cabinet design 5 Mounting plates, CI distribution boards 7 Fitting top-hat rails 8 Use of screened cables 9 Incoming external screen cables 10 Inter-building wiring system: screening the line 12 3 Earthing Devices 13 PS 4 compact PLCs 13 PS 416 series of modular PLCs 16 Avoiding RF interference signals, ferrite ring 17 4 Installing a Screen Line Inside a Control C abinet 19 PS 4 compact PLCs 19 PS 416 modular PLCs 20 5 ESD Measures 23 6 Lightning Protection 25 7 Accessories for Interference-free Design 27 Index 29 1

2

1 Fundamentals of Interference-Free Design General comments In order to meet EMC requirements the wiring of systems using the PS 4 and PS 416 must observe certain rules: In particular a uniform reference potential must be created. The reference potential is formed by the totality of all conductively interconnected, inactive metal structures: Control cabinet Cabinet door(s) Support bars Mounting plate Top-hat rail etc. Here you should ensure that there is a low-impedance, conductive connection between all inactive metal structures. The following sections will show you the right way to design your wiring systems. The following rules must always be observed when installing cables : Cables should be grouped by function and then routed so that they are kept spatially separated. Cables with different functions should not be run in parallel. Power cables and signal or data lines should be kept at least 10 cm apart. 3

Fundamentals of Interference-Free Design Low-impedance connection A A low-impedance connection is achieved in the following way: A large-area, low-impedance metal-to-metal connection The use of flexible earthing strips Short connecting wires with a large surface area and contact surface conventional PE conductor with a small crosssection will not be adequate. In the case of enamelled, anodized or insulated metal parts remove the insulating layer in the vicinity of the connecting point. Protect the connecting points against corrosion (for example, by greasing. Important: use only suitable lubricants). The connections of the reference surfaces should comply with the pertinent regulations. 4

2 Construction of Reference Potential Surfaces The construction of the reference potential surfaces is described below - from control cabinet design through to connecting up equipment. Control cabinet design The control cabinet housing is a part of the reference potential surface. To be sure that you have an adequate reference potential surface you will need to observe the following rules: 5

Construction of Reference Potential Surfaces 6 Figure 1: Installation Connect all inactive metal parts (cabinet doors, side parts and so on) to the reference potential surface ensuring you have a large area and low impedance connection. Connect mounting plates together so that they then form a common reference potential surface. Make a large-area low-impedance connection between the protective conductor bar and the reference potential surface (cabinet housing). Connect the guard screen of the screened cables to the reference potential surface using a suitable fastener (cable clip) and making sure the connection is large-area and low-impedance. The

Mounting plates, CI distribution boards Protect cable clip must sit snugly around the entire circumference of the cable screen. Connect the external protective circuit (potential to earth) to the control cabinet reference potential (internal protective conductor bar) with a largearea and low-impedance connection. the all chassis earth connections against corrosion. Mounting plates, CI distribution boards Total You should use mounting plates as your base. Connect the mounting plates to the control cabinet with a low-impedance connection. Use mounting plates made of galvanized sheet steel (no enamelling). The CI distribution board must be fitted with a galvanized mounting plate. The mounting plate of the CI distribution board forms the reference potential surface. insulation is cancelled by implementing the provisions of Reference potential surface. Make sure that connecting points are protected against corrosion. Mounting plates must be connected not only to each other but also to the internal protective circuit with low-impedance and large-area connections so as to form one overall reference potential surface. Here you should connect the mounting plates, mounting sub-plates, metal device plates to the cabinet earthing system as often as possible. 7

Construction of Reference Potential Surfaces Mounting Plate Carrier rail Figure 2: Large-area connections Divided mounting plates as a whole are inactive metal parts and thus form a constituent part of the reference surface. This is why they must also be connected together with low-impedance connections (for example, using galvanized earthing strips). Fitting top-hat rails Fasten the top-hat rail to the mounting plate with a large-area and low-impedance connection. 8

Use of screened cables Use commercially available top-hat rails that are corrosion-proofed. Mounting plate Carrier rail Top-hat rail Top-hat rail Figure 3: Fastening the top-hat rail Use screws or rivets for a large-area and lowimpedance connection of the top-hat rail with the support system. In the case of enamelled, anodized or insulated metal parts remove the insulating layer in the vicinity of the connecting point. Protect the connecting points against corrosion (for example, by greasing. Important: use only suitable lubricants). Use of screened cables The following wires or cables must always be screened: Communications lines Analog lines Counter lines Inter-building data or signal lines (lightning protection) and so on. 9

Construction of Reference Potential Surfaces The cable screen must be earthed as close as possible to the system's source of interference. Always connect both ends of the cable screen to potential to earth. Do not forget here that the potential to earth may have different potentials at the earthing positions. In this case you will need to install a supplementary equipotential bonding conductor with a crosssection of 10 mm 2. Caution! The cable screen must not be used for equipotential bonding. The exposed ends of the cable should be kept as short as possible! Incoming external screen cables Connect the incoming screen cable to the local reference potential surface. Make this connection immediately after entry of the cable into the syste (control cabinet, frame, mounting plate). The following contact paths are possible: Clamp strap snap-on mounting top-hat rail reference potential surface Contact clamp snap-on mounting top-hat rail reference potential surface Contact clamp screwed connection to the busbar reference potential surface Clamp strap screwed connection to the busbar reference potential surface 10

Incoming external screen cables Top-hat rail Busbar M4 Top-hat rail Busbar integrated srew Remove the insulation of screened lines at the contact point. Make sure that the screen braid does not get broken or damaged. It is important that the connection of the busbar with the reference potential surface is short and of low impedance (no insulated segments)! 11

Construction of Reference Potential Surfaces Make a new braided screen contact as close as possible to the device. Inter-building wiring system: screening the line 12 For lightning protection in accordance with ENV 50 142 you should use a suitable surge arrester. Surge arresters manufactured by Messrs Dehn, for example, are suitable here. All inter-building wires and cables must be screened. The screenscreen must not be used as a equipotential bonding conductor as it does not have the requisite current-carrying capacity. For signal lines you should install suitable overvoltage protective devices. These protectors should be fitted wherever possible at the point where the cable enters the building, but never later than the control cabinet. Inter-building lines which are included in the equipotential bonding will need to be routed within metal conduits. These metal conduits must then be earthed at both ends. The minimum cross-sections of the lighting protection equipotential bonding conductors specified by IEC 61 024-1 are as follows: 16 mm 2 copper 25 mm 2 aluminium 50 mm 2 iron With this kind of installation it is not necessary to connect the screen to the equipotential bonding. In addition, with the first consumer in each case following entry into the building you will need to connect a blue surge voltage protector clamp (secondary protector). Then earth the yellow and green terminal of this clamp at the next earthing position.

3 Earthing Devices PS 4 compact PLCs Installation on top-hat rail 24 V 0 V DC devices L1 N AC devices PS4/EM4 Figure 4: Device earthing when installing on top-hat rail Top-hat rail Functional earthing (with DC devices) Protective and functional earthing (with AC devices) Protective conductor bar Connection only with AC devices Protective conductor clamp DC devices: Connect the functional earthing to the reference potential surface as short as possible with a 2.5 mm 2 core cross-section via a protective conductor clamp and top-hat rail for example, from Weidmüller or Phoenix. AC devices: Connect the protective and functional earthing to the reference potential surface as short as possible with a 1.5 mm 2 core cross-section via a protective conductor clamp and top-hat rail for example, from Weidmüller or Phoenix. In addition the protective 13

Earthing Devices earth should be connected as short as possible to the protective conductor bar with a 1.5 m 2 core cross-section. Installation on mounting plates 24 V 0 V DC devices L1 N AC devices PS4/EM4 14 Figure 5: Device earthing when installing on mounting plates Mounting plate Cable lug Functional earthing (with DC devices) Protective and functional earthing (with AC devices) Fixing feet Protective conductor bar Additional connection with AC devices, core crosssection 1.5 mm 2 DC devices: Connect the functional earthing to the mounting plate (reference potential surface) as short as possible and with a 2.5 mm 2 core cross-section.

PS 4 compact PLCs The conductor is connected to the mounting plate via a highly conductive connection which should be as flat as possible; for example, a cable lug. Connect the fixing feet to the mounting plate with a low-impedance connection. AC devices: Connect the protective and functional earthing to the mounting plate (reference potential surface) as short as possible and with a 1.5 mm 2 core cross-section. The protective earth should also be connected as short as possible to the protective conductor bar with a 1.5 mm 2 core cross-section. The conductor is connected to the mounting plate via a low-impedance connection which should be as flat as possible; for example, a cable lug. Connect the fixing feet to the mounting plate with a low-impedance connection. 15

Earthing Devices PS 416 series of modular PLCs Rack You should connect the rack to the carrier system (mounting plate, rack frame, hinged frame and so on) with a low-impedance connection of maximum area. Connect the rack to the protective conductor bar. The protective earthing cable used here must have a cross-section of 6mm 2. The side panels of the rack have been designed to include a connection for the protective earthing cable. Fix the protective earthing cable to the side panel using a punched cable lug (of the correct size!). 16 Figure 6: Earthing the rack Protective earthing cable Protective conductor bar

Avoiding RF interference signals, ferrite ring Avoiding RF interference signals, ferrite ring If RF interference signals are to be avoided, when installing the assemblies you will need to fit the data lines and possibly also the supply lines with ferrite rings. Card Ferrite ring for supply Ferrite ring for data line lin Power supply card PS 416-POW-400 Power supply card PS 416-POW-420 Digital output card PS 416-OUT-400 Digital output card PS 416-OUT-410 Counter card PS 416-CNT-200 Communications card PS 416-NET-210 Communications card PS 416-NET-220 Communications card PS 416-NET-230 Communications card PS 416-MOD-200 Communications card PS 416-COM-200 Fit the ferrite ring directly below the potential equalisation bar. If it is to function correctly the ferrite ring must fit the cable snugly. Use two cable ties at the cable to hold the ferrite ring. After the ferrite ring there should not be any onward runs to other devices. 17

Earthing Devices The ferrite ring is not included in the scope of supply of the cards. Figure 7: Fitting the ferrite ring Cards Ferrite ring P S416-ZBX-405 Cable ties Screen connection Screened data line Supply line Potential equalisation bar 18

4 Installing a Screen Line Inside a Control C abinet PS 4 compact PLCs M4 24 V 0 V PS 4/EM 4 Figure 8: Screen connection to reference potential surface 19

Installing a Screen Line Inside a Control Cabinet Route the screen wire on the left or right in the device using the shortest path. If a DIN connector is used, connect the braided screen with the metal sleeve of the plug. Insulate the end of the braided screen as close as possible to the point where the signal line enters the device. PS 416 modular PLCs A suitable potential equalisation bar for connecting the cable screens can be ordered. The strip is not included in the scope of supply of the racks. The strip is fitted to the bottom front edge of the rack. For this purpose three screws are enclosed with the strip. When attached in this way the strip forms part of the overall reference potential surface. 20

PS 416 modular PLCs PS 416-BGT-4xx PS 416-ZBX-40x M4 12 M4 8 PS 416-ZBX-404 Figure 9: Connecting the cable screens Cable Screen Use a cable clip to connect the cable screen to the potential equalisation bar with a large-area and lowimpedance connection. The cable clip must sit snugly around the entire circumference of the cable screen. 21

Installing a Screen Line Inside a Control Cabinet 15 mm Strip back the cable insulation 15 mm. Bend the cable clip on. Place the clip over the cut-back part of the cable. Pinch the clip together and screw it tightly onto the potential equalisation bar. M4 Caution! The potential equalisation bar must not be used for relieving strain on the signal lines or cables. 22

5 ESD Measures In order to protect the PS 4 and PS 416 programmable controllers against electrostatic discharge, before touching control elements, interfaces and / or data connectors and so on the operator must earth himself (discharge static electricity) by touching a earthed surface. Make sure when using the programmable controllers under normal operation (operating mode 'Run') that the front panels are closed, the front covers are inserted or fitted in place. 23

24

6 Lightning Protection Lightning protection is divided into internal and external lightning protection. By external lightning protection is meant the diversion of the lightning stroke current outside buildings directly into the earthing system. Internal lightning protection limits the effects of the lightning stroke current for example, electromagnetic fields and overvoltages on the electrical equipment downstream. The upstream surge arrester does not form part of the scope of supply of automation equipment. The following illustration shows an example of an upstream surge arrester. CNT-200 24 V DC 2 Figure 10: Use of an upstream surge arrester Lightning protector Ferrite ring Potential equalisation bar Screen Data line Supply line 25

26

7 Accessories for Interference-free Design Snap-on mounting for the top-hat rail for example, Weidmülle FM4 / TS35 Order number: 068790 Screen earth kit Klöckner-Moelle ZB 4-102-KS1 Clamp strap for snap-on mounting Protective conductor clamp for the top-hat rail Earthing strip, tinned for example, Weidmülle KLBü 3-8 SC Order number: 169226 for example, Weidmüller, Phoenix Wago for example, Schlemmer GmbH, Postfach 1309, 85582 Poing, Germany Cross-section 16 mm 2 Item number Schlemmer: 7697536 Ferrite rin Klöckner-Moelle PS 416-ZBX-40 Order number: 025519 Potential equalisation bar for rack PS 416-BGT-420/421 PS 416-BGT-410 PS 416-BGT-400 Upstream surge arreste Klöckner-Moelle Equipment from, for example, Messrs. Dehn PS 416-ZBX-40 PS 416-ZBX-40 PS 416-ZBX-40 Order number: 054124 054125 054126 27

28

Index A Accessories 27 B Busbar 11 C Cable Screened 9 CI distribution boards 7 Connection low-impedance 4 Control cabinet design 5 E Earthing devices 13 Electrostatic discharge 23 F Ferrite ring 17 Fitting 18 Functional earthing 13 I inactive metal structures 3 Installing cables Basic principles 3 L Lightning protection 25 Lines Inter-building 12 Low-impedance connection 4 Mounting plates Earthing 14 O Overvoltage protectors 12 P Potential equalisation bar Fitting to rack 20 R Racks Earthing 16 Reference potential 3 Reference potential surface Design 5 RF interference signals 17 S Screen line Installing inside a control cabinet 19 Screen wire access External 10 Surge voltage protector clamp 12 T Top-hat rail 8 Earthing 13 U Upstream surge arrestor 25 M Metal structures Inactive 3 Mounting plate 7 W Wiring system Inter-building 12 29