apv heat exchanger APV ParaFlow Plate Heat Exchangers

Similar documents
The Industrial Choice. SPRAY TYPE AIR COOLER. Air Cleaning Humidification Air Conditioning Dehumidification Evaporative Cooling

Optimization of Water - Cooled Chiller Cooling Tower Combinations

National Price Rankings

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

HVAC Systems: Overview

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Geothermal Case Studies and Considerations

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Geothermal Heat Pump Systems: From Basics to Hybrids

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Heating & Cooling Efficiency

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Commissioning - Construction Documents (Page 1 of 6)

Tim Facius Baltimore Aircoil

How To Use A Water Source Heat Pump

EnergyPro Building Energy Analysis. Assisted Living Building

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

How to Reduce Energy Costs in Your Commercial Building

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

State Charitable Registration

Public School Teacher Experience Distribution. Public School Teacher Experience Distribution

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

How Ground/Water Source Heat Pumps Work

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

Geothermal Ice Arenas

Impacts of Sequestration on the States

Crowne Plaza Copenhagen Towers The world s greenest hotel

American C.E. Requirements

imagine SOLAR AIR CONDITIONING MADE EASY

GLOBACON 05 HVAC Systems for Cogen

Building Energy Systems. - HVAC: Heating, Distribution -

Benefits. Air-Cooled Systems

Chapter 3.4: HVAC & Refrigeration System

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Sea Water Heat Pump Project

Creating Efficient HVAC Systems

Printing and Publishing Energy Savings Guide

Less Exhaust Gas Less Pollution More Dollar Savings

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Three-Year Moving Averages by States % Home Internet Access

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Information About Filing a Case in the United States Tax Court. Attached are the forms to use in filing your case in the United States Tax Court.

Alabama Commission of Higher Education P. O. Box Montgomery, AL. Alabama

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

APPENDIX B. STATE AGENCY ADDRESSES FOR INTERSTATE UIB CLAIMS

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Impact of Control System Technologies on Industrial Energy Savings

Water cooled chiller plant (cp/vs)

2010 Allocations to States of Volume Cap for Qualified School Construction Bonds

Workers Compensation State Guidelines & Availability

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

National Grid Your Partner in Energy Solutions

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

Glossary of Heating, Ventilation and Air Conditioning Terms

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Data Center Planning. PUE Overview

MAINE (Augusta) Maryland (Annapolis) MICHIGAN (Lansing) MINNESOTA (St. Paul) MISSISSIPPI (Jackson) MISSOURI (Jefferson City) MONTANA (Helena)

NON-RESIDENT INDEPENDENT, PUBLIC, AND COMPANY ADJUSTER LICENSING CHECKLIST

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Case Study. Southwestern Manitoba town simplifies ice-making while reducing costs. Miami, Manitoba Hockey Arena and Community Hall

Chex Systems, Inc. does not currently charge a fee to place, lift or remove a freeze; however, we reserve the right to apply the following fees:

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Energy Efficiency in Industrial HVAC Systems

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Pharmaceutical central utility plants

HVAC EFFICIENCY STANDARDS

See any red flags? Let s take a look at the problems that occurred on the job and how to avoid making the same mistakes.

The next generation of geothermal systems for school buildings

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Thermal Energy Storage Strategies for Commercial HVAC Systems

Heat Recovery In Retail Refrigeration

SOLAR COOLING WITH ICE STORAGE

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Online Labor Demand Shows Strong Increases, up 217,900 in December

By Tom Brooke PE, CEM

The Obama Administration and Community Health Centers

Licensure Resources by State

3/29/2012 INTRODUCTION HVAC BASICS

RECONNECTING OPPORTUNITY YOUTH

HVAC Processes. Lecture 7

ROTEX gas hybrid heat pump. A strong team.

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Transcription:

apv heat exchanger APV ParaFlow Plate Heat Exchangers For HVAC Applications

SPX offers an extensive portfolio of plate heat exchanges covering many industrial applications. Regularly SPX heat exchangers replace older technology products due to the simplicity of installation and their high performance thermal characteristics. Whether recovering waste heat or isolating the cooling system from the cooling source, SPX has the application knowledge and product to improve efficiency and performance. Our vision for the future is rooted in a long standing tradition of excellence and commitment to progress. We strive to offer the customer the highest quality products and services today, tomorrow and beyond. Technology, Performance & Value APV is a leading innovator of solutions specifically designed to meet the challenges of the HVAC market. APV provides a broader selection of plate sizes and corrugation patterns offering the greatest number of options and thermal lengths, ensuring you get the solution that best meets your needs. Advantages for HVAC Applications Reduced operating and maintenance costs Compact size Modular design facilitates installation in areas where space is limited Flow rates up to 11,000 PM Design pressures to 0 PSI High efficiency design for smaller heat exchangers with lower pressure drops Computerized thermal rating optimizes plate types for maximum efficiency Full ASME code compliance SPX provides advanced APV heat transfer solutions for cooling, heating, condensing and evaporation of process fluids - Water Source Heat Pump Today, heat pumps are widely used in HVAC applications. An open cooling tower is typically combined with a plate heat exchanger as the preferred alternative to closed circuit coolers. With the APV you can be assured that contaminated water from sources such as open cooling towers, water wells, streams and lakes will be isolated from the closed loop heat pump system. designed to solve heat transfer process challenges in a vast array of industries. They are designed to meet demanding process conditions and to optimize the utilisation of energy. APV heat transfer solutions have proven reliable and highly efficient helping customers worldwide to run their processes safely and economically. Dedicated and specialized SPX staff around the world is committed to design and provide efficient and durable heat transfer solutions to help customers optimize energy utilization and minimize downtime for improved profitability. Heat Pumps Water Source 2 Chiller AHU

s Thermal Storage Thermal storage systems are being used to efficiently manage peak building cooling loads. During the night, the chiller capacity is used to cool water or produce ice in a thermal storage reservoir. During the day, when loads are at their peak, the stored cooling is used to handle the demand. The thermal storage system will reduce utility costs as the chiller is operated at night when energy rates are lower. Mechanical equipment loading is also minimized through the use of this system. Since glycol or brines are often used in the chillers, Water Source the Heat Pumps is used to isolate these fluids from the rest of the system and act as a pressure block to the storage reservoirs. Typical product applications Free cooling Heat recovery Water source heat pump Thermal storage Chiller AHU Pressure interceptor Evaporator AHU District heating and cooling Thermal Storage Tank Free A waterside economizer system using a plate heat exchanger will save thousands of hours of mechanical refrigeration, which translates to tremendous bottom-line benefits. Using the free cooling available in the outside air under optimum wet bulb conditions, this system delivers cooling tower water with a temperature that minimizes chiller operation. The key is the highly efficient plate heat exchanger, which provides heat transfer and simultaneously isolates and protects expensive air conditioning equipment from tower water contamination. Building Condensor Evaporator 3

System Advantages In most cases payback is in less than 18 months Lower energy costs and longer chiller life High efficiency and less maintenance through prevention of contamination and fouling in the building chilled water system Eliminates duct work required for air-side economizers, saving space and money No moving parts minimizes maintenance meets retrofit demands of existing structures High efficiency allows close approach temperatures (i.e. 2 F), increasing your hours of free cooling Example: Fort Bragg, NC 380 tons x.90 KW/ton = 342 KW 342 KW x 1734 hrs (37 wb or lower) = 593,028 KWH 593,028 KWH x $.05/KWH = $29,651/yr Approximate Hours of Operation state city 47 WB 7 a.m. - 7p.m. 38 wb 7a.m. 7 a.m. - 7p.m. Energy Savings Calculations The following information must be known: Approximate winter tonnage Efficiency of chiller Hours of operation at winter design wet bulb Approach temperature between cooling tower water and building chilled water temperatures (i.e. 37 F tower water @ 2 F approach, nets a building water temperature of 39 F). Pressure Interceptor In tall buildings, HVAC systems that use water, glycol and brine often experience problems with pressure build-up from static head. The plate heat exchanger is used at various elevations to create separate circulation loops and reduce the operating pressure throughout the system. The lower operating pressure allows you to use standard equipment for pumps, valves, chillers and evaporators. Energy savings in pump horsepower can also be achieved. alabama Birmingham 1,848.2 1,009 800.6 427 Alaska Arizona Anchorage Phoenix 6112.4 3,378 1,722.9 939 4,733.6 2,612 167 75 california colorado Sacramento Denver 620.6 327 4,373.6 2,412 183.2 84 3,014.6 1,657 georgia Atlanta 2,255 1,235 1,065.2 574 illinois Chicago 3,833.6 2,112 3,178.4 1,748 kentucky Lexington 2,847.2 1,564 1,808.6 987 massachusetts Boston 4,145 2,285 3,043.4 1,673 michigan Detroit 4,305.2 2,374 3,398 1,870 minnesota Duluth 5,210.6 2,877 4,224.2 2,329 mississippi Jackson 1,526 831 615.2 324 nevada Las Vegas 2,145.2 1,174 780.8 416 new hampshire Portsmouth 4,231.4 2,333 3,245 1,785 new jersey Cherry Hill 3,619.4 1,993 2,418.8 1,326 new york Buffalo 4,130.6 2,277 3,279.2 1,804 ohio Cincinnati 3,547.3 1,953 2,494.4 1,368 oklahoma Tulsa 2,750 1,410 1,459.4 793 Chiller Oregon Portland 3,421.4 1,883 989.6 532 Virginia Richmond 2,739.2 1,504 1,551.2 844 F C 4

District Heating and The PHE can be used in low pressure steam, hot water and chilled water district heating and cooling systems. The savings realized, incorporating one large centralized plant rather than many small units, is evident over time. The is used as an instantaneous heater and separation Building device from the main loop in each building. Hot or chilled water is Condensor Evaporator sent to each building via the insulated pipes from the central plant. The heat exchanger transfers the heat to the closed freshwater loops circulating through each building. This provides isolation and pressure interception for the water loops. It also provides a constant pressure drop for the central plant. s Lake Source A good example of Lake Source is a Northeast University needed to replace their campus cooling system that dated back to the early 1960s. Several of their chillers used chlorofluorocarbons (CFCs), which could not be converted to non-cfc refrigerants. As they explored their options, they began to seriously consider the installation of a lake-source cooling system. After extensive testing and environmental review, the university decided to move forward with the lake source cooling system to cool all of the buildings throughout campus. How it Works: Cold lake water is pumped to APV heat exchangers at the shore, which absorbs some of the heat from the water used to cool the University, then returns to shallow waters in the lake. The deep waters of the lake are a naturally renewable source of chilled water that saves 80% of the energy used to cool by conventional refrigeration. The closed loop system also minimizes the required energy needed to operate, since the return water coming down the hill to the lake shallows creates a vacuum which pulls the deep cold water from the lake up to the campus. The core of the system consists of seven 12 300 PSI APV heat exchangers that are in parallel arrangement, allowing any combination of pumps and heat exchangers to be on line to meet the requirements to control the comfort of 75 campus buildings. Centralized Boiler Loop 5

Heat Recovery From Condenser Water Heat contained in condenser water can be recovered using a plate heat exchanger between the condenser and the cooling tower. The highly efficient captures the free heat, preheats domestic and building water, and reduces the load to the cooling tower. From Waste Heat The allows you to recover heat from sources such as institutional buildings which consume large amounts of hot water, offices where heat is generated by building occupants and equipment, as well as commercial and manufacturing complexes producing heat from machinery and process liquids. In the absence of a PHE heat recovery unit, millions of BTUs would be exhausted into the surrounding environment and be wasted. Start Benefiting Today APV plate heat exchangers minimize downtime while reducing maintenance time and expenses, delivering all the benefits you need to improve your profitability. SPXs experienced engineers will work with you every step of the way from system design to implementation, to ensure you get the solution that best meets the needs of your process. To learn more about how SPX can help you improve your profitability, call us today at +1-800-207-2708. Unheated Water Condenser From Condenser Water Preheated Water Unheated Water Condenser Preheated Water From Waste Water Computer Room Any water to be preheated

A WIde range of plate heat exchangers for hvac applications Model Connection Diameter In/(MM) Maximum US PM (LPM) Plate Options: -asketed D-Dual Safety L-Semi-Welded Approx. Height in/(mm) Approx. Width in/(mm) Approx. Length in/(mm) Maximum Surface Area Sq. Ft. (SQ. M.) AR2-1 2.0 (50.8) 200 (757.082), D, L 44 (1,117.6) 15 (381) 27-67 (685.8-1,701.8) 650 (60.38) AR3-1 3.0 (76.2) 460 (1,741.289), D 63 (1,600.2) 18.5 (469.9) 23-108 (584.2-2,743.2) 1,900 (176.52) AR4-1 4.0 (50.8) 800 (3,028.329) 50 (1,270) 25 (635) 54-113 (1,371.6-2,870.2) 1,550 (143.99) AR4-2 4.0 (101.6) 800 (3,028.329) 68 (1,727.2) 25 (635) 54-113 (1,371.6-2,870.2) 2,850 (264.77) AR4-3 4.0 (101.6) 800 (3,028.329) 91 (2,311.2) 25 (635) 54-113 (1,371.6-2,870.2) 4,200 (390.19) AR6-1 67 (1,701.8) 29 (736.6) 41-114 (1,041.4-2,895.6) 2,700 (250.83) AR6-2 85 (2,159) 29 (736.6) 41-114 (1,041.4-2,895.6) 4,150 (385.55) AR6-3 122 (3,098.8) 29 (736.6) 41-114 (1,041.4-2,895.6) 6,900 (641.03) AR6L-1 64 (1,625.6) 23 (584.2) 46-134 (1,168.4-3,3.6) 2,5 (223.43) AR6L-2 92 (2,336.8) 23 (584.2) 46-134 (1,168.4-3,3.6) 4,770 (443.15) AR8-1 62 (1,574.8) 36 (914.4) 55-151 (1,397-3,835.4) 3,950 (366.97) AR8-2 77 (1,955.8) 36 (914.4) 55-151 (1,397-3,835.4) 6,250 (580.64) AR8-4 103 (2,616.2) 35 (889) 54-119 (1,371.6-3,022.6) 7,960 (739.50) AR8-5 122 (3,098.8) 36 (914.4) 55-151 (1,397-3,835.4) 13,800 (1,282.06) AR9-2,L 86 (2,184.4) 33 (838.2) 60-126 (1,524-3,200.4) 5,050 (469.16) AR9-3,L 103 (2,616.2) 33 (838.2) 60-126 (1,524-3,200.4) 6,700 (622.45) AR9-4,L 120 (3,048) 33 (838.2) 60-126 (1,524-3,200.4) 8,700 (808.25) AR12-1,L 75 (1,905) 6,100 (566.71) AR12-2,L 94 (2,387.6) 10,700 (994.06) AR12-3,L 109 (2,768.6) 12,850 (1,193.80) AR12-4,L 119 (3,022.6) 15,050 (1,398.19) AR12-5,L 138 (3,505.2) 19,0 (1,802.32) AR16-1 1 (6.4) 13,200 (499,674.36) 106 (2,692.4) 51 (1,295.4) 137-256 (3,479.8-6,502.4) 17,600 (1,635.09) AR16-2 1 (6.4) 13,200 (499,674.36) 118 (2,997.2) 51 (1,295.4) 137-256 (3,479.8-6,502.4) 22,500 (2,090.32) AR16-3 1 (6.4) 13,200 (499,674.36) 130 (3,302) 51 (1,295.4) 137-256 (3,479.8-6,502.4) 25,700 (2,387.60) The APV liquid to liquid plate heat exchanger has earned the trusted AHRI Performance Certified mark, an assurance of the product s performance in accordance with AHRI Standard 0.

APV ParaFlow Plate Heat Exchangers for HVAC Applications lobal locations SPX Flow Technology 1200 West Ash Street P.O. Box 1718 oldsboro, NC 27533-1718 USA T: +1 (919) 735-4570 F: +1 (919) 731-5498 E-mail: answers.us@spx.com SPX Flow Technology Platinvej 8 6000 Kolding Denmark T: +45 70 278 444 F: +45 70 278 445 E-mail: apv.emea.heat@spx.com SPX Flow Technology 666 Fengjin Road Xidu Industrial Park Fengxian P.R. China. Tel: +86 21 67158181 Fax: +86 21 67158282 About SPX Based in Charlotte, North Carolina, SPX Corporation (NYSE: SPW) is a global Fortune 500 multi- industry manufacturing leader. For more information, please visit www.spx.com SPX Flow Technology 105 CrossPoint Parkway etzville, NY 168 P: (800) 462-6893 F: (716) 692-1715 E: answers.us@spx..com SPX reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed in writing. Please contact your local sales representative for product availability in your region. For more information visit www.spx.com. The green > is a trademark of SPX Corporation, Inc. ISSUED 12/2012 1102-01-08-2008-US COPYRIHT 2012 SPX Corporation