BURNER WATER CONTROL UNIT



Similar documents

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Oil and Coolant Circulating Heating System. Model - OCSM

Oil - kerosene burners

Condensate water pump with neutralisation system

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

USER S MANUAL HSC-24A

Conlift1, Conlift2, Conlift2 ph+

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO. PENTOLE ELETTRICHE INDIRETTE 100/150Lt N900 ELECTRIC BOILING PAN INDIRECT HEATING 100/150Lt N900

REV 000A. High Quality Nautical Equipment BALDER BLD 600 BLD 900 BLD 1200

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

LISTA RICAMBI / PART LIST

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

SunMaxx Solar Filling Station Operating Instructions

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

MODEL INSTALLATION INSTRUCTIONS

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

GUARNIZIONI PRINCIPALI / KIT - MAIN GASKETS / SET

Please also see 10 golden rules for correct Saniflo installation on

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Technical Guide 08/15/14

SMD Rework Station TABLE OF CONTENTS

ELECTRIC INSTANTANEOUS WATER HEATER

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Overheating limit control

Hydraulic control unit series

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

TOBY DVR5 OIL CONTROL & SAFETY VALVE

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

Safety, Operation and Maintenance Manual with Parts List

IH E Sigma Island 90

AHE S SERVICE MANUAL

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Compressor Service & Maintenance Manual

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

WASHING MACHINE READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE.

TMS TANK MANAGEMENT SYSTEM

McSmart 160C. McSmart 160C INDICE / INDEX SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Cooling system components, removing and installing

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

AFE424 SERVICE PARTS

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

Instruction manual. Electrobloc EBL 100-2

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

GENIX AUTOMATIC LIFTING STATIONS

HOT MELT APPLICATION. ideas, technology, performances

Evaluate, Clean, and Tune Guidance

Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander

COMPRESSOR REPLACEMENT PROCEDURE

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

LIMITED LIFETIME WARRANTY

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

GENERATOR MODEL NO: FG3050 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0310

Float and Thermostatic Traps Series H, C and X

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

Hydrocollator. Operation Manual SS E-2 E and 220/240 Volt Units.

Zenith Solar thermal 4.5m pump station Installation manual

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

MDT5N25 & MTD5N40 SERVICE PARTS

CARATTERISTICHE TECNICHE / TECHNICAL SPECIFICATIONS. Temperatura di impiego Operative temperature. Passaggio nominale Nominal diameter

VOYAGER 570G. 744A Sprayer Control

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...


EC DECLARATION OF CONFORMITY FOR MACHINES

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

User manual. 086U6297 Rev. 9 EN

OS Instruction Manual. Electronic Controllers for Reverse Osmosis Plants. Software version

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

MCT-7 Multiple Cable Test System

A sophisticated design for a demanding field. prima series

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

Unvented water heater

ECOCIAT. Domestic hot water heat recovery unit

Spare Parts List M96A.24SM/B M96A.28SM/B

Transcription:

BURNER WATER CONTROL UNIT Energy Saving Technology MODELS AQUAMATIC 1 A / B AQUAMATIC 2 A / B LB 1003 04.12.98

TABLE OF CONTENTS: TECHNICAL SPECIFICATIONS FOR AQUAMATIC CONTROL UNITS.... pag. 4 WATER CIRCUITS...................................................................... pag. 4 INDICATOR PANEL.................................................................... pag. 5 ELECTRICAL WIRING DIAGRAMS.................................................. pag. 5 START UP................................................................................. pag. 6 PRIMING THE CONTROL UNIT..................................................... pag. 6 ADJUSTING EMULSION WATER DELIVERY....................................... pag. 7 MAINTENANCE......................................................................... pag. 8 CONTROL UNIT BLOCK............................................................. pag. 8 EXPLODED VIEWS OF CONTROL UNITS......................................... pag. 9 pag.3

TECHNICAL SPECIFICATIONS MODEL OF CONTROL UNIT AQUAMATIC 1A AQUAMATIC 1B AQUAMATIC 2A AQUAMATIC 2B Voltage V 400~50 Hz 400~50 Hz 400~50 Hz 400~50 Hz Max. power consumption W 350 500 700 850 Max. water spray delivery kg/h 20 62 40 82 Overall dimensions LxHxP mm 600x750x590 600x750x590 600x750x590 600x750x590 Weight kg 48 51 57 60 WATER CIRCUITS Aquamatic control units for single stage burners Water inlet tank 7 6 P 8 burner 9 1 5 3 2 4 1 - Filter 2 - Pump 3 - Hidraulic shock absorber 4 - Flow adjuster 5 - Drain cock 6 - Tank with ball cock 7 - Overflow 8 - Pressure switch for water level control 9 - Non-return valve Aquamatic control units for two stage burners fig. 1 Water inlet tank 7 6 P 8 burner 9 1 5 3 2a 2b 4 4 1 - Filter 2a - 1st stage pump 2b - 2nd stage pump 3 - Hidraulic shock absorber 4 - Flow adjuster 5 - Drain cock 6 -Tank with ball cock 7 - Overflow 8 - Pressure switch for water level control 9 - Non-return valve fig. 2 pag.4

INDICATOR PANEL 6 5 4 3 2 1 fig. 3 1 - Main switch 2 - Fuse 3 - Lock out lamp 4-1st flame lamp 5-2nd flame lamp 6 - Remote switch access cover ELECTRICAL WIRING DIAGRAMS SINGLE STAGE AQUAMATIC CONTROL UNITS R S T NO KMP1 HL1 HLB SPA FMP1 FMP1 MP1 M 3 ~ FU 400V SAL 230V Q Q main interruttore switch generale FU FUfuse fusibile KA KArelayrele' HL1 HL1first stage lampada flame di lamp prima fiamma HLB HLBlock out lampada di blocco MP1 MP1 pump motore pompa SAL SAL working interruttore switch di linea SPA SPA water pressostato pressure switch di controllo livello acqua FMP1 FMP1 pump rele' motor termico thermal motore relay pompa KMP1 KMP1 pump contattore motor contacts motore pompa Q L2 N L1 CONNECTION COLLEGAMENTO TO AL BRUCIATORE BURNER 50Hz~400V PE R S T BEM29.002 fig. 4 pag.5

TWO STAGE AQUAMATIC CONTROL UNITS R S KMP1 T NO HL1 HLB R S KMP2 T NO HL2 SPA FMP1 U V W U V W MP1 MP2 M M 400V 230V 400V 230V FMP2 FMP1 FU SAL Q main switch FU fuse Q interruttore generale KA FU relayfusibile HL1KA first rele' stage flame lamp HL2HL1second lampada stage di flame prima lamp fiamma HLBHL2lock lampada out lampdi seconda fiamma MP1HLBpump lampada motordi blocco MP1 motore pompa MP2 pump motor MP2 motore pompa SAL SALworking interruttore switchdi linea SPA SPAwater pressostato pressure switch di controllo livello acqua FMP1 FMP1 pump rele' motor termico thermal motore relay pompa FMP2 FMP2 pump rele' motor termico thermal motore relay pompa KMP1 contattore motore pompa KMP1 pump motor contacts KMP2 contattore motore pompa KMP1 pump motor contacts L2 N L1 Q CONNECTION COLLEGAMENTO ALTO BRUCIATORE BURNER 50Hz~400V PE R S T BEM29.001 fig. 5 START UP PRIMING THE CONTROL UNIT - Connect the control unit to the water supply through pipe A (fig.6) - The ball cock shuts off the water when tank B is full. - Fit a Ø 8 x 1 mm copper pipe between the burner and the control unit. Make sure that the pipe, which is not supplied, is of an appropriate length and has a bell end. - Connect this pipe to the control unit at point C, and leave the other end free for the time being. - Operate the remote switch under the cover on the indicator panel for a few seconds, until the pump pumps water out of the free end of the pipe. With two stage control units, repeat with the second remote switch for the second pump. This bleeds air from the water circuit. Water inlet body on burner Tubo Ø 8 x in 1mm rame copper ø6x1mm pipe bruciatore burner A D non-return Valvola di valve ritegno ;; ; C B fig. 6 Emulsion water inlet plug P Supplied with the control unit - Finally, connect the free end of the pipe to the burner at point D. Take care to fit the non-return valve as shown in the diagram in fig.7. Water connection Non-return valve Union Olive nozzle Lock nut pag.6 fig. 7 Ø 8 x 1mm copper pipe

ADJUSTING EMULSION WATER DELIVERY Emulsion water delivery must be about 10% of fuel oil delivery to the burner. The following table shows the maximum water flow rates for the various AQUAMATIC control units. AQUAMATIC SINGLE STAGE CONTROL UNITS model of control unit Water delivery (kg/h) AQUAMATIC 1A 20 AQUAMATIC 1B 62 AQUAMATIC TWO STAGE CONTROL UNITS model of Water delivery Water delivery control unit 1st stage (kg/h) 2nd stage (kg/h) AQUAMATIC 2A 20 20 AQUAMATIC 1B 62 20 Caution! Single stage control units can be connected to two stage burners. In such cases the emulsion water supply is always connected only to the second burner stage. COMBINATION TABLE FOR AQUAMATIC CONTROL UNITS AND OILFLAM BURNERS SINGLE STAGE CONTROL UNITS (EMULSION WATER ONLY TO 2nd STAGE) model of model number of control unit of burner burner stages AQUAMATIC 1A oilflam 50 1 AQUAMATIC 1A oilflam 80 2 AQUAMATIC 1A oilflam 120 2 AQUAMATIC 1B oilflam 170 2 AQUAMATIC 1B oilflam 200 2 AQUAMATIC 1B oilflam 300 2 AQUAMATIC 1B oilflam 400 3 TWO STAGE CONTROL UNITS model of model number of control unit of burner burner stages AQUAMATIC 2A oilflam 80 2 AQUAMATIC 2A oilflam 120 2 AQUAMATIC 2A oilflam 170 2 AQUAMATIC 2B oilflam 200 2 AQUAMATIC 2B oilflam 300 2 AQUAMATIC 1B oilflam 400 3 Adjust water delivery by means of the graduated knob on the right hand side of the pump (see fig.8). The graduated scale from 0 to 100 shows the percentage of maximum deliverable flow. The setting must therefore be made according to the fuel oil burner model and the type of nozzle/s fitted. 0 100 fig. 8 EXAMPLE No.1 OILFLAM 80 TWO STAGE BURNER WITH AQUAMATIC 1A CONTROL UNIT 1st stage burner nozzle: 7.0 gph = 45 kg/h fuel oil 2nd stage burner nozzle: 5.5 gph = 35 kg/h fuel oil 40% Total flow of fuel oil: 45 + 35 = 80 kg/h Water requirement: 8 kg/h approx. 8:20 = 0.40 = 40%. Turn knob to 40%. EXAMPLE No.2 OILFLAM 200 TWO STAGE BURNER WITH AQUAMATIC 2A CONTROL UNIT 1st stage burner nozzle: 15.0 gph = 98 kg/h fuel oil 2nd stage burner nozzle: 9.50 gph = 61 kg/h fuel oil Water delivery to 1st stage: 9.8 kg/h approx. Water delivery to 2nd stage: 6.1 kg/h approx. 9.8: 20 = 0.49 = 49% 6.1:20 = 0.30 = 30% Set the two pumps to these values. 0 100 0 1st Pompa stage 1 pump stadio 49% 100 fig. 9 fig. 10 Pompa 2nd stage 2 pump stadio 30% 0 100 Note: Fine tuning of emulsion water delivery for optimum burn must be made on the basis of smoke analysis. pag.7

MAINTENANCE CLEAN THE WATER FILTER AT REGULAR INTERVALS. TO DO SO PROCEED AS FOLLOWS (SEE FIG.11): - Switch the control unit off. - Shut off the water supply. - Drain off all the water from the control unit's water circuit by opening the drain cock on the water filter. - Unscrew the bowl A. Use wrench B (supplied with the control unit). - Pull out filter C and rinse it thoroughly to remove all dirt and impurities. Blow clean with compressed air if necessary. - Reassemble in the reverse order. - Open the water supply. - Switch on the control unit. C A B fig. 11 CHECKING THE OIL LEVEL 2 Check the oil level in window 1 (fig.12) at regular intervals. Always do so with the pump motor/s off. Top up if necessary through plug 2, again always with the pump motor/s off. Caution! Use only SAE 140 oil. 1 1 - Oil 1 - level spia livello window olio 2 - tappo rabbocco olio 2 - Oil filler plug 3 - tappo scarico olio 3 - Oil drain plug 3 fig. 12 CONTROL UNIT BLOCK The block indicator lights whenever the control unit's thermal relay (cut-out) trips or if there is no water supply. If this occurs, the burner will continue to burn without emulsion water. Identify and solve the cause of the problem. If the burner blocks, the control unit automatically stops too. pag.8

EXPLODED VIEWS OF CONTROL UNITS Aquamatic 1 A-B 2 1 6 5 4 7 14 13 11 10 9 8 12 15 19 18 16 17 fig. 13 pag.9

Aquamatic 2 A-B 2 1 6 5 3 4 7 14 13 11 10 9 8 15 12 20 19 18 16 17 fig. 14 pag.10

Pos. Description Aquamatic 1A Aquamatic 1B code code 1 - WATER FILTER ATLAS INOX S1.02 S1.02 2 - FLOAT Q2.01 Q2.01 3-2nd STAGE WATER PUMP CUCCHI - - 4-1st STAGE WATER PUMP CUCCHI P1.54 P1.55 5 - CASTING BFC12.029 BFC12.029 6 - HYDRAULIC SHOCK ABSORBER GR.MAR.01/1 GR.MAR.01/1 7 - PUMP BRACKET BFC12.021/001 BFC12.021/001 8 - WIELAND CONNECTOR (MALE) 4 PIN E2.22 E2.22 9 - WIELAND CONNECTOR (FEMALE) 4 PIN E2.23 E2.23 10 - WATER PRESSURE SWITCH HUBA 605 Q1.18/2 Q1.18/2 11 - RELAY SOCKET FINDER R9.05 R9.05 12 - RELAY FINDER R7.11 R7.11 13 - CONTACTOR LOVATO N 1 R6.03/1 R6.03/1 14 - THERMAL RELAY LOVATO N 1 R5.10/8 R5.10/8 15 - FUSE HOLDER FUSIT E8.02/2 E8.02/2 16 - FUSE FUSIT E8.04/1 E8.04/1 17 - MAIN SWITCH R10.01 R10.01 18 - LOCK-OUT LAMP RED E15.09 E15.09 19-1st STAGE FLAME LAMP GREEN E15.07/2 E15.07/2 20-2nd STAGE FLAME LAMP GREEN - - Pos. Description Aquamatic 1A Aquamatic 1B code code 1 - WATER FILTER ATLAS INOX S1.02 S1.02 2 - FLOAT Q2.01 Q2.01 3-2nd STAGE WATER PUMP CUCCHI P1.54 P1.54 4-1st STAGE WATER PUMP CUCCHI P1.54 P1.55 5 - CASTING BFC12.029 BFC12.029 6 - HYDRAULIC SHOCK ABSORBER GR.MAR.01/1 GR.MAR.01/1 7 - PUMP BRACKET BFC12.021/001 BFC12.021/001 8 - WIELAND CONNECTOR (MALE) 4 PIN E2.22 E2.22 9 - WIELAND CONNECTOR (FEMALE) 4 PIN E2.23 E2.23 10 - WATER PRESSURE SWITCH HUBA 605 Q1.18/2 Q1.18/2 11 - RELAY SOCKET FINDER R9.05 R9.05 12 - RELAY FINDER R7.11 R7.11 13 - CONTACTOR LOVATO (No. 2) R6.03/1 R6.03/1 14 - THERMAL RELAY LOVATO (No. 2) R5.10/8 R5.10/8 15 - FUSE HOLDER FUSIT E8.02/2 E8.02/2 16 - FUSE FUSIT E8.04/1 E8.04/1 17 - MAIN SWITCH R10.01 R10.01 18 - LOCK-OUT LAMP RED E15.09 E15.09 19-1st STAGE FLAME LAMP GREEN E15.07/2 E15.07/2 20-2nd STAGE FLAME LAMP GREEN E15.07/2 E15.07/2 pag.11

Ecoflam La ECOFLAM S.p.A. S.p.A reserves si riserva the right il diritto to make di apportare any modifications ai prodotti quelle to its products modifiche it che deems riterrà necessary necessarie or o beneficial utili, senza without pregiudicarne altering le their caratteristiche fundamental principali. characteristics. Ecoflam S.p.A. via Roma, 64-31023 RESANA (TV) - Italy - tel. 0423/715345 r.a. - telex 411357 ECOFLA I - telefax 0423/715444