Waste & Recycling Container, Storage and Vehicle Access Requirements



Similar documents
REFUSE AND RECYCLING STORAGE REQUIREMENTS

Waste Management. GUIDANCE NOTES FOR DEVELOPERS AND LANDLORDS ON THE STORAGE & COLLECTION OF DOMESTIC REFUSE AND RECYCLING (December 2012)

GD 04. Waste Storage and Collection Guidance for New Developments. Version: 2.00

Household waste & recycling storage requirements

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY.

WASTE AND RECYCLING STORAGE REQUIREMENTS

Appendix 6 Storage and Collection of Waste and Recycling

Refuse & Recycling Storage Design Guide

Policy document on the provision of waste & recycling collection and storage facilities. Includes both domestic and commercial premises

WAVERLEY BOROUGH COUNCIL ENVIRONMENTAL SERVICES DEPARTMENT WASTE AND RECYCLING

WASTE & RECYCLING STORAGE AND COLLECTION REQUIREMENTS

part 9 waste management

GUIDANCE FOR FUTURE PLANNING PROPOSALS AND THEIR IMPACT ON WASTE VEHICLES SOUTH AND VALE

Waste and recycling requirements for new residential developments in Medway

Developer Guidance Note: Provision of Waste and Recycling Collection and Storage Facilities

Waste management guidance notes for residential developments

WASTE STORAGE AND COLLECTION

WASTE STORAGE AND COLLECTION GUIDANCE FOR NEW DEVELOPMENTS

Refuse and recycling storage guidance

Forest of Dean District Council. Requirements for refuse and recycling provision at new developments

Refuse and Recycling Advice note For Developers. September 2015

Recycling and Waste: Advice note for developers 2015

Supplementary Planning Guidance WASTE COLLECTION AND STORAGE FACILITIES

Provision of Household Waste & Recycling Service

Planning Technical Advice Note: Waste bin storage and access requirements for new and change of use developments

Waste Storage and Collection Guidance for new Developments

Version Decision Number Adoption Date History 1 20\ /02/10 Adopted 2 3 4

Waste and Recycling Storage and Collection Guidance for Houses, Flats, Houses of Multiple Occupancy, New Builds, and Conversions.

GUIDELINES FOR PREPARING A WASTE MANAGEMENT PLAN

Supplementary Guidance Stiùireadh Leasachail. Managing Waste in New Developments A Stiùireadh Sgudal ann an Leasachaidhean Ùra

Refuse and recycling storage for new dwellings Planning guidance. December 2013

Design requirements for residential properties recycling and waste management

LONDON BOROUGH OF BRENT. Waste and Recycling Storage and Collection Guidance for Residential Properties

Workplace Health, Safety & Welfare

CITY of richmond design ConsIderaTIons for CommerCIal ProPerTIes: recycling and garbage

ACCESS AUDIT OF WESTPORT HOUSE

Waste and Recycling: Collection and Storage Facilities. Guidance for developers, owners and occupiers

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

This document aims to inform developers and architects of Waste and Recycling Service requirements in the London Borough of Hounslow.

SHORT TERM RENTAL. Nationwide Service Centre Network. Driven By You, For You. Go Plant Ltd (Head Office)

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

How To Manage Waste In The Borough Of Newham

Premier Bodies Limited based in North Shropshire being 25 miles from Shrewsbury and 15 miles from Wrexham strategically located for easy access to

SPACE ALLOCATION AND ENCLOSURE DESIGN GUIDELINES FOR TRASH AND RECYCLING

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

Walking and Working Surface Checklist:

AMS 120. EFT Guest Card Terminal & Refund unit

THE UNIVERSITY OF EDINBURGH. ECA Evolution House.

Planning Advice Note. Waste and Recycling Provisions in New and Refurbished Residential Developments

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Spill Containment. Contents

Recycling Infrastructure Guidelines for UBC Buildings

Ministry of the Environment Decree on accessible building

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

How To Increase Vehicle Height Of A Tunnel In Daugherd Port

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

Meaco 30L and Meaco 40L dehumidifier instruction manual

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

LONDON ROAD SEVENOAKS

Rochdale Building Control Guide. Approved Document F Means of ventilation

New College. School Of Divinity.

INSTALLATION & USER INSTRUCTIONS

VEHICLE CROSSOVER INFORMATION PACK

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Wandsworth Local Plan Supplementary Planning Document. Refuse and recyclables in developments

Squash Court Design general points

LIMASA takes delivery of new waste collection fleet at Málaga football stadium

Disabled Access Guide

EZ-Steer Assisted Steering System

Integrated Waste Management Plan (IWMP) For Clover Clayville February 2011

DESIGN GUIDANCE NOTE: 11 PORCHES

Waste Services Collection Service

VOLVO WHEEL LOADERS BLOCK HANDLING

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings,

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

DELIVERY & SERVICING PLAN. REDWOOD PARTNERSHIP Consulting Engineers Transportation Planners

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

COMPACT & UTILITY TRACTOR LOADERS 235TLA I 240TLA I 250TLA I 110TL I 250TL I 615TL I 625TL

Development Design Guidelines for Source Separation of Solid Waste. Regional Official Plan Guidelines

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Design and Access Statement Earls Court Road London SW5 9RH

THE UNIVERSITY OF EDINBURGH. 16 Buccleuch Place.

House Design Tutorial

Skip and container safety in waste management and recycling

Innovative Hidden Storage Solutions

PREFERRED REQUIREMENTS: WATER SUPPLIES AND ACCESS FOR SUBDIVISIONS IN RURAL ZONES

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND. Committee CE-001 Parking Facilities DRAFT. Australian/New Zealand Standard

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Customer Service. At The Heart Of Our Business

Planning Information. Passenger and Freight Elevators.

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Standard Requirements for Cold Store Licence IMPORTANT

Transcription:

Waste & Recycling Container, Storage and Vehicle Access Requirements PLEASE NOTE: This information is intended to provide overview guidelines for University of Edinburgh staff and contractors only. Exact container requirements for new buildings and refurbishments must be confirmed prior to finalising any design specifications. Current vehicle access requirements corresponding to current container types in use in centrally managed UoE contracts are appended to this document and will be updated as and when necessary. Contents: page General Site requirements 1 Specific Container and Collection Vehicle requirements 1 Requirements for internal bin stores 4 Wheeled bin compactors 4 Appendicies 5 General Site Requirements Roads providing access to the building should have foundations and a hard-wearing surface capable of withstanding a fully laden refuse vehicle of 32 tonnes gross vehicle weight (GVW), with a maximum axle weight of 20 tonnes. Roads should have a minimum width of 5m and arranged so that the collection vehicle can continue mainly in a forward direction. If turning space is necessary, the road layout should permit a turning circle of 21.5m*, kerb to kerb. (*Required turning circle is larger for the 15.3cu.m. compactor should it be required). Any gates or arches on the vehicle route to the refuse/recycling storage area should give a minimum clearance of 3.72m width and 4.5m height. There should also be a water supply and a trapped gully to allow for regular cleansing, adequate lighting and sufficient space around to allow safe access by staff to all containers (and any bin compaction units where present). Surface of the service bay and between the service bay and the building should be rendered with a smooth continuous finish (a cobbled surface is unsuitable for any type of wheeled container). Space Requirements for Specific Containers in use The management of waste and recycling within the Academic and Support estate is carried out by Estates & Buildings. Within the Accommodation estate, waste and recycling are managed by Accommodation Services. Waste Management services are procured according to Public Procurement rules and the contractor for these services could change accordingly. It is therefore necessary to confirm with the relevant unit exactly which containers are suitable for the proposed building which you are dealing with prior to using the specific information below. Academic and Support Estate The main containers in use (and their volume) around the Academic and Support estate are: Compactors 10.7m 3. Ver: 1503 Page 1 of 5

Closed, secure walk-in containers (Ro-Ro s) 26.7m 3. Closed, secure skips 9.1m 3. Front-End Loader (FEL) 6.1m 3. Mobile, eurocart containers 1100-litre, 660-litre, 240-litre. Compactors Compactors have a large capacity and can achieve volume reductions of up to 4:1. This kind of container is suitable for use in premises where a significant volume of waste is likely to be produced, such as large offices, retail units and hotels as well as mixed developments. They are usually purchased outright by the Project. They require direct access by a skip or Ro-Ro vehicle. Additional length is required to that given below for the service bay to accommodate the collection vehicle. The University owns two main compactor types Avermann P10 and Phoenix (slightly smaller). P10 (10.7m 3 ) compactor Vehicle (Roll-on, Roll-off 4 axle) - see appendix for current vehicle specifications and access requirements. Compactor Dimensions - 4.375m (l) x 1.99m (w) x 2.46m (h) Service Bay Dimensions 6m (l) x 5m (w) x 5m (h) o Smooth, impervious, level surface o Minimum width of entrance to service bay: 4.0 metres. o Power Supply 3x400V, 50Hz (three-phase neutral & earth), CEE-connector 32A, commando plug connector suitable for external use. The power supply should terminate with an RCD box located within two metres of the compactor. Note: In developments where the service bay opens directly on to the street, the distance from the Closed, secure walk-in containers (Ro-Ro s) This container type tends to be used only for recyclate at the University in areas where very large volumes of recyclate are produced. Currently only 26.8m 3 roll-on, roll-off containers are in use. These containers are entered via a single hinged door to the back of the container (as per vehicle orientation on collection). Dimensions (of a 26.7m3 container) 6.1m (l) x 2.5m (w) x 2.4m (h). Service Bay Dimensions 9.5m (l) x 6m (w) x 5m (h). Vehicle (Roll-on, Roll-off) - see appendix for current vehicle specifications and access requirements. o Smooth, impervious, relatively level surface (low gradients can be acceptable but only along a particular orientation). o o Minimum width of entrance to service area: 4.0 metres. Sufficient space to the side to enable the door to be fully opened in order to be connected to a catch on the side of the contrainer. Waste & Recycling Container, Storage and Vehicle Access Requirements (Ver: 1503) Page 2 of 5

Important notes: This container type is not emptied on site. An empty container is brought and the full one taken away. The location must therefore allow for space in the vicinity for the empty container to be put down whilst the full one is removed. Not all sites suit this type of arrangement. In developments where the service bay opens directly on to the street, the distance from the Closed, secure skips 9.1m3. This container type tends to be used for large volume recyclate (dry) or general waste (wet). Dimensions (of a 9.1m3 container) 4.1m (l) x 1.9m (w) x 1.7m (h). Service Bay Dimensions 6.1m (l) x 4m (w) x 4.5m (h). Vehicle (Skip)- see appendix for current vehicle specifications and access requirements. o Smooth, impervious, relatively level surface (low gradients may be acceptable but only along a particular orientation). o Minimum width of entrance to service area: 4.0 metres. Important notes: This container type is not emptied on site. An empty container is brought and the full one taken away. The location must therefore allow for space in the vicinity for the empty container to be put down whilst the full one is removed. Not all sites suit this type of arrangement. In developments where the service bay opens directly on to the street, the distance from the Front End Loader (FEL) This container type is used for medium volume general waste (wet). Dimensions 2.14m (l) x 2.0m (w) x 2.14m (h). Vehicle (FEL) see appendix for current vehicle specifications and access requirements. o Additional 2.0m height required to open bins for normal use. o Smooth, impervious, level surface for storage. o Containers must sit at least 1m away from building walls and 0.5m away from any other container. o Containers are tipped on site and as a result have extra height requirements. Mobile, Eurocart containers various 1100-litre wheeled bins Dimensions 1.36m (l) x 1m (w = depth in this case) x 1.45m (h) Vehicle (trade refuse vehicle 3 axels) see appendix for current vehicle specifications and access requirements) o Additional 1.2m height required to open bins for normal use. o Smooth surface for wheeling with level surface for storage and through to point of uplift. Smaller capacity bins can be made available where necessary. Waste & Recycling Container, Storage and Vehicle Access Requirements (Ver: 1503) Page 3 of 5

Requirements for Internal Bin Storage areas Internal bin storage areas are suitable for wheeled bins of 1100-litres or smaller capacity only: a) A suitable cover or roof. b) At least one external wall. The walls to be constructed of impervious material. c) A double door of minimum width 1.6m. d) A water supply and a trapped gully to allow for regular cleansing. e) Adequate lighting. f) Means of natural ventilation (air bricks or louvers). g) A minimum headroom of 2.2 m. h) Sufficient space to allow access to all containers (and any bin compaction units where present. i) The floor surface should incorporate an integral coving to facilitate cleaning. j) A rubbing strip should be attached to the wall surfaces and doors to prevent scuffing. k) The total distance from the internal store room to the collection vehicle should be no greater than 25m. l) The floor must be level with the adjacent path or highway with a gradient of no more than 1.1 from storage site towards the collection vehicle. Wheeled Bin Compaction Units These compaction units are used with wheeled bins in areas where additional capacity is needed but where it is not possible to provide appropriate space for larger container types. These compactors can achieve volume reductions of up to 3:1. Adequate floor space is required (given in the table below) to allow for working space for the container. It is advisable to site the compactor undercover at ground floor level with close, level access to the collection point. Unit specifications: Bin Capacity (litres) 660 & 1100 Dimensions - 1.8m (w), 2.7m (l), 4.0m (working length), 2.5m (h) Floor area required - 7.2 m2 Power Supply 240 volts, 15 amp earthed socket Bin type: 1100 litre (see requirements for 1100-litre bins for additional information). If you require any further information, please contact Estates Waste Management, Estate Operations, 13 Infirmary Street, EH1 1LT. Tel: 0131 651 4287. Email: Waste@ed.ac.uk Prepared by: Fleur Ruckley, Waste & Environment Manager Date: this version (1503) April 2015 (original document - Jan 2008; last revision Jan 2013) File name: \EB15\...\Internal Policies, Guidance\1503Container-VehicleAccessReq.docx Waste & Recycling Container, Storage and Vehicle Access Requirements (Ver: 1503) Page 4 of 5

Appendix - Container and Vehicle Access Requirements The information appended here regarding vehicle access requirements is current at the time of preparing this document. It is intended to provide additional information to enable Design Teams and contractors to more accurately plan external waste storage requirements for Capital Projects. The onus is on the user to check with Estate Waste Management as to whether container types in use or vehicles being used to service these containers has changed (or is likely to in the near future). Skip vehicle specification and requirements (last updated April 2015) Gross Vehicle Weight 18,000kg Number of axels 2 Height 4000mm truck height / 4500 mm full height loading Length 6700mm vehicle length / 15,000mm operating length when collecting Ro-Ro vehicle specification and requirements (last updated April 2015) Gross Vehicle Weight 32,000kg Number of axels 2 Height 3850mm truck height / 4950 mm full height loading Length 9140mm vehicle length / 20,000mm operating length when collecting FEL vehicle specification and requirements (last updated April 2015) Gross Vehicle Weight 32,000kg Number of axels 4 Height 4500mm truck height / 5500mm full height top loader Length 12000mm Eurocart vehicle specification and requirements (last updated April 2015) Gross Vehicle Weight 26,000kg Width 2200mm truck body / 2650 including mirrors Height 3500mm truck height Length 8300mm vehicle length / 12300mm operating length when collecting Glass collection vehicle specification and requirements (last updated April 2015) Gross Vehicle Weight 11,000kg Width 2200mm truck body / 2650 including mirrors Height 3030mm truck height / 4300mm full height top loader Length 7500mm Turning Circle wheel-cut angle 49.5 degrees Waste & Recycling Container, Storage and Vehicle Access Requirements (Ver: 1503) Page 5 of 5