Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Similar documents
Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

How To Make A Data Center More Efficient

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DIGITUS Network & Server Cabinets. UNIQUE Series

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Protecting Our Information, Protecting Our Resources

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

Virginia Tech. Background. Case Summary. Results

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

RiMatrix S Make easy.

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

Cabinet V800 V800 CABINETS

HERZ-Thermal Actuators

Protecting The Critical IT Infrastructure of the United States

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

ECOCIAT. Domestic hot water heat recovery unit

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

How To Run A Data Center Efficiently

CRAC Precision climate control units for data centres

How To Save Energy On A Power Supply

Enterprise Remote Monitoring

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Power Distribution Considerations for Data Center Racks

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

2 Rittal Micro Data Centre

BLADE S-MAX Cabinet for Blade Server

DCF Optimized Rack System

Incubator with mechanical convection

How To Make A Fronius Cl Power Inverter

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

Small Data / Telecommunications Room on Slab Floor

NetSure DC Power Solutions with esure High-Efficiency Technology. DC Power for Business-Critical Continuity TM

Rittal Liquid Cooling Series

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

How To Build A T7 Rack For Information Technology

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

NetSure DC Power Solutions with esure High-Efficiency Technology

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

How To Improve Energy Efficiency In Data Center Management

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

High Density Cooling Solutions

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Datasheet FUJITSU Storage ETERNUS LT250 TAPE LIBRARY

Great Lakes Data Room Case Study

SERVER ROOM CABINET INSTALLATION CONCEPTS

Electric Flow Boiler

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Access Server Rack Cabinet Compatibility Guide

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

T5000 T000 LCD Digital Fan Coil Thermostat

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Fujitsu PRIMERGY BX600 S3 Blade Server

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Transcription:

Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems

Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes: new server technologies, changing IT-requirements and economic pressures mean that modifications form an inevitable part of day-today life in data centers. At the same time, rapid technological advances combined with continuously rising expectations for data center technology place existing infrastructures under further pressure. It is not always possible to build from scratch in order to meet these increased demands. In most cases, planning must be restricted within the confines of existing structures. Themigrationofnewserverswithinexisting data centers places great demands on existing infrastructures. In most cases, technical limitations are met and overcome through retrofitting. However, even if it is possible to adjust the network infrastructure and electrical supply at reasonable operating expense, current air conditioning technology reaches its limitations very quickly. Overheating within such installations is thus inevitable. Hotspots within the entire data center inevitably lead to the slow-down of data processors until complete shutdown. CoolAdd represents the ideal retrofit solution for data centers and ITrooms. It safeguards against the risk of hotspots and helps to avoid overheating of the server racks. A special feature of this quick and highly effective solution is that the existing server rack remains within the data center. In addition, the entire wiring may remain as it is, without the need for any alterations! Therefore, CoolAdd is an easy-to-use replacement for the server's rear door. It operates on the following technical principle: safe cooling of the servers' emitted air temperature in order to meet the required supply air temperature. CoolAdd consists of three basic components: - connection adaptor for the existing server rack - air-water-heat-exchanger (fixed to the rack) - backdoor with fans The server s thermal power loss is transferred into the data center s cold water installation by means of the airwater-heat-exchanger. Powerful fans ensure optimum cooling-out. Convenient installation: CoolAdd may be mounted on all currently available server racks. The installation is mounted onto an adaptor frame. As a second step, the heat-exchanger is fixed onto the existing rack. It is recommended that the cold water supply is connected through the base. Fans are positioned at the door in order to maintain perfect access to the entire installation within the rack. CoolAdd - the quick and economic solution against hotspots in data centers and IT-rooms; the immediate aid for securing business-critical processes (Business-Critical Continuity ).

Features Installation with adapter kit Adjustment of just a few parts Thermostatic shuttle valve for regulating cooling power Manual fan speed setting Individual fan monitoring Individual fan protection Installation with adapter kit Shuttle valve for regulating cooling power Heat exchanger is firmly connected with the existing rack (pipes and other connections are not accessible in the data centre) Redundant n+1 fan set-up Benefits CoolAdd can be used with all current rack types Server rack remains unchanged Slim design heat exchanger (85 mm) Access to components is always maintained Water-carrying components are safely shielded from the rack Existing racks can continue to be used Existing cabling remains Quick installation Just a few CoolAdd components have to be adjusted Cools the server s warm exhaust air side Access to all built-in components always maintained Relieves the data centre s thermal management system Cools an additional 8,000 watts

Shouldered thermostat relay with extensible component (without auxiliary power) Optimal fans, including casings Fan failure display/ four speed levels Robust and safe 3 pt.-interlock Cooling capacity Width Height Depth Weight Water content Fans Air-Volume flow 8kW 600 mm 700 mm 800 mm 2000 mm or 2200 mm 160 mm 41 kg up to 47 kg 1.6 l 4 Fans 2500 m 3 /h State: 02/2008 Spreadchilledwater: 14/20 C Exhaust temperature after heat exchanger: 22 C Connection heat exchanger: 3/4 male thread Cooling water volume flow: 1.15 m 3 /h Pressure loss (heat exchanger): 400 mbar Max. operating pressure heat exchanger: 10 bar Max. absolute humidity on site: 8 g / kg Standard colours: RAL 7021 (black grey) Elt. Connection (fans / fan control): 230 V / 50 Hz 525-725 W Protection class: IP 20

www.knuerr.com Knürr CoolAdd setting standards Knürr s CoolAdd sets new standards when it comes to cost-effectiveness as an ideal upgrade solution for all current server racks in small IT rooms or large-scale data centers! Knürr is also a guarantor for system solutions in IT and network technology with products of an exceptional level of quality. Innovative rack platforms, proven-inpractice thermal management and tailor-made power supplies meet the future-proof requirements of the data center, telecommunications and network technology. Adaptive Architecture The solution for securing business-critical processes. Primary cooling circuit Secondary cooling circuit CoolTrans CoolAdd

Emerson Network Power is a consistent global technology leader and recognised expert that helps to secure business-critical processes, and by doing so contributes to a business-critical continuity. A series of the most diverse applications, including the tried, tested and proven Knürr rack system solutions and the thermal management connected with them, ensure the required network stability with the highest technological adaptability at the same time. Knürr AG Global Headquarters Mariakirchener Straße 38 94424 Arnstorf Germany Tel. +49 (0) 87 23 / 27-0 Fax +49 (0) 87 23 / 27-154 info@knuerr.com Knürr system solutions in the world of information and network technology are part of an adaptive Emerson Network Power architecture, which flexibly adjusts to all changes concerning security/safety, highdensity and all associated capacities. Companies profit in a sustainable and long-term way from the high IT availability, operative flexibility and impressive reduction in investment and operating costs. Knürr AG is recognised around the world as one of the leading developers, manufacturers and distributors of rack and enclosure platforms in the indoor and outdoor area, including all relevant active/passive components of 19 structures and the technologies connected with them. Knürr is certified in accordance with EN ISO 9001 and the EN ISO 14001 standard. Knürr s quality management continuously guarantees the highest level of quality in all areas of the company. Emerson Network Power The global leader in enabling business-critical continuity AC Power Systems Connectivity DC Power Systems Embedded Power Integrated Cabinet Solutions Outside Plant PowerSwitching&Controls Precision Cooling Services Local contacts, please visit: www.knuerr.com While every precaution has been taken to ensure accuracy and completeness in this literature, Knürr AG assumes no responsibility, and disclaims all liability for damage resulting from use of this information or for any errors or omissions. 2008 Knürr AG. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Knürr and the Knürr logo are registered trademarks of Knürr AG. EmersonNetworkPower.com Site Monitoring Surge&SignalProtection Rack & Enclosure Systems Knürr logo, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2008 Emerson Electric Co. 09.997.817.9 5MI308 Printed in Germany Idea, Graphic, Editor: Gropp/Huber Specification subjects to change without notice.