Ultra-Filter. Compressed Air Filter. DF Series



Similar documents
Innovative to the Core

How To Remove A Large Particle From A Large Tank

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Technical Data Sheet Page 1 of 5

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Ultra-Web High Efficiency Nanofiber Filters

Kompressoren. Adsorption Dryer AD

Compressed Air Filters

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

DIESEL FUEL CONDITIONING

Atlas Copco Quality Air Solutions. Compressed Air Filters

Medical Air Systems: Scroll

ThermoSorb Desiccant Dryers

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Adsorption air dryers ADS 1 215

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

ultrafilter HEATLESS HL Adsorption Dryer

CSD WATER REMOVAL FILTERS FOR DIESEL

Pro Dry Heatless dessiccant compressed air dryers

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Ingersoll Rand. Heat-Of-Compression Air Dryers

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

ETC -SV. Class 0 oil-free compressed air through catalysis

NORMAN FILTER COMPANY PRODUCT OVERVIEW

REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL

REFRIGERATED COMPRESSED AIR DRYERS

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers

Downflo workstation DuSt ColleCtorS

Refrigeration Compressed Air Dryer Buran Ultrapulse

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

CONDENSATE MANAGEMENT

Ultipleat High Flow Filter System

Model 111 Mass Flow Instruments

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

15/40/80CN Series Coreless Medium Pressure Filters

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

How To Order A Direct Flow Air Cleaner

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

6 Crankcase Ventilation

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

In-Line Filters and Coalescers with Automatic Drains

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Norgren Air Preparation Products and Accessories

Meeting Your Compressed Air Treatment Needs

EnviroAire Series. 15kW 110kW Oil-Less Rotary Screw Compressors ILLESS

How To Make A Fuel Manager Filter/Separator

Kompressoren. Oil Water Separators OWS

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Vacuum Dehydration Oil Purification System (VDOPS)

15/40/80CN Series Medium Pressure Filters

Rotary screw compressors kw 5,5 7, , bar MODULO

ROTARY SCREW COMPRESSOR. RMD kw

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Filter Housing SG Standard

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering

Cartridge Filter Application Notes

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

Screw Compressors 11-22kW

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

Element D Services Plumbing

Desiccant Air Dryers Heatless, Heated and Heated Blower

Air Treatment Solutions

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Dryaire Desiccant System

Medical Air Plant. uair Series (7-145 l/s / cfm)

HIGH PERFORMANCE FILTERS AND ELEMENTS

PVS Series - Models 185, 600, 1200, 1800 and 2700

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Compressed Air Filters KAESER FILTER Flow rate 0.60 to m³/min

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008

How To Clean Water From An Ammonia Refrigeration System

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Natural Gas Solutions. Applications, Features, Specifi cations

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

MANN+HUMMEL filters for compressors

CUNO High Flow Filtration Systems

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Your oil can be saved!! Even when water is mixed

Filters for the Natural Gas Industry. Bulletin NG/USA Rev A

Compressed air conditioning

LEED FOR BUILDING DESIGN AND CONSTRUCTION (LEED BD+C) v4 DOCUMENTATION LETTER FOR UNITED STATES OF AMERICA

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Keeping contamination under control.

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

Transcription:

Ultra-Filter DF Series

ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing, and customer support network to meet the most demanding applications. With over 30 years of expertise in compressed air filtration and separation technologies, Donaldson manufactures a complete line of drying and filtration equipment using innovative designs that focus on energy efficient operation and reliable performance. Our patent pending Donaldson Ultra-Filter compressed air filter reduces pressure loss by 50%, increases filtration efficiency, and is easy to install and use. The Donaldson Ultra-Filter (DF) Filters are designed for high quality filtration of compressed air or gas in a wide range of applications. The total filter design concept of the filter combines high performance, efficiency, ease of use, flexibility, and safety. Features & Benefits Reduced pressure drop by 50% uses less energy consumption. Coalescing filter elements performance data validated according to ISO 12500-1 assuring reliable achievement of compressed air quality according to ISO 8573-1. Filter element can be removed together with filter bowl, reducing overall installation height requirements. Changing the code clip inside the filter bowl changes the flow direction through the element so that the filter can be either used as a coalescing filter (inside to outside flow) or a particulate filter (outside to inside flow). The integrated differential pressure indicator can be easily rotated in the filter head. The bayonet lock ensures that the filter cannot be opened under pressure for increased safety. Filter housings are immersion-coated ensuring long-term protection against corrosion. Ultra-Filter DF Series Superplus Version Nine sizes, six filter element types, and available options perfectly meet virtually all industrial air purification application requirements. * For more information on the Donaldson Ultra-Filter elements, please refer to respective brochures.

qüé=kéï=aéëáöå=ô=fååçî~íáîé=íç=íüé=`çêé Unrivaled high performance. Donaldson Ultra-Filter was developed on the basis of worldwide experiences and innovative design resulting in a highly efficient and economic filtration concept. Flow-optimized filter design provides minimum pressure loss. Innovative filtration technology ensures high separation efficiency. Total filter design concept delivers unrivaled efficiency. Flow Optimized Airflow Computer-aided simulation was the basis for the turbulence-free design with optimized airflow through the filter housing and into the element. This ensures low pressure losses. The core of each filtration system is the filter element. Careful selection of filtration media, optimized pleating, and advanced production technology, produce a reduction of pressure loss by 50% while concurrently increasing separation efficiency. The element coalescing drainage layer is fixed in place by the outer support sleeve ensuring a constant cross-section between the element and housing at all times. Unrivaled Efficiency. The economic efficiency is clearly indicated by the reduction in differential pressure. A 3.0 PSI lower differential pressure over 8000 operating hours at 600 scfm saves $1,452 per year (based on 100 psig operating pressure, 120 kw installed power and $0.08/kWh.) This practical example shows that the investment in optimizing the compressed air system rapidly pays for itself. Energy Cost Savings Through Reduction of Differential Pressure $2,500 Annual Energy Cost Savings $2,000 $1,500 $1,000 $500 Example: 600 scfm, 3.0 psi less pressure loss, $1,452 savings per year. 4.5 psi less dp 3.0 psi less dp 1.5 psi less dp $0 50 100 150 200 250 300 350 400 450 500 550 600 650 Flow Rate in scfm 1

qüé=kéï=oéîçäìíáçå=ô=båéêöó=p~îáåöë Energy Savings. Further energy savings are achieved by the timely replacement of used filter elements. The most economic time for filter changeout is determined by the Economizer that continuously measures the differential pressure. An integrated microprocessor evaluates the measurement data and compares the higher energy costs caused by pressure loss with the costs of a new filter element. The most cost-effective element replacement time is calculated and LEDs then signal that filter changeout is necessary. Economizer Operating Costs Total costs (energy plus elements) Kmin Economizer Element costs Energy costs Optimal exchange time Operating time Unrivaled Ease of Use. The new Donaldson Ultra-Filter is unrivaled in its ease of use both during installation and filter element replacement. The filter bowl is rotated slightly via a bayonet lock and can be removed together with the filter element requiring only an inch of ground clearance. The integrated condensate drain allows new element changeout without disconnecting power and condensate drains. The cover with integrated differential pressure displays can be rotated so that the display stays visible from the selected side. 2

qüé=kéï=cäéñáäáäáíó=ô=b~ëé=çñ=rëé Unrivaled Flexibility. All filters can be used either as coalescing filters (flow through the element from the inside to the outside) or as particulate filters (outside to inside flow). If the requirements change, the filter head does not need to be rotated. Changing the coding clip inside the filter bowl allows the filter element to be rotated and changes the flow direction. The coalescing filter becomes a particulate filter in seconds and vice versa. Optional wall supports are available on request for flexible wall mounting. The telescopic design of the support provides broad adjustability. A series of filters with different element types maybe installed with connection adapters. The Ultra-Filter is simple to mount and fits into the smallest space. With nine sizes, the new Donaldson Ultra-Filter covers the performance range from 20 to 647 scfm flow rate corresponding to conventional compressor capacities between 2 and 120 kw. The Ultra-Filter compressed air filter is available in two models: Standard with float condensate drain and Econometer. Superplus with UFM-T zero air-loss condensate drain and Economizer. Coalescing, particulate, and activated carbon elements are available in different grades to fit your application needs. Unrivaled Safety. The bayonet lock ensures that the filter cannot be operated under pressure. Lock and unlock symbols on the filter head clearly indicates the filter s seal. 3

Dimensions & Specifications Dimensions (inches) Standard 2 Superplus 2 Capacity 1 Connection Element Standard Superplus Weight Weight Model (scfm) (inches FNPT) Size Qty. Height Width Height Width (lbs) (lbs) DF 0035 20 1/4 0035 1 7.5 3.5 16 3.5 1 3 DF 0070 41 3/8 0070 1 11.5 4.5 18 4.5 2 4 DF 0120 70 1/2 0120 1 13.5 4.5 20 4.5 2 4 DF 0210 123 3/4 0210 1 14.5 6 21 6 5 6 DF 0320 188 1 0320 1 17.5 6 24 6 5 7 DF 0450 264 1-1/4 0450 1 23 7.5 29 7.5 12 7 DF 0600 353 1-1/2 0600 1 23 7.5 31 7.5 12 7 DF 0750 441 2 0750 1 23 7.5 31 7.5 12 7 DF 1100 647 2 1100 1 30 7.5 35 7.5 16 15 1 Capacity based on 100 psig inlet pressure. 2 Without filter element. Materials Filter Housing Aluminum die cast Maximum Operating Inlet Pressure: 250 psig Econometer Float Drain Polymer Polymer / aluminum mold cast (Standard) Aluminum, glass fiber reinforced polymer (Superplus) Maximum Operating Inlet Temperature: 150 F (65 C) Gaskets Viton Viton is a registered trademark of DuPont Performance Elastomers L.L.C. Element Data Type Initial Dp (psid) Residual Oil Content Particle Retention Rate S Coalescing Filter 1.45 <0.01 ppm 1 99.99998% on 0.01 micron particles M Coalescing Filter 1.3 1 ppm 1 99.9999% on 0.01 micron particles V Coalescence Filter 0.7 1 ppm 1 90% on ISO fine dust P Particulate Filter 0.7 100% 2 N/A B Particulate Filter 0.7 100% 2 N/A A Activated Carbon Filter 1.45 <0.003 ppm 1 N/A 1 Based on inlet concentration of 3 ppm. 2 Related to the pore size. 4

Capacity Correction Factors The published standard capacities for compressed air Ultra-Filter DF Series filters are based on 100 psig inlet pressure and 100 F inlet temperature. When these conditions vary, a given Ultra-Filter DF Series filter will be able to purify either more or less compressed air than its standard capacity. There are two ways in which this information can be used. The first is to start with a specific Ultra-Filter DF Series filter size and recalculate its capacity based on the known operating conditions using the correction factors given below. The other, with a given set of operating conditions, is to select the proper Ultra-Filter DF Series filter size based on applying the correction factors to the flow rate. Examples based on applying the correction factors are shown below. Capacity correction factors for differing system air pressure (C1) System Pressure (psig) 15 30 45 60 75 90 100 115 130 150 160 175 190 200 220 250 Correction Factor 0.26 0.39 0.52 0.65 0.78 0.91 1 1.13 1.26 1.44 1.52 1.65 1.78 1.87 2.05 2.31 Capacity correction factors for differing system air temperature (C2) System Temperature ( F) -20 0 20 40 60 80 100 120 140 150 Correction Factor 1.52 1.41 1.31 1.22 1.14 1.07 1 0.94 0.88 0.86 To Size the Ultra-Filter Model Capacity for Actual Conditions Adjusted Capacity = scfm x C1 x C2 To calculate the capacity of a given Ultra-Filter DF Series filter based on nonstandard operating conditions, multiply the standard capacity by the appropriate correction factor(s). EXAMPLE: Ultra-Filter DF Series Model: DF 0210 MK Standard Capacity: 123 scfm Actual Operating Conditions: 75 psig inlet pressure: C1 = 0.78 120 F inlet temperature: C2 = 0.94 Adjusted Capacity = 123 scfm x 0.78 x 0.94 = 90 scfm To Select the Ultra-Filter Model for Actual Conditions Adjusted Capacity = scfm/c1/c2 To choose a Ultra-Filter DF Series filter based on a given flow at non-standard operating conditions, divide the given flow by the appropriate correction factor(s). EXAMPLE: Given Flow: 500 scfm Actual Operating Conditions: 130 psig inlet pressure: C1 = 1.26 60 F inlet temperature: C2 = 1.14 Adjusted Capacity = 500 scfm /1.26/1.14 = Selected Ultra-Filter Model = 348 scfm DF 0600 MK 5

RIGHT TOWER DRYING LEFT TOWER REGENERATING Trust Donaldson Compressed Air & Gas to deliver a complete range of compressed air purification solutions that improve air quality throughout your plant from the compressor room to all points of use. With over 30 years of expertise in compressed air filtration and separation, Donaldson manufactures a complete line of drying and filtration equipment using innovative designs that focus on energy efficient operation and reliable performance. Donaldson has built a comprehensive engineering, manufacturing, and customer support network to meet the most demanding applications. Leading Technology Engineered Solutions Knowledgeable Service Prefilter Afterfilter Drain Valve 550 engineers worldwide More than 500 patents held by Donaldson employees Custom designed solutions Total system solutions Air capacities from 3 to 50,000 + scfm High pressure systems up to 10,000 psig Broad range of innovative filters and dryers Ready-to-ship filters and dryers within 48 hours Technical expertise and support açå~äçëçå=`çãé~åói=fååk `çãéêéëëéç=^áê=c=d~ë mklk=_çñ=novv jáååé~éçäáëi=jk RRQQMJNOVV=rKpK^K qéä UMMKRQPKPSPQ=Erp^F qéä UMMKPQPKPSPV=EïáíÜáå=jÉñáÅçF c~ñ TTMJQQUJPURQ ÅçãéêÉëëÉÇ~áê]ã~áäKÇçå~äÇëçåKÅçã ïïïkççå~äçëçåkåçã «=OMMT=açå~äÇëçå=`çKI=fåÅK mêáåíéç=áå=rkpk^k=çå=êéåóåäéç=é~ééê _ìääéíáå=kçk=rcp_mnqm=räíê~jcáäíéê=nnjmt