Access Control Interface Module D9210C. Program Entry Guide



Similar documents
$FFHVV&RQWURO6WDUWHU.LW

D7024 Fire Alarm Control Panels Software Version V2.06

Intelliguard 5800/5900/5924. Application Guide

Complete Security One Powerful Solution. GV4 Series integrated security, fire and access control panels D7212GV4, D7412GV4, D9412GV4

Security System Owner s Manual

Solution-16 Operators Manual ISSUE 1.60

D9412GV3/D7412GV3 v8.11 and Higher

Users Guide to Keypad Functions

D1260/D1260B. Keypad. National Security Systems Inc (800) Owner's Manual

Bosch Security Systems, Inc. Products Daylight Saving Time Adjustment October 29, 2007

ICP-CC488. Installation Guide ICP-CC488 Control Panel

ICP-CP500. User's Guide ICP-CP500 Codepads

PRT-CTRL-SE. Protege System Controller Reference Manual

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

IDS X-Series User Manual D Issued July 2012

Security System. User's Guide. Keypad

VR8. User Guide Intruder Alarm System

ISW-D8125CW-V2. Installation and Operation Guide. Inovonics Echostream Interface Module

AMAX 2100 / 3000 / en User Guide

Solution 16 plus. User Guide Security System

Solution 862 Operators Manual. Issue 1.00

Program Entry Guide. Control Panels

Contact ID Event Definition Codes

Solution 6000 Security Systems

Using triggers and actions

Solution 880 Operators Manual ISSUE 1.10

Ademco Vista-20P/First Alert FA-168C Basic Commands

NetworX TM NX-8E Alarm Panel. Application Note. NetworX NX-8E. 1.0 The NetworX NX-8E Alarm Panel

FDX Spider ALARM SYSTEM SHORT FORM USER GUIDE V1.6. SyxthSense Ltd

HAI Access Control. The HAI Access Control Card Reader can be used for:

D287/D288/D292/D293A/D293E

User s Information Guide R1A

Contact ID Codes. UNDEFINED DSC CONTACT ID CODE 104 RESTORE Zone Test/Misc. DSC CID RESTORE. 103 TECHNICIAN Unknown Test/Misc.

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

Using your LED Plus keypad

System Integration Software

Contact ID as of 2/2/2015

DC-8706K Auto Dial Alarm System

Access to the Lift Data Menu is via The Challenger User Menu option - Program Door Data.

Integra32. Integrated Alarm Monitoring and Access Control USER MANUAL

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

User Guide for the DS7060 Control/Communicator

Using Your. Security System With Icon Keypad S5020, S5021, S5022

The Challenger Version 8 User Guide

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response

Embedded Web Server. User Guide. General usage guide lines to the ISONAS Embedded Web Server available on all ISONAS PowerNet reader-controllers

SCORPION. micron security products

Understanding Access Control

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

ABUS WIRELESS ALARM SYSTEM

Control/Communicator Installation Manual

SECTION DETECTION AND ALARM

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

Control Panels B5512/B4512. en Program Entry Guide

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Tradition of quality and innovation

Solution-16 Operators Manual ISSUE 1.40

Access Control & Burglar Alarm Integration with KT-300

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

APR-PRT3 Printer Module: C-Bus Programming Instructions

D9412GV3/D7412GV3. Approved Applications Compliance Guide. Control Panels

How To Set Off An Alarm On A Car With A Car Alarm On It

VEHICLE SECURITY SYSTEM G25/G20

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

ELECTRONIC ENGINEERING LTD. PowerWave zone Control panel Communicator. User s Operating and Programming Guide. Version: 6.

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

CONTENTS 4. HOW TO UNSET THE PANEL...7

Volume. EverAccess. User s Manual

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

Honeywell s WIN PAK SE 2.0 / WIN PAK PE 2.0 Access Control System Guide Specifications in CSI Format SECTION

Advisor Master Programming Guide

Challenger Version 8 Basic Alarm System.

PRT3 Printer Module: ASCII Protocol Programming Instructions

Doc 10. UTM Standards: Card Access Security System

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Lynx Touch L5100 Technical Training. Z-Wave Setup

Using Your. Security System. With LED Keypad S5030, S5031, S5032

616, 626, 636 & 646 Keypads

Access Control Unit User s Guide

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

How To Set A Timer On A Gg System

AC-115 Compact Networked Single Door Controller. Installation and User Manual

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Remote Security Control

Logging and SNMP Trap Notification Of Events. Isonas Access Control System. Release 12 June 2007

FIRE DETECTION Note: Your installer must enable the fire detection portion of this equipment before it becomes functional.

National Security Systems Inc (800) Security System User's Guide

OnGuard Online User Guide

VOCALISER USER INSTRUCTIONS. Pyronix Ltd OCTOBER RINS113 Issue 2

Fire System. User's Guide

Destiny Destiny Owners Manual

Application Notes Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.

Car Alarm Series 2 B 2 Buttons

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

GV-AS Controller. Installation Guide

PK5500 v1.1 Installation Instructions

Transcription:

Access Control Interface Module D9210C en Program Entry Guide

Access Control Interface Module Table of Contents en 3 Table of Contents 1 Trademarks 4 2 Door Profile 5 3 Strike Profile 9 4 Event Profile 12 4.1 tes 14 5 Program Record Sheets 15 5.1 Profiles 16 5.1.1 Door Profiles 16 5.1.2 Strike Profiles 16 5.1.3 Event Profiles 16 Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

4 en Trademarks Access Control Interface Module 1 Trademarks About This Document This document describes the parameters available to the security panel for programming the D9210C Access Control Interface. For a description of the theory of operation and the actual operation of the unit, please refer to the D9210C Operation and Installation Guide (P/N: F01U215244). References made to the D9412 Family will reflect the following product offerings: D9412GV4, D9412GV3, D9412GV2, D9412G, D9412. References made to the D7412 Family will reflect the following product offerings: D7412GV4, D7412GV3, D7412GV2, D7412G, D7412. This document follows the organization of the RADXAXS handler in the D5200 Programmer (for GV3 Series v8.0x, GV2 Series, and G Series Control Panels) or RPS (Remote Programming Software). Use the ACCESS Control Interface Module Program Record Sheet (P/N: F01U201528) to record your choices prior to programming the device. Each programming section, program item, and its page number are listed in the table of contents on the following page. Throughout this document, programming prompts are shown in bold italic letters when they are used in a sentence. For example, Door # is the first programming prompt in the DOOR PROFILE section of the program. Reference to handlers, modules, categories and sections of the program are shown in italic, capital letters. For a more complete understanding of the panel and the D9210C Access Control Interface, read the following in addition to this program entry guide: D9210C Operation and Installation Guide (P/N: F01U215244) Security System Owner s Manual Security System User Guide Other Lettering Conventions used in this document D6600 Security Receiver and local printer reports are shown in typewriter -style letters. For example: ACCESS GRANTED indicates the report sent when the Access Control Interface detects a valid card read. Generally, words shown in all capital letters with brackets indicate command center displays and command center keys. For example, [ESC] is a key on the command center. Depending on the context of the sentence, all capital letters may also indicate a recommended programming selection. Reading Bosch Security Systems, Inc. Product Date Codes For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http:// www.boschsecurity.com/datecodes/. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Door Profile en 5 2 Door Profile This programming category is used to: Assign an area which also activates the interface module. Assign a point to the door. Program the door state to change when the arm state changes. Allow for the strike relay to activate upon a fire alarm. Door # 1 Selections 1-8 Enter the number of the door you are about to program. The D9412 Family supports 8 doors; the D7412 Family supports 2 doors. D# Entry Area # Blank Blank, 1-8 Assign an area to the door controller. This entry allows the D9210C to be polled activating communication to the panel. This also is the area a user will exit when initiating a Request to Exit [REX]. 1-8 The area assigned to the door controller to which the reader will allow access. Blank Door controller will not function. All SDI devices, regardless of area assigned, will report to Area 1, Account 1 by default upon SDI failure. If an interface module becomes disconnected, SDI Fail ## and MISSING POINT ### events will be created. 9210 NOT READY will appear at this command center when you press the [ENTER] key if the interface module is not programmed with a D# Entry Area. D# CC# Scope Blank Blank, 1-8 Enter the Command Center number [CC#] which determines the scope of the user ID s disarming rights. Areas will disarm on the basis of this Command Center s scope and the Authority Level of the user. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

6 en Door Profile Access Control Interface Module 1-8 This CC# Scope determines disarming rights. The user s access level in conjunction with the CC # Scope will determine which areas will be disarmed. Blank Only the area assigned to the D# Entry Area will disarm for this door. D# Door Point Blank Blank, 1-127, 129-247 Enter the point number that will be assigned to this door. This point cannot be used for any other point assignments. Door Points must be programmed as Perimeter Points. If a 24 hour point type is required for the Door Point, you may use a Perimeter Point Type with a Point Response of 9 - C. Also, the Debounce Count must be set to 4 in Point Assignments. 1-127, 129-247 The point number assigned to this door. Points 128 and 248 are reserved by the panel for internal use. Blank There is no point number assigned to this door. When assigning points 1to 8 (panel zones), the end of line resistors must be removed from the panel Do not enable any POPIT points (or OctoPOPIT points) sharing the same point number as the Door Point. Failure to do so will result in Extra Point trouble conditions upon reboot. D# Interlock Point Blank Blank, 1-127, 129-247 Enter the interlock point number. This point, when faulted, will prevent the door controller from allowing access upon a valid ID read or door request. Do not assign this point as a door point to another door point. You may assign it to another controller thereby having one interlock point prevent multiple controllers from activating. 1-127, 129-247 The point number assigned to this door. Points 128 and 248 are reserved by the panel for internal use. Blank There is no point number assigned to this door. The interlock point will be considered in a normal state if it is bypassed swinger bypassed or forced armed. This will result in normal operation of access even if the door is left open. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Door Profile en 7 D# Auto Door? Use this program item to unlock the door (latched shunt and strike) automatically when the entry area is disarmed. The door will re-lock upon Master or Perimeter Arming the area Yes When the area assigned in D# Entry Area # is disarmed, the door will be in the Unlocked state. When that area is armed, the door will return to the Locked state. Door state will not be affected by the armed state of the area. The Unlocked state cannot be overridden manually. Doors that are activated by Fire Unlock must be returned to normal using the Door Control function on the control center. D# Fire Unlock? Use this program item to activate the relay for the door strike and shunt the door zone automatically upon a Fire Alarm. This feature will override a Secure Door state, Locked Door state, Auto Door, and an Interlock faulted point. The relay will activate for all doors with this prompt programmed [YES] when a Fire Alarm occurs in any area. Relays that are activated by Fire Unlock can only be returned to normal through the Command Center using the Door Control function. Yes Relay will activate and shunt will be applied for the door contact automatically upon a Fire Alarm. Door will remain in its current mode upon a Fire Alarm. DANGER! This will unlock the door regardless of the armed state. D# Disarm On Open? Use this program item to determine whether the door needs to be physically opened prior to disarming the area upon a valid access request. The user initiating the access request must have access levels that allow disarming with ID. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

8 en Door Profile Access Control Interface Module Yes The area will disarm only after the door has been opened for a user with a valid disarm level. The area will disarm whether or not the door has been opened as soon as a user with a valid disarm level has presented a valid token/card. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Strike Profile en 9 3 Strike Profile This programming category is used to create a specific door profile on: Strike and shunt times. Extending strike and shunt times if a door is left open. Resetting the strike when the door opens. Programming the interlock point. Door # 1 Selections 1-8 Enter the door you are programming. D# Strike Time 10 1-240 seconds Enter the amount of time the relay output for the strike will activate to allow a user to open the door. The strike will activate upon a valid token, Request to Enter [RTE], Request to Exit [REX], and the Command Center [CYCLE DOOR?] function. Blank Strike Time is not programmed for this door. 1-240 The strike will activate for the amount of time programmed. D# Shunt Time 10 Blank, 1-240 Enter the amount of time that the door point will be shunted to allow a user to open the door without causing the point to go into Trouble, Alarm or a faulted condition. Blank TShunt Time is not programmed for this door. 1-240 The shunt will activate for the amount of time programmed. D# Buzz Time 2 Blank, 1-240 seconds Enter the amount of time that the buzzer output will activate to notify the user that the strike has been activated and the door is ready to open. The buzzer will stop as soon as the door is opened. A separate buzzer is required. Many readers have an internal buzzer that is not affected by Buzz Time. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

10 en Strike Profile Access Control Interface Module Blank Buzz Time is not programmed for this door. 1-240 The buzzer will sound for the amount of time programmed. D# Extend Time 10 Blank, 1-30 seconds Enter the amount of time that strike, buzz and shunt activation will be prolonged if a door is left open and the shunt time expires. At the end of the programmed extend time, the buzzer will continue to buzz until the door is closed. In addition, if programmed, the point assigned to the door will indicate a Trouble, Alarm or Fault at the command center. CLOSE DOOR # display on Command Center will not activate if no time (blank) is programmed. Regardless of how the door point is programmed, the system will generate a Trouble Door Left Open event while the system is disarmed and an Alarm Door Left Open event if the system is armed and the door is held open beyond Extend Time. Door Closed Restoral events are generated after the door is held open past Extend Time and the door has returned to normal. D# Deact On Open? This program item determines whether the strike will deactivate immediately upon physically opening the door. Yes Strike will deactivate when the door is opened after a valid access granted request. Strike will remain activated for the amount of the programmed strike time whether door is opened or closed. In order for this function to work a point needs to be assigned to the door. TO REDUCE FALSE ALARMS: We recommend that you maintain this programming item as defaulted [YES]. This will help prevent the door from bouncing open and causing a false alarm. D# RTEShunt Only? Use this program item to disable the strike, but still activate the programmed shunt time upon a Request to Enter an area. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Strike Profile en 11 Yes Programmed shunt time will activate so door can be manually opened. Request to Enter [RTE] automatically activates the programmed strike and shunt time. Use this parameter when a user can open a door manually without relying on a token/card to activate the strike (such as with a push bar ). When RTE Shunt Only is [Yes] Request To Enter events are not logged, reported, or printed. D# REXShunt Only? Use this program item to disable the strike, but still activate the programmed shunt time upon a Request to Exit an area. Yes Programmed shunt time will activate so door can be manually opened. Request to Exit [REX] automatically activates the programmed strike and shunt time. When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

12 en Event Profile Access Control Interface Module 4 Event Profile This programming category is used to determine if events are created for: Access Ganted and Access Denied. Door Requests. Door state changes due to manual (command center) or automatic scheduled or armed state changes (skeds/hold open on disarm, normal on armed) operation. Door # 1 Selections 1-8 Enter the door you are about to program. RTE events require Access Granted to be programmed [YES]. D# Access Granted? This program item determines if ACCESS GRANTED and DOOR REQUEST events are sent to the panel for processing memory, printing, and remote reporting. A successful access event can be initiated by a: Valid user ID. Valid door state changed at the command cener. Automatically scheduled or armed state changes that hold a door open. Request to enter/exit [RTE/REX]. Yes Access events from this door controller will be sent to the panel for processing. Access events from this door controller will not be sent to the panel for processing. D# Entry? This program item determines if Entry events are sent to the panel for processing memory, printing, and remote reporting. A Entry event may be caused by: Invalid or unknown user ID, interlock or secured door, or incorrect authority level. Request to enter/exit [RTE/REX] for door in interlock or secured door. Yes Access denied events from this door controller will be sent to the panel for processing. Access denied events from this door controller will not be sent to the panel for processing. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Event Profile en 13 D# Enter Request? This program item determines if Request to Enter [RTE] events are sent to the panel for processing memory, printing, and remote reporting. Yes A DOOR REQUEST TO ENTER event from this door controller is sent to the panel for processing. A DOOR REQUEST TO ENTER event from this door controller is not sent to the panel for processing. RTE events require D# Access Granted to be programmed [YES]. D# Exit Request? This program item determines if Request to Exit [REX] events are sent to the panel for processing memory, printing, and remote reporting. Yes DOOR REQUEST TO EXIT event from this door controller is sent to the panel for processing. A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for processing. REX events require D# Access Granted to be programmed [YES]. Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

14 en Event Profile Access Control Interface Module 4.1 tes F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Access Control Interface Module Program Record Sheets en 15 5 Program Record Sheets Contained in this section are the Program Record Sheets used to document the configuration at a customer site. Please feel free to de-attach this section for your records. Summary account information Subscriber name Date Address City / State / Zip Premises phone Installer name Door # Point # Point Text Location 1 2 3 4 5 6 7 8 Door # s 3 through 8 for D9412 Family only Control/Communicator Location Bosch Security Systems, Inc. Program Entry Guide F.01U.201.526 02 2011.10

16 en Program Record Sheets Access Control Interface Module 5.1 Profiles 5.1.1 Door Profiles Door 1 Door 2 Door Door 4 Door 5 Door 6 Door 7 Door 8 Entry Area # (blank, 1-8) --- --- --- --- --- --- --- --- CC# Scope (blank, 1-8) --- --- --- --- --- --- --- --- Door Point (blank, 1-247)* --- --- --- --- --- --- --- --- Interlock Point (blank, 1-247)* --- --- --- --- --- --- --- --- Auto Door? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Fire Unlock? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Disarm On Open? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ * Points 128 and 248 are reserved for an internal panel function. These are not valid selections. When using the D7412 Family, the valid point range is 1-75. Doors 3 through 8 are available for the D9412 Family only. 5.1.2 Strike Profiles Door 1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Strike Time (1-240 sec) 10 10 10 10 10 10 10 10 Shunt Time (blank, 1-240 sec) 10 10 10 10 10 10 10 10 Buzz Time (blank, 1-247 sec) 2 2 2 2 2 2 2 2 Extend Time (blank, 1-30) 10 10 10 10 10 10 10 10 Deactivate On Open? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ RTE Shunt Only? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ REX Shunt Only? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Doors 3 through 8 are available for the D9412 Family only. 5.1.3 Event Profiles Door 1 Door 2 Door Door 4 Door 5 Door 6 Door 7 Door 8 Access Granted? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Entry? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Enter Request? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Exit Request? Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Yes/ Doors 3 through 8 are available for the D9412 Family only. F.01U.201.526 02 2011.10 Program Entry Guide Bosch Security Systems, Inc.

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 United States www.boschsecurity.com Bosch Security Systems, Inc., 2011