HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series



Similar documents
Speed sensor MiniCoder GEL 247

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Cross-beam scanning system to detect slim objects. 100 mm in

MCR1900 Media Converter 19-Slot Chassis

SECTION 13. Multipliers. Outline of Multiplier Design Process:

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Description. Dimensions. Features. precision works better

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

BITMAIN. APW PSU Series User Guide

How To Read A Pipe From A Sensor

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

DCS Input/Output Relay Card Series

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Mitel DECT Base Stations

Color Mark Sensor with Red or Green LED E3S-VS

Agilent 4339B/4349B High Resistance Meters

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

OPERATING INSTRUCTIONS

Adjustment functions for both span and shift have been incorporated

Electro-pneumatic control valves

Duct Humidity Transmitter

3mm Photodiode,T-1 PD204-6C/L3

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

How To Use A Flowmeter

Specification of 5 Wire Analog Touch Panel

AXIS 291 1U Video Server Rack Installation Guide

Multifunction devices

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

PART 1 - INTRODUCTION...

New XUY roller sensors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

User Manual for CH-PFC76810

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Technical Data. Dimensions

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

AutoRanging Digital MultiMeter

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Digital inductive conductivity transmitter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Electronic Control Devices The European Product Catalogue 2007

Electronically Controlled Clutchless or Variable Drive Compressors

Quick Connect. quick - simple - efficient.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

TIG INVERTER INSTRUCTION MANUAL

Climate chamber with illumination

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Product Description Sheet RB15 200D Gantry Robot Item No

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Model: DC-A2IO Advanced HVAC Controller

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Inductive sensor NI10-M18-Y1X-H1141

W150: Miniature photoelectric switch series with completely integrated electronics

TMS TANK MANAGEMENT SYSTEM

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Cable Discharge Event

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MOUNTING AND OPERATING INSTRUCTIONS

RADIANT PLASMA 4700 Plasma Spark Generator

Liquid Leakage Sensor Amplifier

Talon and Talon SR User Manual

PowerGem Pro Uninterruptible Power Supply

Peltier Application Note

Directory chapter 04

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

HF series Hall effect joysticks

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Energy Management Energy Meter Type EM23 DIN

unit : mm With heat sink (see Pd Ta characteristics)

SMART SENSOR COLLECTION

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Modular I/O System Analog and Digital Interface Modules

E-PDD Duct Smoke Detector Installation Sheet

Phase Modular Finally the benefits of Modular ups are for all

Guideline Laser Series

ELECTROMAGNETIC DISC BRAKES

Transcription:

NEW Ultra-High Speed, Sensing Ionizer SJ-H Series High Power High Quality Suitable for high-speed static elimination in wide areas, including clean room environments HSeries

The highest static elimination capacity in the industry L O W - V O L T A G E 2 4 V W I R I N G Low-voltage 24V wiring eliminates the adverse effect of discharge on cabling and surrounding equipment, allowing the construction of a highly reliable system. High-speed static elimination and high-precision ion balance Pulse AC method The SJ Series has adopted the pulse AC method that applies alternating high voltage to the electrode probe, producing ions of both polarities. Compared to the conventional AC method, the amount of ions generated is higher and the oscillating frequency can be changed. Therefore, the pulse AC method can be used in all conditions, from high-speed moving applications to static elimination of a work area. AC method + Ion generation Movement direction Dual I.C.C. (Dual Ion Current Control) system enables optimum static elimination The dual I.C.C. system is further advanced from the conventionally proven I.C.C. system found in other KEYENCE models. The SJ Series bar-type static eliminators adopt a dual I.C.C. system that can change the applied voltage in addition to the variable pulse width, thus providing more flexible control of ion generation level per unit time. This system enables optimum static elimination relative to a change in the ambient environment (temperature, humidity, etc.) and the electrode probe condition. Dual I.C.C. method Extending positive ion generation duty cycle Newly developed - 0Hz or 60Hz Pulse AC method + Ion generation Ion generation There are periods when no positive (+) or negative (-) ions are generated, therefore the positive (+) and negative (-) ions are distributed separately and cannot eliminate static effectively. Movement direction Changing negative generation voltage ion - 1Hz to 68Hz Ion generation The positive (+) and negative (-) ions are uniform and provide ideal static elimination. (At 33 Hz) Normal operation When an object with negative charge approaches 2

SJ-H Series front view Laminar flow of ions Support air I N D I C A T O R S & O U T P U T S Safety functions, abnormal discharge detection output, electrostatic charge monitor, and ion level alarm are standard features. The I.R.G. (Insert Ring Ground) structure provides the world's-highest static elimination speed. Newly developed [ times faster than conventional models] The SJ Series bar-type adopts the I.R.G. structure that incorporates the GND plate essential for ion generation into the ionizer body. This GND plate is externally mounted on conventional models. The I.R.G. structure directs the flow of generated ions toward the target object, instead of toward the GND plate. This structure increases the quantity of ions applied to the target, providing static elimination speed five times faster than conventional models. Double Port Electrode Probe [Double Port Electrode Probe] Newly developed In addition to the sheath air guide structure that minimizes dust adhesion, the double port electrode probe cap is used to ensure high-speed static elimination while maintaining laminar flow. Conventional model SJ-H Models * Elective length indicates the static elimination range at 0 mm operating distance. Static elimination length (Effective length) GND plate I.R.G. structure GND plate Model 380 mm (360 mm) SJ-H036A mm ( mm) SJ-H060A 840 mm (840 mm) SJ-H084A 1080 mm (1080 mm) SJ-H108A 1320 mm (1320 mm) SJ-H132A 160 mm (160 mm) SJ-H16A 1800 mm (1800 mm) SJ-H180A 2040 mm (2040 mm) SJ-H204A 2280 mm (2280 mm) SJ-H228A 220 mm (220 mm) SJ-H22A 3000 mm (3000 mm) SJ-H300A 3

The best maintenance-saving performance in the industry The sheath air guide structure reduces maintenance downtime Newly developed [ times less maintenance than conventional models] The supplied air is conveyed through a three-stage port in the probe cap, fully contained within the air chamber. The air contained in the chamber passes through the channel around the probe to generate a laminar flow. The concave structure at the air outlet blocks external disturbance, resulting in an excellent protective effect. This structure can remarkably reduce adhesion of foreign objects on the electrode probe tip. This results in five times less maintenance than conventional models. Sheath air guide structure Cross-sectional view of the electrode probe cap Maintenance indicators The SJ Series bar-type static eliminator includes a selfdiagnosis function that monitors the ion generation level. With the bar LED indicators and alarm outputs, the ionizer alerts you of the need for maintenance. Normal ion level Easy electrode probe replacement Ion level is low. (Example: Ion level reduction) Since the electrode probe is attached with a PIN connector or cassette, users can easily replace the electrode probe. Air supply 3-way alarm output The SJ Series provides the self-diagnosis function that monitors three types of abnormalities. If an abnormality is detected, the LED indicators identify the error condition and an external output is activated. Centralized control of ionizers is enabled by monitoring the external output. Air purge function The clean air supply function blows air from the area surrounding the electrode probe. This function helps to prevent dust adhesion to the electrode. y Cleaning warning Monitors reduction in ion generation level due to dirt or wear of the electrode probe. y Condition warning Monitors a high charge level that cannot provide a sufficient static elimination effect. y Alarm warning Monitors abnormal discharge or damage to the ionizer. N2 (nitrogen) purging static elimination As a standard feature, N2 purge systems used in semiconductor and liquid crystal manufacturing processes are compatible with the SJ-H Series static eliminators. 4

A P P L I C A T I O N S Static elimination of slitters Prevent dust adhesion to ampoules after heat treatment Prevent foreign material adhesion between heat seal layers Static elimination in the coating process of bumpers Chip removal during cutting sashes Defect prevention in the offset printing process Static elimination of unwoven cloth Defect prevention of adhesive painting on cardboard Static elimination when attaching copper plates/films Prevention of adhesion in metal moulds Static elimination of building material boards Static elimination of films Static elimination during assembling car navigation systems Static elimination of ECU substrates on conveyor lines Static elimination in the air shower

S P E C I F I C A T I O N S Model SJ-H036A SJ-H060A SJ-H084A SJ-H108A SJ-H132A SJ-H16A SJ-H180A SJ-H204A SJ-H228A SJ-H22A SJ-H300A Ion generation method Corona discharge method Structure Shock-proof, resistance-coupled type Voltage application method/applied voltage Pulse AC method/±7000 V Ion balance control method Dual I.C.C. method Ion balance 1. ±30 V Operating distance 0 to 2000 mm Control input NPN open collector or non-voltage contact signal Control output NPN type photo-relay, 100 ma max. (40 V max.) Power supply voltage 24 VDC-36 V±10% Ratings Current consumption 00 ma (at 24 VDC)/30 ma (at 36 VDC) Overvoltage category I Pollution degree 2 Primary features Condition alarm, ion level alarm, alarm output Air purge connection port Rc 1/8 Air purge air supply pressure 0. MPa or less Materials Electrode probe Tungsten Body ABS resin/pc Environmental resistance Effective length 2. Total length (A) 3. Weight Ambient temperature 0 to +40 C Relative humidity 3 to 8%RH (No condensation) 360 mm 380 mm mm 840 mm 1080 mm 1320 mm 160 mm 1800 mm 2040 mm 2280 mm 220 mm 3000 mm Controller 10 g Static elimination bar 00 g 780 g 980 g 1200 g 1400 g 10 g 170 g 2000 g 0 g 2700 g 310 g 1. The value is measured under the following condition. Operating distance Operating ambient temperature Operating ambient humidity 300 mm (22 Hz) mm (10 Hz) 0 to +40 C 3 to 6%RH 100 mm (1 Hz) Under a 0.3 m/s downflow 2. The effective length is determined based on the static elimination range at a distance of 0 mm. 3. The total length includes the end units. C H A R A C T E R I S T I C S Static elimination range vs. static elimination time (33 Hz) Static elimination range vs. static elimination time (10 Hz) Static elimination range vs. static elimination time (1 Hz) 10 100 0 0 100 10 mm 40 300 10 10 300 40 mm 40 300 10 10 300 40 mm 300 0 300 4 sec sec 6 sec 100 10 mm 0.4 sec 0.6 sec 0.8 sec 1.0 sec 1.2 sec Using a 10 x 10 mm plate monitor (20 pf). Model: SJ-H108A, No downflow 900 mm 30 sec 0.4 sec 0.6 sec 0.8 sec 10 sec 1.0 sec 1.2 1 sec Using 10 x 10 mm plate monitor (20 pf). Model: SJ-H108A, under a 0.3 m/s (0.98 ft/s) downflow 900 1200 100 mm 30 sec 10 sec 20 sec Using 10 x 10 mm plate monitor (20 pf). Model: SJ-H108A, under a 0.3 m/s (0.98 ft/s) downflow Relationship between air pressure and air volume according to static elimination bar length (with air supply at both sides) Supplied air volume (Nl/min) 1200 1000 800 400 200 SJ-H036A SJ-H060A SJ-H084A SJ-H108A SJ-H132A SJ-H16A SJ-H180A SJ-H204A SJ-H228A SJ-H22A SJ-H300A Relationship between static elimination speed and operating distance according to air pressure Static elimination time (sec) 10 8 6 4 2 0MPa 0.002MPa 0.01MPa 0.2MPa 0.MPa Static elimination range vs. static elimination time (Maximum air supply) 40 300 10 10 300 40 mm 300 900 1200 4 sec 0. sec 6 sec 1 sec 10 sec 0 0.1 0.2 0.3 0.4 Air pressure (MPa) 0. 0 0 100 10 200 20 300 Operating distance (mm) 100 mm 30 sec 3 sec 20 sec 2 sec Using 10 x 10 mm plate monitor (20 pf). Model: SJ-H108A, No downflow Using 10 x 10 mm plate monitor (20 pf). Model: SJ-H108A, No downflow 6

Table of dimensions by model Unit: mm Model SJ-H036A SJ-H060A SJ-H084A SJ-H108A SJ-H132A SJ-H16A SJ-H180A SJ-H204A SJ-H228A SJ-H22A SJ-H300A A Total length 380 840 1080 1320 160 1800 2040 2280 220 3000 B Static elimination bar length 340 60 800 1040 1280 120 1760 2000 2240 2480 2960 C Mounting pitch 36 8 82 106 130 14 178 202 226 20 298 D Electrode pitch and length P60 x 3=180 P60 x 7=420 P60 x 11=660 P60 x 1=900 P60 x 19=1140 P60 x =1380 P60 x 27=1620 P60 x 31=1860 P60 x 3=2100 P60 x 39=40 P60 x 47=2820 D I M E N S I O N S Unit: mm When the end units are attached 10. One intermediate support bracket 10 must be used for a bar length of 1 m (67.7) 48. 9.2 B 21 A C The SJ-H036A does not have this modular port. D 2 39 22. 11 21 2. 12. 70 1. SJ-H036A only 12. 1. 90 mm for the SJ-H036A 2. SJ-H036A only Left side of the bar (Common to all models) 39. 22. (R24) 2. (R24) 1. 48 Right side of the bar (Common to all models longer than and including the SJ-H228A model) 39. Rc1/8 1. 22. 22 48 SJ-H036A (Controller) 71 9 130 120 2-ø 33 (28) 4 4 Rc1/8 Rc1/8 (14.) 48.2 (R24) 1. The SJ-H036A does not have this modular part. 2. SJ-H036A only 1. Not provided for the SJ-H204A or shorter models. (43) (3) End unit (OP-84301) Intermediate support bracket (OP-84300) End unit L 39. 22. 39. 3 10. 20 12. End unit R 20 12. 10. 39. 22. 3 39. 22. (Rear view) 28 2 x slot (Note 2) (Thickness: ) Note: Detail of slot 6 4 x slot (Note) 12. 12. 4 x slot (Note) Note: Detail of slot 6 Note 1: Detail of slot 2.6 Note 2: Detail of slot 1.4 34 4 4.4 11 11 4.4 4.4 4.4 2 x slot (Note 1) (Thickness: ) 7

When a rotating mounting bracket is attached Unit: mm (119) 29 18 61.3 48. 9.2 21 A B C The SJ-H036A does not have this modular port. Left side of the bar (Common to all models) 99. Total length (A) Mounting pitch (B) Mounting pitch (C) SJ-H036A 41 432 400 SJ-H060A 671 62 620 SJ-H084A 911 892 860 SJ-H108A 111 1132 1100 SJ-H132A 1391 1372 1340 SJ-H16A 1631 1612 180 SJ-H180A 1871 182 1820 SJ-H204A 2111 2092 2060 SJ-H228A 1 32 00 SJ-H22A 291 272 240 SJ-H300A 3071 302 3020 (79.) 27. (R24) 1. Right side of the bar (Common to all models longer than and including the SJ-H228A model) Rc1/8 1. 21 2. SJ-H036A only. (R24) 2. 4 4 Rc1/8 99. 27. 73. Rc1/8 30 70 1. 1. 90 mm for the SJ-H036A 2. SJ-H036A only 1. The SJ-H036A does not have this modular port. 2. SJ-H036A only. 1. Not provided for the SJ-H204A or shorter models. Rotating mounting bracket (side) OP-84297 Rotating mounting bracket (intermediate) OP-84298 4 68.6 27. 3 91 86 27. 64.7 Note: Detail of slot 16 30 (When rotated at 90 ) Note: Detail of slot 2 x slot (Note) (When rotated at 90 ).2 8 29 18 (40).4 78 62 (40) 27. 4 x slot (Note) 63. 4 40 O P T I O N S SJ-C2U/CU/C10U OP-42210/OP-42211/ OP-42212 SJ-C2H/CH/C10H OP-84299 OP-42218 OP-8444 OP-844 10-pin I/O cable (2 m, m, 10 m) 10-pin/10-pin cable (For OP-84296) (2 m, m, 10 m ) 10-pin/10-pin cable (for SJ-H036A) (2 m, m, 10 m ) Electrode tip cleaning kit for SJ-H Series Replacement filter for electrode cleaning kit (10 pieces) Electrode port cleaning kit 2 for SJ-H Series Replacement filter for electrode cleaning kit 2 (10 pieces) OP-84363 (Spare) OP-84293 OP-84296 OP-84300 (Spare) OP-84301 (Spare) OP-84297 OP-84298 Electrode probe replacement kit for SJ-H Series Tungsten electrode probe for SJ-HA (4 pieces) Junction relay box for SJ-H Series Intermediate support bracket for SJ-H Series End unit for SJ-H Series Rotating mounting bracket pair (right and left sides) Rotating mounting bracket (intermediate) C O N T A C T U S +32 1-28-1222 www.keyence.eu E-mail: info@keyence.eu SAFETY INFORMATION Please read the instruction manual carefully in order to safely operate any KEYENCE product. KEYENCE INTERNATIONAL (BELGIUM) NV/SA / KEYENCE MICROSCOPE EUROPE Head office Bedrijvenlaan, 2800 Mechelen, Belgium Tel: +32 1-28-1222 Fax: +32 1-20-16 Regional sales offices BELGIUM Tel: +32 1-28-1220 Fax: +32 1-20-16 AUSTRIA Tel: +43 22-36-3782-66-0 Fax: +43 22-36-3782-66-30 CZECH REPUBLIC Tel: +420 222-191-483 Fax: +420 222-191-0 HUNGARY Tel: +36 1-802-73-60 Fax: +36 1-802-73-61 NETHERLANDS Tel: +31 40-20-66-100 Fax: +31 40-20-66-111 POLAND Tel: +48 71-36861-60 Fax: +48 71-36861-62 ROMANIA Tel: +40 269-2-808 Fax: +40 269-2-808 SLOVAKIA Tel: +421 2-939-6461 Fax: +421 2-939-6200 KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 33-8, Japan PHONE: +81-6-6379-2211 The information in this publication is based on KEYENCE s internal research/evaluation at the time of release and is subject to change without notice. Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved. SJHA-KIB-C-E 1043-1 626013 Printed in Japan SLOVENIA Tel: +386 1-4701-666 Fax: +386 1-4701-699 SWITZERLAND Tel: +41 43-477-30 Fax: +41 43-477-40 KIB1-1033 * 6 2 6 0 1 3 *