Modul pro rozeznání otisku prstu FPM 611-0 Stand-alone režim Instalace Návod k obsluze. Produktinformation



Similar documents
System Manual 1+n technology Issue 2013

ROLLING STOCK CABLES

(51) Int Cl.: G06F 13/38 ( ) G06F 1/16 ( )

NUMERIC SIGN SP2-6XX / 180mm. Presentation

design guide nightlife flair

NUMERIC SIGN SP2-6XX / 100mm. Presentation

Direct AC Wiring Option Installation Guide

Backup Scanner Module

Capteur température et humidité pour HVAC

QUICK START BALANCE AUDIO INTERFACE QUICK START DÉMARRAGE RAPIDE KURZANLEITUNG

Personnalisez votre intérieur avec les revêtements imprimés ALYOS design

INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor

General Certificate of Education Advanced Level Examination June 2012

Note concernant votre accord de souscription au service «Trusted Certificate Service» (TCS)

Sun Enterprise Optional Power Sequencer Installation Guide

System Manual 1+n technology

Survey on Conference Services provided by the United Nations Office at Geneva

LOGOBOOK GUIDELINES & RULES

Inspection des engins de transport

"Internationalization vs. Localization: The Translation of Videogame Advertising"

Retail Products CHF CHF Reseller Pricelist. September 2006 CHF Enduser Price: CHF (incl.

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Compact I/O End Caps/Terminators

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

"Simultaneous Consecutive Interpreting: A New Technique Put to the Test"

(51) Int Cl.: G05F 3/26 ( ) G05F 3/24 ( )

Sun Management Center Change Manager Release Notes

ACS-30-EU-EMDR-10-MOD

EPREUVE D EXPRESSION ORALE. SAVOIR et SAVOIR-FAIRE

(51) Int Cl.: H04N 7/16 ( )

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

(51) Int Cl.: H04L 29/06 ( ) G06F 9/445 ( ) G06F 13/00 ( )

"Templating as a Strategy for Translating Official Documents from Spanish to English"

Regulatory Compliance Statement

Altiris Patch Management Solution for Windows 7.6 from Symantec Third-Party Legal Notices

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

How To Buy Gatedefender Performa And Performa For Free On A Discounted Price (For A Limited Time) For A Limited Period Of Time (For Free) On A Microsoft Gtv.Com) For $99.99 (

Detection of water leakage using laser images from 3D laser scanning data

FortiFone QuickStart Guide for FON-670i and FON-675i

AMBR AMATIS Border Router

Sun StorEdge A5000 Installation Guide

System Requirements Orion

Altiris Patch Management Solution for Windows 7.5 SP1 from Symantec Third-Party Legal Notices

Strathroy- Caradoc Police Services Board

openoffice impress 3 guide

Sun StorEdge RAID Manager Release Notes

Installation Instructions

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Operation Instructions PowerCool Series

Chassis Interface Module for 1746 Local I/O (Catalog Number 1747-PCIL)

TEPZZ_768 7_B_T EP B1 (19) (11) EP B1 (12) EUROPEAN PATENT SPECIFICATION. (51) Int Cl.: H04M 19/04 ( )

QUALITY. Pracovné odevy. Work clothes. Arbeitskleidung Les vêtements de travail. Munka ruhák

Wideband Optical Splitters FOS Series

E-Base Electrophoresis Device

NÜVO REVO mm 810 x 810 x ( ) No. Description

POB-JAVA Documentation

openoffice impress manual : The User's Guide

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

STRAHLER SPOTLIGHTS PROJECTEURS CONTROL 184_185

Montaj ve işletme kılavuzu Инструкция по монтажу и эксплуатации

Hours: The hours for the class are divided between practicum and in-class activities. The dates and hours are as follows:

Solaris Bandwidth Manager

Combi B Alarm box. Mounting instructions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

645 Vocal Element for KombiSIGN 71

Digital input modules

Audit de sécurité avec Backtrack 5

Power Thyristor TS3 (SP) 3ph. Installation Guide

(51) Int Cl.: H04M 3/50 ( )

(51) Int Cl.: H05K 1/02 ( )

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

Power Control. Solutions. Price List Liste de prix Smart Energy. Solutions. Solutions. énergétiques éclairées. cristalcontrols.

Les Broadcast Receivers...

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

Rousseau 10. User Guide

User guide. Stereo Bluetooth Headset SBH70

M2M Cellular Signal Amplifier

ALIMENTADORES POWER SUPPLIES ALIMENTATIONS ALIMENTAÇÃOS NETZGERÄT SERIE 903 SERIES

Immobiline DryStrip Reswelling Tray

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software

Calcul parallèle avec R

Solaris 10 Documentation README

Units PSENmag. PSEN 2.2p Unit features. Function description

Transponder reader CÉLIANE TECHNICAL GUIDE

Gateway Port Replicator User Guide

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Upgrade-Preisliste. Upgrade Price List

Germany Allemagne Deutschland. Report Q189. in the name of the German Group by Jochen EHLERS, Thorsten BAUSCH and Martin KÖHLER

Veritas Storage Foundation 5.0 Software for SPARC

(51) Int Cl.: G06F 11/20 ( )

Upgrading the Solaris PC NetLink Software

W 260: Standard photoelectric switch series for a broad range of applications

Read this document before using this product.

openoffice impress manual

Langages Orientés Objet Java

Installation Instructions

Transcription:

Produktinformation Finger Print Modul Stand-alone-Betrieb Bedienungsanleitung Fingerprint Module Stand-alone operation Operating instructions Module Finger-Print Mode autonome Notice d'utilisation Modulo Finger-Print Funzionamento stand-alone Installazione Istruzioni per l uso Finger-Print Module Stand-alone-werking Installatie Bedieningshandleiding Finger-Print Modulet Stand-alone -drift Betjeningsvejledning Finger-Print Modul Fristående drift Bruksanvisning Modul pro rozeznání otisku prstu Stand-alone režim Instalace Návod k obsluze

Löschmodus English Löschmodus Auslieferzustand herstellen Klappe auf der Rückseite des Moduls öffnen (siehe Bild 4 Betriebsmodus einstellen ). Den Drehschalter in die Stellung 0 oder 2...8 (Löschmodus) drehen. Alle eingelesenen Finge sind gelöscht. Benutzerfinger löschen Einzelne Benutzerfinger können nicht gelöscht werden! Mit dem Administratorfinger und mit den Masterfingern können die Benutzerfinger gelöscht werden. Die Masterfinger und der Administratorfinger bleiben erhalten. Zwischen den einzelnen Einlesevorgängen des Administratorfingers bzw. des Masterfingers nicht mehr als 5 s verstreichen lassen, sonst bricht der Löschvorgang ab. Wenn die LED grün wieder leuchtet, kann ggf. der Löschvorgang von vorne begonnen werden. Das Einlesen eines falschen Fingers bricht den Löschvorgang ebenfalls ab. Masterfinger/Administratorfinger 1-mal über den Sensor ziehen. Die LED grün blinkt, bis die LED rot ständig leuchtet (Einlesemodus). Masterfinger/Administratorfinger ein zweites Mal über den Sensor ziehen. Die LED grün blinkt, bis die LED rot ständig leuchtet (Einlesemodus). Masterfinger/Administratorfinger ein drittes Mal über den Sensor ziehen. Beide LEDs blinken gleichzeitig. Noch während beide LED s leuchten, Masterfinger/ Administratorfinger ein viertes Mal über den Sensor ziehen. Die LED grün leuchtet ständig. General The fingerprint module FPM 611-... in the Vario design is an access control system used in stand-alone operation. This module scans a fingerprint and uses it to actuate a function. Remark relating to the installation site The module can be integrated in all Vario housing models both outdoors and indoors. When used outdoors, we recommend keeping the module in a weather-protected area. Actuation of a function (e.g. door release) To actuate a function, for example a door release, a potential-free contact is available directly in the FPM 611-... (make time 3 secs.) Conductor material for installation In stand-alone operation, light current conductors type YR 0.8 mm core diameter can be used for the installation. Range The range between the transformer and FPM 611-... is limited to 130 m with 0.8 mm core diameter. Conductor routing In order to comply with the general safety regulations for telecommunication systems as per VDE 0100 and VDE 0800 and to avoid disturbing influences, ensure that heavy and light current conductors are routed separately, observing a distance of 10 cm. Safety remark/ pilfer safeguard In order to install an FPM 611-... with the necessary manipulation security, we recommend using pilfer safeguard controller DSC 602-0. In conjunction with pilfer safeguard accessory ZDS 601-0, the FPM 611-... can only be manipulated if considerable force is used. i Mounting 1 Terminal plan for standalone operation 2 (not illustrated) Insert the ribbon cable with combination plug. 3 (not illustrated) Insert the FPM 611-... into the mounting frame. Specifications 12 V AC supply from TR 602-... Current consumption max. 250 ma Operating contact 24 V/2 A Protection system IP 54 (when mounted) Ambient temperature -20 C to + 55 C ON time in stand-alone operation fixed at 3 seconds. 5

Operating instructions/ Commissioning The fingerprint module FPM 611-... in the Vario design is an access control system used in the standalone mode. In this system, a scanned fingerprint is used to actuate a function (such as a door release). Up to 20 users (scannable fingerprints) can be managed by the system. Which types of fingerprints i exist and what can they do? Any one finger can only be scanned in for one fingerprint type (administrator, master or user). Administrator fingerprint: Issues entitlement to scan in max. 5 master fingerprints. Only one administrator fingerprint can be scanned in. Master fingerprint: Issues entitlement to scan in max. 20 user fingerprints. User fingerprint: Entitled to actuate the relay integrated in the function (e.g. door release). Only user fingerprints can actuate this switching function. For your own information, it is advisable to note the fingerprints and the people they belong to who hold master and administrator entitlement (see below). Fingerprint table Administrator fingerprint Master fingerprint 1 Master fingerprint 2 Master fingerprint 3 etc.. 6 i 4 Operating mode In the FPM 611-... there are two different operating modes and a delete mode available. Administrator mode; One administrator fingerprint, up to 5 master fingerprints and up to 20 user fingerprints can be scanned in. Master mode; One master fingerprint and 20 user fingerprints can be scanned in. Delete mode; Deletes all fingerprints. 5 Module description a Red LED b Green LED c LED for lighting d Sensor LEDs (a) and (b) signal the status. Red and green LEDs flash alternately: After power has been connected or the device has been initialized. Red LED lights up: Module is ready for scan-in of an administrator, master or user fingerprint. Green LED lights up: (operating mode) Red and green LED off: fingerprint recognition being processed Green LED flashes for 3 secs, then lights continuously: Finger has been recognized. Red LED flashes for 2 secs, then green LED lights continuously: Finger has not been recognized, repeat scan-in process. Red and green LED flash simultaneously: Initialization on switching on / delete mode for all user fingerprints.! Important notes In individual cases, it can happen that a fingerprint cannot be scanned due to absence of biometric characteristics. This applies primarily to children and older people. In these cases it is possible that a fingerprint is not recognized. In this case, try using a different finger. Only one master fingerprint can enable the authorization to read in user fingerprints. If the rotary switch to set the operating mode is adjusted, all read-in fingers are deleted (asdelivered status)! 6 Draw the finger correctly over the sensor To ensure that the module is able to reliably recognize your fingerprint, draw it over the sensor to allow it to be scanned in. Ensure that you maintain as constant a speed, position and light contact pressure as possible. The read-in process must be started within 10 secs following activation, as otherwise the FPM 611-... returns to the operating status. Interruptions longer than 15 secs. automatically switch the system over to the operating mode (time out). Master mode Scan in master fingerprint The fingerprint module is in the master mode in its as-delivered status. Conditions: Device is initialized Red LED is alight (as-delivered status) the sensor. The green LED flashes for appr. 3 secs. after which the red LED lights up

the sensor again. The green LED flashes appr. 3 secs, then the red LED lights up. the sensor a third time. The green LED flashes for appr. 3 secs, after which the green LED lights up continuously. The master fingerprint has now been scanned in and is valid. It is now possible to scan in user fingerprints. LED flashes for 3 seconds, after which the green LED lights up. Repeat the scanning-in process. Scan in user fingerprints Condition: Green LED is alight (operating mode) Draw the master fingerprint once over the sensor. The red LED lights up. Draw the user fingerprint over the sensor. The green LED flashes for appr. 3 secs, then the red LED lights up. Draw the user fingerprint over the sensor again. The green LED flashes for appr. 3 secs, then the red LED lights up. Draw the user fingerprint a third time over the sensor. The green LED flashes for appr. 3 secs, then stays alight. LED flashes for appr. 3 secs. The green LED then lights up. Repeat the scanning in process. Check: Draw the user fingerprint once over the sensor. The green LED flashes and the relay picks up. Changing the operating mode In order to scan in the administrator fingerprint and several master fingerprints, you will first have to change the operating mode. The operating mode is set from the back of the module. 7 Module removal Use the Vario key to unlock the module (see also Siedle Vario product information) 8 Setting the operating mode Open the flap on the back of the module with the aid of a screwdriver. Set the required operating mode (0 to 9) at the rotary switch. Once the required operating mode has been set, close the flap and replace the module. Possible operating modes: 1 = Master mode 9 = Administrator mode 0, 2-8 = Delete mode Administrator mode Scan in the administrator fingerprint Condition: Administrator mode is set The red LED lights (as-delivered status) The fingerprint you scan in first in the administrator mode is the administrator fingerprint. over the sensor. The green LED flashes for appr. 3 secs, then the red LED lights up. over the sensor again.the green LED flashes for appr. 3 secs., after which the red LED lights up. a third time over the sensor. the green LED flashes for appr. 3 secs, after which the green LED lights up continuously. The administrator fingerprint has now been scanned in and is valid. Master fingerprints can now be scanned in. LED flashes for appr. 3 secs. The green LED then lights up. Repeat the scanning in process. Scan in master fingerprints over the sensor once. The red LED lights up (scan-in mode for master fingerprints). the sensor. The green LED flashes for appr. 3 secs, then the red LED lights up. the sensor again.the green LED flashes for appr. 3 secs., after which the red LED lights up. Draw the master fingerprint a third time over the sensor. The green LED flashes for appr. 3 secs, after which the green LED lights up continuously. The master fingerprint has now been scanned in and is valid. If you wish to scan in additional master fingerprints (max. 5), repeat the above described procedure. Or if you now wish to go on to scan in user fingerprints, jump to the section Scan in user fingerprints. LED flashes for appr. 3 secs. The green LED then lights up. Repeat the scanning in process. Check: Draw the user fingerprint once over the sensor. The green LED flashes and the relay picks up. 7

Delete mode Français Delete mode Restoring the as-delivered status Open the flap at the back of the module (see Fig. 4 Setting the operating mode ). Turn the rotary switch to the 0 or 2-8 position (delete mode). All fingers which have been scanned in are deleted. Delete user fingerprints It is not possible to delete individual user fingerprints! User fingerprints can be deleted with the administrator fingerprint and the master fingerprints. The master fingerprints and administrator fingerprint are retained. Between the individual scan-in processes of the administrator finger / master finger, you have a maximum 5 second window before the delete process is interrupted. If the LED lights up green again, it is possible to begin the delete process again from the beginning if required. Scanning in the wrong fingerprint will also cause the delete process to be interrupted. Draw the master fingerprint / administrator fingerprint once over the sensor. The green LED flashes until the red LED lights up continuously (scan-in mode). Draw the master fingerprint / administrator fingerprint over the sensor a second time. The green LED flashes until the red LED lights up continuously (scan-in mode). Draw the master fingerprint / administrator fingerprint over the sensor a third time. Both LEDs flash simultaneously. While the two LEDs are still alight, draw the master fingerprint / administrator fingerprint over the sensor a fourth time. The LED lights up continuously. Généralités Le module Finger-Print FPM 611-... en design Vario est un système de contrôle des accès, qui est utilisé en mode autonome (installation autonome). On utilise dans ce système une empreinte mémorisée pour déclencher une fonction. Remarque concernant le site d'installation Ce module peut être mis en place dans tous les boîtiers Vario, aussi bien à l'extérieur qu'à l'intérieur. Si vous installez le module à l'extérieur, nous vous conseillons de choisir une zone protégée contre les intempéries. Déclenchement d'une fonction (p. ex. gâche) Pour déclencher une fonction (p. ex. une gâche), on dispose d'un contact sans potentiel directement dans le FPM 611-... (temps de fermeture 3 sec.). Lignes pour l'installation On peut utiliser pour l'installation, en mode autonome, des lignes à courant faible YR d'un diamètre de fil de 0,8 mm. Portée Entre le transformateur et FPM 611-..., la portée est limitée à 130 mm, dans le cas d'un diamètre de fil de 0,8 mm. Cheminement des lignes Pour satisfaire aux dispositions générales en matière de sécurité concernant les installations de télécommunication, selon VDE 0100 et VDE 0800, et pour éviter les parasites, il faut veiller à faire cheminer séparément les lignes à courant fort et les lignes à courant faible. Une distance de 10 cm doit être respectée. Consigne de sécurité/ protection antivol Pour monter un FPM 611-... de façon à ce qu'il soit à l'abri des manipulations, nous conseillons d'utiliser un contrôleur de protection antivol DSC 602-0. En liaison avec l'accessoire antivol ZDS 601-0, le FPM 611-... ne peut être manipulé que par la force. i Montage 1 Schéma de branchement pour le mode autonome 2 (sans illustration) Introduire le câble plat avec le connecteur sur la borne combinée. 3 (sans illustration) Placer le FPM 611-... dans le châssis de montage. Caractéristiques techniques Alimentation 12 V CA fournie par TR 602-... Intensité absorbée max. 250 ma Contact de travail max. 24 V/ 2 A Indice de protection IP 54 (à l'état monté) Température ambiante -20 C à + 55 C Temps de commutation en mode autonome, 3 sec. fixe. 8

a c d b 1 5 4

6 7 8