TECHNICAL DATA. NOTES: For use with Trim Chart on page 27 b. (open fold-out)



Similar documents
TROU BLE SHOOTING VIKING ALARM VALVES

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Technical Data. Installation

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

PRESSURE REDUCING CONTROL VALVE

BERMAD Fire Protection

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

BERMAD Fire Protection

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Blowdown vessels Meeting the requirements of HSE PM60

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

NFPA31FuelOilPiping 1 Revised

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

Commercial Gas Water Heaters

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

TECHNICAL DATA. Dry 122a. November 12, 2013

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Model DE-3 Air Release Head

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

esfr pendent sprinkler vk510 (k25.2)

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Standard Hydraulic Piping Flushing Procedure

Fire Pump Plan Review March 2010

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Section 4 Page 2. Flow in Pipes

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

AIR LINE VALVES AND GAUGES

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Section 2 COYOTE Splice Case Series

I-768 FireLock NXT Dry Valve

Air Eliminators and Combination Air Eliminators Strainers

VAD. Variable Area Desuperheaters

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Installation & Operation

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

2- and 3-port valves with flanged connections, PN 10

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Metal Pressfitting Pipe Systems

MODEL BQ TECHNICAL BULLETIN BQ-TB BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS CAUTION

VOYAGER 570G. 744A Sprayer Control

FAIRBANKS NIJHUIS FIRE PUMPS.

VIKING HEAVY DUTY PUMPS SERIES 4195 STANDARD CONSTRUCTION

ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL

Direct steam injection humidifiers

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Goulds Water Technology

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Commercial Semi-Instantaneous Water Heaters

Fire Alarm System Monitoring - CAN/ULC-S561-03

! WARNING. Before using product, read and understand instructions.

VAD Variable Area Desuperheaters

BERMAD Waterworks. Surge Anticipating Control Valve. 700 Series. Model 735-M. Features and Benefits. Major Additional Features

1805 Series Relief Valves

Failure to follow these codes, regulations and recommendations could result in hazardous installation, bodily injury and/or death.

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

OREGON FIRE CODE Interpretations and Technical Advisories

300 Series PA Pump and Cooler Assemblies

Installation Manual DIAPHRAGM WELL TANK

ACCUMULATOR INSTALLATION

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Morrison Bros. Co. General Product Specifications

Installation Manual DIAPHRAGM WELL TANK

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

SECTION DIESEL-DRIVEN, FIRE PUMPS

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Sanitary and CIP Toroidal Sensor

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Direct-Operated Pressure & Temperature Regulating Valves

Operators manual Basic water heater

Transcription:

De cem ber 6, 1999 Trim 27 a MODEL J-1 ALARM CHECK VALVE VERTICAL TRIM Maximum 250 PSI WWP This Trim Chart is for use with the following Viking Trim Sets Valve Size Standard* Trim P/N Foam System** Trim P/N 3" 08633 08637 4" 08634 08638 6" 08635 08639 8" 08636 08640 * Standard Trim Sets for Model J-1 Alarm Check Valves in clude gal va nized nip ples and fit tings. (See Trim Chart Notes). ** Trim sets for Model J-1 Alarm Check Valves used on pre-mixed foam systems con sist of black steel nip ples and cast iron or ductile iron fit tings. (See Trim Chart Notes.) Or der Alarm Valve sep a rately. For de tailed trim chart, open to page 27 b. General Notes: NOTES: For use with Trim Chart on page 27 b. (open fold-out) Valve must be trimmed as shown. Any deviation from trim size or arrangement may af fect the proper operation of the valve. All pipe, 3/4" (20 mm) and smaller, shall be galvanized steel except when other materials are specified in the tech ni cal data for the system used. All trim components must be listed for up to 250 PSI (1 724 kpa) Water Working Pressure. When the Model J-1 Alarm Check Valve is used on pre-mixed foam sys tems, trim pip ing must be of black steel pipe with cast iron or mal - leable iron fittings unless other materials are spec i fied in the Tech ni cal data for the system used. Dimensions in parentheses are millimeter. Note 1: When using a water motor alarm, a strainer is required. Circuit closer vent trim may be re quired when an alarm pressure switch is used. (See tech ni cal data for the retard cham ber.) Note 2: This lo ca tion may be used for optional pressure re lief valve (not available from Viking). In stall 3/4" (20 mm) tee and listed pressure relief valve. Note 3: To supply an optional ex cess pressure pump (not available from Vi king and not a listed as sembly), replace ½" ell marked A with a tee. Re - place 3/4" ell marked B with a tee to connect outlet from excess pressure pump. Do not exceed listed water working pressure rating of system components. Perform hydrostatic tests in accordance with recognized Installation Standards. Note 4: Location for non-interruptible pressure switch. When waterflow through the alarm valve occurs, supply to this location cannot be shut off un til water flow through the alarm valve stops. Note 5: Component spec i fied is included in Vi king trim sets; do not substitute. Use of com po nents other than specified will void any list ings and ap - prov als and may af fect operation of the valve. Note 6: 300 PSI (7 620 kpa) water pressure gauges are provided with trim. 600 PSI (15 240 kpa) water pressure gauges are available. Order sepa - rately when needed*. Refer to current Vi king Price Book. * NFPA 13 re quires gauges to have a min i mum limit not less than twice the normal wa ter working pres sure at the point where the gauges are in stalled. When nor mal wa ter work ing pres sure ex ceeds 150 PSI (3 810 kpa), or der 600 PSI (15 240 kpa) wa ter pressure gauges sep a rately. Form No. F_102993 Replaces page 27 a-c, dated July 1, 1999. (Revised trim pipe lengths for 4 valve and changed part number for in-line check valve on drawing on page 27 b).

Trim 27 b De cem ber 6, 1999 MODEL J-1 ALARM CHECK VALVE VERTICAL TRIM Maximum 250 PSI WWP Available since 1997. Or der Alarm Valve sep a rately. Re fer to page 27 a for Gen eral Notes and Notes 1 through 6.

De cem ber 6, 1999 Trim 27 c

THIS PAGE INTENTIONALLY LEFT BLANK Replaces page 27 a-c, dated July 1, 1999. (Revised trim pipe lengths for 4 valve and changed part number for in-line check valve on drawing on page 27 b). Form No. F_102993

February 9, 2007 Wet 27a Model J-1 alarm check valve Vertical trim Order Alarm Valve separately. This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Brass 3 (DN80) 08633 11428 4 (DN100) 08634 11429 6 (DN150) 08635 11430 8 (DN200) 08636 11431 General Notes: Valve must be trimmed as shown. Any deviation from trim size or arrangement may affect the proper operation of the valve. NOTES: For use with Trim Chart on page 27 b. All pipe, 3/4 (20 mm) and smaller, shall be galvanized steel except when other materials are specified in the technical data for the system used. All trim components must be listed for up to 250 PSI (17.2 bar) Water Working Pressure. Dimensions in parentheses are millimeter. Viking uses ASME fitting designations. Tee s shall be called out in the following order: 1 - largest outlet on run; 2 - Smaller outlet on run; 3 - Branch size. Note 1: When using a water motor alarm, a strainer is required. Circuit closer vent trim may be required when an alarm pressure switch is used. (See technical data for the retard chamber.) Note 2: This location may be used for optional pressure relief valve (not available from Viking). Install 3/4 (20 mm) tee and listed pressure relief valve. Note 3: To supply an optional excess pressure pump (not available from Viking and not a listed assembly), replace ½ ell marked A with a tee. Replace 3/4 ell marked B with a tee to connect outlet from excess pressure pump. Do not exceed listed water working pressure rating of system components. Perform hydrostatic tests in accordance with recognized Installation Standards. Note 4: Location for non-interruptible pressure switch. When waterflow through the alarm valve occurs, supply to this location cannot be shut off until water flow through the alarm valve stops. Note 5: Component specified is included in Viking trim sets; do not substitute. Use of components other than specified will void any listings and approvals and may affect operation of the valve. Note 6: 300 PSI (20.7 bar) water pressure gauges are provided with trim. 600 PSI (41.4 bar) water pressure gauges are available. Order separately when needed*. Refer to current Viking Price Book. * NFPA 13 requires gauges to have a minimum limit not less than twice the normal water working pressure at the point where the gauges are installed. When normal water working pressure exceeds 150 PSI (10.3 bar), order 600 PSI (41.4 bar) water pressure gauges separately. Form No. F_102993 Revised page replaces page 27 a-c dated September 21, 2006 (Added Brass Trim Part Numbers)

Wet 27b February 9, 2007 Model J-1 alarm check valve Vertical trim Available since 1997 Order Alarm Valve separately. Refer to page 28a for Notes

February 9, 2007 Wet 27c Model J-1 alarm check valve Vertical trim

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_102993 Revised page replaces page 27 a-c dated September 21, 2006 (Added Brass Trim Part Numbers)