for more efficiency. Differential Temperature Controller for Solar Thermal Plants for drinking water heating and heating support



Similar documents
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Heating Controller. Building Technologies HVAC Products

Adjustable room thermostat for heating only or cooling only systems

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

HCE80/HCC80/HCE80R/HCC80R

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HERZ-Thermal Actuators

OZW30. Central Unit SYNERGYR

Smile. The All-In-One Heating Controller

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Electronic Control Devices The European Product Catalogue 2007

TMS TANK MANAGEMENT SYSTEM

FX07 Field Controller

ACCESSORIES VISUALISATION

Quick Connect. quick - simple - efficient.

Flush-mounted room thermostats

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

RRV934. Multi-controller. Synco living

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

BUSINESS SYSTEMS MONITORING

FIREDEX Conventional Fire Panels

Material test chamber with mechanical convection

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Counter for Energy. We make energy measurable and secure your future.

Technical Information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

The UPS for the highest security in industry and data centres

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

IntesisBox KNX Modbus RTU master

User and installation manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Inwall Room Temperature Unit

Products and solutions for pumping, irrigation and piping

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

Software and Display instruments

Electronic Control Devices The European Product Catalogue 2007

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Remote control station WCM-FS 2.0 and solar controller WCM-SOL 1.0 home /

MOUNTING AND OPERATING INSTRUCTIONS

TRADE PRODUCTS Electronic systems for recreational vehicles Supplying controlling indicating

SYSTEM MONITORING Locally and remotely

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Incubator with mechanical convection

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

IntesisBox KNX Modbus TCP master

Climate chamber with illumination

Energy Communication Unit (ECU)

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Energy Communication Unit (ECU)

Contents. Introduction

T5000 T000 LCD Digital Fan Coil Thermostat

Controller board and power supply for vivimat III systems

UniPi technical documentation REV 1.1

Product Specification instalert Rapid Messenger Variable Message Sign

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Remote Monitoring and REC 501 Control Unit Product Guide

instabus KNX / EIB System System E F G H

KACO-monitoring. watchdog prolog insight sunwatch. Easy to install. Inverter integrated monitoring available

Inwall 4 Input / 4 Output Module

FX07 Field Controller

Push button 3gang standard flush-mounted xx

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Complete SCADA solution for Remote Monitoring and Control

15 Series - Electronic step relay and dimmer. Features SERIE

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Application/Connection Examples

Model: DC-A2IO Advanced HVAC Controller

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Split Controller. User Manual SM-SS-F 2009/01/04

How To Control A Korean Korean Power Plant

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Controlers. Controler

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

RAINCONTROL LCD Special

Conventional Fire Detection and Extinguishant Control System Specification

Installation Instructions. Thermo Call TC3

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Light scene push button 8gang comfort flush-mounted xx

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Hand-held thermometer Model CTH7000

RVS RVS AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Heat pump controller User manual. Siemens Switzerland Ltd HVAC Products

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Charge Controller CC611/CC612 Preliminary datasheet

F453. TiF453. User guide 10/11-01 PC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Transcription:

for more efficiency. Differential emperature ontroller for Solar hermal Plants for drinking water heating and heating support

2

0.9 End You have completed commissioning! Next 1.1 Evaluation Measured values Service hours Heat quantities Error list

6 smart Sol nano - measurements

7

smart Sol nano - equipment overview Solar controller - equipment levels Basic dvance Special Hardware Number inputs for temperature sensors P1000 3 3 3 thereof switchable (analog outputs 0...10V or PWM outputs or temperature inputs) - - - thereof usable as input for pulse encoder/impeller - - - thereof usable as input for global radiation sensor - - - Number inputs (male connectors) for analog vortex flow sensors - - - Number triac outputs, max. 1, for pumps and valves 1 1 1 Number relay outputs - change-over contact, pot.-free, max. 1 - for pumps, valves, boiler - - - Number high current relay outputs - make contact, pot.-free, max. 15 - for immersion heater, - - 1 boiler Number relays outputs - make contact, 230V output, not pot.-free, max. 1 - for boiler - 1 - Number fixed analog outputs 0 10V or PWM outputs for high-efficiency pumps 1 1 1 dditional supply terminals, 2 x 85V-265V for valves, 5V and 24V for sensors - - - SD card slot for data logging - - - USB port for access to SD card or P - - - coustic alarm in case of error messages - - - Power reserve for real-time clock (min. 8 h) Energy-saving switch power supply with a wide-range input, 85 265V, 50/60Hz - - - ransformer power supply, 230 V +/-10%, 50Hz Full graphic F colour display with backlight, dimmable - - - Full graphic FSN monochrome display with backlight System Multi-piece plastic housing Operation via rotary encoder and ES button Micro fuse incl. spare fuse, type 5x20mm, time-lag 2 2 2 Laser engraved connection diagram on the rear side of the terminal cover Wall mounting, installation in pump group or tank Protection class IP20 mbient temperature 0 40 ctive display area, width x height in mm 45x23 45x23 45x23 Maximum number national languages 10 10 10 Maximum number collector arrays 1 1 1 Maximum number tanks 1 1 1 Number hydraulic systems currently 1 3 3 Installation wizard Service wizard Solar heating support Operation and efficiency functions Differential temperature control (Delta--control) Fixed temperature control (Fixed--control) Solar controller - equipment levels Basic dvance Special Disable the tank recharge - - - Efficient tank charge - - - Priority charging - - - Low-flow-function for low-flow-plants - - - ube collector function hermostat function - Maximum number of freely selectable control functions - 1 1 Speed control and speed limitation of the pumps ollector defrosting - - - Holiday function - - - utomatic summer/winter time changeover - - - ollector minimum temperature Overtravel time for outputs Quick charging - - - Signal processing global radiation sensor - - - nti-legionella function in conjunction with back-up heating - Back-up heating via different heat sources - Direct back-up heating via electric immersion heater - - Heating return increase - - - harge zone control - - - Bypass in the solar circuit - - - Protective functions ollector emergency OFF ollector cooling ntifreeze ank maximum temperature limitation ank temperature limit cut-out nti-blocking protection Soft charge - - - ank cooling Monitoring and Service functions Sensor monitoring Monitoring the output parameters Plausibility checks Sensor balancing Display free tank sensor top - - - Service hour counter for outputs Data logging on SD card - - - Indication of measured values on the display Error list Manual Mode 8

Solar controller - equipment levels Basic dvance Special Reset of complete or parameter related factory settings Solar yield measurement via pump activation with data display Solar yield measurement via vortex and/or impeller with data display - - - Graphical representation of the solar yield on the display (from SD card or RM) - - - Number of heat meters for solar yield measurement 1 1 1 Display of O 2 -savings - - - Optional accessory and customized adaptions on request ssembly/operating instructions on D, safety instructions as a leaflet ssembly/operating instructions incl. safety instructions as a booklet ollector sensor P1000, grey Silicon, operation temperature range -40 +180, length 2.500mm, with ferrules ank sensor P1000, black PV, operation temperature range -5 +90, length 2.500mm, with ferrules Power cable, black 230V, 3poles, H05VV-F 3G0,75mm, length 1.500mm, with ferrules SD card, 2GB - - - Global radiation sensor - - - Vortex flow sensors, Grundfos types VFS - - - Resistors for disable tank recharge or sensor switching, - - - boiler sensor P100 = 130 Ω / P500 = 620 Ω / P1000 = 1,3 kω Module for integration of a water softening system, type Q solar - BW, Schriesheim - - - smart Box for remote access via internet and intranet: graphical visualization of the log-data, parameterization, software update, online operation - - - Local P software "smart Sol analyzer" for direct connection: graphical visualization of the logdata, parameterization, software update, online operation - - - OEM personalization 9

smart Sol Differential temperature controller for middle range solar thermal plants for drinking water heating and heating support ontrol of middle range solar thermal plants with up to 2 collector arrays or 3 tanks USOMER BENEFI 15 % higher performance of the plant by forecast of sun radiation (saving primary energy) efficient tank charge (saving pump current) Full graphic colour display for clear and logical visualization Innovative operation concept for easy handling Smart and time-saving wiring concept Installation wizard for safe commissioning Service wizard for targeted and quick customer service omprehensive operation, protective as well as monitoring and service functions Data logging for analysis and systematic plant optimization ttractive, elegant and puristic design Various equipment levels for different applications 10

HYDRULI SYSEMS Full graphic colour display S S Standard omfort ccess op S OPERION ND VISULIZION Full graphic F colour display with backlight Rotary encoder with Push, ES button Different operation levels for OEM, heating installer and end user Self-explanatory menu and user guidance ombination of plain text displays and symbols Different national languages S S S S S S S 0.9 End You have completed commissioning! Next 04. 07. 2012 09:15 WIRING Easily removable terminal cover for access to the terminal compartment Laser engraved connection diagram on the rear side of the terminal cover Generously dimensioned terminal compartment Variable wiring and connection possibilities Proven spring-type terminals onvenient, intersection-free wiring Strain relief device INSLLION ND SERVIE WIZRD Developed in cooperation with Regensburg University and heating trade Solar thermal plant is ready to operate with just a few settings fter free assignment of inputs and outputs the matching plant system will be suggested Optical and/or acustical indications of malfunctions and errors Possibility of a preliminary diagnosis by the enduser in case of error messages Recommendations for the installer to eliminate malfunction or to perform maintenance work S with the option water softening system Q solar 1.1.4 Heat quantities 800 600 400 200 0 365d [kwh] 04. 07. 2012 10:22 PLN VISULIZION Indication of measured values for inputs and outputs Service hour counter for outputs Display O 2 -savings Error list Solar yield measurement with data display and graphical representation Remote access plus software packages for plant monitoring and optimization D INERFES Data interfaces such as SD card for data logging and USB for P connection 11

12 smart Sol - measurements

13

smart Sol - equipment overview Solar controller - equipment levels Standard omfort ccess op Hardware Number inputs for temperature sensors P1000 4 4 4 6 thereof switchable (analog outputs 0...10V or PWM outputs or temperature inputs) - 1 1 1 thereof usable as input for pulse encoder/impeller 2 2 2 2 thereof usable as input for global radiation sensor - - - - Number inputs (male connectors) for analog vortex flow sensors - - 1 1 Number triac outputs, max. 1, for pumps and valves 2 2 2 2 Number relay outputs - change-over contact, pot.-free, max. 1 - for pumps, valves, - 1 1 1 boiler Number high current relay outputs - make contact, pot.-free, max. 15 - for immersion - - - - heater, boiler Number relays outputs - make contact, 230V output, not pot.-free, max. 1 - for boiler - - - - Number fixed analog outputs 0 10V or PWM outputs for high-efficiency pumps - - - 2 dditional supply terminals, 2 x 85V-265V for valves, 5V and 24V for sensors - - - - SD card slot for data logging - - USB port for access to SD card or P - - coustic alarm in case of error messages - Power reserve for real-time clock (min. 8 h) Energy-saving switch power supply with a wide-range input, 85 265V, 50/60Hz - - - - ransformer power supply, 230 V +/-10%, 50Hz Full graphic F colour display with backlight, dimmable Full graphic FSN monochrome display with backlight - - - - System Multi-piece plastic housing Operation via rotary encoder and ES button Micro fuse incl. spare fuse, type 5x20mm, time-lag 2 2 2 2 Laser engraved connection diagram on the rear side of the terminal cover Wall mounting, installation in pump group or tank Protection class IP20 mbient temperature 0 40 ctive display area, width x height in mm 47x35 47x35 47x35 47x35 Maximum number national languages 15 15 15 15 Maximum number collector arrays 2 2 2 2 Maximum number tanks 2 2 2 3 Number hydraulic systems currently 9 20 20 24 Installation wizard Service wizard Solar heating support Operation and efficiency functions Differential temperature control (Delta--control) Fixed temperature control (Fixed--control) Solar controller - equipment levels Standard omfort ccess op Disable the tank recharge - Efficient tank charge Priority charging Low-flow-function for low-flow-plants ube collector function hermostat function Maximum number of freely selectable control functions 1 2 2 2 Speed control and speed limitation of the pumps ollector defrosting Holiday function utomatic summer/winter time changeover ollector minimum temperature Overtravel time for outputs Quick charging Signal processing global radiation sensor - - - - nti-legionella function in conjunction with back-up heating - Back-up heating via different heat sources - Direct back-up heating via electric immersion heater - - - - Heating return increase - harge zone control Bypass in the solar circuit Protective functions ollector emergency OFF ollector cooling ntifreeze ank maximum temperature limitation ank temperature limit cut-out nti-blocking protection Soft charge ank cooling Monitoring and Service functions Sensor monitoring Monitoring the output parameters Plausibility checks Sensor balancing Display free tank sensor top Service hour counter for outputs Data logging on SD card - - Indication of measured values on the display Error list Manual Mode 14

Solar controller - equipment levels Standard omfort ccess op Reset of complete or parameter related factory settings Solar yield measurement via pump activation with data display Solar yield measurement via vortex and/or impeller with data display Graphical representation of the solar yield on the display (from SD card or RM) Number of heat meters for solar yield measurement 2 2 2 2 Display of O 2 -savings Optional accessory and customized adaptions on request ssembly/operating instructions on D, safety instructions as a leaflet ssembly/operating instructions incl. safety instructions as a booklet ollector sensor P1000, grey Silicon, operation temperature range -40 +180, length 2.500mm, with ferrules ank sensor P1000, black PV, operation temperature range -5 +90, length 2.500mm, with ferrules Power cable, black 230V, 3poles, H05VV-F 3G0,75mm, length 1.500mm, with ferrules SD card, 2GB - - Global radiation sensor - - - - Vortex flow sensors, Grundfos types VFS - - Resistors for disable tank recharge or sensor switching, boiler sensor P100 = 130 Ω / P500 = 620 Ω / P1000 = 1,3 kω - Module for integration of a water softening system, type Q solar - BW, Schriesheim - smart Box for remote access via internet and intranet: graphical visualization of the log-data, parameterization, software update, online operation - - Local P software "smart Sol analyzer" for direct connection: graphical visualization of the log-data, parameterization, software update, online operation - - OEM personalization 15

1.1.4 Heat quantities 800 600 400 200 0 365d [kwh] 04. 07. 2012 10:22

18 smart Sol plus - measurements

19

smart Sol plus - equipment overview Solar controller - equipment levels Excellence Premium Hardware Number inputs for temperature sensors P1000 8 10 thereof switchable (analog outputs 0...10V or PWM outputs or temperature inputs) 2 4 thereof usable as input for pulse encoder/impeller 3 4 thereof usable as input for global radiation sensor 1 1 Number inputs (male connectors) for analog vortex flow sensors 1 2 Number triac outputs, max. 1, for pumps and valves 4 4 Number relay outputs - change-over contact, pot.-free, max. 1 - for pumps, valves, boiler 1 1 Number high current relay outputs - make contact, pot.-free, max. 15 - for immersion heater, boiler - - Number relays outputs - make contact, 230V output, not pot.-free, max. 1 - for boiler - - Number fixed analog outputs 0 10V or PWM outputs for high-efficiency pumps 2 - dditional supply terminals, 2 x 85V-265V for valves, 5V and 24V for sensors SD card slot for data logging USB port for access to SD card or P coustic alarm in case of error messages Power reserve for real-time clock (min. 8 h) Energy-saving switch power supply with a wide-range input, 85 265V, 50/60Hz ransformer power supply, 230 V +/-10%, 50Hz - - Full graphic F colour display with backlight, dimmable Full graphic FSN monochrome display with backlight - - System Multi-piece plastic housing Operation via rotary encoder and ES button Micro fuse incl. spare fuse, type 5x20mm, time-lag 4 4 Laser engraved connection diagram on the rear side of the terminal cover Wall mounting, installation in pump group or tank Protection class IP20 mbient temperature 0 40 ctive display area, width x height in mm 70x53 70x53 Maximum number national languages 15 15 Maximum number collector arrays 2 2 Maximum number tanks 4 4 Number hydraulic systems currently 30 30 Installation wizard Service wizard Solar heating support Operation and efficiency functions Differential temperature control (Delta--control) Fixed temperature control (Fixed--control) Disable the tank recharge Solar controller - equipment levels Excellence Premium Efficient tank charge Priority charging Low-flow-function for low-flow-plants ube collector function hermostat function Maximum number of freely selectable control functions 4 4 Speed control and speed limitation of the pumps ollector defrosting Holiday function utomatic summer/winter time changeover ollector minimum temperature Overtravel time for outputs Quick charging Signal processing global radiation sensor nti-legionella function in conjunction with back-up heating Back-up heating via different heat sources Direct back-up heating via electric immersion heater - - Heating return increase harge zone control Bypass in the solar circuit Protective functions ollector emergency OFF ollector cooling ntifreeze ank maximum temperature limitation ank temperature limit cut-out nti-blocking protection Soft charge ank cooling Monitoring and Service functions Sensor monitoring Monitoring the output parameters Plausibility checks Sensor balancing Display free tank sensor top Service hour counter for outputs Data logging on SD card Indication of measured values on the display Error list Manual Mode Reset of complete or parameter related factory settings 20

Solar controller - equipment levels Excellence Premium Solar yield measurement via pump activation with data display Solar yield measurement via vortex and/or impeller with data display Graphical representation of the solar yield on the display (from SD card or RM) Number of heat meters for solar yield measurement 4 4 Display of O 2 -savings Optional accessory and customized adaptions on request ssembly/operating instructions on D, safety instructions as a leaflet ssembly/operating instructions incl. safety instructions as a booklet ollector sensor P1000, grey Silicon, operation temperature range -40 +180, length 2.500mm, with ferrules ank sensor P1000, black PV, operation temperature range -5 +90, length 2.500mm, with ferrules Power cable, black 230V, 3poles, H05VV-F 3G0,75mm, length 1.500mm, with ferrules SD card, 2GB Global radiation sensor Vortex flow sensors, Grundfos types VFS Resistors for disable tank recharge or sensor switching, boiler sensor P100 = 130 Ω / P500 = 620 Ω / P1000 = 1,3 kω Module for integration of a water softening system, type Q solar - BW, Schriesheim smart Box for remote access via internet and intranet: graphical visualization of the log-data, parameterization, software update, online operation Local P software "smart Sol analyzer" for direct connection: graphical visualization of the log-data, parameterization, software update, online operation OEM personalization 21

smart Box smart Box omfortable remote access to smart Sol and smart Sol plus USOMER BENEFI No travel costs because of remote maintenance Professional plant monitoring and plant optimization No additional costs for apps FUNIONS Display of the current hydraulic plant system Evaluation and graphical visualization of the log data (solar yields, O 2 savings, temperatures, volume flows, behaviour of actuators) Quick and comfortable parameterization Online-operation of the controller Remote-controlled update of the smart Sol control software and the smart Box function software ll functions on the smart Box are also available as local P software smart Sol analyzer, therefore direct USB connection of the terminal device, e.g. notebook with the control 22

FEURES Remote access to smart Sol ESS and OP and smart Sol plus by smart Box via internet and intranet ccess both with LN and WLN ccess with different terminal devices, e.g. Ps, ablet Ps, smart phones, netbooks Use of terminal devices is independent from its operating system One smart Box can address 1 control Function software and operating system preinstalled on smart Box Integrated online help USB USB P echnical Data P Mains voltage 100 240V, 50/60Hz Ethernet / WLN Working memory 1 GB DDR3 Storage Network min. 8 GB SD Ethernet 10/100/1000 Mbps WiFi 802.11 n/g/b (300 Mbps) Ethernet / WLN Relevant ports 6 x USB 2.0 1 x VG Smart Phone Power consumption typical 16W Dimensions, width x height x depth 188 x 188 x 44 mm onditions smart Sol und smart Sol plus with USB port, SD card slot and SD card incl. data Router, configured for operation of smart Box Scope of delivery smart Box, preinstalled with operating system (Ubuntu-Linux) and function software Different national languages available adapter Stand Wall bracket Quick Start Guide on D and online DSL Router Internet P 23

www.emz-hanauer.com emz-hanauer GmbH & o. KGa Siemensstraße 1 D-92507 Nabburg info@emz-hanauer.com Version XX XX.XX.XXXX