1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide



Similar documents
1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Transformer Bushings for GIS

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

3/2-way Solenoid Valve, direct-acting, NC or NO

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

OLI. Oil level indicator

Vario-Series Accessories

CABLE ACCESSORIES kv

EDITION 2012 CABLE SYSTEMS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

a Nexans company Catalogue 2014

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

How To Build A Low Voltage Capacitor Lvcp

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

V47 Series Temperature Actuated Modulating Water Valves

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Type K current limiting fuse canister Technical information and installation guide

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Fault location on power cables. Fault location on power cables

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Transformer oil cooler ALFA A02

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

CRN A-F-G-E-HQQE 3x400D 50 HZ

System 8. ü ( System 8

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Cable Plug acc. to DIN EN , Form A

DS 600. A contact free flux gate based current measurement sensor 600A rms

Catalog May Cable Accessories < 1 kv

An Overview of Lapp Insulator High Voltage Bushing Design

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

CELO5. User & Installation Manual.

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Gulf Cable & Electrical Ind. Co.

08. SEK IDC CONNECTORS

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Precision Leaded Resistors

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

Subminiature Load Cell Model 8417

CAUTION. 4. Cable Connections DANGER WARNING CAUTION. 3. Bushing Components

Toroidal Conductivity Sensor

ECOCIAT. Domestic hot water heat recovery unit

I BEAM TRACK INSTALLATION

UGVCL/SP/591/11KV HT AB CABLE

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Gas insulated wall bushing, type GGFL

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Directory chapter 04

Explosion-Proof Electric Unit Heaters

James M. Pleasants Company

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

TECHNICAL INFORMATION

HERZ-Thermal Actuators

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Machine devices, jig devices

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Pneumatic actuators The Original! Technics of the top class.

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

SECTION DRY-TYPE TRANSFORMERS

A Study of a MV Cable Joint

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

Lightning Arresters P KVA P KVA. Description & Installation

Installation Manual. BYD Wall-mounted AC Charging Box

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

RUBBER SLEEVE KNIFE GATE VALVE

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Explosion proof enclosures

Operating Instructions Drill rig DRU160

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Waterproof Connectors for Outdoor Use

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

AMPSEAL* Automotive Plug Connector and Header Assembly

Medium-voltage transformers

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

3/2- and 2/2-way cartridge valve type BVE

Transcription:

1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide

Original instruction The information provided in this document is intended to be general and does not cover all possible applications. Any specific application not covered should be referred directly to ABB, or its authorized representative. ABB makes no warranty or representation and assumes no liability for the accuracy of the information in this document or for the use of such information. All information in this document is subject to change without notice. This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.

Content Design... 4 GOE features... 4 GOE(2) features... 4 Features and benefits... 5 Shed profile... 6 GOE... 6 GOE(2)... 6 Coon specifications... 6 Testing... 7 Test tap... 7 Test tap adapter... 7 Oil sampling valve... 7 Dimensions... 8 GOE 250-210 to GOE 950-650... 8 GOE 1050-750 to GOE 1800-1360... 10 GOE 2550... 12 GOE 2600... 13 GOE(2)... 14 Current capacity... 16 Short-time current... 16 Overload capacity of bushings... 16 Connection details... 17 Draw rod system... 17 Draw lead system... 19 GOE... 19 GOE(2)... 19 Outer terminal... 21 End-shields... 22 Ordering particulars... 24 Packing... 25 Additional GOE and GOE(2) bushings available on request... 26

Design The GOE bushing is available in two designs: GOE and GOE(2). The bushing is built up around a centre tube on which the condenser core is wound. For bushings up to 550 kv paper of full width is employed. Bushings for higher voltages are wound from paper strips in a manner similar to that used for cables. The foils are located so that the best possible combination of external flashover and internal puncture strength is achieved. The upper insulator, which is made in one piece without gaskets, the lower insulator and the mounting flange are held between the end plates by the centre tube and sealing is accomplished by oil-resistant rubber gaskets in grooves. For GOE 250 to 900 the top housing is equipped with two oil level gauges of prism type. For GOE 1050 and larger, the top housing is equipped with a magnetic oil level indicator. The mounting flange is an aluminium alloy casting. The gasket surface is machined flat. On the flange there is a test tap. This tap is automatically earthed by a protective cap when the tap is not connected to external test or measuring circuits. The mounting flange and the top housing are shot blasted to obtain a thoroughly smooth surface finish. The mounting flange can be equipped with extensions on the oil side, providing space for current transformers. The rated current is defined according to IEC 60137. It is valid only when the centre tube is used as conductor. For draw lead applications the permissible current will be lower. Please refer to the applicable section. Bushings GOE 450 and larger require a shield at the oil end. The purpose of this shield is to avoid excessive electrical stresses in the oil at the lower end plate and at the connection between the insulated lead from the transformer winding and the draw lead or other conductors in the bushing. The maximum stresses in the oil at the surface of the shield insulation must be limited to those values normal for insulated conductors and similar components in the same transformer. ABB manufactures shields of this type, which are quoted for and delivered separately. The shields are made of aluminium and are insulated with epoxy or a lining of pressboard. The shield may be mounted on the lower end plate of the bushing, or on the bottom contact of the draw rod. Dimensions and recoendations, see Figs. 18, 19 and 22-26. It is of great importance that the shield is placed in the right position in order to protect the bottom end of the bushing. Guidelines for positioning of the shield are given in Figs. 24 and 26. ABB can also provide assistance with field calculations to confirm the performance of other shielding systems. Quotations for modifications in design and additional parts such as special terminal studs, shields, rod gaps, etc., as well as special tests, are given on request. 3D models and dimension drawings can be downloaded from the ABB website. GOE features A set of concentric tubes are pre stressed and serve as springs which hold the main bushing components together and provide adequate pressure on the gaskets in all expected temperature and load conditions. The annular space formed between the tubes makes an efficient cooling duct for dissipation of the heat, thus improving the current-carrying capacity and thermal stability of the bushing. The bushing is designed to be mounted at an angle of up to 30 to 60 from the vertical. A higher inclination can be obtained on request. The current shall be reduced for horizontal mounting and up to 15 from horizontal. The top housing is made of aluminium and has expansion space for the oil, sufficient for temperature variations in the bushing between -40 and +80 C. Variations in the length of the centre tube and the housing are compensated by a flexible connection inside the top housing. The upper insulator on bushings GOE 1050 and larger are equipped with retaining rings mounted with stainless steel details. GOE(2) features A set of springs in the top housing provides adequate pressure on all gaskets, independently of temperature and load conditions. The bushing is designed to be mounted at an angle not exceeding 30 from the vertical. The top housing has expansion space for the oil sufficient for temperature variations in the bushing between -40 and +80 C. Variations in the lenght of the centre tube are compensated by the flexible cover of the housing. For GOE(2) the upper insulator is cemented to a flange which is bolted to the mounting flange. 4 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Top end nut Flexible connection Top housing Oil level gauge Sealing plug Top end nut Set of springs Top housing Porcelain insulator, air side Sealing plug Oil level gauge Porcelain insulator, air side Transformer oil Pre-stressed tubes Transformer oil Condenser core Condenser core Clamping ring Mounting flange Cemented flange Extension for current transformers Mounting flange Porcelain insulator, oil side Extension for current transformers Porcelain insulator, oil side Bottom end nut Bottom end nut Fig. 1. Transformer bushing type GOE. Fig. 2. Transformer bushing type GOE(2). Features and benefits A complete range and outstanding operational experience from the most demanding applications for more than 30 years. Our unique draw rod system facilitates easy field installation and removal without lowering the oil level. The worlds most used 800 kv bushing. Never any failures in the field. 3D models makes it easy to incorporate the bushing in its context. We use a sealing system proven since 40 years around the world. Our test criteria and margins exceeding international standards. Only extra long creepage shed profile. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 5

Shed profile The shed profile for all GOE bushings is of the anti-fog type with alternating long and short sheds. GOE The shed profile is designed according to IEC 60815. For each pair of sheds, the ratio between nominal creepage distance and the axial length is 4.0. This shed profile is developed and tested specially for heavy pollution. GOE(2) The shed profile is designed according to IEC 60815. For each pair of sheds, the ratio between nominal creepage distance and the axial length is 3.94. 45 65 51 66 R10 R7 R5.5 R8 12 12 R9.5 R9 R7 18 R5.5 18 27 65 10 10 R8 R10 18 R4.5 18 31 70 R4.5 Fig. 3. Shed profile GOE. Fig. 4. Shed profile GOE(2). Coon specifications Application: Transformers Classification: Oil impregnated paper, capacitance graded, outdoor iersed bushing Ambient temperature: +40 C to -50 C, minimum value acc. to temperature class 2 of IEC 60137. Altitude of site: < 1 000 m Level of rain and humidity: 1-2 rain/min. horizontally and vertically, as per IEC 60060-1. Pollution level: According to specified creepage distance and IEC 60815 ( Guide for the selection of insulators in respect of polluted conditions. ) Iersion medium: Transformer oil. Maximum daily mean temperature 90 C. Maximum temporary oil temperature 115 C. Oil level in transformer: Not lower than 30 from the bushing flange. Max. pressure of surrounding medium: 100 kpa over pressure. Markings: Conforming to IEC/ IEEE For conditions exceeding the standard specification above, please consult ABB. 6 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Testing During manufacture and on completion the bushing is subjected to a number of routine tests, according to IEC 60137 and IEEE bushing standards. However, ABB s requirements for acceptance are generally higher than IEC and IEEE standards. A tightness test is carried out on the assembled bushing after the final drying and impregnation. The test is made at an oil overpressure of 180 kpa (1.8 bar) for 12 hours at ambient temperature. No sign of leakage is allowed. Each bushing is subjected to a final electrical routine test. The test is made at room temperature with the lower end of the bushing submerged in oil. Capacitance and tan d are measured in steps up to the power frequency withstand voltage, which is maintained for one minute. The PD value must not exceed 30 pc at the withstand voltage. Capacitance, tan d and internal partial discharge are also measured with decreasing voltage at the same voltage levels as before the one minute test. It is always demonstrated that the PD value is below 5 pc at rated voltage (= 3 times bushing service voltage). Requirements for tan d are max. 0.55 % for U m 362 kv, max. 0.5 % for U m between 362 and 550 kv and max. 0.4% for U m > 550 kv. These measurements are carried out at the same time, and at the same levels, as the tan d test. Bushings with U m 245 kv are routine tested with a dry lightning impulse voltage withstand test, in addition to what has been described. Type tests have been carried out according to IEC 60137 and IEEE. Type test reports are available on request. Test tap All GOE bushings are equipped with a test tap connected to the outer layer of the condenser core. The max. test voltage of the tap is 20 kv, 50 Hz for one minute. Max. service voltage is 6 kv. In connection with an external capacitance the test tap can be used as a voltage tap. The test tap has dimensions according to IEEE Potential tap type A. Test tap adapter For permanent connection of the test tap to measuring circuits, a test tap adapter is required. Catalogue number 2769 522-C. (Pg 16 acc. to DIN 40430) Pr 22.5 Turnable in optional direction Fig. 5. Test tap Fig. 6. Test tap adapter. Oil sampling valve All GOE bushings are equipped with an oil sampling valve. The oil sampling valve can also be used as connection to pressure sensor or pressure switch using the ISO-G 1/4 inside thread. Fig. 7. Oil sampling valve. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 7

Dimensions GOE 250-210 to GOE 950-650 Nominal voltages 52 kv to 170 kv Lightning impulse 250 kv to 950 kv Maximum current 3150 A to 5000 A Catalog Number Bushing Flange extension m Creepage distance D1 L1 L2 L3 L4 L5±5 Mass kg D2 D3 D4 D5 D6 A1 A2 H1 1ZSC902052-AAA GOE 250-210-3150-0.3 0.3 2955 ±80 48 825 ±20 1331 ±25 305 375 685 230 224 350 386 350 300 60 60 20 (6x) -AAB GOE 250-210-3150-0.6 0.6 2955 ±80 48 825 ±20 1331 ±25 605 670 985 240 224 350 386 350 300 60 60 20 6x) -ABA GOE 250-210-5000-0.3 0.3 2955 ±80 38 825 ±20 1331 ±25 305 375 685 270 224 350 386 350 300 60 60 20 (6x) -ABB GOE 250-210-5000-0.6 0.6 2955 ±80 38 825 ±20 1331 ±25 605 670 985 290 224 350 386 350 300 60 60 20 (6x) 1ZSC902072-AAA GOE 380-300-3150-0.3 0.3 2955 ±80 48 825 ±20 1331 ±25 305 375 685 230 224 350 386 350 300 60 60 20 (6x) -AAB GOE 380-300-3150-0.6 0.6 2955 ±80 48 825 ±20 1331 ±25 605 670 985 240 224 350 386 350 300 60 60 20 (6x) -ABA GOE 380-300-5000-0.3 0.3 2955 ±80 38 825 ±20 1331 ±25 305 375 685 270 224 350 386 350 300 60 60 20 (6x) -ABB GOE 380-300-5000-0.6 0.6 2955 ±80 38 825 ±20 1331 ±25 605 670 985 290 224 350 386 350 300 60 60 20 (6x) 1ZSC902145-AAA GOE 650-500-3150-0.3 0.3 4775 ±125 48 1300 ±27 1806 ±33 305 400 835 330 264 400 386 350 350 45 90 20 (8x) -AAB GOE 650-500-3150-0.6 0.6 4775 ±125 48 1300 ±27 1806 ±33 605 700 1135 350 264 400 386 350 350 45 90 20 (8x) -ABA GOE 650-500-5000-0.3 0.3 4775 ±125 38 1300 ±27 1806 ±33 305 400 835 390 264 400 386 350 350 45 90 20 (8x) -ABB GOE 650-500-5000-0.6 0.6 4775 ±125 38 1300 ±27 1806 ±33 605 700 1135 410 264 400 386 350 350 45 90 20 (8x) 1ZSC902170-AAA GOE 950-650-3150-0.3 0.3 6820 ±175 48 1800 ±37 2306 ±42 305 315 835 405 264 400 386 350 350 45 90 20 (8x) -AAB GOE 950-650-3150-0.6 0.6 6820 ±175 48 1800 ±37 2306 ±42 605 615 1135 420 264 400 386 350 350 45 90 20 (8x) Table 1. Dimensions GOE 250 to 950. Catalog Number Bushing Rated current A Rated voltage U m kv, RMS Phaseto-earth voltage U Y kv, RMS Dry lightning impulse LI kv, peak Wet switching impulse SI kv, peak Routine test 1 min dry 50 Hz kv, RMS Wet power frequency AC kv, RMS Dry switching impulse kv, peak Nominal capacitance between conductor and test tap (C 1 ) C 1 ±10% (pf) Max. test load 1 min acc. to IEC 60137 (N) Max permitted load (N) in operation at mounting angle 0 30 60 1ZSC902052-AAA GOE 250-210-3150-0.3 3150 52 30 250 210 120 120 400 448 5700 2800 2300 1700 -AAB GOE 250-210-3150-0.6 3150 52 30 250 210 120 120 400 594 5700 2800 2300 1700 -ABA GOE 250-210-5000-0.3 5000 52 30 250 210 120 120 400 448 5700 2800 2300 1700 -ABB GOE 250-210-5000-0.6 5000 52 30 250 210 120 120 400 594 5700 2800 2300 1700 1ZSC902072-AAA GOE 380-300-3150-0.3 3150 72.5 42 380 300 175 170 550 448 5700 2800 2300 1700 -AAB GOE 380-300-3150-0.6 3150 72.5 42 380 300 175 170 550 594 5700 2800 2300 1700 -ABA GOE 380-300-5000-0.3 5000 72.5 42 380 300 175 170 550 448 5700 2800 2300 1700 -ABB GOE 380-300-5000-0.6 5000 72.5 42 380 300 175 170 550 594 5700 2800 2300 1700 1ZSC902145-AAA GOE 650-500-3150-0.3 3150 145 84 650 500 325 315 650 392 5700 2800 2300 1700 -AAB GOE 650-500-3150-0.6 3150 145 84 650 500 325 315 650 498 5700 2800 2300 1700 -ABA GOE 650-500-5000-0.3 5000 145 84 650 500 325 315 650 392 5700 2800 2300 1700 -ABB GOE 650-500-5000-0.6 5000 145 84 650 500 325 315 650 498 5700 2800 2300 1700 1ZSC902170-AAA GOE 950-650-3150-0.3 3150 245 1) 141 950 650 395 395 750 377 5000 2500 2000 1500 -AAB GOE 950-650-3150-0.6 3150 245 1) 141 950 650 395 395 750 466 5000 2500 2000 1500 Table 2. Data GOE 250 to 950. 1) The bushing can be used for rated voltage 170 kv according to IEC 60137. 8 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

D1 Fig 8. Dimensions GOE 250 to 950. L5 L4 L1 L3 115 25 D3 D2 L2 D4 D5 130 Position of oil sample valve D6 A2 Earthing hole M12 A1 Position of test tap Mounting hole H1 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 9

GOE 1050-750 to GOE 1800-1360 Nominal voltage 245 kv to 550 kv Lightning impulse 1050 kv to 1800 kv Maximum current 2500 A to 5000 A Catalog Number Bushing Flange extension m Creepage distance D1 L1 1ZSC902245-AAA GOE 1050-750-2500-0.3 0.3 8190 ±210 48 2230 ±55 3071 ±60 305 390 1035 755 330 480 485 500 430 45 20 (8x) -AAB GOE 1050-750-2500-0.6 0.6 8190 ±210 48 2230 ±55 3071 ±60 605 655 1335 775 330 480 485 500 430 45 20 (8x) -ABA GOE 1050-750-5000-0.3 0.3 8190 ±210 38 2230 ±55 3071 ±60 305 390 1035 800 330 480 485 500 430 45 20 (8x) -ABB GOE 1050-750-5000-0.6 0.6 8190 ±210 38 2230 ±55 3071 ±60 605 655 1335 860 330 480 485 500 430 45 20 (8x) 1ZSC902362-AAA GOE 1175-850-2500-0.3 0.3 9120 ±240 48 2470 ±55 3311 ±60 305 335 1035 810 330 480 485 500 430 45 20 (8x) -AAB GOE 1175-850-2500-0.6 0.6 9120 ±240 48 2470 ±55 3311 ±60 605 610 1335 830 330 480 485 500 430 45 20 (8x) 1ZSC902420-AAA GOE 1300-1050-2500-0.3 0.3 13745 ±355 48 3620 ±56 4461 ±60 305 320 1035 1070 330 480 485 500 430 45 20 (8x) -AAB GOE 1300-1050-2500-0.6 0.6 13745 ±355 48 3620 ±56 4461 ±60 605 620 1335 1090 330 480 485 500 430 45 20 (8x) -BAA GOE 1425-1150-2500-0.3 0.3 13745 ±355 48 3620 ±56 4461 ±60 305 320 1035 1070 330 480 485 500 430 45 20 (8x) -BAB GOE 1425-1150-2500-0.6 0.6 13745 ±355 48 3620 ±56 4461 ±60 605 620 1335 1090 330 480 485 500 430 45 20 (8x) 1ZSC902550-AAA GOE 1550-1175-2500-0.3 0.3 18020 ±470 48 4710 ±55 5751 ±61 305 310 1285 1995 428 720 565 600 660 30 24 (12x) -AAB GOE 1550-1175-2500-0.6 0.6 18020 ±470 48 4710 ±55 5751 ±61 605 610 1585 2030 428 720 565 600 660 30 24 (12x) -BAA GOE 1675-1300-2500-0.3 0.3 18020 ±470 48 4710 ±55 5751 ±61 305 310 1285 1995 428 720 565 600 660 30 24 (12x) -BAB GOE 1675-1300-2500-0.6 0.6 18020 ±470 48 4710 ±55 5751 ±61 605 610 1585 2030 428 720 565 600 660 30 24 (12x) -CAA GOE 1800-1360-2500-0.3 0.3 18020 ±470 48 4710 ±55 5751 ±61 305 310 1285 1995 428 720 565 600 660 30 24 (12x) -CAB GOE 1800-1360-2500-0.6 0.6 18020 ±470 48 4710 ±55 5751 ±61 605 610 1585 2030 428 720 565 600 660 30 24 (12x) L2 L3 L4 L5±5 Mass kg D2 D3 D4 D5 D6 A1 H1 Table 3. Dimensions GOE 1050 to 1800. Catalog Number Bushing Rated current A Rated voltage U m kv, RMS Phaseto-earth voltage U Y kv, RMS Dry lightning impulse LI kv, peak Wet switching impulse SI kv, peak Routine test 1 min dry 50 Hz kv, RMS Wet power frequency AC kv, RMS Dry switching impulse kv, peak Nominal capacitance between conductor and test tap (C 1 ) C 1 ±10% (pf) Max. test load 1 min acc. to IEC 60137 (N) Max permitted load (N) in operation at mounting angle 0 30 60 1ZSC902245-AAA GOE 1050-750-2500-0.3 2500 362 1) 209 1050 750 505 480 960 373 13000 6500 4300 3100 -AAB GOE 1050-750-2500-0.6 2500 362 1) 209 1050 750 505 480 960 431 13000 6500 4300 3100 -ABA GOE 1050-750-5000-0.3 5000 362 1) 209 1050 750 505 480 960 383 13000 6500 4300 3100 -ABB GOE 1050-750-5000-0.6 5000 362 1) 209 1050 750 505 480 960 431 13000 6500 4300 3100 1ZSC902362-AAA GOE 1175-850-2500-0.3 2500 362 209 1175 850 560 560 950 391 12000 6000 4300 3100 -AAB GOE 1175-850-2500-0.6 2500 362 209 1175 850 560 560 950 465 12000 6000 4300 3100 1ZSC902420-AAA GOE 1300-1050-2500-0.3 2500 420 242 1300 1050 630 n.a. 1155 515 9000 4500 2500 - -AAB GOE 1300-1050-2500-0.6 2500 420 242 1300 1050 630 n.a. 1155 550 9000 4500 2500 - -BAA GOE 1425-1150-2500-0.3 2500 420 242 1425 1150 695 n.a. 1265 522 9000 4500 2500 - -BAB GOE 1425-1150-2500-0.6 2500 420 242 1425 1150 695 n.a. 1265 528 9000 4500 2500-1ZSC902550-AAA GOE 1550-1175-2500-0.3 2500 550 318 1550 1175 750 n.a. 1300 463 13000 6500 4300 1500 -AAB GOE 1550-1175-2500-0.6 2500 550 318 1550 1175 750 n.a. 1300 460 13000 6500 4300 1500 -BAA GOE 1675-1300-2500-0.3 2500 550 318 1675 1300 750 n.a. 1430 464 13000 6500 4300 1500 -BAB GOE 1675-1300-2500-0.6 2500 550 318 1675 1300 750 n.a. 1430 455 13000 6500 4300 1500 -CAA GOE 1800-1360-2500-0.3 2500 550 318 1800 1360 870 n.a. 1500 466 13000 6500 4300 1500 -CAB GOE 1800-1360-2500-0.6 2500 550 318 1800 1360 870 n.a. 1500 457 13000 6500 4300 1500 Table 4. Data GOE 1050 to 1800. 1) The bushing can be used for rated voltage 245 kv according to IEC 60137. 10 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

L5 D1 D3 Fig 9. Dimensions GOE 1050 to 1800. L4 L3 D2 196 28 L2 L1 D4 D5 150 Position of oil sample valve 90 D6 Mounting hole H1 Earthing hole M12 A1 Position of test tap 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 11

GOE 2550 Nominal voltage 800 kv Lightning impulse 2550 kv Maximum current 2500 A Catalog Number Bushing Flange extension m Creepage distance 1ZSC902800-AAA GOE 2550-1675-2500-0.6 0.6 25720 ±670 6690 8051 ±63 605 640 1955 3673 -AAB GOE 2550-1675-2500-0.9 0.9 25720 ±670 6690 8051 ±63 905 940 2255 3733 1ZSC902800-AAC GOE 2550-1600-0.3 0.3 23736 ±712 6690 8051 ±63 305 340 1655 2924 -AAD GOE 2550-1600-0.6 0.6 23736 ±712 6690 8051 ±63 605 640 1955 2974 L1 L2 L3 L4 L5±5 Mass kg Table 5. Dimensions GOE 2550. Catalog Number Bushing Rated current A Rated voltage U m kv, RMS Phaseto-earth voltage U Y kv, RMS Dry lightning impulse LI kv, peak 150 Wet switching impulse SI kv, peak Routine test 1 min dry 50 Hz kv, RMS Dry switching impulse kv, peak Nominal capacitance between conductor and test tap (C 1 ) C 1 ±10% (pf) Max. test load 1 min acc. to IEC 60137 (N) Max permitted load (N) in operation at mounting angle 0 30 60 1ZSC902800-AAA GOE 2550-1675-2500-0.6 2500 800 462 2550 1675 1075 1760 585 12200 6100 2900 - AAB GOE 2550-1675-2500-0.9 2500 800 462 2550 1675 1075 1760 669 12200 6100 2900-1ZSC902800-AAC GOE 2550-1600-0.3 2500 800 462 2550 1620 1000 1760 520 13000 6500 3700 1600 -AAD GOE 2550-1600-0.6 2500 800 462 2550 1620 1000 1760 560 13000 6500 3700 1600 Table 6. Data GOE 2550. Ø616 L5 L2 L4 L1 L3 215 Earthed layer Ø48 Ø780 Position of oil sample valve 90 Earthing hole M12 30 12 mounting holes Ø32 Position of test tap Ø528 28 Ø665 Ø711 Fig 10. Dimensions GOE 2550. Ø565 12 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

GOE 2600 Nominal voltage 1100 kv Lightning impulse 2600 kv Maximum current 2500 A Catalog Number Bushing Flange extension Creepage distance Mass kg m 1ZSC902110-AAA GOE 2600-1950-2500-0.5 0.5 >33000 6000 Table 7. Dimensions GOE 2600. Catalog Number Bushing Rated current A Rated voltage U m Phaseto-earth voltage lightning Dry impulse switching Wet impulse test 5 min Routine dry 50 Hz capacitance Nominal between conductor 1 min acc. to Max. test load IEC 60137 (N) (N) in operation at Max permitted load mounting angle kv, U Y LI SI kv, RMS and test tap (C 1 ) RMS kv, RMS kv, peak kv, peak 0 30 60 C 1 ±10% (pf) 1ZSC902110-AAA GOE 2600-1950-2500-0.5 2500 1100 635 2600 1950 1200 770 8000 2500 - - 2385 ±5 11536 ±80 9585 ±75 Earthing hole M12 12 mounting holes Ø32 30 Position of test tap Ø600 Table 8. Data GOE 2600. 595 300 505 300 38 Earthed layer Ø48 Ø1000 Ø690 Ø755 Ø930 Fig 11. Dimensions GOE 2600. Ø567 150 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 13

GOE(2) Nominal voltage 362 kv to 550 kv Lightning impulse 1175 kv to 1675 kv Maximum current 1600 A Catalog Number Bushing Flange extension m Creepage distance 1ZSC903362-AAA GOE(2) 1175-850-1600-0.3 0.3 9150 ±400 2540 ±4 3425 ±10 300 335 920 565 450 400 -AAB GOE(2) 1175-850-1600-0.6 0.6 9150 ±400 2540 ±4 3425 ±10 600 635 1220 580 450 400 1ZSC903420-AAA GOE(2) 1425-1050-1600-0.3 0.3 11750 ±350 3250 ±4 4135 ±10 300 328 1090 750 500 450 -AAB GOE(2) 1425-1050-1600-0.6 0.6 11750 ±350 3250 ±4 4135 ±10 600 628 1390 770 500 450 1ZSC903550-AAA GOE(2) 1550-1175-1600-0.3 0.3 15200 ±350 4160 ±4 5045 ±10 300 339 1285 1020 500 450 -AAB GOE(2) 1550-1175-1600-0.6 0.6 15200 ±350 4160 ±4 5045 ±10 600 639 1585 1055 500 450 -BAA GOE(2) 1675-1300-1600-0.3 0.3 15200 ±350 4160 ±4 5045 ±10 300 339 1285 1020 500 450 -BAB GOE(2) 1675-1300-1600-0.6 0.6 15200 ±350 4160 ±4 5045 ±10 600 639 1585 1055 500 450 Table 9. Dimensions GOE(2). L1 L2 L3 L4 L5±5 Mass kg D3 D6 Catalog Number Bushing Rated current A Rated voltage U m kv, RMS Phaseto-earth voltage U Y kv, RMS Dry lightning impulse LI kv, peak Wet switching impulse SI kv, peak Routine test 1 min dry 50 Hz kv, RMS Wet power frequency AC kv, RMS Dry switching impulse kv, peak Nominal capacitance between conductor and test tap (C 1 ) C 1 ±10% (pf) Max. test load 1 min acc. to IEC 60137 (N) Max permitted load (N) in operation at mounting angle 0 30 60 1ZSC903362-AAA GOE(2) 1175-850-1600-0.3 1600 362 209 1175 850 560 n.a. 950 379 10000 5000 4400 - -AAB GOE(2) 1175-850-1600-0.6 1600 362 209 1175 850 560 n.a. 950 437 10000 5000 4400-1ZSC903420-AAA GOE(2) 1425-1050-1600-0.3 1600 420 243 1425 1050 695 n.a. 1050 439 10000 5000 4100 - -AAB GOE(2) 1425-1050-1600-0.6 1600 420 243 1425 1050 695 n.a. 1050 488 10000 5000 4100-1ZSC903550-AAA GOE(2) 1550-1175-1600-0.3 1600 550 318 1550 1175 750 n.a. 1175 459 10000 5000 3900 - -AAB GOE(2) 1550-1175-1600-0.6 1600 550 318 1550 1175 750 n.a. 1175 505 10000 5000 3900 - -BAA GOE(2) 1675-1300-1600-0.3 1600 550 318 1675 1300 750 n.a. 1300 459 10000 5000 3900 - -BAB GOE(2) 1675-1300-1600-0.6 1600 550 318 1675 1300 750 n.a. 1300 504 10000 5000 3900 - Table 10. Data GOE(2). 14 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Position of oil sample valve Position of test tap 120 ØD6 L5 L4 Earthed layer L3 Ø50 D3 Ø300 5046 ±10 4160 ±4 158 158 D6 30 Earthing hole M12 12 mounting holes Ø23 Position of oil sample valve Position of test tap 120 30 Earthing hole M12 Fig 12. Dimensions GOE(2) 1175-1425. Ø450 12 mounting holes Ø23 L5 L4 Earthed layer L3 Ø50 Ø500 Ø300 Fig 13. Dimensions GOE(2) 1675. 310 25 310 25 Ø422 Ø462 L1 Ø382 Ø450 Ø382 Ø450 L2 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 15

Current capacity The rated currents specified in this catalogue are based on thermal tests and are in accordance with IEC 60137 and apply to the built-in conductors of the bushings. The GOE bushings conform to the requirements of IEC 60137 and IEEE for currents given in Table 11. Short-time current The rated thermal short-time current (I th ), as defined in IEC 60137 clause 5, is listed in Table 11 for draw rod and fixed bottom end terminal. For draw lead of stranded copper with the area 100 2 the short-time current (I th ) is 9.6 ka for 1 second and 6.8 ka for 2 seconds. For other areas the short-time current is directly proportional to the area. The rated dynamic current (I d ) is 2.5 times the 1 second short-time current. Overload capacity of bushings If the conductor for the bushing is selected with 120 % of the rated current of the transformer, the bushing is considered to be able to withstand overload conditions according to IEC 60076-7 without further clarification or tests. This recoendation complies with IEC 60137. Rated current Current Short-time current Dynamic IEC IEEE current A A I th 1 s ka I th 2 s ka I d peak ka 1600 1450 100 75 250 2500 2100 100 100 250 3150 2700 100 100 250 5000 4250 100 100 250 Table 11. Rated current, short-time current and dynamic current as defined in IEC 60137, for draw rod and fixed bottom end terminal. 16 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Connection details The oil side connection can be made with either a draw-rod system or a draw-lead system. For the air side connection the same outer terminals are provided for both systems. When ordering, please specify the items stated below. Draw rod system Fig. 14: The centre tube of the bushing is used as current conductor. Fig. 15: The transformer leads are fitted with cable lugs, which are bolted to a bottom contact. Fig. 16: This contact is drawn against the lower end of the bushing tube by a thin steel draw rod. Fig. 17: During installation on the transformer, the upper end of this rod is bolted to a spring device beneath the outer terminal, which consists of two concentric tubes of different materials and is so designed that it gives the required contact load at all temperatures. Bottom contacts with 4 or 6 threaded holes for cable lugs are available. The bottom contacts are made of copper and have rounded edges, so that they may be used without any shield for low insulation levels (BIL <450 kv). At the level of the flange the draw rod is split into two parts. If required to meet the transport conditions, a joint at any desired level below the flange can be offered on request. The lower part with contact end shield can then be secured to the cover during transport and storage of the transformer. Type of draw rod GOE type BIL GOE Cat. No. GOE(2) Cat. No. Lower draw rod 1) 250-2600 LF 170 059 LF 170 098 Upper draw rod 2) 250-2600 LF 170 057 LF 170 097 Table 12. Ordering particulars for draw rod system. 1) Lower draw rod includes bottom contact, guiding cone and draw rod up to bushing flange level. 2) Upper draw rod includes the complete draw rod above mounting flange level and the temperature compensation device. Fig. 14. Fig. 15. Fig. 16. Fig. 17. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 17

Outer terminal 150 D2 Outer terminal 125 D2 H2 H2 Threaded hole M8 for pulling wire L2 Threaded hole M8 for pulling wire L2 M16 25 60 Mounting flange M16 25 Mounting flange 60 Additional joint on request H1 240 L5 N1 = Number of holes M12, equipped with thread insert with screw lock, depth 20, for cable lugs. Additional joint on request 110 H1 L5 58 39 65 50 65 51 65 51 N1=4 125 Small bottom contact Large bottom contact N1=6 Small N1=4 bottom contact N1=4 110 Large bottom contact Fig. 18. Draw rod system for GOE. For all currents up to rated current of the bushing. Selection as per Table 12. Fig. 19. Draw rod system for GOE(2). For all currents up to rated current of the bushing. Selection as per Table 12. This system has been supplied by ABB since the seventies with an excellent service record and has the following advantages compared to other methods used for high currents: No hand holes required in the transformer tank. Easy bushing installation and removal no connection work inside the transformer at site. No special supports required in the transformer as is the case with plug contacts. Perfect guiding of the bushing into the transformer. The lower end shield may be fixed to the contact and will thus be correctly positioned with respect to the lower end plate of the bushing. No mechanical forces exerted on the leads from the transformer windings at any time. 18 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Draw lead system GOE Suitable copper terminals for flexible draw leads are available for currents up to 1600 A. The terminal system consists of a two-part cable connector with a hole for brazing of the cable or cables. The two parts are screwed together in such a manner that normal tolerances in the cable and bushing lengths can be compensated. The connector is fastened by a hexagon nut to a copper plate placed at the top of the bushing. The GOE outer terminal stud is placed on top of this plate. GOE(2) The terminal system is made in one piece for connection of a draw lead. The terminal is attached by means of a divided ring at the top of the centre tube. When mounting the outer terminal, the ring becomes locked. Current, A Complete inner terminal Bushing type D3 D9 Min. inner diameter Conductor area Mass D1 of bushing, 2 IEC IEEE Cat. No. kg GOE 0 1) 35 38 - - - LF 170 056 -A 3.2 15 35 38 50 205 200 -B 3.2 95 390 370 30 35 38 150 615 540 -C 3.2 285 1000 830 40 45 48 450 1300 1100 -D 4.4 600 1600 1360 0 1) 45 48 - - - -E 4.4 GOE(2) 0 1) - - - - - LF 170 091 -A 1.1 15 - - 95 300 260 -B 1.0 30 - - 285 630 540 -C 0.9 42 - - 740 1300 1110 -D 0.7 Table 13. Inner terminals. 1) With pilot hole D=5 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 19

150 D2 125 D2 Outer terminal H2 Threaded hole M8 for pulling wire Outer terminal H2 Threaded hole M8 for pulling wire 53 L2 350 End of cable D3 46 L2 30 D9 D3 End of cable Fig. 20. Draw lead system, LF 170 056, and outer terminal for GOE. Selection as per Tables 13 and 14. Fig. 21. Draw lead system, LF 170 091, and outer terminal for GOE(2). Selection as per Tables 13 and 14. 20 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Outer terminal The outer terminal consists of a cylindrical stud. The mounting arrangements are the same for all GOE bushings, regardless of size, current rating and internal connection system. Copper and aluminium studs are available. The stud is first fastened to the bushing top with M10 bolts, which give the proper electrical contact. The contact surface is located inside the gasket and is thus well protected from corrosion. Finally, the retainer ring with the gasket is pressed against the stud by means of M8 bolts. The terminal stud assembly consists of a stud, a retainer ring, a gasket, bolts and washers. The electrical contact function and the sealing function are completely separated. Bushing type Article No. Material D2 () H2 () Max. rated current (A) Mass (kg) GOE LF170073-A Al 60 125 2500 3 LF170073-B Cu 60 125 4000 8 LF170073-G Cu/Ag 60 125 4000 8 LF170073-L Cu/Sn 60 125 4000 8 LF170073-BA Cu/Ag Thread 2-12UN 125 3000 7.5 LF170073-AA Cu 96 125 5000 9 GOE(2) LF170090-A Al 30 125 1250 1 LF170090-B Al 60 125 1600 1.8 LF170090-C Cu 30 125 1600 2.8 LF170090-E Cu 60 125 1600 5.1 LF170090-G Cu/Ag Thread 2-12UN 125 1600 3.9 Table 14. Outer terminals. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 21

End-shields The maximum stresses in the oil at the surface of the shield insulation and the parts surrounding the bushing must be limited to those values normal for insulated conductors and other similar components in the same transformer. The withstand voltages in a specific case depend upon many factors beyond the control of the bushing manufacturer. Therefore the configurations and distances given below are only intended as guidelines. ABB can also provide assistance with field calculations to confirm the compatibility between the transformer and our bushings. R min 5 Edges within this area should be rounded to R min =5 45 Earthed layer 60 A 1000 A 500 Shield -X/-XP Shield -V/-VP H6 R1 H4 H5 D5 D4 R3 R2 A = Distance to flat surface e.g. tank or core clamp 0 0 0 No shield 500 1000 Shield -U/-UP 500 1500 2000 1000 2500 (kv) U (kv) LI U = Power frequency LI = Lightning impulse Fig. 23. Recoended minimum distance A for different shields and test voltages. ø102 ø125 20 60 60 18 13 Shield mounted on the bushing Large bottom contact N1= 6 Shield mounted on the draw rod bottom contact. (Not possible for small bottom contact with N1 = 4. See Fig. 18.) Fig. 22. Recoendations for positioning, type GOE. Fig. 24. Mounting alternatives, type GOE. To be used Dimensions according to Fig. 18, Mass Cat. No. Epoxy Pressboard with GOE D4 D5 H4 H5 H6 R1 R2 R3 kg insulated insulated 1) 250-1425 262 174 265 170 90 492 30 8 2.1 LF 170 046 -U -UP 1550-1800 352 207 365 240 120 351 24 10 2.5 LF 170 046 -V -VP 2550 420 230 420 290 125 533 44 25 3.2 LF 170 046 -X -XP 2600 500 260 500 350 145 652 57 30 6.4 LF 170 046 -CB -CBP Table 15. Insulated shield. 1) All dimensions refer to the epoxy insulated shield, which is used as a base. The thickness of the pressboard is 3 for -UP and -VP, and 6 for -XP and -CBP. 22 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

R min 5 45 60 Edges within this area should be rounded to R min =5 Shield mounted on the bushing Earthed layer Large bottom contact N1=4 A Shield mounted on the draw rod bottom contact. (Not possible for small bottom contact. See Fig. 19.) H6 R1 Fig. 26. Mounting alternatives, type GOE(2). H4 H5 R3 D5 D4 R2 A = Distance to flat surface e.g. tank or core clamp ø110 ø87 60 60 ø13 ø18 20 Fig. 25. Recoendations for positioning, type GOE(2). To be used Dimensions according to Fig. 21, Mass Cat. No. Epoxy Pressboard with GOE(2) D4 D5 H4 H5 H6 R1 R2 R3 A kg insulated insulated 1) 1175 250 142 230 163 62 230 25 8 370 1.5 LF 170 092 -A -C 1425 258 142 265 180 80 350 32 9 430 1.8 LF 170 092 -K -L 1550-1675 258 142 265 180 80 350 32 9 470 1.8 LF 170 092 -K -L Table 16. Insulated shield. 1) All dimensions refer to the epoxy insulated shield, which is used as a base. The thickness of the pressboard is 3. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 23

Ordering particulars When ordering, please state the following: Type and catalogue number for bushing. Catalogue number for the outer terminal, or if a nonstandard terminal is requested: material, diameter D2 and height H2. Specify draw rod or draw lead system. If a draw rod system is chosen, the size of the bottom contact (small or large) must be specified. If a draw lead system is chosen, the full catalogue number must be given. Catalogue number for insulated shield. (A shield is recoended for BIL 450 kv and higher.) Other special requirements. See the ordering examples: Example 1 Bushing: GOE 650-500-3150-0.3, 1ZSC902145-AAA Outer terminal: LF 170 073-A or -B Inner connections: Draw lead, LF 170 056-A Insulated shield: Epoxy insulated, LF 170 046-U Example 2 Bushing: GOE 1550-1175-2500-0.6, 1ZSC902550-AAB Outer terminal: LF 170 073-A or -B Inner connections: Draw rod, upper part LF 170 057, lower part LF 170 059, small contact (On request the lower part of the draw rod can be sent separately at an earlier delivery date.) Insulated shield: Pressboard coated, LF 170 046-VP Example 3 Bushing: GOE 1300-1050-2500-0.3, 1ZSC902420-AAA Outer terminal: Silver plated, D2=50, H2=100 Inner connections: Draw rod, upper part LF 170 057, lower part LF 170 059, small contact (On request the lower part of the draw rod can be sent separately at an earlier delivery date.) Insulated shield: Pressboard coated, LF 170 046-VP Other requirements: Test voltage 690 kv Tan d over C2<1.0 % 24 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Packing The bushings are delivered in wooden crates; the same crate used for all flange extensions. When end shields are ordered, they will be delivered together with the bushings in the same crates. All crates are heat-treated according to ISPM15. Bushing Wooden crate L () B () H () Mass (kg) GOE 250-380 3140 540 640 125 GOE 650 3740 590 640 155 GOE 950 4250 590 640 172 GOE 1050 5240 670 750 244 GOE 1175 5490 670 750 253 GOE 1300-1425 6640 670 750 299 GOE 1550-1800 8350 930 1100 728 GOE 2550 11360 990 1200 1030 GOE 2600 14670 1490 1570 2580 GOE(2) 1175 5440 640 690 235 GOE(2) 1425 6350 690 720 289 GOE(2)1550-1675 7440 690 720 334 L B H Fig. 27. Packing crate. 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 25

Additional GOE and GOE(2) bushings available on request The following types of bushings are available on request. Keep in mind that lead times may be longer than for the standard range. Bushings are also available according to certain established customer specifications. For full details, please contact ABB. All GOE bushings with rated voltage from 52 kv to 800 kv can be supplied with a current rating of 5000 A. Bushing type Catalogue Number Insulator colour Brown/ Light grey Rated current A Flange extension Rating plate data Rated voltage U m kv, RMS Phase-toearth voltage U Y kv, RMS Dry lightning impulse LI kv, peak Wet switching Routine test impulse 1 min dry SI 50 Hz kv, peak kv, RMS GOE 250-210 LF 121 051 -A/-AA 3150 0.6 52 52 250 210 120 -B/-AB 3150 0.3 -C/-AC 5000 0.6 -D/-AD 5000 0.3 GOE 380-300 LF 121 052 -A/-AA 3150 0.6 123 84 450 300 185 -B/-AB 3150 0.3 -C/-AC 5000 0.6 -D/-AD 5000 0.3 GOE 450-400 LF 121 053 -A/-AA 3150 0.6 170 123 550 400 260 -B/-AB 3150 0.3 -C/-AC 5000 0.6 -D/-AD 5000 0.3 GOE 650-500 LF 121 054 -A/-AA 3150 0.6 245 155 650 500 325 -B/-AB 3150 0.3 -C/-AC 5000 0.6 -D/-AD 5000 0.3 GOE 900-650 LF 121 055 -A/-AA 3150 0.6 245 170 950 650 395 -B/-AB 3150 0.3 -C/-AC 5000 0.6 -D/-AD 5000 0.3 GOE 1050-750 LF 121 063 -A/-AA 2500 0.6 362 220 1050 750 505 -B/-AB 2500 0.3 -C/-AC 2500 0 GOE 1175-850 LF 121 061 -A/-AA 2500 0.6 362 220 1175 850 530 -B/-AB 2500 0.3 -C/-AC 2500 0 -D/-AD 5000 0.6 -E/-AE 5000 0.3 -F/-AF 5000 0 GOE(2) 1175-850 LF 121 560 -A/-AA 1600 0.6 362 220 1175 850 560 -B/-AB 1600 0.3 GOE 1300-1050 LF 121 071 -A/-AA 2500 0.6 420 245 1425 1050 630 -B/-AB 2500 0.3 26 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

L5 L2 Fig. 28. Dimensions. Other data for information Max. test load 1 min acc. to Max permitted load (N) in operation at mounting angle Dimensions (Fig. 28) Wet power Dry switching Nominal capacitance IEC 60137 (N) frequency AC impulse kv, peak between conductor and test tap (C 1 ) kv, RMS C 1 ±10% (pf) 0-30 -60 L2 L5 Creepage distance 120 400 810 / 594 5700 2800 2300 1700 1060 985 1425 ±40 685 985 685 170 550 594 / 448 5700 2800 2300 1700 1335 985 2955 ±65 685 985 685 240 650 543 / 423 5000 2500 2000 1500 1630 985 3355 ±90 685 985 685 315 650 498 / 392 5700 2800 2300 1700 1810 1135 4775 ±105 835 1135 835 395 750 448 / 365 5000 2500 2000 1500 2310 1135 6820 ±150 835 1135 835 480 960 430 / 383 / 308 13000 6500 4300 3100 3070 1335 8190 ±185 1035 735 540 950 490 / 420 / 345 12000 6000 4300 3100 3310 1335 9120 ±205 1035 735 1335 1035 735 560 1030 470 / 407 10000 5000 4400-3426 1225 9150 ±400 925 650 1050 575 / 560 10000 5000 3000 1500 3225 1335 10290 ±265 1035 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 27

Bushing type Catalogue Number Insulator colour Brown/ Light grey Rated current A Flange extension Rating plate data Rated voltage U m kv, RMS Phase-toearth voltage U Y kv, RMS Dry lightning impulse LI kv, peak Wet switching Routine test impulse 1 min dry SI 50 Hz kv, peak kv, RMS GOE 1300-1150 LF 121 071 -C/-AC 2500 0.6 420 245 1425 1175 680 -D/-AD 2500 0.3 GOE(2) 1425-1050 LF 121 570 -A/-AA 1600 0.6 420 243 1425 1050 690 -B/-AB 1600 0.3 GOE 1550-1050 LF 121 072 -A/-AA 2500 0.6 550 318 1550 1050 750 -B/-AB 2500 0.3 -C/-AC 2500 0 GOE 1675-1175 LF 121 073 -A/-AA 2500 0.6 550 318 1675 1175 750 -B/-AB 2500 0.3 -C/-AC 2500 0 GOE 1675-1300 LF 121 073 -D/-AD 2500 0.6 550 318 1675 1300 750 -E/-AE 2500 0.3 -F/-AF 2500 0 GOE(2) 1675-1300 LF 121 580 -A/-AA 1600 0.6 550 318 1675 1300 750 -B/-AB 1600 0.3 GOE 1800-1300 LF 121 074 -A/-AA 2500 0.6 550 318 1800 1300 800 -B/-AB 2500 0.3 -C/-AC 2500 0 GOE 2100-1425 LF 121 081 -A/-AA 2500 0.6 800 485 2100 1425 970 -B/-AB 2500 0.3 GOE 2550-1550 LF 121 082 -A/-AA 2500 0.6 800 485 2550 1550 1000 -B/-AB 2500 0.3 -C/-AC 2500 0 GOE 2550-1600 LF 121 083 -A/-AA 2500 0.6 800 485 2550 1620 1000 -B/-AB 2500 0.3 -C/-AC 2500 0 28 Technical guide GOE 1ZSE 2750-105 en, Rev. 8

Other data for information Max. test load 1 min acc. to Max permitted load (N) in operation at mounting angle Dimensions (Fig. 28) Wet power Dry switching Nominal capacitance IEC 60137 (N) frequency AC impulse kv, peak between conductor and test tap (C 1 ) kv, RMS C 1 ±10% (pf) 0-30 -60 L2 L5 Creepage distance 650 1175 575 / 545 9000 4500 2500-4460 1335 13745 ±300 1035 690 1140 532 / 474 10000 5000 4100-4136 1390 11750 ±350 1090 660 1050 457 / 390 / 342 16000 8000 4700 2500 3965 1585 10130 ±260 1285 985 730 1300 521 / 440 / 433 16000 8000 4700 2500 4460 1585 11700 ±300 1285 985 790 1300 500 / 490 / 450 13000 6500 4300 1500 5260 1585 13380 ±330 1285 985 750 1410 525 / 482 10000 5000 3900-5046 1585 15200 ±350 1285 800 1300 500 / 490 / 450 13000 6500 4300 1500 5260 1585 13380 ±330 1285 985 900 1550 600 / 575 15700 7850 5400 3600 6265 1955 16630 ±420 1655 950 1675 574 / 522 / 476 14000 7000 4400 2500 7065 1955 18320 ±460 1655 1355 1000 1760 600 / 550 / 506 13000 6500 3700 1600 7555 1955 23736 ±500 1655 1355 1ZSE 2750-105 en, Rev. 8 Technical guide GOE 29

Contact us ABB AB Components SE-771 80 Ludvika, Sweden Phone: +46 240 78 20 00 Fax: +46 240 121 57 E-Mail: sales@se.abb.com www.abb.com/electricalcomponents Copyright 2015 ABB, All rights reserved. 1ZSE 2750-105 en, Rev. 8, 2015-04-15