Code Reference Competitive Comparison Product Selection Guide Water Tempering Valves LavSafe L111, MMV 1170, L1170 USG-B w a t t s. c o m
Table of Contents PAGE Code Reference Guide International Plumbing Code (IPC) - Tempering Valves... 2-3 International Residential Code (IRC) - Tempering Valves... 4-5 Uniform Plumbing Code (UPC) - Tempering Valves... 6-7 Product Selection Guide for ASSE 1017, 1069 & 1070... 8-9 for ASSE 1070... 10-11 for ASSE 1017... 12-13
Watts Code Reference Guide International Plumbing Code (IPC) - Tempering Valves Application Watts Listed Products IPC - 2003 IPC - 2006 IPC - 2009 State Adoption By Series CT, KS, MO, NY, VT AR, AZ, CO, DC, FL, GA, ID, MI, MS, NC, ND, OH, SC, UT AL, DE, MD, NH, OK, PA, RI, UT, VA, WV Public Lavatories USG-B, MMV, L111, LavSafe No reference to tempering valves or ASSE standards. 416.5 Tempered water for public hand-washing facilities. Tempered water shall be delivered from public hand-washing facilities through an approved water temperature limiting device that conforms to ASSE 1070. Bathtubs and Whirlpools MMV, L111 No reference to tempering valves or ASSE standards. 424.5 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120 F (49 C) by water temperature limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower valve in accordance with section 424.3. 416.5 Tempered water for public hand-washing facilities. Tempered water shall be delivered from public hand-washing facilities. Tempered water shall be delivered through an approved water temperature limiting device that conforms to ASSE 1070 or CSA B125. 424.5 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120 F (49 C) by water temperature limiting device that conforms to ASSE 1070 or CSA B125.3, except where such protection is otherwise provided by a combination tub/shower valve in accordance with section 424.3. Shower and Tub-Shower E800SG, E800MSG (WBT) 424.3 Shower valves. Shower and tub-shower combination valves shall be balanced pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or CSA B125. Gang Showers MMV, L111 424.3 Shower valves (cont'd). Multiple (gang) showers supplied with a single tempered water supply pipe shall have the water supply for such showers controlled by a master thermostatic mixing valve complying with ASSE 1017. Shower and tub-shower combination valves and master thermostatic mixing valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120 F (49 C), which shall be field adjusted in accordance with the manufacturer's instructions. 424.3 Individual shower valves. Individual shower valves and tub-shower combinations valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or CSA B125 and shall be installed at the point-of-use. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120 F (49 C), which shall be filed adjusted in accordance with the manufacturer's instructions. In-line thermostatic valves shall not be utilized for compliance with this section. 424.4 Multiple (gang) showers. Multiple (gang) showers supplied with a singletempered water supply pipe shall have the water supply for such showers controlled by an approved automatic temperature control mixing valves that conforms to ASSE 1069 or CSA B125, or each shower head shall be individually controlled by a balanced-pressure/thermostatic valve that conforms to ASSE 1016 or CSA B125 and is installed at the point-of-use. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120 F (49 C), which shall be field adjusted in accordance with the manufacturer's instructions. 424.3 Individual shower valves. Individual shower valves and tub-shower combinations valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or CSA B125.1 and shall be installed at the point-of-use. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120 F (49 C), which shall be filed adjusted in accordance with the manufacturer's instructions. In-line thermostatic valves shall not be utilized for compliance with this section. 424.4 Multiple (gang) showers. Multiple (gang) showers supplied with a single-tempered water supply pipe shall have the water supply for such showers controlled by an approved automatic temperature control mixing valves that conforms to ASSE 1069 or CSA B125, or each shower head shall be individually controlled by a balanced-pressure/thermostatic valve that conforms to ASSE 1016 or CSA B125 and is installed at the point-of-use. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120 F (49 C), which shall be field adjusted in accordance with the manufacturer's instructions. Temperature-Actuated Flow Reduction WHT115 424.5 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substitute for the balanced pressure, thermostatic or combination shower valves required in Section 424.3. 424.7 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substitute for the balanced pressure, thermostatic or combination shower valves required in Section 424.3. 424.7 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substitute for the balanced pressure, thermostatic or combination shower valves required in Section 424.3. Bidet MMV, L111 No reference to tempering valves or ASSE standards. 408.3 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110 F (43 C) by a water temperature limiting device conforming to ASSE 1070. 408.3 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110 F (43 C) by a water temperature limiting device conforming to ASSE 1070. Water Heater 1170, MMV, N170-M3 501.2 Water heater as space heater. Where a combination potable water heating and space heating system requires water for space heating at temperatures higher than 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140 F (60 C) or less. The potability of the water shall be maintained throughout the system. Tankless Heaters 1170, MMV, N170-M3 501.6 Water temperature control in piping from tankless heaters. The temperature of water from tankless water heaters shall be a maximum of 140 F (60 C) when intended for domestic uses. This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3. 501.2 Water heater as space heater. Where a combination potable water heating and space heating system requires water for space heating at temperatures higher than 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140 F (60 C) or less. The potability of the water shall be maintained throughout the system. 501.6 Water temperature control in piping from tankless heaters. The temperature of water from tankless water heaters shall be a maximum of 140 F (60 C) when intended for domestic use This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3. 501.2 Water heater as space heater. Where a combination potable water heating and space heating system requires water for space heating at temperatures higher than 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140 F (60 C) or less. The potability of the water shall be maintained throughout the system. 501.6 Water temperature control in piping from tankless heaters. The temperature of water from tankless water heaters shall be a maximum of 140 F (60 C) when intended for domestic use. This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3. Temperature-Actuated Mixing Valves 1170, MMV, N170-M3 613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves, which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017. 613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017. 613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017. Hot Water Supply System 1170, MMV, N170-M3 607.1 Where required. In nonresidential occupancies, hot water or tempered water shall be supplied for bathing and washing purposes. Tempered water shall be delivered from accessible hand-washing facilities. 607.1 Where required. In nonresidential occupancies, tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water to a maximum of 110 F (43 C). This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3. 607.1 Where required. In nonresidential occupancies, hot water shall be supplied for culinary purposes, cleansing, laundry or building maintenance purposes. Tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water to a maximum of 110 F (43 C). This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3. 2 3
Watts Code Reference Guide International Residential Code (IRC) - Tempering Valves Application Watts Listed Products IRC - 2003 IRC - 2006 IRC - 2009 State Adoption By Series CT, HI, IN, KS, MA, NY, VT AK, AR, DC, FL, GA, HI, ID, KY, LA, MI, MN, MS, MT, ND, NJ, NV, OH, OR, SC, WY CA, IA, MD, ME, NH, OK, PA, RI, TN, UT, VA, WA, WV Bathtubs and Whirlpools MMV, L111 P2713 Bathtubs and P2720 Whirlpool Tubs (tempering not addressed) P2713.3 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120 F (49 C) by a water temperature-limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/ shower valve in accordance with Section P2708.3. P2713.3 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120 F (49 C) by a water temperature-limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower valve in accordance with Section P2708.3. Shower and Tub-Shower E800SG, E800MSG (WBT) P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with a high limit stop in accordance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water temperature to a maximum of 120 F (49 C). P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with a high limit stop in accordance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water temperature to a maximum of 120 F (49 C). In-line thermostatic valves shall not be used for compliance with this section. P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with a high limit stop in accordance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water temperature to a maximum of 120 F (49 C). In-line thermostatic valves shall not be used for compliance with this section. Bidet MMV, L111 P2721 Bidet Installations (tempering not addressed) P2721.2 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110 F (43 C) by a water temperature-limiting device that conforms to ASSE 1070. P2721.2 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110 F (43 C) by a water temperature-limiting device that conforms to ASSE 1070. Water Heater 1170, MMV, N170-M3 P2802.2 Temperature control. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140 F (60 C) or less for domestic uses. P2802.3 Scald Protection. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140 F (60 C), a means such as a mixing valve shall be installed to temper water for domestic uses. P2802.2 Temperature control. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140 F (60 C) or less for domestic uses. P2802.2 Temperature control. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140 F (60 C), a master thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140 F (60 C) or less for domestic uses. 4 5
Watts Code Reference Guide Uniform Plumbing Code (UPC) - Tempering Valves Application Watts Listed Products UPC - 2003 UPC - 2006 UPC - 2009 State Adoption By Series AK, ID, NV, SD CA, HI, MT, NM, OR, Houston, Topeka IA, WA, St. Louis (CA, ID, MT to adopt 2009) Public Lavatories USG-B, MMV, L111, LavSafe 414.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered for public-use lavatories shall be limited to a maximum temperature of 120 F (49 C). The water heater thermostat shall not be considered a control for meeting this provision. 413.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered for public-use lavatories shall be limited to a maximum temperature of 120 F (49 C). The water heater thermostat shall not be considered a control for meeting this provision. 413.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered for public-use lavatories shall be limited to a maximum temperature of 120 F (49 C) by a device that conforms to ASSE 1070 or CSAB125.3. The water heater thermostat shall not be considered a control for meeting this provision. Bathtubs and Whirlpools MMV, L111 415.0 Whirlpool Bathtubs (tempering not addressed). 421.0 Limitation of Hot Water in Bathtubs. The maximum hot water temperature discharging from the bathtub filler shall be 120 F (49 C). 414.5 Limitations of Hot Water in Bathtubs and Whirlpool Bathtubs. The maximum hot water temperature discharging from the bathtub and whirlpool bathtub filler shall be limited to 120 F (49 C). The water heater thermostat shall not be considered a control for meeting this provision. 414.5 Limitations of Hot Water in Bathtubs and Whirlpool Bathtubs. The maximum hot water temperature discharging from the bathtub and whirlpool bathtub filler shall be limited to 120 F (49 C) by a device that conforms to ASSE 1070 or CSA B125.3. The water heater thermostat shall not be considered a control for meeting this provision. Shower and Tub-Shower E800SG, E800MSG (WBT) 420.0 Shower and Tub-Shower Combinations Showers and tub-shower combinations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016. 418.0 Shower and Tub-Shower Combination Control Valves. Showers and tub-shower combinations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016. 418.0 Shower and Tub-Shower Combination Control Valves. Showers and tubshower combinations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016. Gang Showers MMV, L111 420.0 (cont'd)...gang showers, when supplied with a single temperaturecontrolled water supply pipe, may be controlled by a master thermostatic mixing valve in lieu of individually controlled pressure balance, thermostatic, or combination pressure balance/thermostatic mixing valves. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instructions to deliver a maximum mixed water setting of 120 F (49 C). The water heater thermostat shall not be considered a suitable control for meeting this provision. 418.0 (cont'd)...gang showers, when supplied with a single temperature-controlled water supply pipe, may be controlled by a master thermostatic mixing valve in lieu of individually controlled pressure balance, thermostatic, or combination pressure balance/thermostatic mixing valves. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instructions to deliver a maximum mixed water setting of 120 F (49 C). The water heater thermostat shall not be considered a suitable control for meeting this provision. 418.0 (cont'd)...gang showers, when supplied with a single temperature-controlled water supply pipe, shall be controlled by a mixing valve that conforms to ASSE 1069. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instructions to deliver a maximum mixed water setting of 120 F (49 C). The water heater thermostat shall not be considered a suitable control for meeting this provision. Bidet MMV, L111 417.0 Bidets (tempering not addressed) 416.0 (tempering not addressed). 416.3 Limitation of Water Temperature in Bidets. The maximum hot water temperature discharging from a bidet shall be limited to 110 F (43 C) by a device that conforms to ASSE 1070 or CSA B125.3.The water heater thermostat shall not be considered a suitable control for meeting this provision. Water Heater 1170, MMV, N170-M3 505.4 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturer's instructions. 505.5 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturers instructions. 505.5 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturers instructions. Temperature Actuated Mixing Valves 1170, MMV, N170-M3 Table 14-1 Referenced Standards. ASSE 1017-1998 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. Hot Water Supply System 1170, MMV, N170-M3 Table 14-1 Referenced Standards. ASSE 1017-1998 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. 6 7
Product Selection Guide Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Caleffi Leonard Point-of-Use/Source for ASSE 1017, 1069 & 1070 MMV AM-1 1070 ZW1070 34B - MVB Heatguard 160 Aqualine 5213 270, 370 ASSE Standard Listing 1017, 1069, 1070 1017, 1070 1070 1017, 1070 1069, 1070 1017, 1070 1070 1017, 1070 GPM @ 45 psid 1 2" 13 10 10 17 9 14 13 11 3 4" 13 10 10 17 10 14 13 12 1" 13 10 10 17 11 not available 13 not available Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 1.0 gpm 1.0 gpm 0.5 gpm 1.0 gpm 0.5 gpm Outlet Temperature Range 80-120 F 70-120 F 95-115 F 80-120 F 95-115 F 60-140 F 85-120 F not stated Cold Water Inlet Temperature 39-85 F not stated 40-75 F 39-85 F 40-80 F 39-80 F 39-85 F not stated Hot Water Inlet Temperature max. 200 F max. 212 F 120-195 F 120-180 F max. 195 F 120-180 F 120-185 F max. 200 F Maximum Working Pressure 150 psi 150 psi 145 psi 150 psi 145 psi 150 psi 140 psi 125 psi Approach Temperature (outlet maximum within F of inlet HW supply) 5 F 3 F not stated 5 F not stated 10 F 9 F 5 F Lockable Temperature Setting Yes Yes Yes Yes Yes Yes Yes Standard Unions Order Separate Yes Yes Order Separate Yes Yes No Standard Checks Order Separate Yes Yes Order Separate Yes Yes Yes Lead Free* No Yes Yes No No Yes Yes Standard Filters No No Yes Order Separate Yes No No Connection Type Threaded Yes Yes Yes Yes Yes Yes Yes - MIPS Sweat Yes Yes Yes Yes Yes Yes Yes CPVC Yes Yes Yes Yes No NO No PEX Yes Yes Yes Yes Yes No No Quick Connect No No No Yes No No No Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant 22-Sep-10 *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. 8 9
Product Selection Guide Point-of-Use for ASSE 1070 Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Leonard USG-B LavSafe UMV ZW3870T 34D - MVD Heatguard 145 5-210-CK 170 ASSE Standard Listing 1070 1070 1070 1070 1070 1070 1017, 1070 1070 GPM @ 45 psid 2.5 gpm 2.2 gpm 3.0 gpm 3.0 gpm 3.5 gpm 4.5 gpm 5.0 gpm 4.5 gpm Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm Outlet Temperature Range 80-120 F 60-120 F 80-120 F 95-115 F 85-120 F 95-115 F 105-120 F not stated Cold Water Inlet Temperature 39-80 F 39-80 F not stated 40-75 F not stated 39-80 F 39-80 F not stated Hot Water Inlet Temperature 120-180 F 120-180 F max. 180 F 120-195 F max. 210 F max. 195 F 120-180 F max. 212 F Maximum Working Pressure 150 psi 125 psi 150 psi 145 psi 125 psi 145 psi 125 psi 125 psi Approach Temperature (outlet maximum within F of inlet HW supply) 5 F 5 F 15 F not stated not stated not stated 10 F 5 F Lead Free* No Yes Yes No No Yes WaterSense n/a n/a n/a n/a n/a n/a n/a Lockable Temperature Setting Yes Yes Yes Yes Yes Yes Integrated 4-port Configuration w/internal Cold Water Bypass n/a No - Add on No No No No No - 4th optional Standard Checks Yes Yes Yes Yes Yes Yes Standard Filters No No No No Yes No - 4th optional Connection Type 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant BAA/ARRA Compliant 22-Sep-10 *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. 10 11
Product Selection Guide Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Caleffi Leonard Point-of-Source for ASSE 1017 1170, L1170 AM-1 ZW1017 34A - MVA 110-D 110-HX 115-D 115-H 5-120, 5-130, 5-140 Aqualine 521 270, 370 ASSE Standard Listing 1017 1017 1017 1017 1017 1017 1017, 1070 1017 1017, 1070 GPM @ 45 psid 1 2" 23 8 18 23 17 17 not available not available not stated 14 20 11 3 4" 23 12 18 23 18 18 28 28 not stated 14 20 12 1" 23 16 18 23 19 19 32 32 not stated not available 20 not available Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 1.0 gpm 1.0 gpm 2.5 gpm 2.5 gpm not stated 0.5 gpm not stated 0.5 gpm Outlet Temp. Range Standard 90-160 F 100-145 F 80-165 F 130-180 F 95-120 F 95-176 F 95-120 F 95-140 F 85-160 F 60-140 F 85-150 F not stated Low 60-120 F 60-100 F 95-131 F 85-140 F not stated Cold Water Inlet Temperature 39-85 F not stated 40-75 F 39-80 F 39-80 F 39-80 F 40-80 F 40-80 F 40-80 F 39-85 F not stated max. 200 F Hot Water Inlet Temperature max. 200 F max. 212 F 120-195 F max. 210 F max. 195 F 120-180 F 120-180 F max. 200 F 125 psi Maximum Working Pressure 150 psi 150 psi 145 psi 150 psi 145 psi 125 psi 150 psi 200 psi 5 F Approach Temperature (outlet maximum within F of inlet HW supply) 5 F not stated not stated not stated not stated 10 F 10 F 27 F Yes Lead Free* No Yes Yes No No No Yes Yes Lockable Temperature Setting Yes Yes Yes Yes Yes Yes Yes No Standard Unions Order Separate Yes Yes Order Separate No Yes Yes Yes Standard Checks Order Separate Yes Yes Order Separate No Yes Yes No Standard Filters No No Yes Order Separate No Yes No Yes - MIPS Connection Type Threaded Yes Yes Yes Yes* Yes* Yes Yes Yes Yes Yes Yes Sweat Yes Yes Yes Yes Yes Yes Yes No Yes Yes No CPVC Yes Yes Yes Yes* Yes* Yes Yes No No No No PEX Yes Yes Yes Yes Yes Yes Yes No Yes No No Quick Connect No No No Yes* Yes* Yes Yes No No No No Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant *only available in 1/2 & 3/4 22-Sep-10 *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. 12 13
For Technical Assistance Call Your Authorized Watts Representative. Telephone E-mail Headquarters: Watts Regulator Company 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 watts@wattswater.com North East Mid Atlantic Edwards, Platt & Deely, Inc. 277 Royal Ave., Hawthorne, NJ 07506 973 427-2898 p044@watts.com Edwards, Platt & Deely, Inc. 368 Wyandanch Ave., North Babylon, NY 11703 631 253-0600 p073@watts.com Vernon Bitzer Associates, Inc. 980 Thomas Drive, Warminster, PA 18974 215 443-7500 P009@watts.com W. P. Haney Company, Inc. 51 Norfolk Ave., South Easton, MA 02375 508 238-2030 p088@watts.com Disney McLane & Associates 428 McGregor Ave., Cincinnati, OH 45206 800 542-1682 p017@watts.com J. B. O Connor Company, Inc. P.O. Box 12927, Pittsburgh, PA 15241 724 745-5300 p047@watts.com RMI 2533 Mechanicsville Tpk., Richmond, VA 23223 804 643-7355 rmi@ricmrk.com The Joyce Agency, Inc. 8442 Alban Rd., Springfield, VA 22150 703 866-3111 p069@watts.com WMS Sales, Inc. (Main office) 9580 County Rd., Clarence Center, NY 14032 716 741-9575 p091@watts.com South East Billingsley & Associates, Inc. 2728 Crestview Ave., Kenner, LA 70062-4829 504 602-8100 p013@watts.com Billingsley & Associates, Inc. 478 Cheyenne Lane, Madison, MS 39110 601 856-7565 ckenny@billingsley.com Francisco J. Ortiz & Co., Inc. Charlyn Industrial Pk., Road 190 KM1.9 - Lot #8, Carolina, Puerto Rico 00983 787 769-0085 p029@watts.com Mid-America Marketing, Inc. 203 Industrial Drive, Birmingham, AL 35211 205 879-3469 p032@watts.com Mid-America Marketing, Inc. 2611 Grandview Avenue, Nashville, TN 37211 615 259-9944 john@midamericamktg.com Mid-America Marketing, Inc. 5466 Old Hwy. 78, Memphis, TN 38118 901 795-0045 sales@midamericamktg.com Smith & Stevenson Co., Inc. 4935 Chastain Ave., Charlotte, NC 28217 704 525-3388 p003@watts.com Harry Warren, Inc. 1400 North Orange Blossom Trail, Orlando, FL 32804 407 841-9237 p071@watts.com Watts Georgia 2861-B Bankers Industrial Drive, Atlanta, GA 30360 770 209-3310 p059@watts.com North Central Canada Western South Central Dave Watson Associates 1325 West Beecher, Adrian, MI 49221 517 263-8988 p085@watts.com Mid-Continent Marketing Services Ltd. 1275 Lakeside Drive, Romeoville, IL 60446 630 953-1211 p072@watts.com Soderholm & Associates, Inc. 7150 143rd Ave. N.W., Anoka, MN 55303 763 427-9635 company@soderholmrep.com Stickler & Associates 203 S. Curtis Road, Milwaukee, WI 53214 414 771-0400 sales@sticklerassociates.com Hugh M. Cunningham, Inc. 13755 Benchmark, Dallas, TX 75234 972 888-3808 p031@watts.com Sandia Group, Inc. 3167 San Mateo #308, Albuquerque, NM 87110 800 339-0191 p031@watts.com Mack McClain & Associates, Inc. 4407 Meramec Bottom, Suite G, St. Louis, MO 63129 314 894-8188 p045 @watts.com Mack McClain & Associates, Inc. 1450 NE 69th Place, Ste. 56 Ankeny, IA 50021 515 288-0184 p049@watts.com Mack McClain & Associates, Inc. 15090 West 116th St., Olathe, KS 66062 913 339-6677 p083@watts.com OK! Sales, Inc. 214 NE 12th. St., Ste A, Moore, OK 73160 405 794-5200 oksales@coxinet.net Delco Sales, Inc. 1930 Raymer Ave., Fullerton, CA 92833 714 888-2444 sales@delcosales.com Delco Sales, Inc. 111 Sand Island Access Rd., Unit I-4, Honolulu, HI 96819 808 842-7900 p021@watts.com Fanning & Associates, Inc. 6765 Franklin St., Denver, CO 80229-7111 303 289-4191 sales@fanningandassociates.com Hollabaugh Brothers & Associates 6915 South 194th St., Kent, WA 98032 253 867-5040 p001@watts.com Hollabaugh Brothers & Associates 3028 S.E. 17th Ave., Portland, OR 97202 503 238-0313 p006@watts.com P I R Sales, Inc. 3050 North San Marcos Place, Chandler, AZ 85225 480 892-6000 sales@pirsales.com REPCOR 2455 Mercantile Drive, Ste.100, Rancho Cordova, CA 95742 916 386-2233 sales@repcor1.com R. E. Fitzpatrick Sales, Inc. 4109 West Nike Dr. (8250 South), West Jordan, UT 84088 801 282-0700 p007@watts.com Watts Water Technologies (Canada) Inc. 5435 North Service Road, Burlington, Ontario L7L 5H7 905 332-4090 info@wattscanada.ca Con-Cur West Marketing, Inc. 71B Clipper Street, Coquitlam, British Columbia V3K 6X2 604 540-5088 dconte@concurwest.com D.C. Sales Ltd. #13-6130 4th St. S.E., Calgary, Alberta T2H 2B6 403 253-6808 barry.graham@dcsalesltd.com D.C. Sales Ltd. 16726 111 Ave, Edmonton, Alberta T5M 2S6 780 496-9495 barry.graham@dcsalesltd.com GTA Sales Team. Greater Toronto Area 888 208-8927 gtasales@wattscanada.ca Hydro-Mechanical Sales, Ltd. 3700 Joseph Howe Drive, Suite 1, Halifax, Nova Scotia B3L 4H7 902 443-2274 jeff@hydromechanical.ca Hydro-Mechanical Sales, Ltd. P.O. Box 1445 (Mailing), 297 Collishaw St., Suite 7 (shipping) Moncton, New Brunswick E1C 9R2 506 859-1107 mark@hyromechnical.ca J.D.S. Sales Ltd. 4 Lancaster Street, St. John s, Newfoundland A1A 5P7 709 579-5771 jds@nf.sympatico.ca Les Ent. Roland Lajoie 6221 Marivaux, St-Leonard, QC H1P 3H6 514 328-6645 info@ent-lajoie.com Les Ent. Roland Lajoie 23 du Buisson, Pont Rouge, QC G3H 1X9 418 873-2500 strudel@ent-lajoie.com Mar-Win Agencies, Ltd. 1333 Clifton St., Winnipeg, Manitoba R3E 2V1 204 775-8194 marwin@mts.net Northern Mechanical Sales P.O. Box 280 (mailing) 163 Pine St. (shipping), Garson, Ontario P3L 1S6 705 693-2715 normec@sympatico.ca Palser Enterprises, Ltd. P.O. Box 28136 (mailing), 1885 Blue Heron Dr., #4, London, Ontario N6H 5L9 519 471-9382 sales@palserent.com RAM Mechanical Marketing Inc. 905 Winnipeg Street, Regina, Saskatchewan S4R 1J1 306 525-1986 ram@accesscomm.ca RAM Mechanical Marketing Inc. 510 Ave M South, Saskatoon, Saskatchewan S7M 2K9 306 244-6622 info@rammarketing.ca Walmar Mechanical Sales 24 Gurdwara Rd., Nepean, Ontario K2E 8B5 613 225-9774 chrisbrown@walmar.net 1116 Telephone E-mail EXPORT Hdqtrs.: Watts Regulator Co. 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 watts@wattswater.com A Watts Water Technologies Company F-ProdSelectionGuide 1038 USA: No. Andover, MA Tel. (978) 688-1811 Fax: (978) 794-1848 www.watts.com Canada: Burlington, ON Tel. (905) 332-4090 Fax: (905) 332-7068 www.wattscanada.ca 2011 Watts