Intelligent Cable Management Systems



Similar documents
TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

Building Telecommunications Infrastructure Requirements

Terminating 25-Pair Cable and 4-Pair Cross Connects

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Structured and Point to Point Network Cabling for Industrial Automation

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Minimum Standards for Data/Voice Infrastructure in New Building Construction

800 Communications Circuits

SECTION O FIBER OPTICS

Sewing Methods Chicago Style Stitch

UT Southwestern Medical Center Information Resources Cable Installation Standard

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TCTC Cabling Specifications

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Standards and Guidelines for Telecommunications Wiring Design and Installation Montana State University-Bozeman

Data Center Cabling Design Trends

Cable management for rack-mounted systems

Specifications for Communication Cabling Distribution Systems

Cable Installation Project

SBC Companies Fiber Distribution Frame Interbay Management Panel Cross-Connect Procedures

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

Network Cabling Guide

Installation Manual For Support Call or

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

SECTION TELECOMMUNICATION ROOMS

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Purpose of the ANSI/TIA/EIA-569-A Standard

1 Campus Cabling Systems Introduction

DESIGN GUIDELINES. Local Area Network

Designing A Communications Cabling System for the Colocation Data Center Larry Smith President, ABR Consulting Group, Inc.

InstaPATCH Cu Cabling Solutions for Data Centers

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

SECTION COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

B. PART 1 - GENERAL of SECTION BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

Developing the Green Data Center

Building a Tier 4 Data Center on a Tier 1 Budget

Solar Panel Installations

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

Request for Proposal (RFP) IP Cameras/Door Access Control

Specifying an IT Cabling System

4 Installation Requirements

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE

ADC Structured Cabling Solutions

Telecommunications Infrastructure Standard for Data Centers Tutorial

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Division 27 Master Specification for

What is a Datacenter?

LOS ANGELES CITY COLLEGE Technology Design Standards

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

CABLE SUPPORT SYSTEMS

Coordinate size and location of telecommunications rooms with the architect to be in compliance with this document and NEC Article 800.

SECTION J -- CABLING

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

Security & Surveillance Cabling Systems

March Commissioning of Communications. See Appendix E

AMP NETCONNECT Data Center Cabling Solutions

Secure your IT equipment with confidence... secure with NetClosure

Healthcare. Carol Everett Oliver, RCDD, ESS. Berk-Tek, a Nexans Company

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

Best Practices Guide: High Density Cable Management Solutions

ATT-TP Internet Services Cabinet Supported Cable Rack Requirements

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

Organizing and Managing Equipment Rooms

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

Cabinets 101: Configuring A Network Or Server Cabinet

BICSI NxtGEN & Global Data Center Standards Update

BIX Termination Blocks

Application Note Optical Fiber Cable

TELECOMMUNICATIONS NETWORK STANDARDS AND GUIDELINES FOR THE NEW ADMINISTRATION BULDING

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec )

Installing Commercial Building Telecommunications Cabling

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

Transcription:

Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton

Why Cable Management Matters Performance Cooling and air-handling Maintenance

ANSI/TIA 569* Telecommunication Spaces Entrance Facilities (EF) Equipment Rooms (ER) Telecommunications Rooms (TR) Telecommunication Enclosures (TE) Telecommunications Pathways Ceiling spaces Under Floor Furniture pathways

Pathways and Cable Supports Attached to support weight and pulling Installed with clear vertical space above the ceiling tiles and t-bars. Should not rest on panels, wires, power or light fixtures Use properly sizes for cable Design in room for growth

J Hook Cable Support Spacing Intervals for effective support and distribution. Cable Sag between 4 and 12 in. Use independent support rods or wire to mount For large bundles split the bundle or use a cable tray.

Cable Trays and Ladder Racks Design for 25% fill ratio Maximum of 50% fill and up to 6 in inside depth. Utilize Retaining post to contain cables Protect the cable from treaded rod supports

Conduit Guidelines Do Not exceed 100ft between pull points Flexible Metal Conduit is not recommended Maximum Fill Ratio: Maximum Fill Ratio Number of Cables Maximum Fill (%) 1 53% 2 31% 3* 40%

Optical Fiber Raceway Use innerduct or raceway to ensure protection Must be free of sharp bends and turns The Raceway must have the proper fire rating

Two Categories Mechanical Non-Mechanical Putties Caulks Fire Stopping Pre-Manufactured Pillow

Cable Handling Physical damage to the cable will cause degradation in performance Condition the cable to prevent cracking No kink, twist, snag or not while pulling.

Cable Pulling Watch edges of conduit, tray and sleeves Steady as it goes don t be a jerk Maximum Pulling Tension: Cable Type Maximum Pull Strength 4 Pair 100Ω U/UTP 25 lbf (111 N) Multipair 100Ω U/UTP * 4 Pair 100Ω shielded * Premise Distribution Fiber 50 lbf (222 N) OSP Optical Fiber 600 lbf (2.65 kn)* * Check manufacturer s specifications for maximum pulling tension

Cable Runs

Bend Radius Allowable varies with cable type and OD Cable Type Bend Radius No-Load Load 4 Pair 100Ω U/UTP 4 - - Multipair i 100Ω U/UTP 10 - - 4 Pair 100Ω shielded 8 - - Premise Distribution Fiber (1-4 strands) - 1 2 Premise Distribution ib ti Fiber (5+ strands) - 10 15 OSP Optical Fiber - 10 20 Note: In all cases follow manufactures recommended instructions. Cat 5e Cat 6 Cat 6A

Micro- and Macro-Bending Violating the bend radius causes Macro- Excessive pull Tension or tight tie wraps cause Micro- Both cause unwanted light loss

Cable Bundles Cable stress should be minimized Do not over cinch bundles Recommend Velcro style wraps Stacking bundles can cause crush Separate Cu and Fiber

Horizontal Cable Managers Minimize damage Facilitate moves, adds and changes Improve performance Angled Patch Panels address some need Rear Managers are also needed

Vertical Cable Managers Must be appropriately p sized Symmetrical Distribution Waterfalls

Cable Slack Slack loops or service loops help to accommodate future Recommended amount of cable slack: TR or TE is 10ft (3m) Ceiling about the TO is 3.28 ft (1 m) The recommended slack after termination 1ft(3 (.3m)for balanced dtwisted t pair 3.28 ft (1 m) for optical fiber

Important Considerations Avoid over-bundling the cables or placing multiple bundles on top of each other Avoid blocking access to other equipment such as power strip.

Important Considerations Keep all cable runs under 90 percent of the maximum distance supported.. For backbone and horizontal runs, install additional cables as spares.

Important Considerations Don t stress the cable by: apply additional twist Pulling or stretching beyond load rating Bending beyond the bend radius Creating tension in suspended runs Stapling or applying ppy pressure with cable ties Avoid pipes and holes limiting future runs

Best Practices Label cables with their destination at every termination point Test every cable as it is installed and terminated. Do not route cables in the way of fans or air flow

Best Practices cont. Allocate a port in the patch panel for each horizontal run Include sufficient vertical and horizontal managers in the design. Use angled patch panels in high-density areas.

Unique Solutions Using fiber cable assemblies that have a single connector at one end and multiple duplex break out at the other end. Corner bend radius Wire tray waterfall

Summary Cabling represents <10% of the overall data center investment Outlives most of the network components Most difficult to replace Requires versatility for current and future needs Since each environment is different, there is no single solution that will meet all your cable management needs.

Thank You