EFFECT OF CERTAIN LIQUID FILTER ADDITIVES ON MENTHOL DELIVERY



Similar documents
SUCRALOSE. White to off-white, practically odourless crystalline powder

Tar Yield Nicotine CO Yield

How To Develop A Recipe Card

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Benzo[a]pyrene Method Development

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Separation of Amino Acids by Paper Chromatography

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Purification of reaction mixtures using flash chromatography.

CORESTA RECOMMENDED METHOD Nº 80

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

RHOPLEX SG-10M 100% Acrylic Emulsion For Interior/Exterior Semigloss Latex Paints

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

ß-CYCLODEXTRIN SYNONYMS

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

ETHYL LAUROYL ARGINATE

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Diffusion and Fluid Flow

Fractional Distillation and Gas Chromatography

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Pesticide Analysis by Mass Spectrometry

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Anion chromatography using on-line recycled eluents

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA.

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Black epoxy paste adhesive system

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

Thermal Conductivity Detector

Background Information

Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006)

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

A Comprehensive Laboratory Test to Analyze the Compatability of Leading Cleaners and Sanitizers on Today's Industrial Refrigeration Evaporator Coils.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Marmara Üniversitesi Fen-Edebiyat Fakültesi Kimya Bölümü / Biyokimya Anabilim Dalı PURIFICATION AND CHARACTERIZATION OF PROTEINS

Carbohydrate Analysis: Column Chemistries and Detection

Gas Chromatograph GC Consumables. p/n:

The Use of Hydrogen Carrier Gas for GC/MS

Chapter 28: High-Performance Liquid Chromatography (HPLC)

RTV162. Electronic Grade Silicone Adhesive Sealant

Sterilization methods and equipment Lab 1-2

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Marko Hakovirta SVP, Innovation and R&D

WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

Discharge station for bags and big bags. MKSB

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Supporting Information

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

Analysis of Various Vitamins in Multivitamin Tablets

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

BRILLIANT TONER SERIES TONERS FOR PRINTING INKS BSTS SERIES

Permeability Study on the Coating Film Consisting of CA NF/EP and CA- 320S NF/EP

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS Description. Key Features and Benefits. Typical Physical Properties

Products & OEM Services

TCI Chiral HPLC Column

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Temperature C Cure time to reach hours LSS > 1MPa minutes

Eastman plasticizers. Bulk storage guidelines. Storage equipment. Tank components and materials. Piping. Pumps. Valves. Gaskets

Araldite GY 6010 A Medium Viscosity, Unmodified Liquid Epoxy Resin

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

CHAPTER 48 DRUG PARAPHERNALIA

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Czech J. Food Sci. Vol. 25, No. 5:

The Analytical Balance

Effect of Filler Type on the Stability of Polyethylene Oxide in a Hydrophilic Matrix Tablet

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Others ph conductivity measurement module ph and conductivity measurement in 96 deep well plates

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Invitation to Bid SCHOOL SIGN - MCE

CHROMOCTANE O N LINE ANALYZER

Aromatic plants: from extraction to analysis

Electrospray Ion Trap Mass Spectrometry. Introduction

Training Courses 2014 HPLC GC SPE

How To Test For Contamination In Large Volume Water

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Transcription:

Publication No. FTR-40 EFFECT OF CERTAIN LIQUID FILTER ADDITIVES ON MENTHOL DELIVERY TENNESSEE EASTMAN COMPANY KINGSPORT, TENNESSEE 37662 510000385

EFFECT OF CERTAIN LIQUID FILTER ADDITIVES ON MENTHOL DELIVERY John G. Curran Research Laboratories / Tennessee Eastman Company Distributed by EASTMAN CHEMICAL PRODUCTS, INC., Kingsport, Tennessee 37662 EASTMAN CHEMICAL INTERNATIONAL A.G., Zug, Switzerland EASTMAN CHEMICAL INTER-AMERICAN LTD., Kingsport, Tennessee 37662 EASTMAN CHEMICAL INTERNATIONAL COMPANY, Kingsport, Tennessee 37662 t Publication No. FTR-40 510000386

It is well documentedl-2,3 that menthol migrates from the tobacco column of a cigarette to its filter during storage in a cigarette pack. It is logical to assume that casings might affect the affinity of tobacco for menthol and that liquid additives on a cellulose acetate filter might affect its affinity for menthol. It has been reportedl that the amount of menthol in a filter affects menthol delivery, since menthol retention by a filter decreases as the concentration of menthol in the filter increases. If the assumption is correct that liquid additives affect the affinity of a fifter for menthol, then they might also affect menthol delivery. The purpose of this work was to determine whether the addition of triacetin, triethylene glycol diacetate, glycerol, or 1,2-propanediol to cellulose acetate filters affects either the affinity of a filter for menthol or the amount of menthol delivered by a cigarette. Cigarettes All experimental mentholated filter cigarettes were constructed in our laboratory. The tobacco columns were 64 mm in length and contained approximately 2 mg of menthol. These tobacco columns were obtained from 100-mm mentholated cigarettes purchased in Kingsport, Tennessee. The filters were constructed from 3.3 den./fil, 39,000 total denier cellulose acetate tow. The liquid additives were applied to the tow, with a brush applicator. The filter and tobacco column were attached with a laboratory tipping apparatus. Storage and Testing of Cigarettes The cigarettes. were sealed in cigarette packs and stored for one, three, and six weeks. Each pack contained 16 cigarettes. Six cigarettes were used in the menthol distribution experiments. These cigarettes were separated into filter and tobacco segments before being analyzed. Ten cigarettes were used in the smoking experiments. They were smoked according to the Federal Trade Commission's specifications with a Phipps and Bird automated 1 510000387

smoking machine. The smoke from five mentholated cigaretteswas collected.on a Cambridge filter pad ; two pads were combined before being analyzed. Analysis Ethanol was used to extract menthol from the six cellulose acetate filters, the six tobacco columns, and the two Cambridge filter pads. A known weight of internal standard (pentadecane) was added to.each extract. The extracts were shaken for 2 hr before being analyzed by gas chromatography. The gas chromatographic unit was equipped with a single 3 1/2-ft x 1/8-in, stainless steel column packed with Chromsorb W (60 to 80 mesh) coated with 10% w/w Castorwax. Operating conditions were as follows : column and detector temperature 165 C ; injector temperature 250 C ; helium and hydrogen flow 30 ml/min ; air flow 360 ml/min. Migration of Menthol in a Cigarette The effect of triacetin and triethylene glycol diacetate on the affinity of a cellulose acetate filter for menthol during storage in a, cigarette pack is shown in Figure 1. The percentage of menthol on all of the filters increased with storage. Filters bonded with 8% triethylene glycol diacetate contained the highest percentage of inenthol, while filters with 0% plasticizer contained the lowest percentage of menthol. The percentage of menthol migrating from the tobacco to the filter is a measure of the affinity of the filter for menthol. The order of plasticizer affinity for menthol is 8% triethylene glycol diacetate > 8% triacetin > 5% triethylene glycol diacetate>5% triacetin >0% plasticizer. These results show that cellulose acetate filters without plasticizer have a lower affinity for menthol than filters bonded with either triacetin or triethylene glycol diacetate ; that filters bonded with triacetin have a lower affinity for menthol than filters bonded with triethylene glycol diacetate ; that the affinity of filters for menthol increases as plasticizer concentration increases. The migration rate of menthol from the tobacco to the filter also increases as plasticizer concentration i ncreases. it 2 510000388

FIGURE 1 EFFECT OF PLASTICIZER ON MENTHOL MIGRATION MENTHOL ON FILTER, % 36 r- 30 24 8%TRIETHYLENE GLYCOL DIACETATE 8%TRIACETIN 5% TRIETHYLENE GLYCOL DIACETATE 5 k TRIACETIN 18 12 6 0% PLASTICIZER I I I I 1 1 1 2 3 4 5 6 TIME, WK The effect of glycerol and 1,2-propanediol on the affinity of a triacetin (8%) bonded cellulose acetate filter for menthol is shown in Figure 2. The percentage of menthol on all of the filters increased with storage. Filters treated with 1,2-propanediol contained a higher percentage of menthol than filters with either glycerol of 0% additive. There was no difference in the percentage of menthol on filters treated with 6and 10% 1,2-propanediol. This was also true for filters treated with 6 and 10% glycerol. These results FIGURE 2 show that treating triacetin-bonded EFFECT OF GLYCEROL AND 1,2-PROPANEDIOL cellulose acetate filters with glycerol ON MENTHOL MIGRATION MENTHOL ON FILTER,% does not alter their affinity for 48 menthol ; that treating the cellulose acetate filters with 1,2-propanediol increases their affinity for menthol ; that the affinity of filters treated 24 ~ with glycerol or 1,2-propanediol 16 remained constant as the additive concentration increased from 6 to 1nN I. 40 [ / 6& iai 1,2-PROPANEDIOL 32r / G 0%ADDITIVE 6& i0% GLYCEROL 8 I I I 2 3 4 TIME, WK ALL FILTERS CONTAINED w, 8%TRIACETIN 1-6 I I 0 5 6 O O~..~ ti.d W ~A ' W 3 510000389

Menthol Delivery The effect of triacetin and triethylene glycol diacetate on menthol delivery is shown in Table 1. These deliveries fluctuated with cigarette age. The average menthol deliveries are statistically different. As plasticizer concentration increased, menthol delivery decreased. The largest delivery was obtained from a cigarette with a filter bonded with 5% triacetin and the smallest delivery was obtained from a cigarette with a filter bonded with 8% triethylene glycol diacetate. Thus, both the type and amount of plasticizer significantly altered menthol delivery. TABLE 1 EFFECT OF PLASTICIZER ON MENTHOL DELIVERY. Menthol delivered, mg Plasticizer 1 wk 3 wk 6 wk X Control (0%) 0.35 0.34 0.32 0.34 Triacetin (5%) 0.37 0.41 0.38 0.39 (8%) 0.34 0.37 0.36 0.36 Triethylene (5%) 0.34 0.35 0.31 0.33 Glycol (8%) 0.32 0.32 0.27 0.30 Diacetate There was no correlation between the menthol delivery of these cigarettes and the affinity of their filters for menthol. Of the five filters, the one bonded with 8% triacetin had the second highest affinity for menthol, yet cigarettes with this filter had the second highest menthol delivery ; nonbonded filters had the lowest affinity for menthol. However, two other cigarettes, whose filters had a greater affinity for menthol, delivered more menthol. One explanation for these results is that cigarette smoke changes the affinity of a filter for menthol. The effect of glycerol and 1,2-propanediol on menthol delivery is shown in Table 2. The menthol delivery decreased with cigarette age, while the delivery of the control cigarette fluctuated with age. Therefore, the addition of glycerol and 1,2-propanediol to a filter reduces menthol delivery. t 4 510000390

TABLE 2 EFFECT OF GLYCEROL AND 1,2-PROPANEDIOL ON MENTHOL DELIVERY Menthol delivered, mg Addi t ive 1 wk 3 wk 6 wk X Control (0%) 0.34 0.37 0.36 0.36 l (6%) 0.32 0.31 0.27 0.30 Gl ycero (10%) 0.32 0.30 0.27 0.30 l (6%) 0.31 0.29 0.27 0.29 1, 2-P ropanedi o (10%) 0.31 0.27 0.22 0.27 AII filters contained 8% triacetin. There was no correlation between the menthol delivery of these cigarettes and the filter's affinity for menthol. The affinity of a triacetin (8%) bonded cellulose acetate filter was not altered by the addition of glycerol, yet there was a 15% difference in the menthol.delivery of these two filter cigarettes. In conclusion, triacetin, triethylene glycol diacetate, and 1,2-propanediol affect the affinity of a cellulose acetate filter for menthol. The affinity of a cellulose acetate filter for menthol changes as cigarette smoke is presented to it. Glycerol and the above compounds also affect the amount of menthol delivered. Both type and concentration of plasticizer affect menthol del ivery. 1. M. Brozinski, U. Dolberg, and G. Lipp, Beitr. Tabakforsch., 6 (3), 124-130 (1972). 2. J. G. Curran, Tob. Scr., 16, 40-42 (1972). 3. T. F. Riehl, L. L. Shockley, and M. L. Reynolds, Tob. Sci., 17, 10-11 (1973). ECP 2944 Printed tn U.S.A. 510000391

Eastman Kodak Company and its marketing affiliates disclaim responsibility for results of use of this information, which is furnished without charge, or of any product, method, or apparatus mentioned herein. It is the user's responsibility to make and be guided by his own tests in determining suitability of any such product, method, or apparatus for his purpose. No statement or suggestion herein is to be considered a recommendation or inducement of any use, manufacture, or sale.that may infringe ' any patents now or hereafter 'in existence. 510000392