Scheme 3: Rehabilitation of Heritage Building and Redevelopment



Similar documents
BROWNSVILLE STRUCTURES STUDY. July Prepared by. LDA ARCHITECTS 33 Terminal Way, Suite 317 Pittsburgh, Pennsylvania

Presentation: Proposed Plan Amendments

28.0 Development Permit Area #2 (Neighbourhood District)

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines

City of Surrey PLANNING & DEVELOPMENT REPORT File:

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Facility Assessment for East Main Street, Huntley, IL

Section 13 Urban Residential Zones

Introduction. Welcome London Road, Mitcham

Retail or Wholesale In conformity with the provisions of sub-section Art Gallery, Museum or Library In conformity with the

Sergison Bates architects. 90 Masterplan for landscape and urban housing, Newham, London

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Design and Access Statement Earls Court Road London SW5 9RH

Downtown Core Sub-district

Kingston Rd Removal of a Holding Provision (H) Application Final Report

Churches and Schools Development Standards

Financial Analysis for the Ambleside Centre Zoning Districts

d. Building permits may only be approved if consistent with the approved development plan and land division for all units with common walls.

BUILDING PERMIT SPECIFICATIONS

Transfer of 497 Richmond Street West to Build Toronto

Revere Beach Transit-Oriented Development Parcels Revere, Massachusetts. Design and Development Guidelines. Part Two.

Oliver House City Road, EC1. Design & Access Statement Addendum Oliver House

Friends Seminary Presentation to NYC Landmarks Preservation Commission 21 April 2015 Kliment Halsband Architects


VISION, DESIGN PRINCIPLES & OVERALL PLANNING STRATEGY

WELLINGTON STREET WEST COMMUNITY DESIGN PLAN

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

STAFF REPORT. December 20, North District Community Council. Director of Community Planning - North

A site plan or floor plan clearly identifying the location(s) of all new replacement window(s)

redland house, bristol - public consultation exhibition

HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. Application Guidelines

TULSA PRESERVATION COMMISSION COA SUBCOMMITTEE - STAFF REPORT

WELCOME WELCOME TO THE PUBLIC EXHIBITION FOR THE ILONA ROSE HOUSE REDEVELOPMENT. ILONA ROSE HOUSE

CITY COUNCIL PACKET MEMORANDUM

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES


TULSA PRESERVATION COMMISSION

KINGSTON TOWN PLANNING SUB-COMMITTEE 23 MARCH YELLOW BOX STORAGE , LONDON ROAD AND 50, GORDON ROAD, Application Number: 05/12156

12.9 PART CD-9 ZONE, DOCKSIDE DISTRICT

TYPES OF PROPERTIES ARE INCLUDED WITHIN THE T3 TRANSECT DESIGNATION?

The Zig Zag Building Victoria Street, London, SW1

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada

Draft Goals and Objectives Wadena Comprehensive Plan City of Wadena, Minnesota. Land Use Goals:

05 AREA/SITE SPECIFIC GUIDELINES

Assisted Living & Memory Care

Architectural Design Standards Example Guide DESIGN STANDARDS EXAMPLE GUIDE

Atkins Park Historic District Regulations (Chapter 20O) The intent of the regulations for the Atkins Park Historic District is as follows:

Former Gala Bingo Kingston TOWNSCAPE STUDY AND SUPPORTING DESIGN + ACCESS STATEMENT January 2014

CHAPTER 5 - "R1" SINGLE-FAMILY RESIDENTIAL DISTRICT

Saint Cloud Business Center

FOR SALE. The Friedman Building th Avenue South, Seattle Nicholas T. Gill Allan Friedman

Sisal Composite Ltd. Apparel 4 Ltd. JM Knit Ltd. Natun Para, Hemayetpur, Savar, Dhaka-1340 ( N, E)

Access onto roof from Center Block

23 Glen Watford Drive - Zoning Amendment Application - Preliminary Report

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

HISTORIC PRESERVATION REVIEW BOARD STAFF REPORT AND RECOMMENDATION st Street, NW Thaddeus Stevens School

City of Fort Lauderdale Historic Preservation Design Guidelines

SECTION 6 COMMERCIAL ZONES

423 NORTH HOWARD ST. VISUAL STRUCTURAL ASSESSMENT

The Role of Land Use and Transportation in Building Successful Sustainable Cities City of Vancouver

UNIQUE LIVE/WORK LOFT

Welcome & background.

AMENDED OUTLINE DEVELOPMENT PLAN, VILLAGE DOCKLANDS PRECINCT, 2-46 BATMANS HILL DRIVE, DOCKLANDS

How To Build A Luxury Apartment Complex In London

Glossop Design & Place Making Strategy

Los Angeles Union Station, CA Sustainable Neighborhood Assessment. April 22-23, 2014

Appendix "B" - Development Checklist

Historic Renovation. passionate principals + committed professionals + unparalleled service

R 1 Design Review Application

2.50 Retirement villages - section 32 evaluation for the Proposed Auckland Unitary Plan

Residential Decks. Planning and Development Services Department

K M D Hire Services, LONDON ROAD, NANTWICH, CW5 6LU

Architectural Control Guidelines

29 Broadway- 14 th Fl Tel: New York NY Fax: Due Diligence Report. New York, New York

Physician s Residence. Historic Structure Report IV. Building Treatment Approach

Edward R. Sajecki Commissioner of Planning and Building

Slavic Village Building Condition Review

CHAPTER 1 INTRODUCTION

TOWN BOARD OF THE TOWN OF NORTH SALEM WESTCHESTER COUNTY, NEW YORK LOCAL LAW # OF THE YEAR 2012

Supports Item No. 1 CS&B Committee Agenda July 26, 2007 CITY OF VANCOUVER

DESIGN GUIDELINES FOR UTILITY METERS D.C. HISTORIC PRESERVATION REVIEW BOARD

Sample Drawing Package for One and Two Family Dwelling Applications

TOWN OF CARY CONDITIONAL USE ZONING PERMIT. 412 Rutherglen Cary, NC Rutherglen Cary, NC

Palmer Street/Great Barr Street, (former MacDermid warehouse), Digbeth, Birmingham, B9 4AY

HurlinghamRetailPark. Aerial view of site. Welcome to our exhibition of proposals for the redevelopment of the Hurlingham Retail Park.

D3 April 8, 2015 Public Hearing

Ward: Purley DELEGATED BUSINESS MEETING Lead Officer: Head of Planning Control week of 23/03/2009

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

RESIDENTIAL WOOD DECKS

Twickenham AAP Opportunity sites December Twickenham Area Action Plan. Opportunity Sites

ARTICLE VIII SECTION 8.1 O-I OFFICE INSTITUTIONAL DISTRICT

7.0 GOALS, OBJECTIVES & POLICIES

3.3 PROPOSED VARIATIONS TO GUILDFORD DESIGN GUIDELINES AND DETAILED AREA PLAN FOR SINGLE DWELLING - LOT 203 (NO.4) WELLMAN STREET, GUILDFORD

Transcription:

Scheme 3: Rehabilitation of Heritage Building and Redevelopment 135 Keefer Street Constructed in 1910 for the Vancouver Gas Company, the building and surrounding site was used primarily by blacksmiths servicing the teamsters of the transportation industry until 1949. This site like Yaletown, serviced the adjacent industrial land and rail yards surrounding False Creek. Typical Floor Plan of the Building Unit Tally and Area Totals Cross Section of the Building Scheme 3: Joe Wai Architect Inc.

Scheme 4: Conversion of Commercial Building Birmingham & Wood Architects 211 Main Street Golden Crown Centre The Golden Crown Centre is a mixed use building currently comprised of retail, office and parking uses. At the ground level are several retail spaces facing Main Street and one facing East Georgia Street. A two-way parking entry/exit also faces East Georgia Street. Approximately 40% of the second, third and fourth levels were designed for office/business use. The building site measures 107 feet along Main Street and 120 feet along East Georgia Street permits for the building were applied for in 1986. The building was probably completed in 1987 or 1988. It was one of a number of buildings of similar size and smaller building in the same period. The large proportion of the building dedicated to parking is indicative of an attitude prevailing at that time that it was partly a lack of parking in Chinatown that make the area increasingly uncompetitive with new shopping opportunities being developed primarily in Richmond. The structure is a cast-in-place concrete slab, slab band and column structure. The concrete is faced with red brick on the Main Street, East Georgia Street and land facades. The vertical column/slab grid is infilled with: glazing at the retail and office spaces; concrete masonry units at the party wall; and is open at the parking levels. Scheme 4: Birmingham & Wood Architects

Background The upper storeys in many Chinatown buildings are vacant and/or underutilized. In addition, a number of storefronts are also vacant. Through the community development process that shaped the Chinatown Vision, the idea of residential intensification was identified as a goal. Having more residents in the area would help reoccupy upper storeys plus have the added benefit of increasing business opportunities in the area particularly for the provision of services for local residents. Objective 1) Identify typical characteristics of Chinatown buildings and its urban development pattern, and 2) To determine opportunities and challenges in accommodating market housing. Map of Sites Site #1: Rehabilitation of Heritage Buildings(s) Consultant: Acton Ostry Architects Inc. HA -1 heritage building(s) - 2 schemes * Wong Building (121 E Pender) - 1921 * Lee Building (127 E Pender) - updated 1973 * Lung Kong Kung Shaw Society (135 E Pender) * Mah Society (137 E Pender) - 1915 HASTINGS ST. #2 #1 TAY L OR ST. CARRALL ST. COLUMBIA ST. #3 MAIN ST. PENDER ST. KEEFER ST. G ORE ST. Site #2: New Construction and Rehabilitation of Heritage Building Consultant: Busby & Associates HA -1 heritage building plus vacant site * Cheung Wing Yeong Tong Society (79-83 E Pender) - 1926 * Vacant Site (75 E Pender) - 2001 #4 GEORGIA ST. Site #3: Rehabilitation of Heritage Building and Redevelopment Consultant: Joe Wai Architect Inc. HA -1A character building plus vacant site * Character building (135 Keefer) - 1910 * Vacant Site (137 Keefer) * Brick Building (139 Keefer) - 1980s UNION ST. N Site #4: Conversion of Commercial Building Consultant: Birmingham & Wood Architects HA -1A 1980s commercial/parking building * Gordon Crown Centre on Main Street (211 Georgia) - 1987 Study Background

Key Findings of the Study Small Lot Developments Are Economically Viable Recommendations for the By-laws: 25 Lot 4-storey Wood frame 50 Lot 4-storey Wood frame 25 Lot 8-storey 50 Lot 8-storey 150 Lot Multi-storey Including land value (For both property owners and developers) Strata Sale Strata Sale Excluding land value (For existing property owners) Parking provided on-site Parking provided on-site Parking provided on-site Viable Marginally Viable Not Viable (1) Vancouver Zoning and Development By-law & Associated Guidelines Regulations for maximum heights of buildings for residential developments to be considered for relaxation for certain sites and projects where retention of existing buildings is desired and where the additional height and mass is not visible from the street and there are no negative impacts on views and shadow. Rear yard setbacks for residential uses and widths and height/width rations of courtyards to be relaxed to encourage the development of livable urban housing with a focus on delivering light and ventilation from interior courtyard as opposed to the lane. (2) Vancouver Parking By-law The existing parking and loading requirements for buildings on sites with width of 50 feet or less must have provision for relaxation to encourage finer grain development and retention of existing historic building on typical Chinatown sites. The degree of difficulty and complexity to provide underground parking on these sites is prohibitive to development of smaller properties. Unless the new construction maintains the physical and social character of Chinatown, the whole effort at reconstruction could be more damaging than beneficial to this historic resource. - Daniel Solomon Unless there is wholesale aggregation, it is not feasible to provide retail frontage and a parking space for every unit, even with reduced density goals. - Daniel Solomon Requirements for loading should have same provision for relaxations for the same reasons as parking. (3) Vancouver Building By-law A recurring item requiring relaxation for renovation of existing buildings will be the rise, run and landings of existing exit stairs. Many of these noodle stair are integral to the historic character and use of the buildings in Chinatown and should have provision for relaxations for retention. Impact of Land Aggregation on Chinatown s Fine-Grain Development Pattern 200 Block Union Street 100 Block East Pender Street Key Findings of the Study

Scheme 1: Rehabilitation of Heritage Buildings Wong Building - 121 East Pender Street The original building was constructed in 1910. During the boom years of the early 1920 s, an additional storey was added, which by that time, conformed to the established Chinatown Style of the area. The fourth floor addition by J.A. Radford included family association meeting rooms and recessed balconies, typical of the area at that time. Typical of many buildings in Chinatown, the existing building occupying approximately half of the site depth, is retained in this study. The existing single storey retail/storage area at the rear of the site is replaced by a new structure which could range between six and eight storeys in height. The new structure is built up to the rear property line at the ground floor level with a 5 setback and 23 wide courtyard is located between the existing and proposed new buildings. Cross Section of the Wong Building Typical Building Floor Plan Mah Society Building - 137 East Pender The original building was constructed in 1913. An additional storey was constructed in 1921 for the Mah Gim Do Hung Society. The assembly hall on the added top floor continues to be used by the Mah Society. The hotel use is introduced as a reference to the historical use of the building. Option A Typical Floor Plan Option B Typical Floor Plan Cross Section of the Mah Building Scheme 1: Acton Ostry Architects Inc.