Simultaneous data fitting in ARXPS



Similar documents
Dependence of the thickness and composition of the HfO 2 /Si interface layer on annealing

The interaction of Cu(100)-Fe surfaces with oxygen studied with photoelectron spectroscopy. I

h e l p s y o u C O N T R O L

Physical Properties and Functionalization of Low-Dimensional Materials

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Study of Surface Reaction and Gas Phase Chemistries in High Density C 4 F 8 /O 2 /Ar and C 4 F 8 /O 2 /Ar/CH 2 F 2 Plasma for Contact Hole Etching

THERMO NORAN SYSTEM SIX ENERGY DISPERSIVE X- RAY SPECTROMETER. Insert Nickname Here. Operating Instructions

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Secondary Ion Mass Spectrometry

X-ray photoelectron. Ba 0.5 Sr 0.5 Co 0.8 Fe 0.2 O 3 δ and La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 δ before and after thermal treatment and permeation test

Preface Light Microscopy X-ray Diffraction Methods

Supporting information

Spectroscopic Ellipsometry:

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Supporting Information

Implementation Of High-k/Metal Gates In High-Volume Manufacturing

Coating Technology: Evaporation Vs Sputtering

STRUCTURAL STUDIES OF MULTIFERROIC THIN FILMS

2. Deposition process

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Surface Characterization - Marie-Geneviève Barthés-Labrousse

Vega Spans and NiOx-TX Spans

Optical Properties of Sputtered Tantalum Nitride Films Determined by Spectroscopic Ellipsometry

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Developments in Photoluminescence Characterisation for Silicon PV

Coating Thickness and Composition Analysis by Micro-EDXRF

XPS Spectra. The XPS technique is used to investigate the chemistry at the surface of a sample.

Deposition and properties of amorphous carbon phosphide films

Analyses on copper samples from Micans

Study of tungsten oxidation in O 2 /H 2 /N 2 downstream plasma

Computer simulation of coating processes with monochromatic monitoring

The study of deep-level emission center in ZnO films grown on c-al 2 O 3 substrates

X-ray thin-film measurement techniques

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Lectures about XRF (X-Ray Fluorescence)

USING OPTICAL EMISSION SPECTROSCOPY TO IMPROVE EQUIPMENT UPTIME FOR AN AL2O3 ALD PROCESS *

THE USE OF OZONATED HF SOLUTIONS FOR POLYSILICON STRIPPING

ALD Atomic Layer Deposition

Edited by. C'unter. and David S. Moore. Gauglitz. Handbook of Spectroscopy. Second, Enlarged Edition. Volume 4. WlLEY-VCH. VerlagCmbH & Co.

A Plasma Doping Process for 3D FinFET Source/ Drain Extensions

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

Lead-Free Universal Solders for Optical and MEMS Packaging

X-ray Photoelectron Spectroscopy

Introduction to X-Ray Powder Diffraction Data Analysis

Enhancement of Breakdown Strength and Energy Density in

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

3D Scanner using Line Laser. 1. Introduction. 2. Theory

Etudes in situ et ex situ de multicouches C/FePt

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING

EDXRF of Used Automotive Catalytic Converters

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

X-ray diffraction techniques for thin films

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

XCVII Congresso Nazionale

Exploring the deposition of oxides on silicon for photovoltaic cells by pulsed laser deposition

Lapping and Polishing Basics

GIANT FREQUENCY SHIFT OF INTRAMOLECULAR VIBRATION BAND IN THE RAMAN SPECTRA OF WATER ON THE SILVER SURFACE. M.E. Kompan

1 Genzyme Corp., Framingham, MA, 2 Positive Probability Ltd, Isleham, U.K.

Anomalous Hall Effect Magnetometry A Method for Studying Magnetic Processes of Thin Magnetic Films

Chapter 6 Metal Films and Filters

Advanced VLSI Design CMOS Processing Technology

Usage of Carbon Nanotubes in Scanning Probe Microscopes as Probe. Keywords: Carbon Nanotube, Scanning Probe Microscope

Functional Gradient Hardmetals: From Research To Application

Neuere Entwicklungen zur Herstellung optischer Schichten durch reaktive. Wolfgang Hentsch, Dr. Reinhard Fendler. FHR Anlagenbau GmbH

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

State of the art in reactive magnetron sputtering

for Low power Energy Harvesting Sun to fiber' Solar Devices

Realization of a UV fisheye hyperspectral camera

Thomas Grehl. Improvement in TOF-SIMS Instrumentation for Analytical Application and Fundamental Research

Chemical Sputtering. von Kohlenstoff durch Wasserstoff. W. Jacob

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Optical Properties of Thin Film Molecular Mixtures

Al 2 O 3, Its Different Molecular Structures, Atomic Layer Deposition, and Dielectrics

Surface characterization of oxygen deficient SrTiO 3

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

ESRF OPTICAL METROLOGY APPLIED TO BENDABLE OPTICAL SURFACES

Pulsed laser deposition of organic materials

Pesticide Analysis by Mass Spectrometry

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

INCAEnergy INCA. One fully integrated platform that provides many solutions for microanalysis in the electron microscope

Hydrogen Bonds in Water-Methanol Mixture

Copyright 2007 Casa Software Ltd. ToF Mass Calibration

FTIR Instrumentation

Lateral Resolution of EDX Analysis with Low Acceleration Voltage SEM

Novel inkjettable copper ink utilizing processing temperatures under 100 degrees C without the need of inert atmosphere

ING LA PALMA TECHNICAL NOTE No Investigation of Low Fringing Detectors on the ISIS Spectrograph.

16th International Toki Conference on Advanced Imaging and Plasma Diagnostics

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Chemical dry etching of silicon nitride and silicon dioxide using CF 4 /O 2 /N 2 gas mixtures

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Optical Hyperdoping: Transforming Semiconductor Band Structure for Solar Energy Harvesting

Electromagnetic Radiation (EMR) and Remote Sensing

X15TN TM. A high hardness, corrosion and fatigue resistance martensitic grade CONTINUOUS INNOVATION RESEARCH SERVICE.

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

The study of structural and optical properties of TiO 2 :Tb thin films

Transcription:

NOTE Please find the following more updated document Resolving overlapping peaks in ARXPS data: The effect of noise and fitting method. J. Muñoz-Flores, A. Herrera-Gomez, J. Electron Spectrosc. Relat. Phenom. 184 (2012) 533. at http://www.sciencedirect.com/science/article/pii/s0368204811001034 Internal Report (Created: 9/1999. Last update: 8/2008) Simultaneous data fitting in ARXPS Alberto Herrera-Gomez CINVESTAV-Unidad Queretaro. Queretaro, Qro. Mexico 76000 I. Introduction As it is reported in other studies, an appropriate analysis of Angle Resolved X-Ray Photoelectron Spectroscopy (ARXPS) data can provide very detailed information about the structure of ultra thin conformal films with abrupt interfaces. 1-6 However, the precise way to exploit this technique, as well as the actual amount of information that it can provide, has not yet reached wide consensus in the scientific community. A possible cause of this lack of consensus is that there are a number of concatenated and interdependent issues. Each one of them has to be addressed properly in order to extract the rich quantitative information that ARXPS can provide. The analysis of ultra thin films by ARXPS can be divided in the following steps: 7 High quality data acquisition. The development of better monochromatic x-ray sources have made nowadays possible to obtain high resolution data from commercial XPS equipment. Data fitting. The first part of the analysis is data fitting, which provides the take-off angular dependence of the peaks composing the spectra. The specific way to do the fitting might vary significantly from one group to another. Characterization of the instrument. The photoemission signal strength holds an important dependence on the shape and size of the x-ray and analyzer focal spots, as well as their overlap with the sample surface. To properly account for this dependence, it is usually necessary to perform numerical integration of the photoemission signal. The calculations require a thorough characterization of the geometrical parameters of the XPS tool. Some XPS equipment makers go out of their way to provide a geometry that dodges the need of the numerical integration, but in many cases it is unavoidable. This requirement is usually overlooked. 1/7

Modeling. The second part of the data analysis is the modeling of the angle dependence of the peak areas to extract the composition depth profile. This is the most controversial step in the process since the methods and assumptions employed vary wildly in the community. Failing to properly address any of these issues has as an effect that only qualitative and vague assertions could be made about the structure of the films. This Internal Report discusses the part related to XPS data fitting. It emphasizes the need of a simultaneous treatment of the spectra taken at different angles especially for those spectra where the peaks are tangled together. This is usually the case for many elements, such as oxygen and nitrogen. II. Data fitting and the conventional approach The XPS spectra of each element in a film might be composed by different peaks corresponding to different chemical environments. For example, the structure on the right in the Si 2p spectra shown in Figure 1 corresponds to silicon in the substrate, while the structure on the left to silicon forming an oxide. 3 The depth profile of each component can be, in principle, obtained from the angular dependence of the area of its corresponding peak. When the peaks are clearly separated, as in this case, the take-off angular dependence of each chemical specie can be unambiguously obtained (see insert). 1 nm HfO 2 1 nm SiO 2 Si(001) substrate Take-Off Angle 65 55 45 35 25 Binding Energy Figure 1. XPS data for Si 2p of a film described in the insert on the right. The peak at 102.8eV (silicon in SiO2) can be clearly deconvolved from the peak at 99.4eV (bulk silicon). The take-off angular dependence is very distinctive for the two peaks. However, such deconvolution is not easily done when the different chemical components are entangled together. In such cases, as the O 1s spectra shown in Figure 2, the task for a unique and meaningful deconvolution becomes difficult. 2/7

O 1s 1 nm HfO 2 75 65 55 45 35 25 1 nm SiO 2 Figure 2. Oxygen 1s data as an example of overlapping peaks composing the data. The sample is HfO 2 on top of SiO 2 on a Si(001) substrate. The lines are the fits obtained by employing the two peak (red curves) with different relative intensities for the different angles. Each peak is ultimately associated to a chemical environment. For example, the peak on the left corresponds to oxygen in SiO 2, and the left peak to oxygen in HfO 2. The key challenge is to uniquely determine the peak parameters (FWHM, position and height) of each chemical species. A possible approach, which is conventionally employed, is to incrementally obtain better fits by iterating through the following steps: The best parameters of the peaks are found for a spectrum taken at one of the angles. There is not a unique way to accomplish this, and some initial guessing is necessary. The values are then constrained in a small range and used to fit the rest of the data. By inspecting the quality of the fits, the parameters of the first file are constrained to a value that would provide a better fit for the rest of the files. The process is taken into a loop and repeated until a good fit is found for all files. When to stop this iterative process is subjective to the judgment and patience of the operator. This is why data fitting is usually described as an art and not as a science. III. Simultaneous fitting Binding Energy (ev) Most of this ambiguity disappears when all the data is fitted simultaneously. In this alternative method all the files are fitted at the same time, and the best peak parameters are found for the whole set. Although the positions and widths of the peaks are shared among the files for all the angles, the heights are allowed to vary among them. 3/7

This method takes full advantage of all the information available. It is usually the case that the shape of the spectra changes with the take off angle. For example, in Figure 1 the relative intensity of the right and left Si structures change with angle. However, the change in shape is only slightly apparent to the eye for the case of Figure 2. This change in relative strength is due to depth differences of the various chemical species of each element. This, in fact, provides fiducial enlightenment about the positions of the peaks composing the spectrum. The larger the change in the shape, the less unambiguous becomes the assessment of the peak parameters. Simultaneous data fitting takes full numerical advantage of this phenomenon. The take off angle dependence of the peaks in Figure 2 is shown in Figure 3. Both methods, the conventional and the simultaneous, were employed. The difference is appreciable. Binding Energy (ev) 532.2 532.0 531.8 531.6 531.4 531.2 30 40 50 60 Peak at 532.2eV Peak at 531.3eV simultaneous fitting individual fitting 30 40 50 60 Take-Off Angle Figure 3. Take off angle dependence of the area of the two peaks in Figure 2. This is a case where simultaneous fitting is important. The advantages of simultaneous fitting includes include: The use of all the information available in the XPS data at all angles to assess the parameters of the peaks (center and width). The assessment of the dependence of the peak areas on take off angle that can be modeled using photoemission theory, and in this way be related to depth profile. The assessment of the parameters of the peaks (center and width). It should be that this assessment is made under the set of underlying assumptions that are, without exception, made during every kind of analysis. This would include the number of peaks employed, the shape of the background, and the value of the intrinsic Lorentzian width. Stability. Simultaneous fitting allows for inclusion of small peaks without the risk of destabilizing the procedure. 8 7 Peak Area (a.u.) 6 5 4 4/7

Consistency. There is no physical reason to expect a significant variation of the peak s center or width for the different angles. It is important to stress that the choice of the fitting method, individual or simultaneous, is not important when the peaks are sufficiently far enough from each other. That is the case of the data shown in Figure 1, which corresponds to the Si 2p spectra of a 1nm film of silica on top of a silicon substrate. However, when the sample consist of a film of silicon carbide on top of a silicon substrate, the deconvolution could be more difficult. The Figure 4 shows data for this system taken at different angles. 4 Si 2p 75 65 55 45 35 25 almost no oxide Kinetic Energy (ev) Figure 4. Silicon 2p spectra for the DLC-E 15Å film. The simultaneous fitting of this data revealed the presence of different components that were not at all distinguishable by visual inspection. The strong dependence of the spectrum shape on the take-off angle allowed for the deconvolution. 5/7

Si 2p @ 25 silicon in SiC (99.9eV) 300 10min vacuum bulk silicon (99.4eV) silicon dispersed in graphite (100.6eV) Si oxide (103.2eV) Si suboxide (102.2eV) last layer of bulk silicon (99eV) Kinetic Energy (ev) Figure 5. Silicon chemical species present in the DLC-E 15Å film. The dependence of the shape on angle can be quantitatively observed in Figure 6, which shows the dependence of the intensity of each component on the take-off angle. Si 2p bulk Si (99.4eV) 300 10min vacuum Si in SiC (99.9eV) Si dispersed in graphite (100.6eV) suboxide & oxide(102.2 & 103.2eV) Take-Off Angle Figure 6. Angular dependence of the silicon species present in the film. The question then becomes why multifile simultaneous fitting is not widely used. This can be partially answered by a computational difficulty. The total number of variables that has to be determined is large. In the example for oxygen mentioned above, the total number of parameters that were simultaneously optimized was 14. However, it is common to encounter cases where 6/7

the number of optimized parameters reaches 70 or even more. Take the case of the data in Figure 5 (the complete set of data is shown in Figure 4 and the take-off angular dependence is shown in Figure 6). The spectra are composed by six peaks, which represent by themselves twelve parameters. Twelve spectra were analyzed, corresponding to six angles before and after annealing. Then, 72 areas had to be determined. This gives a total of 86 parameters to be determined from the whole data. To assess them simultaneously becomes formidable even for the most powerful algorithms, such as Levenberg. So, they are usually determined in the way described in Section III. None of the commercially available fitting software can handle this, so it was necessary to write our own algorithm. This algorithm is the heart of AAnalyzer, our program for XPS data fitting. References 1 2 3 4 5 6 7 Quantification of pinhole density in ultrathin diamond-like carbon films. A. Herrera-Gomez, F. S. Aguirre-Tostado, Y. Sun, R. Contreras-Guerrero, R. M. Wallace, Y. Hisao and E. Flint. Rapid Communication, Surface and Interface Analysis. 39, p.904 (2007). X-ray photoelectron spectroscopy study of the oxidation of Se passivated Si(001). F.S. Aguirre-Tostado, D. Layton, A. Herrera-Gomez, R.M. Wallace, J. Zhu, G. Larrieu, E. Maldonado, W.P. Kirk, and M. Tao. J. Appl. Phys. 102, 084901 (2007) Composition depth profile study of nitrided HfSiON/SiO2/Si(001) ultrathin films. International Conference on Material and Interfaces, March 2006. Austin, Texas. The Structure of Carbon Films from High Resolution ARXPS. Alberto Herrera-Gomez, Servando Aguirre-Tostado, Robert M. Wallace, Eric Sun and Eric Flint. Final Report for Hitachi Global Storage Technologies. San Jose, California, 95193. December, 2006. Chemical depth profile of ultrathin nitrided SiO2 films. A. Herrera-Gómez, A. Hegedus, P.L. Meissner. Applied Physics Letters 81, p. 1014 (2002). Chemical depth profile study of ultrathin nitrided SiO2 films. A. Herrera-Gómez. Final Report for the Thermal Processing Division, Applied Materials, Inc. (October, 2001). A. Herrera-Gomez, J. T. Grant,3 P. Cumpson, M. Jenko, C.R. Brundle, T. Conard, G. Conti, C.S. Fadley, J. Fulghum, K. Kobayashi, L. Kover, H. Nohira, R.L. Opila, Steffen Oswald, R. Paynter, W.S.M. Werner, and John Wolstenholme. Report on the 47th IUVSTA Workshop Angle-Resolved XPS: The Current Status and Future Prospects for Angle-resolved XPS of Nano and Subnano Films. Surf. Interface Anal. (2008). 7/7