Mission-critical fire protection HI-FOG for data centres



Similar documents
Mission-critical fire protection HI-FOG for large data centres

Fire Protection of Data Centres

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

For Data Center and Control Room Applications

- Save lives and reduce material damage

For Data Center and Control Room Applications

- Save lives and reduce material damage

Challenges for Use of Fixed Fire Suppression Systems in Road Tunnel Fire Protection

Firefighter Review. Instructor Guide

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

EFSN Training i Module Minutes

Fire Suppression Systems for Your Home

Malaysia s Leading Data Center Facilities Provider CORPORATE PROFILE

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

F.Y.I. Specifying Fire Protection Systems Using Division 13

Sprinkler Systems in Hospitals. Lisbon 6 November 2008

Breakthrough Solenoid Valve Technology for Upstream Oil and Gas Heating Equipment

Fire Protection Options for Data Centres

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

IWMC 2015, Amsterdam, October 28-29, 2015 Practical experience from actual water mist installations. What can be learnt?

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Watermist fire suppression systems for commercial low hazard occupancies

Risk Guidance Note 03. Management of In-Rack Automatic Sprinklers (IRAS)

Denver Museum Of Nature & Science 2001 Colorado Boulevard Denver, Colorado Fire Suppression & Alarm System Upgrade. General Contractor

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

Fighting Fire in Sprinklered Buildings. Student Guide

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Maintaining Fire Protection Systems

How intelligent must an extinguishing solution be to keep fire virtual?

Get the benefits of Norgren s unique range of Online services

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

SimSafe Data Centre Standards and Accreditation

Premium Data Centre Europe Pricing, Business Model & Services

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

White paper. SAS Solutions OnDemand Hosting Overview

DATA CENTERS BEST IN CLASS

The Region s Leading Data Center Developer, Manager and Operator C O R P O R A T E P R O F I L E

Application management services that power business transformation

The Region s Leading Data Center Developer, Manager and Operator

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

DATA CENTER FIRE PROTECTION

Risk Management Guidelines

The Mission Critical Fire Protection Experts

Maximum uptime and optimum fire safety for your data center

Data Centre alwas protected always up and running.

The Lawson Customer Relationship Management Solution

Building Technologies

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

All Products Brochure

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

Maximum uptime and optimum fire safety for your data center

Understanding the new lead-free water system regulations and choosing valves to comply

Fire suppression in buildings using water mist, fog or similar systems

Fire Protection on Site: The VdS Inspection Services

Appendix B Forms for Inspection, Testing, and Maintenance

Case Study BOEING 787: GLOBAL SUPPLY CHAIN MANAGEMENT TAKES FLIGHT. Leveraging Global Partners to Maximize Customer Value

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

THE PROXBOOK REPORT THE STATE OF THE PROXIMITY INDUSTRY Q All information in this report belongs tounacast AS

Scalable. Affordable. Flexible. Fast.

T:

Data Center Presentation

NeuStar Ultra Services Physical Security Overview

QUICK FACTS. Replicating Canada-based Database Support at a New Facility in the U.S. TEKSYSTEMS GLOBAL SERVICES CUSTOMER SUCCESS STORIES

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Company Profile Outstanding data centres. Expertise you can trust. Europe s leading provider of premium carrier-neutral data centres.

WANT TO STRENGTHEN YOUR CUSTOMER RELATIONSHIPS? THE RIGHT SALES STRATEGY WILL HELP

our service / Expertise Global Reach Financial Security Bespoke Approach Claims Management

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

GLOBAL SWITCH ALWAYS ON

Natural geothermal energy.

Facility Operations Physical Safety Guidance Document

Business Voice BT s Managed Global Voice Solution

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Powering Today and Tomorrow. Energy Solutions

Application of Fuel Cells to Fork Lift Trucks

White Paper FASTFILE / Page 1

POWERING A CONNECTED ASIA. Pacnet Hong Kong CloudSpace1 Technical Specifications. Asia s Pioneering Facility with Direct Subsea Cable Access

Cost-effective solutions for all applications.

ICT Priorities in Pharmaceuticals

AMDOCS CRM FOR FINANCIAL SERVICES INSTITUTIONS

TYPE APPROVAL CERTIFICATE

Setting a Global Standard. SingleBore Subsea Completion System

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Effectiveness assessment of road tunnel fire-fighting strategies by ventilation and water mist systems

Transcription:

Mission-critical fire protection HI-FOG for data centres

Modern fire protection

for a data-driven world We make a strong case that HI-FOG is the best available fire protection for mission-critical data operations and infrastructure. The proof is in the performance and the growing list of satisfied HI-FOG data centre customers. The HI-FOG Water Mist Fire Protection System suppresses fire using the world s most widely available and environmentally friendly fire-fighting agent water. It is entirely safe for people and the environment. HI-FOG uses special, patented nozzles to produce an extremely fine mist of micro-droplets representing water in its most effective fire-fighting form. The micro-droplets penetrate fire very efficiently, cooling the surrounding air effectively and blocking radiant heat, preventing the fire from spreading. Fire, water, smoke and heat damage are minimized. Clean-up is fast. Business downtime is kept to an absolute minimum. HI-FOG provides total facility fire protection: Server areas Sub-floors Back-up power generator rooms Chiller/HVAC rooms UPS room Storage rooms Electrical rooms Common areas: corridors, meeting rooms, offices A typical HI-FOG system for data centres consists of: A high-pressure pump unit A small water supply tank (optional, depending on requirements) Section valves Small-diameter stainless steel tubing Fast-activating HI-FOG sprinkler heads or spray heads

Synchronized to your business HI-FOG can be configured according to the modular design of modern data centres and your business requirements. HI-FOG is easily expanded to protect new areas as your data centre grows: the tubing network is extended to cover the new areas and HI-FOG sprinkler heads are added. The single, centralized pump unit can serve wide areas over long distances. HI-FOG is easily adapted to changing space requirements in a single data centre, or across an international network of data centres. HI-FOG s flexibility is appreciated by many of Marioff s current data centre customers. It helps them evolve in step with the needs of their clients, some of whom are moving very fast indeed.

Part of environmentally sustainable design HI-FOG is green fire protection. It uses up to 90% less water than a traditional sprinkler system and offers equivalent or better performance. It is a clean system that uses plain, potable water (no black water problems). It consumes little electricity and does not impose special requirements on your building. HI-FOG is made of high-quality materials for long system life, low maintenance and a minimized risk of leakage and false discharge. Stainless steel HI-FOG tubes are much narrower in diameter than traditional sprinkler system pipes: 12 mm tubes will typically make up two-thirds of a HI-FOG system. HI-FOG s low water requirement, low space requirement and low system weight give design consultants and system engineers precious room to maneuver in coming up with impressively green data facility solutions. If green building design is about turning small, incremental savings into big savings over time, HI-FOG can help point the way. HI-FOG maximizes water s fire fighting capability by generating a very large surface area of water within the volume of space. HI-FOG water mist is unparalleled in its ability to attack two of the three pre-requisites of fire heat and oxygen (the combustible material being the third) while being harmless to people and the environment. Conventional sprinkler / water spray Low-pressure water mist Typical drop size range (mm) 1 5 15 thousand to 2 million 1 6 0.2 1 2 million to 250 million 6 30 0.025 0.2 Number of droplets per litre of water 250 million to 150 billion Superior cooling and local inerting Surface area (m 2 ) 30 250 Superior blocking of radiant heat

The view from A walk through the LD4 IBX Marioff is a preferred fire protection solution supplier to Equinix in the UK. HI-FOG protects six Equinix data centres in Europe, four in the London area. HI-FOG protects Equinix s LD4 International Business Exchange (IBX ) data centre in the west London area, a showcase facility in the industry. Built from the ground up for Equinix with every detail carefully considered, the result is one of Europe s most advanced data centre environments. A dry-pipe HI-FOG system provides total facility protection with: A GPU6 pump unit 1,200 HI-FOG 1000-series sprinklers 18 section valves 12 mm and 30 mm tubing

Equinix UK data centre The system protects all the critical data centre space and the UPS rooms, covering two floors over an area of 13,800 m 2. Gas-based fire protection systems are commonly used in the UK for data centre fire protection. Equinix believes that HI-FOG offers important advantages over such systems: It does not require alterations to be made to the building fabric in order to accommodate the large pressure changes experienced with gas discharges HI-FOG s system footprint is much smaller than that of gas systems Installation is fast and costeffective with no loss in quality

Protecting data centres CX2 Cyberjaya science township, Kuala Lumpur, Malaysia This data hotel, the largest of its kind in South-East Asia, provides outsourcing services with two interconnected wings of 5 and 6 storeys. A HI-FOG system composed of wet-pipe, deluge and preaction sections protects roughly 95% of the facility: 9,000 m 2 of server areas, sub-floors, a back- up power generator room, electrical rooms, UPS rooms, offices and public areas. The system comprises an SPU4 pump unit, 2,800 HI-FOG sprinkler heads and spray heads, and 17 section valves. HI-FOG was chosen due to Marioff s reputation as a trusted partner and its reference list of satisfied data centre operators.

around the world Telecity IV data centre, Amsterdam, the Netherlands A wet-pipe HI-FOG system protects the high-value spaces: five server halls and the power generation areas. Both the hot and cold isles are protected in the data spaces. HI-FOG was selected over competing technologies because it could be used to protect all the identified risk areas. TCN Eemsdelta Data Centre, Eemshaven, the Netherlands This facility is the largest and most advanced data storage and hosting centre in the Netherlands, with free air cooling and green energy technology. HI-FOG protects the entire building. It was chosen for its performance, economic feasibility and suitability for the location.

A trusted partner A number of leading data centre operators have joined forces with Marioff to neutralize the threat of fire. This is a long-term proposition, and Marioff supports HI-FOG over the complete lifecycle of the system. Design services Marioff will design the right HI-FOG system for your data centre based on the size of the areas to be protected, your need for modularity, and any special requirements such as sub-floor protection. Installation Marioff and its partners are expert at installation. In a working data centre, HI-FOG is installed wing by wing and space by space in accordance with your operations. Low maintenance costs, long system life The HI-FOG system is made of highquality components and stainless steel tubes to ensure long system life and minimal maintenance costs. Marioff provides a full palette of services to ensure that your HI-FOG system stays in peak operating condition throughout its lifecycle. Environmentally friendly HI-FOG uses very little water to ensure environmentally safe and responsible performance. The system will not fall foul of future environmental regulations. Training As part of your overall safety and security regimen, Marioff will train your staff to operate the HI-FOG system to make sure it performs at its best when it really matters all the time.

Regulatory background HI-FOG development is based on full-scale fire tests that are evaluated by independent, third-party authorities. Since its launch in 1991, HI-FOG has received over 100 type approvals as a result of over 6,000 full-scale fire tests conducted to date for marine, building, industry and energy applications. HI-FOG systems for buildings are designed and installed according to the NFPA 750 Standard on Water Mist Fire Protection Systems. HI-FOG systems for the fire protection of buildings have system approvals for the following sprinkler classes: Light hazard (FM) Ordinary hazard 1(VdS) Ordinary hazard 3 (VdS) FM and VdS approval Additionally, HI-FOG systems for the protection of the following hazard areas relevant to data centre operations have been approved by FM Global, VdS or the IMO: Machinery spaces Car parks (OH2)

Shown actual size: 12 mm tube to the HI-FOG sprinkler/spray heads HI-FOG 1000-series sprinkler Shown actual size: 30 mm tube HI-FOG 2000-series sprinkler HI-FOG spray head Gas-driven pump unit (GPU) SPU8 electric pump unit. Provides constant flow of 140 bar pressure during activation. Can be reset quickly and automatically after a discharge. Head Office Marioff Corporation Oy Virnatie 3 FI-01301 Vantaa, Finland Tel. +358 (0)9 8708 51 Fax +358 (0)9 8708 5399 Email: info@marioff.fi Austria Canada Finland France Germany Italy Russia Spain Sweden UK USA Information on Marioff group companies, agents/distributors and references can be found at www.marioff.com. Marioff Corporation Oy reserves the right to change or modify the information given in this brochure, including technical details, without notice. HI-FOG and Marioff are registered trademarks of Marioff Corporation Oy. Marioff is part of UTC Fire & Security, which provides fire safety and security solutions to more than one million customers around the world. Headquartered in Connecticut, USA, UTC Fire & Security is a business unit of United Technologies Corp., which provides high technology products and services to the building and aerospace industries worldwide. More information can be found at www.utcfireandsecurity.com. All rights reserved. Reproduction of any part of this brochure without the express written permission of Marioff Corporation Oy is prohibited. 2112A-EN 2009 Marioff Corporation Oy