Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village



Similar documents
Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

The ABC of Direct Attach Cables

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Datasheet: DSX-5000 CableAnalyzer

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

SignalTEK II. Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

How To Make A Data Center More Efficient

Upgrading Path to High Speed Fiber Optic Networks

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Obsolete Fiber Technology? Not in my Data Center!

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Network Design. Yiannos Mylonas

Optimizing Infrastructure Support For Storage Area Networks

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Loss & Continuity Testing with MPO/ MTP Connectors

IT Cabling Solutions

The Need for Low-Loss Multifiber Connectivity

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

Anticipating the Future

How to Choose the Right Cable Category

Fibre optic testing best practices

Data Center Design for 40/100G

Understanding Fiber Polarity: Implications at 10G, 40G, & 100G

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Your Network. Our Connection. 10 Gigabit Ethernet

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Total Solutions Verification

Security & Surveillance Cabling Systems

Gigabit Ethernet on Copper Cabling Infrastructures

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

The 8-Fiber Solution for Today s Data Center

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

CISCO 10GBASE X2 MODULES

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Overcoming OM3 Performance Challenges

100BASE-SX Fast Ethernet:

Trends In Data Rate And Link Length In Evolving Optical Standards

Enhanced Category 5 Cabling System Engineering for Performance

SYSTIMAX Copper Solutions Designed for the Digital Generation

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

How To Properly Maintain A Fiber Optic Infrastructure

MIGRATING TO A 40 GBPS DATA CENTER

Data Center Cabling Technology and Trends

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

NaviTEK II. idealnwd.co.uk. Save money through using a single multifunction device for testing copper and fibre networks

Trends and Standards In Cabling Systems

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

MTP Optical Fibre Configurations

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Copper Cabling Troubleshooting Handbook

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

Innovative Connectivity Solution for Maximum Performance and Security

Gigabit Switching Ethernet Media Converters - Product User Guide

Power over Ethernet technology for industrial Ethernet networks

White Paper. MPO/MTP Introduction to Parallel Optics Technology

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

Advantages of 4 th Generation CAT 6A UTP Cables. Antonio Cartagena Business Development - Caribbean Leviton Network Solutions

The Ethernet Roadmap Applications, servers, optics, and switches

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

Data Center Architecture with Panduit, Intel, and Cisco

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Chapter 4 Connecting to the Internet through an ISP

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Low Cost 100GbE Data Center Interconnect

Corning Cable Systems Optical Cabling Solutions for Brocade

Connector and Cable Specifications

AMP NETCONNECT Data Center Cabling Solutions

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

10/100/1000 Base-T to Gigabit Fiber Media Converter

WHITE PAPER December, 2001

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Arista 40G Cabling and Transceivers: Q&A

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Transcription:

Brno, Marec 2014 Physical Infrastructure trends and certification requirements for Datacenters Ing. Peter Potrok PROFiber Networking s.r.o. Psiber s Global Village London Munich San Diego Boston Paris Milano Singapore Hubs providing R&D, Infrastructure and Service Sales Offices 1

Moving towards Higher Speeds Demand Increased Users Broadband, NBN penetration Increased Access rates Multiple Access schemes, Wi Fi, FTTH, LTE Source: Psiber Data Pte Ltd Increased Services Social Media explosion, Content on Internet Massive data requirements due to video traffic, Gaming, Forecast Global data center traffic Annual global data center IP traffic will reach 6.6 zettabytes by the end of 2016. By 2016, global data center IP traffic will reach 554 exabytes per month (up from 146 exabytes per month in 2011). Global data center IP traffic will nearly quadruple over the next 5 years. Overall, data center IP traffic will grow at a compound annual growth rate (CAGR) of 31 percent from 2011 to 2016. Global cloud traffic: Annual global cloud IP traffic will reach 4.3 zettabytes by the end of 2016. By 2016, global cloud IP traffic will reach 355 exabytes per month (up from 57 exabytes per month in 2011). Global cloud IP traffic will increase six-fold over the next 5 years. Overall, cloud IP traffic will grow at a CAGR of 44 percent from 2011 to 2016. Global cloud IP traffic will account for nearly twothirds of total data center traffic by 2016. 2

Big Data Higher Speed for better Quality of service per datacenter/customer profile. Source: Cisco 802.3bq: Why? The IEEE 802.3bq Task Force is chartered to extend the Ethernet protocol to operating speeds of 40 Gb/s over 4-pair balanced twisted-pair copper with a reach of up to at least 30 meters. The project was substantiated on the market need for a low cost 40 Gb/s solution backward compatible to IEEE 802.3 BASE-T family of technologies for data center applications 40GBASE-T will enable network managers to scale their networks to 40 Gigabit speeds while maintaining backward compatibility with 1000BASE-T and 10GBASE- T leveraging the cost-effectiveness and plug-and-play simplicity of copper structured cabling. Ethernet BASE-T port types support auto-negotiation allowing the transceivers to exchange capabilities and agree on the highest speed that both can support. 3

Infrastructure: Copper Achieving 40Gbps in copper For < 7m Standard exists (CR4) (used within Racks) Occupies a lot of space per Gbps compared to BASE-T Short reach mostly intra-rack connectivity But most commonly used lengths are between 10 and 30m Evolving CAT8 Standard.(30m, capable of EoR) Bandwith Today and Future Categor y Eventualy ARJ45 TIA prefer RJ Technology WX 4500 WX 500 4

Measurement Dynamic Wiremap Loop Resistance Cable Length Near End Crosstalk (NEXT) PowerSum NEXT Insertion Loss (Attenuation) ACR-N PowerSum ACR-N Return Loss (RL) ACR-F (ELFEXT) PowerSum ACR-F Propagation Delay Required Measurements Description Accurately detects Open/Short and Distance to Fault from both ends of the cable The resistance between the two conductors of a twisted pair which is looped back at the far end The length of the cable under test The interference at the near end of a pair caused by signal on another pair The sum of the individual NEXT effects on each pair by the other three pairs The decrease in signal strength from one end of the cable to the other The difference between insertion loss and near-end crosstalk (NEXT) The sum of the individual ACR-N effects on each pair by the other three pairs Signal loss caused by structural imperfections in the cable The interference at the far end of a pair caused by signal on another pair, with the insertion loss subtracted The sum of the individual ACR-F effects on each pair by the other three pairs Time it takes for a signal to travel from one end of a cable to the other Delay Skew The difference in time between the fastest and slowest pairs within a cable Wirexpert Most Advanced Cable Certifier Capable of certifying Category 5e, 6, 6A, 7, 7A as well as tomorrow s 2 GHz Category 8 standard currently being worked on by TIA. Fastest Category 6A Autotest time (9 seconds) and fastest fiber optic test time (8 seconds). MPO/MTP test adapter option provides the most advanced and user friendly MPO/MTP testing solution. Fastest patch cord test solution; 9 seconds with one page customizable test report versus competitors > 1 min minute with a two page report. Color graphic touch screen allows our engineers to add features through simple firmware updates. Similar to a smartphone. 5

Dual control system - dcs Dual Control System (DCS) - Local unit and Remote unit are identical, which means the test can be performed from either end of the cable and results can be saved or analyzed at either end. Dramatically improves operator efficiency. Reduce time walking by 50% Certification can be carried out by just one technician. 2 sets of WireXperts can be configured as 1 main unit with three remotes. Memory is locked on Remote units so all test results are stored in one location on the Local device. Infrastructure: Fiber Achieving 40 Gbps on Fiber Use of Parallel Optics through QSFP connectors and MPO arrays IEEE 40G BASE-SR4 Mostly Multi-mode preferred for Datacenter applications TIA 942-A requires use of OM3 Fiber Needs 8 ports of the MPO array Parallel optics already in use in backplanes today Connecteur 12-fibres MPO/MTP 6

Certifying 10G/40G on Fiber As the optical budget is becoming tighter and tighter for bigger Data rate, testing tools must be more accurate with less uncertainty! EF compliance required by ISO 11801 document for multimode sources TIA adopting a similar standard specified Requirement on Light source for Multimode certification What is Encircled Flux? Amount of light coupled to a MM Fiber What is Encircled Flux? 50 um Near Field Pattern of EF Compliant LED Near Field Pattern of 850nm VCSEL 7

Optical modules Multimode Encircled Flux Encircled Flux EF compliant Optical modules Multimode Encircled Flux Interchangeable connector system (SC/ST/LC) Faults detection (VFL) 8

MPO Testing Solution WireXpert 4500. Kit Contents 1. Local Adapter (To be plugged into the local unit). Power Meter 2. Remote Adapter (To be plugged into Remote unit) Light source 3. 2 Type A(Key up-key down) pinned to unpinned cords 4. 1 Type A unpinned to unpinned cord 5. 1 Type B unpinned to unpinned cord 6. 1 one-click MPO cleaner 7. 2 MPO mating adapters 9

MPO Testing: Limit Selection Select 40G/100G limit Based on the fiber type, OM3/OM4 and the application selected, the loss limit is applied. The channels are appropriately selected when the test limit is selected. Testing with premise limits and MTP light source/ Power Meter Testing Results Tests absolute power, loss and polarity 10

Questions? Ďakujem za pozornosť. Ing. Peter Potrok PROFiber Networking s.r.o. 11