Encore SATA2 RAID PCIe Card



Similar documents
Serial ATA RAID PCI Card

6-Port SATA II 150 PCI Host Card w/raid

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

PCI ATA 133 RAID Controller Card. User Manual

SATA II PCIe RAID Quick Installation Guide

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

SATA II PCIe RAID Quick Installation Guide

Serial ATA 4-Channel RAID Quick Installation Guide

Serial ATA RAID PCI. User's Manual

User manual Ver: 2.0. SATA Channel PCI RAID Card

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

PCI SATA + PATA Raid Card

SATA 150 RAID. user. Model MAN UM

SATA II-150 PCI RAID

SATA II 4 Port PCI RAID Card RC217 User Manual

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

esata 3.0Gbps RAID ExpressCard

SATA 6G PCIe Card User Manual Model: UGT-ST622

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

SATA II-150 PCI Quick Installation Guide

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

PCIe SATA 6G Raid Card

RAID installation guide for Silicon Image SiI3114

Ultra ATA 133 RAID PCI Pro

Low Profile Ultra ATA-133 RAID PCI Host

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

PCI SATA Controller Card Model: SY-PCI40010

Serial ATA 2 Ports PCI Host

RAID installation guide for ITE8212F

Serial ATA PCI Quick Installation Guide

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

Guide to SATA Hard Disks Installation and RAID Configuration

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

SATARAID5 Serial ATA RAID5 Management Software

UltraATA 100 PCI RAID TM

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

VIA / JMicron RAID Installation Guide

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

SATARaid Serial ATA RAID Management Software

SERIAL ATA HOST CONTROLLER CARD USER MANUAL SATA R SATA I WARNING

VIA RAID configurations

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

VT8237 SATA RAID User Manual

4 Port PCI SATA RAID Controller Adapter Card

NVIDIA RAID Installation Guide

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

ESATA PCI CARD. User s Manual

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

Chapter 2 Installation

RAID Option Installation

ITE RAID Controller USER MANUAL

SATA/eSATA II PCI & PCI-E Card & CardBus

SATA RAID Function. (Only For Chipset Sil 3112 /Sil 3512 Used) USER S MANUAL 12M E-SI

Promise FastTrak 100-Lite RAID Controller

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

AMD RAID Installation Guide

VIA RAID Installation Guide

AMD RAID Installation Guide

Intel Matrix Storage Manager 8.x

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

Intel Rapid Storage Technology

English. Configuring SATA Hard Drive(s)

Serial/ Parallel Combo PCi Card user manual

PCIe Gigabit Ethernet Card

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Intel ESB2 SATA RAID Setup Guidelines

Guide to SATA Hard Disks Installation and RAID Configuration

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

2-Serial/1-Parallel Port PCI Adapter

SATA PCI Express Adapter PEXSATA22I

2 Port esata or 4 Port SATA II PCI Express x4 Controller Card

SiI3132 SATARAID5 Storage Management Software User Manual

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

USB Port PCI Express Card

USB Port PCI Express Card

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

ATA-133 IDE RAID Card. Version 1.1

RocketRAID User, s Manual. Revision: 1.0 Date: Sept HighPoint Technologies, Inc.

RAID configuration and driver installation guide

2.5" XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (X Series) 1.

AMD RAID Installation Guide

Configuring ThinkServer RAID 100 on the TS140 and TS440

SATARAID5 Management Software User s Guide

DESKTOP. Internal Drive Installation Guide

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

Transcription:

Encore SATA2 RAID PCIe Card User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. 1

Features and Benefits Compliant with PCI Express Base Specification 1.0a Compliant with Serial ATA 1.0 specification with support for full complement of SATA II optional features Installs in any available PCI Express slot and supports data transfer rates up to 3.0Gbps Supports Native Command Queuing (NCQ), Non-zero offsets NCQ, and Out-of-order data delivery NCQ Supports RAID 0(striping) and RAID 1(mirroring) for speed and data protection respectively System Requirements PCI Express-enabled system with one available PCI Express slot Windows 2000/XP/Server 2003/Vista Package Contents 1x Encore SATA2 RAID PCIe Card 1x Driver CD 1x SATA Data Cable & 1 x SATA Power Cable 1x Manual 2

Hardware Description 3

Jumper Settings JP Description Active Port J1-J4 1-2 close Enable SATA Connector 1 2-3 close Enable SATA Connector 3 J5-J8 1-2 close Enable SATA Connector 2 2-3 close Enable SATA Connector 4 Note: There are four SATA ports in Encore SATA2 RAID PCIe Card. We named these ports character A through D. Ports A & B are external SATA ports and C & D are internal SATA ports. By changing the jumper setting on Encore SATA2 RAID PCIe Card that allows you to utilize 2 ports of this card at the same time. Please set which port to work by jumper setting. By default, Port C and D are working. Hardware Installation 1. Turn Off the power to your computer and any other connected peripheral devices. 2. Unplug the power cord from the back of the computer. 3. Remove your computer s cover. 4. Remove the slot bracket from an available PCI Express slot. 5. To install the card, carefully align the card s bus connector with the selected PCI Express slot on the motherboard. Push the board 4

down firmly, but gently, until it is well seated. 6. Replace the slot bracket s holding screw to secure the card. Device Connection Serial ATA hard drives should come with their own accessories. In most cases, you just need to power up the device and connect them to the ports. The Encore SATA2 RAID PCIe Card is two channel Serial ATA controller that supports two Serial ATA hard disk drives. It is recommended to use identical drives for all RAID configurations. However, it s possible to combine hard drives of different sizes and makes. RAID Arrays RAID Arrays are setup in the SiI 3132 SATA PCIe RAID adapter s BIOS. RAID 0 (Striping) This RAID array to be used on New/Blank hard drives. Striping will destroy existing data on the hard drive. Auto Configuration is recommended. For applications that require custom chunk size, Manual Configuration is offered. 5

Auto configuration (recommended) The default chunk size is 64k when selecting Auto configuration. 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. Select RAID0, then press Enter. 4. Select Auto configuration, then press Enter. 5. Input the RAID size, press Enter. 6. When asked Are You Sure (Y/N)?, press Y to accept. 7. Press Ctrl+E to exit the BIOS. 8. When asked Are you sure to exit (Y/N)?, press Y to exit and reboot. 9. Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive. Manual configuration 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. Select RAID0, then press Enter. 4. Select Manual configuration then press Enter. 6

5. Select chunk size from 8k, 16k, 32k, 64k or 128k, then press Enter. 6. Select the first drive, press Enter. 7. Select the second drive, press Enter. 8. Input the RAID size, press Enter. 9. When asked Are You Sure(Y/N)?, press Y to accept. 10. Press Ctrl+E to exit the BIOS. 11. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. 12. Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive. RAID 1 (Mirror) For New/Blank Hard Drives 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. At the next screen select RAID1 then press Enter. 4. Select Auto configuration, then press Enter. 5. Input the RAID size, press Enter. 6. When asked Are You Sure(Y/N)?, press Y to accept. 7

7. Press Ctrl+E to exit the BIOS. 8. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. 9. Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive. For Existing Hard Drives with Data 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. At the next screen select RAID1 then press Enter. 4. Select Manual configuration, then press Enter. 5. Select the Source drive, press Enter. 6. Select the Target drive, press Enter. 7. Select Create with data copy, then press Enter. 8. Select online copy, then press Enter. Note: Selcting Online Copy builds the mirror while in Windows. Selecting Offline Copy builds the mirror before exiting the RAID BIOS. 9. Input the RAID size, press Enter. 10. Press Ctrl+E to exit the BIOS. 8

11. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. CONCATENATION (JBOD) This RAID array allows you to use one or two hard drives to a JBOD(Just a Bunch Of Disks) array. Although JBOD doesn t offer other RAID functionality, it makes the hard disks appear to be a single one by combining the drives into one larger logical one without any capacity loss. Rebuilding a Failed Mirror Set When a failure to one member occurs, you will be notified by the RAID BIOS during boot. The steps below will guide you in rebuilding a failed mirror set. 1. Replace he failed drive(s) with one of equal or greater capacity, then start the computer. 2. During boot press Ctrl+S or F4 to enter the RAID BIOS. 3. Select Create RAID Set press Enter. 4. Select SPARE DRIVE, then press Enter. 5. Select the single hard drive then press Enter. 6. Input RAID size, press Enter. When asked Are You Sure(Y/N)?, 9

Press Y to confirm. 7. Select Rebuild Raid 1 Set, press Enter. 8. When asked Are you sure(y/n)?, press Y confirm. The mirror will begin rebuilding. Do not interface with process. 9. When rebuilding is finished, press Ctrl+E. 10. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. Deleting RAID Arrays 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. Select Delete RAID Set, then press Enter. 3. Select the RAID set then press Enter. 4. When asked Are You Sure(Y/N)?, press Y to confirm. Resolving Conflicts When a RAID set is created, then metadata written to the disk includes drive connection information. If, after a disk failure, the replacement disk was previously part of a RAID set (or used in another system), it may have conflicting metadata. If so, this will prohibit the RAID set from being either created or rebuilt, in order for the RAID set to 10

function properly, this old metadata must be first overwritten with the new metadata. To resolve this, from the main BIOS window select Resolve Conflicts, then press Enter, the correct metadata, including the correct drive connection information, will be written to the replacement disk. Low Level Format Low Level Format is build into the RAID BIOS to make it more convenient to erase the entire contents of a hard disk drive, including data, drive and partition information. The Low Level Format utility works on single hard drive only, before the RAID set is configured. Logical Drive Info This menu item allows the display of the assignment of physical drives within a logical set(raid0, RAID1, etc.). This is display only function. BIOS Configuration The SiI 3132 SATA II PCIe RAID adapter BIOS will appear every time your system starts up. If the BIOS doesn t show, please try your 11

controller in another PCI Express slot. During this (POST) process, the BIOS will show up and indicate the devices attached to it. Driver Installation For Windows XP/Server 2003 For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the Driver\x86 folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press F6 to install the RAID driver. 5. When prompted, press S to specify the location of the driver. 6. Insert the floppy disk, then press Enter. 7. Select Silicon Image SiI 3132 SoftRAID 5 Controller for Windows XP/Server 2003, then press Enter. 8. Press Enter to finish driver installation, then follow the on-screen instructions to complete the Windows installation. Note: If the Security Alert warning pops up, click Yes. Our driver has 12

passed Microsoft compatibility testing, this message appears during new installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At the Found New Hardware Wizard: XP(w/SP1 or earlier)/server 2003: continue to step #3 XP(w/SP2 or later)/server 2003(w/SP1 or later): select No, not this time, then click Next. 3. Insert the driver CD, select Install the software automatically (Recommended), and click Next. 4. Accept the default entry, then click Next. 5. Click Finish. 6. Repeat steps 2-5. 7. Click Yes to restart to complete the installation. For Windows 2000 For A New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of 13

the Driver\x86 folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Windows 2000 installation procedure. 3. Restart the computer when prompted by the installation. 4. At the Windows 2000 Setup screen, press F6 to install the RAID driver. 5. When prompted, press S to specify the location of the driver. 6. Insert the floppy disk, then press Enter. 7. Select Silicon Image SiI 3132 SoftRAID 5 Controller for Windows 2000, then press Enter. 8. Press Enter again to finish driver installation, then follow the on-screen instructions to complete the Windows installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At Found New Hardware Wizard, click Next. 3. Select Search for a suitable driver for my device(recommended) then click Next. 4. Insert the driver CD, check CD-ROM drives, uncheck the other 14

boxes, click Next, then click Next again. 5. If the Digital Signature Not Found message appears, click Yes. Our driver has been thoroughly tested for stability and compatibility. 6. Click Next, then Finish. 7. Repeat steps 2-6. 8. Click Yes to restart to complete the installation. For Windows Vista For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the Driver\x86 folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press Load Driver to install the RAID driver. 5. Insert the floppy disk, please select Silicon Image SiI 3132 SoftRaid 5 Controller (A:\si3132r5.inf), then press Next. 15

(Change A:\ to match your floppy drive letter) 6. Follow the on-screen instructions to complete the Windows installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At Found New Hardware Wizard, select Locate and install driver software (recommended). 3. Please insert the CD driver bound with Encore SATA2 RAID PCIe Card into your CD-ROM Drive, click Next. 4. If the system prompts the user informing the drivers are not signed, select the option Install this driver software anyway. 5. Click Close to complete the installation. To Verify Windows 2000/XP/Server 2003 Installation 1. Right click My Computer and click Manage. 2. Select Device Manager. 3. Double click SCSI and RAID Controller, then double click Silicon Image SiI 3132 SoftRaid 5 Controller to display driver 16

properties. A message this device is working properly is displayed in the dialog box, the driver has been correctly installed. For Technical Support and installation hotline, Please visit our website at http://www.encore-usa.com 17