ipc10 ipc20 Operating Instruction isel Germany AG, D-36124 Eichenzell, Bürgermeister-Ebert-Str. 40 (06659)981-0 (06659)981-776



Similar documents
1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

7 x USB x 5V PoweredUSB on the rear panel. 2 x USB on the rear panel 2 x 5V PoweredUSB on the bottom panel

Scout 1U Rackmount Computer

Waveguide Access Point WGA631. Product Guide

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

DCS Data and communication server

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

SB9011D All-in-one Touch POS Terminal USER MANUAL

Communication Unit 560CMU05 Data sheet

Fujitsu PRIMERGY BX600 S3 Blade Server

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Server Rack Commissioning

Box PC Fanless. Box PC Performance

2100 POS System User Guide

Panel PC SIMATIC HMI IPC577C

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

Specifications. Product Description 18.5" Fanless, Intel ATOM D GHz Processor, Multi Function Panel PC

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

CPU Chipset Platform LCD Size Model 12" EP " EP

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

DCS data and communication server

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

TrueAlarm Fire Alarm Systems

Programmable Power Supply HM7044

=============================== WARNING

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Light Industrial Panel PC

Chapter 5 Cubix XP4 Blade Server

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

MAVO-MONITOR USB. Page. 1 Applications Display The elements of the display Key pad... 2

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7" Touchscreen. Feature Highlight.

VariPOS. All-in-One & Multi-touch POS Solutions. Enhancing Your Hospitality and Retail Business

Installation and Operating instructions for. Control Cabinet Industrial PC C Version: 1.3 Date:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cisco MCS 7825-H3 Unified Communications Manager Appliance

MagIC Installation Manual. Point of Sales Terminals TD06014B

Cisco 7816-I5 Media Convergence Server

Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

YoungPOS Presentation.

is then retained absolutely without interruption.

STRATO LED Drivers 70W, Single output

Datasheet. The cost-optimized all-rounder

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

Embedded & Industrial PCs International Products and Configurations INDEX

sontheim Wir leben Elektronik! We live electronics! Industrie Elektronik GmbH Computer-on-Modules Overview of our Computer-on-Modules

Data Sheet Fujitsu ESPRIMO P2440 Desktop PC

HQP-1072 Series System User Guide

Product name: D 6100XA EAN bar code: Shuttle order code: PIC-DS61011

Ampro by ADLINK Computer Systems

Versatile Applications

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Quick Start Turning on the Tablet PC for the First Time

PPC-5152-D525. Applications. 1.3M Webcam and 3W Speaker. 15 Flat-bezel Industrial Panel PC. Combo Gigabit LAN. 19

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

Three-phase monitoring relay CM-PFE

Data Sheet FUJITSU Thin Client FUTRO A300

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Cisco MCS 7825-H2 Unified CallManager Appliance

Rugged and open to your applications

How To Use A Powerline Powerline 2.5D (Powerline) With A Power Supply (Power Supply) And Power Supply Power Supply From A Powerplant (Powerplant) With An Industrial Pc (Powerboard) With Power

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

LwLVision-USB 2.0. Installation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Ingenico. User Guide 5100M. Secure transaction and payment solutions

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

US Installation Manual Smappee Monitor

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Telephone- and leased line modem for industrial applications TD-36

AFL-15i-HM55/AFL-17i-HM55/AFL-19i-HM ~19 AFOLUX PPC features Intel Core i7/i5/i3 processor with HM55 chipset

My first Hirschmann: The SPIDER family of switches.

MCR1900 Media Converter 19-Slot Chassis

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rack mounted telephone- and leased line modem for industrial applications

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Ensto Chago Master EVM300 and EVM500 Operational description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

AXIS 291 1U Video Server Rack Installation Guide

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Transcription:

ipc10 ipc20 Operating Instruction isel Germany AG, D-36124 Eichenzell, Bürgermeister-Ebert-Str. 40 (06659)981-0 (06659)981-776

The information, technical data and dimensions contained in this print have been up-to-date when published. Any eventually existing misprints and mistakes cannot be excluded however. We are thankful for any suggestion for improvement and indication of mistakes. Please note that the used software- and hardware descriptions of each individual company are generally subject to protection of trademarks and patent law. All rights reserved. It is not permitted to reproduce or electronically process, duplicate or spread any part of our prints in any way (print, copy etc.) without written permission of isel Germany AG. Manufacturer: isel Germany AG Bürgermeister-Ebert-Straße 40 D-36124 Eichenzell Tel.: (06659) 981-0 Fax: (06659) 981-776 Email: automation@isel.com http://www.isel.com Status: 02/2009 CB

Table of contents 1 Introduction... 1 1.1 Safety symbols... 1 1.2 Sicherheitshinweise... 1 2 Product description... 2 2.1 Technical data... 2 2.2 Connectors / Interfaces ipc10, ipc20... 3 3 Mounting and operation... 4 3.1 Mounting dimensions... 4 3.2 Mounting... 5 3.3 Switch on ipc10/ipc20... 5 4 Maintenance and cleaning... 6 5 EC Declaration of Conformity... 7

1 Introduction 1.1 Safety symbols Attention This symbol signalizes that there is danger for peoples life und health. Danger This symbol signalizes that there is danger for material, machine and environment. Information This symbol signalizes important information. 1.2 Sicherheitshinweise The Control PC series ipc are designed to current technical and recognized rules. The device may only be used if it is in correct condition. Any faults have to be eliminated immediately. Neither children nor non-authorized persons are allowed to put the device into operation. The device may only be used for the intended use. All work on the module must be executed from authorized personal regarding electrical industry rules and accident prevention regulations. Assembly and use of operating material has to be according to the standards of conformity declaration. In case of in proper use even the observation the respective rules and standards does not protect against physical damages and damage to property. Do not expose the device to high humidity or high vibrations. Please take care of the instruction manual. Be sure that all users know the instructions. Ignoring the instruction manual can lead to damage, heavy physical damage or to death. Page - 1

2 Product description 2.1 Technical data ipc10 ipc20 dimensions (L x H x W): 190 x 52 x 200 mm 190 x 52 x 200 mm weight: 1,1 kg 1,1 kg ambient temperature: 0 C bis 55 C humidity: max. 90% not condensing safety class: IP20 power supply voltage: 12 VDC/ min. 60W 12 VDC/min. 60W intended use: Industrial area / home- office area Industrial area / home- office area form factor: Mini-ITX Mini-ITX CPU: Intel ATOM 230 1,6 GHz Intel ATOM 330 2 x 1,6 GHz, DualCore memory (RAM): DDR2-RAM 1GB DDR2-RAM 1GB hard disk: 2,5 HDD 160GB, SATA 2,5 HDD 160GB, SATA power supply(optional): external power supply 12V/ 60W external power supply 12V/ 60W operating system: Windows XP, Windows Vista Windows XP, Windows Vista connectors: 1 x VGA (On Board) 2 x PS2 (Maus, Tastatur) 4 x USB 2.0 1 x LAN 10/100MBit 1 x COM, RS232 1 x LPT 1 x RCA/SPDIF, Audio 1 x VGA (On Board) 2 x PS2 (Maus, Tastatur) 4 x USB 2.0 1 x LAN 1GBit 1 x COM, RS232 1 x LPT 1 x RCA/SPDIF, Audio 1 x S-Video Page - 2

2.2 Connectors / Interfaces ipc10, ipc20 No. Connector / Interface 1 PS/2 Mouse Connector for PS/2 Mouse 2 PS/2 keyboard Connector for PS/2 keyboard 3 Serial Interface COM1 Connector for a serial interface, type RS232 4 VGA Connector 15-pin VGA monitor 5 LAN 1x RJ45 connector for Ethernet network 6 USB-Schnittstellen 4 x USB 2.0 Schnittstellen für den Anschluss von Peripheriegeräten 7 USB-Slots 4 x USB 2.0 Interface slots to connect peripheral USB devices 8 S-Video (only ipc20) S-Video connector output 9 LPT connector SubD25-pin socket, printer port 10 PC-Start button Switch On/Off ipc, green lighting signalizes powered state of the computer 11 Socket for external power supply unit min. 12 VDC/60W power supply voltage Page - 3

3 Mounting and operation 3.1 Mounting dimensions Dimension drawing ipc10 Dimension drawing ipc20 Page - 4

3.2 Mounting For mounting the ipc10/ipc20 use the mounting holes on the cover plate. Using ipc10 or ipc20 with isel 22 TFT display When using the ipc10/ipc20 with a isel 22 TFT display the mounting is done by a rack mount on the back side of the TFT display. Note that there is enough free zone on the louvers for air circulation. Ignoring this fact causes overheat and potential defect of the ipc Please avoid extreme environment conditions. Protect the control PC for dust, humidity and heat. Do not cover the louvers!! 3.3 Switch on ipc10/ipc20 Switch on ipc10/ipc20 by pressing the PC-start button on the front side of the computer. (see also Chapter: 2.2). If ipc10/ipc20 is witched on the PC-start button is green lighted. Page - 5

4 Maintenance and cleaning Maintenance The computer ipc10/ipc20 are maintenance free. Cleaning Switch off ipc10/ipc20 and all connected components. Remove the power supply voltage connection. Use a wet, soft cloth to clean the case. Don t use cleaning agents or abrasives. Be sure that no moisture comes into the case. Page - 6

5 EC Declaration of Conformity EC - Declaration of Conformity Der Hersteller The manufacturer isel Germany AG Bürgermeister-Ebert-Str. 40 D-36124 Eichenzell erklärt hiermit, dass folgendes Produkt hereby declares that the following product Geräteart: Device: Typ: Type: Industrie PC industrial PC ipc10, ipc20 Art.-Nr.: ipc10: 371065 ipc20: 371063 Product - No.: mit den Vorschriften folgender Europäischer Richtlinien übereinstimmt: complies with the requirements of the European Directives: EG-Richtlinie 2004/108/EG EC-Directive 2004/108/EC EG-Richtlinie 73/23/EWG EC-Directive 73/23/ECC EMV Richtlinie EMC directive Niederspannungsrichtlinie low voltage directive Folgende harmonisierte Normen wurden angewandt: Following harmonized standards have been applied: EN 61000-6-2:2005 EN 61000-4-2:2007 EN 61000-4-4:2004 EN 61000-4-5:2006 EMV - Fachgrundnorm - Störfestigkeit für Industriebereich EMC - Generic standards - Immunity for industrial environments EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Entladung statischer Elektrizität (ESD) EMC - Testing and measurement techniques; Electrostatic discharge immunity test EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgrößen (Burst) EMC - Testing and measurement techniques - Electrical fast transient/burst immunity test EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen energiereiche Impulse (Surge) EMC - Testing and measurement techniques - Surge immunity test EN 61000-4-11:2004 EN 61000-6-4:2007 EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Spannungseinbrüche / Spannungsunterbrechungen EMC - Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests EMV - Fachgrundnorm - Störaussendung Industriebereich EMC - Generic standards - Emission standard for industrial environments DIN EN 55011:2007 Industrielle, wissenschaftliche und medizinische Hochfrequenzgeräte (ISM-Geräte) - Funkstörungen - Grenzwerte und Messverfahren Industrial scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement Dermbach, 13.01.2009 Hugo Isert, Vorstandsvorsitzender / chairman Page - 7