Wolflite Safety Handlamp H-251E



Similar documents
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Instructions for Safe Use

Operating Instructions

Bulb Replacement REPLACING BULBS WARNING

7 Lighting Technology

Floodlight Range Installation Guide

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Operating Instructions

Quick start guide smart.power smart.power smart.power

Operating Instructions Bedienungsanleitung Mode d emploi

ST Series POWER SUPPLIES USER INSTRUCTIONS

Technical Data. Dimensions

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

Mobile Data Power Model: MDP-25

3 WATT LED SPOTLIGHT Model No. SLM

National- Spencer Inc.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

PROFESSIONAL PRODUCTS- PET NAIL GROOMERS

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

How To Use A Power Supply Unit (Upu)

TIG INVERTER INSTRUCTION MANUAL

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Linear Luminaire with LED Series EXLUX 6402/2

OWNER S MANUAL AND WARRANTY INFORMATION

V94 BULK TAPE DEGAUSSER

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Safety instructions VEGADIS DIS81.CEIA/V****

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Acclaim III Recessed Fluorescent Luminaires ATEX

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

13 Watt PORTABLE SOLAR POWER KIT

Stove Guard Kit User Manual

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

Rousseau 10. User Guide

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

BT Big Button 100. User Guide

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

2013 VTech Printed in China US

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Mureva Assembly surface mounted wiring devices

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Plug and Socket Devices CES 63 A Series 8579

Product and functional description

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Installation and Operating Instructions (for chargers shown below)

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Height w/o Terminals (in)

BULB REPLACEMENT BROCHURE

SHOT BLAST CABINET MODEL NO: CSB20B

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Operating instructions Cordless K impact wrench

Rechargeable Spotlight

350, 500, 650 and 1000 MODELS

Technical data sheet TDS0070

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

Manual. Solar Fountain Mobile Phone Charger

Wiper Motor Marinco 2.5. Installation Instructions

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

User Manual for CH-PFC76810

ELECTRIC KNIFE SHARPENER

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Power your CPAP machine no matter where your world takes you!

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Table Of Contents

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Ingenico. User Guide 5100M. Secure transaction and payment solutions

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Drayton Digistat +2RF/+3RF

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

WIRELESS MAGNETIC CONTACT

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

Bedienungsanleitung Akku-Bohrschrauber Manual de Instrucciones Taladro atornillador a batería Manual de operação Aparafusadora com bateria

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

KEY TELEPHONE SYSTEMS RESERVE POWER 47C POWER UNIT

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

SECURITY SYSTEM SMART SIREN KIT

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

3000W Power Inverter

Transcription:

Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63 H 41E

Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251 Mk2 H 18 H 17 H 31 H 08 H 15E H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 22 H 23 H 29 H 16E H 13 H 40E H 14 H 09 H 12 H 10 H 11 H 38E H 39E H 36E H 37E H 41E

Wolflite H-251 Rechargeable Safety Handlamp Range Certification H-251E EEx e ib IIC T4 Certificate: BASEEFA Ex 843292 H-251 Mk1 & Mk2 EEx e s II T3 Certificate: BASEEFA Ex 81142 Certificate: 86/00097 Use of Wolflite Handlamps in Hazardous Areas The H-251E Handlamp is certified for use in potentially explosive gases, vapours and mists. Applicable standards: EN50014:1977, EN50019:1977, EN50020:1977. The H-251 Mk1/Mk2 Handlamps are certified for use in potentially explosive gases and vapours. Applicable standards: EN50014:1977, EN50019:1977, SFA 3009:1972. Ingress protection level for H-251E and H-251 Mk1: IP66, to EN60529:1992 for H-251 Mk2: IP54 to EN60529:1992. Users are advised to consult BS 5345: Part 1:1989 Code of Practice for the Selection, Installation and Maintenance of Electrical Apparatus for use in Potentially Explosive Atmospheres or National equivalent. The lamp must not be opened or fitted with replacement parts in a hazardous area. Lamp chargers must be kept and operated in non hazardous areas and in clean and dry conditions; a damaged lamp should be carefully examined for its continued safety. If in doubt, it should be withdrawn from use and returned to the manufacturer for repair. The Wolflite Handlamp may constitute a static hazard and should be cleaned only with a damp cloth. Heavily soiled lamps must not be immersed in water or exposed to high pressure water jets for cleaning. Maintenance and repair must be carried out by a competent technician/electrician familiar with Certified Electrical Apparatus and in accordance with these maintenance instructions, using factory supplied spare parts only. Handlamp operating ambient in Hazardous Areas: -20 C to +40 C Before Use Charge battery before first use. To prevent accidental discharge of the battery in transit, the switch is locked in the OFF position. To Lock/Unlock the Lamp (H-251 Mk1 & Mk2 only) The stainless steel lock screw in front of the handle interlocks with the operating switch. Screw anti-clockwise to lock the lamp enclosure and release the operating switch. The lock key provided must be kept in a non-hazardous area. WARNING: The Lock Screw bush can be dislodged if overtightened. Switch OFF before screwing the Lock Screw down. To Operate and Dismantle the Switch The switch operates transversely, as indicated on the approval label. It consists of a magnet, a plastic housing and a cap. To replace, the old cap is prised off and the housing removed. The new switch housing/magnet is fitted to the body before the cap is snapped in place. To Open the Lamp Unlock as above, unscrew the lens ring from the body to gain access to all internal parts. To Replace the Bulb The bulb (3.6 Volts, 1.0 Amp) is retained by the screwed centre contact at the back of the reflector. To Replace the Glass Disc and/or Reflector The toughened glass disc and reflector are secured in the lens ring by the reflector retaining ring. The battery retainer (H-251 MkI/ Mk2 only) is snap fitted in the lens ring, remove before unscrewing the reflector retaining ring. All parts must be cleaned and the rubber washer centralised before re-assembly. A key is available for fastening/unfastening this assembly. To Replace Fuse and/or Reed Switch The fuse contact must be removed to replace the fuse (Shorting Link in H-251E). To replace the reed switch, the battery contact and fuse contact must be removed. To Replace the Battery for the H-251 Mk2 The positive and negative diode leads are disconnected from their respective terminals and the battery pack is removed from the body cavity. To Replace the Battery for the H-251E All connections are automatically made when the H-251E battery pack is replaced. The battery pack is a slide fit in the body cavity, clean the new battery pack and spring contacts prior to fitting. The H-251E battery pack is deep discharge protected, it will switch off after approximately four hours duration, preventing damage to the battery.

The Battery A Lead Acid cell system is used in all Wolflite Safety Handlamps. A minimum of four hours continuous output is provided for an average of 500 recharging cycles. A common battery pack is used for the H-251 Mk1 and H-251 Mk2. The H-251E battery pack has an encapsulated control and current limiting circuit, and has been tested for EMC compliance and CE marked accordingly. For optimum performance and safety please observe the following: Charge before first use. Note: Dangerous Goods Regulations Avoid deep discharge. Hazardous Materials Regulations Recharge immediately when flat. Restricted Articles Regulations Recharge every six months when stored. The US Dept. of Transport, IATA, and CAA declare these batteries are not regulated. Warning: Do not short-circuit or incinerate Do not cut, crush or puncture Do not recharge other than from Wolf Chargers Dispose of only via licensed disposal agency Charging Wolflite H-251 Mk1 Battery To remove the battery for charging remove the lens ring (see To Open the Lamp ). The battery removal tab is visible and can be used to aid extraction. WHILE THE BATTERY IS ON CHARGE THE LENS RING MUST BE REPLACED TO PREVENT DUST ENTERING THE LAMP ENCLOSURE. If available, a spare charged battery can be fitted. The Battery is charged in a fully automatic charging unit. Indicators show when a battery has been fully charged. AFTER USE, RE-CHARGE AS SOON AS POSSIBLE. Charger Unit C-251 for H-251 Mk1 This Wolflite Battery Charger is CE marked as compliant with Low Voltage and EMC Directives. Before connecting to the mains ensure the correct voltage is selected and the battery is in the charger, the indicators will show the state of battery charge and charger mode. 90% capacity is achieved in 4/5 hours. The charger indicators will suffer from electro-magnetic interference when sited less than five metres from sources emitting at the following frequencies: 103-115MHz, 117-119MHz, 126-136MHz. Charging Wolflite Handlamps H-251 Mk2 and H-251E The battery is charged within the lamp body. The H-251 Mk2 Handlamp switch must be in the OFF position when on charge. The H-251E can be switched ON when charging, the lamp is then set for stand-by power failure mode and will automatically illuminate should power to the charger be cut. Indicators show the state of charge of the battery. Red only indicates the Lamp has not made correct contact, the Lamp must be pushed firmly until latched in position. Lamp Chargers for H-251 Mk2 and H-251E Two types of Lamp Chargers are available HIGH VOLTAGE and LOW VOLTAGE, to suit fixed or mobile applications. The chargers are CE marked as compliant with Low Voltage and EMC Directives. Wolflite Charger C-251HV is for mains AC input voltages of 200-240 volts at 50-60 Hz (Off-shore platform voltages of 254 volts at 60 Hz), user switchable to 100-120 volts at 50-60 Hz. Failure to select the correct voltage may cause damage. Charger achieves 90% recharge in 6/7 hours. Only fit manufacturer s specified fuse. Chargers are fitted with Approved plugs, refer to sales literature for details. Wolflite Charger C-251LV is suitable for use from DC supplies of 12 to 32 volts. A full recharge from a 12 volt supply takes 20/24 hours, but from a 24 volt supply 10/12 hours. The two-core flex is red, positive and black, negative. Both chargers are fully automatic, stepping to a safe trickle charge level after the main charge is completed. NOTE: A fully discharged battery must be charged immediately to avoid damage. The charger contacts are of low voltage output and short circuit protected. Charger operating ambient: +10 C to +25 C. WARNING: THE WOLFLITE CHARGERS ARE DESIGNED FOR CHARGING WOLFLITE HANDLAMPS ONLY NO OTHER BATTERIES OR BATTERY OPERATED DEVICES ARE TO BE USED The Wolf Safety Lamp Co. Ltd. have a policy of continuous product review and improvement, and changes in design details whether permitted as Variations of Approvals or otherwise may be made without prior notice.

Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251 Mk1 H 18 H 17 H 31 H 08 H 15 H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 22 H 02 H 23 H 29 H 16E H 13 H 14 H 09 H 12 H 10 H 11

Spare Parts List for Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Description H-251 Mk1 H-251 Mk2 H-251E O ring seal H-02 H-104 Magnet switch complete H-03 H-03 H-03 Lock screw H-08 H-08 H-08 Reed switch H-09 H-09 H-09 Fuse for lamp, & link (H-251E) H-10 H-10 H-48 Sleeve for fuse holder H-11 H-11 H-11 Fuse contact H-12 H-12 H-12 Battery contact H-13 H-13 H-13 Screw for contacts H-14 H-14 H-14 Body complete H-15 H-15E H-15Y Battery pack H-16E H-16E H-66 Lens ring H-17 H-17 H-17 Rubber washer for glass disc H-18 H-18 H-18Y Glass disc H-19 H-19 H-19 Reflector H-21A H-21A H-21A Reflector retaining ring H-22 H-22 H-22 Battery retainer H-23 H-23 Reflector distance piece H-24 H-24 H-24 Bulb socket H-25 H-25 H-25 Bulb 3.6v 1.0A Krypton (4 hrs.) H-26 H-26 H-26 Bulb 4.8v 0.5A Krypton (8 hrs.) H-26K H-26K H-26K Centre contact complete H-29 H-29 H-29 Reflector c/w bulb and fittings H-30 H-30 H-30 Lens ring complete H-31 H-31 H-31Y Hexagon lock key 4 mm H-33 H-33 H-33 Key for reflector retaining ring H-34 H-34 H-34 Lanyard and fittings H-35 H-35 H-35B Nut for contact stud H-36E H-62 Spring washer for nut H-37E Diode lead (positive) H-38E Diode lead (negative) H-39E Terminal tab H-40E Support washer H-41E H-41E Handlamp wall holder H-58 H-58 H-58 Stud seal H-63 C-251 C-251HV C-251LV Clip for LV charger C-57 Rocker switch for charger C-62 Transformer 9V, 20VA C-63 Printed circuit board C-69 Lamp charger contacts C-71 C-71 PCB for LV DC charger C-81 Rocker switch for HV charger C-82 PCB for HV charger C-84 Washer for clip T-2056 Rivet for clip T-2057 Support spring C-6021 C-6021 Fuse for charger H-10 H-10 WOLF SAFETY LAMP COMPANY Saxon Road Works, Sheffield S8 0YA, England Tel: +44 114 255 1051 Fax: +44 114 255 7988 E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk MMD/U/?K/6.03