Configuring Alarms & Relays in the Enhanced Transformer Advantage



Similar documents
Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

T-100-R Installation Guide

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Controller Automation, Model II+

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

*.ppt 11/2/ :48 PM 1

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

A1000 Cheat Sheet (Open Loop Vector)

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Application Engineering

, User s Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Ammonia Detection System Codes and Design Specifications

HEAT HEAT COOL HEAT PUMP COOL

HERZ-Thermal Actuators

Technical Information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

Programmer/Controller


Thermostat with display

535T Window Automation System

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

WD-AMX Water Detection Controllers

IO-RM3 3-Stage Relay Module

Alarms Trips: The Ups and Downs

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Conventional Fire Detection and Extinguishant Control System Specification

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

TECHNICAL BULLETIN. Wiring Diagrams. TPI Wiring. TB Rev. March 4, 2013 Page 1 of 5. Switch Settings 3 PHASE POWER SUPPLY 3 PHASE POWER SUPPLY

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Multi-Range Programmable DC Power Supplies 9115 Series

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Thermistor motor protection

MicroTech III Unit Controller for Water Source Heat Pump Units

Safety Requirements Specification Guideline

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

NC-12 Modbus Application

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

Nest Learning Thermostat Pro installation & configuration guide

Operational Overview and Controls Guide

GTEC transfer switch open transition

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Simplify Data Acquisition with a Built-in LXI Web Server

MicroTech III Unit Controller for Water Source Heat Pump Units

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

INTREPID Perimeter Intrusion Detection System

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Perimeter Security System

Designed for multi-injector endurance testing, the

Car Alarm Series 2 B 2 Buttons

SMS GSM Alarm Messenger

MSL1000 Monitored Serial Link Interface Manual V1.01

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Inwall Room Temperature Unit

INSTALLATION AND OPERATION MANUAL

Installation Instructions

VLT 6000 HVAC. Contents

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Memcom Emergency Telephone

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Install Guide CT101. Caution. Caution

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Mode Switch. Fan Switch Menu button Program button

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Problem / Solution. The problem:

How To Control A Car Alarm On A Car With A Remote Control System

Solid State Timers Type F

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

Variable Air Volume - VAV

HM-W536 Install Guide

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

1 For All Non-Programmable Digital Thermostat

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

NOTE. BASautomation AN-BASREM00-BA0. Redundant Sump Pump Controller. Redundant Sump Pump Controller. Sequence of Operation. Introduction.

Specifying a Variable Frequency Drive s

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

210E - 210ECL ECL ECL RMS Signal Monitor. Operations Manual

Trouble Shooting Guide

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

LC/LCD ranges level controllers

Transcription:

Configuring s & Relays in the Enhanced Transformer Advantage The Transformer Advantage product family offers a variety of relay options. Some choices are made when the Advantage is specified and ordered. Other choices are made during installation and setup. The following information will help make the best use of this flexibility. Relay terminology used in the Transformer Advantage documentation: Form A contact: normally open (NO) when power to the Advantage is off. Form B contact: normally closed (NC) when power to the Advantage is off. Form C, also called a changeover contact, provides both form A & form B contacts. Normally (NE) or Normally De-energized (ND) refers to the relay coil state when the Advantage is powered and the relay is in the non-alarmed condition. Setpoint relays are used for control and alarm outputs. Up to form C relays can be ordered by selecting the appropriate code in the fourth digit of the part number. All relays in the Transformer Advantage are single pole. The contacts are rated for A (/2HP) @25Vac or A @25Vdc and include AC transient protection. For higher loads or longer relay life, an interposing relay should be used. The alarm conditions for each setpoint relay are defined at setup. More than one alarm can be linked to a relay. 24 alarms are available in the Advantage, regardless of the number of relays ordered. This allows complex control with minimal wiring. The alarm condition for temperature and current inputs is a signal value ABOVE the setpoint. Setpoint relay contact state: Setpoint Relay configured Normally Below Setpoint Above Setpoint NC closed closed open NO open open closed Setpoint Relay configured Normally Below Setpoint Above Setpoint NC closed open closed NO open closed open Relay Appl Enhanced, pg

The Advantage automatically runs periodic sensor and internal self checks. In addition to the setpoint relays, each Advantage includes an extra relay for a sensor fail (watchdog) function. When a fault is detected, the Sensor Fail Relay (SFR) changes from a normal to an alarm state. Relay 6 is typically setup as the SFR, although any relay can be used. For redundancy in critical applications, more than one relay can be assigned to this function. Each setpoint relay will respond to a sensor or internal failure as determined by two configuration variables: Sensor Fail Response (SNFAL) and Sensor Fail Effect (SNEFF). When SNFAL is enabled, the setpoint relay will respond in the manner defined by SNEFF. SNEFF choices are energize (EN), de-energize (DE) or toggle. Setpoint Relay configured Normally, SNEFF on Sense Fail Below SP Above SP SNFAL DE SNFAL EN NC closed closed open closed open NO open open closed open closed Setpoint Relay configured Normally, SNEFF on Sense Fail Below SP Above SP SNFAL DE SNFAL EN NC closed open closed closed open NO open closed open open closed Setpoint relays can also be configured to allow a serviceman to test relay operation in the field. Once this feature is enabled on a relay, testing can be done from the front panel or with a laptop using the supplied Advantage Monitoring software. Relays installed in the Enhanced Transformer Advantage: AMT22 AMT2 & prior Relay Option Code D, 2, 6, 2, 8 E, 2, 3, 4, 6, 2, 3, 4, 8 H - 6 ---- F - 4, 6- -4, 8, 9-2 L - 2 ---- Miscellaneous Option V ---- 7 The following examples are intended to show some of the features available for relays & alarms in the Transformer Advantage. Contact Weschler's factory support specialists for assistance in configuring a Transformer Advantage for your application. Relay Appl Enhanced, pg 2

Example : Set the Advantage to control two fan banks in a failsafe configuration, plus two external alarms. Use a separate service alert to warn of a sensor fail, self-test fail or power loss to the Advantage. L L2 7 C Winding Close above Setpoint R NE M Fan Bank 9 C Winding Close above Setpoint R2 NE M Fan Bank 2 C Winding Close Above Setpoint R3 ND Over Temp Alert 5 C Winding Close Above Setpoint R4 ND Over Temp Close on Sensor Fail or Self-test Fail R6 NE contact power off state shown; interposing relay not shown. Service Alert ND = Normal (non-alarm) coil de-energized NE = Normal (non-alarm) coil energized To implement, wire as shown above. Configure 2 relays for cooling fans and 3 relays for external alarms. Define the normal (non-alarmed) coil state for standard or fail-safe mode. Then set up the internal alarms for setpoint, hysteresis & delay. Link each alarm to a relay. Enable sensor failure response & effect for the alarms tied to fan stages. PARAMETERS: CONNECTED NORMAL COIL SENSOR FAILURE # EQUIPMENT STATUS CHECK SEQUENCING EFFECT 2 OF OF 3 4 5 6 ALARM SOURCE SETPOINT HYST. PICKUP DROPOUT OPERATE ALARM SEASOL SENSOR # (secs) (secs) # TRIGGER SETBACK FAILURE Winding Temp 7. ºC 3. ºC 5 2 Winding Temp 75. ºC 3. ºC 5 2 3 Winding Temp. ºC. ºC 3 4 Winding Temp 5. ºC. ºC 4 5 6 Sensor Failure 6 Notes: Five setpoint relays ordered (option H). Relay 5 is not used, available as a spare. to alarm:relay association used for convenience. Relay check disabled on the over temperature alarm and the sensor fail relay. Pickup delay applied to reduce rapid cycling and transients. Relay Appl Enhanced, pg 3

Enhancement : Add cooling and external alarm activation based on top oil temperature. Set Fan Stage to operate at 7 oil; set Over Temperature for 95 oil. To implement, enable additional internal alarms and program for the desired top oil temperatures. No change to relay setup needed. ALARM SOURCE SETPOINT HYST. PICKUP DROPOUT OPERATE ALARM SEASOL SENSOR # (secs) (secs) # TRIGGER SETBACK FAILURE Winding Temp 7. ºC 3. ºC 5 2 Winding Temp 75. ºC 3. ºC 5 2 3 Winding Temp. ºC. ºC 3 4 Winding Temp 5. ºC. ºC 4 5 6 Sensor Failure 6 7 Top Oil Temp 55. ºC 3. ºC 5 8 Top Oil Temp 95. ºC. ºC 4 9 Enhancement 2: Add a pre-cooling function to anticipate the temperature rise from heavy transformer loading. To implement, program an unused alarm for a winding current setpoint and have it activate the fan relay. ALARM SOURCE SETPOINT HYST. PICKUP DROPOUT OPERATE ALARM SEASOL SENSOR # (secs) (secs) # TRIGGER SETBACK FAILURE Winding Temp 7. ºC 3. ºC 5 2 Winding Temp 75. ºC 3. ºC 5 2 3 Winding Temp. ºC. ºC 3 4 Winding Temp 5. ºC. ºC 4 5 6 Sensor Failure 6 7 Top Oil Temp 55. ºC 3. ºC 5 8 Top Oil Temp 95. ºC. ºC 4 9 Winding Current 3 A 5 A 3 Enhancement 3: Add daily fan exercise to each fan bank. To implement, set up the daily system time trigger and enable that trigger for alarm and alarm 2. ALARM TIME and SEASOL SETBACK PARAMETERS: TYPE START DATE START TIME STOP DATE STOP TIME Daily Weekly / 3: 2/3 3:5 Monthly ALARM SOURCE # SETPOINT HYST. PICKUP DROPOUT OPERATE ALARM SEASOL (secs) (secs) # TRIGGER SETBACK SENSOR FAILURE Winding Temp 7. ºC 3. ºC 5 Daily 2 3 Winding Temp Winding Temp 75. ºC 3. ºC. ºC. ºC 5 2 3 Daily 4 5 Winding Temp 5. ºC. ºC 4 6 7 Sensor Failure Top Oil Temp 55. ºC 3. ºC 5 6 8 9 Top Oil Temp 95. ºC Winding Current 3 A. ºC 5 A 3 4 Relay Appl Enhanced, pg 4

Enhancement 4: Run fan bank continuously in the summer. To implement, set up the calendar time trigger. Add calendar activation for alarm. ALARM TIME and SEASOL SETBACK PARAMETERS: TYPE START DATE START TIME STOP DATE STOP TIME Daily / 3: 2/3 3:5 Weekly Monthly Calendar 6/ 8: 9/5 2: ALARM SOURCE SETPOINT HYST. PICKUP DROPOUT OPERATE ALARM SEASOL SENSOR # (secs) (secs) # TRIGGER SETBACK FAILURE Winding Temp 7. ºC 3. ºC 5 DC 2 Winding Temp 75. ºC 3. ºC 5 2 Daily 3 Winding Temp. ºC. ºC 3 4 Winding Temp 5. ºC. ºC 4 5 6 Sensor Failure 6 7 Top Oil Temp 55. ºC 3. ºC 5 8 Top Oil Temp 95. ºC. ºC 4 9 Winding Current 3 A 5 A 3 For multiple ALARM TRIGGER: D->Daily, W->Weekly, M->Monthly and C->Calendar Enhancement 5: Activate a relay when an auxiliary input signal exceeds a threshold level. * To implement, set the channel jumpers on the LCAM module to the correct function & range. In the software, set up the auxiliary input (LCAM) channel for the input signal type and full scale value. In addition to the 24 setpoint alarms in the Transformer Advantage, each LCAM channel has one alarm available. Set the high and low thresholds (LCAM alarms have dual limits - alarm condition occurs when signal goes outside these limits). Program it to operate an unused relay (#5 in this example) and configure the relay as an alarm. LCAM ALARM INPUT THRESHOLD THRESHOLD HYST. ASSOC. PICKUP DROPOUT OPERATE ALARM # SCALE LOW HIGH # (secs) (secs) # TRIGGER 2 2.mA DC 4.mA DC 5.mA DC.mA DC 5 PARAMETERS: # CONNECTED EQUIPMENT NORMAL COIL STATUS CHECK SEQUENCING SENSOR FAILURE EFFECT OF 2 3 OF 4 5 6 * Requires optional auxiliary analog/digital input. For this example, the Advantage receives a 4-2mA signal from a DG analyzer or an LTC position monitor. Low threshold can be used to detect an out-of-bounds condition or an open input. Relay Appl Enhanced, pg 5

Enhancement 6: Use current readback to confirm operation of a cooling stage. This enhancement requires an optional analog/digital input and a compatible Weschler current transducer. To implement, clamp the current transducer (CT) around the cooling stage supply wire. Connect the CT leads to an auxiliary input on the LCAM module. Set the LCAM channel jumpers to the 5V range. In the software, set the input scale on the corresponding LCAM alarm to the transducer full scale rating. Select the high and low thresholds to detect improper operation (such as locked rotor or blown fuse). Associate this channel to the cooling stage being monitored (so the alarm is enabled only when the cooling stage should be on). Add a pickup delay to prevent false alarms due to motor starting current. For a 5A transducer monitoring fan stage and connected to LCAM channel 3: LCAM ALARM INPUT THRESHOLD THRESHOLD HYST. ASSOC. PICKUP DROPOUT OPERATE ALARM # SCALE LOW HIGH # (secs) (secs) # TRIGGER 2 2.mA DC 4.mA DC 5.mA DC.mA DC 5 3 5.A AC 25.A AC 62.A AC 5.A AC Cooling stage readback also allows the Advantage to apply the correct gradient when a cooling stage is activated external to the Advantage (e.g. by a manual switch). As programmed above, this LCAM alarm is available on the SCADA digital output. It can also be set up to operate a relay by selecting one in the Operate Relay # field. This can be an unused relay, if available, or an additional alarm condition for a relay already in use (e.g. relay 3 in this example). Enhancement 7: Equalize running time between multiple cooling stages. For equalization of run time between 2 or more fan stages, a sequencing function can be enabled. Similarly, if there is more than one pump stage, sequencing can be enabled to equalize the run time of the pumps. To implement, enable sequencing in the relay setup for fan or pump stages. A run time counter in the Advantage tracks operating hours for each stage. At the next call for fan cooling, the fan stage with the fewest hours will turn on. PARAMETERS: # CONNECTED EQUIPMENT NORMAL COIL STATUS CHECK SEQUENCING SENSOR FAILURE EFFECT OF 2 3 OF 4 5 6 General Note: Configuration files have a.txt extension and can be viewed with a text editor (as shown in these examples). To construct a file or make changes, the Configuration app in the Weschler Advantage Software must be used. This software is supplied with each unit and is also available from the Weschler website. Relay Appl Enhanced, pg 6 WT-4 /3/2