Keysight Technologies M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module

Similar documents
Agilent M9018A. Challenge the Boundaries of Test Agilent Modular Products. Data Sheet. PXIe Chassis 18-slots, 3U, 8GB/s

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

AXIe: AdvancedTCA Extensions for Instrumentation and Test

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

PXI Express Chassis with Integrated MXI-Express Remote Controller

Agilent E5063A ENA Series Network Analyzer

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

PXI and AXIe Modular Instrumentation

PXI and AXIe Modular Instrumentation

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

EMX-2500 DATA SHEET FEATURES GIGABIT ETHERNET REMOTE CONTROLLER FOR PXI EXPRESS MAINFRAMES SYSTEM LEVEL FUNCTIONALITY

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent 87421A/87422A Power Supply

Keysight U5309A PCIe High-Speed Digitizer with On-Board Processing

Cisco 7816-I5 Media Convergence Server

Agilent 4339B/4349B High Resistance Meters

1U µtca.4 Chassis with 2 AMC Slots, PCIe Gen 3 VT816

Enterprise Switches. Accelar 8000

Agilent 4338B Milliohm Meter

How To Build A Cisco Uniden Computing System

Cisco Unified IP Phone Power Injector

Application Server V240 Platform

Keysight U5309A PCIe High-Speed Digitizer with On-Board Processing

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent M9703A AXIe Digitizer

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

The Next Generation in Automated Oscilloscope Test

Scout 1U Rackmount Computer

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Agilent U2000 Series USB Power Sensors

Make Better RMS Measurements with Your DMM

PCI Express 1.0 (2.5 GT/s) Protocol Test

Keysight Technologies AC6800 Series Basic AC Power Sources. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

CompactRIO crio-9052

Keysight N6854A Geolocation System. Configuration Guide

Agilent P940xA/C Solid State PIN Diode Switches

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

MCR1900 Media Converter 19-Slot Chassis

Agilent U4301A PCI Express 3.0 Analyzer Module. Data Sheet. Agilent solutions for PCIe Gen1 to Gen3 analysis and emulation.

DATA SHEET. GigaStack GBIC THE CISCO SYSTEMS GIGASTACK GIGABIT INTERFACE CONVERTER (GBIC) IS A VERSATILE, LOW-COST,

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

R&S ZNC Vector Network Analyzer Specifications

Cisco MCS 7816-I3 Unified Communications Manager Appliance

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

DDR Memory Overview, Development Cycle, and Challenges

LaCie 12big Rack Network

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism

Multi-Range Programmable DC Power Supplies 9115 Series

COMPUTING AXP G AdvancedTCA Shelf. This six-slot, 40G ATCA shelf is ideal for both traditional telecom and enterprise environments.

Cisco Systems GigaStack Gigabit Interface Converter

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Agilent FieldFox Remote Viewer

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Agilent 8762/3/4A,B,C Coaxial Switches

AXIS T81B22 DC 30W Midspan

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

High Power Programmable DC Power Supplies PVS Series

HP Port Switches Quick Setup Guide

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TrueAlarm Fire Alarm Systems

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Chapter 5 Cubix XP4 Blade Server

Multi-Range Programmable DC Power Supplies 9115 Series

AXIS 291 1U Video Server Rack Installation Guide

HP Port and 48-Port Switches Quick Setup Guide

Cisco Redundant Power System 2300

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Cisco Nexus 7000 Series Power Supply Modules

802.11ac Power Measurement and Timing Analysis

power rid B ge C o m p u t e r

DVI DA2 and DVI DA 4 User Guide

Cisco TelePresence MSE 8000

1.44 kw Programmable DC Power Supplies XLN Series

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

R&S ZVA Vector Network Analyzer Specifications

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

WD Hard Drive Interface Guide

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Integrating PCI Express into the PXI Backplane

Cisco TelePresence MSE 8000

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Triple Expansion Chassis

Agilent U2000 Series USB Power Sensors

Evaluating Oscilloscope Bandwidths for Your Application

R&S ZNBT8 Vector Network Analyzer Specifications

Broadband Telecommunications Drop Amplifier

Transcription:

Keysight Technologies M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module Data Sheet

Introduction Product description The M9514A AXIe chassis and M9521A AXIe System Module (ASM) are fully compatible with the AXIe 1.0 and 2.0 specifications. The chassis provides 13 instrument modules slots plus an AXIe system slot while the ASM is used with the chassis to provide the necessary system functions. The ASM provides Gigabit LAN and Gen 2 x8 PCIe interfaces for connecting the chassis to an external controller. The chassis is designed to be easily maintained. The power supplies and fan trays can be removed while the chassis remains in the rack. Applications Aerospace and defense Computation Communications Electronics test Semiconductor testing High-energy physics Features AXIe 1.0 (architecture) and 2.0 (software) compliant Available AXIe System Module with Gen 2 PCIe x8 and Gigabit LAN interfaces for connecting to host computer Keysight Technologies, Inc. exclusive, built-in MultiFrame synchronization for multi-chassis systems 62 differential local bus lines provide very large data path between adjacent modules High power with 200W cooling per slot Front and rear removable fan trays Customer values AXIe chassis provides a high performance platform to compliment PXI based systems The 14-slot chassis can accommodate more AXIe modules when the application requires a larger system With the innovative cooling design, no additional rack space is required to meet cooling specifications while providing adequate cooling for a large number of high power modules The front panel x8 PCIe links on the ASM enable very large systems (up to three 14-slot AXIe chassis can be inter-connected) or allow AXIe and PXIe chassis to be combined in a single system

03 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet M9514A hardware overview Backplane configuration The AXIe backplane in the Keysight M9514A include all of the following AXIe backplane lines: Timing and triggering signals including: 100 MHz clock, 100 MHz PCIe clock (FCLK), point-to-point star trigger from the system slot (SYNC), bi-directional point-to-point star trigger (STRIG), and 12 signal parallel trigger bus (TRIG) Distributed PCIe data fabric (Gen 2 x4 to each slot) Distributed gigabit Ethernet LAN to each slot 62-pair local bus for adjacent module signaling or data transfer (AXIe only requires 18 pairs) DC power rail (nominally -52 VDC) Intelligent Platform Management Bus (IPMB) for chassis control, including module power-up Figure 1. 14-slot AXIe backplane in the M9514A. Figure 2. M9514A backplane block diagram.

04 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Chassis shelf manager The chassis shelf manager provides intelligent control of the M9514A including control of the chassis cooling fans and managing the chassis power-up sequence. This ensures there is sufficient power/cooling for each module. Innovative cooling The AXIe chassis utilizes a push-pull cooling design that provides a high volume of cooling air with acoustical emissions which are lower than a chassis with only a push or pull design. Fans in the front of the chassis bring in cool air from outside the rack and fans in the back of chassis pull the warm air out. Auto-speed fans are used to ensure adequate cooling as module temperatures change. Lower maintenance costs The chassis were designed to reduce maintenance costs. In addition, the power supplies, air filters, and fan trays can be removed while the chassis is mounted in a rack, allowing the chassis to be serviced while keeping DUT cabling in place. M9521A hardware overview The M9521A AXIe System Module (ASM) is installed in the system slot of the M9514A (slot 7). It provides the system communication and synchronization functions required in an AXIe chassis including: Trigger bus and clock routing Managing clocks, including internal or external reference sources Gigabit LAN switching with front panel RJ45 LAN connections (see module documentation to determine if a particular AXIe module is supported for LAN communications) AXIe Fabric 1 switching (Gen 2 x4 lanes to each module slot) Note: the M9521A is not compatible with the Keysight M9502A and M9505A AXIe chassis. Figure 4. M9521A AXIe system module (shown with shield removed). Figure 3. Rear view of M9514A AXIe chassis.

05 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet M9521A Hardware overview (continued) In addition to the required AXIe functions, the system module also provides: Ability to synchronize multiple chassis with trigger and clocking signals (MultiFrame In/Out connectors) Six multi-purpose, synchronization and triggering ports (SMB) External 10 MHz reference clock input/output (SMB) Dual Gen 2x8 PCIe in interfaces for connecting the chassis to an external computer and other chassis (including PXIe) Figure 5. M9521A ASM block diagram.

06 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Software platform Drivers The M9514A and M9521A chassis come complete with IVI- COM, IVI-C, and LabVIEW drivers. Windows 7 and 8.1 operating systems are supported and applications can be completed using many different software tools including LabVEW, LabWindows/ CVI, MATLAB, VEE, Visual Studio.NET (C/C++, C#, VB.NET). Soft front panel A soft front panel (SFP) interface is also provided to monitor and control the AXIe chassis and ASM. The chassis SFP provides monitoring for fans and temperature, a slot view, and chassis configuration/utilities. The SFP for the ASM includes configuration for triggering, I/O ports, system clocks, backplane sync, as well as system utilities including firmware upgrades and power-on states. The SFPs communicates to the chassis and ASM using IVI drivers. Chassis and ASM web servers Both chassis and ASM include a built-in web server for configuration, control, and monitoring. The web servers can be accessed by either LAN or PCIe. The M9514A chassis web page includes functions such as chassis information, LAN configuration, instrument module inventory, and chassis health (temperature, fan, power supply). The M9521A ASM web page provides ASM information, LAN and PCIe configuration, and firmware update capabilities. www.keysight.com/find/m9514a www.keysight.com/find/m9521a Figure 7. M9514A and M9521A web pages. Figure 6. M9514A and M9521A soft front panels.

07 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Technical Specifications And Characteristics M9514A chassis characteristics Standards compliance AXIe 1.0 Base Architecture Specification AdvancedTCA PICMG 3.0 R2.0 Specification Backplane Total slots 14 Instrument module slots 13 System module slot 1 Local bus lines 62 differential lines between each instrument module slot PCIe data fabric x4 Gen 2 to each module slot Mechanical Size 482.6 mm W x 589.7 mm H x 579.1 mm D 1 Weight (nom) 48.7 kg (107 lbs) 2 M9514A clocks and triggers 100 MHz system clock (CLK100) Maximum slot-to-slot skew: AXIe SYNC Maximum slot-to-slot skew: AXIe star trigger (STRIG) Maximum slot-to-slot skew: 100 ps 100 ps 20 ps 1. From front handle to IEC 60309 AC power connector, Top Cover to Rubber Feet 2. Without modules

08 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Technical Specifications And Characteristics (continued) M9514A power supply AC input Operating voltage range: Single phase or 3-phase delta 3-phase Wye 200-240 VAC 200/415 VAC Input frequency range: 50-60 Hz Input current: 24 Arms Overcurrent protection: auto recovery Efficiency (typical): 85-93% DC supply DC output 52 V Total DC module power: 2800 W Total maximum module current: 53.8 A Load regulation: 2% Max ripple and noise (20 MHzBW) 500 mv pk-pk Chassis cooling and power dissipation Slot airflow direction: Bottom to top Chassis cooling intake: Bottom-front of chassis Chassis cooling exhaust: Top-rear of chassis Chassis cooling fans: HIGH/AUTO speed selector Six 252.85 cfm fans in three front fan trays Ten 138.0 cfm fans in rear fan tray Power dissipation, instrument slot: 200 W maximum M9521A module characteristics Standards compliance: AXIe 1.0 and 2.0 specifications Module form factor: 1-slot AXIe Size 30.48 mm W x 350.9 mm H x 292.4 mm D Weight (nominal) 2.4 kg (5.3 lbs) Chassis slot compatibility: AXIe system module slot Front panel connectors: PCIe1 Upstream/downstream x8 Gen 2 PCIe2 Downstream x8 Gen 2 10 MHz REF clock IN/OUT SMB (2) MultiFrame 36-pin mini D (2) Port1-Port6 SMB (6) LAN 1/2 RJ45 (2) 10/100/1000 Base-T AXIe backplane I/O PCIe fabric x4 Gen 2 to each slot Ethernet 10/100/1000 Base-T to each slot Triggers TRIG [0:11] and STRIG Synchronization and control CLK100, SYNC, FCLK, IPMB 1. Not compatible with Keysight M9502A or M9505A AXIe chassis because these chassis do not have an AXIe compliant system slot.

09 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Technical Specifications And Characteristics (continued) M9521A DC power requirements DC current (max): Power dissipation (max): 2.6 A @ -52V (nominal) 135W M9521A clocks and triggers 100 MHz system clock (CLK100) Accuracy: ± 30 ppm Duty cycle 45/55% External REF clock in (SM) Input frequency: 10 MHz ± 100 ppm Input level: 5V pk-pk, AC coupled Minimum swing: 250mV Input impedance: 50 ohm External REF clock out (SMB) Output frequency: 10 MHz ± 30 ppm Output level: 3.3V, AC coupled Output impedance: 50 ohm Input/output ports (SMB) Direction control: Input, output, open-drain bi-directional (programmable) Number of ports: 6 Output level: 3.3V CMOS Output impedance (output mode): 50 ohm Output impedance (open-drain mode): 316 ohms pulled up to 3.3 volts Input level: ± 5V, programmable threshold Input impedance (input mode) 50 ohm or 3 kohm (programmable) Input impedance (open-drain mode) 3 kohm Minimum swing: 250 mv

10 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Technical Specifications And Characteristics (continued) 1, 2, 3 Environmental Operating and storage conditions Operating Storage Temperature: 0 C to 50 C -25 C to 60 C Altitude: Up to 10,000 ft (3048m) Up to 15,000 ft (4572m) Humidity: Type tested at 95%, +40 C (non-condensing) Vibration Operating random vibration: Type tested at 5 to 500 Hz, 0.21 g rms Survival random vibration: Type tested at 5 to 500 Hz, 2.09 g rms M9514A acoustical emissions (LWA db, ref 1pW) Maximum Nominal 4 Sound pressure 5 79 dba 67 dba Sound power 6 89 dba 77 dba 1. Characteristics apply to both M9514A and M9521A unless noted otherwise. 2. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of Storage, Transportation and End-use; those stresses include but are not limited to temperature, humidity, shock, vibration, altitude, and power line conditions. 3. Test methods are aligned with IEC 60069-2 and levels are similar ro MIL-PRF-28800F Class 3. 4. Empty chassis at 25 C ambient. 5. At operator position (LpA db, ref 20µPa). 6. LwA db, ref 1pW.

11 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Technical Specifications And Characteristics (continued) Regulatory 1 Safety Complies with European low voltage directive 2006/95/EC IEC/EN 61010-1, 2nd Edition Canada: CSA C22.2 No. 61010-1-04 USA: UL std no. 61010-1, 2nd Edition EMC Complies with European EMC drective 2004/108/EC IEC/EN 61326-1 CISPR Pub 11 Group 1, class A AS/NZS CISPR 11 ICES/NMB-001 This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canad 1. Characteristics apply to both M9514A and M9521A. M9514A front panel PCIe For connecting ASM to an external computer or another chassis Clock External clock In/Out Port1 Port6 Multi-purpose synchronization and trigger ports MultiFrame Synchronizes timing signals between interconnected AXIe chassis LAN 10/100/1000 Ethernet

12 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Configuration M9514A AC power configuration The M9514A has a flexible AC power subsystem that can be configured to meet the local power requirements and codes. The chassis can be powered from either single- or three-phase systems but AC power must be as follows: Single-phase: 200 240 VAC (line-line or line-neutral) Three-phase Wye with Neutral: 220/380 240/415 VAC (line-neutral/line-line). Line-line voltages greater than 415 VAC are not supported. Three-phase Delta or Wye (no neutral): 200 240 VAC (lineline) The chassis is supplied with a male IEC 60309 3P+N+E connector and comes preconfigured for a 3-phase Wye with Neutral AC Mains. If a different AC Power line configuration is used, it may need to be re-configured. The following wiring methods are supported: Using an optional, pre-built power cable from Keysight (Y1235A Y1238A) Creating your own power cable using a female IEC 60309 connector (not supplied) and the appropriate male plug Removing the male IEC 60309 connector and installing permanent AC wiring or hardwiring a custom AC power cable to the chassis. See the M9514A Site Preparation and Installation Guide (literature no. M9514A-90007) for more details. Recommended system configuration Configure the Keysight M9514A AXIe chassis, as follows: 1. Include an AXIe System Module; the Keysight M9521A is recommended 2. If you are using PCIe to connect an external computer, configure the chassis connection to the host: To ensure the computer will be able to communicate to the chassis and AXIe modules, see Keysight s tested computer list (5990-7362EN). It is recommended that the computer be configured with at least 8 GB of RAM and a 64-bit OS. Select an appropriate PC interface card for the external computer; the Keysight M9048A is recommended. Select an appropriate cable to connect the computer interface board to the AXIe system module; the Y1202A is recommended to connect the M9048A to the M9521A 3. If the M9536A embedded AXIe controller is used instead of an external computer, it can go into any slot other than slot 7 (it does not replace the ASM). The M9536A must have a BIOS revision of AG14 or greater and 64-bit Windows Embedded Standard 7 operating system (option M9536A-WE6). 4. Select a power cord if required (not required if the chassis is hard-wired) 5. Select rack mount rails and MultiFrame cables as required (check module documentation to determine if MultiFrame cables are supported). 6. Select Filler modules for empty slots Y1202A PCIe Cable M9048A PCIe interface Multi-chassis configuration Multiple M9514A chassis can be cascaded together using the PCIe connectors on the M9514A ASM. The host computer can be either external or embedded, but the M9536A is recommended. Up to three chassis can be connected together and a 64-bit OS and 8 GB RAM are required. M9536A Embedded AXIe Controller Figure 8. M9514A configuration. Desktop or Rack mount PC Second AXIe chassis Power sequencing of multiple chassis can be manged automatically with RJ-45 cables (not included). MultiFrame cables can be used if the AXIe modules being used support this feature. Otherwise, the chassis can be interconnected using the clock in/out and Port1 Port6.

13 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet Hardware Related products Model Description M9514A AXIe chassis: 14-slot 1 M9514A-521 Include AXIe System Module (not installed) M9521A AXIe System Module: dual port x8 PCIe Model M9536A M9048A Description AXIe Embedded Controller PCIe desktop PC Adapter 1. Includes "Getting Started" guide, drivers, documentation, CD and Keysight I/O libraries. AXIe filler modules (Y1221A) and power cord must be ordered separately. Accessories Model Description Y1221A AXIe Filler Module: Single Slot Y1223A AXIe MultiFrame cable: 0.5m length 2 Y1224A AXIe MultiFrame cable: 3m length 2 Y1229A Rail kit for M9514A AXIe Chassis Y1234A Protective cover for M9514A Y1235A Power Cable: 1-phase, No Neutral, 250VAC, NEMA L6-30 Y1236A Power Cable: 3-phase, WYE with neutral, 240/415VAC, IEC 60309 Y1237A Power Cable: 3-phase, DELTA, no Neutral, 120/208VAC, NEMA L15-30 Y1238A Power Cable: 3-phase, WYE with Neutral, 240/415VAC, Stripped End Warranty and Calibration Advantage services: Calibration and warranty Keysight Advantage Services is committed to your success throughout your equipment s lifetime. Warranty 3 Description Included 3-year warranty (return to Keysight), standard R-51B-001-5Z 5-year return to Keysight warranty assurance plan R-51C-001-1CU 1-year onsite warranty assurance plan R-51C-001-3CU 3-year onsite warranty assurance plan 3. Options not available in all countries. 2. Check module documentation to determine if MultiFrame cables are supported.

14 Keysight M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module - Data Sheet mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. PICMG and the PICMG logo, CompactPCI and the CompactPCI logo, AdvancedTCA and the AdvancedTCA logo are US registered trademarks of the PCI Industrial Computers Manufacturers Group. PCIe and PCI EXPRESS are registered trademarks and/or service marks of PCI-SIG. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.keysight.com/find/modular www.keysight.com/find/m9514a For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. Keysight Technologies, 2014 Published in USA, August 4, 2014 5991-3908EN www.keysight.com